Transcript
Up to version 2.05 only: The displayed value is saved by exiting or scrolling with one of these keys. Continued on previous page Steam boiler present: NO * old: Voltage: 230V_ Hot water: measured *new: E1-E2 locked/unlocked Activate controller for hot water/steam boiler (NTC temperature sensor, electrode etc.) Switching options: YES/NO NO = steam boiler controller off, steam boiler faults are not displayed Voltage selection (Locking of the boilers) Depends on device model (refer to rating plate). Switching options: 230 V / 400 V Switching options Japan: 200 V / 3 x 200 V Hot water metered or not metred Default setting: metered Steam dispensing switch start/stop function (adjustable from software version 2.00) Steam outlet not measured Switching options: Metered = press steam key to start, then press again to stop steam dispensing / Non−metered = keep steam key pressed for as long as steam is required. Default setting: non−metered No.Total Brewing Total.0000000000 Display of completed brewing cycles This counter cannot be deleted. Version: 3.02.044 Display of software version number Service instructions bremer VIVA, issued 1997-07 Status: 2003-03 7-3