40RM 40RMQ 40RMS Packaged Air-Handling Units 50/60 Hz Installation, Start-Up and Service Instructions CONTENTS Page SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . 1 PRE-INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . 1 Moving and Storage . . . . . . . . . . . . . . . . . . . . . . . . 1 Rigging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-23 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Uncrating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Unit Positioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Unit Isolation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Refrigerant and Chilled Water Piping Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Refrigerant Piping . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Chilled Water Piping . . . . . . . . . . . . . . . . . . . . . . . 17 Condensate Drain . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Fan Motors and Drives . . . . . . . . . . . . . . . . . . . . . 18 Power Supply and Wiring . . . . . . . . . . . . . . . . . . . 19 Connecting Ductwork . . . . . . . . . . . . . . . . . . . . . . 22 Return-Air Filters . . . . . . . . . . . . . . . . . . . . . . . . . . 22 START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 SERVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23-39 Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Fan Motor Lubrication . . . . . . . . . . . . . . . . . . . . . . 23 Fan Shaft Bearings . . . . . . . . . . . . . . . . . . . . . . . . . 23 Centering Fan Wheel . . . . . . . . . . . . . . . . . . . . . . . 24 Fan Shaft Position Adjustment . . . . . . . . . . . . . . 24 Individual Fan Wheel Adjustment . . . . . . . . . . . 24 Fan Belts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Fan Rotation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Fan Pulley Alignment . . . . . . . . . . . . . . . . . . . . . . . 25 Pulley and Drive Adjustment . . . . . . . . . . . . . . . . 25 Condensate Drains . . . . . . . . . . . . . . . . . . . . . . . . . 25 Return-Air Filters . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Chilled Water Coil Freeze Protection . . . . . . . . 25 Coil Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Cleaning Cooling Coil . . . . . . . . . . . . . . . . . . . . . . 25 Cleaning Insulation . . . . . . . . . . . . . . . . . . . . . . . . 25 Replacing Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 START-UP CHECKLIST . . . . . . . . . . . . . . . . CL-1,CL-2 SAFETY CONSIDERATIONS Installing, starting up, and servicing this equipment can be hazardous due to system pressures, electrical components and equipment location (elevated structures, etc.). Only trained, qualified installers and service mechanics should install, start up, and service this equipment. Untrained personnel can perform basic maintenance functions such as cleaning coils, and cleaning and replacing filters. All other operations should be performed by trained service personnel. When working on the equipment, observe precautions in the literature and on tags, stickers, and labels attached to the equipment. • Follow all safety codes. • Wear safety glasses and work gloves. • Use care in handling, rigging, and setting bulky equipment. Be sure all power to equipment is shut off before performing maintenance or service. More than one disconnect may be present. PRE-INSTALLATION Moving and Storage — To transfer unit from truck to storage site, use a fork truck. Do not stack units more than 2 high during storage. If unit is to be stored for more than 2 weeks before installation, choose a level, dry storage site free from vibration. Do not remove plastic wrap or skid from unit until final installation. Rigging — All 40RM Series units can be rigged by using the shipping skid. Units are shipped fully assembled. Do not remove shipping skids or protective covering until unit is ready for final placement; damage to bottom panels can result. Use slings and spreader bars as applicable to lift unit. INSTALLATION General — Allow 21⁄2 ft at front and side of unit for service clearance and airflow. For units equipped with an economizer, refer to the accessory installation instructions for additional clearance requirements. Be sure floor, wall, or ceiling can support unit weight (Tables 1A-1F). See Fig. 1A-1C for dimensions. Uncrating — Move unit as near as possible to final location before removing shipping skid. Remove metal banding, top skid, and plastic wrap. Examine unit for shipping damage. If shipping damage is evident, file claim with transportation agency. Remove base skid just prior to actual installation. Check nameplate information against available power supply and model number description in Fig. 2. Accessories — Refer to instructions shipped with each accessory for specific information. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 4 PC 111 Catalog No. 534-053 Printed in U.S.A. Form 40RM-9SI Pg 1 11-95 Replaces: 40RM-1SI Tab 3c 2e Table 1A — 40RM Physical Data, English UNIT 40RM NOMINAL CAPACITY (Tons) OPERATING WEIGHT (lb) Base Unit with TXV Plenum FANS Qty...Diam. (in.) Nominal Airflow (cfm) Airflow Range (cfm) Nominal Motor Hp (Standard Motor) 208/230-1-60 208/230-3-60 and 460-3-60 575-3-60 230-3-50, 400-3-50 Motor Speed (rpm) 208/230-1-60 208/230-3-60 and 460-3-60 575-3-60 230-3-50, 400-3-50 REFRIGERANT Operating charge (lb) (approx per circuit)* DIRECT-EXPANSION COIL Max Working Pressure (psig) Face Area (sq ft) No. of Splits No. of Circuits per Split Split Type...Percentage Rows...Fins/in. STEAM COIL Max Working Pressure (psig at 400 F) Total Face Area (sq ft) Rows...Fins/in. HOT WATER COIL Max Working Pressure (psig) Total Face Area (sq ft) Rows...Fins/in. Water Volume (gal) (ft3) PIPING CONNECTIONS, Quantity...Size (in.) DX Coil — Suction (ODF) DX Coil — Liquid Refrigerant (ODF) Steam Coil, In (MPT) Steam Coil, Out (MPT) Hot Water Coil, In (MPT) Hot Water Coil, Out (MPT) Condensate (PVC) FILTERS Quantity...Size (in.) Access Location 007 6 008 71⁄2 012 10 014 121⁄2 016 15 024 20 028 25 034 30 381 97 385 97 405 97 670 140 685 140 690 140 1020 180 1030 180 1...15 2400 18003000 1...15 3000 22503750 1...15 4000 30005000 2...15 5000 37506250 2...15 6000 45007500 2...15 8,000 6,00010,000 2...18 10,000 7,50012,500 2...18 12,000 9,00015,000 1.3 2.4 1.0 2.4 2.4 2.4 2.0 2.4 — 2.4 2.0 2.9 — 2.9 3.0 2.9 — 3.7 3.0 2.9 — 5.0 5.0 5.0 — 7.5 7.5 7.5 — 10.0 10.0 10.0 1725 1725 1725 1425 1725 1725 1725 1425 — 1725 1725 1425 — 1725 1725 1425 — 1745 1745 1425 — 1745 1755 1425 — 1745 1755 1425 3.0 3.0 1.5/1.5 2.0/2.0 3.5/3.5 4.5/4.5 5.0/5.0 6.67 1 12 — 3...15 Enhanced Copper Tubes, Aluminum Sine-Wave Fins 435 8.33 10.0 13.25 17.67 19.88 24.86 1 2 2 2 2 2 15 9 9 12 13 15 — Face...50/50 3...15 3...17 3...15 3...15 3...17 3...15 29.83 2 18 6.67 1...9 6.67 1...9 6.67 1...9 13.33 1...10 175 13.33 1...10 13.33 1...10 15.0 1...10 15.0 1...10 6.67 2...8.5 6.67 2...8.5 6.67 2...8.5 13.33 2...8.5 150 13.33 2...8.5 13.33 2...8.5 15.0 2...12.5 15.0 2...12.5 8.3 1.1 — 1725 1725 1425 R-22 2.5/2.5 13.9 1.85 1...11⁄8 1...11⁄8 1...5⁄8 1...21⁄2 1...11⁄2 1...11⁄2 1...11⁄2 2...11⁄8 2...11⁄8 2...5⁄8 1...21⁄2 1...11⁄2 1...11⁄2 1...2 1...11⁄2 1...2 1...11⁄4 ODM/1 IDF Throwaway — Factory Supplied 4...16 x 20 x 2 4...16 x 24 x 2 4...16 x 24 x 2 Either Side LEGEND TXV — Thermostatic Expansion Valve *Units are shipped without refrigerant charge. 2 2...11⁄8 2...11⁄8 3...15 14.3 1.90 2...13⁄8 2...13⁄8 4...20 x 24 x 2 4...20 x 25 x 2 Table 1B — 40RMQ Physical Data, English UNIT 40RMQ NOMINAL CAPACITY (Tons) OPERATING WEIGHT (lb) Base Unit with TXV Plenum FANS Qty...Diam. (in.) Nominal Airflow (cfm) Airflow Range (cfm) Nominal Motor Hp (Standard Motor) 208/230-1-60 208/230-3-60 and 460-3-60 575-3-60 230-3-50, 400-3-50 Motor Speed (rpm) 208/230-1-60 208/230-3-60 and 460-3-60 575-3-60 230-3-50, 400-3-50 REFRIGERANT Operating charge (lb) (approx per circuit)* DIRECT-EXPANSION COIL Max Working Pressure (psig) Face Area (sq ft) No. of Splits No. of Circuits per Split Split Type...Percentage Rows...Fins/in. STEAM COIL Max Working Pressure (psig at 400 F) Total Face Area (sq ft) Rows...Fins/in. HOT WATER COIL Max Working Pressure (psig) Total Face Area (sq ft) Rows...Fins/in. Water Volume (gal) (ft3) PIPING CONNECTIONS, Quantity...Size (in.) DX Coil — Suction (ODF) DX Coil — Liquid Refrigerant (ODF) Steam Coil, In (MPT) Steam Coil, Out (MPT) Hot Water Coil, In (MPT) Hot Water Coil, Out (MPT) Condensate (PVC) FILTERS Quantity...Size (in.) Access Location 008 71⁄2 012 10 016 15 385 97 427 97 713 140 1...15 3000 2250-3750 1...15 4000 3000-5000 2...15 6000 4500-7500 2.4 2.4 2.0 2.4 — 2.4 2.0 2.9 — 3.7 3.0 2.9 1725 1725 1725 1425 — 1725 1725 1425 R-22 2.0/2.0 — 1725 1725 1425 3.0 3.0/3.0 Enhanced Copper Tubes, Aluminum Sine-Wave Fins 435 8.33 10.0 17.67 1 2 2 15 9 16 — Face...50/50 3...15 4...15 4...15 6.67 1...9 175 6.67 1...9 13.33 1...10 6.67 2...8.5 150 6.67 2...8.5 13.33 2...8.5 8.3 1.1 1...11⁄8 1...5⁄8 1...21⁄2 1...11⁄2 1...11⁄2 1...11⁄2 LEGEND TXV — Thermostatic Expansion Valve *Units are shipped without refrigerant charge. 3 13.9 1.85 2...11⁄8 2...5⁄8 2...11⁄8 2...5⁄8 1...21⁄2 1...11⁄2 1...11⁄2 1...2 1...11⁄2 1...2 1...11⁄4 ODM/1 IDF Throwaway — Factory Supplied 4...16 x 20 x 2 4...16 x 24 x 2 4...16 x 24 x 2 Either Side Table 1C — 40RMS Physical Data, English UNIT 40RMS 008 010 012 014 016 024 028 034 NOMINAL CAPACITY (Tons) 71⁄2 8 1 ⁄2 10 121⁄2 15 20 25 30 OPERATING WEIGHT (lb) Base Unit 390 391 391 661 677 683 1035 1042 Plenum 97 97 97 140 140 140 180 180 FANS Qty...Diam. (in.) 1...15 1...15 1...15 2...15 2...15 2...15 2...18 2...18 Nominal Airflow (cfm) 3000 3400 4000 5000 6000 8000 10,000 12,000 Airflow Range (cfm) 2250-3750 2250-4250 3000-5000 3750-6250 4500-7500 6000-10,000 7500-12,500 9000-15,000 Nominal Motor Hp (Standard Motor) 208/230-1-60 2.4 2.4 — — — — — — 208/230-3-60 and 460-3-60 2.4 2.4 2.4 2.9 3.7 5.0 7.5 10.0 575-3-60 2.0 2.0 2.0 3.0 3.0 5.0 7.5 10.0 230-3-50 and 400-3-50 2.4 2.4 2.9 2.9 2.9 5.0 7.5 10.0 Motor Speed (rpm) 208/230-1-60 1725 1725 — — — — — — 208/230-3-60 and 460-3-60 1725 1725 1725 1725 1725 1745 1745 1745 575-3-60 1725 1725 1725 1725 1725 1745 1755 1755 230-3-50 and 400-3-50 1425 1425 1425 1425 1425 1425 1425 1425 CHILLED WATER COIL Enhanced Copper Tubes, Aluminum Sine-Wave Fins Max Working Pressure 435 (psig) Face Area (sq ft) — Upper 8.3 9.0 4.9 8.3 8.3 11.0 12.4 15.5 Face Area (sq ft) — Lower — — 4.9 5.5 8.3 8.3 12.4 12.4 Rows...Fins/in. 3...15 STEAM COIL Max Working Pressure 175 (psig at 400 F) Total Face Area (sq ft) 6.67 6.67 6.67 13.33 13.33 13.33 15.0 15.0 Rows...Fins/in. 1...9 1...9 1...9 1...10 1...10 1...10 1...10 1...10 HOT WATER COIL Max Working Pressure 150 (in. wg) Total Face Area (sq ft) 6.67 6.67 6.67 13.33 13.33 13.33 15.0 15.0 Rows...Fins/in. 2...8.5 2...8.5 2...8.5 2...8.5 2...8.5 2...8.5 2...12.5 2...12.5 Water Volume (gal) 8.3 13.9 14.3 (ft3) 1.1 1.85 1.90 PIPING CONNECTIONS, Quantity...Size (in.) Chilled Water — In 1...13⁄8 ODF 1...13⁄8 ODF 2...13⁄8 ODF 2...13⁄8 ODM 2...13⁄8 ODM 2...13⁄8 ODM 2...21⁄8 ODM 2...21⁄8 ODM Chilled Water — Out 1...13⁄8 ODF 1...13⁄8 ODF 2...13⁄8 ODF 2...13⁄8 ODM 2...13⁄8 ODM 2...13⁄8 ODM 2...21⁄8 ODM 2...21⁄8 ODM Steam Coil, In (MPT) 1...21⁄2 1...21⁄2 Steam Coil, Out (MPT) 1...11⁄2 1...11⁄2 Hot Water Coil, In (MPT) 1...11⁄2 1...11⁄2 1...2 Hot Water Coil, Out (MPT) 1...11⁄2 1...11⁄2 1...2 Condensate (PVC) 1...11⁄4 ODM/1 IDF FILTERS Throwaway — Factory Supplied 4...16 x 20 x 2 4...20 x 24 x 2 Quantity...Size (in.) 4...16 x 24 x 2 4...16 x 24 x 2 4...20 x 25 x 2 Access Location Either Side 4 Table 1D — 40RM Physical Data, SI UNIT 40RM 007 008 012 014 016 024 028 034 NOMINAL CAPACITY (kW) 21 26 35 43 52 70 87 105 OPERATING WEIGHT (kg) Base Unit with TXV 173 175 184 304 311 313 463 467 Plenum 44 44 44 63 63 63 82 82 FANS Qty...Diam. (mm) 1...381 1...381 1...381 2...381 2...381 2...381 2...457 2...457 Nominal Airflow (L/s) 1133 1604 1888 2360 2831 3775 4719 5663 Airflow Range (L/s) 850-1416 1203-2006 1416-2360 1770-2949 2124-3539 2831-4719 3539-5899 4247-7079 Nominal Motor kW (Standard Motor) 208/230-1-60 0.97 1.79 — — — — — — 208/230-3-60 and 460-3-60 1.79 1.79 1.79 2.16 2.76 3.73 5.60 7.46 575-3-60 0.75 1.49 1.49 2.24 2.24 3.73 5.60 7.46 230-3-50, 400-3-50 1.79 1.79 2.16 2.16 2.16 3.73 5.60 7.46 Motor Speed (r/s) 208/230-1-60 28.8 28.8 — — — — — — 208/230-3-60 and 460-3-60 28.8 28.8 28.8 28.8 28.8 29.1 29.1 29.1 575-3-60 28.8 28.8 28.8 28.8 28.8 29.1 29.3 29.3 230-3-50, 400-3-50 23.8 23.8 23.8 23.8 23.8 23.8 23.8 23.8 REFRIGERANT R-22 Operating charge (kg) 1.36 1.36 0.68/0.68 0.90/0.90 1.13/1.13 1.59/1.59 2.04/2.04 2.27/2.27 (approx per circuit)* DIRECT-EXPANSION COIL Enhanced Copper Tubes, Aluminum Sine-Wave Fins Max Working Pressure (kPag) 2999 Face Area (sq m) 0.62 0.77 0.93 0.93 1.64 1.85 2.30 2.77 No. of Splits 1 1 2 2 2 2 2 2 No. of Circuits per Split 12 15 9 9 12 13 15 18 Split Type...Percentage — — Face...50/50 Rows...Fins/m 3...591 3...591 3...670 3...591 3...591 3...670 3...591 3...591 STEAM COIL Max Working Pressure (kPag at 204.4 C) 1207 Total Face Area (sq m) 0.62 0.62 0.62 1.24 1.24 1.24 1.39 1.39 Rows...Fins/m 1...355 1...355 1...355 1...394 1...394 1...394 1...394 1...394 HOT WATER COIL Max Working Pressure (kPag) 1034 Total Face Area (sq m) 0.62 0.62 0.62 1.24 1.24 1.24 1.39 1.39 Rows...Fins/m 2...335 2...335 2...335 2...335 2...335 2...335 2...493 2...493 Water Volume (L) 31.4 52.6 54.1 (m3) 0.031 0.052 0.054 PIPING CONNECTIONS, Quantity...Size (in.) DX Coil — Suction (ODF) 1...11⁄8 1...11⁄8 2...11⁄8 2...11⁄8 2...11⁄8 2...11⁄8 2...13⁄8 2...13⁄8 DX Coil — Liquid Refrigerant (ODF) 1...5⁄8 2...5⁄8 Steam Coil, In (MPT) 1...21⁄2 1...21⁄2 Steam Coil, Out (MPT) 1...11⁄2 1...11⁄2 Hot Water Coil, In (MPT) 1...11⁄2 1...11⁄2 1...2 Hot Water Coil, Out (MPT) 1...11⁄2 1...11⁄2 1...2 Condensate (PVC) 1...11⁄4 ODM/1 IDF FILTERS Throwaway — Factory Supplied 4...406 x 508 x 51 4...508 x 610 x 51 Quantity...Size 4...406 x 610 x 51 4...406 x 610 x 51 4...508 x 635 x 51 Access Location Either Side LEGEND TXV — Thermostatic Expansion Valve *Units are shipped without refrigerant charge. 5 Table 1E — 40RMQ Physical Data, SI UNIT 40RMQ NOMINAL CAPACITY (kW) OPERATING WEIGHT (kg) Base Unit with TXV Plenum FANS Qty...Diam. (mm) Nominal Airflow (L/s) Airflow Range (L/s) Nominal Motor kW (Standard Motor) 208/230-1-60 208/230-3-60 and 460-3-60 575-3-60 230-3-50, 400-3-50 Motor Speed (r/s) 208/230-1-60 208/230-3-60 and 460-3-60 575-3-60 230-3-50, 400-3-50 REFRIGERANT Operating charge (kg) (approx per circuit)* DIRECT-EXPANSION COIL Max Working Pressure (kPag) Face Area (sq m) No. of Splits No. of Circuits per Split Split Type...Percentage Rows...Fins/m STEAM COIL Max Working Pressure (kPag at 204.4 C) Total Face Area (sq m) Rows...Fins/m HOT WATER COIL Max Working Pressure (kPag) Total Face Area (sq m) Rows...Fins/m Water Volume (L) (m3) PIPING CONNECTIONS, Quantity...Size (in.) DX Coil — Suction (ODF) DX Coil — Liquid Refrigerant (ODF) Steam Coil, In (MPT) Steam Coil, Out (MPT) Hot Water Coil, In (MPT) Hot Water Coil, Out (MPT) Condensate (Male PVC) FILTERS Quantity...Size Access Location 008 26 012 35 016 52 175 44 194 44 323 63 1...381 1604 1203-2006 1...381 1888 1416-2360 2...381 2831 2124-3539 1.79 1.79 1.49 1.79 — 1.79 1.49 2.16 — 2.76 2.24 2.16 28.8 28.8 28.8 23.8 — 28.8 28.8 23.8 R-22 — 28.8 28.8 23.8 1.36 0.91/0.91 1.36/1.36 2999 0.93 2 9 0.77 1 15 — 3...591 1.64 2 16 4...591 4...591 0.62 1...355 1207 0.62 1...355 1.24 1...394 0.62 2...335 1034 0.62 2...335 1.24 2...335 Face...50/50 31.4 0.031 1...11⁄8 1...5⁄8 1...21⁄2 1...11⁄2 1...11⁄2 1...11⁄2 52.6 0.052 2...11⁄8 2...5⁄8 2...11⁄8 2...5⁄8 1...21⁄2 1...11⁄2 1...11⁄2 1...2 1...11⁄2 1...2 1...11⁄4 ODM/1 IDF Throwaway — Factory Supplied 4...406 x 508 x 51 4...406 x 610 x 51 4...406 x 610 x 51 Either Side LEGEND TXV — Thermostatic Expansion Valve *Units are shipped without refrigerant charge. 6 Table 1F — 40RMS Physical Data, SI UNIT 40RMS NOMINAL CAPACITY (kW) OPERATING WEIGHT (kg) Base Unit Plenum FANS Qty...Diam. (mm) Nominal Airflow (L/s) 008 26 010 29 012 35 014 43 016 52 024 70 028 87 034 105 177 44 177 44 177 44 300 63 307 63 310 63 469 82 473 82 1...381 1416 10621770 1...381 1605 12042006 1...381 1888 14162360 2...381 2360 17702949 2...381 2831 21243539 2...381 3775 28314719 2...457 4719 35395899 2...457 5663 42477079 Airflow Range (L/s) Nominal Motor kW (Standard Motor) 208/230-1-60 1.79 1.79 — — — — — — 208/230-3-60, 460-3-60 1.79 1.79 1.79 1.79 2.76 3.73 5.60 7.46 575-3-60 1.49 1.49 1.49 1.49 2.24 3.73 5.60 7.46 230-3-50, 400-3-50 1.79 1.79 2.16 2.16 2.16 3.73 5.60 7.46 Motor Speed (r/s) 208/230-1-60 28.8 28.8 — — — — — — 208/230-3-60, 460-3-60 28.8 28.8 28.8 28.8 28.8 29.1 29.1 29.1 575-3-60 28.8 28.8 28.8 28.8 28.8 29.1 29.3 29.3 230-3-50, 400-3-50 23.8 23.8 23.8 23.8 23.8 23.8 23.8 23.8 CHILLED WATER COIL Max Working Pressure 2999 (kPag) Face Area (sq m) — Upper 0.77 0.84 0.91 0.77 0.77 1.02 1.15 1.44 Face Area (sq m) — Lower — — — 0.51 0.77 0.77 1.15 1.15 Rows...Fins/m 3...591 3...591 3...591 3...591 3...591 3...591 3...591 3...591 STEAM COIL Max Working Pressure 1207 (kPag at 204.4 C) Total Face Area (sq m) 0.62 0.62 0.62 1.24 1.24 1.24 1.39 1.39 Rows...Fins/m 1...355 1...355 1...355 1...355 1...394 1...394 1...394 1...394 HOT WATER COIL Max Working Pressure 1034 (kPag) Total Face Area (sq m) 0.62 0.62 0.62 1.24 1.24 1.24 1.39 1.39 Rows...Fins/m 2...335 2...335 2...335 2...335 2...335 2...335 2...493 2...493 Water Volume (L) 31.4 52.6 54.1 (m3) 0.031 0.052 0.054 PIPING CONNECTIONS, Quantity...Size (in.) Chilled Water — In 1...13⁄8 ODF 1...13⁄8 ODF 2...13⁄8 ODF 2...13⁄8 ODM 2...13⁄8 ODM 2...13⁄8 ODM 2...21⁄8 ODM 2...21⁄8 ODM Chilled Water — Out 1...13⁄8 ODF 1...13⁄8 ODF 2...13⁄8 ODF 2...13⁄8 ODM 2...13⁄8 ODM 2...13⁄8 ODM 2...21⁄8 ODM 2...21⁄8 ODM 1...21⁄2 Steam Coil, In (MPT) 1...21⁄2 Steam Coil, Out (MPT) 1...11⁄2 1...11⁄2 Hot Water Coil, In (MPT) 1...11⁄2 1...11⁄2 1...2 1...11⁄2 1...2 Hot Water Coil, Out (MPT) 1...11⁄2 Condensate (PVC) 1...11⁄4 ODM/1 IDF FILTERS Throwaway — Factory Supplied 4...406 x 508 x 51 4...508 x 610 x 51 Quantity...Size (mm) 4...406 x 610 x 51 4...406 x 610 x 51 4...508 x 635 x 51 Access Location Either Side 7 TXV — Thermostatic Expansion Valve NOTES: 1. Dimensions in [ ] are in millimeters. 2. Direction of airflow. 3. Recommended clearance: • Rear: 3 in. (76 mm ) • Front: 2 ft, 6 in. (762 mm) • Right Side: 2 ft, 6 in. (762 mm) • Left Side: 2 ft, 6 in. (762 mm) • Local codes or jurisdiction may prevail. 4. Liquid piping not supplied by Carrier. 5. Duct flange is factory supplied and field installed. 6. 40RMS units may require alternate or additional field-fabricated piping access holes. UNIT 40RM007 40RM008 40RM012 40RMQ008 40RMQ012 40RMS008 40RMS010 40RMS012 Fig. 1A — Dimensions — Sizes 007-012 8 UNIT WEIGHT lb (kg) 381 (173) 385 (175) 405 (184) 385 (175) 427 (194) 390 (177) 391 (177) 391 (177) TXV — Thermostatic Expansion Valve NOTES: 1. Dimensions in [ ] are in millimeters. 2. Direction of airflow. 3. Recommended clearance: • Rear: 3 in. (76 mm) • Front: 2 ft, 6 in. (762 mm) • Right Side: 2 ft, 6 in. (762 mm) • Left Side: 2 ft, 6 in. (762 mm) • Local codes or jurisdiction may prevail. 4. Liquid piping not supplied by Carrier. 5. Duct flange is factory supplied and field installed. 6. 40RMQ016 and 40RMS units may require alternate or additional field-fabricated piping access holes. UNIT 40RM014 40RM016 40RM024 40RMQ016 40RMS014 40RMS016 40RMS024 Fig. 1B — Dimensions — Sizes 014-024 9 UNIT WEIGHT lb (kg) 670 (304) 685 (311) 690 (313) 713 (323) 661 (300) 677 (307) 683 (310) UNIT WEIGHT lb (kg) 40RM028 1020 (463) 40RM034 1030 (467) 40RMS028 1035 (469) 40RMS034 1042 (473) UNIT TXV — Thermostatic Expansion Valve NOTES: 1. Dimensions in [ ] are in millimeters. 2. Direction of airflow. 3. Recommended clearance: • Rear: 3 in. (76 mm) • Front: 2 ft, 6 in. (762 mm) • Right Side: 2 ft, 6 in. (762 mm) • Left Side: 2 ft, 6 in. (762 mm) • Local codes or jurisdiction may prevail. 4. Liquid piping not supplied by Carrier. 5. Duct flange is factory supplied and field installed. 6. 40RMS units may require alternate or additional field-fabricated piping access holes. Fig. 1C — Dimensions — Sizes 028,034 10 *YC and WD option codes for all 034 size units and 008, 010 units with 208/230-1-60 power designate standard motor and high-static drive. NOTE: See the following table for the sizes available for each unit. UNIT 40RM 40RMQ 40RMS 007 X 008 X X X 010 X 012 X X X 014 X X 016 X X X 024 X 028 X 034 X X X X Fig. 2 — Model Number Nomenclature Unit Positioning — The unit can be mounted on the floor for vertical application with return air entering the face of the unit and supply air discharging vertically through the top of the unit. The unit can also be applied in a horizontal arrangement with return air entering horizontally and the supply air discharging horizontally. When applying the unit in a horizontal arrangement, ensure the condensate drain pan is located at the bottom center of the unit for adequate condensate disposal. See Fig. 3 for condensate connections for each unit position. Typical positioning and alternate return air locations are shown in Fig. 3. Alternate return air locations can be used by moving the unit panel from the alternate return air location to the standard return air location. LEGEND Accessory Line Alternate Air Intake and Discharge Air Intake and Discharge Fig. 3 — Typical Unit Positioning IMPORTANT: Do NOT attempt to install unit with return air entering top panel of unit. Condensate will not drain from unit. 11 Unit Isolation — Where extremely quiet operation is essential, install isolators between floor and base of unit, or between ceiling and top section of unit. Be sure that unit is level and adequately supported. Use channels at front and sides of unit for reference points when leveling. Refrigerant Piping — See Tables 1A, 1B, 1D, 1E for refrigerant pipe connection sizes. For ease in brazing, it is recommended that all internal solder joints be made before unit is placed in final position. The 40RM and 40RMQ direct-expansion units have internal factory-installed thermostatic expansion valves (TXVs), distributors, and nozzles for use with R-22. See Table 2 for part numbers. Knockouts are provided in the unit corner posts for 40RM and 40RMQ008 and 012 refrigerant piping. The 40RMQ016 unit requires additional field-fabricated piping access holes. See Fig. 4, which also lists recommended knockouts and access holes to use for each 40RM and 40RMQ unit size. Recommended fittings are listed in Table 3. The sensor bulb capillary tubes must be routed from the TXVs inside the unit through one of the piping access holes. Clamp the TXV sensor bulb on a vertical portion of the suction line, outside the unit. See Fig. 5. Refrigerant and Chilled Water Piping Access — The 40RM Series units come with standard knockouts for refrigerant and chilled water piping. These knockouts are located on both sides of the unit for installation flexibility. The standard knockouts provide sufficient access to the unit’s coils for all 40RM and some 40RMQ units, however, for 40RMQ016 and 40RMS units, additional holes must be field-fabricated to accommodate the piping. See Fig. 4 for the positions and dimensions of the additional access holes required for these units, including hole diameters and drilling dimensions. Recommended access hole use is also listed for all units. Note that Fig. 4 shows the access holes on the control-box side of the unit; this is the side of the unit with the coil headers, so it is used most often for piping access. UNIT USE HOLE NUMBERS 40RM007,008 40RMQ008 40RM012-034 40RMQ012 40RMS008-012 40RMS014-024 40RMQ016 40RMS028,034 1, 3 FIELD-FABRICATED HOLE DIAMETERS, in. (mm) No. 5 No. 6 No. 7 No. 8 A FIELD-FABRICATED HOLE POSITION DIMENSIONS, in. (mm) B C D — — — — — — — — 1, 2, 3, 4 — — — — — — — — 4, 5 4, 5, 6, 7 3*, 5, 6, 7 5, 6, 7, 8 1 ⁄ (44.5) 13⁄4 (44.5) 11⁄8 (28.6) 21⁄2 (63.5) — 13⁄4 (44.5) 11⁄8 (28.6) 21⁄2 (63.5) — 13⁄4 (44.5) 13⁄4 (44.5) 21⁄2 (63.5) — — — 21⁄2 (63.5) 6.25 (158.8) 3.0 (76.2) 3.25 (82.6) 6.0 (152.4) — 6.0 (152.4) 6.125 (155.6) 9.625 (244.5) — 10.5 (266.7) 10.38 (263.7) 13.38 (339.9) — — — 17.0 (431.8) 34 *Must be enlarged from 11⁄8 in. to 13⁄4 inches. NOTE: Access hole knockouts 1-4 are factory-supplied. Fig. 4 — Refrigerant and Chilled Water Piping Access Holes 12 IMPORTANT: Never attach the sensor to the suction manifold. Do NOT mount the sensor on a trapped portion of the suction line. 40RM Series evaporator coils have a face-split design. Ensure that lower circuit of coil is first on/last off when connected to the condensing unit and/or system controls. See Fig. 6. External TXV equalizer connections are provided and factorybrazed into the coil suction manifolds. If suction line must be horizontal, clamp bulb to suction line at least 45 degrees above bottom, at approximately the 4 o’clock or 8 o’clock position. See Fig. 7. NOTE: The 40RMQ units are supplied with factory-installed thermostatic expansion valves and check valve bypasses. No extra piping connections or kits are required to install the 40RMQ with a 38AQS condensing unit in a heat pump system, however, some field supplied components may be required. See the following two sections. FIRST ON/LAST OFF=B VERTICAL INSTALLATION FIRST ON/LAST OFF=A HORIZONTAL INSTALLATION Fig. 6 — Typical Evaporator Coil Connections (40RM, 40RMQ) LEGEND TXV — Thermostatic Expansion Valve NOTE: Component location arrangement shown for field installation of sight glasses, solenoid valves, filter driers, and TXV sensing bulbs. The TXVs and equalizer lines are factory installed. Fig. 5 — Face-Split Coil Suction and Liquid Line Piping (Typical) LEGEND TXV — Thermostatic Expansion Valve NOTE: The 8 o’clock position is shown above. Fig. 7 — TXV Sensing Bulb Location 13 Table 2 — Factory-Installed Nozzle and Distributor Data UNIT TXV Qty...Part No. DISTRIBUTOR Qty...Part No. 40RM007 40RM008 40RMQ008 40RM012 40RMQ012 40RM014 40RM016 40RMQ016 40RM024 40RM028 40RM034 1...XVE-5 1...SVE-8 1...SVE-8 2...XVE-4 2...XVE-4 2...XVE-5 2...XVE-8 2...SVE-8 2...XVE-10 2...EBSVE-11 2...SVE-15 1...1116 1...1126 1...1657 2...1115 2...1655 2...1115 2...1116 2...1126 2...1116 2...1126 2...1126 FEEDER TUBES PER DISTRIBUTOR* Qty...Size (in.) 12 15 15 9 9 9 12 16 13 15 18 NOZZLE Qty...Part No. 1...E5 1...C6 1...C6 2...E4 2...E4 2...E5 2...E6 2...C6 2...E8 2...C10 2...C12 * Feeder tube size is 1⁄4 in. (6.35 mm). NOTE: Hot gas bypass applications require field-supplied auxiliary side connector. 38AQS008/40RMQ008 HEAT PUMP SYSTEM PIPING — Addition of a liquid solenoid valve (LLSV) is recommended when the piping system length exceeds 75 feet. The LLSV must be a bi-flow type suited for use in heat pump systems. The recommended valve is Sporlan model CB14S2 (5/8-in. ODF, 7/8-in. ODM) available from the Replacement Components Division as part number EF23JS-214. This solenoid valve requires Sporlan part no. MKC-2 coils that must be purchased locally. Wire the solenoid valve in parallel with the compressor contactor coil. The LLSV must be installed at the outdoor unit with the flow arrow pointed toward the outdoor unit (in-flow direction for the heating mode.) LEGEND TXV — Thermostatic Expansion Valve RECOMMENDED FILTER DRIERS* (38AQS012,016/40RMQ SYSTEMS) FILTER DRIER REQUIREMENTS FOR 38AQS012/ 40RMQ012 AND 38AQS016/40RMQ016 HEAT PUMP SYSTEMS — The 38AQS012 and 016 units do not include filter driers. Filter driers must be field-supplied and installed in 38AQS012/40RMQ012 and 38AQS016/ 40RMQ016 systems. The filter driers used with these systems must be bi-flow types suited for use in heat pump applications. The Replacement Component Division part numbers listed in Fig. 8 are recommended and available for field installation. UNIT 38AQS 012 016 LIQUID LINE SIZE (in.) 1⁄2 5⁄8 1⁄2 5⁄8 PART NO. P504-8084S P504-8165S P504-8084S P504-8085S QUANTITY FIGURE REQUIRED REFERENCE 2 1 2 2 A B A A *Available from Carrier Replacement Components Division. Fig. 8 — Filter Drier Requirements — 38AQS012/40RMQ012 and 38AQS016/40RMQ016 Heat Pump Systems 14 Table 3 — Fitting Requirements UNIT ACCESS HOLE NO.* CONNECTION TYPE CIRCUIT 1 Suction — 3 Liquid — 1 Suction — 3 Liquid — 4 Return — 5 Supply — 1 Suction Lower 2 Liquid Lower 3 Liquid Upper 4 Suction Upper 1 Suction Lower 2 Liquid Lower 3 Liquid Upper 4 Suction Upper 1 Suction Lower 2 Liquid Lower 3 Liquid Upper 4 Suction Upper 4 Supply Lower 5 Return Lower 6 Return Upper 7 Supply Upper 40RM 007 40RM 40RMQ 008 40RMS 008-012 40RM 012 40RMQ 012 40RM 014 40RMS 014-024 *See Fig. 4 for access hole location by number. †Fittings are listed in order from header or tee stub connection out to access hole in corner support post. 15 FITTINGS REQUIRED† (in.) 11⁄8 Street Elbow 11⁄8 Nipple, 105⁄8 L 11⁄8 Long Radius Elbow 5⁄8 Street Elbow 5⁄8 Nipple, 85⁄8 L 5⁄8 Long Radius Elbow 11⁄8 Street Elbow 11⁄8 Nipple, 85⁄8 L 11⁄8 Long Radius Elbow 5⁄8 Street Elbow 5⁄8 Nipple, 85⁄8 L 5⁄8 Long Radius Elbow 13⁄8 Nipple, 43⁄8 L 13⁄8 Long Radius Elbow 13⁄8 Nipple, 73⁄8 L 13⁄8 Long Radius Elbow 13⁄8 Nipple, 65⁄8 L 13⁄8 Long Radius Elbow (2) 11⁄8 Street Elbow 5⁄8 Street Elbow 5⁄8 Nipple, 81⁄2 L 5⁄8 Long Radius Elbow 5⁄8 Street Elbow 5⁄8 Nipple, 131⁄2 L 5⁄8 Long Radius Elbow 11⁄8 Nipple, 53⁄4 L 11⁄8 Long Radius Elbow 11⁄8 Nipple, 12 L 11⁄8 Long Radius Elbow (2) 11⁄8 Street Elbow 5⁄8 Street Elbow 5⁄8 Nipple, 51⁄2 L 5⁄8 Long Radius Elbow 5⁄8 Street Elbow 5⁄8 Nipple, 101⁄2 L 5⁄8 Long Radius Elbow 11⁄8 Nipple, 55⁄8 L 11⁄8 Long Radius Elbow 11⁄8 Nipple, 12 L 11⁄8 Long Radius Elbow 11⁄8 Street Elbow 11⁄8 Nipple, 75⁄8 L 11⁄8 Long Radius Elbow 5⁄8 Street Elbow 5⁄8 Nipple, 17⁄16 L 5⁄8 Long Radius Elbow 5⁄8 Street Elbow 5⁄8 Nipple, 111⁄2 L 5⁄8 Long Radius Elbow 11⁄8 Nipple, 55⁄8 L 11⁄8 Long Radius Elbow 11⁄8 Nipple, 13 L 11⁄8 Long Radius Elbow 13⁄8 Long Radius Elbow 13⁄8 Nipple, 33⁄4 L 13⁄8 Long Radius Elbow 13⁄8 Long Radius Elbow 13⁄8 Nipple, 33⁄8 L 13⁄8 Long Radius Elbow 13⁄8 Long Radius Elbow 13⁄8 Nipple, 7 L 13⁄8 Long Radius Elbow 13⁄8 Long Radius Elbow 13⁄8 Nipple, 113⁄4 L 13⁄8 Long Radius Elbow Table 3 — Fitting Requirements (cont) UNIT 40RM 016 40RMQ 016 40RM 024 40RM 028 ACCESS HOLE NO.* CONNECTION TYPE CIRCUIT 1 Suction Lower 2 Liquid Lower 3 Liquid Upper 4 Suction Upper 3 Suction Lower 5 Liquid Lower 6 Liquid Upper 7 Suction Upper 1 Suction Lower 2 Liquid Lower 3 Liquid Upper 4 Suction Upper 1 Suction Lower 2 Liquid Lower 3 Liquid Upper 4 Suction Upper *See Fig. 4 for access hole location by number. †Fittings are listed in order from header or tee stub connection out to access hole in corner support post. 16 FITTINGS REQUIRED† (in.) 11⁄8 Street Elbow 11⁄8 Nipple, 23⁄4 L 11⁄8 Long Radius Elbow 5⁄8 Street Elbow 5⁄8 Nipple, 13⁄8 L 5⁄8 Long Radius Elbow 5⁄8 Street Elbow 5⁄8 Nipple, 111⁄2 L 5⁄8 Long Radius Elbow 11⁄8 Nipple, 55⁄8 L 11⁄8 Long Radius Elbow 11⁄8 Nipple, 13 L 11⁄8 Long Radius Elbow 11⁄8 Nipple, 3 L 11⁄8 Long Radius Elbow 5⁄8 Nipple, 27⁄8 L 5⁄8 45° Elbow 5⁄8 Nipple, 15⁄8 L 5⁄8 Long Radius Elbow 5⁄8 Nipple, 27⁄8 L 5⁄8 45° Elbow 5⁄8 Nipple, 41⁄4 L 5⁄8 Long Radius Elbow 11⁄8 Nipple, 5 L 11⁄8 45° Elbow 11⁄8 Nipple, 83⁄4 L 11⁄8 Long Radius Elbow 11⁄8 Street Elbow 11⁄8 Nipple, 75⁄8 L 11⁄8 Long Radius Elbow 5⁄8 Street Elbow 5⁄8 Nipple, 61⁄2 L 5⁄8 Long Radius Elbow 5⁄8 Street Elbow 5⁄8 Nipple, 91⁄2 L 5⁄8 Long Radius Elbow 11⁄8 Nipple, 55⁄8 L 11⁄8 Long Radius Elbow 11⁄8 Nipple, 11 L 11⁄8 Long Radius Elbow 13⁄8 Street Elbow 13⁄8 Nipple, 11 L 13⁄8 Long Radius Elbow 5⁄8 Street Elbow 5⁄8 Nipple, 11⁄2 L 5⁄8 Long Radius Elbow 5⁄8 Street Elbow 5⁄8 Nipple, 193⁄4 L 5⁄8 Long Radius Elbow 13⁄8 Nipple, 43⁄16 L 13⁄8 Long Radius Elbow 13⁄8 Nipple, 231⁄4 L 13⁄8 Long Radius Elbow Table 3 — Fitting Requirements (cont) UNIT ACCESS HOLE NO.* CONNECTION TYPE CIRCUIT 5 Supply Lower 6 Return Lower 7 Return Upper 8 Supply Upper 1 Suction Lower 2 Liquid Lower 3 Liquid Upper 4 Suction Upper 40RMS 028, 034 40RM 034 FITTINGS REQUIRED† (in.) 21⁄8 Long Radius Elbow 21⁄8 Nipple, 31⁄2 L 21⁄8 Long Radius Elbow 21⁄8 Long Radius Elbow 21⁄8 Nipple, 3 L 21⁄8 Long Radius Elbow 21⁄8 Long Radius Elbow 21⁄8 Nipple, 67⁄8 L 21⁄8 Long Radius Elbow 21⁄8 Long Radius Elbow 21⁄8 Nipple, 117⁄8 L 21⁄8 Long Radius Elbow 13⁄8 Street Elbow 13⁄8 Nipple, 3 L 13⁄8 Long Radius Elbow 5⁄8 Street Elbow 5⁄8 Nipple, 73⁄4 L 5⁄8 Long Radius Elbow 5⁄8 Street Elbow 5⁄8 Nipple, 181⁄2 L 5⁄8 Long Radius Elbow 13⁄8 Nipple, 43⁄16 L 13⁄8 Long Radius Elbow 13⁄8 Nipple, 191⁄4 L 13⁄8 Long Radius Elbow *See Fig. 4 for access hole location by number. †Fittings are listed in order from header or tee stub connection out to access hole in corner support post. To size, design, and install chilled water piping, consult the Carrier System Design manual. See Fig. 9 for an example of a typical installation. Recommended fittings are listed in Table 3. To access 40RMS coil vents and drains, remove the unit side panel over the coil header. Vent and drain plugs are on the top and bottom of header, respectively. See the Service section for information on preventing coil freeze-up during winter. Chilled Water Piping — See Tables 1C and 1F for chilled water connection sizes. For ease in brazing, it is recommended that all internal solder joints be made before unit is placed in final position. Knockouts are provided in the unit corner posts for 40RM and 40RMQ refrigerant piping; additional field-fabricated access holes are required for 40RMS chilled water piping. See Fig. 4, which lists recommended knockouts and access holes to use for each 40RMS unit size. Fig. 9 — Typical 40RMS Chilled Water Piping 17 outlet at both ends of the unit, push drain pan down in the slots near the drain connection, and up in the slots on the opposite end. Retighten screws. The pan should have a pitch of at least 1⁄4-in. over its length toward the drain connection. Condensate Drain — Install a trapped condensate drain line to unit connection as shown in Fig. 10. The unit drain connection is a PVC stub. See Fig. 11. Some areas may require an adapter to connect to either galvanized steel or copper pipe. For these applications, install a field-supplied threaded PVC adapter. NOTE: A trap must be installed in the condensate drain line to ensure that the static pressure of fans is balanced with the water column in the drain line and that condensate can drain completely from pan. Without a trap, air can be drawn up drain line until water level in condensate pan becomes equal to static pressure created by fans, preventing complete drainage. Conditions will worsen as filters become dirty. Install clean-out plugs in trap. Pitch drain line downward to an open floor drain or sump. Provide service clearance around drain line to permit removal of unit panels. Observe all local sanitary codes. As shipped, the unit’s condensate drain pan is NOT sloped towards the drain connection. The pan slope must be changed to pitch towards the side of the unit with the drain connection. See Fig. 11. Loosen the 2 screws next to the drain Fan Motors and Drives — Motor and drive packages are factory installed in all units. The standard motor and drive packages consist of the following items: 1 — fan motor 1 — adjustable motor pulley 1 — fan pulley 1 —fan belt (40RM007-016, 40RMQ008-016, 40RMS 008-016 units) 2 —matched fan belts (40RM024-034, 40RMS024-034 units) For instructions on changing fan rotation, changing drive speeds and adjusting drives, see Pulley and Drive Adjustment in the Service section. Fig. 11 — Drain Pan Slope Adjustment NOTE: Dimensions in [ ] are in millimeters. Fig. 10 — Condensate Drains 18 230-v, 3-ph, 60 Hz operation. Rewire the motor according to the diagram plate on the motor. After reconfiguring the motor, place the sticker specifying 230-v operation (supplied in installation packet) over the 460-v sticker on the units corner post. Fan motors are factory installed on all units. Indoor-fan contactors are located in the fan contactor box behind the side access panel (see Fig. 12 and 13). Wire the thermostat to the 24-v control circuit terminal block located in the side of the fan contactor control box, according to Fig. 14 or the unit label diagram. If the air handler is part of a split system, complete the wiring from the condensing unit to the thermostat shown in Fig. 14. Power Supply and Wiring — Check the unit data plate to ensure that available power supply matches electrical characteristics of the unit. Provide a disconnect switch of size required to provide adequate fan motor starting current. See Tables 4 - 6 for unit electrical data. Install disconnect switch and power wiring in accordance with all applicable local codes. See Fig. 12-14 and the unit label diagram. For units with motor sizes less than 5 Hp (3.7 kW), connect power wiring to unit with no. 10 ring terminal. For units with motor sizes of 5 Hp (3.7 kW) or more, connect power wiring with 1⁄4-in. ring terminal. The 40RM, 40RMQ and 40RMS size 007-016 units (except 40RM016 with YC or WD option) that have motors wired for 460-v, 3-ph, 60 Hz operation can be field-converted to 105° C 600V RJ AW FAN DRIVE PULLEY 13 TXV BULB ACCESS FAN CONTACTOR FILTER RETAINER CLIP 12 FILTER ELEMENTS 11 COIL 23 CONDENSATE DRAIN CONNECTION (HORIZONTAL) WIRING ACCESS 22 MOTOR AND DRIVE FAN CONTACTOR BOX 21 FAN SCROLL REFRIGERANT/ CHILLED WATER PIPING ACCESS 24V TERMINAL BLOCK CONDENSATE DRAIN CONNECTION (VERTICAL) POWER WIRING KNOCKOUT TXV — Thermostatic Expansion Valve Fig. 13 — Fan Contactor Box and Terminal Block (Cover Removed) (Typical) Fig. 12 — Wiring and Service Access (Side Panel Removed) 19 Table 4 — Electrical Data, Standard Motors UNIT 40RM 007 40RM 40RMQ 40RMS 008 40RMS 010 40RM 40RMQ 40RMS 012 40RM 40RMS 014 40RM 40RMQ 40RMS 016 40RM 40RMS 024 40RM 40RMS 028 40RM 40RMS 034 FAN MOTOR V*-PH-HZ VOLTAGE LIMITS Hp FLA 208/230-1-60 208/230-3-60 460-3-60 575-3-60 230-3-50 400-3-50 208/230-1-60 208/230-3-60 460-3-60 575-3-60 230-3-50 400-3-50 208/230-1-60 208/230-3-60 460-3-60 575-3-60 230-3-50 400-3-50 208/230-3-60 460-3-60 575-3-60 230-3-50 400-3-50 208/230-3-60 460-3-60 575-3-60 230-3-50 400-3-50 208/230-3-60 460-3-60 575-3-60 230-3-50 400-3-50 208/230-3-60 460-3-60 575-3-60 230-3-50 400-3-50 208/230-3-60 460-3-60 575-3-60 230-3-50 400-3-50 208/230-3-60 460-3-60 575-3-60 230-3-50 440-3-50 187-253 187-253 414-528 518-632 207-253 360-440 187-253 187-253 414-528 518-632 207-253 360-440 187-253 187-253 414-528 518-632 207-253 360-440 187-253 414-528 518-632 207-253 360-440 187-253 414-528 518-632 207-253 360-440 187-253 414-528 518-632 207-253 360-440 187-253 414-528 518-632 207-253 360-440 187-253 414-528 518-632 207-253 360-440 187-253 414-528 518-632 207-253 360-440 1.3 2.4 2.4 1.0 2.4 2.4 2.4 2.4 2.4 2.0 2.4 2.4 2.4 2.4 2.4 2.0 2.4 2.4 2.4 2.4 2.0 2.9 2.9 2.9 2.9 3.0 2.9 2.9 3.7 3.7 3.0 2.9 2.9 5.0 5.0 5.0 5.0 5.0 7.5 7.5 7.5 7.5 7.5 10.0 10.0 10.0 10.0 10.0 7.6 5.8 2.6 1.35 5.8 2.6 11.0 5.8 2.6 2.4 5.8 2.6 11.0 5.8 2.6 2.4 5.8 2.6 5.8 2.6 2.4 7.5 3.4 7.5 3.4 3.8 7.5 3.4 10.6 4.8 3.8 7.5 3.4 15.2/14.4 7.2 5.6 14.4 7.2 22.0/21.0 10.5 7.6 21.0 10.5 26.4/25.0 12.5 9.6 25.0 12.5 See Legend and Notes on page 21. 20 POWER SUPPLY Minimum MOCP Circuit Amps 9.5 15 7.3 15 3.3 15 1.7 15 7.3 15 3.3 15 13.8 20 7.3 15 3.3 15 3.0 15 7.3 15 3.3 15 13.8 20 7.3 15 3.3 15 3.0 15 7.3 15 3.3 15 7.3 15 3.3 15 3.0 15 9.4 15 4.3 15 9.4 15 4.3 15 4.8 15 9.4 15 4.3 15 13.3 20 6.0 15 4.8 15 9.4 15 4.3 15 19.0/18.0 30/30 9.0 15 7.0 15 18.0 30 9.0 15 27.5/26.3 45/45 13.1 20 9.5 15 26.3 45 13.1 20 33.0/31.3 55/55 15.6 25 12.0 20 31.3 55 15.6 25 Table 5 — Electrical Data, Alternate Motors 40RM 007 40RM 40RMQ 40RMS 008 40RMS 010 40RM 40RMQ 40RMS 012 40RM 40RMS 014 40RM 40RMQ 40RMS 016 40RM 40RMS 024 40RM 40RMS 028 FAN MOTOR V*-PH-HZ VOLTAGE LIMITS Hp FLA 208/230-1-60 208/230-3-60 460-3-60 575-3-60 208/230-3-60 460-3-60 575-3-60 230-3-50 400-3-50 208/230-3-60 460-3-60 575-3-60 230-3-50 400-3-50 208/230-3-60 460-3-60 575-3-60 230-3-50 400-3-50 208/230-3-60 460-3-60 575-3-60 230-3-50 400-3-50 208/230-3-60 460-3-60 575-3-60 230-3-50 400-3-50 208/230-3-60 460-3-60 575-3-60 230-3-50 400-3-50 208/230-3-60 460-3-60 575-3-60 230-3-50 400-3-50 187-253 187-253 414-528 518-632 187-253 414-528 518-632 207-253 360-440 187-253 414-528 518-632 207-253 360-440 187-253 414-528 518-632 207-253 360-440 187-253 414-528 518-632 207-253 360-440 187-253 414-528 518-632 207-253 360-440 187-253 414-528 518-632 207-253 360-440 187-253 414-528 518-632 207-253 360-440 2.4 2.9 2.9 2.0 2.9 2.9 3.0 2.9 2.9 2.9 2.9 3.0 2.9 2.9 3.7 3.7 3.0 5.0 5.0 3.7 3.7 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 7.5 7.5 7.5 7.5 7.5 10.0 10.0 10.0 10.0 10.0 11.0 7.5 3.4 2.4 7.5 3.4 3.8 7.5 3.4 7.5 3.4 3.8 7.5 3.4 10.6 4.8 3.8 14.4 7.2 10.6 4.8 5.6 14.4 7.2 15.2/14.4 7.2 5.6 14.4 7.2 22.0/21.0 10.5 7.6 21.0 10.5 26.4/25.0 12.5 9.6 25.0 12.5 UNIT LEGEND EXAMPLE: Supply voltage is 400-3-50. AB = 393 v BC = 403 v AC = 396 v 393 + 403 + 396 Average Voltage = 3 1192 = 3 = 397 Determine maximum deviation from average voltage. (AB) 397 − 393 = 4 v (BC) 403 − 397 = 6 v (AC) 397 − 396 = 1 v Maximum deviation is 6 v. FLA — Full Load Amps MOCP — Maximum Overcurrent Protection *Motors are designed for satisfactory operation within 10% of nominal voltages shown. Voltages should not exceed the limits shown in the Voltage Limits column. NOTES: 1. Minimum Circuit Amp and MOCP values are calculated in accordance with NEC (National Electrical Code) (U.S.A. standard), Article 440. 2. Motor FLA values are established in accordance with UL (Underwriters’ Laboratories) Standard 1995 (U.S.A. standard). 3. Unbalanced 3-Phase Supply Voltage Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use the following formula to determine the percentage of voltage imbalance. Determine percent voltage imbalance. 6 % Voltage Imbalance = 100 x 397 = 1.5% This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%. % Voltage Imbalance = 100 x POWER SUPPLY Minimum MOCP Circuit Amps 13.8 20 9.4 15 4.3 15 3.0 15 9.4 15 4.3 15 4.8 15 9.4 15 4.3 15 9.4 15 4.3 15 4.8 15 9.4 15 4.3 15 13.3 20 6.0 15 4.8 15 18.0 30 9.0 15 13.3 20 6.0 15 7.0 15 18.0 30 9.0 15 19.9/18.0 30/30 9.0 15 7.0 15 18.0 30 9.0 15 27.5/26.3 45/45 13.1 20 9.5 15 26.3 45 13.1 20 33.0/31.3 55/55 15.6 25 12.0 20 31.3 55 15.6 25 max voltage deviation from average voltage average voltage IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your local electric utility company immediately. 21 LEGEND — Circuit Breaker — Heating Contactor — Electric Heater — Indoor-Fan Contactor — Indoor-Fan Motor — National Electrical Code — Terminal Block — Thermostat Factory Wiring Field Control Wiring NOTE: Use copper conductors only. CB HC HTR IFC IFM NEC TB T’STAT → Fig. 14 — Unit Wiring Table 6 — Fan Contactor Coil Data UNIT 40RM, 40RMQ 40RMS 007-034 VOLTAGE (vac) 24 MAXIMUM HOLDING VA 10 Connecting Ductwork — Refer to the Carrier System Design Manual for the recommended design and layout of ductwork. Figure 15 shows recommended duct connection to units with 2 fans. DISCHARGE CONNECTIONS — Duct flanges are factory supplied; they are shipped inside the unit attached to the hairpin end of the coil tube sheet for field installation. Using the existing screws, install the duct flanges on the unit’s fan deck. Each fan discharge requires 2 flanges; each flange must be bent in the middle to conform to the discharge opening. See Fig. 16. After flanges are installed, connect them to the supply duct using a canvas connection to prevent vibration. It is important that this connection be properly fabricated to prevent high air friction losses and air noise. RETURN CONNECTION — When using return-air ductwork, route return-air duct to the unit’s return air inlet near the filter rack, using a canvas connection to prevent transmission of unit vibration. If the duct blocks off the unit’s access panel, provide a slip joint in the ductwork to permit removal for servicing. OUTDOOR-AIR INLET CONNECTION — Connect outdoorair inlet to field-installed accessory economizer. Refer to economizer Installation Instructions. Return-Air Filters — Type and size of filters are shown in Tables 1A-1F and are factory-supplied and installed. In all units with 2 fans, a filter replacement tool (hook) is shipped inside the unit for field use when replacing filters. See the Service section for instructions on filter element replacement. 596 Fig. 15 — Typical Fan Discharge Connections for Multiple Fan Units 22 Fig. 16 — Duct Flange Installation START-UP Fan Motor Lubrication — Fan motor supplied with unit is permanently lubricated and requires no further lubrication. Before starting unit, check the following and correct as necessary: • Is unit solidly supported? • Is fan adjusted for speed and pulley alignment? • Are pulleys, motor, and bearings securely mounted? • Are there any loose parts that will rattle or vibrate? • Is condensate drain pan pitched for correct drainage? • Are coil baffle plates tight against coil to prevent air bypass? • Are all panels securely fastened? • Are all electrical connections correct and tight? Fan Shaft Bearings — Bearings on 007-012 size units are sealed, permanently lubricated bearings that require no further lubrication. Size 014-034 units have pillow-block bearings (Fig. 17) that must be lubricated with suitable bearing grease approximately every 3 months. See Table 7 for suitable lubricants. Table 7 — Lubricant Data MANUFACTURER Sunoco Texaco Texaco Mobil Also refer to condensing unit instructions before starting a split system. A split system start-up checklist is provided in the back of these instructions. LUBRICANT Prestige 42 Multifak 2 Regal AFB-2* Mobilplex EP No. 2 *Preferred lubricant because it contains rust and oxidation inhibitors. SERVICE Inspection and maintenance should be performed at regular intervals and should include the following: • Complete cleaning of cabinet, fan wheel, cooling coil, condensate pan and drain, heating coils, and return-air grille (if present). • Inspection of panels and sealing of unit against air leakage. • Adjustment of fan motor, belt, bearings, and wheels. • Cleaning or replacement of filters. • Testing for cooling/heating system leaks. • Checking of all electrical connections. Most unit service can be performed by removing one or both of the unit’s side panels. Coil cleaning or removal or insulation cleaning may require removal of a rear, top, or bottom panel, depending on the unit’s orientation. When service is completed, replace unit panels. Panels — Panels are fastened to unit frame with sheet metal screws. Fan and coil compartment must be sealed tightly after service to prevent air from bypassing the cooling coil. Fig. 17 — Fan Shaft, Bearings, and Fan Wheel (Typical) 23 Centering Fan Wheel — If fan and fan shaft assem- Individual Fan Wheel Adjustment — Loosen the bly are not properly centered, blades may scrape against scroll or may create an objectionable whistling noise. It may be necessary to adjust individual fan wheels or move entire fan shaft. See the following two sections. 2 locking bolts holding fan wheel hub to shaft. See Fig. 17. Position fan wheel in center of the fan housing and tighten locking bolts. Clearance between wheel and housing should be the same on both sides. Fan Shaft Position Adjustment — Loosen setscrew or locking collar of each fan shaft bearing. Slide shaft into correct position and replace locking collar (Fig. 18). To replace locking collar, push collar up against inner face of bearing. Turn collar in direction of fan rotation until tight, and tighten setscrew. Tightening locking collar in direction of fan rotation results in further tightening of collar should setscrew work itself loose. Fan Belts — Motor mounting plate and motor support angles are slotted to permit both vertical and horizontal adjustment. Adjust belt(s) for correct deflection by loosening motor plate mounting bolts, moving motor/plate assembly forward or back, and retightening bolts. Press down on belt with one finger midway between fan and motor pulleys to check deflection. For units with motor sizes up to and including 3.7 Hp (2.76 kW), correct deflection is 3⁄16-in. (4.8 mm) For larger motor sizes, correct deflection is 1⁄8-in. (3.2 mm). See Fig. 19. NOTE: The 028 and 034 size units with 60 Hz motors are shipped with an extra set of matching belts. Use the preinstalled belts or extra belts depending on the adjustable pulley setting. If complete belt replacement is required during servicing, loosen the motor plate mounting bolts (Fig. 19), move motor/plate assembly towards fan pulley, and pull belt(s) off pulleys. Reverse the procedure with new bolts and readjust deflection. Fan Rotation — Correct fan rotation with respect to fan outlet is shown in Fig. 20. To reverse the direction of rotation of a 3-phase fan motor, reverse any 2 of the power leads. Refer to the connection diagram on the inside of motor terminal box cover for proper reversing procedure of single-phase motor. Fig. 18 — Fan Shaft Bearing Fig. 19 — Fan Motor Mounting 24 Fig. 20 — Fan Rotation Fan Pulley Alignment — Align as follows: 1. Loosen setscrews on pulleys. 2. Align pulleys visually and tighten setscrews on fan pulley to lock it in place. 3. Use the methods shown in Fig. 21 to check proper pulley alignment. 4. If pulleys are not in correct alignment, loosen the motor holddown bolts and slide the motor axially until the pulleys are aligned. 5. Tighten motor holddown bolts. Fig. 21 — Fan Pulley Adjustments Alternative freeze protection methods follow: • Circulate hot water within the water coil’s supply main or supplementary space heating. • Close off supply lines to unit and open a union or fieldsupplied drain valve in the return line. Pulley and Drive Adjustment — To obtain desired fan speed, refer to the fan motor and drive data in Tables 8A-10D and adjust fan motor pulley as follows: IMPORTANT: Draining from return line will not completely drain water from coils. 1. Remove belt from fan motor pulley after loosening motor from motor base. 2. Loosen setscrew in moveable flange of pulley. Screw moveable flange toward fixed flange to increase the fan speed and away from fixed flange to reduce speed. Before tightening setscrew, make certain that setscrew is over nearest flat surface of pulley hub (Fig. 21). After draining as much water as possible from coils, add sufficient antifreeze to prevent residual water in the coil from freezing. • Add a sufficient quantity of non-corrosive antifreeze to the entire system to prevent all water within the system from freezing. Coil Removal — Remove unit panels and corner posts as required. Disconnect coil connections and remove fastening screws. Remove coil through end or side sections of unit. Increasing fan speed produces a greater load on motor. Do not exceed rated capacity of motor. Cleaning Cooling Coil — Remove return-air filters. Remove any heavy dirt that may have accumulated on underside of coil. Coil can be cleaned more easily with a stiff brush, vacuum cleaner, or compressed air when coil is dry. If coil is wet or if water is to be used for cleaning, guard against splashing water on electrical components or damaging surrounding area. Clean coil baffles as applicable and check for tight fit to be sure air does not bypass coil. Condensate Drains — Keep condensate drains free of dirt and foreign matter. Return-Air Filters — Refer to Replacing Filters section, page 39, for filter accessibility and removal. Replace with clean filters of the sizes listed in Tables 1A-1F. Cleaning Insulation — The insulation contains an Chilled Water Coil Freeze Protection — Shut off water supply to unit. Remove side panel of unit and remove vent and drain plugs in top and bottom of coil header. Drain coil and blow out remaining water. Reinstall plugs and side panel. immobilized antimicrobial agent that helps prevent the growth of bacteria and fungi. Clean the inner surface of the insulation according to the separate maintenance instructions shipped with the unit. 25 Table 8A — Fan Motor Data, Standard Motor — English UNIT 40RM 007 208/230-1-60 Speed (rpm) 1725 Hp 1.3 Frame (NEMA) 56Y 5⁄8 Shaft Dia (in.) 208/230-3-60 and 460-3-60 Speed (rpm) 1725 Hp 2.4 Frame (NEMA) 56Y 5⁄8 Shaft Dia (in.) 575-3-60 Speed (rpm) 1725 Hp 1.0 Frame (NEMA) 56 5⁄8 Shaft Dia (in.) 230-3-50 and 400-3-50 Speed (rpm) 1425 Hp 2.4 Frame (NEMA) 56Y 5⁄8 Shaft Dia (in.) 40RM 40RMQ 40RMS 008 40RMS 010 40RM 40RMQ 40RMS 012 40RM 40RMS 014 40RM 40RMQ 40RMS 016 40RM 40RMS 024 40RM 40RMS 028 40RM 40RMS 034 1725 2.4 56Y 5 ⁄8 1725 2.4 56Y 5⁄8 — — — — — — — — — — — — — — — — — — — — — — — — 1725 2.4 56Y 5 ⁄8 1725 2.4 56Y 5⁄8 1725 2.4 56Y 5 ⁄8 1725 2.9 56Y 7 ⁄8 1725 3.7 56Y 7 ⁄8 1745 5.0 S184T 1 1 ⁄8 1745 7.5 S213T 13⁄8 1745 10.0 S215T 13⁄8 1725 2.0 56HZ 7 ⁄8 1725 2.0 56HZ 7⁄8 1725 2.0 56HZ 7 ⁄8 1725 3.0 56HZ 7 ⁄8 1725 3.0 56HZ 7 ⁄8 1745 5.0 184T 1 1 ⁄8 1755 7.5 S213T 13⁄8 1755 10.0 D215T 13⁄8 1425 2.4 56Y 5 ⁄8 1425 2.4 56Y 5⁄8 1425 2.9 56Y 7 ⁄8 1425 2.9 56Y 7 ⁄8 1425 2.9 56Y 7 ⁄8 1425 5.0 184T 1 1 ⁄8 1425 7.5 S213T 13⁄8 1425 10.0 S215T 13⁄8 NEMA — National Electrical Manufacturers Association Table 8B — Fan Motor Data, Alternate Motor — English UNIT 40RM 007 208/230-1-60 Speed (rpm) 1725 Hp 2.4 Frame (NEMA) 56Y 5⁄8 Shaft Dia (in.) 208/230-3-60 and 460-3-60 Speed (rpm) 1725 Hp 2.9 Frame (NEMA) 56Y 7⁄8 Shaft Dia (in.) 575-3-60 Speed (rpm) 1725 Hp 2.0 Frame (NEMA) 56HZ 7⁄8 Shaft Dia (in.) 230-3-50 and 400-3-50 Speed (rpm) — Hp — Frame (NEMA) — Shaft Dia (in.) — 40RM 40RMQ 40RMS 008 40RMS 010 40RM 40RMQ 40RMS 012 40RM 40RMS 014 40RM 40RMQ 40RMS 016 40RM 40RMS 024 40RM 40RMS 028 — — — — — — — — — — — — — — — — — — — — — — — — — — — — 1725 2.9 56Y 7 ⁄8 1725 2.9 56Y 7⁄8 1725 3.7 Y56Y 7 ⁄8 1725 3.7 Y56Y 7⁄8 1725 5.0 S184T 11⁄8 1745 7.5 S213T 13⁄8 1745 10.0 S215T 13⁄8 1725 3.0 56HZ 7 ⁄8 1725 3.0 56HZ 7⁄8 1725 3.0 56HZ 7 ⁄8 1745 5.0 184T 1 1 ⁄8 1745 5.0 184T 11⁄8 1755 7.5 S213T 13⁄8 1750 10.0 D215T 13⁄8 1425 2.9 56Y 7 ⁄8 1425 2.9 56Y 7⁄8 1425 5.0 S184T 7 ⁄8 1425 5.0 S184T 1 1 ⁄8 1425 5.0 S184T 11⁄8 1425 7.5 S213T 13⁄8 1425 10.0 S215T 13⁄8 NEMA — National Electrical Manufacturers Association 26 Table 8C — Fan Motor Data, Standard Motor — SI UNIT 40RM 007 208/230-1-60 Speed (r/s) 28.75 Shaft kW 0.97 Frame (NEMA) 56Y Shaft Dia (mm) 15.9 208/230-3-60 and 460-3-60 Speed (r/s) 28.75 Shaft kW 1.79 Frame (NEMA) 56Y Shaft Dia (mm) 15.9 575-3-60 Speed (r/s) 28.75 Shaft kW 0.746 Frame (NEMA) 56 Shaft Dia (mm) 15.9 230-3-50 and 400-3-50 Speed (r/s) 23.75 Shaft kW 1.79 Frame (NEMA) 56Y Shaft Dia (mm) 15.9 40RM 40RMQ 40RMS 008 40RMS 010 40RM 40RMQ 40RMS 012 40RM 40RMS 014 40RM 40RMQ 40RMS 016 40RM 40RMS 024 40RM 40RMS 028 40RM 40RMS 034 28.75 1.79 56Y 15.9 28.75 1.79 56Y 15.9 — — — — — — — — — — — — — — — — — — — — — — — — 28.75 1.79 56Y 15.9 28.75 1.79 56Y 15.9 28.75 1.79 56Y 15.9 28.75 2.16 56Y 22.2 28.75 2.76 56Y 22.2 29.08 3.73 S184T 28.6 29.08 5.60 S213T 34.9 29.08 7.46 S215T 34.9 28.75 1.49 56HZ 22.2 28.75 1.49 56HZ 22.2 28.75 1.49 56HZ 22.2 28.75 2.24 56HZ 22.2 28.75 2.24 56HZ 22.2 29.08 3.73 184T 28.6 29.25 5.60 S213T 34.9 29.25 7.46 S215T 34.9 23.75 1.79 56Y 15.9 23.75 1.79 56Y 15.9 23.75 2.16 56Y 22.2 23.75 2.16 56Y 22.2 23.75 2.16 56Y 22.2 23.75 3.73 184T 28.6 23.75 5.60 S213T 34.9 23.75 7.46 S215T 34.9 NEMA — National Electrical Manufacturers Association Table 8D — Fan Motor Data, Alternate Motor — SI UNIT 40RM 007 208/230-1-60 Speed (r/s) 28.75 Shaft kW 1.79 Frame (NEMA) 56Y Shaft Dia (mm) 15.9 208/230-3-60 and 460-3-60 Speed (r/s) 28.75 Shaft kW 2.16 Frame (NEMA) 56Y Shaft Dia (mm) 22.2 575-3-60 Speed (r/s) 28.75 Shaft kW 1.49 Frame (NEMA) 56HZ Shaft Dia (mm) 22.2 230-3-50 and 400-3-50 Speed (r/s) — Shaft kW — Frame (NEMA) — Shaft Dia (mm) — 40RM 40RMQ 40RMS 008 40RMS 010 40RM 40RMQ 40RMS 012 40RM 40RMS 014 40RM 40RMQ 40RMS 016 40RM 40RMS 024 40RM 40RMS 028 — — — — — — — — — — — — — — — — — — — — — — — — — — — — 28.75 2.16 56Y 22.2 28.75 2.16 56Y 22.2 28.75 2.76 Y56Y 22.2 28.75 2.76 Y56Y 22.2 29.08 3.73 S184T 28.6 29.08 5.60 S213T 34.9 29.17 7.46 S215T 34.9 28.75 2.24 56HZ 22.2 28.75 2.24 56HZ 22.2 28.75 2.24 56HZ 22.2 29.08 3.73 184T 28.6 29.08 3.73 184T 28.6 29.25 5.60 S213T 34.9 29.17 7.46 D215T 34.9 23.75 2.16 56Y 22.2 23.75 2.16 56Y 22.2 23.75 3.73 S184T 22.2 23.75 3.73 S184T 28.6 23.75 3.73 S184T 28.6 23.75 5.60 S213T 34.9 23.75 7.46 S215T 34.9 NEMA — National Electrical Manufacturers Association 27 Table 9A — Standard Drive Data, 60 Hz — English UNIT MOTOR DRIVE Motor Pulley Pitch Diameter (in.) Pulley Factory Setting Full Turns Open FAN DRIVE Pulley Pitch Dia (in.) Pulley Bore (in.) Belt No. — Section Belt Pitch (in.) FAN SPEEDS (rpm) Factory Setting Range Max Allowable Speed (rpm) Change per 1⁄2 Turn of Moveable Motor Pulley Flange MAX FULL TURNS FROM CLOSED POSITION SHAFTS CENTER DISTANCE (in.) 40RM 007 40RM 40RMQ 40RMS 008 40RMS 010 40RM 40RMQ 40RMS 012 40RM 40RMS 014 40RM 40RMQ 40RMS 016 40RM 40RMS 024 40RM 40RMS 028 40RM 40RMS 034 2.4-3.4 2.8-3.8 2.8-3.8 3.4-4.4 2.8-3.8 2.8-3.8 3.7-4.7 4.3-5.3 4.3-5.3 2.5 2.5 2.5 2.5 2.5 2.5 3.0 3.0 3.0 8.8 1 1—A 8.8 1 1—A 8.8 1 1—A 8.8 1 1—A 9.0 17⁄16 1—A 9.0 17⁄16 1—A 9.4 17⁄16 2—B 40.3 41.3 41.3 42.3 42.3 42.3 41.8 11.0 115⁄16 2—B* (2) 42.8 (2) 43.8 11.0 115⁄16 2—B* (2) 42.8 (2) 43.8 568 470-666 1200 647 549-745 1200 647 549-745 1200 764 666-863 1200 632 537-728 1200 632 537-728 1200 771 679-863 1200 752 682-841 1100 752 674-831 1100 19.6 19.6 19.6 19.7 19.1 19.1 15.3 13.1 13.1 5 5 5 5 5 5 6 6 6 10.4412.32 10.4412.32 10.4412.32 10.4412.32 10.4412.32 10.4412.32 9.1210.99 6.679.43 6.679.43 *Four belts shipped with unit. Use correct set of 2 belts sized according to the pulley setting. Table 9B — Medium-Static Drive Data, 60 Hz — English UNIT MOTOR DRIVE Motor Pulley Pitch Diameter (in.) Pulley Factory Setting Full Turns Open FAN DRIVE Pulley Pitch Dia (in.) Pulley Bore (in.) Belt No. — Section Belt Pitch (in.) FAN SPEEDS (rpm) Factory Setting Range Max Allowable Speed (rpm) Change per 1⁄2 Turn of Moveable Motor Pulley Flange MAX FULL TURNS FROM CLOSED POSITION SHAFTS CENTER DISTANCE (in.) 40RM 007 40RM 40RMQ 40RMS 008 40RMS 010 40RM 40RMQ 40RMS 012 40RM 40RMS 014 40RM 40RMQ 40RMS 016 40RM 40RMS 024 40RM 40RMS 028 40RM 40RMS 034 3.4-4.4 3.4-4.4 3.4-4.4 3.4-4.4 3.4-4.4 3.7-4.7 4.3-5.3 4.3-5.3 4.3-5.3 2.5 2.5 2.5 2.5 2.5 3.0 3.0 3.0 3.0 8.8 1 1—A 8.0 1 1—A 8.0 1 1—A 8.0 1 1—A 8.2 17⁄16 1—A 8.6 17⁄16 1—B 9.4 17⁄16 2—B 42.3 40.3 40.3 40.3 41.3 41.8 41.8 9.4 115⁄16 2—B* (2) 38.8 (2) 39.8 9.4 115⁄16 2—B* (2) 38.8 (2) 39.8 764 666-863 1200 841 733-949 1200 841 733-949 1200 841 733-949 1200 820 715-926 1200 842 742-943 1200 881 798-984 1200 881 798-984 1100 881 798-984 1100 19.7 21.6 21.6 21.6 21.1 16.7 15.3 15.3 15.3 5 5 5 5 5 6 6 6 6 10.4412.32 10.4412.32 10.4412.32 10.4412.32 10.4412.32 10.4412.32 9.1610.99 6.679.43 6.679.43 *Four belts shipped with unit. Use correct set of 2 belts sized according to the pulley setting. 28 Table 9C — High-Static Drive Data, 60 Hz — English UNIT MOTOR DRIVE Motor Pulley Pitch Diameter (in.) Pulley Factory Setting Full Turns Open FAN DRIVE Pulley Pitch Dia (in.) Pulley Bore (in.) Belt No. — Section Belt Pitch (in.) FAN SPEEDS (rpm) Factory Setting Range Max Allowable Speed (rpm) Change per 1⁄2 Turn of Moveable Motor Pulley Flange MAX FULL TURNS FROM CLOSED POSITION SHAFTS CENTER DISTANCE (in.) 40RM 007 40RM 40RMQ 40RMS 008 40RMS 010 40RM 40RMQ 40RMS 012 40RM 40RMS 014 40RM 40RMQ 40RMS 016 40RM 40RMS 024 40RM 40RMS 028 40RM 40RMS 034 3.4-4.4 3.4-4.4 3.4-4.4 3.4-4.4 3.7-4.7 4.3-5.3 4.3-5.3 4.3-5.3 4.3-5.3 2.5 2.5 2.5 2.5 3.0 3.0 3.0 3.0 3.0 7.0 1 1—A 41.3 6.0* 1 1—A 37.3 6.0 1 1—A 37.3 6.0 1 1—A 37.3 7.4 17⁄16 1—B 39.8 7.9 17⁄16 1—B 39.8 7.4 17⁄16 2—B 36.8 8.6 115⁄16 2—B 37.8 8.6 115⁄16 2—B 37.8 961 8381084 1200 1121 9781200*† 1200 1121 9781200† 1200 1121 9781200† 1200 979 8731096 1200 1060 9501171 1200 1118 10141200† 1200 1024 8731075 — 1024 8731075 — 24.6 28.7 28.7 28.7 19.4 18.4 19.4 16.7 16.7 5 5 5 5 6 6 6 6 6 10.4412.32 10.4412.32 10.4412.32 10.4412.32 10.4412.32** 9.1610.99 8.1610.02 6.679.43 6.679.43 *Valves for 3-phase motor shown. For single-phase motor, pulley pitch diameter is 7 in. and resulting fan speed is 837-1096 rpm. †It is possible to adjust drive so that fan speed exceeds maximum allowable. DO NOT exceed 1200 rpm. **575-v unit has a center distance of 9.16-10.99. Table 9D — Standard Drive Data, 50 Hz — English UNIT MOTOR DRIVE Motor Pulley Pitch Diameter (in.) Pulley Factory Setting Full Turns Open FAN DRIVE Pulley Pitch Dia (in.) Pulley Bore (in.) Belt No. — Section Belt Pitch (in.) FAN SPEEDS (rpm) Factory Setting Range Max Allowable Speed (rpm) Change per 1⁄2 Turn of Moveable Motor Pulley Flange MAX FULL TURNS FROM CLOSED POSITION SHAFTS CENTER DISTANCE (in.) 40RM 007 40RM 40RMQ 40RMS 008 40RMS 010 40RM 40RMQ 40RMS 012 40RM 40RMS 014 40RM 40RMQ 40RMS 016 40RM 40RMS 024 40RM 40RMS 028 40RM 40RMS 034 2.4-3.4 2.8-3.8 2.8-3.8 3.4-4.4 3.4-4.4 3.4-4.4 4.3-5.3 4.3-5.3 4.3-5.3 2.5 2.5 2.5 2.5 2.5 2.5 3.0 3.0 3.0 8.0 1 1—A 39.3 8.0 1 1—A 39.3 8.0 1 1—A 39.3 8.0 1 1—A 40.3 9.0 17⁄16 1—A 42.3 9.0 17⁄16 1—A 42.3 8.6 17⁄16 1—B 41.8 11.0 115⁄16 2—B 43.8 11.0 115⁄16 2—B 43.8 517 428-606 1200 588 499-677 1200 588 449-677 1200 695 606-784 1200 618 538-697 1200 618 538-697 1200 795 713-878 1200 622 557-687 1100 622 557-687 1100 17.8 17.8 17.8 17.8 15.9 15.9 13.8 10.8 10.8 5 5 5 5 5 5 6 6 6 10.4412.32 10.4412.32 10.4412.32 10.4412.32 10.4412.32 10.4412.32 9.1210.99 6.679.43 6.679.43 29 Table 9E — Medium-Static Drive Data, 50 Hz — English UNIT MOTOR DRIVE Motor Pulley Pitch Diameter (in.) Pulley Factory Setting Full Turns Open FAN DRIVE Pulley Pitch Dia (in.) Pulley Bore (in.) Belt No. — Section Belt Pitch (in.) FAN SPEEDS (rpm) Factory Setting Range Max Allowable Speed (rpm) Change per 1⁄2 Turn of Moveable Motor Pulley Flange MAX FULL TURNS FROM CLOSED POSITION SHAFTS CENTER DISTANCE (in.) 40RM 007 40RM 40RMQ 40RMS 008 40RMS 010 40RM 40RMQ 40RMS 012 40RM 40RMS 014 40RM 40RMQ 40RMS 016 40RM 40RMS 024 40RM 40RMS 028 40RM 40RMS 034 3.4-4.4 3.4-4.4 3.4-4.4 3.4-4.4 3.4-4.4 3.7-4.7 4.0-5.0 4.3-5.3 4.3-5.3 2.5 2.5 2.5 2.5 2.5 3.0 2.5 3.0 3.0 8.0 1 1—A 40.3 7.0 1 1—A 41.3 7.0 1 1—A 41.3 6.0 1 1—A 37.3 7.5 17⁄16 1—A 39.3 7.9 17⁄16 1—B 39.8 7.0 17⁄16 2—A 36.8 9.4 115⁄16 2—B 39.8 9.4 115⁄16 2—B 39.8 695 606-784 1200 794 692-896 1200 794 692-896 1200 926 808-1045 1200 741 646-836 1200 756 667-848 1200 916 814-1018 1200 728 652-803 1100 728 652-803 1100 17.8 20.4 20.4 23.7 19.0 15.1 20.4 12.6 12.6 5 5 5 5 5 6 5 6 6 10.4412.32 10.4412.32 10.4412.32 10.4412.32 10.4412.32 9.1610.99 9.1610.99 6.679.43 6.679.43 Table 9F — High-Static Drive Data, 50 Hz — English UNIT MOTOR DRIVE Motor Pulley Pitch Diameter (in.) Pulley Factory Setting Full Turns Open FAN DRIVE Pulley Pitch Dia (in.) Pulley Bore (in.) Belt No. — Section Belt Pitch (in.) FAN SPEEDS (rpm) Factory Setting Range Max Allowable Speed (rpm) Change per 1⁄2 Turn of Moveable Motor Pulley Flange MAX FULL TURNS FROM CLOSED POSITION SHAFTS CENTER DISTANCE (in.) 40RM 007 40RM 40RMQ 40RMS 008 40RMS 010 40RM 40RMQ 40RMS 012 40RM 40RMS 014 40RM 40RMQ 40RMS 016 40RM 40RMS 024 40RM 40RMS 028 40RM 40RMS 034 3.4-4.4 3.4-4.4 3.4-4.4 4.0-5.0 3.4-4.4 4.0-5.0 4.0-5.0 4.3-5.3 4.3-5.3 2.5 2.5 2.5 3.0 2.5 3.0 3.0 3.0 3.0 6.0 1 1—A 37.3 5.5 1 1—A 37.3 5.5 1 1—A 37.3 5.5 1 1—A 36.3 6.0 17⁄16 2—A 36.3 7.0 17⁄16 2—A 39.3 6.4 17⁄16 2—A 34.3 8.0 115⁄16 2—B 36.8 8.6 115⁄16 2—B 37.8 926 8081045 1200 1010 8811140 1200 1010 8811140 1200 1166 10361200* 1200 926 8081045 1200 916 8141018 1200 1002 8911113 1200 855 766944 1100 795 713878 1100 23.7 25.9 25.9 21.6 23.7 17.0 18.5 14.8 13.8 5 5 5 6 5 6 6 6 6 10.4412.32 10.4412.32 10.4412.32 91610.99 9.1610.99 9.1610.99 8.1610.02 6.679.43 6.679.43 *It is possible to adjust drive so that fan speed exceeds maximum allowable. DO NOT exceed 1200 rpm. 30 Table 9G — Standard Drive Data, 60 Hz — SI UNIT MOTOR DRIVE Motor Pulley Pitch Diameter (mm) Pulley Factory Setting Full Turns Open FAN DRIVE Pulley Pitch Dia (mm) Pulley Bore (mm) Belt No. — Section Belt Pitch (mm) FAN SPEEDS (r/s) Factory Setting Range Max Allowable Speed (r/s) Change per 1⁄2 Turn of Moveable Motor Pulley Flange MAX FULL TURNS FROM CLOSED POSITION SHAFTS CENTER DISTANCE (mm) 40RM 007 40RM 40RMQ 40RMS 008 40RMS 010 40RM 40RMQ 40RMS 012 40RM 40RMS 014 40RM 40RMQ 40RMS 016 40RM 40RMS 024 40RM 40RMS 028 40RM 40RMS 034 61.086.4 71.196.5 71.196.5 86.4111.8 71.196.5 71.196.5 94.0119.4 109.2134.6 109.2134.6 2.5 2.5 2.5 2.5 2.5 2.5 3.0 3.0 3.0 224 25.4 1—A 224 25.4 1—A 224 25.4 1—A 224 25.4 1—A 229 36.5 1—A 229 36.5 1—A 239 36.5 2—B 1024 1049 1049 1074 1074 1074 1062 279 49.2 2—B* (2) 1087 (2) 1113 279 49.2 2—B* (2) 1087 (2) 1113 9.5 7.8-11.1 20.0 10.8 9.2-12.4 20.0 10.8 9.2-12.4 20.0 12.7 11.1-14.4 20.0 10.5 9.0-12.1 20.0 10.5 9.0-12.1 20.0 12.9 11.3-14.4 20.0 12.5 11.4-14.0 18.3 12.5 11.2-13.9 18.3 0.327 0.327 0.327 0.328 0.318 0.318 0.255 0.218 0.218 5 5 5 5 5 5 6 6 6 265-313 265-313 265-313 265-313 265-313 265-313 232-279 169-240 169-240 *Four belts shipped with unit. Use correct set of 2 belts sized according to the pulley setting. Table 9H — Medium-Static Drive Data, 60 Hz — SI UNIT MOTOR DRIVE Motor Pulley Pitch Diameter (mm) Pulley Factory Setting Full Turns Open FAN DRIVE Pulley Pitch Dia (mm) Pulley Bore (mm) Belt No. — Section Belt Pitch (mm) FAN SPEEDS (r/s) Factory Setting Range Max Allowable Speed (r/s) Change per 1⁄2 Turn of Moveable Motor Pulley Flange MAX FULL TURNS FROM CLOSED POSITION SHAFTS CENTER DISTANCE (mm) 40RM 007 40RM 40RMQ 40RMS 008 40RMS 010 40RM 40RMQ 40RMS 012 40RM 40RMS 014 40RM 40RMQ 40RMS 016 40RM 40RMS 024 40RM 40RMS 028 40RM 40RMS 034 86.4111.8 86.4111.8 86.4111.8 86.4111.8 86.4111.8 94.0119.4 109.2134.6 109.2134.6 109.2134.6 2.5 2.5 2.5 2.5 2.5 3.0 3.0 3.0 3.0 224 25.4 1—A 203 25.4 1—A 203 25.4 1—A 203 25.4 1—A 208 36.5 1—A 218 36.5 1—B 239 36.5 2—B 1074 1024 1024 1024 1049 1062 1062 239 49.2 2—B* (2) 986 (2) 1011 239 49.2 2—B* (2) 986 (2) 1011 12.7 11.114.4 20.0 14.0 12.215.8 20.0 14.0 12.215.8 20.0 14.0 12.215.8 20.0 13.7 11.915.4 20.0 14.0 12.415.7 20.0 14.7 13.316.4 20.0 14.7 13.316.4 18.3 14.7 13.316.4 18.3 0.328 0.360 0.360 0.360 0.352 0.278 0.255 0.255 0.255 5 5 5 5 5 6 6 6 6 265-313 265-313 265-313 265-313 265-313 265-313 232-279 169-240 169-240 *Four belts shipped with unit. Use correct set of 2 belts sized according to the pulley setting. 31 Table 9I — High-Static Drive Data, 60 Hz — SI UNIT MOTOR DRIVE Motor Pulley Pitch Diameter (mm) Pulley Factory Setting Full Turns Open FAN DRIVE Pulley Pitch Dia (mm) Pulley Bore (mm) Belt No. — Section Belt Pitch (mm) FAN SPEEDS (r/s) Factory Setting Range Max Allowable Speed (r/s) Change per 1⁄2 Turn of Moveable Motor Pulley Flange MAX FULL TURNS FROM CLOSED POSITION SHAFTS CENTER DISTANCE (mm) 40RM 007 40RM 40RMQ 40RMS 008 40RMS 010 40RM 40RMQ 40RMS 012 40RM 40RMS 014 40RM 40RMQ 40RMS 016 40RM 40RMS 024 40RM 40RMS 028 40RM 40RMS 034 86.4111.8 86.4111.8 86.4111.8 86.4111.8 94.0119.4 109.2 134.6 109.2134.6 109.2134.6 109.2134.6 2.5 2.5 2.5 2.5 3.0 3.0 3.0 3.0 3.0 178 25.4 1—A 1049 152* 25.4 1—A 947 152 25.4 1—A 947 152 25.4 1—A 947 188 36.5 1—B 1011 201 36.5 1—B 1011 188 36.5 2—B 935 203 49.2 2—B 935 203 49.2 2—B 960 16.0 14.018.1 20.0 18.7 16.320.0*† 20.0 18.7 16.320.0† 20.0 18.7 16.320.0† 20.0 16.3 14.418.3 20.0 17.7 15.819.5 20.0 18.6 16.920.0† 20.0 17.1 14.617.9 18.3 17.1 14.617.9 18.3 0.410 0.478 0.478 0.478 0.323 0.307 0.323 0.278 0.278 5 5 5 5 6 6 6 6 6 265-313 265-313 265-313 265-313 265-313** 232-279 207-255 169-240 169-240 *Values for 3-phase motor shown. For single-phase motor, pulley pitch diameter is 178 mm and resulting fan speed is 14.0-18.3 r/s. †It is possible to adjust drive so that fan speed exceeds maximum allowable. DO NOT exceed 20 r/s. **575-v unit has a center distance of 233-279. Table 9J — Standard Drive Data, 50 Hz — SI UNIT MOTOR DRIVE Motor Pulley Pitch Diameter (mm) Pulley Factory Setting Full Turns Open FAN DRIVE Pulley Pitch Dia (mm) Pulley Bore (mm) Belt No. — Section Belt Pitch (mm) FAN SPEEDS (r/s) Factory Setting Range Max Allowable Speed (r/s) Change per 1⁄2 Turn of Moveable Motor Pulley Flange MAX FULL TURNS FROM CLOSED POSITION SHAFTS CENTER DISTANCE (mm) 40RM 007 40RM 40RMQ 40RMS 008 40RMS 010 40RM 40RMQ 40RMS 012 40RM 40RMS 014 40RM 40RMQ 40RMS 016 40RM 40RMS 024 40RM 40RMS 028 40RM 40RMS 034 61.086.4 71.196.5 71.196.5 86.4111.8 86.4111.8 86.4111.8 109.2134.6 109.2134.6 109.2134.6 2.5 2.5 2.5 2.5 2.5 2.5 3.0 3.0 3.0 203 25.4 1—A 998 203 25.4 1—A 998 203 25.4 1—A 998 203 25.4 1—A 1024 229 36.5 1—A 1074 229 36.5 1—A 1074 218 36.5 1—B 1062 279 49.2 2—B 1113 279 49.2 2—B 1113 8.6 7.110.1 20.0 9.8 8.311.3 20.0 9.8 8.311.3 20.0 11.6 10.113.1 20.0 10.3 9.011.6 20.0 10.3 9.011.6 20.0 13.3 11.914.6 20.0 10.4 9.311.5 18.3 10.4 9.311.5 18.3 0.297 0.297 0.297 0.297 0.265 0.265 0.230 0.180 0.180 5 5 5 5 5 5 6 6 6 265-313 265-313 265-313 265-313 265-313 265-313 232-279 169-240 169-240 32 Table 9K — Medium-Static Drive Data, 50 Hz — SI UNIT MOTOR DRIVE Motor Pulley Pitch Diameter (mm) Pulley Factory Setting Full Turns Open FAN DRIVE Pulley Pitch Dia (mm) Pulley Bore (mm) Belt No. — Section Belt Pitch (mm) FAN SPEEDS (r/s) Factory Setting Range Max Allowable Speed (r/s) Change per 1⁄2 Turn of Moveable Motor Pulley Flange MAX FULL TURNS FROM CLOSED POSITION SHAFTS CENTER DISTANCE (mm) 40RM 007 40RM 40RMQ 40RMS 008 40RMS 010 40RM 40RMQ 40RMS 012 40RM 40RMS 014 40RM 40RMQ 40RMS 016 40RM 40RMS 024 40RM 40RMS 028 40RM 40RMS 034 86.4111.8 86.4111.8 86.4111.8 86.4111.8 86.4111.8 94.0119.4 101.6127.0 109.2134.6 109.2134.6 2.5 2.5 2.5 2.5 2.5 3.0 2.5 3.0 3.0 203 25.4 1—A 1024 178 25.4 1—A 1049 178 25.4 1—A 1049 152 25.4 1—A 947 191 36.5 1—A 998 201 36.5 1—B 1011 178 36.5 2—A 922 239 49.2 2—B 1011 239 49.2 2—B 1011 11.6 10.113.1 20.0 13.2 11.514.9 20.0 13.2 11.514.9 20.0 15.4 13.517.4 20.0 12.4 10.813.9 20.0 12.6 11.114.1 20.0 15.3 13.617.0 20.0 12.1 10.913.4 18.3 12.1 10.913.4 18.3 0.297 0.340 0.340 0.395 0.317 0.252 0.340 0.210 0.210 5 5 5 5 5 6 5 6 6 265-313 265-313 265-313 265-313 265-313 232-279 232-279 169-240 169-240 Table 9L — High-Static Drive Data, 50 Hz — SI UNIT MOTOR DRIVE Motor Pulley Pitch Diameter (mm) Pulley Factory Setting Full Turns Open FAN DRIVE Pulley Pitch Dia (mm) Pulley Bore (mm) Belt No. — Section Belt Pitch (mm) FAN SPEEDS (r/s) Factory Setting Range Max Allowable Speed (r/s) Change per 1⁄2 Turn of Moveable Motor Pulley Flange MAX FULL TURNS FROM CLOSED POSITION SHAFTS CENTER DISTANCE (mm) 40RM 007 40RM 40RMQ 40RMS 008 40RMS 010 40RM 40RMQ 40RMS 012 40RM 40RMS 014 40RM 40RMQ 40RMS 016 40RM 40RMS 024 40RM 40RMS 028 40RM 40RMS 034 86.4111.8 86.4111.8 86.4111.8 101.6127.0 86.4111.8 101.6127.0 101.6127.0 109.2134.6 109.2134.6 2.5 2.5 2.5 3.0 2.5 3.0 3.0 3.0 3.0 152 25.4 1—A 947 140 25.4 1—A 947 140 25.4 1—A 947 140 25.4 1—A 922 152 36.5 2—A 922 178 36.5 2—A 998 163 36.5 2—A 871 203 49.2 2—B 935 218 49.2 2—B 960 15.4 13.517.4 20.0 16.8 14.719.0 20.0 16.8 14.719.0 20.0 19.4 17.320.0* 20.0 15.4 13.517.4 20.0 15.3 13.617.0 20.0 16.7 14.918.6 20.0 14.3 12.815.7 18.3 13.3 11.914.6 18.3 0.395 0.432 0.432 0.360 0.395 0.283 0.308 0.247 0.230 5 5 5 6 5 6 6 6 6 265-313 265-313 265-313 234-279 232-279 232-279 207-255 169-240 169-240 *It is possible to adjust drive so that fan speed exceeds maximum allowable. DO NOT exceed 20 r/s. 33 Table 10A — Fan Performance Data — 0.0-1.2 in. wg ESP — English UNIT 40RM 007 40RM 40RMQ 40RMS 008 40RMS 010 40RM 40RMS 012 40RMQ 012 40RM 40RMS 014 40RM 40RMS 016 40RMQ 016 40RM 40RMS 024 40RM 40RMS 028 40RM 40RMS 034 AIRFLOW (Cfm) 1,800 2,100 2,400 2,700 3,000 2,250 2,600 3,000 3,400 3,750 2,550 2,975 3,400 3,825 4,250 3,000 3,500 4,000 4,500 5,000 3,000 3,500 4,000 4,500 5,000 3,750 4,300 5,000 5,700 6,250 4,500 5,300 6,000 6,800 7,500 4,500 5,300 6,000 6,800 7,500 6,000 7,000 8,000 9,000 10,000 7,500 8,750 10,000 11,250 12,500 9,000 10,500 12,000 13,500 15,000 0.0 Rpm Bhp 320 0.22 373 0.31 427 0.42 480 0.54 533 0.69 359 0.32 415 0.45 478 0.62 542 0.82 598 1.03 396 0.42 462 0.60 527 0.80 593 1.05 659 1.33 444 0.58 518 0.82 592 1.11 666 1.44 740 1.83 471 0.61 550 0.87 628 1.17 706 1.53 785 1.93 363 0.37 416 0.53 484 0.81 552 1.17 605 1.51 391 0.51 460 0.80 521 1.13 590 1.60 651 2.10 405 0.54 476 0.85 539 1.20 611 1.69 674 2.22 503 1.07 586 1.64 670 2.37 754 3.28 838 4.39 412 1.15 481 1.76 549 2.55 618 3.52 687 4.71 471 1.78 550 2.72 628 3.93 707 5.44 785 7.27 0.2 Rpm Bhp 442 0.32 483 0.42 526 0.53 570 0.67 616 0.82 472 0.44 516 0.57 569 0.75 624 0.95 673 1.17 502 0.54 556 0.72 612 0.93 670 1.18 729 1.47 541 0.71 604 0.95 669 1.25 735 1.59 803 1.98 564 0.74 632 1.00 701 1.31 772 1.67 845 2.08 475 0.58 517 0.78 573 1.08 631 1.47 678 1.83 495 0.75 551 1.08 602 1.43 663 1.93 718 2.45 507 0.79 566 1.13 620 1.50 683 2.03 740 2.58 587 1.37 660 1.98 735 2.74 812 3.69 891 4.83 492 1.53 550 2.17 610 2.99 672 4.00 735 5.22 539 2.17 608 3.15 679 4.40 752 5.94 826 7.81 EXTERNAL STATIC PRESSURE (in. wg) 0.4 0.6 0.8 Rpm Bhp Rpm Bhp Rpm Bhp 534 0.42 611 0.52 678 0.61 569 0.53 642 0.63 708 0.73 606 0.64 676 0.75 739 0.86 646 0.78 712 0.89 773 1.00 687 0.94 750 1.05 808 1.16 560 0.55 634 0.65 700 0.75 599 0.68 669 0.79 732 0.90 645 0.86 712 0.98 773 1.09 695 1.08 758 1.20 815 1.31 740 1.29 800 1.42 855 1.60 586 0.65 658 0.76 722 0.87 634 0.84 701 0.95 762 1.06 684 1.06 748 1.18 806 1.30 737 1.31 797 1.44 852 1.56 791 1.60 848 1.73 901 1.86 621 0.83 691 0.94 753 1.05 677 1.08 742 1.20 801 1.32 736 1.38 797 1.51 853 1.63 797 1.72 854 1.86 907 1.99 861 2.12 914 2.26 964 2.39 642 0.86 710 0.97 771 1.09 703 1.13 766 1.25 824 1.37 766 1.44 825 1.57 879 1.69 832 1.81 887 1.94 938 2.07 900 2.22 952 2.36 1000 2.50 566 0.80 645 1.02 715 1.24 601 1.02 676 1.26 743 1.50 650 1.35 719 1.62 782 1.89 702 1.76 766 2.06 826 2.36 744 2.15 805 2.47 862 2.79 581 1.00 657 1.25 725 1.50 629 1.35 700 1.63 764 1.91 675 1.73 741 2.04 801 2.34 730 2.26 791 2.59 847 2.92 779 2.81 837 3.16 890 3.52 592 1.03 667 1.28 735 1.54 643 1.40 713 1.68 776 1.97 691 1.81 756 2.11 816 2.42 748 2.36 809 2.69 865 3.03 800 2.93 857 3.29 910 3.65 661 1.67 727 1.97 789 2.28 726 2.31 787 2.65 844 2.99 795 3.12 851 3.49 904 3.86 867 4.09 918 4.50 967 4.90 941 5.27 988 5.70 1034 6.14 568 2.00 640 2.56 710 3.22 616 2.66 680 3.22 742 3.86 669 3.50 726 4.07 782 4.70 725 4.53 777 5.12 827 5.76 783 5.78 830 6.38 876 7.04 604 2.63 667 3.17 728 3.78 665 3.64 720 4.18 774 4.79 730 4.92 779 5.48 827 6.09 797 6.49 841 7.08 885 7.71 867 8.39 907 9.01 947 9.66 See Legend and Notes on page 36. 34 1.0 Rpm 739 767 796 828 862 759 790 828 869 906 780 818 860 904 950 809 855 904 956 1010 827 877 930 987 1045 779 805 841 881 915 787 823 858 901 941 797 835 872 918 960 846 898 954 1014 1077 776 802 836 876 922 788 827 874 928 986 Bhp 0.70 0.82 0.96 1.11 1.28 0.86 1.01 1.20 1.43 1.66 0.97 1.18 1.41 1.68 1.98 1.17 1.44 1.75 2.12 2.53 1.20 1.49 1.82 2.20 2.63 1.47 1.74 2.16 2.66 3.11 1.76 2.20 2.65 3.26 3.88 1.80 2.26 2.73 3.37 4.02 2.59 3.33 4.23 5.31 6.85 3.98 4.58 5.40 6.45 7.74 4.46 5.45 6.76 8.38 10.35 1.2 Rpm 795 821 849 880 912 814 843 879 918 954 833 870 910 952 997 862 906 953 1003 1055 878 926 978 1032 1089 839 862 896 934 966 845 878 911 951 990 854 890 924 968 1008 900 948 1001 1059 1120 840 860 889 925 966 845 878 921 970 1024 Bhp 0.80 0.92 1.06 1.21 1.39 0.96 1.11 1.32 1.55 1.78 1.08 1.29 1.53 1.80 2.11 1.28 1.56 1.88 2.24 2.66 1.31 1.60 1.94 2.33 2.76 1.69 1.99 2.44 2.96 3.43 2.02 2.48 2.96 3.60 4.24 2.06 2.55 3.05 3.71 4.38 2.90 3.67 4.61 5.72 7.02 4.83 5.38 6.17 7.21 8.49 5.22 6.18 7.47 9.10 11.07 Table 10B — Fan Performance Data — 1.4-2.4 in. wg ESP — English UNIT 40RM 007 40RM 40RMQ 40RMS 008 40RMS 010 40RM 40RMS 012 40RMQ 012 40RM 40RMS 014 40RM 40RMS 016 40RMQ 016 40RM 40RMS 024 40RM 40RMS 028 40RM 40RMS 034 AIRFLOW (Cfm) 1,800 2,100 2,400 2,700 3,000 2,250 2,600 3,000 3,400 3,750 2,550 2,975 3,400 3,825 4,250 3,000 3,500 4,000 4,500 5,000 3,000 3,500 4,000 4,500 5,000 3,750 4,300 5,000 5,700 6,250 4,500 5,300 6,000 6,800 7,500 4,500 5,300 6,000 6,800 7,500 6,000 7,000 8,000 9,000 10,000 7,500 8,750 10,000 11,250 12,500 9,000 10,500 12,000 13,500 15,000 1.4 Rpm 847 872 899 928 959 865 893 928 965 1000 884 919 957 998 1041 911 953 999 1047 1097 927 973 1023 1075 1130 894 916 948 984 1014 899 930 961 999 1036 908 941 974 1015 1054 950 996 1047 1102 1160 903 917 941 972 1010 901 928 966 1011 1062 1.6 Bhp 0.89 1.02 1.16 1.32 1.49 1.06 1.22 1.43 1.66 1.90 1.18 1.40 1.64 1.92 2.23 1.39 1.67 2.00 2.37 2.79 1.43 1.72 2.06 2.45 2.90 1.91 2.23 2.71 3.25 3.75 2.29 2.78 3.28 3.94 4.60 2.33 2.84 3.36 4.05 4.75 3.21 4.02 4.99 6.13 7.46 5.79 6.26 7.01 8.02 9.29 6.07 6.98 8.24 9.86 11.84 Rpm 896 920 946 974 1004 913 940 973 1010 1043 931 965 1002 1041 1083 958 998 1042 1089 1138 973 1018 1066 1116 1170 947 967 997 1031 1060 951 980 1009 1045 1080 959 991 1022 1061 1098 999 1042 1091 1143 1200 963 972 991 1019 1053 955 978 1011 1052 — EXTERNAL STATIC PRESSURE (in. wg) 1.8 2.0 Bhp Rpm Bhp Rpm Bhp 0.98 942 1.07 986 1.16 1.11 965 1.21 1008 1.30 1.26 990 1.36 1033 1.46 1.42 1018 1.52 1059 1.63 1.60 1046 1.71 1087 1.81 1.16 958 1.27 1001 1.37 1.33 984 1.43 1027 1.54 1.54 1017 1.65 1058 1.76 1.78 1052 1.89 1092 2.00 2.02 1084 2.13 1124 2.25 1.29 975 1.40 1018 1.50 1.51 1009 1.62 1050 1.73 1.76 1044 1.87 1085 1.98 2.04 1082 2.16 1122 2.27 2.35 1123 2.48 1161 2.60 1.50 1002 1.61 1044 1.72 1.79 1041 1.90 1082 2.02 2.12 1084 2.24 1124 2.36 2.50 1129 2.62 1168 2.74 2.92 1177 3.05 — — 1.54 1017 1.65 1058 1.76 1.84 1060 1.95 1101 2.07 2.19 1107 2.31 1146 2.43 2.58 1156 2.71 1194 2.83 3.03 — — — — 2.14 996 2.37 1044 2.60 2.48 1016 2.73 1062 2.98 2.98 1044 3.26 1089 3.53 3.55 1076 3.86 1120 4.16 4.07 1104 4.39 1147 4.71 2.56 999 2.84 1046 3.12 3.08 1027 3.38 1072 3.68 3.60 1055 3.92 1098 4.24 4.28 1089 4.63 1132 4.98 4.97 1123 5.34 1164 5.71 2.61 1008 2.89 1054 3.17 3.14 1038 3.45 1082 3.75 3.69 1067 4.01 1111 4.34 4.40 1104 4.75 1146 5.10 5.12 1140 5.49 1181 5.86 3.53 1045 3.85 1089 4.17 4.37 1086 4.72 1129 5.07 5.37 1133 5.75 1173 6.13 6.54 1183 6.96 — — 7.91 — — — — 6.83 1021 7.98 1078 9.21 7.22 1025 8.26 1078 9.38 7.91 1040 8.89 1089 9.93 8.89 1064 9.83 — — 10.15 1095 11.05 — — 6.98 1008 7.98 1060 9.05 7.84 1026 8.76 1073 9.74 9.07 1055 9.95 1098 10.88 10.67 1092 11.52 — — — — — — — See Legend and Notes on page 36. 35 2.2 Rpm 1027 1050 1073 1099 1126 1042 1067 1098 1131 1162 1059 1090 1124 1160 1199 1084 1122 1162 — — 1098 1139 1184 — — 1089 1107 1133 1162 1188 1091 1116 1141 1173 — 1098 1126 1153 1187 — 1131 1169 — — — — — — — — — — — — — 2.4 Bhp 1.25 1.40 1.55 1.73 1.92 1.47 1.65 1.87 2.12 2.37 1.61 1.84 2.10 2.39 2.72 1.83 2.13 2.48 — — 1.87 2.18 2.55 — — 2.83 3.24 3.81 4.46 5.03 3.41 3.99 4.57 5.33 — 3.46 4.06 4.67 5.46 — 4.50 5.43 — — — — — — — — — — — — — Rpm — — — — — — — — — — — — — — — 1123 1159 1199 — — 1137 1177 — — — — — — — — 1133 1157 1181 — — 1141 1167 1193 — — 1172 — — — — — — — — — — — — — — Bhp — — — — — — — — — — — — — — — 1.94 2.25 2.60 — — 1.98 2.30 — — — — — — — — 3.70 4.30 4.91 — — 3.75 4.38 5.00 — — 4.83 — — — — — — — — — — — — — — Legend and Notes for Table 10A and 10B LEGEND Bhp — Brake Horsepower Input to Fan ESP — External Static Pressure Factory-Supplied Filter Pressure Drop — English 40RM 007 AIRFLOW (Cfm) 1,800 2,400 3,000 PRESSURE DROP (in. wg) 0.05 0.08 0.11 40RM 40RMQ 40RMS 008 2,250 3,000 3,750 0.07 0.11 0.15 40RMS 010 2,550 3,400 4,250 0.09 0.13 0.18 3,000 4,000 5,000 0.11 0.17 0.23 3,750 5,000 6,250 0.06 0.10 0.13 4,500 6,000 7,500 0.08 0.12 0.17 6,000 8,000 10,000 7,500 10,000 12,500 9,000 12,000 15,000 0.12 0.19 0.26 0.15 0.22 0.30 0.19 0.29 0.40 UNIT NOTES: 1. Maximum allowable fan speed is 1100 rpm for unit sizes 028 and 034; 1200 rpm for all other sizes. 2. Fan performance is based on deductions for wet coil, clean 2-in. filters, and unit casing. See right for factory-supplied filter pressure drop. 3. Refer to fan motor and drive tables for additional data. 40RM 40RMQ 40RMS 012 40RM 40RMS 014 40RM 40RMQ 40RMS 016 40RM 40RMS 024 40RM 40RMS 028 40RM 40RMS 034 36 Table 10C — Fan Performance Data — 0-300 Pa ESP — SI UNIT 40RM 007 40RM 40RMQ 40RMS 008 40RMS 010 40RM 40RMS 012 40RMQ 012 40RM 40RMS 014 40RM 40RMS 016 40RMQ 016 40RM 40RMS 024 40RM 40RMS 028 40RM 40RMS 034 AIRFLOW (L/s) 850 1000 1150 1300 1450 1000 1200 1400 1600 1800 1200 1400 1600 1800 2000 1450 1670 1900 2120 2350 1450 1670 1900 2120 2350 1750 2050 2350 2650 2950 2100 2450 2800 3150 3500 2100 2450 2800 3150 3500 2900 3350 3800 4250 4700 3500 4100 4700 5300 5900 4250 4950 5650 6350 7050 0 r/s 5.34 6.28 7.22 8.17 9.11 5.63 6.76 7.89 9.01 10.10 6.58 7.67 8.77 9.86 11.0 7.58 8.73 9.93 11.10 12.30 8.04 9.26 10.50 11.80 13.00 5.99 7.01 8.04 9.07 10.10 6.43 7.51 8.58 9.65 10.70 6.65 7.76 8.87 9.98 11.10 8.58 9.91 11.30 12.60 13.90 6.79 7.95 9.12 10.30 11.40 7.86 9.15 10.40 11.70 13.00 50 kW 0.17 0.24 0.33 0.43 0.55 0.22 0.32 0.46 0.62 0.80 0.31 0.44 0.60 0.78 0.99 0.46 0.63 0.84 1.08 1.36 0.49 0.67 0.89 1.14 1.43 0.27 0.41 0.60 0.84 1.13 0.37 0.57 0.82 1.14 1.52 0.39 0.60 0.86 1.19 1.59 0.86 1.28 1.81 2.46 3.24 0.84 1.29 1.88 2.62 3.52 1.33 2.03 2.92 4.02 5.37 r/s 7.38 8.10 8.86 9.64 10.50 7.61 8.49 9.42 10.40 11.40 8.35 9.25 10.20 11.10 12.10 9.18 10.20 11.20 12.20 13.30 9.57 10.60 11.80 12.90 14.00 7.88 8.68 9.53 10.40 11.30 8.19 9.06 9.96 10.90 11.90 8.39 9.30 10.20 11.20 12.20 9.96 11.10 12.30 13.60 14.80 8.14 9.12 10.10 11.20 12.30 8.99 10.10 11.30 12.50 13.70 kW 0.25 0.32 0.41 0.52 0.64 0.30 0.41 0.55 0.71 0.90 0.40 0.54 0.70 0.88 1.09 0.56 0.73 0.95 1.18 1.17 0.58 0.77 0.99 1.24 1.54 0.43 0.60 0.81 1.06 1.37 0.55 0.77 1.05 1.38 1.78 0.58 0.81 1.09 1.44 1.86 1.09 1.53 2.09 2.76 3.57 1.12 1.60 2.21 3.00 3.90 1.63 2.35 3.27 4.40 5.77 EXTERNAL STATIC PRESSURE (Pa) 100 150 200 r/s kW r/s kW r/s kW 8.91 0.32 10.20 0.39 11.30 0.46 9.53 0.40 10.80 0.48 11.80 0.55 10.20 0.50 11.40 0.58 12.40 0.66 10.90 0.61 12.00 0.69 13.00 0.77 11.60 0.73 12.70 0.82 13.60 0.91 9.11 0.38 10.40 0.45 11.50 0.53 9.88 0.50 11.10 0.57 12.10 0.66 10.70 0.64 11.80 0.72 12.80 0.81 11.60 0.80 12.60 0.89 13.60 0.98 12.50 0.10 13.50 1.09 14.40 1.18 9.76 0.49 11.00 0.57 12.00 0.65 10.60 0.63 11.70 0.71 12.70 0.80 11.40 0.79 12.50 0.88 13.40 0.97 12.30 0.98 13.30 1.07 14.20 1.16 13.20 1.19 14.10 1.29 15.00 3.38 10.50 0.65 11.60 0.73 12.70 0.82 11.40 0.83 12.50 0.92 13.40 1.01 12.30 1.05 13.30 1.14 14.30 1.24 13.30 1.29 14.20 1.39 15.10 1.48 14.30 1.57 15.20 1.68 16.00 1.78 10.90 0.67 12.00 0.76 13.00 0.85 11.80 0.86 12.90 0.95 13.80 1.04 12.80 1.09 13.80 1.19 14.70 1.28 13.90 1.35 14.80 1.45 15.60 1.55 15.00 1.65 15.80 1.75 16.60 1.85 9.41 0.59 10.70 0.75 11.90 0.92 10.10 0.78 11.30 0.96 12.40 1.14 10.80 1.01 12.00 1.21 13.00 1.41 11.60 1.28 12.70 1.50 13.70 1.72 12.40 1.61 13.40 1.85 14.40 2.08 9.65 0.73 10.90 0.92 12.10 1.11 10.40 0.97 11.60 1.18 12.70 1.39 11.20 1.27 12.30 1.49 13.30 1.72 12.00 1.63 13.10 1.87 14.00 2.12 12.90 2.05 13.90 2.31 14.80 2.58 9.83 0.76 11.10 0.95 12.20 1.13 10.60 1.01 11.80 1.22 12.90 1.43 11.50 1.32 12.50 1.55 13.60 1.78 12.30 1.70 13.40 1.95 14.30 2.20 13.20 2.14 14.20 2.41 15.10 2.68 11.20 1.32 12.30 1.55 13.30 1.78 12.20 1.79 13.20 2.04 14.20 2.30 13.30 2.37 14.30 2.64 15.10 2.93 14.50 3.07 15.30 3.37 16.10 3.67 15.60 3.90 16.40 4.22 17.20 4.55 9.42 1.47 10.70 1.89 11.80 2.39 10.20 1.96 11.30 2.38 12.40 2.86 11.10 2.59 12.10 3.02 13.00 3.49 12.10 3.37 12.90 3.81 13.80 4.29 13.10 4.32 13.90 4.77 14.60 5.26 10.10 1.97 11.10 2.37 12.20 2.83 11.10 2.72 12.00 3.12 12.90 3.58 12.20 3.66 13.00 4.08 13.80 4.54 13.30 4.81 14.00 5.25 14.70 5.72 14.40 6.21 15.10 6.66 15.70 7.15 See Legend and Notes on page 39. 37 250 r/s kW 12.30 0.53 12.80 0.63 13.40 0.73 13.90 0.85 14.50 0.99 12.50 0.61 13.10 0.74 13.80 0.89 14.50 1.07 15.20 1.27 13.00 0.73 13.60 0.88 14.30 1.05 15.10 1.25 15.80 1.48 13.60 0.90 14.30 1.10 15.10 1.33 15.90 1.58 16.80 1.88 13.90 0.93 14.70 1.13 15.60 1.38 16.40 1.64 17.40 1.95 13.00 1.08 13.50 1.33 14.00 1.61 14.60 1.94 15.30 2.32 13.10 1.30 13.70 1.60 14.30 1.95 14.90 2.36 15.60 2.84 13.30 1.31 13.80 1.63 14.50 2.01 15.20 2.45 15.90 2.95 14.20 2.01 15.10 2.55 16.00 3.21 16.90 3.98 17.90 4.88 12.90 2.96 13.40 3.40 13.90 4.02 14.60 4.82 15.40 5.79 13.20 3.34 13.80 4.08 14.60 5.04 15.50 6.23 16.40 7.67 300 r/s kW 13.30 0.60 13.70 0.70 14.20 0.81 14.80 0.93 15.40 1.07 13.40 0.68 14.00 0.82 14.60 0.97 15.30 1.16 16.00 1.36 13.90 0.81 14.50 0.96 15.20 1.14 15.90 1.34 16.60 1.57 14.50 0.99 15.20 1.18 15.90 1.42 16.70 1.68 17.60 1.98 14.80 1.02 15.50 1.22 16.40 1.47 17.20 1.74 18.10 2.05 14.00 1.25 14.40 1.51 14.90 1.82 15.50 2.16 16.10 2.56 14.10 1.50 14.60 1.81 15.10 2.18 15.80 2.61 16.40 3.11 14.20 1.50 14.80 1.84 15.40 2.24 16.00 2.70 16.70 3.22 15.10 2.25 15.90 2.81 16.80 3.49 17.70 4.28 18.60 5.21 14.00 3.61 14.30 4.00 14.80 4.60 15.40 5.38 16.10 6.35 14.10 3.92 14.70 4.62 15.40 5.57 16.20 6.77 17.10 8.21 Table 10D — Fan Performance Data — 350-600 Pa ESP — SI UNIT 40RM 007 40RM 40RMQ 40RMS 008 40RMS 010 40RM 40RMS 012 40RMQ 012 40RM 40RMS 014 40RM 40RMS 016 40RMQ 016 40RM 40RMS 024 40RM 40RMS 028 40RM 40RMS 034 AIRFLOW (L/s) 850 1000 1150 1300 1450 1000 1200 1400 1600 1800 1200 1400 1600 1800 2000 1450 1670 1900 2120 2350 1450 1670 1900 2120 2350 1750 2050 2350 2650 2950 2100 2450 2800 3150 3500 2100 2450 2800 3150 3500 2900 3350 3800 4250 4700 3500 4100 4700 5300 5900 4250 4950 5650 6350 7050 350 r/s 14.10 14.60 15.10 15.60 16.10 14.30 14.80 15.40 16.10 16.80 14.70 15.30 16.00 16.60 17.30 15.30 16.00 16.70 17.50 18.30 15.60 16.30 17.10 17.90 18.80 14.90 15.30 15.80 16.30 16.90 15.00 15.50 16.00 16.60 17.20 15.10 15.60 16.20 16.80 17.50 16.00 16.70 17.50 18.40 19.30 15.10 15.30 15.70 16.20 16.90 15.00 15.50 16.10 16.90 17.70 400 kW 0.67 0.77 0.88 1.01 1.15 0.76 0.90 1.06 1.24 1.45 0.89 1.05 1.23 1.43 1.66 1.07 1.27 1.51 1.77 2.07 1.10 1.31 1.56 1.83 2.15 1.42 1.70 2.02 2.39 2.80 1.70 2.03 2.42 2.87 3.38 1.68 2.05 2.47 2.95 3.49 2.49 3.08 3.77 4.59 5.54 4.33 4.67 5.23 5.99 6.95 4.55 5.22 6.16 7.34 8.79 r/s 15.00 15.40 15.90 16.40 16.90 15.10 15.60 16.20 16.80 17.50 15.50 16.10 16.70 17.40 18.00 16.10 16.70 17.40 18.20 19.00 16.30 17.00 17.80 18.60 19.50 15.80 16.20 16.60 17.10 17.70 15.80 16.30 16.80 17.40 18.00 16.00 16.40 17.00 17.60 18.20 16.80 17.50 18.20 19.10 20.00 16.10 16.20 16.50 17.00 17.60 16.00 16.30 16.90 17.50 18.30 kW 0.74 0.84 0.96 1.09 1.24 0.83 0.98 1.14 1.33 1.54 0.97 1.13 1.31 1.52 1.76 1.15 1.36 1.60 1.86 2.17 1.18 1.40 1.65 1.93 2.25 1.58 1.88 2.22 2.61 3.04 1.90 2.25 2.66 3.12 3.65 1.87 2.25 2.69 3.19 3.76 2.73 3.34 4.06 4.90 5.87 5.12 5.39 5.91 6.65 7.59 5.24 5.86 6.77 7.94 9.39 EXTERNAL STATIC 450 r/s kW 15.70 0.81 16.10 0.91 16.60 1.03 17.10 1.17 17.60 1.32 15.80 0.91 16.40 1.05 16.90 1.22 17.50 1.41 18.20 1.63 16.30 1.05 16.80 1.21 17.40 1.40 18.10 1.61 18.70 1.85 16.80 1.24 17.40 1.44 18.10 1.69 18.80 1.96 19.60 2.27 17.10 1.27 17.80 1.48 18.50 1.74 19.30 2.02 — — 16.60 1.75 17.00 2.07 17.40 2.43 17.90 2.83 18.40 3.28 16.70 2.11 17.10 2.47 17.60 2.90 18.10 3.38 18.70 3.93 16.80 2.06 17.20 2.46 17.80 2.92 18.30 3.44 19.00 4.03 17.50 2.97 18.20 3.61 18.90 4.35 19.80 5.21 — — 17.10 5.98 17.10 6.18 17.40 6.64 17.80 7.35 18.30 8.27 16.80 5.99 17.10 6.56 17.60 7.43 18.20 8.58 — — See Legend and Notes on page 39. 38 PRESSURE (Pa) 500 r/s kW 16.50 0.87 16.90 0.98 17.30 1.11 17.80 1.25 18.30 1.40 16.60 0.99 17.10 1.13 17.60 1.30 18.20 1.50 18.90 1.72 17.00 1.12 17.50 1.29 18.10 1.48 18.70 1.70 19.40 1.94 17.50 1.32 18.10 1.53 18.80 1.78 19.50 2.05 — — 17.80 1.35 18.40 1.57 19.20 1.83 19.90 2.11 — — 17.40 1.93 17.80 2.26 18.20 2.64 18.60 3.06 19.10 3.53 17.40 2.32 17.80 2.70 18.30 3.14 18.80 3.64 19.40 4.20 17.50 2.24 18.00 2.67 18.50 3.15 19.00 3.69 19.60 4.30 18.30 3.22 18.90 3.87 19.60 4.64 — — — — 18.00 6.92 18.00 7.02 18.20 7.43 — — — — 17.70 6.79 17.90 7.30 18.30 8.13 — — — — 550 r/s 17.20 17.60 18.00 18.40 18.90 17.30 17.80 18.30 18.90 19.50 17.70 18.20 18.80 19.40 — 18.20 18.80 19.40 — — 18.40 19.10 19.80 — — 18.20 18.50 18.90 19.30 19.80 18.20 18.60 19.00 19.50 — 18.30 18.70 19.20 19.70 — 19.00 19.60 — — — — — — — — — — — — — kW 0.94 1.06 1.18 1.32 1.48 1.06 1.21 1.39 1.58 1.80 1.20 1.37 1.57 1.79 — 1.40 1.62 1.87 — — 1.43 1.66 1.92 — — 2.10 2.45 2.84 3.28 3.77 2.53 2.93 3.38 3.90 — 2.43 2.88 3.38 3.94 — 3.47 4.14 — — — — — — — — — — — — — 600 r/s — — — — — — — — — — — — — — — 18.80 19.40 — — — 19.10 19.70 — — — — — — — — 18.90 19.30 19.70 — — 19.00 19.40 19.80 — — 19.70 — — — — — — — — — — — — — — kW — — — — — — — — — — — — — — — 1.48 1.70 — — — 1.52 1.74 — — — — — — — — 2.74 3.16 3.63 — — 2.62 3.09 3.61 — — 3.72 — — — — — — — — — — — — — — Legend and Notes for Tables 10C and 10D Replacing Filters — Filters can be removed and installed from either side of the unit. Install new filters in units that have one fan as follows: 1. Remove the side access panel (retain screws). 2. Remove the filter retainer clip. 3. Remove old filters by tilting them and lifting them out of the filter track. See Fig. 12 and 22. 4. Reverse the procedure to install new filters. LEGEND ESP — External Static Pressure NOTES: 1. Maximum allowable fan speed is 18.3 r/s for unit sizes 028 and 034; 20 r/s for all other sizes. 2. Fan performance is based on deductions for wet coil, clean 51-mm filters, and unit casing. See right for factory-supplied filter pressure drop. 3. Refer to fan motor and drive tables for additional data. To install new filters in larger units that have 2 fans, follow the preceding steps, but use the factory-supplied filter hook to slide filters within reach for removal. The filter hook is shipped inside the unit in the baserail. Factory-Supplied Filter Pressure Drop — SI 40RM 007 AIRFLOW (L/s) 850 1150 1450 PRESSURE DROP (Pa) 13 20 28 40RM 40RMQ 40RMS 008 1000 1400 1800 17 27 38 40RMS 010 1200 1600 2000 21 32 45 1450 1900 2350 28 42 56 1750 2350 2950 15 24 33 2100 2800 3500 20 30 42 2900 3800 4700 3500 4700 5900 4250 5650 7050 32 47 64 36 55 76 47 71 98 UNIT 40RM 40RMQ 40RMS 012 40RM 40RMS 014 40RM 40RMQ 40RMS 016 40RM 40RMS 024 40RM 40RMS 028 40RM 40RMS 034 Do not operate unit without air filters. Fig. 22 — Filter Removal/Replacement 39 Copyright 1995 Carrier Corporation Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 4 PC 111 Catalog No. 534-053 Printed in U.S.A. Form 40RM-9SI Pg 42 596 11-95 Replaces: 40RM-1SI Tab 3c 2e CUT ALONG DOTTED LINE CUT ALONG DOTTED LINE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - START-UP CHECKLIST (SPLIT SYSTEMS WITH 40RM/RMQ/RMS UNITS) A. Preliminary Information OUTDOOR: MODEL NO. SERIAL NO. INDOOR: MODEL NO. SERIAL NO. ADDITIONAL ACCESSORIES B. Pre-Start-Up OUTDOOR UNIT (Y/N) IS THERE ANY SHIPPING DAMAGE? IF SO, WHERE: WILL THIS DAMAGE PREVENT UNIT START-UP? (Y/N) CHECK POWER SUPPLY. DOES IT AGREE WITH UNIT? HAS THE GROUND WIRE BEEN CONNECTED? (Y/N) (Y/N) HAS THE CIRCUIT PROTECTION BEEN SIZED AND INSTALLED PROPERLY? (Y/N) ARE THE POWER WIRES TO THE UNIT SIZED AND INSTALLED PROPERLY? (Y/N) HAVE COMPRESSOR HOLDDOWN BOLTS BEEN LOOSENED? (Y/N) CONTROLS ARE THERMOSTAT(S) AND INDOOR FAN CONTROL WIRING CONNECTIONS MADE AND CHECKED? (Y/N) ARE ALL WIRING TERMINALS (including main power supply) TIGHT? (Y/N) HAVE OUTDOOR UNIT CRANKCASE HEATERS BEEN ENERGIZED FOR 24 HOURS? (Y/N) INDOOR UNIT HAS WATER BEEN PLACED IN DRAIN PAN TO CONFIRM PROPER DRAINAGE? ARE PROPER AIR FILTERS IN PLACE? (Y/N) (Y/N) HAVE FAN AND MOTOR PULLEYS BEEN CHECKED FOR PROPER ALIGNMENT? DO THE FAN BELTS HAVE PROPER TENSION? (Y/N) (Y/N) PIPING 40RM,RMQ ARE LIQUID LINE SOLENOID VALVES LOCATED AT THE INDOOR UNIT COILS AS REQUIRED? (Y/N) HAVE LEAK CHECKS BEEN MADE AT COMPRESSORS, CONDENSERS, INDOOR COILS, TXVs (Thermostatic Expansion Valves) SOLENOID VALVES, FILTER DRIERS, AND FUSIBLE PLUGS WITH A LEAK DETECTOR? (Y/N) LOCATE, REPAIR, AND REPORT ANY LEAKS. HAVE ALL COMPRESSOR SERVICE VALVES BEEN FULLY OPENED (BACKSEATED)? ARE THE COMPRESSOR OIL SIGHT GLASSES SHOWING CORRECT LEVELS? (Y/N) (Y/N) 40RMS HAS AIR BEEN BLED FROM SYSTEM? (Y/N) HAVE LEAK CHECKS BEEN MADE AT COMPRESSORS, CHILLERS, VALVES, AND INDOOR COILS? (Y/N) LOCATE, REPAIR, AND REPORT ANY LEAKS. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 4 PC 111 Catalog No. 534-053 Printed in U.S.A. Form 40RM-9SI CL-1 11-95 Replaces: 40RM-1SI Tab 3c 2e CHECK VOLTAGE IMBALANCE LINE-TO-LINE VOLTS: AB V AC (AB + AC + BC)/3 = AVERAGE VOLTAGE = V BC V V V MAXIMUM DEVIATION FROM AVERAGE VOLTAGE = VOLTAGE IMBALANCE = 100 X (MAX DEVIATION)/(AVERAGE VOLTAGE) = % IF OVER 2% VOLTAGE IMBALANCE, DO NOT ATTEMPT TO START SYSTEM! CALL LOCAL POWER COMPANY FOR ASSISTANCE. C. Start-Up CHECK EVAPORATOR FAN SPEED AND RECORD. AFTER AT LEAST 10 MINUTES RUNNING TIME, RECORD THE FOLLOWING MEASUREMENTS: COMP A1 COMP B1 OIL PRESSURE SUCTION PRESSURE SUCTION LINE TEMP DISCHARGE PRESSURE DISCHARGE LINE TEMP ENTERING OUTDOOR UNIT AIR TEMP LEAVING OUTDOOR UNIT AIR TEMP INDOOR UNIT ENTERING AIR DB TEMP INDOOR UNIT ENTERING AIR WB TEMP INDOOR UNIT LEAVING AIR DB TEMP INDOOR UNIT LEAVING AIR WB TEMP OUTDOOR UNIT ENTERING WATER TEMP (40RMS ONLY) OUTDOOR UNIT LEAVING WATER TEMP (40RMS ONLY) INDOOR UNIT ENTERING WATER TEMP (40RMS ONLY) INDOOR UNIT LEAVING WATER TEMP (40RMS ONLY) COMPRESSOR AMPS (L1/L2/L3) / / / / CHECK THE COMPRESSOR OIL LEVEL SIGHT GLASSES; ARE THE SIGHT GLASSES SHOWING OIL LEVEL AT 1⁄8 TO 1⁄3 FULL? (Y/N) NOTES: Copyright 1995 Carrier Corporation Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 4 PC 111 Catalog No. 534-053 Printed in U.S.A. Form 40RM-9SI CL-2 596 11-95 Replaces: 40RM-1SI Tab 3c 2e