Download Sharp LC-20DV20U Specifications
Transcript
IMPORTANT SERVICE SAFETY INFORMATION Safety precautions to be followed during servicing: 1. Parts marked with an are critical parts for safety. Replace only with the one described in the parts list. 2. Before returning the DVD product to the customer, make the appropriate leakage current check or resistance measurements to ensure that exposed parts are properly insulated from the supply circuit. A leakage current check is recommended for this unit. Plug the AC line cord directly into a 120V 60Hz AC outlet (do not use an isolation transformer for this check). Use a leakage current tester (Fig. 1) or a metering system which complies with Underwriters Laboratories (UL 1492P). Measure for current from all exposed metal parts of the cabinet to a known earth ground: particularly, any exposed metal part having a return path to the chassis. Any current measured must not exceed 0.5mA. Any measurement not within the limits outlined above are indicative of a potential shock hazard and corrective action must be taken before returning the unit to the customer. PRODUCT UNDER TEST 2-Blade polarized type cord set Test all exposed metal surfaces 1.5K ohm 0.15 µF (Reading should not be above 0.5mA) Leakage Current Tester TEST PROBE Fig. 1 AC Leakage Test A1-2 KNOWN EARTH GROUND