Download Carrier WEATHER MASTER 48P2 Specifications
Transcript
APPENDIX D — VFD INFORMATION (cont) P.E. motor VFD h. Use the UP or DOWN keys to highlight the correct VFD and press OK (SOFT KEY 2). 6. The keypad will display “Carrier Assistant Complete”. The parameters in Table B will now be set correctly. Press OK (SOFT KEY 2) then EXIT (SOFT KEY 1) to return to the Main Menu. Press EXIT (SOFT KEY 1) again to return to the Standard Display mode. 7. To allow the configuration parameters in Tables C and D to be sent to the VFD, power must be cycled to the drive. Cycle power using Service Test mode. a. For Supply Fan VFD, set Service TestoFANSoS.FAN = OFF. Allow VFD to power down completely (approximately 30 seconds) and then turn back ON. b. For Exhaust Fan VFD, set Service TestoFANSoP.E.1 = OFF. Allow VFD to power down completely (approximately 30 seconds) and then turn back ON. 8. Press the AUTO button on VFD Keypad. 9. Take the Comfortlink controls out of Service Test mode (Service TestoTEST = OFF). START UP BY CHANGING PARAMETERS INDIVIDUALLY — Initial start-up is performed at the factory. To start up the VFD with by changing individual parameters, perform the following procedure: 1. Select MENU (SOFT KEY 2). The Main menu will be displayed. 2. Use the UP or DOWN keys to highlight PARAMETERS on the display screen and press ENTER (SOFT KEY 2). 3. Use the UP or DOWN keys to highlight the desired parameter group and press SEL (SOFT KEY 2). 4. Use the UP or DOWN keys to highlight the desired parameter and press EDIT (SOFT KEY 2). 5. Use the UP or DOWN keys to change the value of the parameter. 6. Press SAVE (SOFT KEY 2) to store the modified value. Press CANCEL (SOFTKEY 1) to keep the previous value. Any modifications that are not saved will not be changed. 7. Choose another parameter or press EXIT (SOFT KEY 1) to return to the listing of parameter groups. Continue until all the parameters have been configured and then press EXIT (SOFT KEY 1) to return to the main menu. NOTE: The current parameter value appears above the highlight parameter. To view the default parameter value, press the UP and DOWN keys simultaneously. To restore the default factory settings, select the application macro “HVAC Default.” Fig. B — VFD Keypad START UP WITH CARRIER ASSISTANT — Initial startup has been performed at the factory. If a VFD has been replaced, start up the VFD with the Carrier Assistant using the following procedure: NOTE: To change certain VFD parameters, the VFD must be in the OFF mode. To ensure the VFD is in the OFF mode prior to running the Carrier Assistant, it is recommended that you turn the drive OFF manually by pressing the OFF button on the VFD keypad. After completion of the Carrier Assistant, press the AUTO button on the VFD keypad to return to RUN mode. 1. Place the Comfortlink controls in Service Test mode (Service TestoTEST = ON). 2. With the VFD in the OFF mode, select MENU (SOFT KEY 2). The Main menu will be displayed. 3. Use the UP or DOWN keys to highlight ASSISTANTS on the display screen and press ENTER (SOFT KEY 2). 4. Use the UP or DOWN keys to highlight Carrier Assistant and press SEL (SOFT KEY 2). 5. The Carrier assistant will ask questions to determine the correct parameters for the VFD. a. The Carrier Assistant will ask “Select an App 1-3”: 1. Air Handler 2. Roof Top 3. Other Application b. Use the UP or DOWN keys to highlight Roof Top and press OK (SOFT KEY 2). c. The Carrier Assistant will ask “Is this a Hi E or Premium E motor?” : Hi E Premium E d. Use the UP or DOWN keys to highlight the correct motor efficiency and press OK (SOFT KEY 2). e. The Carrier Assistant will ask “Is this a Non-LEN VFD or LEN VFD?” : Non-LEN VFD LEN VFD f. Use the UP or DOWN keys to highlight LEN VFD and press OK (SOFT KEY 2). g. The Carrier Assistant will ask “Is this an IFM VFD or P.E. motor VFD?” : IFM VFD VFD Modes — The VFD has several different modes for configuring, operating, and diagnosing the VFD. The modes are: • Standard Display mode — shows drive status information and operates the drive • Parameters mode — edits parameter values individually • Start-up Assistant mode — guides the start up and configuration • Changed Parameters mode — shows all changed parameters • Drive Parameter Backup mode — stores or uploads the parameters • Clock Set mode — sets the time and date for the drive • I/O Settings mode — checks and edits the I/O settings 202