Transcript
Converting the appliance to different gas types 7.2 7.2.1 i Testing combustion air/flue gas at set heat output Testing the O2 or CO2 level in the combustion air By testing the O2 or CO2 level in the combustion air the gas tightness of a type C 13 or C33 flue system can be checked. The O2 level must not be less than 20,6 %. The CO2 level must not exceed 0,2 %. B Press and hold the button until the display shows – –. “Chimney sweep” mode is now active. The button will light up and the display shows the CH flow temperature. i In “chimney sweep” mode, the appliance switches to max. rated heat output or the set heating output. You then have 15 minutes in which to measure the levels. After that, the appliance switches back from “chimney sweep” mode to normal mode. 7.2.2 Testing CO and CO 2 B Press and hold the button until the display shows – –. “Chimney sweep” mode is now active. The button will light up and the display shows the CH flow temperature. i You have 15 minutes in which to measure the levels. After that, the appliance switches back from “chimney sweep” mode to normal mode. B Remove sealing plug from flue gas testing point (234, fig. 50). B Insert testing probe about 135 mm into the testing point and seal testing point. B CO- and CO2 levels. B Refit sealing plug. B Press and hold button until the display shows – –. The button will stop flashing and the display shows the CH flow temperature. B Remove sealing plug from combustion air testing point (234.1, fig. 50). B Insert testing probe about 80 mm into the testing point and seal testing point. 2 3 4 2 3 4 .1 6 7 2 0 6 1 0 3 3 2 -6 5 .2 R Fig. 50 B Measure O2 and CO2 levels. B Refit sealing plug. B Press and hold button until the display shows – –. The button will stop flashing and the display shows the CH flow temperature. 6 720 610 596 GB (03.02) 31