Wiring Diagram - ADV8
BK
16 WIRE HARNESS
13
14
15
15
14
13
10
11
12
12
11
10
7
8
9
9
8
7
4
5
6
6
5
4
1
2
3
3
2
1
TO 115VAC/ 1
Ø /60 HZ POWER SUPPLY WITH
OVERCURRENT PROTECTION DEVICE
L
WARNING:
BR
24 VAC. HUM.
DISCONNECT POWER
BEFORE SERVICING.
WIRING TO UNIT
MUST BE PROPERLY
POLARIZED AND
GROUNDED.
BK
BK
RD
9
5
6
1
2
3
BR
BR
12
8
4
DOOR SWITCH
BR
11
7
10
N
SEE
NOTE 5
DISCONNECT
AUXILIARY
LIMIT CONTROL
BL
PU
DOOR
SWITCH
GND
WH
JUNCTION BOX
INDUCTOR COIL
90kBTU, 115 KBTU
MODELS ONLY
CIRCULATOR
BLOWER
WH
BK
INDOOR
AIR
CIRCULATOR
BLWR
YL
BK
BK
BL
CONTROL
PANEL
BK
115
VAC
24
VAC
JUNCTION BOX
LINE-N
WH
RD
SEE
NOTE 5
GND
BL
LINE H
LINE-N
EAC-H
EAC-N
ELECTRONIC
AIR CLEANER
INTEGRATED CONTROL MODULE
RD
OR
YL
WH
INTEGRATED CONTROL MODULE
GR
LINE-H
BK
IND HI
IND-N
ID
BLWR
IND LO
HUM-N
HUM-H
HUMIDIFIER
BK
IGN-H
TO 115 VAC/ 1/60HZ
POWER SUPPLY WITH
OVERCURRENT PROTECTION
DEVICE
IGN-N
HOT SURFACE
IGNITER
FP (3)
INDUCTOR COIL
ON SOME MODELS
FLAME SENSOR
BLOWER COMPARTMENT
XFMR-H
XFMR-N
115 VAC
BURNER COMPARTMENT
WH
WH
RD
BK
BR
BR
AUTO RESET
PRIMARY LIMIT
CONTROL
W1
HLO (11)
MANUAL RESET ROLLOUT
LIMIT CONTROL
YLO
HL1 (6)
W2
Y
G
YL
LOW FIRE
PRESSURE SWITCH
24V THERMOSTAT CONNECTIONS
BK
24
VAC.
HUM.
WH
OR
24 VAC
FUSE 3 A
YL
INDUCED
DRAFT
BLOWER
TH (5)
R
HI FIRE
PRESSURE SWITCH
RD
40 VA
TRANSFORMER
TO
MICRO
24V HUM.
PS1 (12)
C
NO
LOW FIRE
PRESSURE
SWITCH
PU
AUXILIARY LIMIT
CONTROL
BR
YL
C
BL
24V HUMIDIFIER
PRIMARY
LIMIT CONTROL
RD
MVL(7)
PM
MVH (1)
NO
C
HI
PS2 (2)
HIGH FIRE
PRESSURE SWITCH
MVC (8)
WH
BR
C
GAS
VALVE
GND (4)
BK
TR (9)
PU
2 STAGE
GAS VALVE
INTEGRATED CONTROL MODULE
++ - USE NEC CLASS 2 WIRE
ROLL OUT LIMITS CONTROL
FLAME
SENSOR
HOT
SURFACE
IGNITOR
0
STEADY ON = NORMAL OPERATION
1
1 FLASH
=
LINE VOLTAGE
2 FLASHES = LOW FIRE PRESSURE SWITCH STUCK CLOSED
3
3 FLASHES = LOW FIRE PRESSURE SWITCH STUCK OPEN
4
4 FLASHES = THERMAL PROTECTIVE DEVICE OPEN
FIELD WIRING
6
5 FLASHES = FLAME SENSED WITH GAS VALVE DE-ENERGIZED
HIGH VOLTAGE
7
7 FLASHES = LOW FLAME SENSE SIGNAL
8
8 FLASHES = CHECK IGNITER OR IMPROPER GROUNDING
9
9 FLASHES = HIGH FIRE PRESSURE SWITCH STUCK OPEN
C
CONTINUOUS FLASHES = 115 VOLT AC POWER REVERSED
COLOR CODES:
YL YELLOW
PK PINK
BR BROWN
SWITCH (TEMP.)
LOW VOLTAGE
IGNITER
SWITCH (PRESS.)
LOW VOLTAGE
NOTES:
OR ORANGE
WH WHITE
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.
BL BLUE
3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE
REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE
°C. USE COPPER CONDUCTORS ONLY.
RATING OF AT LEAST 105
GR GREEN
GY GRAY
BK BLACK
RD RED
OVERCURRENT
PROT. DEVICE
1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.
PU PURPLE
0140F00081P REV.0
IO-247C
FACTORY WIRING
SYSTEM LOCKOUT (RETRIES/RECYCLES EXCEEDED)
2
4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.
5. USE COPPER CONDUCTORS ONLY
34