Divar - Easy | Installation Manual | Hardware setup
EN | 4-8
Signal name:
Pin no.
Description
Power Supply
Alarm_in_9
9
Alarm input 9
Alarm_in_10
10
Alarm input 10
Alarm_in_11
11
Alarm input 11
Power is supplied to the unit via the IEC-style socket. The unit has no on/off
switch for security reasons. This means that the unit is always powered as long as
the power cable is connected from the unit to a live power socket.
Alarm_in_12
12
Alarm input 12
Alarm_in_13
13
Alarm input 13
Specifications:
Alarm_in_14
14
Alarm input 14
Input Voltage:
100 - 240 Vac ±10%
Alarm_in_15
15
Alarm input 15
Current:
0.7A - 0.3A
Alarm_in_16
16
Alarm input 16
Input Frequency:
50/60 Hz
Relay1_A
17
Relay 1 output pole 1
Relay1_B
18
Relay 1 output pole 2
Relay2_A
19
Relay 2 output pole 1
Relay2_B
20
Relay 2 output pole 2
Relay3_A
21
Relay 3 output pole 1
Relay3_B
22
Relay 3 output pole 2
Relay4_A
23
Relay 4 output pole 1
Relay4_B
24
Relay 4 output pole 2
System Ground
25
Chassis Ground
Power supply socket
Signal
name:
Pin no.
Description
LIVE
1
AC live
NEUTRAL
2
AC neutral
PE
3
Protective Earth
N
E
L
Panel view
Bosch Security Systems