DT-DBC4S USER MANUAL V1.0 20120417 2 DBC4S 3 ON 1. Parts and Functions 1 2 3 1 DIP Impedance switch OFF ON POWER IN-USE Output BUS A B Output C D IN-USE:Status indicator,it will light up when receives signal. POWER:Working indicator,it will light up when plugs in power supply. Impedance Switch:Video match switch,the last DBC4S at the end of the bus should set ON to match the video impedance,the power indicator will turn to orange after setting. Bus:Input port,bus connection port. A,B,C,D:Output port,connect to indoor monitors or door stations. DIP :Used for current control when connected with different devices. 2. Unit Mounting DBC4S DIN Rail Mounting -1- 3. DIP Switch Setting The DIP switch in the back of the panel is used to adjust the terminal start-up current. Please refer to the followings for more detail informations about the DIP settings: DIP ON Bit State Descriptions ON,OFF,OFF The output port A,B,C,D connected with the device such as monitor(all DT model monitors),outdoor camera(DT59x),and DMR11 series without ID function model. OFF,ON,OFF The output port A,B,C,D connected with DMR11 series with ID function model. OFF,OFF,ON The output port A,B,C,D connected with DMR18 or DMR18/ID series door station. 1 23 ON 1 23 ON 1 23 Please note that DT59x(like DT591) and DMR18 can not be connected to the same DBC4S, If it happen,please use two DBC4S. The same situation as DMR11 and DMR18 model. 4. System Wiring with DBC4S Mulit Door Station Wiring: ID=00 ON ON ON 1 2 12 1# Camera ID=10 ON ON ON 1 2 ON 1 2 2# Camera ID=01 1 2 3# Camera ID=11 1 2 4# Camera ON 1 2 1 2 monitors L1 L2 PL S1+ S2+ S- L1 L2 PL S1+ S2+ S- L1 L2 PL S1+ S2+ S- DIP=on,off,off L1 L2 PL S1+ S2+ S- A B C D DBC4S DPS PS5 OFF 85~260VAC ON Impedance switch Note:the diagram uses DT591 as an example. -2- Mulit Monitors Wiring: ON monitor 1 2 3 4 5 6 monitor Impedance switch Code=14, DIP-6=on A B C D Code=15, DIP-6=on ON ON DIP=on,off,off monitor Code=12, DIP-6=on Code=13, DIP-6=on ON ON 1 2 3 4 5 6 1 2 3 4 5 6 monitor 1 2 3 4 5 6 monitor Code=2, DIP-6=on Impedance switch A B C D Code=3, DIP-6=on 1 2 3 4 5 6 Code=1, DIP-6=on DIP=on,off,off ON ON monitor OFF ON DBC4S 1 2 3 4 5 6 monitor OFF ON DBC4S ON 1 2 3 4 5 6 1 2 3 4 5 6 monitor Code=0, DIP-6=on DPS PS5 85~260AC ID=00 ON 1 2 -3- 5. Specification Power Supply : DC24V Working Temperature: -100C~+400C; Wiring: 2 wires (non-polarity); Dimension: 89(H)×70(W)×45(D)mm The design and specifications can be changed without notice to the user. Right to interpret and copyright of this manual are preserved. DT-ENG-DBC4S-V1 20120417