Setpoint channel and closed-loop control 7.4 Vector speed/torque control with/without encoder 7.4.1 Vector control without encoder Description For sensorless vector control only (SLVC: Sensorless Vector Control), the position of the flux and actual speed must be determined via the electric motor model. The model is buffered by the incoming currents and voltages. At low frequencies (approx. 0 Hz), the model cannot determine the speed. For this reason and due to uncertainties in the model parameters or inaccurate measurements, the system is switched from closed-loop to open-loop operation in this range. The changeover between closed-loop/open-loop operation is controlled on the basis of time and frequency conditions (p1755, p1756, p1758 - only for induction motors). The system does not wait for the time condition to elapse if the setpoint frequency at the ramp-function generator input and the actual frequency are below p1755 x (1 - (p1756 / 100 %)) simultaneously. Transition from open-loop to closed-loop operation always takes place when the changeover speed in p1755 (characteristic "1" in the figure below). If the speed increase is set very slow and a changeover delay time >0 is set in p1759, transition takes place after the changeover delay time (characteristic "2" in the figure below). , IBDFW , 1 S 2 S>USP@ SS>USP@ W 2SHQORRSFRQWUROOHGRSHUDWLRQ 1 &ORVHGORRSFRQWUROOHGRSHUDWLRQ S Figure 7-9 2 W Changeover conditions In open-loop operation, the calculated actual speed value is the same as the setpoint value. For vertical loads and acceleration processes, parameters p1610 (constant torque boost) and p1611 (acceleration torque boost) must be modified in order to generate the static or dynamic load torque of the drive. If, on induction motors, p1610 is set to 0%, only the magnetizing current r0331 is injected; at a value of 100%, the rated motor current p0305 is injected. For permanent-magnet synchronous motors, at p1610 = 0%, a pre-control absolute value derived from the supplementary torque r1515 remains instead of the magnetizing current. To ensure that the drive does not stall during acceleration, p1611 can be increased or acceleration pre-control for the speed controller can be used. This is also advisable to ensure that the motor is not subject to thermal overload at low speeds. 272 Drive converter cabinet units Operating Instructions, 10/2008, A5E00288214A
Related documents
Operating Instructions
Operating Instructions
A1 Control Workplace Hazards - SOL*R
Istruzioni per l`uso
Operating Instructions
Istruzioni per l`uso
Conversores de frequência montados em unidade de
Conversores de frequência montados em unidade de
Siemens SINAMICS G150 Specifications
Siemens SINAMICS G150 Specifications