Download AE Remote PV Tie (RPT™) Accessory
Transcript
AE Remote PV Tie (RPT ) Accessory ™ Field-proven accessory that lowers home run conductor costs for commercial and utility-scale projects The greater the distance between the array and inverters, the higher the project cost and the higher the DC cable losses. You can reduce the levelized cost of energy (LCOE) with an Advanced Energy Remote PV Tie (RPT) by connecting the neutrals of the arrays in the field and eliminating expensive, long length and large diameter wires of the neutral DC home run legs and required conduit. The positive and negative hot wires connect the arrays to the AE inverter and the RPT puts the neutrals in series at the array. When installed with AE NX inverters, the RPT accessory reduces the distance of DC transmission current over conventional 600 VDC The AE RPT is backed with a complete 5-year warranty coverage ensuring there are no surprises during the warranty period. Plus, you have the peace of mind of being backed by AE's legendary service and support. distribution. Furthermore, having fewer jobs to perform Lower Operational LCOE during site construction helps ensure on-time startup. •Achieve high system efficiency with lower DC wiring losses Achieve Higher Efficiency •Reduce voltage drop in DC wiring During operation, conventional PV installations expend Reduce BoS Componenet of LCOE approximately 2% of energy production in resistive wiring losses •Cut neutral home run conductor costs alone. Using one or more RPT accessories in the center of the •Reduce installation labor array will cut DC losses. This enables the inverter to be placed in a position to reduce the AC wiring losses. The result is a higher total system efficiency that can create an opportunity to use fewer modules in your system. The robust, stainless steel, outdoor-ready design is used in a variety of environments from the high desert mountains to the Pacific tropics and reliably runs day in and day out with NEMA 3R construction. AE Solar Energy is a US based company. With the AE RPT™ accessory, you reduce BoS material costs and increase the potential for higher plant efficiency. Example PV System Installation with 500' (152 m) Between the PV Arrays and the AE NX Inverter * Wiring Costs Efficiency Gain (Due to Reduction in Resistive Wiring Losses, (I )R Loss) Conventional Inverter Installation Installation with AE RPT Accessory 500' of large diameter neutral wire = $12,000 500' of 16 AWG wire = $250 0% efficiency gain +2% additional efficiency or fewer panels required 2 Physical Dimensions 24" (H) x 24" (W) x 12" (D) 61 cm (H) x 61 cm (W) x 30.5 cm (D) Weight 90 lb (41.8 kg) unit weight Construction Stainless steel, outdoor-ready cabinet design Environmental NEMA 3R, Minimum mounting height 24" Significant savings can be realized by using the Remote PV Tie DC Input Power Connections 4 x 500 MCM per polarity (standard) 6 x 350 MCM + (3) 4/0 per polarity (optional) 16 x 2/0 per polarity (optional) M10 grounding studs (RPT) accessory with AE NX inverters and separable dual arrays. Max MPP Current 500 A @ 333 kW array and the inverter, reducing material and labor costs for the 750 A @ 500 kW installation. The savings depend on the distance between the array The RPT reduces the heavy gauge home run wiring between the and the inverter; the greater the distance, the greater the savings Max Distance Between RPT and AE NX Inverter 2000' (609.6 m) Control Wire 6 conductor, 600 V rated cable, Belden 1527A or equivalent recommended (customer supplied) that can be realized. Environmental Operating Ambient Temp Range -40 °F to 122 °F (-40 °C to 50 °C) Regulatory Agency Approvals / Regulatory Compliance NRTL certification to UL 1741-2010 by CSA International as an accessory to NX inverters *Specifications are subject to change without notice. Refer to user manual for detailed specification. 8 7 6 5 4 3 2 REV CHG# 1 ORIG CHK APP DESCRIPTION OF CHANGE + + + D + 15A TYP D EGC AE NX INVERTER - - COMMON GRND BUS 10' TAP TO INVERTER COMBINER + HOT POSITIVE ARRAY DC HOT LEG INPUT TO INVERTER REMOTE PV TIE TRANSFORMER COMMON GRND BUS C 3A MAX POSITIVE ARRAY NEUTRALS 1 3A 5A 3A MAX NEGATIVE ARRAY NEUTRALS 2 3A 4 0.05A FEEDBACK RPT1 C 5A 5 7 0.2A CONTACTOR COIL RPT1 CONTACTOR & COIL FOR RPT 8 REMOTE PV TIE CONTROL CABLE: 600V BELDEN 1527A COMMON GRND BUS B B NEGATIVE ARRAY DC HOT LEG INPUT TO INVERTER COMBINER - + HOT 10' TAP TO INVERTER + EGC + - 15A TYP - A A SIGNATURE ORIGINATOR AE Solar Energy • 115 Nicholson Lane • San Jose, CA 95134 www.advanced-energy.com/solarenergy 877.312.3832 • [email protected] • [email protected] Please see www.advanced-energy.com for worldwide contact information. 8 7 Advanced Energy is a trademark of Advanced Energy Industries, Inc. ® 6 5 4 DATE TITLE 3 LINE DIAGRAM: 8/30/11 BIPOLAR INVERTER © Advanced2/02/12 Energy Industries, Inc. 2012 ANASTASIOS HIONIS CHECKED ANASTASIOS HIONIS APPROVED ANASTASIOS HIONIS WITH RPT 2/02/12 All rights reserved.APrinted in U.S.A. 3L-500BP-RPT DRAWING NUMBER SCALE ENG-RPT-250-05 11/13 TITLE BLOCK REVISION 3 2 H NTS SHEET 1 REV. OF 1 B ADVANCED ENERGY PROPRIETARY INFORMATION 1 (R)