Transcript
November 08, 2002 AlphaEclipse™ 3500 Series B Sign Installation Manual (pn 9711-6015B) Wired (RS485) computer-to-sign connection NOTE: Wired (RS485) connection can NOT be used with signs that are part of a Master/Slave network. 1. Open the sign according to “Appendix D: Opening and closing the sign” on page 35. 2. Connect the computer to the sign as shown below: NOTE: AlphaEclipse™ signs that are connected using RS485 must be properly terminated in order for the signs to operate. See “Appendix F: Termination” on page 45 for more information. NOTE: The Converter Box III cannot be located outdoors. Overview Computer running AlphaNET messaging software 10 feet max. up to 4000 feet RS232 RS485 RS232 cable (pn 10888634) Converter Box III (pn 10881111) Message 1 AlphaEclipse™ 3500 sign RS485 outdoor cable (pn 7122-0284) Internal sign connections Converter Box III (pn 1088-1111) To computer COM (RS232) port SERIAL PORT (on Controller board) SHEILD RED BLK + 5V GND RS232 RxD RS232 TxD SHIELD RS485 – RS485 + BLK RS485+ RED RS485- SHIELD SHIELD Serial I/O terminal block Figure 9: Wired RS485 computer-to-sign connection Wired (RS485) computer-to-sign connection 19