Table of corresponding 4291B vs. E4991A GPIB commands
Table of Corresponding GPIB Commands
4291B feature
Selects the fixture compensation short standard.
4291B GPIB command
SENS:CORR2:CKIT:STAN2
E4991A GPIB command
SENS:CORR2:CKIT:LIST on
page 440
(However, cannot choose open/short
alone.)
Enters the inductance value of the LOAD standard that
is used in LOAD compensation.
SENS:CORR2:CKIT:STAN3:L
None (No concept of the load
compensation function.)
Enters the resistance value of the LOAD standard that is SENS:CORR2:CKIT:STAN3:R
used in LOAD compensation.
Selects the fixture compensation load standard.
SENS:CORR2:CKIT:STAN3
Selects the load standard used for the dielectric material SENS:CORR2:CKIT2
test fixture compensation.
The following command is used to
choose a calibration kit in a dielectric
material measurement.
SENS:CORR1:CKIT on page 420
Defines the label of the user-modified compensation kit SENS:CORR2:CKIT2:LAB
for the permittivity measurement.
None
Stores the user-modified compensation kit for the
permittivity measurement into memory.
SENS:CORR2:CKIT2:SAVE
None (However, can save a user-defined
load standard value in the state file.)
Enters the relative permittivity value of the LOAD
standard that is used in LOAD compensation for the
permittivity measurement.
SENS:CORR2:CKIT2:STAN6:PRE
SENS:CORR1:CKIT:STAN7:PRE on
page 435
Enters the relative dielectric loss index value of
user-modified LOAD standard that is used in LOAD
compensation for the permittivity measurement.
SENS:CORR2:CKIT2:STAN6:PLF
SENS:CORR1:CKIT:STAN7:PLF on
page 434
Enters the thickness value of user-modified LOAD
standard that is used in LOAD compensation for the
permittivity measurement.
SENS:CORR2:CKIT2:STAN6:THIC
SENS:CORR1:CKIT:STAN7:THIC
on page 436
Measures the standard for the fixture compensation.
SENS:CORR2:COLL
SENS:CORR2:COLL on page 449
Selects the frequency points where the correction data is SENS:CORR2:COLL:FPO
corrected.
SENS:CORR2:COLL:FPO on
page 450
Calculates the fixture compensation coefficients and
stores the coefficients.
SENS:CORR2:COLL:SAVE
SENS:CORR2:COLL:SAVE on
page 451
Sets the OPEN fixture compensation ON or OFF.
SENS:CORR2:OPEN
SENS:CORR2:COLL:OPEN on
page 451
Sets the SHORT fixture compensation ON or OFF.
SENS:CORR2:SHOR
SENS:CORR2:COLL:SHOR on
page 452
Sets the LOAD fixture compensation ON or OFF.
SENS:CORR2:LOAD
None (No concept of the load
compensation function.)
Defines the center frequency value of the stimulus
range.
SENS:FREQ:CENT
FREQ:CENT on page 376
Sets the frequency center value to the difference value
between the marker and the delta marker values.
None
Sets the frequency center value of the marker.
CALC{1-5}:MARK:SET on page 336
Searches for a peak using the marker and then changes
the CENTER to the frequency value of that peak.
Combines the following commands in
execution.
CALC{1-5}:MARK:FUNC:EXEC on
page 321
CALC{1-5}:MARK:SET on page 336
Selects the sweep type.
SENS:FREQ:MODE
594
SWE:TYPE on page 515
Appendix D