Download Compaq 370 Specifications
Transcript
Diagnostics and Troubleshooting 3-13 Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Problem Recommended Action 1702 - SCSI cable error detected; system halted. None Termination or cabling problem with the system board integrated SCSI controller. Refer to cabling diagrams in Chapter 2 of this guide, the cabling guidelines on the Compaq website, and your Compaq server documentation. 1703 - SCSI cable error detected. Internal SCSI cable not attached to system board connector. System halted. None Incorrect cabling Ensure that the integrated SCSI controller has SCSI termination attached. 1720 - Slot x Drive Array—SMART hard Drive Detects Imminent Failure SCSI: Port n: SCSI ID x None Prefailure condition Indicated drive has reported a SMART predictive-failure condition and may fail at some time in the future. If drive is part of a non-fault-tolerant configuration, back up all data before replacing drive and restore all data afterward. If drive is part of a fault-tolerant configuration do not replace the drive unless all other drives in the array are online. Press F1 to resume. 1721 - Slot x Drive Array—Drive parameter tracking predicts imminent failure. The following devices should be replaced when conditions permit. Do not replace drive unless all other drives in the array are online! Back up data before replacing drive(s) if using RAID 0. None Monitor and performance threshold exceeded condition. Replace the drive when it is reasonable for you to do. The drive has not failed, but Compaq recommends you replace the drive. continued