Download Printer Protocol Interpreter MGL™

Transcript
Packet Control Characters
Table 3. Configuration Packet
Synopsis
A,p,l,sp,sz,ss |
Example:
{I,A,0,0,0,1,0|}
Sets power-up
mode to online,
uses no batch
separator, uses
slash zero and
default symbol
set.
Description
Support
System Setup Field - A is the identifier for this
field, the other parameters are listed below.
Partial
p
Power-up
mode
0=Online (default)
1=Offline
1
Display
Language
0..12
Reference
Full
Ignored
The display
language must be
choosen using the
normal Printronix
menu to select a
language.
sp
Batch
Separators
0=No
1=Yes
2=Long
Full
Batch separators
will be added based
on customer
request.
sz
Slash Zero
0=Standard Zero
1=Slash Zero
Full
ss
Symbol
Set
0..24
Full
17