Download Agilent Technologies 81101A Programming instructions
Transcript
Using the Agilent 81101A The Mode/Trigger Screen For the second example, either the internal PLL or an external CLK-IN are used to source the periodboth cannot be triggered synchronously. Gated by: ARMING SOURCE PLL/CLK-IN NOT Synchronous to EXT INPUT DELAY = n * Period, 1 < n ≤ 2 (Gated by:) EXT INPUT or MAN Key Burst of 3 Period PERIOD SOURCE internal PLL. or CLK-IN OUTPUT Single Pulses OUTPUT Double Pulses TRIGGER OUT STROBE OUT 1st period last period 1st period last period External Width Mode In external width mode, the pulse width is determined by an external signal. You can choose between: MANKEY: Pressing the key generates a leading edge, releasing the key generates a trailing edge. EXT-IN: A rising edge at the EXT INPUT generates a leading edge, a falling edge generates a trailing edge. The threshold and impedance of the EXT INPUT can be set on the Trigger Level screen. The period, delay, and width of the output pulse are not programmable in this mode, because they are determined by the external signal. The TRIGGER OUT rises and falls parallel to the OUTPUT signal. 55