Download Filter Design HDL Coder User`s Guide

Transcript
HoldTime
HoldTime
Specify hold time for filter data input signals and forced reset input signals
Settings
ns
Specify the number of nanoseconds during which filter data input signals and forced
reset input signals are held past the clock rising edge. The default is 2.
The hold time is expressed as a positive integer or double (with a maximum of 6
significant digits after the decimal point).
This option applies to reset input signals only if forced resets are enabled.
Usage Notes
The hold time is the amount of time that reset input signals and input data are held
past the clock rising edge. The following figures show the application of a hold time (thold)
for reset and data input signals when the signals are forced to active high and active
low. The ResetLength property is set to its default of 2 cycles, and the reset signal is
asserted for a total of two cycles plus thold.
8-53