Verification and Calibration - B Table B-4. Verification Test Record for Agilent Model 66309B/D Model Agilent___________ Report No.____________ Date_____________ Test Description Minimum Specification Recorded Results Maximum Specification Voltage Programming and Measurement −10 mV _____mV +10 mV Vfplo Vlo −5 mV _____mV Vlo +5 mV High Voltage Vhi 14.9825 V _______V 15.0175 V Front Panel measurement Vfphi Vhi −9.5 mV _______V Vhi +9.5 mV Outp 2 Low Voltage V2lo −40 mV _____mV +40 mV Outp 2 Front Panel measurement V2fplo V2lo −15 mV _____mV V2lo +15 mV Outp 2 High Voltage V2hi 11.936 V _______V 12.064 V Outp 2 Front Panel measurement V2fphi V2hi −39 mV _______V V2hi +39 mV Low Voltage Vlo Front Panel measurement Current Programming and Measurement (High Range) Low Current Ilo −2.3 mA _____mA 2.3 mA High Current Ihi 2.99717 A _______A 3.00283 A Front Panel measurement Ifphi Ihi −6.5 mA _______A Ihi +6.5 mA Outp 2 Low Current I2lo −4.5 mA _____mA 4.5 mA Outp 2 High Current I2hi 1.4925 A _______A 1.5075 A Outp 2 Front Panel measurement I2fphi I2hi −6 mA _______A I2hi +6 mA Current Measurement (Low Range) Low Current measurement Ilrlo Ilrlo −2.5 µA _____µA Ilrlo +2.5 µA High Current measurement Ilrhi Ilrhi −22.5 µA _____mA Ilrhi +22.5 µA Current Sink Measurement Low Current Sink measurement Isinklo Isinklo −22.5 µA _____mA Isinklo +22.5 µA High Current Sink measurement Isinkhi Isinkhi −5.1 mA _____A Isinkhi +5.1 mA DVM Voltage Measurement (Agilent 66309D only) Positive Voltage measurement Dvpos Dvpos −15 mV _____V Dvpos +15 mV Negative Voltage measurement Dvneg Dvneg −6.8 mV _____V Dvneg +6.8 mV 153