Download Uniden U4 DB-CP Specifications
Transcript
_______________________________________________________________________________ MDPrompt text Default: (see text) Mode: Packet/MailDrop Host: Mp _________________________________ Parameters: _________________________________ text Any combination of characters and spaces up to a maximum of 80 bytes. _______________________________________________________________________________ MDPROMPT is the command line sent to a calling station by your MailDrop in response to a Send message command. The default text is: "Subject:/Enter message, ^Z (CTRL-Z) or /EX to end" Text before the first slash is sent to the user as the subject prompt; text after the slash is sent as the message text prompt. If there is no slash in the text, the subject prompt is "Subject:" and the text prompt is from MDPROMPT. _______________________________________________________________________________ MEmory "n" Default: none Mode: All Host: MM _________________________________ Parameters: _________________________________ "n" - A hexadecimal value used to access the PK-232's memory locations, or read values stored at a specified ADDRESS. _______________________________________________________________________________ The MEMORY command works with the ADDRESS command (ADDRESS $aabb) and permits access to memory locations. Use the Memory command without arguments to read a memory, and with one argument $0 to $FF to write to a memory location. The value in ADDRESS is incremented after using the MEMORY command. _______________________________________________________________________________ MFIlter n1[,n2[,n3[,n4]]] Default: $80 Mode: Morse, Baudot ASCII, AMTOR and Packet Host: MI _________________________________ Parameters: _________________________________ "n" - 0 to $80 (0 to 128 decimal) specifies an ASCII character code. Up to four characters may be specified separated by commas. _______________________________________________________________________________ Use MFILTER to select up to 4 characters to be "filtered," or excluded from Morse, Baudot, ASCII, AMTOR and monitored packets. Parameters "n1," - "n4" are the ASCII codes for the characters you want to filter. The special value of $80 (default) filters all characters above $7F and all control-characters except carriage-return ($0D), linefeed ($0A), and TAB ($09). _______________________________________________________________________________ MFrom ALL/NONE or YES/NO call1[,call2..] Default: ALL Mode: Packet Host: MF _________________________________ Parameters: _________________________________ call ALL/NONE or YES_list/NO_list (list of up to eight call signs, separated by commas). _______________________________________________________________________________ 8/91 - A-51 From The N3UJJ.COM Document Library