6
G3 Series
Malfunctions
Error messages
0x00017103
Temperature too high in the electronics unit.
The system may be damaged.
Temperature %0s °C.
382
The temperature in the electronics unit exceeded a critical threshold. Check that the fan is not covered. Check the fan filter and replace it if it is contaminated.
Cause
The temperature in the BF board exceeded a critical threshold. This may cause
damage to the hardware.
Solution
Switch machine off and leave to cool down. Contact service if this error occurs again.
0x00017301
Command currently not possible.
385
Instruction was not ready. Try again.
Cause
An instruction waits for commands, but is not able to process a prematurely received
command.
Solution
Try another time. Contact the service department
0x00017402
Undefined status of an instruction.
386
Programming error.
Contact service
0x00017502
Error in the slide vacuum.
No help available
0x00017704
Communication error on an internal bus (CAN).
389
No help available
Contact service
0x00017803
Incorrect slide vacuum parameter. Error index %0s
Vacuum slider parameter error.
0x00017A03
Vacuum slider current limitation.
No help available
0x00017B02
CAN message has been lost.
393
An internal communication problem occurred.
Contact service
0x00017C03
Incorrect module initialisation Status
394
Internal software error.
Contact service
0x00017D04
Operating unit has lost the communication to the MC.
CAN Tx error.
395
No help available
Contact service
0x00017E04
Operating unit has lost the communication to the MC.
CAN Rx error.
396
No help available
Contact service
0x00017F03
Error when looking for the zero mark of the T axis.
397
No help available
Contact service
6-15
000012,03,02-2009, jmu