UNIT CONTROL BOX — Access to this component is through the doors marked ELECTRICAL SECTION on the condenser end of the unit. ECONOMIZER DAMPER MOTORS — The economizer motors are located in the return air section. Access to the motors is through the doors labelled FAN SECTION on the each side of the unit. RETURN-AIR FILTERS — Access to these filters is through the door marked FILTER SECTION on the right side of the unit. CONDENSER FANS AND FAN MOTORS — Remove the wire fan guard on top of the unit to gain access to the condenser fans and motors. Fig. 43 — Door Latch Cleaning — Inspect unit at the beginning of each heating and cooling season and during each season as operating conditions may require. Clean condenser coil with a vacuum cleaner, fresh water, compressed air, or a bristle brush (not wire). Coil cleaning should be a part of the planned maintenance program. Clean evaporator coil with a stiff bristle brush (not wire), vacuum cleaner, or compressed air. Check and clean condensate drain annually at the start of the cooling season. Replace return-air filters at the start of each heating and cooling season or as often as necessary during each season, depending on operating conditions. See Table 1 for filter types, quantities, and sizes. 1. Remove economizer outdoor-air filters from the hoods by removing the filter retainers. 2. Clean filters with steam or hot water and mild detergent. 3. Reinstall filters in hoods after cleaning. Never replace cleanable filters with throwaway filters. latched for easy opening. Remove screws to remove inner panels. Outer panels can be held open for service and inspection by using a door retainer on each panel. Remove bottom pin from door retainer assembly, swing retainer out horizontally, and engage pin in one of the retainer ears in the hinge assembly. COMPRESSORS — The oil pump end (compressor access) of each compressor is readily accessible from sides of unit as shown in Fig. 44. Access the motor end of the compressor through the condenser end of the unit or by removing compressor. LIQUID SERVICE VALVES, SOLENOID VALVES, FILTER DRIERS, AND SIGHT GLASSES — These components are located in the inside corner of the condenser section on the right-hand side of the unit. Filter driers are replaceable-core type. See Fig. 44. EVAPORATOR-FAN MOTORS, PULLEYS, AND BELTS — Access to these components is through the 2 doors labeled FAN SECTION on each side of the unit. POWER EXHAUST MOTORS, PULLEYS, AND BELTS — Access to these components is through the doors at the return air end of the unit. Fig. 44 — Access Locations (50MP70M Unit Shown) 43