Download AE Remote PV Tie (RPT™) Accessory

Transcript
AE Remote PV Tie (RPT )
Accessory
™
Field-proven accessory that lowers
home run conductor costs for
commercial and utility-scale projects
The greater the distance between the array and inverters,
the higher the project cost and the higher the DC cable losses.
You can reduce the levelized cost of energy (LCOE) with an
Advanced Energy Remote PV Tie (RPT) by connecting the
neutrals of the arrays in the field and eliminating expensive,
long length and large diameter wires of the neutral DC home
run legs and required conduit. The positive and negative hot
wires connect the arrays to the AE inverter and the RPT puts
the neutrals in series at the array. When installed with AE
NX inverters, the RPT accessory reduces the distance of DC
transmission current over conventional 600 VDC
The AE RPT is backed with a complete 5-year warranty coverage
ensuring there are no surprises during the warranty period. Plus,
you have the peace of mind of being backed by AE's legendary
service and support.
distribution. Furthermore, having fewer jobs to perform
Lower Operational LCOE
during site construction helps ensure on-time startup.
•Achieve high system efficiency with lower DC wiring losses
Achieve Higher Efficiency
•Reduce voltage drop in DC wiring
During operation, conventional PV installations expend
Reduce BoS Componenet of LCOE
approximately 2% of energy production in resistive wiring losses
•Cut neutral home run conductor costs
alone. Using one or more RPT accessories in the center of the
•Reduce installation labor
array will cut DC losses. This enables the inverter to be placed
in a position to reduce the AC wiring losses. The result is a
higher total system efficiency that can create an opportunity
to use fewer modules in your system.
The robust, stainless steel, outdoor-ready design is used in a
variety of environments from the high desert mountains to the
Pacific tropics and reliably runs day in and day out with NEMA
3R construction.
AE Solar Energy is a US based company.
With the AE RPT™ accessory, you reduce BoS material costs and increase
the potential for higher plant efficiency.
Example PV System Installation with 500' (152 m)
Between the PV Arrays and the AE NX Inverter *
Wiring Costs
Efficiency Gain (Due to
Reduction in Resistive
Wiring Losses, (I )R Loss)
Conventional
Inverter Installation
Installation with
AE RPT Accessory
500' of large diameter
neutral wire = $12,000
500' of 16 AWG wire = $250
0% efficiency gain
+2% additional efficiency or
fewer panels required
2
Physical
Dimensions
24" (H) x 24" (W) x 12" (D)
61 cm (H) x 61 cm (W) x 30.5 cm (D)
Weight
90 lb (41.8 kg) unit weight
Construction
Stainless steel, outdoor-ready cabinet design
Environmental
NEMA 3R, Minimum mounting height 24"
Significant savings can be realized by using the Remote PV Tie
DC Input Power
Connections
4 x 500 MCM per polarity (standard)
6 x 350 MCM + (3) 4/0 per polarity (optional)
16 x 2/0 per polarity (optional)
M10 grounding studs
(RPT) accessory with AE NX inverters and separable dual arrays.
Max MPP Current
500 A @ 333 kW
array and the inverter, reducing material and labor costs for the
750 A @ 500 kW
installation. The savings depend on the distance between the array
The RPT reduces the heavy gauge home run wiring between the
and the inverter; the greater the distance, the greater the savings
Max Distance Between
RPT and AE NX Inverter
2000' (609.6 m)
Control Wire
6 conductor, 600 V rated cable, Belden 1527A or
equivalent recommended (customer supplied)
that can be realized.
Environmental
Operating Ambient
Temp Range
-40 °F to 122 °F (-40 °C to 50 °C)
Regulatory
Agency Approvals /
Regulatory Compliance
NRTL certification to UL 1741-2010 by CSA
International as an accessory to NX inverters
*Specifications are subject to change without notice. Refer to user manual for detailed specification.
8
7
6
5
4
3
2
REV CHG#
1
ORIG CHK APP
DESCRIPTION OF CHANGE
+
+
+
D
+
15A
TYP
D
EGC
AE NX INVERTER
-
-
COMMON GRND BUS
10' TAP TO
INVERTER
COMBINER
+ HOT
POSITIVE ARRAY DC
HOT LEG INPUT TO
INVERTER
REMOTE PV TIE
TRANSFORMER
COMMON
GRND BUS
C
3A MAX POSITIVE
ARRAY NEUTRALS
1
3A
5A
3A MAX NEGATIVE
ARRAY NEUTRALS
2
3A
4
0.05A FEEDBACK
RPT1
C
5A
5
7
0.2A CONTACTOR COIL
RPT1
CONTACTOR &
COIL FOR RPT
8
REMOTE PV TIE CONTROL
CABLE: 600V BELDEN 1527A
COMMON
GRND BUS
B
B
NEGATIVE ARRAY DC
HOT LEG INPUT TO
INVERTER
COMBINER
-
+
HOT
10' TAP TO
INVERTER
+
EGC
+
-
15A
TYP
-
A
A
SIGNATURE
ORIGINATOR
AE Solar Energy • 115 Nicholson Lane • San Jose, CA 95134
www.advanced-energy.com/solarenergy
877.312.3832 • [email protected][email protected]
Please see www.advanced-energy.com for worldwide contact information.
8
7
Advanced Energy is a trademark of Advanced Energy Industries, Inc.
®
6
5
4
DATE
TITLE
3 LINE DIAGRAM:
8/30/11
BIPOLAR INVERTER
© Advanced2/02/12
Energy Industries,
Inc. 2012
ANASTASIOS HIONIS
CHECKED
ANASTASIOS HIONIS
APPROVED
ANASTASIOS HIONIS
WITH RPT
2/02/12
All rights reserved.APrinted
in U.S.A.
3L-500BP-RPT
DRAWING NUMBER
SCALE
ENG-RPT-250-05 11/13
TITLE BLOCK REVISION
3
2
H
NTS
SHEET
1
REV.
OF
1
B
ADVANCED ENERGY
PROPRIETARY INFORMATION
1
(R)