Download 120 Select Controller Programming Manual
Transcript
TEST RELAY Testing of Relays - This menu provides functions that allow the operator to test the operation of the individual relay lines 1 through 3. RELAY1 - Refrigeration Compressor. Dual Zone (software 67232 & 67234) only: If machine is located in a high ambient temperature environment, the condenser fan can be run all the time by turning off the Energy Saver Mode switch. This switch is located on the power panel. RELAY2 - Evaporator Fan RELAY3 - Heater Upon exit from the function, the state of the corresponding relay control line will revert to a state that is dependent on the controller's normal relay control algorithm. 1. STEP Press Service Button . DISPLAY 2. Press A , A , B . 3. Press A or C . 4. Press B . RELAY1 5. Press B . OFF * 6. Press B to test. ON * DIAGNOSE TEST VEND TEST RELAY 7. Press D or E to exit. RELAY1 8. Press C . RELAY2 9. Press B . OFF * 10. Press B to test. ON * Press D or E to exit. RELAY2 12 Press C . RELAY3 13. Press B . OFF * 14. Press B to test. ON * 15. Press D or E to exit. 16. Press Service Button . 11. RELAY3 (Sales Mode) WARNING: The operator should be aware that operations of the functions within this menu have direct control over whatever device(s) is/are connected to those lines. With some devices (such as compressors), there is the potential for damaging the device with frequent toggling of this line. 10 COMBO • SMVI • SM5700 • RFS • RSQF • SC100 • DUAL ZONE • P/N 4212619