Download Motorola MCP750 Technical data
Transcript
SCC - Serial Communication Controller (Z85230) Tests BAUDS - Baud Rates Command Input 3 PPCx-Diag>scc bauds Description This test transmits 256 characters at various baud rates. The data is received and compared. If any protocol errors are created or the data is not correct when received, the test failed. The bauds tested are: 1200 2400 4800 Note 9600 19200 38400 Because of the design of the Z85230, when internal loopback testing is performed, data is still transmitted out of the device on the TxD line. This may cause problems with terminals, modem, printers, and any other device attached. Response/Messages After the command has been issued, the following line is printed: SCC BAUDS: Baud Rates................... Running ---> If all parts of the test are completed correctly, then the test passes: SCC BAUDS: Baud Rates...............Running ---> PASSED If any part of the test fails, then the display appears as follows: SCC BAUDS: Baud Rates...............Running ---> FAILED SCC/BAUDS Test Failure Data: (error message) Refer to the section SCC Error Messages for a list of the error messages and their meaning. http://www.motorola.com/computer/literature 3-121