DECATHLON SERIES GAS FRYERS CHAPTER 1: SERVICE PROCEDURES 1.7.4 Replacing the High-Limit Thermostat (cont.) 8. Mark and disconnect wires at the high-limit in the component box. Mark and disconnect high-limit wiring (arrows). (Reconnect wires to the same terminals on the replacement high-limit.) 9. Remove high-limit from fryer by pulling the capillary tube and bulb through the component box opening (arrow). (This may require removal of the control panel frame.) 10. Reverse the above steps for high-limit installation. IMPORTANT: When installing new high-limit or backup thermostat, ensure the capillary tube and bulb are positioned properly with the mounting hardware installed prior to tightening the compression nut. Once tightened, the capillary tube cannot be repositioned. 1-17 Pull the capillary tube and bulb up and through the component box opening to remove old high-limit. Removing the control panel frame will facilitate high-limit removal. Replace control panel frame after new high-limit has been installed.