CARROLL TOUCH Appendix A - Smart-Frame Protocol Command Reference Report_Transfer_Off (43H) (C) Command Description The Report_Transfer_Off (43H) command stops the transmission of touch data to the host. If the transfer of a report is in process, it is completed. The touch system continues to scan until another report is generated and stored in the touch report buffer. The touch system then stops scanning and waits for the host to send either the Report_Transfer_On (44H), Get_One_Report (46H), or Clear_Touch_Report_Buffer (3DH) command. When the host sends Report_Transfer_On (44H), the touch system sends the coordinates in the touch report buffer (if any) or scans until another report is ready for transfer. The system default setting for report transfer is off. See Also Report_Transfer_On (44H) Get_One_Report (46H) Touch System Programmer’s Guide A-29