Download Super-MMS - Home E-shop

Transcript
Super-MMS
Super
Modular
Engineering
Data Book
Multi
System
1
Foreword
Foreword
1
The engineering data book details all relevant data, charts
and drawings to enable you to get the best performance
from the Toshiba Super Modular Multi System for the
various applications.
The information is aimed to assist you by providing greater
detail of the system and the wider applications that the
system will cover.
It is recommended the use of the data book is used in
accordance with the following as references.
Design manual
: File No.A03-008
Installation manual : File No.A03-012
Service manual
: File No.A03-009
1
2
2
Contents
1
2
3
4
5
6
7
8
Foreword
Foreword .................................................................. 1
Contents ................................................................... 2
Introduction .............................................................. 5
System overview .........................................................9
Capacity compensation chart .....................................21
Piping requirements ...................................................29
Refrigerant cycle diagram ..........................................35
Sensible capacity table ..............................................45
Part load performance ...............................................71
10 Wiring guideline ........................................................85
11 Wiring diagram .......................................................... 95
9
A. Connection schematic (field wiring)
B. Inner circuit
12 Controls ...................................................................111
13 Fan characteristics ..................................................133
A. Static pressure
B. Air velocity profile (Air throw distance chart)
14 Sound characteristics (NC curve) .............................143
15 Dimensional drawing ...............................................163
A. Indoor units
B. Outdoor units
16 Specifications ..........................................................189
1. 50Hz models
2. 60Hz models
Appendix
High Wall Type (2 series)
1-Way Air Discharge Cassette Type (2 series)
Slim Duct Type
2
3
Introduction
3
4
3
Introduction
Foreword
,
World s Best Technology for Energy Saving System
Toshiba has attained the pinnacle of world technology in all aspects of efficiency, durability, and
comfort.
3
New large diameter propeller fan
(Flash wing fan)
High performance new bell mouth
(Smooth bell mouth)
Enlarged suction R
Reversed circular blade
Enlarged suction R allows smoother flow.
Enlarged fan diameter
The reversed circular form reduces the
interference of the flow between the blades,
and the backward vortex.
High efficiency DC fan motor
High output/
high efficiency
DC motor
High efficiency heat transfer pipe
R410A
+ Output 600W
+ Sine wave drive
Configuration of heat transfer pipe
AI dual inverter system
High speed calculation vector
control inverter
High efficiency DC twin rotary
compressor
,
World s first core technology: each module (singular outdoor unit) is installed with two (dual)
DC twin rotary compressors that work effectively with the highly efficient refrigerant R410A.
The system operates in the most optimum pattern for both energy saving and reliability.
-Installation Work:
Less Piping Material and Higher Efficiency
Cost Saving of Piping Material
Less piping work
Efficient Installation Work
Smaller piping diameters than ever before.
This is due to the all inverter type dual compressors,
Automatic configuration of outdoor unit.
Improved reliability with identical casing
Each outdoor unit (1 module)
is of the same size and
design. Therefore the basic
installation work will be
identical.
The unit has been designed
for your convenience, so it is
possible to fit the unit
comfortably into a standard
size elevator.
Automatic low-noise mode, only possible where
dual inverter type compressors are used.
Froom the weather data of the Japanese Mechanical and
Electrical Engineers building in the year 2000.
Tokyo (8:00 21:00) remote control temperature setting at 27
Outside noise(dB)
Time generated (Hours/year)
300
60
Time generated
Outdoor unit noise
250
55
Automatic
low noise mode
200
150
50
45
100
40
50
17
20
25
35
30
35
38
Outside temperature(oC )
* All our compressors are inverter type
Numbers used are expected numbers.
5
COP
3
High efficiency DC twin rotary compressor
Super-MMS (410A) *1
DC twin rotary compressors are most congenial with R410A and are used within
the outdoor units. (Conversion to all inverter type)
DC
fan motor
10HP System
3.80
20HP System
3.55
Leading the world with high efficiency and high COP
in both 1:1 system and VRF system.
*1
Super-MMS (8HP)
4.10
high-level
DC twin rotary compressor installed on all the outdoor
units for combined use!(Conversion to all inverter type)
Oil control is the key to the reliability.
Flexible to meet the sophisticated condition of
buildings or various customer requirements
Top
Top
Outlet
disk
compressor
unit
-Design Work:
High-speed
Calculation Vector
Control Inverter
Active oil control
Large space
The longest piping in the industry enabling
a flexible floor design.
motor
Bottom
1) Max Equivalent Length
175m
(Max Actual Length 150m)
roller
oil flow
Weight
67%
Volume
61%
Congenial with high
pressure refrigerant R410A
Force on the vertical shaft
(roller) is small.
Range of rotation
15-120rps
Compressor efficiency
See diagram on
the right
Oil discharge
1/40
(Compared with the conventional unit)
(ratio)
Comparison of compressor efficiencies
Total compressor efficiency (%)
(Compared with the conventional unit)
8 storey building can be
covered by one piping system.
4)Max from 1st Branch 65m
Compression structure by the rotation of the rollers inside
the fixed cylinder allows the easy supply of oil to the
swaying surface. The compressing rollers move in the
same direction as the rotary shaft. This creates a force in
the direction of compression even at high compression.
Thus high efficiency and reliability are attained.
3)Max Indoors Difference 30m
2)Height Difference - Upper Outdoor Unit
- Lower Outdoor Unit
50m
oil
TOSHIBA
1 Piping
System,
30m
(8 floors)
This difference is
the energy saving
Tw
i
Sc
20
40
ro
n
1)
ro
t
ar
Max
Equivalent
Length
y
ll
Super MMS
60
80
Max
Actual
Length
2)
3)
4)
Height Difference
Upper
Lower
Outdoor Unit Outdoor Unit
Max
Indoors
Difference
Max
from 1st
Branch
Total
Extension
30m
65m
300m 48units
175m 150m
50m
40m
Max
Connectable
Indoor Units
Super MMS enable flexible branching.
100
Rotation(rps)
You may change branching at installation sites.
(of the conventional unit)
Super MMS can quickly satisfy such
"Header branch after Y joint"
a requirement as addition of extra
according to original plan, but .... indoor unit(s)...
Unique
Therefore, all the compressor units can operate equally.
Y joint
technology
Y joint
Header branch
Header
branch
Y joint
Addition of extra
indoor unit
e.g. in case of a workload
of 2 compressor units;
Super MMS
ON
ON
OFF
ON
OFF
1
2
3
4
INV
Comp
Master/Follower
Part load COP
Compressor start
ON
INV
Comp
INV
Comp
INV
Comp
No Need
Higher COP
Equal start chance
As both heat exchangers on the
2 outdoor units are usable,
higher energy-saving
(higher efficiency) can be achieved.
High level, Energy saving VRF System
The sequence of the first
compressors start up, changes
whenever switching on.
Super MMS will offer the best solution for the
customers requirements as well as consideration of
ecology, with the unique technologies and advantages.
today
1
3
4
2
tomorrow
the day
after
tomorrow
2
4
3
1
1
2
3
4
Through avoiding concentration of the load at an individual unit,
prevention of failure and improvement of reliability are achieved.
6
Easy "Y joint branch after header
branch" solution in this example.
4
System overview
7
8
4
System overviewForeword
1. OUTLINE OF TOSHIBA SUPER MMS
(Super Modular Multi System)
Shortest route design by free branching
4
The Combination of line and header branching is highly flexible.
Following the shortest design route possible, thereby saving
on installation time and cost. Line/header branching after the
header branching is only available with TOSHIBA Super MMS.
Line branching
Outdoor unit
Branching joint
8F
Indoor unit
Header branching
Outdoor unit
7F
Branching
header
Indoor unit
Line + Header branching
Outdoor unit
Header
2F
Branching joint Indoor
unit
Line branching after header branching
Outdoor unit
Header
1F
Branching joint
Super
MMS
MMS Only
Only
Indoor unit
Header branching after header branching
Outdoor unit
Header
Super MMS
Only
Header
Indoor unit
9
Non-polarized control wiring
between the outdoor and indoor units
4
Outdoor unit
U1 U2
Indoor unit
U1 U2
U1 U2
U1 U2
Wiring diagnosis system
8F
Use the switches on the micro processor
P.C.B of the outdoor unit.
Detect wiring to the indoor unit b4 which
should not be in system A.
b4 is missing in the system B.
Piping
A
system
Outdoor
unit
a1
a2
Wiring
B
system
a3
a4
Indoor unit
Outdoor
unit
b1
b2
b3
b4
7F
Height difference between indoor
unit and indoor unit : 30m
2F
Height difference between indoor
unit and outdoor unit : 50m
Outdoor
unit
Allowable pipe length :
175m equivalent length
1st branching
section
From 1st branching to the
furthest indoor unit : 65m
1F
10
Compact design
The design of the modular TOSHIBA Super MMS outdoor unit allows for easy manoeuvering of the unit.
The unit will fit into any standard size lift.
The compactness of the unit allows for it to be installed into a limited space.
Largest system capacity
4
TOSHIBA Super MMS can be combined up to 48 HP (135kW) as one refrigerant system.
Energy saving
No. 1 COP in VRF industry. Compared with a conventional chiller fan coil system a large energy
saving can be achieved.
Advanced bus communication system
Wiring between indoor and outdoor units is a simple 2 core wire system.
Communication of addresses is also automatically configured.
A default test mode operation is available.
Self diagnostics system
Comprehensive troubleshooting codes allows for a timely identification of possible problems arising.
High lift design
Equivalent pipe length of 175m and vertical lift of 50m is possible with TOSHIBA Super MMS.
The maximum vertical lift between indoor units is 30m, this being the highest in the industry.
This allows for greater flexibility within the building design of the system.
Multiplied indoor units
Indoor units with different capacities and configurations can be combined up to a maximum of
135% of the outdoor units capacity.
A maximum of 48 indoor units can be combined with the 30 _ 48 HP outdoor units.
Intelligent control
TOSHIBA Super MMS intelligent controls and modulating valves deliver the required capacity,
according to the load variation from 50% to 100%.
The intelligent controls and modulating valves limit or increase the cooling capacity dynamically so
humidity and temperature are kept within the comfort zone.
Conforms to building control law
IAQ (Indoor Air Quality) is also achieved by combining various accessories required by the Building
Control Law.
Wide control applications
Artificial Intelligence Network system.
Central control and monitoring system available.
Weekly schedule operation through weekly timer.
Integration with Building Management System (BMS) is available.
11
2. SUMMARY OF SYSTEM EQUIPMENTS
Equipment
1. Outdoor units
Inverter unit
Corresponding HP
4
5 HP
6 HP
8 HP
10 HP
Appearance
12 HP
Heat pump MMY- MAP0501HT8 MAP0601HT8 MAP0801HT8 MAP1001H8 MAP1201HT8
Model
Heat pump MMY- MAP0501HT7 MAP0601HT7 MAP0801HT7 MAP1001HT7 MAP1201HT7
name
Cooling only MMY- MAP0501T8 MAP0601T8 MAP0801T8 MAP1001T8 MAP1201T8
Cooling capacity (kW)
14.0
16.0
22.4
28.0
33.5
Heating capacity (kW)
16.0
18.0
25.0
31.5
37.5
2. Outdoor units (Combination of outdoor units)
Corresponding HP
5 HP
6 HP
8 HP
10 HP
12 HP
MMY- MAP0501HT8 MAP0601HT8 MAP0801HT8 MAP1001HT8 MAP1201HT8
MMY- MAP0501HT7 MAP0601HT7 MAP0801HT7 MAP1001HT7 MAP1201HT7
MMY- MAP0501T8 MAP0601T8 MAP0801T8 MAP1001T8 MAP1201T8
Cooling capacity(kW)
14.0
16.0
22.4
28.0
33.5
Heating capacity(kW)
16.0
18.0
25.0
31.5
37.5
5 HP
6 HP
8 HP
10 HP
12 HP
Combined
outdoor units
Combined
Model
No. of connectable
indoor units
8
Corresponding HP
22 HP
MMY- AP2211HT8
MMY- AP2211HT7
MMYAP2211T8
Cooling capacity(kW)
61.5
Heating capacity(kW)
69.0
12 HP
10 HP
Combined
outdoor units
Combined
Model
No. of connectable
indoor units
16 HP
AP1601HT8
AP1601HT7
AP1601T8
45.0
50.0
8 HP
8 HP
18 HP
AP1801HT8
AP1801HT7
AP1801T8
50.4
56.5
10 HP
8 HP
20 HP
AP2001HT8
AP2001HT7
AP2001T8
56.0
63.0
10 HP
10 HP
22 HP
AP2201HT8
AP2201HT7
AP2201T8
61.5
69.0
8 HP
8 HP
6 HP
10
13
16
20
23
27
30
33
37
24 HP
AP2401HT8
AP2401HT7
AP2401T8
68.0
76.5
8 HP
8 HP
8 HP
24 HP
AP2411HT8
AP2411HT7
AP2411T8
68.0
76.5
12 HP
12 HP
26 HP
AP2601HT8
AP2601HT7
AP2601T8
73.0
81.5
10 HP
8 HP
8 HP
28 HP
AP2801HT8
AP2801HT7
AP2801T8
78.5
88.0
10 HP
10 HP
8 HP
30 HP
AP3001HT8
AP3001HT7
AP3001T8
84.0
95.0
10 HP
10 HP
10 HP
32 HP
AP3201HT8
AP3201HT7
AP3201T8
90.0
100.0
8 HP
8 HP
8 HP
8 HP
32 HP
AP3211HT8
AP3211HT7
AP3211T8
90.0
100.0
12 HP
10 HP
10 HP
34 HP
AP3401HT8
AP3401HT7
AP3401T8
96.0
108.0
10 HP
8 HP
8 HP
8 HP
34 HP
AP3411HT8
AP3411HT7
AP3411T8
96.0
108.0
12 HP
12 HP
10 HP
48
48
37
Corresponding HP
36 HP
MMY- AP3601HT8
Combined
MMY- AP3601HT7
Model
MMYAP3601T8
101.0
Cooling capacity(kW)
113.0
Heating capacity(kW)
10 HP
10 HP
Combined
outdoor units
8 HP
8 HP
No. of connectable
48
indoor units
14 HP
AP1401HT8
AP1401HT7
AP1401T8
38.4
43.0
8 HP
6 HP
40
40
43
47
48
48
48
36 HP
AP3611HT8
AP3611HT7
AP3611T8
101.0
113.0
12 HP
12 HP
12 HP
38 HP
AP3801HT8
AP3801HT7
AP3801T8
106.5
119.5
10 HP
10 HP
10 HP
8 HP
40 HP
AP4001HT8
AP4001HT7
AP4001T8
112.0
126.5
10 HP
10 HP
10 HP
10 HP
42 HP
AP4201HT8
AP4201HT7
AP4201T8
118.0
132.0
12 HP
10 HP
10 HP
10 HP
44 HP
AP4401HT8
AP4401HT7
AP4401T8
123.5
138.0
12 HP
12 HP
10 HP
10 HP
46 HP
AP4601HT8
AP4601HT7
AP4601T8
130.0
145.0
12 HP
12 HP
12 HP
10 HP
48 HP
AP4801HT8
AP4801HT7
AP4801T8
135.0
150.0
12 HP
12 HP
12 HP
12 HP
48
48
48
48
48
48
48
3. Branching joints and headers
Y-shape branching
joint (*3)
4-branching header
(*4)
8-branching header
(*4) (*5)
T-shape branching
joint
(For connection of
outdoor units)
12
*12
*3
*4
*5
*6
*
Model name
RBM-BY53E
RBM-BY103E
RBM-BY203E
RBM-BY303E
RBM-HY1043E
RBM-HY2043E
RBM-HY1083E
RBM-HY2083E
RBM-BT13E
Usage
Indoor unit capacity code (*1) : Total below 6.4
Indoor unit capacity code (*1) : Total 6.4 or more and below 14.2
(*2)
Indoor unit capacity code (*1) : Total 14.2 or more and below 25.2
(*2)
Indoor unit capacity code (*1) : Total 25.2 or more
(*2)
Indoor unit capacity code (*1) : Total below 14.2
Max.4
Indoor unit capacity code (*1) : Total 14.2 or more and below 25.2 branches
Indoor unit capacity code (*1) : Total below 14.2
Max.8
Indoor unit capacity code (*1) : Total 14.2 or more and below 25.2 branches
1 set of 3 types of T-shape joint pipes as described below:
The required quantity is arranged and they are combined at the site.
Connection piping
Corresponded dia. (mm)
o/9.5
Balance pipe
o/9.5 to o/22.2
Piping at liquid side
Piping at gas side
o/15.9 to o/41.3
Appearance
Qty
1
1
1
‘‘Capacity code’’ can be obtained. (Capacity code is not actual capacity)
If total capacity code value of indoor unit exceeds that of outdoor unit, apply capacity code of outdoor unit.
When using Y-shape branching joint for 1st branching, select according to the capacity code of the outdoor unit.
Max. capacity code of 6.0 in total can be connected.
If capacity code of outdoor unit is 26 or more, it is not used for 1st branching.
Model names for outdoor and indoor units described in this guide are shortened because of the space constraint.
Cooling Only model
50Hz
Super Modular Multi System Outdoor Unit :
List of Product and Combined Model Name
HP
No. of
(Capacity Model name combined
MMYcode)
units
Inverter
5 HP
MMY-
Used
Qty
5HP ( 5)
MAP0501T8
1
MAP0501T8
1
6HP ( 6)
MAP0601T8
1
8HP ( 8)
MAP0801T8
1
10HP (10) MAP1001T8
1
12HP (12) MAP1201T8
1
14HP (14)
AP1401T8
2
16HP (16)
AP1601T8
18HP (18)
AP1801T8
20HP (20)
AP2001T8
2
22HP (22)
AP2201T8
3
22HP (22)
AP2211T8
2
24HP (24)
AP2401T8
3
24HP (24)
AP2411T8
2
26HP (26)
AP2601T8
28HP (28)
30HP (30)
Inverter
6 HP
MMY-
Used
Qty
MAP0601T8
1
MAP0601T8
Inverter
8HP
MMY-
Used
Qty
MAP0801T8
1
MAP0801T8
1
2
MAP0801T8
2
2
MAP0801T8
1
MAP0601T8
1
Inverter
10HP
MMY-
Used
Qty
MAP1001T8
1
MAP1001T8
1
MAP1001T8
2
MAP1001T8
1
MAP0801T8
2
MAP0801T8
3
3
MAP0801T8
2
MAP1001T8
1
AP2801T8
3
MAP0801T8
1
MAP1001T8
2
AP3001T8
3
MAP1001T8
3
32HP (32)
AP3201T8
4
32HP (32)
AP3211T8
3
MAP1001T8
2
34HP (34)
AP3401T8
4
MAP1001T8
1
34HP (34)
AP3411T8
3
36HP (36)
AP3601T8
4
36HP (36)
AP3611T8
3
38HP (38)
AP3801T8
4
40HP (40)
AP4001T8
42HP (42)
AP4201T8
44HP (44)
1
Inverter
12HP
MMY-
Used
Qty
MAP1201T8
1
MAP1201T8
1
MAP1201T8
2
MAP1201T8
1
MAP1201T8
2
MAP1201T8
3
MAP0801T8
4
MAP0801T8
3
MAP1001T8
1
MAP0801T8
2
MAP1001T8
2
MAP0801T8
1
MAP1001T8
3
4
MAP1001T8
4
4
MAP1001T8
3
MAP1201T8
1
AP4401T8
4
MAP1001T8
2
MAP1201T8
2
46HP (46)
AP4601T8
4
MAP1001T8
1
MAP1201T8
3
48HP (48)
AP4801T8
4
MAP1201T8
4
4
1. Allocation standard of model name
MMY_ M
AP
T
8
Power supply specifications, 3O
/ 380_415 V, 50Hz ....... 8
T : Capacity variable unit
Development series No.
Capacity rank HP x 10
New refrigerant R410A
M : Single module unit, No mark : Combined Model name
Modular Multi
2. Range of combined capacity
No. of combined units: 1 to 4 units
Capacity of combined units: 14 HP (140 type) to 48 HP (480 type)
3. Rated conditions (Rated mode : Condition)
Cooling: Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB
13
Heat Pump model
4
50Hz
HP
No. of
(Capacity Model name combined
MMYcode)
units
Inverter
5 HP
MMY-
Used
Qty
5HP ( 5)
MAP0501HT8
1
MAP0501HT8
1
6HP ( 6)
MAP0601HT8
1
8HP ( 8)
MAP0801HT8
1
10HP (10) MAP1001HT8
1
12HP (12) MAP1201HT8
1
Inverter
6 HP
MMY-
Used
Qty
MAP0601HT8
1
MAP0601HT8
Inverter
8 HP
MMY-
Used
Qty
MAP0801HT8
1
MAP0801HT8
1
2
MAP0801HT8
2
2
MAP0801HT8
1
14HP (14)
AP1401HT8
2
16HP (16)
AP1601HT8
18HP (18)
AP1801HT8
20HP (20)
AP2001HT8
2
22HP (22)
AP2201HT8
3
22HP (22)
AP2211HT8
2
24HP (24)
AP2401HT8
3
24HP (24)
AP2411HT8
2
26HP (26)
AP2601HT8
28HP (28)
30HP (30)
MAP0601HT8
1
Inverter
10 HP
MMY-
Used
Qty
MAP1001HT8
1
MAP1001HT8
1
MAP1001HT8
2
MAP1001HT8
1
MAP0801HT8
2
MAP0801HT8
3
3
MAP0801HT8
2
MAP1001HT8
1
AP2801HT8
3
MAP0801HT8
1
MAP1001HT8
2
AP3001HT8
3
MAP1001HT8
3
32HP (32)
AP3201HT8
4
32HP (32)
AP3211HT8
3
34HP (34)
AP3401HT8
4
34HP (34)
AP3411HT8
3
36HP (36)
AP3601HT8
4
36HP (36)
AP3611HT8
3
38HP (38)
AP3801HT8
4
40HP (40)
AP4001HT8
42HP (42)
1
Inverter
12 HP
MMY-
Used
Qty
MAP1201HT8
1
MAP1201HT8
1
MAP1201HT8
2
MAP1201HT8
1
MAP1201HT8
2
MAP1201HT8
3
MAP0801HT8
4
MAP0801HT8
3
MAP1001HT8
1
MAP0801HT8
2
MAP1001HT8
2
MAP0801HT8
1
MAP1001HT8
3
4
MAP1001HT8
4
AP4201HT8
4
MAP1001HT8
3
MAP1201HT8
1
44HP (44)
AP4401HT8
4
MAP1001HT8
2
MAP1201HT8
2
46HP (46)
AP4601HT8
4
MAP1001HT8
1
MAP1201HT8
3
48HP (48)
AP4801HT8
4
MAP1201HT8
4
MAP1001HT8
2
MAP1001HT8
1
1. Allocation standard of model name
MMY_ M
AP
H
T
8
Power supply specifications, 3O
/ 380_415 V, 50Hz ....... 8
T : Capacity variable unit
H : Heat pump
Development series No.
Capacity rank HP x 10
New refrigerant R410A
M : Single module unit, No mark : Combined Model name
Modular Multi
2. Range of combined capacity
No. of combined units: 1 to 4 units
Capacity of combined units: 14 HP (140 type) to 48 HP (480 type)
3. Rated conditions (Rated mode : Condition)
Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB
Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB/6oC WB
14
Heat Pump model
60Hz
Super Modular Multi System Outdoor Unit :
List of Product and Combined Model Name
HP
No. of
(Capacity Model name combined
MMYcode)
units
Inverter
5 HP
MMY-
Used
Qty
5HP ( 5)
MAP0501HT7
1
MAP0501HT7
1
6HP ( 6)
MAP0601HT7
1
8HP ( 8)
MAP0801HT7
1
10HP (10) MAP1001HT7
1
12HP (12) MAP1201HT7
1
14HP (14)
AP1401HT7
2
16HP (16)
AP1601HT7
18HP (18)
AP1801HT7
20HP (20)
AP2001HT7
2
22HP (22)
AP2201HT7
3
22HP (22)
AP2211HT7
2
24HP (24)
AP2401HT7
3
24HP (24)
AP2411HT7
2
26HP (26)
AP2601HT7
28HP (28)
30HP (30)
Inverter
6 HP
MMY-
Used
Qty
MAP0601HT7
1
MAP0601HT7
Inverter
8 HP
MMY-
Used
Qty
MAP0801HT7
1
MAP0801HT7
1
2
MAP0801HT7
2
2
MAP0801HT7
1
MAP0601HT7
1
Inverter
10 HP
MMY-
Used
Qty
MAP1001HT7
1
MAP1001HT7
1
MAP1001HT7
2
MAP1001HT7
1
MAP0801HT7
2
MAP0801HT7
3
3
MAP0801HT7
2
MAP1001HT7
1
AP2801HT7
3
MAP0801HT7
1
MAP1001HT7
2
AP3001HT7
3
MAP1001HT7
3
32HP (32)
AP3201HT7
4
32HP (32)
AP3211HT7
3
34HP (34)
AP3401HT7
4
34HP (34)
AP3411HT7
3
36HP (36)
AP3601HT7
4
36HP (36)
AP3611HT7
3
38HP (38)
AP3801HT7
4
40HP (40)
AP4001HT7
42HP (42)
AP4201HT7
1
Inverter
12 HP
MMY-
Used
Qty
MAP1201HT7
1
MAP1201HT7
1
MAP1201HT7
2
MAP1201HT7
1
MAP1201HT7
2
MAP1201HT7
3
MAP0801HT7
4
MAP0801HT7
3
MAP1001HT7
1
MAP0801HT7
2
MAP1001HT7
2
MAP0801HT7
1
MAP1001HT7
3
4
MAP1001HT7
4
4
MAP1001HT7
3
MAP1201HT7
1
44HP (44)
AP4401HT7
4
MAP1001HT7
2
MAP1201HT7
2
46HP (46)
AP4601HT7
4
MAP1001HT7
1
MAP1201HT7
3
48HP (48)
AP4801HT7
4
MAP1201HT7
4
MAP1001HT7
2
MAP1001HT7
1
4
1. Allocation standard of model name
MMY_ M
AP
H
T
7
Power supply specifications, 3O
/ 380 V, 60Hz ....... 7
T : Capacity variable unit
H : Heat pump
Development series No.
Capacity rank HP x 10
New refrigerant R410A
M : Single module unit, No mark : Combined Model name
Modular Multi
2. Range of combined capacity
No. of combined units: 1 to 4 units
Capacity of combined units: 14 HP (140 type) to 48 HP (480 type)
3. Rated conditions (Rated mode : Condition)
Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB
Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB/6oC WB
15
4. Indoor unit
Type
4
4-way Air Discharge
Cassette Type
2-way Air Discharge
Cassette Type
1-way Air Discharge
Cassette Type
Slim Duct Type
Concealed Duct
Standard Type
Concealed Duct
High Static
Pressure Type
Under Ceilling Type
16-1
16
*1) China market only
Appearance
Model name
MMU-AP0091H
MMU-AP0121H
MMU-AP0151H
MMU-AP0181H
MMU-AP0241H
MMU-AP0271H
MMU-AP0301H
MMU-AP0361H
MMU-AP0481H
MMU-AP0561H
MMU-AP0071WH
MMU-AP0091WH
MMU-AP0121WH
MMU-AP0151WH
MMU-AP0181WH
MMU-AP0241WH
MMU-AP0271WH
MMU-AP0301WH
MMU-AP0481WH*1)
MMU-AP0071YH
MMU-AP0091YH
MMU-AP0121YH
MMU-AP0151SH
MMU-AP0181SH
MMU-AP0241SH
MMU-AP0152SH
MMU-AP0182SH
MMU-AP0242SH
MMD-AP0071SPH
MMD-AP0091SPH
MMD-AP0121SPH
MMD-AP0151SPH
MMD-AP0181SPH
MMD-AP0071SPH(SH)-C*1)
MMD-AP0091SPH(SH)-C*1)
MMD-AP0121SPH(SH)-C*1)
MMD-AP0151SPH(SH)-C*1)
MMD-AP0181SPH(SH)-C*1)
MMD-AP0071SPH-K*3)
MMD-AP0091SPH-K*3)
MMD-AP0121SPH-K*3)
MMD-AP0151SPH-K*3)
MMD-AP0181SPH-K*3)
MMD-AP0071BH
MMD-AP0091BH
MMD-AP0121BH
MMD-AP0151BH
MMD-AP0181BH
MMD-AP0241BH
MMD-AP0271BH
MMD-AP0301BH
MMD-AP0361BH
MMD-AP0481BH
MMD-AP0561BH
MMD-AP0181H
MMD-AP0241H
MMD-AP0271H
MMD-AP0361H
MMD-AP0481H
MMD-AP0721H
MMD-AP0961H
MMC-AP0151H
MMC-AP0181H
MMC-AP0241H
MMC-AP0271H
MMC-AP0361H
MMC-AP0481H
*2) European market only
*3) Korea market only
Cooling
Heating
Capacity rank Capacity code capacity (kW) capacity (kW)
009
012
015
018
024
027
030
036
048
056
007
009
012
015
018
024
027
030
048
007
009
012
015
018
024
015
018
024
007
009
012
015
018
007
009
012
015
018
007
009
012
015
018
007
009
012
015
018
024
027
030
036
048
056
018
024
027
036
048
072
096
015
018
024
027
036
048
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
1.00
1.25
1.70
2.00
2.50
3.00
3.20
4.00
5.00
6.00
0.8
1.00
1.25
1.70
2.00
2.50
3.00
3.20
5.00
0.80
1.00
1.25
1.70
2.00
2.50
1.70
2.00
2.50
0.80
1.00
1.25
1.70
2.00
0.80
1.00
1.25
1.70
2.00
0.80
1.00
1.25
1.70
2.00
0.80
1.00
1.25
1.70
2.00
2.50
3.00
3.20
4.00
5.00
6.00
2.00
2.50
3.00
4.00
5.00
8.00
10.00
1.70
2.00
2.50
3.00
4.00
5.00
2.8
3.6
4.5
5.6
7.1
8.0
9.0
11.2
14.0
16.0
2.2
2.8
3.6
4.5
5.6
7.1
8.0
9.0
14.0
2.2
2.8
3.6
4.5
5.6
7.1
4.5
5.6
7.1
2.2
2.8
3.6
4.5
5.6
2.2
2.8
3.6
4.5
5.6
2.2
2.8
3.6
4.5
5.6
2.2
2.8
3.6
4.5
5.6
7.1
8.0
9.0
11.2
14.0
16.0
5.6
7.1
8.0
11.2
14.0
22.4
28.0
4.5
5.6
7.1
8.0
11.2
14.0
3.2
4.0
5.0
6.3
8.0
9.0
10.0
12.5
16.0
18.0
2.5
3.2
4.0
5.0
6.3
8.0
9.0
10.0
16.0
2.5
3.2
4.0
5.0
6.3
8.0
5.0
6.3
8.0
2.5
3.2
4.0
5.0
6.3
2.5
3.2
4.0
5.0
6.3
2.5
3.2
4.0
5.0
6.3
2.5
3.2
4.0
5.0
6.3
8.0
9.0
10.0
12.5
16.0
18.0
6.3
8.0
9.0
10.0
16.0
25.0
31.5
5.0
6.3
8.0
9.0
12.5
16.0
4. Indoor unit
Type
High Wall Type
(1 series)
High Wall Type
(2 series)
Floor Standing
Cabinet Type
Floor Standind
Concealed Type
Floor Standind Type
*1) China market only
Appearance
Model name
MMK-AP0071H
MMK-AP0091H
MMK-AP0121H
MMK-AP0151H
MMK-AP0181H
MMK-AP0241H
MMK-AP0072H*2)
MMK-AP0092H*2)
MMK-AP0122H*2)
MML-AP0071H
MML-AP0091H
MML-AP0121H
MML-AP0151H
MML-AP0181H
MML-AP0241H
MML-AP0071H
MML-AP0091H
MML-AP0121H
MML-AP0151H
MML-AP0181H
MML-AP0241H
MMF-AP0151H
MMF-AP0181H
MMF-AP0241H
MMF-AP0271H
MMF-AP0361H
MMF-AP0481H
MMF-AP0561H
*2) European market only
*3) Korea market only
Cooling
Heating
Capacity rank Capacity code capacity (kW) capacity (kW)
007
009
012
015
018
024
007
009
012
007
009
012
015
018
024
007
009
012
015
018
024
015
018
024
027
036
048
056
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
type
0.80
1.00
1.25
1.70
2.00
2.50
0.80
1.00
1.25
0.80
1.00
1.25
1.70
2.00
2.50
0.80
1.00
1.25
1.70
2.00
2.50
1.70
2.00
2.50
3.00
4.00
5.00
6.00
2.2
2.8
3.6
4.5
5.6
7.1
2.2
2.8
3.6
2.2
2.8
3.6
4.5
5.6
7.1
2.2
2.8
3.6
4.5
5.6
7.1
4.5
5.6
7.1
8.0
11.2
14.0
16.0
2.5
3.2
4.0
5.0
6.3
8.0
2.5
3.2
4.0
2.5
3.2
4.0
5.0
6.3
8.0
2.5
3.2
4.0
5.0
6.3
8.0
5.0
6.3
8.0
9.0
10.0
16.0
18.0
4
16-2
17
5. Remote controller
Name Model
name
Appearance
Application
18
16-3
RBC-AMT21E/RBC-AMT31E
RBC-AS21E/RBC-AS21E2
TCB-AX21U(W)-E
TCB-AX21U(W)-E2
RBC-AX22CE
RBC-AX22CE2
TCB-AX21E
TCB-AX21E2
Wireless remote controller kit
Simple wired remote controller
4
Wired remote controller
Connected to indoor unit
Function
Start / Stop
Mode Change
Temperature setting
Change of air flow
Timer function
1 On or off timer operation, setting in 30
CODE No.
SET DATA
UNIT No.
SETTING TEST
R.C.
No.
UNIT
SET
Wired remote Wired remote controller
controller (In case of control by
2 remote controllers)
CL
Connected to indoor unit
TEST
SETTING
minute increments.
Automatic Off function.
2 Combined with the weekly timer, weekly
schedule operation can be operated.
Filter sign
Displays automatically maintenance time of
indoor filter.
Filter sign flashes.
Self-diagnosis function
Pressing‘‘CHECK’’ button displays cause of
fault on the check code.
Control by 2 remote controllers is available.
Two remote controllers can be connected to
one indoor unit. The indoor unit can be
separately operated from a different location.
Start / Stop
Temperature setting
Change of air flow
Check code display
ûC
ûF
Simple remote controller
Connected to indoor unit
Start / Stop
Mode change
Temperature setting
Change of air flow
Timer function
On or off timer operation, setting in 30 minute
increments.
Automatic Off function.
Control by 2 remote controllers is available.
Two wireless remote controllers can operate
one indoor unit. The indoor unit can be
separately operated from a different location.
Check code display
TCB-AX21U(W)-E
(for 4-way airdischarge cassette)
RBC-AX22CE
(for under ceiling)
TCB-AX21-E
(for other units except for the concealsed duct
high static pressure)
Name Model
name
Appearance
Application
Performance
Connected to central
remote controller or
wired remote controller
Weekly schedule operation
1 Setting different start / stop time for
each day of the week
2 ON / OFF can be set 3 times a day.
ON
OFF ON
RBC-EXW21E
RBC-EXW21E2
Weekly timer
8:00
OFF ON
4
OFF
12:00 13:00 18:00 19:00 21:00
3 ‘‘CHECK’’ ‘‘PROGRAM’’ ‘‘DAY’’
SuMoTuWeTh Fr Sa
Wired
remote controller
Weekly
timer
4 Two different schedules for a
week can be specified.
(Summer schedule and winter
schedule, etc.)
PROGRAM1
ERROR
PROGRAM2
button copying of setting easy.
PROGRAM3
WEEKLY TIMER
Outdoor unit
5 ‘‘CANCEL’’ ‘‘DAY’’ button enables
holiday setting.
6 If power supply fails, the setting
contents are stored in the memory
for 100 hours.
Weekly
timer
Central
remote controller
Connected to outdoor unit,
indoor unit
Header
Follower
Individual control up to 64 indoor units.
Individual control for max. 64 indoor
units divided into 4 zones.
Up to 16 indoor units
for each zone
Up to 16 outdoor header units are
connectable.
Outdoor unit
ZONE
ALL
ZONE
GROUP
TCB-SC642TLE
TCB-SC642TLE2
Central remote controller
4 type central control setting to
inhibit individual operation by remote
controller can be selected.
CODE
No.
1234
SET DATA
SETTING
R.C.
UNIT No.
TEST
No.
GROUP
SELECT
ZONE
CL
Central
remote controller
Setting for one of 1 to 4 zones is
available.
Can be used with other central control
devices (Up to 10 central control
devices with in one control circuit)
SET
Two selectable control modes
Central controller mode
Remote controller mode
Central
remote
controller
Indoor remote
controller
Setting of simultaneous ON/OFF 3
times for each day of the week
combined with a weekly timer.
1719
Name Model
name
Appearance
Application
Performance
Connected to outdoor unit,
indoor unit
Header
Follower
Individual control up to 16 indoor units.
Setting of simultaneous ON/OFF 3
times for each day of the week when
combined with a weekly timer.
Outdoor unit
TCB-CC163TLE
TCB-CC163TLE2
ON-OFF controller
Connected to 2 remote controllers is
possible.
ON-OFF
controller
Outdoor unit
ON-OFF
controller
Indoor
remote controller
18
20
5
Capacity compensation chart
19
Foreword
20
5
Foreword
Capacity compensation
chart
3. Cooling/heating capacity characteristics
1. Cooling capacity calculation method :
Required cooling capacity = Cooling capacity x Factor ( 1 , 2 , 3 , 4 , 5 *1) kW
Capacity correction value
1 Indoor air wet bulb temperature vs. capacity correction value
1.2
1.1
5
1.0
0.9
0.8
20
15
24
Indoor air wet bulb temp. ( )
Capacity correction value
2 Outdoor air dry bulb temperature vs.capacity correction value
1.2
1.1
1.0
0.9
-5
0
5
10
15
20
25
30
35
Outdoor air dry bulb temp. ( )
40 43
Capacity correction value
3 Air flow variation ratio of indoor unit vs. capacity correction (For concealed duct type only)
1.1
1.0
0.9
80
90
100
110
Air flow variation ratio (%)
120
*1 : Coefficient to use for the correction of the outdoor unit capacity when the total capacity of
the indoor units are not equal to the outdoor unit capacity.
21
5
Outdoor unit (5 to 44HP)
75
76
78
80
82
84
86
88
90
92
94
%100
50
40
30
20
10
0
-10
-20
-30
-40
98
9
Height of outdoor unit H (m)
Connecting pipe length and lift difference between indoor and outdoor units vs. capacity correction value
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170
Pipe length (Equivalent length) L (m)
Outdoor unit (46 to 48HP)
ho
l'o
L' is the longest one of
(l'o + l'a, l'o + l'b, l'o + l'c)
72
74
76
78
80
82
84
86
88
H = ho +
(Largest one of ha, hb, and hc)
90
50
40
30
20
10
0
-10
-20
-30
-40
100%
98
96
94
92
Height of outdoor unit H (m)
Outdoor unit
hc
hb
ha
l'a
l'b
l'c
A
B Indoor unit
C
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160
Pipe length (Equivalent length) L (m)
Correction of outdoor unit diversity
Correction (%)
120
100
80
60
40
20
0
20
40
60
80
100
120 135
Standard capacity ratio
Indoor units total capacity ratio (%)
*1 : Coefficient to use for the correction of the outdoor unit capacity when the total capacity of
the indoor units are not equal to the outdoor unit capacity.
22
Foreword
2. Heating capacity calculation method:
Required heating capacity = Heating capacity x Factor (
)kW
Capacity correction value
1 Indoor air dry bulb temperature vs. capacity correction value
1.2
1.1
1.0
5
0.9
0.8
15
20
24
Indoor air dry bulb temp. ( )
Capacity correction value
2 Outdoor air wet bulb temperature vs. capacity correction value
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
-15
-10
-5
0
5
10
15
Outdoor air wet bulb temp. ( )
Capacity correction value
3 Air flow variation ratio of indoor unit vs. capacity correction (For concealed duct type only)
1.1
1.0
0.9
80
90
100
110
Air flow variation ratio (%)
120
*1 : Coefficient to use for the correction of the outdoor unit capacity when the total capacity of
the indoor units are not equal to the outdoor unit capacity.
2
:
Refer
to item 3
*
23
Outdoor unit (5 to 48HP)
89
90
91
92
93
94
95
96
97
98
100%
50
40
30
20
10
0
-10
-20
-30
-40
9
5
Height of outdoor unit H (m)
4 Connecting pipe length and lift difference between indoor and outdoor units vs. capacity correction value
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170
Pipe length (Equivalent length) L (m)
Outdoor unit
ho
l'o
L' is the longest one of
(l'o + l'a, l'o + l'b, l'o + l'c)
H = ho +
(Largest one of ha, hb, and hc)
hc
hb
ha
l'a
l'b
l'c
A
B Indoor unit
C
5 Correction of outdoor unit diversity
120
Correction (%)
100
80
60
40
20
0
20
40
60
80
100
120 135
Standard capacity ratio
Indoor units total capacity ratio (%)
*1 : Coefficient to use for the correction of the outdoor unit capacity when the total capacity of
24
the indoor units are not equal to the outdoor unit capacity.
3. Capacity correction in case of frost on the outdoor heat exchanger when in heating
Correct the heating capacity when frost can be found on the outdoor heat exchanger.
Heating capacity = Capacity after correction of outdoor unit x Correction value of capacity resulted from frost
(Capacity after correction of outdoor unit : Heating capacity calculated in the above item 2.)
Capacity correction value
6 Capacity correction in case of frost on the outdoor heat exchanger
1.0
5
0.9
0.8
-15
-10
-5
0
5
10
Outdoor air wet bulb temp. ( )
4. Capacity calculation for each indoor unit
Capacity for each indoor unit
Required standard capacity of indoor unit
= Capacity after correction of outdoor unit x
Total value of standard indoor unit capacity
5. Operating temperature range
In heating time
In cooling time
20
Outdoor air wet bulb temp. ( )
35
30
25
Continuously
operable
range
20
15
Usable range
(in pull down)
Outdoor air dry bulb temp. ( )
40
10
5
0
15
10
5
Usable range
(in warming-up)
45
0
-5
Continuously
operable
range
-10
-15
-5
-10
10
-20
15
20
25
28
Indoor air wet bulb temp. ( )
30
5
10
15
20
25
30
Indoor air dry bulb temp. ( )
* The unit can be operated even if outdoor tem-
6. Rated conditions
Cooling : Indoor air temperature 27
Heating : Indoor air temperature 20
perature gets down to -20 . However, note that
the warranty covers only up to -15 because
operation beyond that temperature is out of
specification.
* When outdoor air temperature falls below
-15 , it may cause shortening of the products
lifetime.
DB/19.0 WB, Outdoor air temperature 35 DB
DB, Outdoor air temperature 7 DB/6 WB
25
26
6
Piping requirements
27
Foreword
28
6
Foreword
Piping requirements
1. Allowable length/height difference of refrigerant piping
D
Follower
unit 3
Height
difference
between
Outdoor unit
outdoor
units
H3 5m
A
Header
unit
B
Follower
unit 1
Lb
Header
unit
Follower
unit 2
Follower
unit 1
Follower
unit 2
Lc
Ld
LB
Main connecting piping between outdoor units
Length corresponded to farthest piping
between outdoor units LO 25 m
L1
Height
difference
between
outdoor
units
H1 50m
C
Follower
unit 2
Ex.2
Follower
unit 1
Connecting
piping of
outdoor unit
T-shape branching La
joint
LA
Main
piping
Ex.1
Header
unit
NOTE :
In case of connecting method Ex. 2, a large amount of
refrigerant and refrigerant oil may return to the head unit.
Therefore, set the T-shape joint so that oil does not enter directly.
Connecting piping of indoor unit
1st branching
section
6
Branching
header
Branching piping L2
a
L7
b
c
d
e
Indoor unit
L3
Equivalent length corresponded to farthest piping L
175 m
Equivalent length corresponded to farthest piping after 1st branching Li
f
g
Height difference
between indoor
units
H2 30m
L6
L5
L4
Y-joint
65 m
h
i
j
Indoor unit
System restrictions
Max. No. of combined outdoor units 4 units
Max. capacity of combined outdoor units 48 HP
Max. No. of connected indoor units 48 units
H2 <15
Max. capacity of combined
indoor units
H2 >15
135%
105%
Note 1) Combination of outdoor units : Header unit (1 unit) + Follower units (0 to 3 units).
Header unit is the outdoor unit nearest to the connected indoor units.
Note 2) Install the outdoor units in order of capacity.
(Header unit Follower unit 1 Follower unit 2 Follower unit 3)
Note 3) Refer to outdoor unit combination table.
Note 4) Piping to indoor units shall be perpendicular to piping to the header outdoor unit as <Ex.1>.
Do not connect piping to indoor units in the same direction of Header outdoor unit as <Ex.2>.
Allowable length and height difference of refrigerant piping
Allowable value
Total extension of pipe (Liquid pipe, real length)
Farthest piping length L (*)
Piping
length
300 m
Real length
150 m
Equivalent length
175 m
Piping section
LA + LB + La + Lb + Lc + Ld + L1 + L2 + L3 + L4+
L5 + L6 + L7 + a + b + c + d + e + f + g + h + i + j
LA + LB + Ld + L1 + L3 + L4 + L5 + L6 + j
Equivalent length of farthest piping from 1st branching Li (*)
65 m
L3 + L4 + L5 + L6 + j
Equivalent length of farthest piping between outdoor units LO (*)
25 m
LA + LB + Ld, (LA + Lb, LA + LB + Lc)
Max. equivalent length of main piping (***)
Max. equivalent length of outdoor unit connecting piping
85 m
L1
10 m
Ld, (La, Lb, Lc)
30 m
a, b, c, d, e, f, g, h, i, j
_
Max. real length of indoor unit connecting piping
Height between indoor
and outdoor units H1
Upper outdoor unit
Lower outdoor unit
Height
difference Height between indoor units H2
Height between outdoor units H3
50 m
40 m (**)
_
30 m
_
5m
_
* (D) is outdoor unit furthest from the 1st branch and ( j ) is the indoor unit furthest from the 1st branch.
** If the height difference (H2) between indoor units exceeds 3m, set below 30m.
*** If the maximum combined outdoor unit capacity is 46 HP or more, then the maximum equivalent
length is restricted to 70m.
29
2. Selection of refrigerant piping
Branching piping
Follower
unit 3
Follower
unit 2
Follower
unit 1 Header unit
6 Header branching pipe
4
Indoor unit connecting piping
Outdoor
unit
5
4
5
5
5
5
5
5
2 Balance pipe
Indoor unit
6 T-shape
1 Outdoor unit
1
connecting
piping
1
branching joint
1
3 Main piping
2
2
branching
joint
4
4
4
5
5
5
4
Main connecting
piping between
outdoor units
6
6 Y-shape
1st branching
Indoor unit
section
connecting piping
Indoor unit
1 Pipe size of outdoor unit (Table 1)
Model name
5 Piping of indoor unit (Table 5)
Gas side
Liquid side
MAP0501T8
MAP0501HT8
MAP0501HT7
O
/ 15.9
O
/ 9.5
MAP0601T8
MAP0601HT8
MAP0601HT7
O
/ 19.1
O
/ 9.5
MAP0801T8
MAP0801HT8
MAP0801HT7
O
/ 22.2
O
/ 12.7
MAP1001T8
MAP1001HT8
MAP1001HT7
O
/ 22.2
MAP1201T8
MAP1201HT8
MAP1201HT7
O
/ 28.6
MMY-
Gas side
Liquid side
Real length 15m or less
O
/ 9.5
O
/ 6.4
Real length exceeds 15m
O
/ 12.7
O
/ 6.4
015 type to 018 type
O
/ 12.7
O
/ 6.4
O
/ 12.7
024 type to 056 type
O
/ 15.9
O
/ 9.5
O
/ 12.7
072 type to 096 type
O
/ 22.2
O
/ 12.7
2 Connecting pipe size between outdoor units (Table 2)
Total capacity code of outdoor
units at downstream side
Gas side
Liquid side
14 to below 22
O
/ 28.6
O
/ 15.9
22 to below 26
O
/ 34.9
O
/ 15.9
26 to below 36
O
/ 34.9
O
/ 19.1
36 or more
O
/ 41.3
O
/ 22.2
O
/ 9.5
Gas side
Liquid side
Below 6
O
/ 15.9
O
/ 9.5
6 to below 8
O
/ 19.1
O
/ 9.5
8 to below 12
O
/ 22.2
O
/ 12.7
12 to below 14
O
/ 28.6
O
/ 12.7
14 to below 22
O
/ 28.6
O
/ 15.9
22 to below 26
O
/ 34.9
O
/ 15.9
26 to below 36
O
/ 34.9
O
/ 19.1
36 to below 46
O
/ 41.3
O
/ 22.2
*5
Total capacity code of indoor unit *1
Y-shape
branching joint
2
*
For 4
branching
* Branching
header
3
*6
For 8
branching
T-shape
branching joint
(For
connecting
outdoor unit)
4 Pipe size between branching sections (Table 4)
RBM-BY53E
6.4 to below 14.2
RBM-BY103E
14.2 to below 25.2
RBM-BY203E
25.2 or more
RBM-BY303E
Below 14.2
RBM-HY1043E
14.2 to below 25.2
RBM-HY2043E
Below 14.2
RBM-HY1083E
14.2 to below 25.2
RBM-HY2083E
1 set of 3 types of T-shape joint pipes as
described below:
The required quantity is arranged and
combined
at the site.
Balance pipe
(Corresponded difference O/ 9.52) 1
Piping at liquid side
(Corresponded difference O/ 9.5 to O/ 22.1) 1
RBM-BT13E
Piping at gas side
(Corresponded difference O/ 15.9 to O/ 41.3) 1
O
/ 22.2
Determine thickness of the main pipe according to capacity of the outdoor
units.
7 Minimum wall thickness for R410A application
(Table 7)
Total capacity code of indoor units at
downstream side *1
Gas side
Liquid side
OD (mm)
Minimum wall thickness (mm)
2.8 or less
O
/ 12.7
O
/ 9.5
OK
OK
1/4''
6.35
0.80
2.8 to below 6.4
O
/ 15.9
O
/ 9.5
OK
OK
3/8''
9.52
0.80
6.4 to below 12.2
O
/ 22.2
O
/ 12.7
OK
OK
1/2''
12.70
0.80
12.2 to below 20.2
O
/ 28.6
O
/ 15.9
OK
OK
5/8''
15.88
1.00
20.2 to below 25.2
O
/ 34.9
O
/ 15.9
NG*4
OK
3/4''
19.05
1.00
25.2 to below 35.2
O
/ 34.9
O
/ 19.1
NG*4
OK
7/8''
22.20
1.00
35.2 or more
O
/ 41.3
O
/ 22.2
NG*4
OK
1.1/8''
28.58
1.00
NG*4
OK
1.3/8''
34.92
1.10
NG*4
OK
1.5/8''
41.28
1.25
If the total capacity code value of indoor units exceeds that of the outdoor
units, apply the capacity code of outdoor units.
*1
*2
*3
*4
*5
*6
30
Model name
Below 6.4
Total capacity code of all outdoor units *1
O
/ 41.3
6 Selection of branching section (Table 6)
Balance pipe
3 Size of main pipe (Table 3)
46 or more
Capacity rank
007 type to
012 type
Soft Half hard or hard OD (Inch)
Code is determined according to the capacity rank.
When using a Y-shape branching joint for the 1st branch, select according to capacity code of the outdoor unit.
For 1 line after branching header indoor units with a maximum capacity code of 6.0 in total can be connected.
If the pipe size is O
/ 19.0 or more, use a suitable material as detailed in the installation manual.
The maximum equivalent length of the main pipe should be 70m.
When the first branch is a header with the outdoor total capacity codes of 12 to 26, apply the model RBMHY2043E(4-branch) or RBM-HY2083E(8-branch) regardless of the total capacity codes of the down-stream
indoor units.
Foreword
3. Charging requirement with additional refrigerant
After the system has been vacuumed, replace the vacuum pump with a refrigerant cylinder and charge the
system with additional refrigerant.
Calculating the amount of additional refrigerant required
R410A
Refrigerant in the system when shipped from the factory
Refrigerant amount
charged in factory
5HP
6HP
8HP
10HP
12HP
Heat pump model
8.5kg
8.5kg
12.5kg
12.5kg
12.5kg
Cooling only model
8.0kg
8.0kg
11.0kg
11.0kg
11.0kg
When the system is charged with refrigerant at the factory, the amount of refrigerant needed for the pipes at the
site is not included. Therefore, calculate the additional amount needed and add the required amount to the system.
(Calculation)
6
Additional refrigerant charge amount is calculated based on the size of liquid pipe at site and its real length.
Additional refrigerant charge amount at site =
Additional refrigerant charge amount +
Real length of liquid pipe X
Compensation by system HP (Table 2)
per liquid pipe 1m (Table 1)
Example : Additional charge amount R (kg) = (L1 x 0.025kg/m) + (L2 x 0.055kg/m) + (L3 x 0.105kg/m) + (3.0kg)
L1 : Real total length of liquid pipe 6.4 (m)
L2 : Real total length of liquid pipe 9.5 (m)
L3 : Real total length of liquid pipe 12.7 (m)
Table 7-1
Pipe dia. at liquid side
Additional refrigerant amount/1m
o/ 6.4
o/ 9.5
o/ 12.7
o/ 15.9
o/ 19.0
o/ 22.2
0.025kg
0.055kg
0.105kg
0.160kg
0.250kg
0.350kg
Table 7-2
Combined
horse power
(HP)
Outdoor combination
(HP)
Compensation
by System HP
(kg)
Combined
horse power
(HP)
Outdoor combination
(HP)
Compensation
by System HP
(kg)
5
5
0.0
28
10
10
8
-2.0
6
6
0.0
30
10
10
10
0.0
8
8
1.5
12
10
10
1.0
10
10
2.5
8
8
8
12
12
3.5
12
12
10
14
8
6
0.0
10
8
8
16
8
8
0.0
12
12
12
18
10
8
0.0
10
10
8
8
-6.0
20
10
10
3.0
38
10
10
10
8
-6.0
12
10
5.0
40
10
10
10
10
-5.0
8
8
0.0
42
12
10
10
10
-4.0
12
12
7.0
44
12
12
10
10
-2.0
8
8
8
-4.0
46
12
12
12
10
0.0
10
8
8
-4.0
48
12
12
12
12
2.0
22
24
26
6
32
34
36
8
-6.0
3.0
8
-6.0
4.0
31
32
7
Refrigerant cycle diagram
33
Foreword
34
7
Refrigerant cycleForeword
diagram
1. Inverter Unit (5, 6, 8, 10, 12HP)
Model: MMY-MAP0501HT, MAP0601HT, MAP0801HT, MAP1001HT, MAP1201HT
(8,10,12HP)
Propeller fan
(PMV1)
(PMV2)
M
Sensor
(TE1)
Fan motor
(Right side)
Sensor
(TO)
Air heat exchanger at outdoor side
Strainer
(Left side)
Pulse motor
valve (PMV)
Air heat exchanger at outdoor side
(5,6HP)
7
(PMV1)
Strainer
4-Way valve
Solenoid valve (SV5)
Check valve
Sensor (TS1)
Solenoid valve
(SV2)
Capillary tube
High-pressure
sensor
Check joint
Sensor
(TL)
Low-pressure
sensor
Check joint
Capillary tube
Oil
Solenoid valve
Strainer
separator
(SV3D)
Capillary tube
Strainer
Check
valve
Solenoid valve
(SV41)
Check
valve
High-pressure
switch
High-pressure
switch
Check
joint
Capillary
tube
Compressor 1
(Inverter)
Sensor
(TD1)
Solenoid
valve
(SV3C)
Sensor
(TK3)
Strainer
Check
valve
Capillary tube
Sensor
(TK1)
Solenoid
valve
(SV3E)
Strainer
Check
valve
Oil tank
Sensor
(TK4)
Capillary tube
Strainer
Strainer
Accumulator
Sensor
(TD2)
Capillary tube
Sensor
(TK2)
Capillary tube
Strainer
Solenoid valve
(SV42)
Compressor 2
(Inverter)
Liquid
tank
Check
valve
Solenoid
valve
(SV3A)
Solenoid
valve
(SV3B)
Check
valve
Balance Liquid
pipe
side
servise servise
valve
valve
Gas
side
servise
valve
35
2. Explanation of Functional Parts
Functional part name
Solenoid valve
1.SV3A
2.SV3B
(Connector CN313: Blue)
1) Returns oil in the balance pipe to the compressor.
3.SV3C
(Connector CN314: Black)
1) Pressurizes oil reserved in the oil tank during operation.
4.SV3D
(Connector CN323: White)
1) Reserves oil in the oil separator during OFF time, and supplies oil during operation.
5.SV3E
(Connector CN323: White)
1) Turns on during operation and balances oil between the compressors.
6.SV2
(Hot gas bypass) (Connector CN312: White)
1) Low pressure release function
2) High pressure release function
3) Gas balance during off status
7.SV4(n)
(Start compensation valve of compressor) (Connector CN311: Blue)
1) For gas balance start
2) High pressure release function
3) Low pressure release function
8.SV5
(Connector CN310: White) (for Heating model only)
1) Preventive function for high-pressure rising in heating operation
7
4-way valve
(Connector CN317: Blue)
1) Cooling/heating exchange
2) Reverse defrost
Pulse motor valve PMV1,2
(Connector CN300, 301: White)
1) Super heat control function in heating operation
2) Liquid line shut-down function while follower unit stops
3) Under-cool adjustment function in cooling operation
Oil separator
Temp. sensor
1) Prevention for rapid decreasing of oil (Decreases oil flowing to the cycle)
2) Reserve function of surplus oil
1. TD1
TD2
(TD1: Connector, CN502: White, TD2: Connector, CN503: Pink)
1) Protection of compressor discharge temp. Used for release
2. TS1
(Connector CN504: White)
1) Controls super heat in heating operation
3. TE1
(Connector CN505: Green)
1) Controls defrost in heating operation
2) Controls outdoor fan in heating operation
4. TK1, TK2,
TK3, TK4
Pressure sensor
Heater
Balance pipe
36
Functional outline
(Connector CN324: Red)
1) Collects oil in the oil tank during OFF time.
2) Supplies oil in the oil tank during ON time.
Connector CN514: Black, TK2 Connector CN515: Green,
( TK1
TK3 Connector CN516: Red, TK4 Connector CN523: Yellow )
1) Judges oil level of the compressor
5. TL
(Connector CN521: White)
1) Detects under cool in cooling operation
6. TO
(Connector CN507: Yellow)
1) Detects outside temperature
1.High pressure
sensor
(Connector CN501: Red)
1) Detects high pressure and controls compressor capacity
2) Detects high pressure in cooling operation, and controls the fan in low ambient
cooling operation
2. Low pressure
sensor
(Connector CN500: White)
1) Detects low pressure in cooling operation and controls compressor capacity
2) Detects low pressure in heating operation, and controls the super heat
Compressor case
heater
(Compressor 1 Connector CN316: White, Compressor 2 Connector CN315: Blue)
1) Prevents liquid accumulation to compressor
Accumulator case
heater
(Connector CN321: Red)
1) Prevents liquid accumulation to accumulator
1) Oil balancing in each outdoor unit
Foreword
3. Indoor Unit
Liquid side Gas side
Strainer
Capillary tube
Air heat exchanger
at indoor side
7
Pulse Motor
Valve (PMV)
Strainer
Sensor
(TCJ)
Sensor
(TC2)
Fan
Sensor
(TC1)
Sensor
(TA)
M
Fan motor
(NOTE) MMU-AP0071YH to AP0121YH type air conditioners do not have a TC2 sensor.
Functional part name
Pulse Motor Valve PMV
Temp. sensor
Functional outline
(Connector CN082 (6P): Blue)
1)Controls super heat in cooling operation
2)Controls under cool in heating operation
3)Recovers refrigerant oil in cooling operation
4)Recovers refrigerant oil in heating operation
1. TA
(Connector CN104 (2P): Yellow)
1)Detects indoor suction temperature
2. TC1
(Connector CN100 (3P): Brown)
1)Controls PMV super heat in cooling operation
3. TC2
(Connector CN101 (2P): Black)
1)Controls PMV under cool in heating operation
4. TCJ
(Connector CN102 (2P): Red)
1)Controls PMV super heat in cooling operation
2) MMU-AP0071 to AP0121YH only
Controls PMV under cool in heating operation
37
COMBINED REFRIGERANT PIPES SYSTEMATIC DRAWING
1. Normal Operation (COOL Mode / DEFROST Mode)
Header unit
(MMY-MAP1001H)
Follower unit
(MMY-MAP1001H)
FM
FM
TE1
TE1
TO
PMV1
PMV2
TO
4-Way valve
SV5
PMV1
PMV2
4-Way valve
SV5
TS1
TL
TS1
SV2
Pd sensor
SV2
Pd sensor
TL
Ps sensor
Ps sensor
OS
OS
SV3D
Liquid
tank
SV41
SV42
HP
HP
SV3C
TK1
SV3E
HP
TK2
TK3
TK1
Oil tank
TK4
SV3C
TD1
Compressor
1
TK3
SV42
HP
Accumulator
TD2
Compressor
2
Compressor
1
TD1
SV41
SV3E
SV3A
Accumulator
TD2
Compressor
2
7
SV3D
Liquid
tank
TK2
Oil tank
TK4
SV3A
SV3B
SV3B
Balance pipe
Liquid pipe
Gas pipe
Gas pipe
Liquid pipe
Strainer
Strainer
Strainer
PMV
TC2
TCJ
Strainer
Strainer
PMV
TC1
TC2
TCJ
Strainer
Strainer
PMV
TC1
TC2
TCJ
Strainer
PMV
TC1
TC2
TCJ
TC1
Indoor unit
High-pressure gas or condensate liquid refrigerant
Evaporative gas refrigerant (Low-pressure gas)
NOTE
An outdoor unit which is connected with indoor/outdoor communication lines is
referred to as the ‘‘Header unit’’, and the other unit is called the ‘‘Follower unit’’.
38
(Example: 20HP system)
2. Normal Operation (HEAT Mode)
Header unit
(MMY-MAP1001H)
Follower unit
(MMY-MAP1001H)
FM
FM
TE1
TE1
TO
PMV1
PMV2
TO
4-Way valve
SV5
PMV1
PMV2
4-Way valve
SV5
TS1
TL
TS1
SV2
Pd sensor
SV2
Pd sensor
TL
Ps sensor
Ps sensor
OS
OS
SV3D
SV3D
Liquid
tank
Liquid
tank
SV42
HP
HP
SV3C
TK1
SV3E
HP
TK2
TK3
TK1
Oil tank
TK4
SV3C
TD1
Compressor
1
TK3
SV3E
SV3A
7
SV42
HP
Accumulator
TD2
Compressor
2
Compressor
1
TD1
SV41
Accumulator
TD2
Compressor
2
SV41
TK2
Oil tank
TK4
SV3A
SV3B
SV3B
Balance pipe
Liquid pipe
Gas pipe
Gas pipe
Liquid pipe
Strainer
Strainer
Strainer
PMV
TC2
TCJ
Strainer
Strainer
PMV
TC1
TC2
TCJ
Strainer
Strainer
PMV
TC1
TC2
TCJ
Strainer
PMV
TC1
TC2
TCJ
TC1
Indoor unit
High-pressure gas or condensate liquid refrigerant
Evaporative gas refrigerant (Low-pressure gas)
NOTE
An outdoor unit which is connected with indoor/outdoor communication lines is
referred to as the ‘‘Header unit’’, and the other unit is called the ‘‘Follower unit’’.
(Example: 20HP system)
39
3. Backup Operation
(Cooling Operation when Header Outdoor unit failure)
Header unit
(MMY-MAP1001H)
Follower unit
(MMY-MAP1001H)
Unit set temporarily
to header unit during
emergent operation.
Failure
FM
FM
TE1
TE1
TO
TO
*1
PMV1
PMV2
4-Way valve
SV5
PMV1
PMV2
4-Way valve
SV5
TS1
TL
TS1
SV2
Pd sensor
SV2
Pd sensor
TL
Ps sensor
Ps sensor
OS
OS
SV3D
Liquid
tank
SV41
SV42
HP
HP
SV3C
TK1
SV3E
HP
TK2
TK3
TK1
Oil tank
TK4
SV3C
TD1
Compressor
1
TK3
SV42
HP
Accumulator
TD2
Compressor
2
Compressor
1
TD1
SV41
SV3E
SV3A
TK2
Oil tank
TK4
SV3A
SV3B
*3
*2
Accumulator
TD2
Compressor
2
7
SV3D
Liquid
tank
SV3B
Balance pipe
*1 When liquid leaks from PMV, packed valve
Liquid pipe
at liquid side = Close fully
Gas pipe
*2 Gas pipe service valve = Close fully
*3 Balance pipe packed valve = Open fully
Gas pipe
Liquid pipe
Strainer
Strainer
Strainer
PMV
TC2
TCJ
Strainer
Strainer
PMV
TC1
TC2
TCJ
Strainer
Strainer
PMV
TC1
TC2
TCJ
Strainer
PMV
TC1
TC2
TCJ
TC1
Indoor unit
High-pressure gas or condensate liquid refrigerant
Evaporative gas refrigerant (Low-pressure gas)
NOTE
An outdoor unit which is connected with indoor/outdoor communication lines is
referred to as the ‘‘Header unit’’, and the other unit is called the ‘‘Follower unit’’.
40
(Example: 20HP system)
4. Emergent Operation
(Heating Operation when Header Outdoor unit failure)
Header unit
(MMY-MAP1001H)
Failure
Follower unit
(MMY-MAP1001H)
Unit set temporarily
to header unit during
emergent operation.
FM
FM
TE1
TE1
TO
TO
*1
PMV1
PMV2
4-Way valve
SV5
PMV1
PMV2
4-Way valve
SV5
TS1
TS1
SV2
Pd sensor
TL
SV2
Pd sensor
TL
Ps sensor
Ps sensor
OS
OS
SV3D
SV3D
Liquid
tank
Liquid
tank
SV42
HP
HP
SV3C
TK1
SV3E
HP
TK2
TK3
TK1
Oil tank
TK4
SV3C
TD1
Compressor
1
TK3
SV3E
SV3A
*2
Accumulator
TD2
TK2
Oil tank
TK4
SV3A
SV3B
*3
7
SV42
HP
Accumulator
TD2
Compressor
2
Compressor
1
TD1
SV41
Compressor
2
SV41
SV3B
Balance pipe
*1 When liquid leaks from PMV, packed valve
Liquid pipe
at liquid side = Close fully
Gas pipe
*2 Gas pipe service valve = Close fully
*3 Balance pipe packed valve = Open fully
Gas pipe
Liquid pipe
Strainer
Strainer
Strainer
PMV
TC2
TCJ
Strainer
Strainer
PMV
TC1
TC2
TCJ
Strainer
Strainer
PMV
TC1
TC2
TCJ
Strainer
PMV
TC1
TC2
TCJ
TC1
Indoor unit
High-pressure gas or condensate liquid refrigerant
Evaporative gas refrigerant (Low-pressure gas)
NOTE
An outdoor unit which is connected with indoor/outdoor communication lines is
referred to as the ‘‘Header unit’’, and the other unit is called the ‘‘Follower unit’’.
(Example: 20HP system)
41
5. Recovery of Refrigerant in Failed Outdoor Unit
(In Case of Failure of Follower Unit)
Header unit
(MMY-MAP1001H)
Follower unit
(MMY-MAP1001H)
Failure
FM
FM
TE1
TE1
TO
PMV1
PMV2
TO
4-Way valve
SV5
PMV1
PMV2
4-Way valve
SV5
TS1
TS1
SV2
Pd sensor
TL
SV2
Pd sensor
TL
Ps sensor
Ps sensor
OS
OS
SV3D
SV3D
Liquid
tank
SV42
HP
HP
SV3C
TK3
TK1
SV3E
SV42
HP
Accumulator
TD2
HP
TK2
TK3
TK1
Oil tank
TK4
SV3C
TD1
Compressor
2
Compressor
1
TD1
SV41
SV3E
SV3A
Accumulator
TD2
Compressor
2
SV41
Compressor
1
7
Liquid
tank
TK2
Oil tank
TK4
SV3A
SV3B
SV3B
*1
Balance pipe
*2
Liquid pipe
*3
Gas pipe
*1 Packed valve of balance pipe = Open fully
*2 Packed valve at liquid side = Close fully
*3 Service valve open fully at gas side
Close fully 10 minutes after operation start
Gas pipe
Liquid pipe
Strainer
Strainer
Strainer
PMV
TC2
TCJ
Strainer
Strainer
PMV
TC1
TC2
TCJ
Strainer
Strainer
PMV
TC1
TC2
TCJ
Strainer
PMV
TC1
TC2
TCJ
TC1
Indoor unit
High-pressure gas or condensate liquid refrigerant
Evaporative gas refrigerant (Low-pressure gas)
NOTE
An outdoor unit which is connected with indoor/outdoor communication lines is
referred to as ‘‘Header unit’’, and the other unit is called the ‘‘Follower unit’’.
42
(Example: 20HP system)
8
Sensible capacity table
43
Foreword
44
8
Foreword
Sensible capacity
table
4-way Discharge Cassette Type ( MMU-AP****H)
unit
size
009
012
015
018
outdoor
air temp.
o
CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
o
14.0 CWB
o
20 CDB
TC
SHC
2.3
1.9
2.3
1.9
2.3
1.9
2.3
1.9
2.3
1.9
2.3
1.9
2.3
1.9
2.3
1.9
2.3
1.9
2.3
1.9
2.3
1.9
2.3
1.9
2.3
1.9
2.3
1.9
2.2
1.8
2.2
1.8
3.0
2.3
3.0
2.3
3.0
2.3
3.0
2.3
3.0
2.3
3.0
2.3
3.0
2.3
2.3
3.0
3.0
2.3
3.0
2.3
3.0
2.3
3.0
2.3
3.0
2.3
3.0
2.3
2.9
2.2
2.8
2.2
3.7
2.8
3.7
2.8
3.7
2.8
3.7
2.8
3.7
2.8
3.7
2.8
3.7
2.8
3.7
2.8
3.7
2.8
3.7
2.8
3.7
2.8
3.7
2.8
3.7
2.8
3.7
2.8
3.6
2.7
3.5
2.7
4.6
3.5
4.6
3.5
4.6
3.5
4.6
3.5
4.6
3.5
4.6
3.5
4.6
3.5
4.6
3.5
4.6
3.5
4.6
3.5
4.6
3.5
4.6
3.5
4.6
3.5
4.6
3.5
4.5
3.4
4.3
3.3
o
16.0 CWB
o
23 CDB
TC
SHC
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
1.9
2.4
1.9
3.3
2.5
3.3
2.5
3.3
2.5
3.3
2.5
3.3
2.5
3.3
2.5
3.3
2.5
3.3
2.5
3.3
2.5
3.3
2.5
3.3
2.5
3.3
2.5
3.3
2.5
3.3
2.5
3.2
2.4
3.1
2.3
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.0
2.9
3.8
2.8
5.1
3.8
5.1
3.8
5.1
3.8
5.1
3.8
5.1
3.8
5.1
3.8
5.1
3.8
5.1
3.8
5.1
3.8
5.1
3.8
5.1
3.8
5.1
3.8
5.1
3.8
5.1
3.8
4.9
3.7
4.8
3.6
TC : Total capacity [kW]
indoor air temp.
o
o
o
18.0 CWB
19.0 CWB
20.0 CWB
o
o
o
26 CDB
27 CDB
28 CDB
TC
SHC
TC
SHC
TC
SHC
2.7
2.1
2.8
2.1
2.9
2.1
2.7
2.1
2.8
2.1
2.9
2.1
2.7
2.1
2.8
2.1
2.9
2.1
2.7
2.1
2.8
2.1
2.9
2.1
2.7
2.1
2.8
2.1
2.9
2.1
2.7
2.1
2.8
2.1
2.9
2.1
2.7
2.1
2.8
2.1
2.9
2.1
2.7
2.1
2.8
2.1
2.9
2.1
2.7
2.1
2.8
2.1
2.9
2.1
2.7
2.1
2.8
2.1
2.9
2.1
2.7
2.1
2.8
2.1
2.9
2.1
2.7
2.1
2.8
2.1
2.9
2.1
2.7
2.1
2.8
2.1
2.9
2.1
2.7
2.1
2.8
2.1
2.9
2.1
2.6
2.0
2.7
2.0
2.8
2.0
2.6
2.0
2.6
2.0
2.7
2.0
3.5
2.6
3.6
2.6
3.7
2.6
3.5
2.6
3.6
2.6
3.7
2.6
3.5
2.6
3.6
2.6
3.7
2.6
3.5
2.6
3.6
2.6
3.7
2.6
3.5
2.6
3.6
2.6
3.7
2.6
3.5
2.6
3.6
2.6
3.7
2.6
3.5
2.6
3.6
2.6
3.7
2.6
3.5
2.6
3.6
2.6
3.7
2.6
3.5
2.6
3.6
2.6
3.7
2.6
3.5
2.6
3.6
2.6
3.7
2.6
3.5
2.6
3.6
2.6
3.7
2.6
3.5
2.6
3.6
2.6
3.7
2.6
3.5
2.6
3.6
2.6
3.7
2.6
3.5
2.6
3.6
2.6
3.7
2.6
3.4
2.5
3.5
2.5
3.6
2.5
3.3
2.5
3.4
2.4
3.5
2.4
4.4
3.2
4.5
3.2
4.6
3.2
4.4
3.2
4.5
3.2
4.6
3.2
4.4
3.2
4.5
3.2
4.6
3.2
4.4
3.2
4.5
3.2
4.6
3.2
4.4
3.2
4.5
3.2
4.6
3.2
4.4
3.2
4.5
3.2
4.6
3.2
4.4
3.2
4.5
3.2
4.6
3.2
4.4
3.2
4.5
3.2
4.6
3.2
4.4
3.2
4.5
3.2
4.6
3.2
4.4
3.2
4.5
3.2
4.6
3.2
4.4
3.2
4.5
3.2
4.6
3.2
4.4
3.2
4.5
3.2
4.6
3.2
4.4
3.2
4.5
3.2
4.6
3.2
4.4
3.2
4.5
3.2
4.6
3.2
4.2
3.1
4.4
3.1
4.5
3.1
4.1
3.0
4.2
3.0
4.4
3.0
5.4
4.0
5.6
4.0
5.8
4.0
5.4
4.0
5.6
4.0
5.8
4.0
5.4
4.0
5.6
4.0
5.8
4.0
5.4
4.0
5.6
4.0
5.8
4.0
5.4
4.0
5.6
4.0
5.8
4.0
5.4
4.0
5.6
4.0
5.8
4.0
5.4
4.0
5.6
4.0
5.8
4.0
5.4
4.0
5.6
4.0
5.8
4.0
5.4
4.0
5.6
4.0
5.8
4.0
5.4
4.0
5.6
4.0
5.8
4.0
5.4
4.0
5.6
4.0
5.8
4.0
5.4
4.0
5.6
4.0
5.8
4.0
5.4
4.0
5.6
4.0
5.8
4.0
5.4
4.0
5.6
4.0
5.8
4.0
5.3
3.9
5.4
3.9
5.6
3.9
5.1
3.8
5.3
3.8
5.4
3.8
SHC : Sensible capacity [kW]
o
22.0 CWB
o
30 CDB
TC
SHC
3.1
2.1
3.1
2.1
3.1
2.1
3.1
2.1
3.1
2.1
3.1
2.1
3.1
2.1
3.1
2.1
3.1
2.1
3.1
2.1
3.1
2.1
3.1
2.1
3.1
2.1
3.1
2.1
3.0
2.0
2.9
2.0
3.9
2.6
3.9
2.6
3.9
2.6
3.9
2.6
3.9
2.6
3.9
2.6
3.9
2.6
3.9
2.6
3.9
2.6
3.9
2.6
3.9
2.6
3.9
2.6
3.9
2.6
3.9
2.6
3.8
2.5
3.7
2.4
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.7
3.1
4.6
3.0
6.1
4.0
6.1
4.0
6.1
4.0
6.1
4.0
6.1
4.0
6.1
4.0
6.1
4.0
6.1
4.0
6.1
4.0
6.1
4.0
6.1
4.0
6.1
4.0
6.1
4.0
6.1
4.0
5.9
3.8
5.7
3.7
o
24.0 CWB
o
32 CDB
TC
SHC
3.2
2.0
3.2
2.0
3.2
2.0
3.2
2.0
3.2
2.0
3.2
2.0
3.2
2.0
3.2
2.0
3.2
2.0
3.2
2.0
3.2
2.0
3.2
2.0
3.2
2.0
3.2
2.0
3.1
2.0
3.0
1.9
4.1
2.5
4.1
2.5
4.1
2.5
4.1
2.5
4.1
2.5
4.1
2.5
4.1
2.5
4.1
2.5
4.1
2.5
4.1
2.5
4.1
2.5
4.1
2.5
4.1
2.5
4.1
2.5
4.0
2.4
3.9
2.4
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.0
3.0
4.8
2.9
6.4
3.9
6.4
3.9
6.4
3.9
6.4
3.9
6.4
3.9
6.4
3.9
6.4
3.9
6.4
3.9
6.4
3.9
6.4
3.9
6.4
3.9
6.4
3.9
6.4
3.9
6.4
3.9
6.2
3.7
6.0
3.6
8
45
4-way Discharge Cassette Type ( MMU-AP****H)
unit
size
024
8
027
030
036
46
outdoor
air temp.
o
CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
o
14.0 CWB
o
20 CDB
TC
SHC
5.8
4.3
5.8
4.3
5.8
4.3
5.8
4.3
5.8
4.3
5.8
4.3
5.8
4.3
5.8
4.3
5.8
4.3
5.8
4.3
5.8
4.3
5.8
4.3
5.8
4.3
5.8
4.3
5.6
4.2
5.5
4.1
6.6
4.9
6.6
4.9
6.6
4.9
6.6
4.9
6.6
4.9
6.6
4.9
6.6
4.9
6.6
4.9
6.6
4.9
6.6
4.9
6.6
4.9
6.6
4.9
6.6
4.9
6.6
4.9
6.4
4.7
6.2
4.6
7.4
5.5
7.4
5.5
7.4
5.5
7.4
5.5
7.4
5.5
7.4
5.5
7.4
5.5
7.4
5.5
7.4
5.5
7.4
5.5
7.4
5.5
7.4
5.5
7.4
5.5
7.4
5.5
7.2
5.3
7.0
5.2
9.2
6.8
9.2
6.8
9.2
6.8
9.2
6.8
9.2
6.8
9.2
6.8
9.2
6.8
9.2
6.8
9.2
6.8
9.2
6.8
9.2
6.8
9.2
6.8
9.2
6.8
9.2
6.8
8.9
6.6
8.7
6.4
o
16.0 CWB
o
23 CDB
TC
SHC
6.4
4.6
6.4
4.6
6.4
4.6
6.4
4.6
6.4
4.6
6.4
4.6
6.4
4.6
6.4
4.6
6.4
4.6
6.4
4.6
6.4
4.6
6.4
4.6
6.4
4.6
6.4
4.6
6.2
4.5
6.1
4.4
7.3
5.2
7.3
5.2
7.3
5.2
7.3
5.2
7.3
5.2
7.3
5.2
7.3
5.2
7.3
5.2
7.3
5.2
7.3
5.2
7.3
5.2
7.3
5.2
7.3
5.2
7.3
5.2
7.0
5.0
6.8
4.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
7.9
5.7
7.7
5.5
10.2
7.3
10.2
7.3
10.2
7.3
10.2
7.3
10.2
7.3
10.2
7.3
10.2
7.3
10.2
7.3
10.2
7.3
10.2
7.3
10.2
7.3
10.2
7.3
10.2
7.3
10.2
7.3
9.8
7.0
9.6
6.8
TC : Total capacity [kW]
indoor air temp.
o
o
o
18.0 CWB
19.0 CWB
20.0 CWB
o
o
o
26 CDB
27 CDB
28 CDB
TC
SHC
TC
SHC
TC
SHC
6.9
4.9
7.1
4.9
7.3
4.9
6.9
4.9
7.1
4.9
7.3
4.9
6.9
4.9
7.1
4.9
7.3
4.9
6.9
4.9
7.1
4.9
7.3
4.9
6.9
4.9
7.1
4.9
7.3
4.9
6.9
4.9
7.1
4.9
7.3
4.9
6.9
4.9
7.1
4.9
7.3
4.9
6.9
4.9
7.1
4.9
7.3
4.9
6.9
4.9
7.1
4.9
7.3
4.9
6.9
4.9
7.1
4.9
7.3
4.9
6.9
4.9
7.1
4.9
7.3
4.9
6.9
4.9
7.1
4.9
7.3
4.9
6.9
4.9
7.1
4.9
7.3
4.9
6.9
4.9
7.1
4.9
7.3
4.9
6.7
4.8
6.9
4.7
7.1
4.7
6.5
4.6
6.7
4.6
6.9
4.6
7.8
5.5
8.0
5.5
8.2
5.5
7.8
5.5
8.0
5.5
8.2
5.5
7.8
5.5
8.0
5.5
8.2
5.5
7.8
5.5
8.0
5.5
8.2
5.5
7.8
5.5
8.0
5.5
8.2
5.5
7.8
5.5
8.0
5.5
8.2
5.5
7.8
5.5
8.0
5.5
8.2
5.5
7.8
5.5
8.0
5.5
8.2
5.5
7.8
5.5
8.0
5.5
8.2
5.5
7.8
5.5
8.0
5.5
8.2
5.5
7.8
5.5
8.0
5.5
8.2
5.5
7.8
5.5
8.0
5.5
8.2
5.5
7.8
5.5
8.0
5.5
8.2
5.5
7.8
5.5
8.0
5.5
8.2
5.5
7.5
5.3
7.7
5.3
8.0
5.3
7.3
5.2
7.5
5.2
7.8
5.2
8.7
6.2
9.0
6.2
9.3
6.2
8.7
6.2
9.0
6.2
9.3
6.2
8.7
6.2
9.0
6.2
9.3
6.2
8.7
6.2
9.0
6.2
9.3
6.2
8.7
6.2
9.0
6.2
9.3
6.2
8.7
6.2
9.0
6.2
9.3
6.2
8.7
6.2
9.0
6.2
9.3
6.2
8.7
6.2
9.0
6.2
9.3
6.2
8.7
6.2
9.0
6.2
9.3
6.2
8.7
6.2
9.0
6.2
9.3
6.2
8.7
6.2
9.0
6.2
9.3
6.2
8.7
6.2
9.0
6.2
9.3
6.2
8.7
6.2
9.0
6.2
9.3
6.2
8.7
6.2
9.0
6.2
9.3
6.2
8.5
6.0
8.7
6.0
9.0
6.0
8.2
5.9
8.5
5.8
8.7
5.8
10.9
7.7
11.2
7.7
11.5
7.7
10.9
7.7
11.2
7.7
11.5
7.7
10.9
7.7
11.2
7.7
11.5
7.7
10.9
7.7
11.2
7.7
11.5
7.7
10.9
7.7
11.2
7.7
11.5
7.7
10.9
7.7
11.2
7.7
11.5
7.7
10.9
7.7
11.2
7.7
11.5
7.7
10.9
7.7
11.2
7.7
11.5
7.7
10.9
7.7
11.2
7.7
11.5
7.7
10.9
7.7
11.2
7.7
11.5
7.7
10.9
7.7
11.2
7.7
11.5
7.7
10.9
7.7
11.2
7.7
11.5
7.7
10.9
7.7
11.2
7.7
11.5
7.7
10.9
7.7
11.2
7.7
11.5
7.7
10.5
7.5
10.8
7.5
11.2
7.5
10.2
7.3
10.5
7.2
10.9
7.2
SHC : Sensible capacity [kW]
o
22.0 CWB
o
30 CDB
TC
SHC
7.7
4.9
7.7
4.9
7.7
4.9
7.7
4.9
7.7
4.9
7.7
4.9
7.7
4.9
7.7
4.9
7.7
4.9
7.7
4.9
7.7
4.9
7.7
4.9
7.7
4.9
7.7
4.9
7.5
4.7
7.3
4.6
8.7
5.4
8.7
5.4
8.7
5.4
8.7
5.4
8.7
5.4
8.7
5.4
8.7
5.4
8.7
5.4
8.7
5.4
8.7
5.4
8.7
5.4
8.7
5.4
8.7
5.4
8.7
5.4
8.4
5.3
8.2
5.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.5
5.9
9.2
5.8
12.2
7.6
12.2
7.6
12.2
7.6
12.2
7.6
12.2
7.6
12.2
7.6
12.2
7.6
12.2
7.6
12.2
7.6
12.2
7.6
12.2
7.6
12.2
7.6
12.2
7.6
12.2
7.6
11.8
7.4
11.5
7.2
o
24.0 CWB
o
32 CDB
TC
SHC
8.1
4.7
8.1
4.7
8.1
4.7
8.1
4.7
8.1
4.7
8.1
4.7
8.1
4.7
8.1
4.7
8.1
4.7
8.1
4.7
8.1
4.7
8.1
4.7
8.1
4.7
8.1
4.7
7.8
4.6
7.6
4.5
9.1
5.3
9.1
5.3
9.1
5.3
9.1
5.3
9.1
5.3
9.1
5.3
9.1
5.3
9.1
5.3
9.1
5.3
9.1
5.3
9.1
5.3
9.1
5.3
9.1
5.3
9.1
5.3
8.8
5.2
8.6
5.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
9.9
5.8
9.7
5.6
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.4
7.2
12.0
7.0
Foreword
4-way Discharge Cassette Type ( MMU-AP****H)
unit
size
048
056
outdoor
air temp.
o
CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
o
14.0 CWB
o
20 CDB
TC
SHC
11.5
8.7
11.5
8.7
11.5
8.7
11.5
8.7
11.5
8.7
11.5
8.7
11.5
8.7
11.5
8.7
11.5
8.7
11.5
8.7
11.5
8.7
11.5
8.7
11.5
8.7
11.5
8.7
11.1
8.4
10.8
8.2
13.1
9.8
13.1
9.8
13.1
9.8
13.1
9.8
13.1
9.8
13.1
9.8
13.1
9.8
13.1
9.8
13.1
9.8
13.1
9.8
13.1
9.8
13.1
9.8
13.1
9.8
13.1
9.8
12.7
9.4
12.4
9.2
o
16.0 CWB
o
23 CDB
TC
SHC
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.3
9.0
12.0
8.7
14.5
10.4
14.5
10.4
14.5
10.4
14.5
10.4
14.5
10.4
14.5
10.4
14.5
10.4
14.5
10.4
14.5
10.4
14.5
10.4
14.5
10.4
14.5
10.4
14.5
10.4
14.5
10.4
14.1
10.1
13.7
9.8
TC : Total capacity [kW]
indoor air temp.
o
o
o
18.0 CWB
19.0 CWB
20.0 CWB
o
o
o
26 CDB
27 CDB
28 CDB
TC
SHC
TC
SHC
TC
SHC
13.6
9.8
14.0
9.8
14.4
9.8
13.6
9.8
14.0
9.8
14.4
9.8
13.6
9.8
14.0
9.8
14.4
9.8
13.6
9.8
14.0
9.8
14.4
9.8
13.6
9.8
14.0
9.8
14.4
9.8
13.6
9.8
14.0
9.8
14.4
9.8
13.6
9.8
14.0
9.8
14.4
9.8
13.6
9.8
14.0
9.8
14.4
9.8
13.6
9.8
14.0
9.8
14.4
9.8
13.6
9.8
14.0
9.8
14.4
9.8
13.6
9.8
14.0
9.8
14.4
9.8
13.6
9.8
14.0
9.8
14.4
9.8
13.6
9.8
14.0
9.8
14.4
9.8
13.6
9.8
14.0
9.8
14.4
9.8
13.1
9.5
13.6
9.5
14.0
9.5
12.8
9.2
13.2
9.2
13.6
9.2
15.5
11.0
16.0
11.0
16.5
11.0
15.5
11.0
16.0
11.0
16.5
11.0
15.5
11.0
16.0
11.0
16.5
11.0
15.5
11.0
16.0
11.0
16.5
11.0
15.5
11.0
16.0
11.0
16.5
11.0
15.5
11.0
16.0
11.0
16.5
11.0
15.5
11.0
16.0
11.0
16.5
11.0
15.5
11.0
16.0
11.0
16.5
11.0
15.5
11.0
16.0
11.0
16.5
11.0
15.5
11.0
16.0
11.0
16.5
11.0
15.5
11.0
16.0
11.0
16.5
11.0
15.5
11.0
16.0
11.0
16.5
11.0
15.5
11.0
16.0
11.0
16.5
11.0
15.5
11.0
16.0
11.0
16.5
11.0
15.0
10.7
15.5
10.6
16.0
10.6
14.6
10.4
15.1
10.4
15.5
10.4
SHC : Sensible capacity [kW]
o
22.0 CWB
o
30 CDB
TC
SHC
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
14.8
9.4
14.4
9.1
17.4
10.9
17.4
10.9
17.4
10.9
17.4
10.9
17.4
10.9
17.4
10.9
17.4
10.9
17.4
10.9
17.4
10.9
17.4
10.9
17.4
10.9
17.4
10.9
17.4
10.9
17.4
10.9
16.9
10.5
16.4
10.3
o
24.0 CWB
o
32 CDB
TC
SHC
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
15.4
9.2
15.0
8.9
18.2
10.6
18.2
10.6
18.2
10.6
18.2
10.6
18.2
10.6
18.2
10.6
18.2
10.6
18.2
10.6
18.2
10.6
18.2
10.6
18.2
10.6
18.2
10.6
18.2
10.6
18.2
10.6
17.7
10.3
17.2
10.0
8
47
2-way Air Discharge Cassette Type ( MMU-AP****WH) TC : Total capacity [kW]
unit
size
007
8
009
012
015
48
outdoor
air temp.
o
CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
o
14.0 CWB
o
20 CDB
TC
SHC
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.7
1.5
1.7
1.4
2.3
1.8
2.3
1.8
2.3
1.8
2.3
1.8
2.3
1.8
2.3
1.8
2.3
1.8
2.3
1.8
2.3
1.8
2.3
1.8
2.3
1.8
2.3
1.8
2.3
1.8
2.3
1.8
2.2
1.7
2.2
1.7
3.0
2.0
3.0
2.0
3.0
2.0
3.0
2.0
3.0
2.0
3.0
2.0
3.0
2.0
3.0
2.0
3.0
2.0
3.0
2.0
3.0
2.0
3.0
2.0
3.0
2.0
3.0
2.0
2.9
2.0
2.8
1.9
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.6
2.6
3.5
2.5
o
16.0 CWB
o
23 CDB
TC
SHC
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
1.9
1.6
1.9
1.5
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.8
2.4
1.8
3.3
2.2
3.3
2.2
3.3
2.2
3.3
2.2
3.3
2.2
3.3
2.2
3.3
2.2
3.3
2.2
3.3
2.2
3.3
2.2
3.3
2.2
3.3
2.2
3.3
2.2
3.3
2.2
3.2
2.1
3.1
2.0
4.1
2.9
4.1
2.9
4.1
2.9
4.1
2.9
4.1
2.9
4.1
2.9
4.1
2.9
4.1
2.9
4.1
2.9
4.1
2.9
4.1
2.9
4.1
2.9
4.1
2.9
4.1
2.9
4.0
2.8
3.8
2.7
indoor air temp.
o
o
18.0 CWB
19.0 CWB
o
o
26 CDB
27 CDB
TC
SHC
TC
SHC
2.1
1.7
2.2
1.7
2.1
1.7
2.2
1.7
2.1
1.7
2.2
1.7
2.1
1.7
2.2
1.7
2.1
1.7
2.2
1.7
2.1
1.7
2.2
1.7
2.1
1.7
2.2
1.7
2.1
1.7
2.2
1.7
2.1
1.7
2.2
1.7
2.1
1.7
2.2
1.7
2.1
1.7
2.2
1.7
2.1
1.7
2.2
1.7
2.1
1.7
2.2
1.7
2.1
1.7
2.2
1.7
2.1
1.7
2.1
1.6
2.0
1.6
2.1
1.6
2.7
2.0
2.8
2.0
2.7
2.0
2.8
2.0
2.7
2.0
2.8
2.0
2.7
2.0
2.8
2.0
2.7
2.0
2.8
2.0
2.7
2.0
2.8
2.0
2.7
2.0
2.8
2.0
2.7
2.0
2.8
2.0
2.7
2.0
2.8
2.0
2.7
2.0
2.8
2.0
2.7
2.0
2.8
2.0
2.7
2.0
2.8
2.0
2.7
2.0
2.8
2.0
2.7
2.0
2.8
2.0
2.6
1.9
2.7
1.9
2.6
1.9
2.6
1.9
3.5
2.3
3.6
2.3
3.5
2.3
3.6
2.3
3.5
2.3
3.6
2.3
3.5
2.3
3.6
2.3
3.5
2.3
3.6
2.3
3.5
2.3
3.6
2.3
3.5
2.3
3.6
2.3
3.5
2.3
3.6
2.3
3.5
2.3
3.6
2.3
3.5
2.3
3.6
2.3
3.5
2.3
3.6
2.3
3.5
2.3
3.6
2.3
3.5
2.3
3.6
2.3
3.5
2.3
3.6
2.3
3.4
2.2
3.5
2.2
3.3
2.2
3.4
2.2
4.4
3.1
4.5
3.1
4.4
3.1
4.5
3.1
4.4
3.1
4.5
3.1
4.4
3.1
4.5
3.1
4.4
3.1
4.5
3.1
4.4
3.1
4.5
3.1
4.4
3.1
4.5
3.1
4.4
3.1
4.5
3.1
4.4
3.1
4.5
3.1
4.4
3.1
4.5
3.1
4.4
3.1
4.5
3.1
4.4
3.1
4.5
3.1
4.4
3.1
4.5
3.1
4.4
3.1
4.5
3.1
4.2
3.0
4.4
3.0
4.1
2.9
4.2
2.9
o
20.0 CWB
o
28 CDB
TC
SHC
2.3
1.7
2.3
1.7
2.3
1.7
2.3
1.7
2.3
1.7
2.3
1.7
2.3
1.7
2.3
1.7
2.3
1.7
2.3
1.7
2.3
1.7
2.3
1.7
2.3
1.7
2.3
1.7
2.2
1.6
2.1
1.6
2.9
2.0
2.9
2.0
2.9
2.0
2.9
2.0
2.9
2.0
2.9
2.0
2.9
2.0
2.9
2.0
2.9
2.0
2.9
2.0
2.9
2.0
2.9
2.0
2.9
2.0
2.9
2.0
2.8
1.9
2.7
1.9
3.7
2.3
3.7
2.3
3.7
2.3
3.7
2.3
3.7
2.3
3.7
2.3
3.7
2.3
3.7
2.3
3.7
2.3
3.7
2.3
3.7
2.3
3.7
2.3
3.7
2.3
3.7
2.3
3.6
2.2
3.5
2.2
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.5
3.0
4.4
2.9
SHC : Sensible capacity [kW]
o
22.0 CWB
o
30 CDB
TC
SHC
2.4
1.7
2.4
1.7
2.4
1.7
2.4
1.7
2.4
1.7
2.4
1.7
2.4
1.7
2.4
1.7
2.4
1.7
2.4
1.7
2.4
1.7
2.4
1.7
2.4
1.7
2.4
1.7
2.3
1.6
2.3
1.6
3.1
2.0
3.1
2.0
3.1
2.0
3.1
2.0
3.1
2.0
3.1
2.0
3.1
2.0
3.1
2.0
3.1
2.0
3.1
2.0
3.1
2.0
3.1
2.0
3.1
2.0
3.1
2.0
3.0
1.9
2.9
1.9
3.9
2.3
3.9
2.3
3.9
2.3
3.9
2.3
3.9
2.3
3.9
2.3
3.9
2.3
3.9
2.3
3.9
2.3
3.9
2.3
3.9
2.3
3.9
2.3
3.9
2.3
3.9
2.3
3.8
2.2
3.7
2.1
4.9
3.0
4.9
3.0
4.9
3.0
4.9
3.0
4.9
3.0
4.9
3.0
4.9
3.0
4.9
3.0
4.9
3.0
4.9
3.0
4.9
3.0
4.9
3.0
4.9
3.0
4.9
3.0
4.7
2.9
4.6
2.8
o
24.0 CWB
o
32 CDB
TC
SHC
2.5
1.6
2.5
1.6
2.5
1.6
2.5
1.6
2.5
1.6
2.5
1.6
2.5
1.6
2.5
1.6
2.5
1.6
2.5
1.6
2.5
1.6
2.5
1.6
2.5
1.6
2.5
1.6
2.4
1.6
2.4
1.5
3.2
1.9
3.2
1.9
3.2
1.9
3.2
1.9
3.2
1.9
3.2
1.9
3.2
1.9
3.2
1.9
3.2
1.9
3.2
1.9
3.2
1.9
3.2
1.9
3.2
1.9
3.2
1.9
3.1
1.9
3.0
1.8
4.1
2.2
4.1
2.2
4.1
2.2
4.1
2.2
4.1
2.2
4.1
2.2
4.1
2.2
4.1
2.2
4.1
2.2
4.1
2.2
4.1
2.2
4.1
2.2
4.1
2.2
4.1
2.2
4.0
2.2
3.9
2.1
5.1
3.0
5.1
3.0
5.1
3.0
5.1
3.0
5.1
3.0
5.1
3.0
5.1
3.0
5.1
3.0
5.1
3.0
5.1
3.0
5.1
3.0
5.1
3.0
5.1
3.0
5.1
3.0
5.0
2.9
4.8
2.8
2-way Air Discharge Cassette Type ( MMU-AP****WH) TC : Total capacity [kW]
unit
size
018
024
027
030
outdoor
air temp.
o
CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
o
14.0 CWB
o
20 CDB
TC
SHC
4.6
3.4
4.6
3.4
4.6
3.4
4.6
3.4
4.6
3.4
4.6
3.4
4.6
3.4
4.6
3.4
4.6
3.4
4.6
3.4
4.6
3.4
4.6
3.4
4.6
3.4
4.6
3.4
4.5
3.3
4.3
3.2
5.8
4.3
5.8
4.3
5.8
4.3
5.8
4.3
5.8
4.3
5.8
4.3
5.8
4.3
5.8
4.3
5.8
4.3
5.8
4.3
5.8
4.3
5.8
4.3
5.8
4.3
5.8
4.3
5.6
4.1
5.5
4.0
6.6
4.9
6.6
4.9
6.6
4.9
6.6
4.9
6.6
4.9
6.6
4.9
6.6
4.9
6.6
4.9
6.6
4.9
6.6
4.9
6.6
4.9
6.6
4.9
6.6
4.9
6.6
4.9
6.4
4.7
6.2
4.6
7.4
5.3
7.4
5.3
7.4
5.3
7.4
5.3
7.4
5.3
7.4
5.3
7.4
5.3
7.4
5.3
7.4
5.3
7.4
5.3
7.4
5.3
7.4
5.3
7.4
5.3
7.4
5.3
7.2
5.1
7.0
5.0
o
16.0 CWB
o
23 CDB
TC
SHC
5.1
3.6
5.1
3.6
5.1
3.6
5.1
3.6
5.1
3.6
5.1
3.6
5.1
3.6
5.1
3.6
5.1
3.6
5.1
3.6
5.1
3.6
5.1
3.6
5.1
3.6
5.1
3.6
4.9
3.5
4.8
3.4
6.4
4.5
6.4
4.5
6.4
4.5
6.4
4.5
6.4
4.5
6.4
4.5
6.4
4.5
6.4
4.5
6.4
4.5
6.4
4.5
6.4
4.5
6.4
4.5
6.4
4.5
6.4
4.5
6.2
4.4
6.1
4.3
7.3
5.2
7.3
5.2
7.3
5.2
7.3
5.2
7.3
5.2
7.3
5.2
7.3
5.2
7.3
5.2
7.3
5.2
7.3
5.2
7.3
5.2
7.3
5.2
7.3
5.2
7.3
5.2
7.0
5.0
6.8
4.9
8.2
5.7
8.2
5.7
8.2
5.7
8.2
5.7
8.2
5.7
8.2
5.7
8.2
5.7
8.2
5.7
8.2
5.7
8.2
5.7
8.2
5.7
8.2
5.7
8.2
5.7
8.2
5.7
7.9
5.5
7.7
5.3
indoor air temp.
o
o
18.0 CWB
19.0 CWB
o
o
26 CDB
27 CDB
TC
SHC
TC
SHC
5.4
3.8
5.6
3.8
5.4
3.8
5.6
3.8
5.4
3.8
5.6
3.8
5.4
3.8
5.6
3.8
5.4
3.8
5.6
3.8
5.4
3.8
5.6
3.8
5.4
3.8
5.6
3.8
5.4
3.8
5.6
3.8
5.4
3.8
5.6
3.8
5.4
3.8
5.6
3.8
5.4
3.8
5.6
3.8
5.4
3.8
5.6
3.8
5.4
3.8
5.6
3.8
5.4
3.8
5.6
3.8
5.3
3.7
5.4
3.7
5.1
3.6
5.3
3.6
6.9
4.8
7.1
4.8
6.9
4.8
7.1
4.8
6.9
4.8
7.1
4.8
6.9
4.8
7.1
4.8
6.9
4.8
7.1
4.8
6.9
4.8
7.1
4.8
6.9
4.8
7.1
4.8
6.9
4.8
7.1
4.8
6.9
4.8
7.1
4.8
6.9
4.8
7.1
4.8
6.9
4.8
7.1
4.8
6.9
4.8
7.1
4.8
6.9
4.8
7.1
4.8
6.9
4.8
7.1
4.8
6.7
4.7
6.9
4.6
6.5
4.5
6.7
4.5
7.8
5.5
8.0
5.5
7.8
5.5
8.0
5.5
7.8
5.5
8.0
5.5
7.8
5.5
8.0
5.5
7.8
5.5
8.0
5.5
7.8
5.5
8.0
5.5
7.8
5.5
8.0
5.5
7.8
5.5
8.0
5.5
7.8
5.5
8.0
5.5
7.8
5.5
8.0
5.5
7.8
5.5
8.0
5.5
7.8
5.5
8.0
5.5
7.8
5.5
8.0
5.5
7.8
5.5
8.0
5.5
7.5
5.3
7.7
5.3
7.3
5.2
7.5
5.2
8.7
6.0
9.0
6.0
8.7
6.0
9.0
6.0
8.7
6.0
9.0
6.0
8.7
6.0
9.0
6.0
8.7
6.0
9.0
6.0
8.7
6.0
9.0
6.0
8.7
6.0
9.0
6.0
8.7
6.0
9.0
6.0
8.7
6.0
9.0
6.0
8.7
6.0
9.0
6.0
8.7
6.0
9.0
6.0
8.7
6.0
9.0
6.0
8.7
6.0
9.0
6.0
8.7
6.0
9.0
6.0
8.5
5.8
8.7
5.8
8.2
5.7
8.5
5.6
o
20.0 CWB
o
28 CDB
TC
SHC
5.8
3.8
5.8
3.8
5.8
3.8
5.8
3.8
5.8
3.8
5.8
3.8
5.8
3.8
5.8
3.8
5.8
3.8
5.8
3.8
5.8
3.8
5.8
3.8
5.8
3.8
5.8
3.8
5.6
3.7
5.4
3.6
7.3
4.8
7.3
4.8
7.3
4.8
7.3
4.8
7.3
4.8
7.3
4.8
7.3
4.8
7.3
4.8
7.3
4.8
7.3
4.8
7.3
4.8
7.3
4.8
7.3
4.8
7.3
4.8
7.1
4.6
6.9
4.5
8.2
5.5
8.2
5.5
8.2
5.5
8.2
5.5
8.2
5.5
8.2
5.5
8.2
5.5
8.2
5.5
8.2
5.5
8.2
5.5
8.2
5.5
8.2
5.5
8.2
5.5
8.2
5.5
8.0
5.3
7.8
5.2
9.3
6.0
9.3
6.0
9.3
6.0
9.3
6.0
9.3
6.0
9.3
6.0
9.3
6.0
9.3
6.0
9.3
6.0
9.3
6.0
9.3
6.0
9.3
6.0
9.3
6.0
9.3
6.0
9.0
5.8
8.7
5.6
SHC : Sensible capacity [kW]
o
22.0 CWB
o
30 CDB
TC
SHC
6.1
3.8
6.1
3.8
6.1
3.8
6.1
3.8
6.1
3.8
6.1
3.8
6.1
3.8
6.1
3.8
6.1
3.8
6.1
3.8
6.1
3.8
6.1
3.8
6.1
3.8
6.1
3.8
5.9
3.6
5.7
3.5
7.7
4.8
7.7
4.8
7.7
4.8
7.7
4.8
7.7
4.8
7.7
4.8
7.7
4.8
7.7
4.8
7.7
4.8
7.7
4.8
7.7
4.8
7.7
4.8
7.7
4.8
7.7
4.8
7.5
4.6
7.3
4.5
8.7
5.4
8.7
5.4
8.7
5.4
8.7
5.4
8.7
5.4
8.7
5.4
8.7
5.4
8.7
5.4
8.7
5.4
8.7
5.4
8.7
5.4
8.7
5.4
8.7
5.4
8.7
5.4
8.4
5.3
8.2
5.1
9.8
5.9
9.8
5.9
9.8
5.9
9.8
5.9
9.8
5.9
9.8
5.9
9.8
5.9
9.8
5.9
9.8
5.9
9.8
5.9
9.8
5.9
9.8
5.9
9.8
5.9
9.8
5.9
9.5
5.8
9.2
5.6
o
24.0 CWB
o
32 CDB
TC
SHC
6.4
3.7
6.4
3.7
6.4
3.7
6.4
3.7
6.4
3.7
6.4
3.7
6.4
3.7
6.4
3.7
6.4
3.7
6.4
3.7
6.4
3.7
6.4
3.7
6.4
3.7
6.4
3.7
6.2
3.6
6.0
3.5
8.1
4.6
8.1
4.6
8.1
4.6
8.1
4.6
8.1
4.6
8.1
4.6
8.1
4.6
8.1
4.6
8.1
4.6
8.1
4.6
8.1
4.6
8.1
4.6
8.1
4.6
8.1
4.6
7.8
4.5
7.6
4.4
9.1
5.3
9.1
5.3
9.1
5.3
9.1
5.3
9.1
5.3
9.1
5.3
9.1
5.3
9.1
5.3
9.1
5.3
9.1
5.3
9.1
5.3
9.1
5.3
9.1
5.3
9.1
5.3
8.8
5.2
8.6
5.0
10.3
5.8
10.3
5.8
10.3
5.8
10.3
5.8
10.3
5.8
10.3
5.8
10.3
5.8
10.3
5.8
10.3
5.8
10.3
5.8
10.3
5.8
10.3
5.8
10.3
5.8
10.3
5.8
9.9
5.6
9.7
5.5
8
49
2-way Air Discharge Cassette Type ( MMU-AP****WH) TC : Total capacity [kW]
unit
size
048
8
50
outdoor
air temp.
o
CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
o
14.0 CWB
o
20 CDB
TC
SHC
11.5
8.4
11.5
8.4
11.5
8.4
11.5
8.4
11.5
8.4
11.5
8.4
11.5
8.4
11.5
8.4
11.5
8.4
11.5
8.4
11.5
8.4
11.5
8.4
11.5
8.4
11.5
8.4
11.1
8.2
10.8
7.9
o
16.0 CWB
o
23 CDB
TC
SHC
12.7
9.0
12.7
9.0
12.7
9.0
12.7
9.0
12.7
9.0
12.7
9.0
12.7
9.0
12.7
9.0
12.7
9.0
12.7
9.0
12.7
9.0
12.7
9.0
12.7
9.0
12.7
9.0
12.3
8.7
12.0
8.4
indoor air temp.
o
o
18.0 CWB
19.0 CWB
o
o
26 CDB
27 CDB
TC
SHC
TC
SHC
13.6
9.5
14.0
9.5
13.6
9.5
14.0
9.5
13.6
9.5
14.0
9.5
13.6
9.5
14.0
9.5
13.6
9.5
14.0
9.5
13.6
9.5
14.0
9.5
13.6
9.5
14.0
9.5
13.6
9.5
14.0
9.5
13.6
9.5
14.0
9.5
13.6
9.5
14.0
9.5
13.6
9.5
14.0
9.5
13.6
9.5
14.0
9.5
13.6
9.5
14.0
9.5
13.6
9.5
14.0
9.5
13.1
9.2
13.6
9.2
12.8
9.0
13.2
8.9
o
20.0 CWB
o
28 CDB
TC
SHC
14.4
9.5
14.4
9.5
14.4
9.5
14.4
9.5
14.4
9.5
14.4
9.5
14.4
9.5
14.4
9.5
14.4
9.5
14.4
9.5
14.4
9.5
14.4
9.5
14.4
9.5
14.4
9.5
14.0
9.2
13.6
8.9
SHC : Sensible capacity [kW]
o
22.0 CWB
o
30 CDB
TC
SHC
15.3
9.4
15.3
9.4
15.3
9.4
15.3
9.4
15.3
9.4
15.3
9.4
15.3
9.4
15.3
9.4
15.3
9.4
15.3
9.4
15.3
9.4
15.3
9.4
15.3
9.4
15.3
9.4
14.8
9.1
14.4
8.9
o
24.0 CWB
o
32 CDB
TC
SHC
16.0
9.2
16.0
9.2
16.0
9.2
16.0
9.2
16.0
9.2
16.0
9.2
16.0
9.2
16.0
9.2
16.0
9.2
16.0
9.2
16.0
9.2
16.0
9.2
16.0
9.2
16.0
9.2
15.4
8.9
15.0
8.7
1-way Air Discharge Cassette Type ( MMU-AP****YH [007
unit
size
007
009
012
015
outdoor
air temp.
o
CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
o
14.0 CWB
o
20 CDB
TC
SHC
1.8
1.6
1.8
1.6
1.8
1.6
1.8
1.6
1.8
1.6
1.8
1.6
1.8
1.6
1.8
1.6
1.8
1.6
1.8
1.6
1.8
1.6
1.8
1.6
1.8
1.6
1.8
1.6
1.7
1.5
1.7
1.5
2.3
2.0
2.3
2.0
2.3
2.0
2.3
2.0
2.3
2.0
2.3
2.0
2.3
2.0
2.3
2.0
2.3
2.0
2.3
2.0
2.3
2.0
2.3
2.0
2.3
2.0
2.3
2.0
2.2
1.9
2.2
1.8
3.0
2.4
3.0
2.4
3.0
2.4
3.0
2.4
3.0
2.4
3.0
2.4
3.0
2.4
3.0
2.4
3.0
2.4
3.0
2.4
3.0
2.4
3.0
2.4
3.0
2.4
3.0
2.4
2.9
2.3
2.8
2.3
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.6
2.6
3.5
2.5
o
16.0 CWB
o
23 CDB
TC
SHC
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
1.9
1.6
1.9
1.6
2.5
2.1
2.5
2.1
2.5
2.1
2.5
2.1
2.5
2.1
2.5
2.1
2.5
2.1
2.5
2.1
2.5
2.1
2.5
2.1
2.5
2.1
2.5
2.1
2.5
2.1
2.5
2.1
2.5
2.0
2.4
2.0
3.3
2.5
3.3
2.5
3.3
2.5
3.3
2.5
3.3
2.5
3.3
2.5
3.3
2.5
3.3
2.5
3.3
2.5
3.3
2.5
3.3
2.5
3.3
2.5
3.3
2.5
3.3
2.5
3.2
2.5
3.1
2.4
4.1
2.9
4.1
2.9
4.1
2.9
4.1
2.9
4.1
2.9
4.1
2.9
4.1
2.9
4.1
2.9
4.1
2.9
4.1
2.9
4.1
2.9
4.1
2.9
4.1
2.9
4.1
2.9
4.0
2.8
3.8
2.7
012] , -AP****SH [015
TC : Total capacity [kW]
indoor air temp.
o
o
o
18.0 CWB
19.0 CWB
20.0 CWB
o
o
o
26 CDB
27 CDB
28 CDB
TC
SHC
TC
SHC
TC
SHC
2.1
1.8
2.2
1.8
2.3
1.8
2.1
1.8
2.2
1.8
2.3
1.8
2.1
1.8
2.2
1.8
2.3
1.8
2.1
1.8
2.2
1.8
2.3
1.8
2.1
1.8
2.2
1.8
2.3
1.8
2.1
1.8
2.2
1.8
2.3
1.8
2.1
1.8
2.2
1.8
2.3
1.8
2.1
1.8
2.2
1.8
2.3
1.8
2.1
1.8
2.2
1.8
2.3
1.8
2.1
1.8
2.2
1.8
2.3
1.8
2.1
1.8
2.2
1.8
2.3
1.8
2.1
1.8
2.2
1.8
2.3
1.8
2.1
1.8
2.2
1.8
2.3
1.8
2.1
1.8
2.2
1.8
2.3
1.8
2.1
1.7
2.1
1.7
2.2
1.7
2.0
1.7
2.1
1.7
2.1
1.7
2.7
2.2
2.8
2.2
2.9
2.2
2.7
2.2
2.8
2.2
2.9
2.2
2.7
2.2
2.8
2.2
2.9
2.2
2.7
2.2
2.8
2.2
2.9
2.2
2.7
2.2
2.8
2.2
2.9
2.2
2.7
2.2
2.8
2.2
2.9
2.2
2.7
2.2
2.8
2.2
2.9
2.2
2.7
2.2
2.8
2.2
2.9
2.2
2.7
2.2
2.8
2.2
2.9
2.2
2.7
2.2
2.8
2.2
2.9
2.2
2.7
2.2
2.8
2.2
2.9
2.2
2.7
2.2
2.8
2.2
2.9
2.2
2.7
2.2
2.8
2.2
2.9
2.2
2.7
2.2
2.8
2.2
2.9
2.2
2.6
2.1
2.7
2.1
2.8
2.1
2.6
2.1
2.6
2.1
2.7
2.1
3.5
2.7
3.6
2.7
3.7
2.7
3.5
2.7
3.6
2.7
3.7
2.7
3.5
2.7
3.6
2.7
3.7
2.7
3.5
2.7
3.6
2.7
3.7
2.7
3.5
2.7
3.6
2.7
3.7
2.7
3.5
2.7
3.6
2.7
3.7
2.7
3.5
2.7
3.6
2.7
3.7
2.7
3.5
2.7
3.6
2.7
3.7
2.7
3.5
2.7
3.6
2.7
3.7
2.7
3.5
2.7
3.6
2.7
3.7
2.7
3.5
2.7
3.6
2.7
3.7
2.7
3.5
2.7
3.6
2.7
3.7
2.7
3.5
2.7
3.6
2.7
3.7
2.7
3.5
2.7
3.6
2.7
3.7
2.7
3.4
2.6
3.5
2.6
3.6
2.6
3.3
2.5
3.4
2.5
3.5
2.5
4.4
3.1
4.5
3.1
4.6
3.1
4.4
3.1
4.5
3.1
4.6
3.1
4.4
3.1
4.5
3.1
4.6
3.1
4.4
3.1
4.5
3.1
4.6
3.1
4.4
3.1
4.5
3.1
4.6
3.1
4.4
3.1
4.5
3.1
4.6
3.1
4.4
3.1
4.5
3.1
4.6
3.1
4.4
3.1
4.5
3.1
4.6
3.1
4.4
3.1
4.5
3.1
4.6
3.1
4.4
3.1
4.5
3.1
4.6
3.1
4.4
3.1
4.5
3.1
4.6
3.1
4.4
3.1
4.5
3.1
4.6
3.1
4.4
3.1
4.5
3.1
4.6
3.1
4.4
3.1
4.5
3.1
4.6
3.1
4.2
3.0
4.4
3.0
4.5
3.0
4.1
2.9
4.2
2.9
4.4
2.9
024] )
SHC : Sensible capacity [kW]
o
22.0 CWB
o
30 CDB
TC
SHC
2.4
1.8
2.4
1.8
2.4
1.8
2.4
1.8
2.4
1.8
2.4
1.8
2.4
1.8
2.4
1.8
2.4
1.8
2.4
1.8
2.4
1.8
2.4
1.8
2.4
1.8
2.4
1.8
2.3
1.7
2.3
1.7
3.1
2.2
3.1
2.2
3.1
2.2
3.1
2.2
3.1
2.2
3.1
2.2
3.1
2.2
3.1
2.2
3.1
2.2
3.1
2.2
3.1
2.2
3.1
2.2
3.1
2.2
3.1
2.2
3.0
2.1
2.9
2.1
3.9
2.7
3.9
2.7
3.9
2.7
3.9
2.7
3.9
2.7
3.9
2.7
3.9
2.7
3.9
2.7
3.9
2.7
3.9
2.7
3.9
2.7
3.9
2.7
3.9
2.7
3.9
2.7
3.8
2.6
3.7
2.5
4.9
3.0
4.9
3.0
4.9
3.0
4.9
3.0
4.9
3.0
4.9
3.0
4.9
3.0
4.9
3.0
4.9
3.0
4.9
3.0
4.9
3.0
4.9
3.0
4.9
3.0
4.9
3.0
4.7
2.9
4.6
2.8
o
24.0 CWB
o
32 CDB
TC
SHC
2.5
1.7
2.5
1.7
2.5
1.7
2.5
1.7
2.5
1.7
2.5
1.7
2.5
1.7
2.5
1.7
2.5
1.7
2.5
1.7
2.5
1.7
2.5
1.7
2.5
1.7
2.5
1.7
2.4
1.7
2.4
1.6
3.2
2.1
3.2
2.1
3.2
2.1
3.2
2.1
3.2
2.1
3.2
2.1
3.2
2.1
3.2
2.1
3.2
2.1
3.2
2.1
3.2
2.1
3.2
2.1
3.2
2.1
3.2
2.1
3.1
2.1
3.0
2.0
4.1
2.6
4.1
2.6
4.1
2.6
4.1
2.6
4.1
2.6
4.1
2.6
4.1
2.6
4.1
2.6
4.1
2.6
4.1
2.6
4.1
2.6
4.1
2.6
4.1
2.6
4.1
2.6
4.0
2.5
3.9
2.5
5.1
3.0
5.1
3.0
5.1
3.0
5.1
3.0
5.1
3.0
5.1
3.0
5.1
3.0
5.1
3.0
5.1
3.0
5.1
3.0
5.1
3.0
5.1
3.0
5.1
3.0
5.1
3.0
5.0
2.9
4.8
2.8
8
51
1-way Air Discharge Cassette Type ( MMU-AP****YH [007
unit
size
018
8
52
024
outdoor
air temp.
o
CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
o
14.0 CWB
o
20 CDB
TC
SHC
4.6
3.4
4.6
3.4
4.6
3.4
4.6
3.4
4.6
3.4
4.6
3.4
4.6
3.4
4.6
3.4
4.6
3.4
4.6
3.4
4.6
3.4
4.6
3.4
4.6
3.4
4.6
3.4
4.5
3.3
4.3
3.2
5.8
4.4
5.8
4.4
5.8
4.4
5.8
4.4
5.8
4.4
5.8
4.4
5.8
4.4
5.8
4.4
5.8
4.4
5.8
4.4
5.8
4.4
5.8
4.4
5.8
4.4
5.8
4.4
5.6
4.3
5.5
4.2
o
16.0 CWB
o
23 CDB
TC
SHC
5.1
3.6
5.1
3.6
5.1
3.6
5.1
3.6
5.1
3.6
5.1
3.6
5.1
3.6
5.1
3.6
5.1
3.6
5.1
3.6
5.1
3.6
5.1
3.6
5.1
3.6
5.1
3.6
4.9
3.5
4.8
3.4
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.2
4.6
6.1
4.4
012] , -AP****SH [015
TC : Total capacity [kW]
indoor air temp.
o
o
o
18.0 CWB
19.0 CWB
20.0 CWB
o
o
o
26 CDB
27 CDB
28 CDB
TC
SHC
TC
SHC
TC
SHC
5.4
3.8
5.6
3.8
5.8
3.8
5.4
3.8
5.6
3.8
5.8
3.8
5.4
3.8
5.6
3.8
5.8
3.8
5.4
3.8
5.6
3.8
5.8
3.8
5.4
3.8
5.6
3.8
5.8
3.8
5.4
3.8
5.6
3.8
5.8
3.8
5.4
3.8
5.6
3.8
5.8
3.8
5.4
3.8
5.6
3.8
5.8
3.8
5.4
3.8
5.6
3.8
5.8
3.8
5.4
3.8
5.6
3.8
5.8
3.8
5.4
3.8
5.6
3.8
5.8
3.8
5.4
3.8
5.6
3.8
5.8
3.8
5.4
3.8
5.6
3.8
5.8
3.8
5.4
3.8
5.6
3.8
5.8
3.8
5.3
3.7
5.4
3.7
5.6
3.7
5.1
3.6
5.3
3.6
5.4
3.6
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.7
4.9
6.9
4.8
7.1
4.8
6.5
4.7
6.7
4.7
6.9
4.7
024] )
SHC : Sensible capacity [kW]
o
22.0 CWB
o
30 CDB
TC
SHC
6.1
3.8
6.1
3.8
6.1
3.8
6.1
3.8
6.1
3.8
6.1
3.8
6.1
3.8
6.1
3.8
6.1
3.8
6.1
3.8
6.1
3.8
6.1
3.8
6.1
3.8
6.1
3.8
5.9
3.6
5.7
3.5
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.5
4.8
7.3
4.7
o
24.0 CWB
o
32 CDB
TC
SHC
6.4
3.7
6.4
3.7
6.4
3.7
6.4
3.7
6.4
3.7
6.4
3.7
6.4
3.7
6.4
3.7
6.4
3.7
6.4
3.7
6.4
3.7
6.4
3.7
6.4
3.7
6.4
3.7
6.2
3.6
6.0
3.5
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
7.8
4.7
7.6
4.6
Concealed Duct Standard Type ( MMD-AP****BH )
unit
size
007
009
012
015
outdoor
air temp.
o
CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
o
14.0 CWB
o
20 CDB
TC
SHC
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.7
1.5
1.7
1.4
2.3
1.9
2.3
1.9
2.3
1.9
2.3
1.9
2.3
1.9
2.3
1.9
2.3
1.9
2.3
1.9
2.3
1.9
2.3
1.9
2.3
1.9
2.3
1.9
2.3
1.9
2.3
1.9
2.2
1.8
2.2
1.8
3.0
2.2
3.0
2.2
3.0
2.2
3.0
2.2
3.0
2.2
3.0
2.2
3.0
2.2
3.0
2.2
3.0
2.2
3.0
2.2
3.0
2.2
3.0
2.2
3.0
2.2
3.0
2.2
2.9
2.1
2.8
2.1
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.6
2.6
3.5
2.5
o
16.0 CWB
o
23 CDB
TC
SHC
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
1.9
1.6
1.9
1.5
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
1.9
2.4
1.9
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.2
2.3
3.1
2.2
4.1
2.8
4.1
2.8
4.1
2.8
4.1
2.8
4.1
2.8
4.1
2.8
4.1
2.8
4.1
2.8
4.1
2.8
4.1
2.8
4.1
2.8
4.1
2.8
4.1
2.8
4.1
2.8
4.0
2.7
3.8
2.7
TC : Total capacity [kW]
indoor air temp.
o
o
o
18.0 CWB
19.0 CWB
20.0 CWB
o
o
o
26 CDB
27 CDB
28 CDB
TC
SHC
TC
SHC
TC
SHC
2.1
1.7
2.2
1.7
2.3
1.7
2.1
1.7
2.2
1.7
2.3
1.7
2.1
1.7
2.2
1.7
2.3
1.7
2.1
1.7
2.2
1.7
2.3
1.7
2.1
1.7
2.2
1.7
2.3
1.7
2.1
1.7
2.2
1.7
2.3
1.7
2.1
1.7
2.2
1.7
2.3
1.7
2.1
1.7
2.2
1.7
2.3
1.7
2.1
1.7
2.2
1.7
2.3
1.7
2.1
1.7
2.2
1.7
2.3
1.7
2.1
1.7
2.2
1.7
2.3
1.7
2.1
1.7
2.2
1.7
2.3
1.7
2.1
1.7
2.2
1.7
2.3
1.7
2.1
1.7
2.2
1.7
2.3
1.7
2.1
1.7
2.1
1.6
2.2
1.6
2.0
1.6
2.1
1.6
2.1
1.6
2.7
2.1
2.8
2.1
2.9
2.1
2.7
2.1
2.8
2.1
2.9
2.1
2.7
2.1
2.8
2.1
2.9
2.1
2.7
2.1
2.8
2.1
2.9
2.1
2.7
2.1
2.8
2.1
2.9
2.1
2.7
2.1
2.8
2.1
2.9
2.1
2.7
2.1
2.8
2.1
2.9
2.1
2.7
2.1
2.8
2.1
2.9
2.1
2.7
2.1
2.8
2.1
2.9
2.1
2.7
2.1
2.8
2.1
2.9
2.1
2.7
2.1
2.8
2.1
2.9
2.1
2.7
2.1
2.8
2.1
2.9
2.1
2.7
2.1
2.8
2.1
2.9
2.1
2.7
2.1
2.8
2.1
2.9
2.1
2.6
2.0
2.7
2.0
2.8
2.0
2.6
2.0
2.6
2.0
2.7
2.0
3.5
2.5
3.6
2.5
3.7
2.5
3.5
2.5
3.6
2.5
3.7
2.5
3.5
2.5
3.6
2.5
3.7
2.5
3.5
2.5
3.6
2.5
3.7
2.5
3.5
2.5
3.6
2.5
3.7
2.5
3.5
2.5
3.6
2.5
3.7
2.5
3.5
2.5
3.6
2.5
3.7
2.5
3.5
2.5
3.6
2.5
3.7
2.5
3.5
2.5
3.6
2.5
3.7
2.5
3.5
2.5
3.6
2.5
3.7
2.5
3.5
2.5
3.6
2.5
3.7
2.5
3.5
2.5
3.6
2.5
3.7
2.5
3.5
2.5
3.6
2.5
3.7
2.5
3.5
2.5
3.6
2.5
3.7
2.5
3.4
2.4
3.5
2.4
3.6
2.4
3.3
2.4
3.4
2.4
3.5
2.4
4.4
3.0
4.5
3.0
4.6
3.0
4.4
3.0
4.5
3.0
4.6
3.0
4.4
3.0
4.5
3.0
4.6
3.0
4.4
3.0
4.5
3.0
4.6
3.0
4.4
3.0
4.5
3.0
4.6
3.0
4.4
3.0
4.5
3.0
4.6
3.0
4.4
3.0
4.5
3.0
4.6
3.0
4.4
3.0
4.5
3.0
4.6
3.0
4.4
3.0
4.5
3.0
4.6
3.0
4.4
3.0
4.5
3.0
4.6
3.0
4.4
3.0
4.5
3.0
4.6
3.0
4.4
3.0
4.5
3.0
4.6
3.0
4.4
3.0
4.5
3.0
4.6
3.0
4.4
3.0
4.5
3.0
4.6
3.0
4.2
2.9
4.4
2.9
4.5
2.9
4.1
2.8
4.2
2.8
4.4
2.8
SHC : Sensible capacity [kW]
o
22.0 CWB
o
30 CDB
TC
SHC
2.4
1.7
2.4
1.7
2.4
1.7
2.4
1.7
2.4
1.7
2.4
1.7
2.4
1.7
2.4
1.7
2.4
1.7
2.4
1.7
2.4
1.7
2.4
1.7
2.4
1.7
2.4
1.7
2.3
1.6
2.3
1.6
3.1
2.1
3.1
2.1
3.1
2.1
3.1
2.1
3.1
2.1
3.1
2.1
3.1
2.1
3.1
2.1
3.1
2.1
3.1
2.1
3.1
2.1
3.1
2.1
3.1
2.1
3.1
2.1
3.0
2.0
2.9
2.0
3.9
2.5
3.9
2.5
3.9
2.5
3.9
2.5
3.9
2.5
3.9
2.5
3.9
2.5
3.9
2.5
3.9
2.5
3.9
2.5
3.9
2.5
3.9
2.5
3.9
2.5
3.9
2.5
3.8
2.4
3.7
2.3
4.9
3.0
4.9
3.0
4.9
3.0
4.9
3.0
4.9
3.0
4.9
3.0
4.9
3.0
4.9
3.0
4.9
3.0
4.9
3.0
4.9
3.0
4.9
3.0
4.9
3.0
4.9
3.0
4.7
2.9
4.6
2.8
o
24.0 CWB
o
32 CDB
TC
SHC
2.5
1.6
2.5
1.6
2.5
1.6
2.5
1.6
2.5
1.6
2.5
1.6
2.5
1.6
2.5
1.6
2.5
1.6
2.5
1.6
2.5
1.6
2.5
1.6
2.5
1.6
2.5
1.6
2.4
1.6
2.4
1.5
3.2
2.0
3.2
2.0
3.2
2.0
3.2
2.0
3.2
2.0
3.2
2.0
3.2
2.0
3.2
2.0
3.2
2.0
3.2
2.0
3.2
2.0
3.2
2.0
3.2
2.0
3.2
2.0
3.1
2.0
3.0
1.9
4.1
2.4
4.1
2.4
4.1
2.4
4.1
2.4
4.1
2.4
4.1
2.4
4.1
2.4
4.1
2.4
4.1
2.4
4.1
2.4
4.1
2.4
4.1
2.4
4.1
2.4
4.1
2.4
4.0
2.3
3.9
2.3
5.1
2.9
5.1
2.9
5.1
2.9
5.1
2.9
5.1
2.9
5.1
2.9
5.1
2.9
5.1
2.9
5.1
2.9
5.1
2.9
5.1
2.9
5.1
2.9
5.1
2.9
5.1
2.9
5.0
2.8
4.8
2.7
8
53
Concealed Duct Standard Type ( MMD-AP***BH )
unit
size
018
8
024
027
030
54
outdoor
air temp.
o
CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
o
14.0 CWB
o
20 CDB
TC
SHC
4.6
3.3
4.6
3.3
4.6
3.3
4.6
3.3
4.6
3.3
4.6
3.3
4.6
3.3
4.6
3.3
4.6
3.3
4.6
3.3
4.6
3.3
4.6
3.3
4.6
3.3
4.6
3.3
4.5
3.2
4.3
3.1
5.8
4.4
5.8
4.4
5.8
4.4
5.8
4.4
5.8
4.4
5.8
4.4
5.8
4.4
5.8
4.4
5.8
4.4
5.8
4.4
5.8
4.4
5.8
4.4
5.8
4.4
5.8
4.4
5.6
4.3
5.5
4.2
6.6
5.0
6.6
5.0
6.6
5.0
6.6
5.0
6.6
5.0
6.6
5.0
6.6
5.0
6.6
5.0
6.6
5.0
6.6
5.0
6.6
5.0
6.6
5.0
6.6
5.0
6.6
5.0
6.4
4.8
6.2
4.7
7.4
5.5
7.4
5.5
7.4
5.5
7.4
5.5
7.4
5.5
7.4
5.5
7.4
5.5
7.4
5.5
7.4
5.5
7.4
5.5
7.4
5.5
7.4
5.5
7.4
5.5
7.4
5.5
7.2
5.3
7.0
5.2
o
16.0 CWB
o
23 CDB
TC
SHC
5.1
3.5
5.1
3.5
5.1
3.5
5.1
3.5
5.1
3.5
5.1
3.5
5.1
3.5
5.1
3.5
5.1
3.5
5.1
3.5
5.1
3.5
5.1
3.5
5.1
3.5
5.1
3.5
4.9
3.4
4.8
3.3
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.2
4.6
6.1
4.4
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.0
5.1
6.8
5.0
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
7.9
5.7
7.7
5.5
TC : Total capacity [kW]
indoor air temp.
o
o
o
18.0 CWB
19.0 CWB
20.0 CWB
o
o
o
26 CDB
27 CDB
28 CDB
TC
SHC
TC
SHC
TC
SHC
5.4
3.7
5.6
3.7
5.8
3.7
5.4
3.7
5.6
3.7
5.8
3.7
5.4
3.7
5.6
3.7
5.8
3.7
5.4
3.7
5.6
3.7
5.8
3.7
5.4
3.7
5.6
3.7
5.8
3.7
5.4
3.7
5.6
3.7
5.8
3.7
5.4
3.7
5.6
3.7
5.8
3.7
5.4
3.7
5.6
3.7
5.8
3.7
5.4
3.7
5.6
3.7
5.8
3.7
5.4
3.7
5.6
3.7
5.8
3.7
5.4
3.7
5.6
3.7
5.8
3.7
5.4
3.7
5.6
3.7
5.8
3.7
5.4
3.7
5.6
3.7
5.8
3.7
5.4
3.7
5.6
3.7
5.8
3.7
5.3
3.6
5.4
3.6
5.6
3.6
5.1
3.5
5.3
3.5
5.4
3.5
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.7
4.9
6.9
4.8
7.1
4.8
6.5
4.7
6.7
4.7
6.9
4.7
7.8
5.6
8.0
5.6
8.2
5.6
7.8
5.6
8.0
5.6
8.2
5.6
7.8
5.6
8.0
5.6
8.2
5.6
7.8
5.6
8.0
5.6
8.2
5.6
7.8
5.6
8.0
5.6
8.2
5.6
7.8
5.6
8.0
5.6
8.2
5.6
7.8
5.6
8.0
5.6
8.2
5.6
7.8
5.6
8.0
5.6
8.2
5.6
7.8
5.6
8.0
5.6
8.2
5.6
7.8
5.6
8.0
5.6
8.2
5.6
7.8
5.6
8.0
5.6
8.2
5.6
7.8
5.6
8.0
5.6
8.2
5.6
7.8
5.6
8.0
5.6
8.2
5.6
7.8
5.6
8.0
5.6
8.2
5.6
7.5
5.4
7.7
5.4
8.0
5.4
7.3
5.3
7.5
5.3
7.8
5.3
8.7
6.2
9.0
6.2
9.3
6.2
8.7
6.2
9.0
6.2
9.3
6.2
8.7
6.2
9.0
6.2
9.3
6.2
8.7
6.2
9.0
6.2
9.3
6.2
8.7
6.2
9.0
6.2
9.3
6.2
8.7
6.2
9.0
6.2
9.3
6.2
8.7
6.2
9.0
6.2
9.3
6.2
8.7
6.2
9.0
6.2
9.3
6.2
8.7
6.2
9.0
6.2
9.3
6.2
8.7
6.2
9.0
6.2
9.3
6.2
8.7
6.2
9.0
6.2
9.3
6.2
8.7
6.2
9.0
6.2
9.3
6.2
8.7
6.2
9.0
6.2
9.3
6.2
8.7
6.2
9.0
6.2
9.3
6.2
8.5
6.0
8.7
6.0
9.0
6.0
8.2
5.9
8.5
5.8
8.7
5.8
SHC : Sensible capacity [kW]
o
22.0 CWB
o
30 CDB
TC
SHC
6.1
3.7
6.1
3.7
6.1
3.7
6.1
3.7
6.1
3.7
6.1
3.7
6.1
3.7
6.1
3.7
6.1
3.7
6.1
3.7
6.1
3.7
6.1
3.7
6.1
3.7
6.1
3.7
5.9
3.5
5.7
3.4
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.5
4.8
7.3
4.7
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.4
5.4
8.2
5.2
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.5
5.9
9.2
5.8
o
24.0 CWB
o
32 CDB
TC
SHC
6.4
3.6
6.4
3.6
6.4
3.6
6.4
3.6
6.4
3.6
6.4
3.6
6.4
3.6
6.4
3.6
6.4
3.6
6.4
3.6
6.4
3.6
6.4
3.6
6.4
3.6
6.4
3.6
6.2
3.5
6.0
3.4
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
7.8
4.7
7.6
4.6
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
8.8
5.2
8.6
5.1
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
9.9
5.8
9.7
5.6
Concealed Duct Standard Type ( MMD-AP***BH )
unit
size
036
048
056
outdoor
air temp.
o
CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
o
14.0 CWB
o
20 CDB
TC
SHC
9.2
6.5
9.2
6.5
9.2
6.5
9.2
6.5
9.2
6.5
9.2
6.5
9.2
6.5
9.2
6.5
9.2
6.5
9.2
6.5
9.2
6.5
9.2
6.5
9.2
6.5
9.2
6.5
8.9
6.3
8.7
6.1
11.5
8.2
11.5
8.2
11.5
8.2
11.5
8.2
11.5
8.2
11.5
8.2
11.5
8.2
11.5
8.2
11.5
8.2
11.5
8.2
11.5
8.2
11.5
8.2
11.5
8.2
11.5
8.2
11.1
7.9
10.8
7.7
13.1
9.6
13.1
9.6
13.1
9.6
13.1
9.6
13.1
9.6
13.1
9.6
13.1
9.6
13.1
9.6
13.1
9.6
13.1
9.6
13.1
9.6
13.1
9.6
13.1
9.6
13.1
9.6
12.7
9.3
12.4
9.0
o
16.0 CWB
o
23 CDB
TC
SHC
10.2
6.9
10.2
6.9
10.2
6.9
10.2
6.9
10.2
6.9
10.2
6.9
10.2
6.9
10.2
6.9
10.2
6.9
10.2
6.9
10.2
6.9
10.2
6.9
10.2
6.9
10.2
6.9
9.8
6.7
9.6
6.5
12.7
8.7
12.7
8.7
12.7
8.7
12.7
8.7
12.7
8.7
12.7
8.7
12.7
8.7
12.7
8.7
12.7
8.7
12.7
8.7
12.7
8.7
12.7
8.7
12.7
8.7
12.7
8.7
12.3
8.4
12.0
8.2
14.5
10.2
14.5
10.2
14.5
10.2
14.5
10.2
14.5
10.2
14.5
10.2
14.5
10.2
14.5
10.2
14.5
10.2
14.5
10.2
14.5
10.2
14.5
10.2
14.5
10.2
14.5
10.2
14.1
9.9
13.7
9.6
TC : Total capacity [kW]
indoor air temp.
o
o
o
18.0 CWB
19.0 CWB
20.0 CWB
o
o
o
26 CDB
27 CDB
28 CDB
TC
SHC
TC
SHC
TC
SHC
10.9
7.3
11.2
7.3
11.5
7.3
10.9
7.3
11.2
7.3
11.5
7.3
10.9
7.3
11.2
7.3
11.5
7.3
10.9
7.3
11.2
7.3
11.5
7.3
10.9
7.3
11.2
7.3
11.5
7.3
10.9
7.3
11.2
7.3
11.5
7.3
10.9
7.3
11.2
7.3
11.5
7.3
10.9
7.3
11.2
7.3
11.5
7.3
10.9
7.3
11.2
7.3
11.5
7.3
10.9
7.3
11.2
7.3
11.5
7.3
10.9
7.3
11.2
7.3
11.5
7.3
10.9
7.3
11.2
7.3
11.5
7.3
10.9
7.3
11.2
7.3
11.5
7.3
10.9
7.3
11.2
7.3
11.5
7.3
10.5
7.1
10.8
7.1
11.2
7.1
10.2
6.9
10.5
6.9
10.9
6.9
13.6
9.2
14.0
9.2
14.4
9.2
13.6
9.2
14.0
9.2
14.4
9.2
13.6
9.2
14.0
9.2
14.4
9.2
13.6
9.2
14.0
9.2
14.4
9.2
13.6
9.2
14.0
9.2
14.4
9.2
13.6
9.2
14.0
9.2
14.4
9.2
13.6
9.2
14.0
9.2
14.4
9.2
13.6
9.2
14.0
9.2
14.4
9.2
13.6
9.2
14.0
9.2
14.4
9.2
13.6
9.2
14.0
9.2
14.4
9.2
13.6
9.2
14.0
9.2
14.4
9.2
13.6
9.2
14.0
9.2
14.4
9.2
13.6
9.2
14.0
9.2
14.4
9.2
13.6
9.2
14.0
9.2
14.4
9.2
13.1
8.9
13.6
8.9
14.0
8.9
12.8
8.7
13.2
8.7
13.6
8.7
15.5
10.8
16.0
10.8
16.5
10.8
15.5
10.8
16.0
10.8
16.5
10.8
15.5
10.8
16.0
10.8
16.5
10.8
15.5
10.8
16.0
10.8
16.5
10.8
15.5
10.8
16.0
10.8
16.5
10.8
15.5
10.8
16.0
10.8
16.5
10.8
15.5
10.8
16.0
10.8
16.5
10.8
15.5
10.8
16.0
10.8
16.5
10.8
15.5
10.8
16.0
10.8
16.5
10.8
15.5
10.8
16.0
10.8
16.5
10.8
15.5
10.8
16.0
10.8
16.5
10.8
15.5
10.8
16.0
10.8
16.5
10.8
15.5
10.8
16.0
10.8
16.5
10.8
15.5
10.8
16.0
10.8
16.5
10.8
15.0
10.5
15.5
10.5
16.0
10.5
14.6
10.2
15.1
10.2
15.5
10.2
SHC : Sensible capacity [kW]
o
22.0 CWB
o
30 CDB
TC
SHC
12.2
7.2
12.2
7.2
12.2
7.2
12.2
7.2
12.2
7.2
12.2
7.2
12.2
7.2
12.2
7.2
12.2
7.2
12.2
7.2
12.2
7.2
12.2
7.2
12.2
7.2
12.2
7.2
11.8
7.0
11.5
6.8
15.3
9.1
15.3
9.1
15.3
9.1
15.3
9.1
15.3
9.1
15.3
9.1
15.3
9.1
15.3
9.1
15.3
9.1
15.3
9.1
15.3
9.1
15.3
9.1
15.3
9.1
15.3
9.1
14.8
8.8
14.4
8.6
17.4
10.7
17.4
10.7
17.4
10.7
17.4
10.7
17.4
10.7
17.4
10.7
17.4
10.7
17.4
10.7
17.4
10.7
17.4
10.7
17.4
10.7
17.4
10.7
17.4
10.7
17.4
10.7
16.9
10.4
16.4
10.1
o
24.0 CWB
o
32 CDB
TC
SHC
12.8
7.1
12.8
7.1
12.8
7.1
12.8
7.1
12.8
7.1
12.8
7.1
12.8
7.1
12.8
7.1
12.8
7.1
12.8
7.1
12.8
7.1
12.8
7.1
12.8
7.1
12.8
7.1
12.4
6.8
12.0
6.6
16.0
8.9
16.0
8.9
16.0
8.9
16.0
8.9
16.0
8.9
16.0
8.9
16.0
8.9
16.0
8.9
16.0
8.9
16.0
8.9
16.0
8.9
16.0
8.9
16.0
8.9
16.0
8.9
15.4
8.6
15.0
8.4
18.2
10.5
18.2
10.5
18.2
10.5
18.2
10.5
18.2
10.5
18.2
10.5
18.2
10.5
18.2
10.5
18.2
10.5
18.2
10.5
18.2
10.5
18.2
10.5
18.2
10.5
18.2
10.5
17.7
10.1
17.2
9.8
8
55
Concealed Duct High Static Pressure Type ( MMD-AP****H )
unit
size
018
8
024
027
036
56
outdoor
air temp.
o
CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
o
14.0 CWB
o
20 CDB
TC
SHC
4.6
3.6
4.6
3.6
4.6
3.6
4.6
3.6
4.6
3.6
4.6
3.6
4.6
3.6
4.6
3.6
4.6
3.6
4.6
3.6
4.6
3.6
4.6
3.6
4.6
3.6
4.6
3.6
4.5
3.5
4.3
3.4
5.8
4.4
5.8
4.4
5.8
4.4
5.8
4.4
5.8
4.4
5.8
4.4
5.8
4.4
5.8
4.4
5.8
4.4
5.8
4.4
5.8
4.4
5.8
4.4
5.8
4.4
5.8
4.4
5.6
4.3
5.5
4.2
6.6
4.8
6.6
4.8
6.6
4.8
6.6
4.8
6.6
4.8
6.6
4.8
6.6
4.8
6.6
4.8
6.6
4.8
6.6
4.8
6.6
4.8
6.6
4.8
6.6
4.8
6.6
4.8
6.4
4.6
6.2
4.5
9.2
6.9
9.2
6.9
9.2
6.9
9.2
6.9
9.2
6.9
9.2
6.9
9.2
6.9
9.2
6.9
9.2
6.9
9.2
6.9
9.2
6.9
9.2
6.9
9.2
6.9
9.2
6.9
8.9
6.7
8.7
6.5
o
16.0 CWB
o
23 CDB
TC
SHC
5.1
3.8
5.1
3.8
5.1
3.8
5.1
3.8
5.1
3.8
5.1
3.8
5.1
3.8
5.1
3.8
5.1
3.8
5.1
3.8
5.1
3.8
5.1
3.8
5.1
3.8
5.1
3.8
4.9
3.7
4.8
3.6
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.2
4.6
6.1
4.4
7.3
5.1
7.3
5.1
7.3
5.1
7.3
5.1
7.3
5.1
7.3
5.1
7.3
5.1
7.3
5.1
7.3
5.1
7.3
5.1
7.3
5.1
7.3
5.1
7.3
5.1
7.3
5.1
7.0
4.9
6.8
4.8
10.2
7.4
10.2
7.4
10.2
7.4
10.2
7.4
10.2
7.4
10.2
7.4
10.2
7.4
10.2
7.4
10.2
7.4
10.2
7.4
10.2
7.4
10.2
7.4
10.2
7.4
10.2
7.4
9.8
7.1
9.6
6.9
TC : Total capacity [kW]
indoor air temp.
o
o
o
18.0 CWB
19.0 CWB
20.0 CWB
o
o
o
26 CDB
27 CDB
28 CDB
TC
SHC
TC
SHC
TC
SHC
5.4
4.0
5.6
4.0
5.8
4.0
5.4
4.0
5.6
4.0
5.8
4.0
5.4
4.0
5.6
4.0
5.8
4.0
5.4
4.0
5.6
4.0
5.8
4.0
5.4
4.0
5.6
4.0
5.8
4.0
5.4
4.0
5.6
4.0
5.8
4.0
5.4
4.0
5.6
4.0
5.8
4.0
5.4
4.0
5.6
4.0
5.8
4.0
5.4
4.0
5.6
4.0
5.8
4.0
5.4
4.0
5.6
4.0
5.8
4.0
5.4
4.0
5.6
4.0
5.8
4.0
5.4
4.0
5.6
4.0
5.8
4.0
5.4
4.0
5.6
4.0
5.8
4.0
5.4
4.0
5.6
4.0
5.8
4.0
5.3
3.9
5.4
3.9
5.6
3.9
5.1
3.8
5.3
3.8
5.4
3.8
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.9
5.0
7.1
5.0
7.3
5.0
6.7
4.9
6.9
4.8
7.1
4.8
6.5
4.7
6.7
4.7
6.9
4.7
7.8
5.4
8.0
5.4
8.2
5.4
7.8
5.4
8.0
5.4
8.2
5.4
7.8
5.4
8.0
5.4
8.2
5.4
7.8
5.4
8.0
5.4
8.2
5.4
7.8
5.4
8.0
5.4
8.2
5.4
7.8
5.4
8.0
5.4
8.2
5.4
7.8
5.4
8.0
5.4
8.2
5.4
7.8
5.4
8.0
5.4
8.2
5.4
7.8
5.4
8.0
5.4
8.2
5.4
7.8
5.4
8.0
5.4
8.2
5.4
7.8
5.4
8.0
5.4
8.2
5.4
7.8
5.4
8.0
5.4
8.2
5.4
7.8
5.4
8.0
5.4
8.2
5.4
7.8
5.4
8.0
5.4
8.2
5.4
7.5
5.2
7.7
5.2
8.0
5.2
7.3
5.1
7.5
5.1
7.8
5.1
10.9
7.8
11.2
7.8
11.5
7.8
10.9
7.8
11.2
7.8
11.5
7.8
10.9
7.8
11.2
7.8
11.5
7.8
10.9
7.8
11.2
7.8
11.5
7.8
10.9
7.8
11.2
7.8
11.5
7.8
10.9
7.8
11.2
7.8
11.5
7.8
10.9
7.8
11.2
7.8
11.5
7.8
10.9
7.8
11.2
7.8
11.5
7.8
10.9
7.8
11.2
7.8
11.5
7.8
10.9
7.8
11.2
7.8
11.5
7.8
10.9
7.8
11.2
7.8
11.5
7.8
10.9
7.8
11.2
7.8
11.5
7.8
10.9
7.8
11.2
7.8
11.5
7.8
10.9
7.8
11.2
7.8
11.5
7.8
10.5
7.6
10.8
7.6
11.2
7.5
10.2
7.4
10.5
7.3
10.9
7.3
SHC : Sensible capacity [kW]
o
22.0 CWB
o
30 CDB
TC
SHC
6.1
4.0
6.1
4.0
6.1
4.0
6.1
4.0
6.1
4.0
6.1
4.0
6.1
4.0
6.1
4.0
6.1
4.0
6.1
4.0
6.1
4.0
6.1
4.0
6.1
4.0
6.1
4.0
5.9
3.9
5.7
3.8
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.5
4.8
7.3
4.7
8.7
5.3
8.7
5.3
8.7
5.3
8.7
5.3
8.7
5.3
8.7
5.3
8.7
5.3
8.7
5.3
8.7
5.3
8.7
5.3
8.7
5.3
8.7
5.3
8.7
5.3
8.7
5.3
8.4
5.2
8.2
5.0
12.2
7.7
12.2
7.7
12.2
7.7
12.2
7.7
12.2
7.7
12.2
7.7
12.2
7.7
12.2
7.7
12.2
7.7
12.2
7.7
12.2
7.7
12.2
7.7
12.2
7.7
12.2
7.7
11.8
7.5
11.5
7.3
o
24.0 CWB
o
32 CDB
TC
SHC
6.4
3.9
6.4
3.9
6.4
3.9
6.4
3.9
6.4
3.9
6.4
3.9
6.4
3.9
6.4
3.9
6.4
3.9
6.4
3.9
6.4
3.9
6.4
3.9
6.4
3.9
6.4
3.9
6.2
3.8
6.0
3.7
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
7.8
4.7
7.6
4.6
9.1
5.2
9.1
5.2
9.1
5.2
9.1
5.2
9.1
5.2
9.1
5.2
9.1
5.2
9.1
5.2
9.1
5.2
9.1
5.2
9.1
5.2
9.1
5.2
9.1
5.2
9.1
5.2
8.8
5.1
8.6
4.9
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.4
7.3
12.0
7.1
Concealed Duct High Static Pressure Type ( MMD-AP****H )
unit
size
048
072
096
outdoor
air temp.
o
CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
o
14.0 CWB
o
20 CDB
TC
SHC
11.5
8.4
11.5
8.4
11.5
8.4
11.5
8.4
11.5
8.4
11.5
8.4
11.5
8.4
11.5
8.4
11.5
8.4
11.5
8.4
11.5
8.4
11.5
8.4
11.5
8.4
11.5
8.4
11.1
8.2
10.8
7.9
18.4
13.2
18.4
13.2
18.4
13.2
18.4
13.2
18.4
13.2
18.4
13.2
18.4
13.2
18.4
13.2
18.4
13.2
18.4
13.2
18.4
13.2
18.4
13.2
18.4
13.2
18.4
13.2
17.8
12.8
17.3
12.4
23.0
16.2
23.0
16.2
23.0
16.2
23.0
16.2
23.0
16.2
23.0
16.2
23.0
16.2
23.0
16.2
23.0
16.2
23.0
16.2
23.0
16.2
23.0
16.2
23.0
16.2
23.0
16.2
22.3
15.7
21.6
15.3
o
16.0 CWB
o
23 CDB
TC
SHC
12.7
9.0
12.7
9.0
12.7
9.0
12.7
9.0
12.7
9.0
12.7
9.0
12.7
9.0
12.7
9.0
12.7
9.0
12.7
9.0
12.7
9.0
12.7
9.0
12.7
9.0
12.7
9.0
12.3
8.7
12.0
8.4
20.3
14.1
20.3
14.1
20.3
14.1
20.3
14.1
20.3
14.1
20.3
14.1
20.3
14.1
20.3
14.1
20.3
14.1
20.3
14.1
20.3
14.1
20.3
14.1
20.3
14.1
20.3
14.1
19.7
13.6
19.1
13.2
25.4
17.3
25.4
17.3
25.4
17.3
25.4
17.3
25.4
17.3
25.4
17.3
25.4
17.3
25.4
17.3
25.4
17.3
25.4
17.3
25.4
17.3
25.4
17.3
25.4
17.3
25.4
17.3
24.6
16.7
23.9
16.3
TC : Total capacity [kW]
indoor air temp.
o
o
o
18.0 CWB
19.0 CWB
20.0 CWB
o
o
o
26 CDB
27 CDB
28 CDB
TC
SHC
TC
SHC
TC
SHC
13.6
9.5
14.0
9.5
14.4
9.5
13.6
9.5
14.0
9.5
14.4
9.5
13.6
9.5
14.0
9.5
14.4
9.5
13.6
9.5
14.0
9.5
14.4
9.5
13.6
9.5
14.0
9.5
14.4
9.5
13.6
9.5
14.0
9.5
14.4
9.5
13.6
9.5
14.0
9.5
14.4
9.5
13.6
9.5
14.0
9.5
14.4
9.5
13.6
9.5
14.0
9.5
14.4
9.5
13.6
9.5
14.0
9.5
14.4
9.5
13.6
9.5
14.0
9.5
14.4
9.5
13.6
9.5
14.0
9.5
14.4
9.5
13.6
9.5
14.0
9.5
14.4
9.5
13.6
9.5
14.0
9.5
14.4
9.5
13.1
9.2
13.6
9.2
14.0
9.2
12.8
9.0
13.2
8.9
13.6
8.9
21.7
14.9
22.4
14.9
23.1
14.9
21.7
14.9
22.4
14.9
23.1
14.9
21.7
14.9
22.4
14.9
23.1
14.9
21.7
14.9
22.4
14.9
23.1
14.9
21.7
14.9
22.4
14.9
23.1
14.9
21.7
14.9
22.4
14.9
23.1
14.9
21.7
14.9
22.4
14.9
23.1
14.9
21.7
14.9
22.4
14.9
23.1
14.9
21.7
14.9
22.4
14.9
23.1
14.9
21.7
14.9
22.4
14.9
23.1
14.9
21.7
14.9
22.4
14.9
23.1
14.9
21.7
14.9
22.4
14.9
23.1
14.9
21.7
14.9
22.4
14.9
23.1
14.9
21.7
14.9
22.4
14.9
23.1
14.9
21.0
14.5
21.7
14.4
22.3
14.4
20.4
14.1
21.1
14.0
21.7
14.0
27.2
18.4
28.0
18.3
28.8
18.3
27.2
18.4
28.0
18.3
28.8
18.3
27.2
18.4
28.0
18.3
28.8
18.3
27.2
18.4
28.0
18.3
28.8
18.3
27.2
18.4
28.0
18.3
28.8
18.3
27.2
18.4
28.0
18.3
28.8
18.3
27.2
18.4
28.0
18.3
28.8
18.3
27.2
18.4
28.0
18.3
28.8
18.3
27.2
18.4
28.0
18.3
28.8
18.3
27.2
18.4
28.0
18.3
28.8
18.3
27.2
18.4
28.0
18.3
28.8
18.3
27.2
18.4
28.0
18.3
28.8
18.3
27.2
18.4
28.0
18.3
28.8
18.3
27.2
18.4
28.0
18.3
28.8
18.3
26.3
17.8
18.3
17.7
27.9
17.7
25.6
17.3
26.3
17.2
27.1
17.2
SHC : Sensible capacity [kW]
o
22.0 CWB
o
30 CDB
TC
SHC
15.3
9.4
15.3
9.4
15.3
9.4
15.3
9.4
15.3
9.4
15.3
9.4
15.3
9.4
15.3
9.4
15.3
9.4
15.3
9.4
15.3
9.4
15.3
9.4
15.3
9.4
15.3
9.4
14.8
9.1
14.4
8.9
24.4
14.8
24.4
14.8
24.4
14.8
24.4
14.8
24.4
14.8
24.4
14.8
24.4
14.8
24.4
14.8
24.4
14.8
24.4
14.8
24.4
14.8
24.4
14.8
24.4
14.8
24.4
14.8
23.6
14.3
23.0
13.9
30.5
18.1
30.5
18.1
30.5
18.1
30.5
18.1
30.5
18.1
30.5
18.1
30.5
18.1
30.5
18.1
30.5
18.1
30.5
18.1
30.5
18.1
30.5
18.1
30.5
18.1
30.5
18.1
29.5
17.6
28.7
17.1
o
24.0 CWB
o
32 CDB
TC
SHC
16.0
9.2
16.0
9.2
16.0
9.2
16.0
9.2
16.0
9.2
16.0
9.2
16.0
9.2
16.0
9.2
16.0
9.2
16.0
9.2
16.0
9.2
16.0
9.2
16.0
9.2
16.0
9.2
15.4
8.9
15.0
8.7
25.5
14.4
25.5
14.4
25.5
14.4
25.5
14.4
25.5
14.4
25.5
14.4
25.5
14.4
25.5
14.4
25.5
14.4
25.5
14.4
25.5
14.4
25.5
14.4
25.5
14.4
25.5
14.4
24.7
14.0
24.0
13.6
31.9
17.7
31.9
17.7
31.9
17.7
31.9
17.7
31.9
17.7
31.9
17.7
31.9
17.7
31.9
17.7
31.9
17.7
31.9
17.7
31.9
17.7
31.9
17.7
31.9
17.7
31.9
17.7
30.9
17.1
30.0
16.7
8
57
Under Ceiling Type ( MMC-AP****H )
unit
size
015
8
018
024
027
58
outdoor
air temp.
o
CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
o
14.0 CWB
o
20 CDB
TC
SHC
3.7
2.8
3.7
2.8
3.7
2.8
3.7
2.8
3.7
2.8
3.7
2.8
3.7
2.8
3.7
2.8
3.7
2.8
3.7
2.8
3.7
2.8
3.7
2.8
3.7
2.8
3.7
2.8
3.6
2.7
3.5
2.7
4.6
3.5
4.6
3.5
4.6
3.5
4.6
3.5
4.6
3.5
4.6
3.5
4.6
3.5
4.6
3.5
4.6
3.5
4.6
3.5
4.6
3.5
4.6
3.5
4.6
3.5
4.6
3.5
4.5
3.3
4.3
3.3
5.8
4.5
5.8
4.5
5.8
4.5
5.8
4.5
5.8
4.5
5.8
4.5
5.8
4.5
5.8
4.5
5.8
4.5
5.8
4.5
5.8
4.5
5.8
4.5
5.8
4.5
5.8
4.5
5.6
4.4
5.5
4.3
6.6
5.0
6.6
5.0
6.6
5.0
6.6
5.0
6.6
5.0
6.6
5.0
6.6
5.0
6.6
5.0
6.6
5.0
6.6
5.0
6.6
5.0
6.6
5.0
6.6
5.0
6.6
5.0
6.4
4.8
6.2
4.7
o
16.0 CWB
o
23 CDB
TC
SHC
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.0
2.9
3.8
2.8
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
4.9
3.6
4.8
3.5
6.4
4.8
6.4
4.8
6.4
4.8
6.4
4.8
6.4
4.8
6.4
4.8
6.4
4.8
6.4
4.8
6.4
4.8
6.4
4.8
6.4
4.8
6.4
4.8
6.4
4.8
6.4
4.8
6.2
4.7
6.1
4.5
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.0
5.1
6.8
5.0
TC : Total capacity [kW]
indoor air temp.
o
o
o
18.0 CWB
19.0 CWB
20.0 CWB
o
o
o
26 CDB
27 CDB
28 CDB
TC
SHC
TC
SHC
TC
SHC
4.4
3.2
4.5
3.2
4.6
3.2
4.4
3.2
4.5
3.2
4.6
3.2
4.4
3.2
4.5
3.2
4.6
3.2
4.4
3.2
4.5
3.2
4.6
3.2
4.4
3.2
4.5
3.2
4.6
3.2
4.4
3.2
4.5
3.2
4.6
3.2
4.4
3.2
4.5
3.2
4.6
3.2
4.4
3.2
4.5
3.2
4.6
3.2
4.4
3.2
4.5
3.2
4.6
3.2
4.4
3.2
4.5
3.2
4.6
3.2
4.4
3.2
4.5
3.2
4.6
3.2
4.4
3.2
4.5
3.2
4.6
3.2
4.4
3.2
4.5
3.2
4.6
3.2
4.4
3.2
4.5
3.2
4.6
3.2
4.2
3.1
4.4
3.1
4.5
3.1
4.1
3.0
4.2
3.0
4.4
3.0
5.4
3.9
5.6
3.9
5.8
3.9
5.4
3.9
5.6
3.9
5.8
3.9
5.4
3.9
5.6
3.9
5.8
3.9
5.4
3.9
5.6
3.9
5.8
3.9
5.4
3.9
5.6
3.9
5.8
3.9
5.4
3.9
5.6
3.9
5.8
3.9
5.4
3.9
5.6
3.9
5.8
3.9
5.4
3.9
5.6
3.9
5.8
3.9
5.4
3.9
5.6
3.9
5.8
3.9
5.4
3.9
5.6
3.9
5.8
3.9
5.4
3.9
5.6
3.9
5.8
3.9
5.4
3.9
5.6
3.9
5.8
3.9
5.4
3.9
5.6
3.9
5.8
3.9
5.4
3.9
5.6
3.9
5.8
3.9
5.3
3.8
5.4
3.8
5.6
3.8
5.1
3.7
5.3
3.7
5.4
3.7
6.9
5.1
7.1
5.1
7.3
5.1
6.9
5.1
7.1
5.1
7.3
5.1
6.9
5.1
7.1
5.1
7.3
5.1
6.9
5.1
7.1
5.1
7.3
5.1
6.9
5.1
7.1
5.1
7.3
5.1
6.9
5.1
7.1
5.1
7.3
5.1
6.9
5.1
7.1
5.1
7.3
5.1
6.9
5.1
7.1
5.1
7.3
5.1
6.9
5.1
7.1
5.1
7.3
5.1
6.9
5.1
7.1
5.1
7.3
5.1
6.9
5.1
7.1
5.1
7.3
5.1
6.9
5.1
7.1
5.1
7.3
5.1
6.9
5.1
7.1
5.1
7.3
5.1
6.9
5.1
7.1
5.1
7.3
5.1
6.7
5.0
6.9
4.9
7.1
4.9
6.5
4.8
6.7
4.8
6.9
4.8
7.8
5.6
8.0
5.6
8.2
5.6
7.8
5.6
8.0
5.6
8.2
5.6
7.8
5.6
8.0
5.6
8.2
5.6
7.8
5.6
8.0
5.6
8.2
5.6
7.8
5.6
8.0
5.6
8.2
5.6
7.8
5.6
8.0
5.6
8.2
5.6
7.8
5.6
8.0
5.6
8.2
5.6
7.8
5.6
8.0
5.6
8.2
5.6
7.8
5.6
8.0
5.6
8.2
5.6
7.8
5.6
8.0
5.6
8.2
5.6
7.8
5.6
8.0
5.6
8.2
5.6
7.8
5.6
8.0
5.6
8.2
5.6
7.8
5.6
8.0
5.6
8.2
5.6
7.8
5.6
8.0
5.6
8.2
5.6
7.5
5.4
7.7
5.4
8.0
5.4
7.3
5.3
7.5
5.3
7.8
5.3
SHC : Sensible capacity [kW]
o
22.0 CWB
o
30 CDB
TC
SHC
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.7
3.1
4.6
3.0
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
5.9
3.7
5.7
3.6
7.7
5.1
7.7
5.1
7.7
5.1
7.7
5.1
7.7
5.1
7.7
5.1
7.7
5.1
7.7
5.1
7.7
5.1
7.7
5.1
7.7
5.1
7.7
5.1
7.7
5.1
7.7
5.1
7.5
4.9
7.3
4.8
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.4
5.4
8.2
5.2
o
24.0 CWB
o
32 CDB
TC
SHC
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.0
3.0
4.8
2.9
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.2
3.7
6.0
3.6
8.1
4.9
8.1
4.9
8.1
4.9
8.1
4.9
8.1
4.9
8.1
4.9
8.1
4.9
8.1
4.9
8.1
4.9
8.1
4.9
8.1
4.9
8.1
4.9
8.1
4.9
8.1
4.9
7.8
4.8
7.6
4.6
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
8.8
5.2
8.6
5.1
Under Ceiling Type ( MMC-AP****H )
unit
size
036
048
outdoor
air temp.
o
CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
o
14.0 CWB
o
20 CDB
TC
SHC
9.2
6.7
9.2
6.7
9.2
6.7
9.2
6.7
9.2
6.7
9.2
6.7
9.2
6.7
9.2
6.7
9.2
6.7
9.2
6.7
9.2
6.7
9.2
6.7
9.2
6.7
9.2
6.7
8.9
6.5
8.7
6.3
11.5
8.7
11.5
8.7
11.5
8.7
11.5
8.7
11.5
8.7
11.5
8.7
11.5
8.7
11.5
8.7
11.5
8.7
11.5
8.7
11.5
8.7
11.5
8.7
11.5
8.7
11.5
8.7
11.1
8.4
10.8
8.2
o
16.0 CWB
o
23 CDB
TC
SHC
10.2
7.2
10.2
7.2
10.2
7.2
10.2
7.2
10.2
7.2
10.2
7.2
10.2
7.2
10.2
7.2
10.2
7.2
10.2
7.2
10.2
7.2
10.2
7.2
10.2
7.2
10.2
7.2
9.8
6.9
9.6
6.8
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.3
9.0
12.0
8.7
TC : Total capacity [kW]
indoor air temp.
o
o
o
18.0 CWB
19.0 CWB
20.0 CWB
o
o
o
26 CDB
27 CDB
28 CDB
TC
SHC
TC
SHC
TC
SHC
10.9
7.6
11.2
7.6
11.5
7.6
10.9
7.6
11.2
7.6
11.5
7.6
10.9
7.6
11.2
7.6
11.5
7.6
10.9
7.6
11.2
7.6
11.5
7.6
10.9
7.6
11.2
7.6
11.5
7.6
10.9
7.6
11.2
7.6
11.5
7.6
10.9
7.6
11.2
7.6
11.5
7.6
10.9
7.6
11.2
7.6
11.5
7.6
10.9
7.6
11.2
7.6
11.5
7.6
10.9
7.6
11.2
7.6
11.5
7.6
10.9
7.6
11.2
7.6
11.5
7.6
10.9
7.6
11.2
7.6
11.5
7.6
10.9
7.6
11.2
7.6
11.5
7.6
10.9
7.6
11.2
7.6
11.5
7.6
10.5
7.4
10.8
7.4
11.2
7.4
10.2
7.2
10.5
7.2
10.9
7.2
13.6
9.8
14.0
9.8
14.4
9.8
13.6
9.8
14.0
9.8
14.4
9.8
13.6
9.8
14.0
9.8
14.4
9.8
13.6
9.8
14.0
9.8
14.4
9.8
13.6
9.8
14.0
9.8
14.4
9.8
13.6
9.8
14.0
9.8
14.4
9.8
13.6
9.8
14.0
9.8
14.4
9.8
13.6
9.8
14.0
9.8
14.4
9.8
13.6
9.8
14.0
9.8
14.4
9.8
13.6
9.8
14.0
9.8
14.4
9.8
13.6
9.8
14.0
9.8
14.4
9.8
13.6
9.8
14.0
9.8
14.4
9.8
13.6
9.8
14.0
9.8
14.4
9.8
13.6
9.8
14.0
9.8
14.4
9.8
13.1
9.5
13.6
9.5
14.0
9.5
12.8
9.2
13.2
9.2
13.6
9.2
SHC : Sensible capacity [kW]
o
22.0 CWB
o
30 CDB
TC
SHC
12.2
7.5
12.2
7.5
12.2
7.5
12.2
7.5
12.2
7.5
12.2
7.5
12.2
7.5
12.2
7.5
12.2
7.5
12.2
7.5
12.2
7.5
12.2
7.5
12.2
7.5
12.2
7.5
11.8
7.3
11.5
7.1
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
14.8
9.4
14.4
9.1
o
24.0 CWB
o
32 CDB
TC
SHC
12.8
7.4
12.8
7.4
12.8
7.4
12.8
7.4
12.8
7.4
12.8
7.4
12.8
7.4
12.8
7.4
12.8
7.4
12.8
7.4
12.8
7.4
12.8
7.4
12.8
7.4
12.8
7.4
12.4
7.1
12.0
6.9
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
15.4
9.2
15.0
8.9
8
59
High Wall Type ( MMK-AP****H )
unit
size
007
8
009
012
015
60
outdoor
air temp.
o
CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
o
14.0 CWB
o
20 CDB
TC
SHC
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.7
1.5
1.7
1.4
2.3
1.8
2.3
1.8
2.3
1.8
2.3
1.8
2.3
1.8
2.3
1.8
2.3
1.8
2.3
1.8
2.3
1.8
2.3
1.8
2.3
1.8
2.3
1.8
2.3
1.8
2.3
1.8
2.2
1.7
2.2
1.7
3.0
2.2
3.0
2.2
3.0
2.2
3.0
2.2
3.0
2.2
3.0
2.2
3.0
2.2
3.0
2.2
3.0
2.2
3.0
2.2
3.0
2.2
3.0
2.2
3.0
2.2
3.0
2.2
2.9
2.1
2.8
2.1
3.7
2.6
3.7
2.6
3.7
2.6
3.7
2.6
3.7
2.6
3.7
2.6
3.7
2.6
3.7
2.6
3.7
2.6
3.7
2.6
3.7
2.6
3.7
2.6
3.7
2.6
3.7
2.6
3.6
2.5
3.5
2.4
o
16.0 CWB
o
23 CDB
TC
SHC
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
1.9
1.6
1.9
1.5
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.8
2.4
1.8
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.2
2.3
3.1
2.2
4.1
2.7
4.1
2.7
4.1
2.7
4.1
2.7
4.1
2.7
4.1
2.7
4.1
2.7
4.1
2.7
4.1
2.7
4.1
2.7
4.1
2.7
4.1
2.7
4.1
2.7
4.1
2.7
4.0
2.6
3.8
2.6
TC : Total capacity [kW]
indoor air temp.
o
o
o
18.0 CWB
19.0 CWB
20.0 CWB
o
o
o
26 CDB
27 CDB
28 CDB
TC
SHC
TC
SHC
TC
SHC
2.1
1.7
2.2
1.7
2.3
1.7
2.1
1.7
2.2
1.7
2.3
1.7
2.1
1.7
2.2
1.7
2.3
1.7
2.1
1.7
2.2
1.7
2.3
1.7
2.1
1.7
2.2
1.7
2.3
1.7
2.1
1.7
2.2
1.7
2.3
1.7
2.1
1.7
2.2
1.7
2.3
1.7
2.1
1.7
2.2
1.7
2.3
1.7
2.1
1.7
2.2
1.7
2.3
1.7
2.1
1.7
2.2
1.7
2.3
1.7
2.1
1.7
2.2
1.7
2.3
1.7
2.1
1.7
2.2
1.7
2.3
1.7
2.1
1.7
2.2
1.7
2.3
1.7
2.1
1.7
2.2
1.7
2.3
1.7
2.1
1.7
2.1
1.6
2.2
1.6
2.0
1.6
2.1
1.6
2.1
1.6
2.7
2.0
2.8
2.0
2.9
2.0
2.7
2.0
2.8
2.0
2.9
2.0
2.7
2.0
2.8
2.0
2.9
2.0
2.7
2.0
2.8
2.0
2.9
2.0
2.7
2.0
2.8
2.0
2.9
2.0
2.7
2.0
2.8
2.0
2.9
2.0
2.7
2.0
2.8
2.0
2.9
2.0
2.7
2.0
2.8
2.0
2.9
2.0
2.7
2.0
2.8
2.0
2.9
2.0
2.7
2.0
2.8
2.0
2.9
2.0
2.7
2.0
2.8
2.0
2.9
2.0
2.7
2.0
2.8
2.0
2.9
2.0
2.7
2.0
2.8
2.0
2.9
2.0
2.7
2.0
2.8
2.0
2.9
2.0
2.6
1.9
2.7
1.9
2.8
1.9
2.6
1.9
2.6
1.9
2.7
1.9
3.5
2.5
3.6
2.5
3.7
2.5
3.5
2.5
3.6
2.5
3.7
2.5
3.5
2.5
3.6
2.5
3.7
2.5
3.5
2.5
3.6
2.5
3.7
2.5
3.5
2.5
3.6
2.5
3.7
2.5
3.5
2.5
3.6
2.5
3.7
2.5
3.5
2.5
3.6
2.5
3.7
2.5
3.5
2.5
3.6
2.5
3.7
2.5
3.5
2.5
3.6
2.5
3.7
2.5
3.5
2.5
3.6
2.5
3.7
2.5
3.5
2.5
3.6
2.5
3.7
2.5
3.5
2.5
3.6
2.5
3.7
2.5
3.5
2.5
3.6
2.5
3.7
2.5
3.5
2.5
3.6
2.5
3.7
2.5
3.4
2.4
3.5
2.4
3.6
2.4
3.3
2.4
3.4
2.4
3.5
2.4
4.4
2.9
4.5
2.9
4.6
2.9
4.4
2.9
4.5
2.9
4.6
2.9
4.4
2.9
4.5
2.9
4.6
2.9
4.4
2.9
4.5
2.9
4.6
2.9
4.4
2.9
4.5
2.9
4.6
2.9
4.4
2.9
4.5
2.9
4.6
2.9
4.4
2.9
4.5
2.9
4.6
2.9
4.4
2.9
4.5
2.9
4.6
2.9
4.4
2.9
4.5
2.9
4.6
2.9
4.4
2.9
4.5
2.9
4.6
2.9
4.4
2.9
4.5
2.9
4.6
2.9
4.4
2.9
4.5
2.9
4.6
2.9
4.4
2.9
4.5
2.9
4.6
2.9
4.4
2.9
4.5
2.9
4.6
2.9
4.2
2.8
4.4
2.8
4.5
2.8
4.1
2.7
4.2
2.7
4.4
2.7
SHC : Sensible capacity [kW]
o
22.0 CWB
o
30 CDB
TC
SHC
2.4
1.7
2.4
1.7
2.4
1.7
2.4
1.7
2.4
1.7
2.4
1.7
2.4
1.7
2.4
1.7
2.4
1.7
2.4
1.7
2.4
1.7
2.4
1.7
2.4
1.7
2.4
1.7
2.3
1.6
2.3
1.6
3.1
2.0
3.1
2.0
3.1
2.0
3.1
2.0
3.1
2.0
3.1
2.0
3.1
2.0
3.1
2.0
3.1
2.0
3.1
2.0
3.1
2.0
3.1
2.0
3.1
2.0
3.1
2.0
3.0
1.9
2.9
1.9
3.9
2.5
3.9
2.5
3.9
2.5
3.9
2.5
3.9
2.5
3.9
2.5
3.9
2.5
3.9
2.5
3.9
2.5
3.9
2.5
3.9
2.5
3.9
2.5
3.9
2.5
3.9
2.5
3.8
2.4
3.7
2.3
4.9
2.9
4.9
2.9
4.9
2.9
4.9
2.9
4.9
2.9
4.9
2.9
4.9
2.9
4.9
2.9
4.9
2.9
4.9
2.9
4.9
2.9
4.9
2.9
4.9
2.9
4.9
2.9
4.7
2.8
4.6
2.7
o
24.0 CWB
o
32 CDB
TC
SHC
2.5
1.6
2.5
1.6
2.5
1.6
2.5
1.6
2.5
1.6
2.5
1.6
2.5
1.6
2.5
1.6
2.5
1.6
2.5
1.6
2.5
1.6
2.5
1.6
2.5
1.6
2.5
1.6
2.4
1.6
2.4
1.5
3.2
1.9
3.2
1.9
3.2
1.9
3.2
1.9
3.2
1.9
3.2
1.9
3.2
1.9
3.2
1.9
3.2
1.9
3.2
1.9
3.2
1.9
3.2
1.9
3.2
1.9
3.2
1.9
3.1
1.9
3.0
1.8
4.1
2.4
4.1
2.4
4.1
2.4
4.1
2.4
4.1
2.4
4.1
2.4
4.1
2.4
4.1
2.4
4.1
2.4
4.1
2.4
4.1
2.4
4.1
2.4
4.1
2.4
4.1
2.4
4.0
2.3
3.9
2.3
5.1
2.8
5.1
2.8
5.1
2.8
5.1
2.8
5.1
2.8
5.1
2.8
5.1
2.8
5.1
2.8
5.1
2.8
5.1
2.8
5.1
2.8
5.1
2.8
5.1
2.8
5.1
2.8
5.0
2.7
4.8
2.6
High Wall Type ( MMK-AP****H )
unit
size
018
024
outdoor
air temp.
o
C DB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
o
14.0 CWB
o
20 CDB
TC
SHC
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.5
3.1
4.3
3.0
5.8
4.2
5.8
4.2
5.8
4.2
5.8
4.2
5.8
4.2
5.8
4.2
5.8
4.2
5.8
4.2
5.8
4.2
5.8
4.2
5.8
4.2
5.8
4.2
5.8
4.2
5.8
4.2
5.6
4.0
5.5
3.9
o
16.0 CWB
o
23 CDB
TC
SHC
5.1
3.4
5.1
3.4
5.1
3.4
5.1
3.4
5.1
3.4
5.1
3.4
5.1
3.4
5.1
3.4
5.1
3.4
5.1
3.4
5.1
3.4
5.1
3.4
5.1
3.4
5.1
3.4
4.9
3.3
4.8
3.2
6.4
4.4
6.4
4.4
6.4
4.4
6.4
4.4
6.4
4.4
6.4
4.4
6.4
4.4
6.4
4.4
6.4
4.4
6.4
4.4
6.4
4.4
6.4
4.4
6.4
4.4
6.4
4.4
6.2
4.3
6.1
4.2
TC : Total
indoor air temp.
o
o
18.0 CWB
19.0 CWB
o
o
26 CDB
27 CDB
TC
SHC
TC
SHC
5.4
3.6
5.6
3.6
5.4
3.6
5.6
3.6
5.4
3.6
5.6
3.6
5.4
3.6
5.6
3.6
5.4
3.6
5.6
3.6
5.4
3.6
5.6
3.6
5.4
3.6
5.6
3.6
5.4
3.6
5.6
3.6
5.4
3.6
5.6
3.6
5.4
3.6
5.6
3.6
5.4
3.6
5.6
3.6
5.4
3.6
5.6
3.6
5.4
3.6
5.6
3.6
5.4
3.6
5.6
3.6
5.3
3.5
5.4
3.5
5.1
3.4
5.3
3.4
6.9
4.7
7.1
4.7
6.9
4.7
7.1
4.7
6.9
4.7
7.1
4.7
6.9
4.7
7.1
4.7
6.9
4.7
7.1
4.7
6.9
4.7
7.1
4.7
6.9
4.7
7.1
4.7
6.9
4.7
7.1
4.7
6.9
4.7
7.1
4.7
6.9
4.7
7.1
4.7
6.9
4.7
7.1
4.7
6.9
4.7
7.1
4.7
6.9
4.7
7.1
4.7
6.9
4.7
7.1
4.7
6.7
4.6
6.9
4.5
6.5
4.4
6.7
4.4
capacity [kW]
o
20.0 CWB
o
28 CDB
TC
SHC
5.8
3.6
5.8
3.6
5.8
3.6
5.8
3.6
5.8
3.6
5.8
3.6
5.8
3.6
5.8
3.6
5.8
3.6
5.8
3.6
5.8
3.6
5.8
3.6
5.8
3.6
5.8
3.6
5.6
3.5
5.4
3.4
7.3
4.7
7.3
4.7
7.3
4.7
7.3
4.7
7.3
4.7
7.3
4.7
7.3
4.7
7.3
4.7
7.3
4.7
7.3
4.7
7.3
4.7
7.3
4.7
7.3
4.7
7.3
4.7
7.1
4.5
6.9
4.4
SHC : Sensible capacity [kW]
o
22.0 CWB
o
30 CDB
TC
SHC
6.1
3.6
6.1
3.6
6.1
3.6
6.1
3.6
6.1
3.6
6.1
3.6
6.1
3.6
6.1
3.6
6.1
3.6
6.1
3.6
6.1
3.6
6.1
3.6
6.1
3.6
6.1
3.6
5.9
3.5
5.7
3.4
7.7
4.7
7.7
4.7
7.7
4.7
7.7
4.7
7.7
4.7
7.7
4.7
7.7
4.7
7.7
4.7
7.7
4.7
7.7
4.7
7.7
4.7
7.7
4.7
7.7
4.7
7.7
4.7
7.5
4.5
7.3
4.4
o
24.0 CWB
o
32 CDB
TC
SHC
6.4
3.5
6.4
3.5
6.4
3.5
6.4
3.5
6.4
3.5
6.4
3.5
6.4
3.5
6.4
3.5
6.4
3.5
6.4
3.5
6.4
3.5
6.4
3.5
6.4
3.5
6.4
3.5
6.2
3.4
6.0
3.3
8.1
4.5
8.1
4.5
8.1
4.5
8.1
4.5
8.1
4.5
8.1
4.5
8.1
4.5
8.1
4.5
8.1
4.5
8.1
4.5
8.1
4.5
8.1
4.5
8.1
4.5
8.1
4.5
7.8
4.4
7.6
4.3
8
61
Floor Standing Cabinet Type ( MML-AP****H )
unit
size
007
8
009
012
015
62
outdoor
air temp.
o
C DB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
o
14.0 C WB
o
20 C DB
TC
SHC
1.8
1.2
1.8
1.2
1.8
1.2
1.8
1.2
1.8
1.2
1.8
1.2
1.8
1.2
1.8
1.2
1.8
1.2
1.8
1.2
1.8
1.2
1.8
1.2
1.8
1.2
1.8
1.2
1.7
1.2
1.7
1.2
2.3
1.4
2.3
1.4
2.3
1.4
2.3
1.4
2.3
1.4
2.3
1.4
2.3
1.4
2.3
1.4
2.3
1.4
2.3
1.4
2.3
1.4
2.3
1.4
2.3
1.4
2.3
1.4
2.2
1.4
2.2
1.3
3.0
2.0
3.0
2.0
3.0
2.0
3.0
2.0
3.0
2.0
3.0
2.0
3.0
2.0
3.0
2.0
3.0
2.0
3.0
2.0
3.0
2.0
3.0
2.0
3.0
2.0
3.0
2.0
2.9
1.9
2.8
1.8
3.5
2.3
3.5
2.3
3.5
2.3
3.5
2.3
3.5
2.3
3.5
2.3
3.5
2.3
3.5
2.3
3.5
2.3
3.5
2.3
3.5
2.3
3.5
2.3
3.5
2.3
3.6
2.4
3.5
2.3
3.4
2.3
o
16.0 C WB
o
23 C DB
TC
SHC
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
1.9
1.3
1.9
1.2
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.4
1.4
3.3
2.1
3.3
2.1
3.3
2.1
3.3
2.1
3.3
2.1
3.3
2.1
3.3
2.1
3.3
2.1
3.3
2.1
3.3
2.1
3.3
2.1
3.3
2.1
3.3
2.1
3.3
2.1
3.2
2.0
3.1
2.0
3.8
2.5
3.8
2.5
3.8
2.5
3.8
2.5
3.8
2.5
3.8
2.5
3.8
2.5
3.8
2.5
3.8
2.5
3.8
2.5
3.8
2.5
3.8
2.5
3.8
2.5
4.0
2.6
3.8
2.5
3.7
2.4
TC : Total capacity [kW]
indoor air temp.
o
o
o
18.0 C WB
19.0 C WB
20.0 C WB
o
o
o
26 C DB
27 C DB
28 C DB
TC
SHC
TC
SHC
TC
SHC
2.1
1.4
2.2
1.4
2.3
1.4
2.1
1.4
2.2
1.4
2.3
1.4
2.1
1.4
2.2
1.4
2.3
1.4
2.1
1.4
2.2
1.4
2.3
1.4
2.1
1.4
2.2
1.4
2.3
1.4
2.1
1.4
2.2
1.4
2.3
1.4
2.1
1.4
2.2
1.4
2.3
1.4
2.1
1.4
2.2
1.4
2.3
1.4
2.1
1.4
2.2
1.4
2.3
1.4
2.1
1.4
2.2
1.4
2.3
1.4
2.1
1.4
2.2
1.4
2.3
1.4
2.1
1.4
2.2
1.4
2.3
1.4
2.1
1.4
2.2
1.4
2.3
1.4
2.1
1.4
2.2
1.4
2.3
1.4
2.1
1.4
2.1
1.4
2.2
1.4
2.0
1.3
2.1
1.3
2.1
1.3
2.7
1.6
2.8
1.6
2.9
1.6
2.7
1.6
2.8
1.6
2.9
1.6
2.7
1.6
2.8
1.6
2.9
1.6
2.7
1.6
2.8
1.6
2.9
1.6
2.7
1.6
2.8
1.6
2.9
1.6
2.7
1.6
2.8
1.6
2.9
1.6
2.7
1.6
2.8
1.6
2.9
1.6
2.7
1.6
2.8
1.6
2.9
1.6
2.7
1.6
2.8
1.6
2.9
1.6
2.7
1.6
2.8
1.6
2.9
1.6
2.7
1.6
2.8
1.6
2.9
1.6
2.7
1.6
2.8
1.6
2.9
1.6
2.7
1.6
2.8
1.6
2.9
1.6
2.7
1.6
2.8
1.6
2.9
1.6
2.6
1.6
2.7
1.5
2.8
1.5
2.6
1.5
2.6
1.5
2.7
1.5
3.5
2.2
3.6
2.2
3.7
2.2
3.5
2.2
3.6
2.2
3.7
2.2
3.5
2.2
3.6
2.2
3.7
2.2
3.5
2.2
3.6
2.2
3.7
2.2
3.5
2.2
3.6
2.2
3.7
2.2
3.5
2.2
3.6
2.2
3.7
2.2
3.5
2.2
3.6
2.2
3.7
2.2
3.5
2.2
3.6
2.2
3.7
2.2
3.5
2.2
3.6
2.2
3.7
2.2
3.5
2.2
3.6
2.2
3.7
2.2
3.5
2.2
3.6
2.2
3.7
2.2
3.5
2.2
3.6
2.2
3.7
2.2
3.5
2.2
3.6
2.2
3.7
2.2
3.5
2.2
3.6
2.2
3.7
2.2
3.4
2.1
3.5
2.1
3.6
2.1
3.3
2.1
3.4
2.1
3.5
2.1
4.1
2.6
4.4
2.7
4.3
2.6
4.1
2.6
4.4
2.7
4.3
2.6
4.1
2.6
4.4
2.7
4.3
2.6
4.1
2.6
4.4
2.7
4.3
2.6
4.1
2.6
4.4
2.7
4.3
2.6
4.1
2.6
4.4
2.7
4.3
2.6
4.1
2.6
4.4
2.7
4.3
2.6
4.1
2.6
4.4
2.7
4.3
2.6
4.1
2.6
4.4
2.7
4.3
2.6
4.1
2.6
4.4
2.7
4.3
2.6
4.1
2.6
4.4
2.7
4.3
2.6
4.1
2.6
4.4
2.7
4.3
2.6
4.1
2.6
4.4
2.7
4.3
2.6
4.2
2.7
4.5
2.8
4.5
2.7
4.1
2.6
4.4
2.7
4.3
2.6
4.0
2.6
4.2
2.6
4.2
2.6
SHC : Sensible capacity [kW]
o
22.0 C WB
o
30 C DB
TC
SHC
2.4
1.4
2.4
1.4
2.4
1.4
2.4
1.4
2.4
1.4
2.4
1.4
2.4
1.4
2.4
1.4
2.4
1.4
2.4
1.4
2.4
1.4
2.4
1.4
2.4
1.4
2.4
1.4
2.3
1.3
2.3
1.3
3.1
1.6
3.1
1.6
3.1
1.6
3.1
1.6
3.1
1.6
3.1
1.6
3.1
1.6
3.1
1.6
3.1
1.6
3.1
1.6
3.1
1.6
3.1
1.6
3.1
1.6
3.1
1.6
3.0
1.5
2.9
1.5
3.9
2.2
3.9
2.2
3.9
2.2
3.9
2.2
3.9
2.2
3.9
2.2
3.9
2.2
3.9
2.2
3.9
2.2
3.9
2.2
3.9
2.2
3.9
2.2
3.9
2.2
3.9
2.2
3.8
2.1
3.7
2.1
4.6
2.6
4.6
2.6
4.6
2.6
4.6
2.6
4.6
2.6
4.6
2.6
4.6
2.6
4.6
2.6
4.6
2.6
4.6
2.6
4.6
2.6
4.6
2.6
4.6
2.6
4.7
2.7
4.6
2.6
4.5
2.5
o
24.0 C WB
o
32 C DB
TC
SHC
2.5
1.4
2.5
1.4
2.5
1.4
2.5
1.4
2.5
1.4
2.5
1.4
2.5
1.4
2.5
1.4
2.5
1.4
2.5
1.4
2.5
1.4
2.5
1.4
2.5
1.4
2.5
1.4
2.4
1.3
2.4
1.3
3.2
1.5
3.2
1.5
3.2
1.5
3.2
1.5
3.2
1.5
3.2
1.5
3.2
1.5
3.2
1.5
3.2
1.5
3.2
1.5
3.2
1.5
3.2
1.5
3.2
1.5
3.2
1.5
3.1
1.5
3.0
1.5
4.1
2.1
4.1
2.1
4.1
2.1
4.1
2.1
4.1
2.1
4.1
2.1
4.1
2.1
4.1
2.1
4.1
2.1
4.1
2.1
4.1
2.1
4.1
2.1
4.1
2.1
4.1
2.1
4.0
2.1
3.9
2.0
4.8
2.6
4.8
2.6
4.8
2.6
4.8
2.6
4.8
2.6
4.8
2.6
4.8
2.6
4.8
2.6
4.8
2.6
4.8
2.6
4.8
2.6
4.8
2.6
4.8
2.6
5.0
2.6
4.8
2.6
4.7
2.5
Floor Standing Cabinet Type ( MML-AP****H )
unit
size
018
024
outdoor
air temp.
o
C DB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
o
14.0 C WB
o
20 C DB
TC
SHC
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.5
3.0
4.3
2.9
5.8
4.0
5.8
4.0
5.8
4.0
5.8
4.0
5.8
4.0
5.8
4.0
5.8
4.0
5.8
4.0
5.8
4.0
5.8
4.0
5.8
4.0
5.8
4.0
5.8
4.0
5.8
4.0
5.6
3.9
5.5
3.8
o
16.0 C WB
o
23 C DB
TC
SHC
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
4.9
3.2
4.8
3.1
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.2
4.1
6.1
4.0
TC : Total
indoor air temp.
o
o
18.0 C WB
19.0 C WB
o
o
26 C DB
27 C DB
TC
SHC
TC
SHC
5.4
3.5
5.6
3.5
5.4
3.5
5.6
3.5
5.4
3.5
5.6
3.5
5.4
3.5
5.6
3.5
5.4
3.5
5.6
3.5
5.4
3.5
5.6
3.5
5.4
3.5
5.6
3.5
5.4
3.5
5.6
3.5
5.4
3.5
5.6
3.5
5.4
3.5
5.6
3.5
5.4
3.5
5.6
3.5
5.4
3.5
5.6
3.5
5.4
3.5
5.6
3.5
5.4
3.5
5.6
3.5
5.3
3.4
5.4
3.4
5.1
3.3
5.3
3.3
6.9
4.5
7.1
4.5
6.9
4.5
7.1
4.5
6.9
4.5
7.1
4.5
6.9
4.5
7.1
4.5
6.9
4.5
7.1
4.5
6.9
4.5
7.1
4.5
6.9
4.5
7.1
4.5
6.9
4.5
7.1
4.5
6.9
4.5
7.1
4.5
6.9
4.5
7.1
4.5
6.9
4.5
7.1
4.5
6.9
4.5
7.1
4.5
6.9
4.5
7.1
4.5
6.9
4.5
7.1
4.5
6.7
4.4
6.9
4.4
6.5
4.2
6.7
4.2
capacity [kW]
o
20.0 C WB
o
28 C DB
TC
SHC
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.6
3.4
5.4
3.3
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.1
4.4
6.9
4.2
SHC : Sensible capacity [kW]
o
22.0 C WB
o
30 C DB
TC
SHC
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
5.9
3.4
5.7
3.3
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.5
4.3
7.3
4.2
o
24.0 C WB
o
32 C DB
TC
SHC
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.2
3.3
6.0
3.2
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
7.8
4.2
7.6
4.1
8
63
Floor Standing Concealed Type ( MML-AP****BH )
unit
size
007
8
009
012
015
64
outdoor
air temp.
o
C DB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
o
14.0 C WB
o
20 C DB
TC
SHC
1.8
1.2
1.8
1.2
1.8
1.2
1.8
1.2
1.8
1.2
1.8
1.2
1.8
1.2
1.8
1.2
1.8
1.2
1.8
1.2
1.8
1.2
1.8
1.2
1.8
1.2
1.8
1.2
1.7
1.2
1.7
1.2
2.3
1.4
2.3
1.4
2.3
1.4
2.3
1.4
2.3
1.4
2.3
1.4
2.3
1.4
2.3
1.4
2.3
1.4
2.3
1.4
2.3
1.4
2.3
1.4
2.3
1.4
2.3
1.4
2.2
1.4
2.2
1.3
3.0
2.0
3.0
2.0
3.0
2.0
3.0
2.0
3.0
2.0
3.0
2.0
3.0
2.0
3.0
2.0
3.0
2.0
3.0
2.0
3.0
2.0
3.0
2.0
3.0
2.0
3.0
2.0
2.9
1.9
2.8
1.8
3.7
2.5
3.7
2.5
3.7
2.5
3.7
2.5
3.7
2.5
3.7
2.5
3.7
2.5
3.7
2.5
3.7
2.5
3.7
2.5
3.7
2.5
3.7
2.5
3.7
2.5
3.7
2.5
3.6
2.4
3.5
2.3
o
16.0 C WB
o
23 C DB
TC
SHC
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
1.9
1.3
1.9
1.2
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.4
1.4
3.3
2.1
3.3
2.1
3.3
2.1
3.3
2.1
3.3
2.1
3.3
2.1
3.3
2.1
3.3
2.1
3.3
2.1
3.3
2.1
3.3
2.1
3.3
2.1
3.3
2.1
3.3
2.1
3.2
2.0
3.1
2.0
4.1
2.7
4.1
2.7
4.1
2.7
4.1
2.7
4.1
2.7
4.1
2.7
4.1
2.7
4.1
2.7
4.1
2.7
4.1
2.7
4.1
2.7
4.1
2.7
4.1
2.7
4.1
2.7
4.0
2.6
3.8
2.5
TC : Total capacity [kW]
indoor air temp.
o
o
o
18.0 C WB
19.0 C WB
20.0 C WB
o
o
o
26 C DB
27 C DB
28 C DB
TC
SHC
TC
SHC
TC
SHC
2.1
1.4
2.2
1.4
2.3
1.4
2.1
1.4
2.2
1.4
2.3
1.4
2.1
1.4
2.2
1.4
2.3
1.4
2.1
1.4
2.2
1.4
2.3
1.4
2.1
1.4
2.2
1.4
2.3
1.4
2.1
1.4
2.2
1.4
2.3
1.4
2.1
1.4
2.2
1.4
2.3
1.4
2.1
1.4
2.2
1.4
2.3
1.4
2.1
1.4
2.2
1.4
2.3
1.4
2.1
1.4
2.2
1.4
2.3
1.4
2.1
1.4
2.2
1.4
2.3
1.4
2.1
1.4
2.2
1.4
2.3
1.4
2.1
1.4
2.2
1.4
2.3
1.4
2.1
1.4
2.2
1.4
2.3
1.4
2.1
1.4
2.1
1.4
2.2
1.4
2.0
1.3
2.1
1.3
2.1
1.3
2.7
1.6
2.8
1.6
2.9
1.6
2.7
1.6
2.8
1.6
2.9
1.6
2.7
1.6
2.8
1.6
2.9
1.6
2.7
1.6
2.8
1.6
2.9
1.6
2.7
1.6
2.8
1.6
2.9
1.6
2.7
1.6
2.8
1.6
2.9
1.6
2.7
1.6
2.8
1.6
2.9
1.6
2.7
1.6
2.8
1.6
2.9
1.6
2.7
1.6
2.8
1.6
2.9
1.6
2.7
1.6
2.8
1.6
2.9
1.6
2.7
1.6
2.8
1.6
2.9
1.6
2.7
1.6
2.8
1.6
2.9
1.6
2.7
1.6
2.8
1.6
2.9
1.6
2.7
1.6
2.8
1.6
2.9
1.6
2.6
1.6
2.7
1.5
2.8
1.5
2.6
1.5
2.6
1.5
2.7
1.5
3.5
2.2
3.6
2.2
3.7
2.2
3.5
2.2
3.6
2.2
3.7
2.2
3.5
2.2
3.6
2.2
3.7
2.2
3.5
2.2
3.6
2.2
3.7
2.2
3.5
2.2
3.6
2.2
3.7
2.2
3.5
2.2
3.6
2.2
3.7
2.2
3.5
2.2
3.6
2.2
3.7
2.2
3.5
2.2
3.6
2.2
3.7
2.2
3.5
2.2
3.6
2.2
3.7
2.2
3.5
2.2
3.6
2.2
3.7
2.2
3.5
2.2
3.6
2.2
3.7
2.2
3.5
2.2
3.6
2.2
3.7
2.2
3.5
2.2
3.6
2.2
3.7
2.2
3.5
2.2
3.6
2.2
3.7
2.2
3.4
2.1
3.5
2.1
3.6
2.1
3.3
2.1
3.4
2.1
3.5
2.1
4.4
2.8
4.5
2.8
4.6
2.8
4.4
2.8
4.5
2.8
4.6
2.8
4.4
2.8
4.5
2.8
4.6
2.8
4.4
2.8
4.5
2.8
4.6
2.8
4.4
2.8
4.5
2.8
4.6
2.8
4.4
2.8
4.5
2.8
4.6
2.8
4.4
2.8
4.5
2.8
4.6
2.8
4.4
2.8
4.5
2.8
4.6
2.8
4.4
2.8
4.5
2.8
4.6
2.8
4.4
2.8
4.5
2.8
4.6
2.8
4.4
2.8
4.5
2.8
4.6
2.8
4.4
2.8
4.5
2.8
4.6
2.8
4.4
2.8
4.5
2.8
4.6
2.8
4.4
2.8
4.5
2.8
4.6
2.8
4.2
2.7
4.4
2.7
4.5
2.7
4.1
2.7
4.2
2.6
4.4
2.6
SHC : Sensible capacity [kW]
o
22.0 C WB
o
30 C DB
TC
SHC
2.4
1.4
2.4
1.4
2.4
1.4
2.4
1.4
2.4
1.4
2.4
1.4
2.4
1.4
2.4
1.4
2.4
1.4
2.4
1.4
2.4
1.4
2.4
1.4
2.4
1.4
2.4
1.4
2.3
1.3
2.3
1.3
3.1
1.6
3.1
1.6
3.1
1.6
3.1
1.6
3.1
1.6
3.1
1.6
3.1
1.6
3.1
1.6
3.1
1.6
3.1
1.6
3.1
1.6
3.1
1.6
3.1
1.6
3.1
1.6
3.0
1.5
2.9
1.5
3.9
2.2
3.9
2.2
3.9
2.2
3.9
2.2
3.9
2.2
3.9
2.2
3.9
2.2
3.9
2.2
3.9
2.2
3.9
2.2
3.9
2.2
3.9
2.2
3.9
2.2
3.9
2.2
3.8
2.1
3.7
2.1
4.9
2.8
4.9
2.8
4.9
2.8
4.9
2.8
4.9
2.8
4.9
2.8
4.9
2.8
4.9
2.8
4.9
2.8
4.9
2.8
4.9
2.8
4.9
2.8
4.9
2.8
4.9
2.8
4.7
2.7
4.6
2.6
o
24.0 C WB
o
32 C DB
TC
SHC
2.5
1.4
2.5
1.4
2.5
1.4
2.5
1.4
2.5
1.4
2.5
1.4
2.5
1.4
2.5
1.4
2.5
1.4
2.5
1.4
2.5
1.4
2.5
1.4
2.5
1.4
2.5
1.4
2.4
1.3
2.4
1.3
3.2
1.5
3.2
1.5
3.2
1.5
3.2
1.5
3.2
1.5
3.2
1.5
3.2
1.5
3.2
1.5
3.2
1.5
3.2
1.5
3.2
1.5
3.2
1.5
3.2
1.5
3.2
1.5
3.1
1.5
3.0
1.5
4.1
2.1
4.1
2.1
4.1
2.1
4.1
2.1
4.1
2.1
4.1
2.1
4.1
2.1
4.1
2.1
4.1
2.1
4.1
2.1
4.1
2.1
4.1
2.1
4.1
2.1
4.1
2.1
4.0
2.1
3.9
2.0
5.1
2.7
5.1
2.7
5.1
2.7
5.1
2.7
5.1
2.7
5.1
2.7
5.1
2.7
5.1
2.7
5.1
2.7
5.1
2.7
5.1
2.7
5.1
2.7
5.1
2.7
5.1
2.7
5.0
2.6
4.8
2.6
Floor Standing Concealed Type ( MML-AP****BH )
unit
size
018
024
outdoor
air temp.
o
C DB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
o
14.0 CWB
o
20 CDB
TC
SHC
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.5
3.0
4.3
2.9
5.8
4.0
5.8
4.0
5.8
4.0
5.8
4.0
5.8
4.0
5.8
4.0
5.8
4.0
5.8
4.0
5.8
4.0
5.8
4.0
5.8
4.0
5.8
4.0
5.8
4.0
5.8
4.0
5.6
3.9
5.5
3.8
o
16.0 CWB
o
23 CDB
TC
SHC
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
4.9
3.2
4.8
3.1
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.2
4.1
6.1
4.0
TC : Total
indoor air temp.
o
o
18.0 CWB
19.0 CWB
o
o
26 CDB
27 CDB
TC
SHC
TC
SHC
5.4
3.5
5.6
3.5
5.4
3.5
5.6
3.5
5.4
3.5
5.6
3.5
5.4
3.5
5.6
3.5
5.4
3.5
5.6
3.5
5.4
3.5
5.6
3.5
5.4
3.5
5.6
3.5
5.4
3.5
5.6
3.5
5.4
3.5
5.6
3.5
5.4
3.5
5.6
3.5
5.4
3.5
5.6
3.5
5.4
3.5
5.6
3.5
5.4
3.5
5.6
3.5
5.4
3.5
5.6
3.5
5.3
3.4
5.4
3.4
5.1
3.3
5.3
3.3
6.9
4.5
7.1
4.5
6.9
4.5
7.1
4.5
6.9
4.5
7.1
4.5
6.9
4.5
7.1
4.5
6.9
4.5
7.1
4.5
6.9
4.5
7.1
4.5
6.9
4.5
7.1
4.5
6.9
4.5
7.1
4.5
6.9
4.5
7.1
4.5
6.9
4.5
7.1
4.5
6.9
4.5
7.1
4.5
6.9
4.5
7.1
4.5
6.9
4.5
7.1
4.5
6.9
4.5
7.1
4.5
6.7
4.4
6.9
4.4
6.5
4.2
6.7
4.2
capacity [kW]
o
20.0 CWB
o
28 CDB
TC
SHC
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.6
3.4
5.4
3.3
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.1
4.4
6.9
4.2
SHC : Sensible capacity [kW]
o
22.0 CWB
o
30 CDB
TC
SHC
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
5.9
3.4
5.7
3.3
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.5
4.3
7.3
4.2
o
24.0 CWB
o
32 CDB
TC
SHC
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.2
3.3
6.0
3.2
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
7.8
4.2
7.6
4.1
8
65
Floor Standing Type ( MMF-AP****H )
unit
size
015
8
018
024
027
66
outdoor
air temp.
o
C DB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
o
14.0 C WB
o
20 C DB
TC
SHC
3.7
3.0
3.7
3.0
3.7
3.0
3.7
3.0
3.7
3.0
3.7
3.0
3.7
3.0
3.7
3.0
3.7
3.0
3.7
3.0
3.7
3.0
3.7
3.0
3.7
3.0
3.7
3.0
3.6
2.9
3.5
2.8
4.6
3.6
4.6
3.6
4.6
3.6
4.6
3.6
4.6
3.6
4.6
3.6
4.6
3.6
4.6
3.6
4.6
3.6
4.6
3.6
4.6
3.6
4.6
3.6
4.6
3.6
4.6
3.6
4.5
3.5
4.3
3.4
5.8
4.7
5.8
4.7
5.8
4.7
5.8
4.7
5.8
4.7
5.8
4.7
5.8
4.7
5.8
4.7
5.8
4.7
5.8
4.7
5.8
4.7
5.8
4.7
5.8
4.7
5.8
4.7
5.6
4.5
5.5
4.4
6.6
5.2
6.6
5.2
6.6
5.2
6.6
5.2
6.6
5.2
6.6
5.2
6.6
5.2
6.6
5.2
6.6
5.2
6.6
5.2
6.6
5.2
6.6
5.2
6.6
5.2
6.6
5.2
6.4
5.1
6.2
4.9
o
16.0 C WB
o
23 C DB
TC
SHC
4.1
3.2
4.1
3.2
4.1
3.2
4.1
3.2
4.1
3.2
4.1
3.2
4.1
3.2
4.1
3.2
4.1
3.2
4.1
3.2
4.1
3.2
4.1
3.2
4.1
3.2
4.1
3.2
4.0
3.1
3.8
3.0
5.1
3.9
5.1
3.9
5.1
3.9
5.1
3.9
5.1
3.9
5.1
3.9
5.1
3.9
5.1
3.9
5.1
3.9
5.1
3.9
5.1
3.9
5.1
3.9
5.1
3.9
5.1
3.9
4.9
3.7
4.8
3.6
6.4
5.0
6.4
5.0
6.4
5.0
6.4
5.0
6.4
5.0
6.4
5.0
6.4
5.0
6.4
5.0
6.4
5.0
6.4
5.0
6.4
5.0
6.4
5.0
6.4
5.0
6.4
5.0
6.2
4.8
6.1
4.7
7.3
5.6
7.3
5.6
7.3
5.6
7.3
5.6
7.3
5.6
7.3
5.6
7.3
5.6
7.3
5.6
7.3
5.6
7.3
5.6
7.3
5.6
7.3
5.6
7.3
5.6
7.3
5.6
7.0
5.4
6.8
5.2
TC : Total capacity [kW]
indoor air temp.
o
o
o
18.0 C WB
19.0 C WB
20.0 C WB
o
o
o
26 C DB
27 C DB
28 C DB
TC
SHC
TC
SHC
TC
SHC
4.4
3.4
4.5
3.4
4.6
3.4
4.4
3.4
4.5
3.4
4.6
3.4
4.4
3.4
4.5
3.4
4.6
3.4
4.4
3.4
4.5
3.4
4.6
3.4
4.4
3.4
4.5
3.4
4.6
3.4
4.4
3.4
4.5
3.4
4.6
3.4
4.4
3.4
4.5
3.4
4.6
3.4
4.4
3.4
4.5
3.4
4.6
3.4
4.4
3.4
4.5
3.4
4.6
3.4
4.4
3.4
4.5
3.4
4.6
3.4
4.4
3.4
4.5
3.4
4.6
3.4
4.4
3.4
4.5
3.4
4.6
3.4
4.4
3.4
4.5
3.4
4.6
3.4
4.4
3.4
4.5
3.4
4.6
3.4
4.2
3.3
4.4
3.3
4.5
3.3
4.1
3.2
4.2
3.2
4.4
3.2
5.4
4.1
5.6
4.1
5.8
4.1
5.4
4.1
5.6
4.1
5.8
4.1
5.4
4.1
5.6
4.1
5.8
4.1
5.4
4.1
5.6
4.1
5.8
4.1
5.4
4.1
5.6
4.1
5.8
4.1
5.4
4.1
5.6
4.1
5.8
4.1
5.4
4.1
5.6
4.1
5.8
4.1
5.4
4.1
5.6
4.1
5.8
4.1
5.4
4.1
5.6
4.1
5.8
4.1
5.4
4.1
5.6
4.1
5.8
4.1
5.4
4.1
5.6
4.1
5.8
4.1
5.4
4.1
5.6
4.1
5.8
4.1
5.4
4.1
5.6
4.1
5.8
4.1
5.4
4.1
5.6
4.1
5.8
4.1
5.3
4.0
5.4
4.0
5.6
4.0
5.1
3.9
5.3
3.9
5.4
3.9
6.9
5.3
7.1
5.3
7.3
5.3
6.9
5.3
7.1
5.3
7.3
5.3
6.9
5.3
7.1
5.3
7.3
5.3
6.9
5.3
7.1
5.3
7.3
5.3
6.9
5.3
7.1
5.3
7.3
5.3
6.9
5.3
7.1
5.3
7.3
5.3
6.9
5.3
7.1
5.3
7.3
5.3
6.9
5.3
7.1
5.3
7.3
5.3
6.9
5.3
7.1
5.3
7.3
5.3
6.9
5.3
7.1
5.3
7.3
5.3
6.9
5.3
7.1
5.3
7.3
5.3
6.9
5.3
7.1
5.3
7.3
5.3
6.9
5.3
7.1
5.3
7.3
5.3
6.9
5.3
7.1
5.3
7.3
5.3
6.7
5.1
6.9
5.1
7.1
5.1
6.5
5.0
6.7
5.0
6.9
5.0
7.8
5.9
8.0
5.9
8.2
5.9
7.8
5.9
8.0
5.9
8.2
5.9
7.8
5.9
8.0
5.9
8.2
5.9
7.8
5.9
8.0
5.9
8.2
5.9
7.8
5.9
8.0
5.9
8.2
5.9
7.8
5.9
8.0
5.9
8.2
5.9
7.8
5.9
8.0
5.9
8.2
5.9
7.8
5.9
8.0
5.9
8.2
5.9
7.8
5.9
8.0
5.9
8.2
5.9
7.8
5.9
8.0
5.9
8.2
5.9
7.8
5.9
8.0
5.9
8.2
5.9
7.8
5.9
8.0
5.9
8.2
5.9
7.8
5.9
8.0
5.9
8.2
5.9
7.8
5.9
8.0
5.9
8.2
5.9
7.5
5.7
7.7
5.7
8.0
5.7
7.3
5.6
7.5
5.6
7.8
5.6
SHC : Sensible capacity [kW]
o
22.0 C WB
o
30 C DB
TC
SHC
4.9
3.4
4.9
3.4
4.9
3.4
4.9
3.4
4.9
3.4
4.9
3.4
4.9
3.4
4.9
3.4
4.9
3.4
4.9
3.4
4.9
3.4
4.9
3.4
4.9
3.4
4.9
3.4
4.7
3.3
4.6
3.2
6.1
4.1
6.1
4.1
6.1
4.1
6.1
4.1
6.1
4.1
6.1
4.1
6.1
4.1
6.1
4.1
6.1
4.1
6.1
4.1
6.1
4.1
6.1
4.1
6.1
4.1
6.1
4.1
5.9
3.9
5.7
3.8
7.7
5.3
7.7
5.3
7.7
5.3
7.7
5.3
7.7
5.3
7.7
5.3
7.7
5.3
7.7
5.3
7.7
5.3
7.7
5.3
7.7
5.3
7.7
5.3
7.7
5.3
7.7
5.3
7.5
5.1
7.3
4.9
8.7
5.8
8.7
5.8
8.7
5.8
8.7
5.8
8.7
5.8
8.7
5.8
8.7
5.8
8.7
5.8
8.7
5.8
8.7
5.8
8.7
5.8
8.7
5.8
8.7
5.8
8.7
5.8
8.4
5.7
8.2
5.5
o
24.0 C WB
o
32 C DB
TC
SHC
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.0
3.2
4.8
3.1
6.4
4.0
6.4
4.0
6.4
4.0
6.4
4.0
6.4
4.0
6.4
4.0
6.4
4.0
6.4
4.0
6.4
4.0
6.4
4.0
6.4
4.0
6.4
4.0
6.4
4.0
6.4
4.0
6.2
3.8
6.0
3.7
8.1
5.1
8.1
5.1
8.1
5.1
8.1
5.1
8.1
5.1
8.1
5.1
8.1
5.1
8.1
5.1
8.1
5.1
8.1
5.1
8.1
5.1
8.1
5.1
8.1
5.1
8.1
5.1
7.8
5.0
7.6
4.8
9.1
5.7
9.1
5.7
9.1
5.7
9.1
5.7
9.1
5.7
9.1
5.7
9.1
5.7
9.1
5.7
9.1
5.7
9.1
5.7
9.1
5.7
9.1
5.7
9.1
5.7
9.1
5.7
8.8
5.5
8.6
5.4
Floor Standing Type ( MMF-AP****H )
unit
size
036
048
056
outdoor
air temp.
o
C DB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
o
14.0 C WB
o
20 CDB
TC
SHC
9.2
7.1
9.2
7.1
9.2
7.1
9.2
7.1
9.2
7.1
9.2
7.1
9.2
7.1
9.2
7.1
9.2
7.1
9.2
7.1
9.2
7.1
9.2
7.1
9.2
7.1
9.2
7.1
8.9
6.9
8.7
6.7
11.5
8.8
11.5
8.8
11.5
8.8
11.5
8.8
11.5
8.8
11.5
8.8
11.5
8.8
11.5
8.8
11.5
8.8
11.5
8.8
11.5
8.8
11.5
8.8
11.5
8.8
11.5
8.8
11.1
8.5
10.8
8.3
13.1
10.1
13.1
10.1
13.1
10.1
13.1
10.1
13.1
10.1
13.1
10.1
13.1
10.1
13.1
10.1
13.1
10.1
13.1
10.1
13.1
10.1
13.1
10.1
13.1
10.1
13.1
10.1
12.7
9.8
12.4
9.5
o
16.0 C WB
o
23 C DB
TC
SHC
10.2
7.6
10.2
7.6
10.2
7.6
10.2
7.6
10.2
7.6
10.2
7.6
10.2
7.6
10.2
7.6
10.2
7.6
10.2
7.6
10.2
7.6
10.2
7.6
10.2
7.6
10.2
7.6
9.8
7.3
9.6
7.1
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.3
9.0
12.0
8.8
14.5
10.8
14.5
10.8
14.5
10.8
14.5
10.8
14.5
10.8
14.5
10.8
14.5
10.8
14.5
10.8
14.5
10.8
14.5
10.8
14.5
10.8
14.5
10.8
14.5
10.8
14.5
10.8
14.1
10.4
13.7
10.1
TC : Total capacity [kW]
indoor air temp.
o
o
o
18.0 C WB
19.0 C WB
20.0 C WB
o
o
o
26 C DB
27 C DB
28 C DB
TC
SHC
TC
SHC
TC
SHC
10.9
8.0
11.2
8.0
11.5
8.0
10.9
8.0
11.2
8.0
11.5
8.0
10.9
8.0
11.2
8.0
11.5
8.0
10.9
8.0
11.2
8.0
11.5
8.0
10.9
8.0
11.2
8.0
11.5
8.0
10.9
8.0
11.2
8.0
11.5
8.0
10.9
8.0
11.2
8.0
11.5
8.0
10.9
8.0
11.2
8.0
11.5
8.0
10.9
8.0
11.2
8.0
11.5
8.0
10.9
8.0
11.2
8.0
11.5
8.0
10.9
8.0
11.2
8.0
11.5
8.0
10.9
8.0
11.2
8.0
11.5
8.0
10.9
8.0
11.2
8.0
11.5
8.0
10.9
8.0
11.2
8.0
11.5
8.0
10.5
7.8
10.8
7.7
11.2
7.7
10.2
7.6
10.5
7.5
10.9
7.5
13.6
9.9
14.0
9.9
14.4
9.9
13.6
9.9
14.0
9.9
14.4
9.9
13.6
9.9
14.0
9.9
14.4
9.9
13.6
9.9
14.0
9.9
14.4
9.9
13.6
9.9
14.0
9.9
14.4
9.9
13.6
9.9
14.0
9.9
14.4
9.9
13.6
9.9
14.0
9.9
14.4
9.9
13.6
9.9
14.0
9.9
14.4
9.9
13.6
9.9
14.0
9.9
14.4
9.9
13.6
9.9
14.0
9.9
14.4
9.9
13.6
9.9
14.0
9.9
14.4
9.9
13.6
9.9
14.0
9.9
14.4
9.9
13.6
9.9
14.0
9.9
14.4
9.9
13.6
9.9
14.0
9.9
14.4
9.9
13.1
9.6
13.6
9.6
14.0
9.6
12.8
9.3
13.2
9.3
13.6
9.3
15.5
11.4
16.0
11.4
16.5
11.4
15.5
11.4
16.0
11.4
16.5
11.4
15.5
11.4
16.0
11.4
16.5
11.4
15.5
11.4
16.0
11.4
16.5
11.4
15.5
11.4
16.0
11.4
16.5
11.4
15.5
11.4
16.0
11.4
16.5
11.4
15.5
11.4
16.0
11.4
16.5
11.4
15.5
11.4
16.0
11.4
16.5
11.4
15.5
11.4
16.0
11.4
16.5
11.4
15.5
11.4
16.0
11.4
16.5
11.4
15.5
11.4
16.0
11.4
16.5
11.4
15.5
11.4
16.0
11.4
16.5
11.4
15.5
11.4
16.0
11.4
16.5
11.4
15.5
11.4
16.0
11.4
16.5
11.4
15.0
11.1
15.5
11.0
16.0
11.0
14.6
10.8
15.1
10.7
15.5
10.7
SHC : Sensible capacity [kW]
o
22.0 C WB
o
30 C DB
TC
SHC
12.2
7.9
12.2
7.9
12.2
7.9
12.2
7.9
12.2
7.9
12.2
7.9
12.2
7.9
12.2
7.9
12.2
7.9
12.2
7.9
12.2
7.9
12.2
7.9
12.2
7.9
12.2
7.9
11.8
7.7
11.5
7.5
15.3
9.8
15.3
9.8
15.3
9.8
15.3
9.8
15.3
9.8
15.3
9.8
15.3
9.8
15.3
9.8
15.3
9.8
15.3
9.8
15.3
9.8
15.3
9.8
15.3
9.8
15.3
9.8
14.8
9.5
14.4
9.2
17.4
11.3
17.4
11.3
17.4
11.3
17.4
11.3
17.4
11.3
17.4
11.3
17.4
11.3
17.4
11.3
17.4
11.3
17.4
11.3
17.4
11.3
17.4
11.3
17.4
11.3
17.4
11.3
16.9
10.9
16.4
10.6
o
24.0 C WB
o
32 C DB
TC
SHC
12.8
7.7
12.8
7.7
12.8
7.7
12.8
7.7
12.8
7.7
12.8
7.7
12.8
7.7
12.8
7.7
12.8
7.7
12.8
7.7
12.8
7.7
12.8
7.7
12.8
7.7
12.8
7.7
12.4
7.5
12.0
7.3
16.0
9.6
16.0
9.6
16.0
9.6
16.0
9.6
16.0
9.6
16.0
9.6
16.0
9.6
16.0
9.6
16.0
9.6
16.0
9.6
16.0
9.6
16.0
9.6
16.0
9.6
16.0
9.6
15.4
9.3
15.0
9.0
18.2
11.0
18.2
11.0
18.2
11.0
18.2
11.0
18.2
11.0
18.2
11.0
18.2
11.0
18.2
11.0
18.2
11.0
18.2
11.0
18.2
11.0
18.2
11.0
18.2
11.0
18.2
11.0
17.7
10.7
17.2
10.4
8
67
68
9
Part load performance
69
Foreword
70
9
Foreword
Part load performance
Part Load Performance
MMY-MAP0501 (5HP, 14kW system)
Cooling
Compressor + Oudoor Fan
Power consumption (kW)
Outdoor Outdoor
90%
80%
70%
60%
50%
40%
30%
Unit
Unit 100% 100%
Dry-Bulb Cooling Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity
( C)
Capacity
(kW)
40 C
13.0
3.86
3.16
2.54
2.02
1.59
1.24
1.03
0.88
o
o
o
14.0
3.65
2.98
2.40
1.90
1.49
1.16
0.96
0.82
o
14.0
3.02
2.48
2.00
1.60
1.27
1.00
0.84
0.73
o
14.0
2.71
2.22
1.80
1.45
1.15
0.92
0.78
0.68
o
14.0
2.52
2.07
1.68
1.35
1.08
0.87
0.74
0.65
o
14.0
2.34
1.93
1.57
1.26
1.01
0.82
0.70
0.61
35 C
30 C
25 C
20 C
15 C
Indoor air temperature conditions : 27.0
Heating
dry-bulb / 19.0
Compressor + Oudoor Fan
wet bulb
9
Power consumption (kW)
Outdoor Outdoor
90%
80%
70%
60%
50%
40%
30%
Unit
Unit 100% 100%
Capacity
Capacity
Capacity
Capacity
Capacity
Capacity
Capacity
Capacity
Dry-Bulb Heating
Capacity
( C)
(kW)
16.0
3.35
2.80
2.32
1.90
1.53
1.23
0.99
0.80
15 C
o
o
o
11 C
16.0
3.61
3.01
2.48
2.01
1.61
1.28
1.01
0.81
o
7C
16.0
3.84
3.19
2.62
2.12
1.69
1.32
1.03
0.81
o
1C
14.9
3.90
3.24
2.65
2.14
1.69
1.32
1.02
0.80
o
12.8
3.63
3.02
2.47
1.99
1.58
1.24
0.96
0.75
10.9
3.26
2.72
2.23
1.81
1.44
1.14
0.89
0.71
-5 C
o
-10 C
Indoor air temperature conditions : 20.0
dry-bulb
71
Part Load Performance
MMY-MAP0601 (6HP, 16kW system)
Cooling
Compressor + Oudoor Fan
Power consumption (kW)
Outdoor Outdoor
90%
80%
70%
60%
50%
40%
30%
Unit 100% 100%
Unit
Capacity
Capacity
Capacity
Capacity
Capacity
Capacity
Capacity
Capacity
Cooling
Dry-Bulb
( C)
Capacity
(kW)
40 C
14.9
4.91
4.01
3.23
2.57
2.02
1.58
1.26
1.05
o
o
o
16.0
4.64
3.79
3.05
2.42
1.90
1.48
1.17
0.97
o
16.0
3.84
3.15
2.55
2.03
1.61
1.28
1.03
0.87
o
16.0
3.44
2.83
2.29
1.84
1.46
1.17
0.95
0.82
o
16.0
3.20
2.63
2.14
1.72
1.37
1.10
0.90
0.78
o
16.0
2.97
2.45
1.99
1.61
1.29
1.04
0.86
0.74
35 C
30 C
25 C
20 C
15 C
Indoor air temperature conditions : 27.0
9
Heating
dry-bulb / 19.0
Compressor + Oudoor Fan
wet bulb
Power consumption (kW)
Outdoor Outdoor
90%
80%
70%
60%
50%
40%
30%
Unit 100% 100%
Unit
Dry-Bulb Heating Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity
Capacity
( C)
(kW)
15 C
18.0
3.97
3.33
2.76
2.25
1.82
1.46
1.17
0.96
o
o
o
11 C
18.0
4.28
3.57
2.94
2.39
1.92
1.52
1.20
0.96
o
7C
18.0
4.56
3.79
3.11
2.52
2.00
1.57
1.23
0.97
o
1C
16.7
4.64
3.85
3.15
2.54
2.01
1.57
1.22
0.95
o
14.4
4.31
3.58
2.93
2.37
1.88
1.47
1.14
0.89
12.2
3.87
3.23
2.65
2.15
1.71
1.35
1.06
0.84
-5 C
o
-10 C
Indoor air temperature conditions : 20.0
72
dry-bulb
Foreword
Part Load Performance
MMY-MAP0801 (8HP, 22.4kW system)
Cooling
Compressor + Oudoor Fan
Power consumption (kW)
Outdoor Outdoor
90%
80%
70%
60%
50%
40%
30%
Unit 100% 100%
Unit
Capacity
Capacity
Capacity
Capacity
Capacity
Capacity
Capacity
Capacity
Cooling
Dry-Bulb
( C)
Capacity
(kW)
40 C
20.8
6.00
4.91
3.95
3.14
2.47
1.93
1.54
1.28
o
o
o
22.4
5.67
4.63
3.73
2.96
2.32
1.81
1.43
1.19
o
22.4
4.69
3.85
3.11
2.49
1.97
1.56
1.26
1.07
o
22.4
4.20
3.45
2.80
2.25
1.79
1.43
1.16
1.00
o
22.4
3.91
3.21
2.61
2.10
1.68
1.35
1.10
0.95
o
22.4
3.63
2.99
2.44
1.96
1.57
1.27
1.05
0.91
35 C
30 C
25 C
20 C
15 C
Indoor air temperature conditions : 27.0
Heating
dry-bulb / 19.0
Compressor + Oudoor Fan
wet bulb
9
Power consumption (kW)
Outdoor Outdoor
90%
80%
70%
60%
50%
40%
30%
Unit 100% 100%
Unit
Dry-Bulb Heating Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity
Capacity
( C)
(kW)
25.0
5.12
4.29
3.55
2.91
2.35
1.89
1.51
1.23
15 C
o
o
o
11 C
25.0
5.52
4.61
3.79
3.08
2.47
1.96
1.55
1.24
o
7C
25.0
5.88
4.89
4.01
3.24
2.58
2.03
1.58
1.25
o
1C
23.3
5.98
4.97
4.06
3.27
2.59
2.02
1.57
1.22
o
20.0
5.55
4.62
3.78
3.05
2.42
1.90
1.47
1.15
17.0
5.00
4.16
3.42
2.77
2.21
1.74
1.37
1.08
-5 C
o
-10 C
Indoor air temperature conditions : 20.0
dry-bulb
73
Part Load Performance
MMY-MAP1001 (10HP, 28kW system)
Cooling
Compressor + Oudoor Fan
Power consumption (kW)
Outdoor Outdoor
90%
80%
70%
60%
50%
40%
30%
Unit 100% 100%
Unit
Capacity
Capacity
Capacity
Capacity
Capacity
Capacity
Capacity
Capacity
Cooling
Dry-Bulb
( C)
Capacity
(kW)
40 C
26.0
8.13
6.65
5.35
4.25
3.34
2.62
2.08
1.73
o
o
o
28.0
7.68
6.27
5.05
4.00
3.14
2.45
1.94
1.61
o
28.0
6.36
5.21
4.22
3.37
2.67
2.11
1.71
1.45
o
28.0
5.69
4.68
3.79
3.04
2.42
1.93
1.58
1.35
o
28.0
5.29
4.35
3.54
2.84
2.27
1.82
1.50
1.29
o
28.0
4.92
4.05
3.30
2.66
2.13
1.72
1.42
1.23
35 C
30 C
25 C
20 C
15 C
Indoor air temperature conditions : 27.0
9
Heating
dry-bulb / 19.0
Compressor + Oudoor Fan
wet bulb
Power consumption (kW)
Outdoor Outdoor
90%
80%
70%
60%
50%
40%
30%
Unit 100% 100%
Unit
Dry-Bulb Heating Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity
Capacity
( C)
(kW)
31.5
6.94
5.82
4.82
3.94
3.18
2.56
2.05
1.67
15 C
o
o
o
11 C
31.5
7.49
6.25
5.14
4.18
3.35
2.65
2.10
1.68
o
7C
31.5
7.97
6.63
5.44
4.40
3.50
2.75
2.15
1.69
o
1C
29.3
8.10
6.73
5.51
4.44
3.52
2.74
2.12
1.66
o
25.2
7.53
6.26
5.13
4.13
3.28
2.57
2.00
1.56
21.4
6.77
5.64
4.63
3.75
2.99
2.36
1.85
1.47
-5 C
o
-10 C
Indoor air temperature conditions : 20.0
74
dry-bulb
Part Load Performance
MMY-MAP1201 (12HP, 33.5kW system)
Cooling
Compressor + Oudoor Fan
Power consumption (kW)
Outdoor Outdoor
90%
80%
70%
60%
50%
40%
30%
Unit 100% 100%
Unit
Capacity
Capacity
Capacity
Capacity
Capacity
Capacity
Capacity
Capacity
Cooling
Dry-Bulb
( C)
Capacity
(kW)
40 C
31.2
12.61
9.39
7.47
5.82
4.44
3.32
2.48
1.92
o
o
o
33.5
11.92
8.87
7.05
5.49
4.18
3.12
2.33
1.79
o
33.5
9.87
7.33
5.85
4.57
3.51
2.65
2.01
1.58
o
33.5
8.84
6.56
5.24
4.11
3.17
2.41
1.85
1.47
o
33.5
8.22
6.10
4.88
3.83
2.96
2.26
1.74
1.40
o
33.5
7.64
5.66
4.54
3.57
2.76
2.12
1.64
1.33
35 C
30 C
25 C
20 C
15 C
Indoor air temperature conditions : 27.0
Heating
dry-bulb / 19.0
Compressor + Oudoor Fan
wet bulb
9
Power consumption (kW)
Outdoor Outdoor
90%
80%
70%
60%
50%
40%
30%
Unit 100% 100%
Unit
Dry-Bulb Heating Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity
Capacity
( C)
(kW)
37.5
8.88
7.53
6.26
5.14
4.06
3.15
2.42
1.87
15 C
o
o
o
11 C
37.5
9.57
8.12
6.73
5.50
4.31
3.31
2.51
1.90
o
7C
37.5
10.19
8.66
7.16
5.82
4.54
3.46
2.59
1.93
o
1C
34.9
10.36
8.81
7.27
5.90
4.58
3.48
2.58
1.91
o
30.0
9.63
8.18
6.76
5.49
4.27
3.25
2.42
1.79
25.5
8.66
7.35
6.08
4.96
3.87
2.96
2.23
1.67
-5 C
o
-10 C
Indoor air temperature conditions : 20.0
dry-bulb
75
Part Load Performance
MMY-AP1601 (16HP, 45kW system)
Cooling
Compressor + Oudoor Fan
Power consumption (kW)
Outdoor Outdoor
90%
80%
70%
60%
50%
40%
30%
Unit 100% 100%
Unit
Capacity
Capacity
Capacity
Capacity
Capacity
Capacity
Capacity
Capacity
Cooling
Dry-Bulb
( C)
Capacity
(kW)
40 C
41.9
12.91
10.01
8.11
6.48
5.13
4.06
3.27
2.76
o
o
o
45.0
12.20
9.46
7.66
6.11
4.83
3.82
3.07
2.58
o
45.0
10.10
7.90
6.43
5.17
4.14
3.32
2.72
2.34
o
45.0
9.04
7.11
5.80
4.69
3.78
3.05
2.53
2.20
o
45.0
8.41
6.63
5.42
4.40
3.55
2.89
2.41
2.10
o
45.0
7.82
6.19
5.07
4.13
3.35
2.73
2.29
2.02
35 C
30 C
25 C
20 C
15 C
Indoor air temperature conditions : 27.0
9
Heating
dry-bulb / 19.0
Compressor + Oudoor Fan
wet bulb
Power consumption (kW)
Outdoor Outdoor
90%
80%
70%
60%
50%
40%
30%
Unit 100% 100%
Unit
Dry-Bulb Heating Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity
Capacity
( C)
(kW)
50.0
10.70
8.80
7.33
6.03
4.92
3.99
3.25
2.69
15 C
o
o
o
11 C
50.0
11.53
9.44
7.81
6.38
5.16
4.14
3.31
2.69
o
7C
50.0
12.28
10.00
8.25
6.71
5.38
4.28
3.39
2.71
o
1C
46.5
12.49
10.15
8.35
6.77
5.41
4.27
3.36
2.66
o
40.0
11.60
9.45
7.78
6.32
5.06
4.01
3.17
2.53
34.0
10.43
8.54
7.06
5.76
4.64
3.70
2.95
2.39
-5 C
o
-10 C
Indoor air temperature conditions : 20.0
76
dry-bulb
Part Load Performance
MMY-AP2001 (20HP, 56kW system)
Cooling
Compressor + Oudoor Fan
Power consumption (kW)
Outdoor Outdoor
90%
80%
70%
60%
50%
40%
30%
Unit 100% 100%
Unit
Capacity
Capacity
Capacity
Capacity
Capacity
Capacity
Capacity
Capacity
Cooling
Dry-Bulb
( C)
Capacity
(kW)
40 C
52.1
17.11
13.49
10.91
8.70
6.88
5.43
4.36
3.67
o
o
o
56.0
16.17
12.75
10.30
8.21
6.48
5.10
4.09
3.43
o
56.0
13.38
10.62
8.63
6.93
5.53
4.42
3.61
3.09
o
56.0
11.99
9.56
7.79
6.28
5.04
4.07
3.35
2.90
o
56.0
10.82
8.66
7.08
5.74
4.63
3.76
3.13
2.73
o
56.0
10.06
8.08
6.62
5.37
4.35
3.55
2.97
2.61
35 C
30 C
25 C
20 C
15 C
Indoor air temperature conditions : 27.0
Heating
dry-bulb / 19.0
Compressor + Oudoor Fan
wet bulb
9
Power consumption (kW)
Outdoor Outdoor
90%
80%
70%
60%
50%
40%
30%
Unit 100% 100%
Unit
Dry-Bulb Heating Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity
Capacity
( C)
(kW)
63.0
14.34
11.86
9.85
8.10
6.59
5.33
4.32
3.56
15 C
o
o
o
11 C
63.0
15.46
12.71
10.51
8.57
6.91
5.53
4.41
3.57
o
7C
63.0
16.46
13.48
11.10
9.01
7.22
5.72
4.51
3.60
o
1C
58.6
16.74
13.68
11.24
9.09
7.25
5.71
4.47
3.53
o
50.4
15.55
12.74
10.47
8.49
6.79
5.36
4.21
3.35
42.8
13.98
11.50
9.49
7.72
6.21
4.94
3.93
3.16
-5 C
o
-10 C
Indoor air temperature conditions : 20.0
dry-bulb
77
Part Load Performance
MMY-AP2601 (26HP, 73kW system)
Cooling
Compressor + Oudoor Fan
Power consumption (kW)
Outdoor Outdoor
90%
80%
70%
60%
50%
40%
30%
Unit 100% 100%
Unit
Capacity
Capacity
Capacity
Capacity
Capacity
Capacity
Capacity
Capacity
Cooling
Dry-Bulb
( C)
Capacity
(kW)
40 C
67.9
21.47
16.76
13.56
10.83
8.57
6.78
5.45
4.60
o
o
o
73.0
20.29
15.84
12.81
10.22
8.07
6.37
5.11
4.29
o
73.0
16.79
13.21
10.74
8.64
6.90
5.53
4.52
3.88
o
73.0
15.04
11.88
9.70
7.83
6.30
5.09
4.20
3.65
o
73.0
13.98
11.08
9.06
7.34
5.93
4.81
4.00
3.49
o
73.0
13.00
10.34
8.47
6.88
5.58
4.55
3.81
3.34
35 C
30 C
25 C
20 C
15 C
Indoor air temperature conditions : 27.0
9
Heating
dry-bulb / 19.0
Compressor + Oudoor Fan
wet bulb
Power consumption (kW)
Outdoor Outdoor
90%
80%
70%
60%
50%
40%
30%
Unit 100% 100%
Unit
Dry-Bulb Heating Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity
Capacity
( C)
(kW)
81.5
17.87
14.73
12.25
10.08
8.21
6.66
5.41
4.47
15 C
o
o
o
11 C
81.5
19.26
15.79
13.06
10.67
8.62
6.90
5.52
4.48
o
7C
81.5
20.51
16.75
13.80
11.21
8.99
7.14
5.64
4.52
o
1C
75.8
20.86
16.99
13.97
11.31
9.03
7.12
5.59
4.43
o
65.2
19.37
15.82
13.02
10.57
8.46
6.69
5.27
4.20
55.4
17.42
14.29
11.80
9.62
7.74
6.18
4.92
3.96
-5 C
o
-10 C
Indoor air temperature conditions : 20.0
78
dry-bulb
Part Load Performance
MMY-AP3001 (30HP, 84kW system)
Cooling
Compressor + Oudoor Fan
Power consumption (kW)
Outdoor Outdoor
90%
80%
70%
60%
50%
40%
30%
Unit 100% 100%
Unit
Capacity
Capacity
Capacity
Capacity
Capacity
Capacity
Capacity
Capacity
Cooling
Dry-Bulb
( C)
Capacity
(kW)
40 C
78.1
25.67
20.24
16.36
13.06
10.32
8.15
6.54
5.50
o
o
o
84.0
24.26
19.12
15.45
12.31
9.72
7.65
6.13
5.14
o
84.0
20.08
15.94
12.95
10.40
8.30
6.64
5.42
4.64
o
84.0
17.98
14.33
11.68
9.43
7.57
6.10
5.03
4.35
o
84.0
16.72
13.36
10.91
8.83
7.12
5.77
4.79
4.17
o
84.0
15.55
12.46
10.20
8.27
6.69
5.45
4.55
3.99
35 C
30 C
25 C
20 C
15 C
Indoor air temperature conditions : 27.0
Heating
dry-bulb / 19.0
Compressor + Oudoor Fan
wet bulb
9
Power consumption (kW)
Outdoor Outdoor
90%
80%
70%
60%
50%
40%
30%
Unit 100% 100%
Unit
Dry-Bulb Heating Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity
Capacity
( C)
(kW)
95.0
21.63
17.78
14.78
12.14
9.88
8.00
6.48
5.34
15 C
o
o
o
11 C
95.0
23.31
19.07
15.76
12.86
10.37
8.29
6.62
5.36
o
7C
95.0
24.82
20.22
16.65
13.52
10.83
8.58
6.77
5.40
o
1C
88.4
25.24
20.52
16.85
13.64
10.88
8.56
6.70
5.30
o
76.0
23.45
19.10
15.71
12.73
10.18
8.04
6.32
5.02
64.6
21.09
17.25
14.23
11.59
9.31
7.41
5.89
4.73
-5 C
o
-10 C
Indoor air temperature conditions : 20.0
dry-bulb
79
Part Load Performance
MMY-AP3411 (34HP, 96kW system)
Cooling
Compressor + Oudoor Fan
Power consumption (kW)
Outdoor Outdoor
90%
80%
70%
60%
50%
40%
30%
Unit 100% 100%
Unit
Capacity
Capacity
Capacity
Capacity
Capacity
Capacity
Capacity
Capacity
Cooling
Dry-Bulb
( C)
Capacity
(kW)
40 C
89.3
35.00
25.73
20.59
16.18
12.51
9.56
7.35
5.87
o
o
o
96.0
33.08
24.32
19.45
15.28
11.79
9.00
6.90
5.48
o
96.0
27.38
20.18
16.21
12.81
9.98
7.72
6.03
4.91
o
96.0
24.52
18.10
14.58
11.56
9.06
7.06
5.57
4.59
o
96.0
22.80
16.85
13.59
10.80
8.49
6.65
5.28
4.38
o
96.0
21.20
15.68
12.67
10.10
7.96
6.26
5.00
4.18
35 C
30 C
25 C
20 C
15 C
Indoor air temperature conditions : 27.0
9
Heating
dry-bulb / 19.0
Compressor + Oudoor Fan
wet bulb
Power consumption (kW)
Outdoor Outdoor
90%
80%
70%
60%
50%
40%
30%
Unit 100% 100%
Unit
Dry-Bulb Heating Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity
Capacity
( C)
(kW)
108.0
25.74
21.20
17.66
14.54
11.63
9.19
7.23
5.75
15 C
o
o
o
11 C
108.0
27.74
22.82
18.94
15.50
12.29
9.61
7.44
5.81
o
7C
108.0
29.54
24.28
20.08
16.37
12.90
10.00
7.66
5.89
o
100.4
30.04
24.68
20.38
16.56
13.01
10.03
7.62
5.80
86.4
27.90
22.95
18.97
15.44
12.15
9.39
7.17
5.48
73.4
25.10
20.68
17.13
13.99
11.07
8.61
6.64
5.14
1C
o
-5 C
o
-10 C
Indoor air temperature conditions : 20.0
80
dry-bulb
Part Load Performance
MMY-AP4001 (40HP, 112kW system)
Cooling
Compressor + Oudoor Fan
Power consumption (kW)
Outdoor Outdoor
90%
80%
70%
60%
50%
40%
30%
Unit 100% 100%
Unit
Capacity
Capacity
Capacity
Capacity
Capacity
Capacity
Capacity
Capacity
Cooling
Dry-Bulb
( C)
Capacity
(kW)
40 C
104.2
34.22
26.98
21.82
17.41
13.76
10.86
8.72
7.34
o
o
o
112.0
32.34
25.49
20.60
16.42
12.95
10.20
8.17
6.85
o
112.0
26.77
21.25
17.26
13.87
11.06
8.85
7.22
6.19
o
112.0
23.97
19.11
15.58
12.57
10.09
8.13
6.71
5.81
o
112.0
22.29
17.82
14.55
11.78
9.49
7.69
6.38
5.56
o
112.0
20.72
16.61
13.60
11.03
8.92
7.27
6.07
5.32
35 C
30 C
25 C
20 C
15 C
Indoor air temperature conditions : 27.0
Heating
dry-bulb / 19.0
Compressor + Oudoor Fan
wet bulb
9
Power consumption (kW)
Outdoor Outdoor
90%
80%
70%
60%
50%
40%
30%
Unit 100% 100%
Unit
Dry-Bulb Heating Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity
Capacity
( C)
(kW)
126.5
28.80
23.71
19.70
16.19
13.18
10.66
8.64
7.12
15 C
o
o
o
11 C
126.5
31.04
25.42
21.01
17.15
13.83
11.05
8.83
7.15
o
7C
126.5
33.05
26.96
22.20
18.02
14.44
11.44
9.03
7.20
o
1C
117.6
33.61
27.36
22.47
18.19
14.50
11.42
8.94
7.06
o
101.2
31.22
25.47
20.95
16.98
13.57
10.72
8.43
6.69
86.0
28.08
23.00
18.98
15.45
12.42
9.89
7.85
6.31
-5 C
o
-10 C
Indoor air temperature conditions : 20.0
dry-bulb
81
Part Load Performance
MMY-AP4801 (48HP, 135kW system)
Cooling
Compressor + Oudoor Fan
Power consumption (kW)
Outdoor Outdoor
90%
80%
70%
60%
50%
40%
30%
Unit 100% 100%
Unit
Capacity
Capacity
Capacity
Capacity
Capacity
Capacity
Capacity
Capacity
Cooling
Dry-Bulb
( C)
Capacity
(kW)
40 C
125.6
52.55
37.96
30.27
23.67
18.14
13.70
10.34
8.06
o
o
o
135.0
49.67
35.89
28.61
22.35
17.11
12.90
9.71
7.54
o
135.0
41.11
29.74
23.79
18.69
14.43
11.02
8.45
6.72
o
135.0
36.82
26.65
21.37
16.84
13.07
10.05
7.78
6.27
o
135.0
34.23
24.79
19.90
15.72
12.24
9.45
7.37
5.98
o
135.0
31.83
23.06
18.54
14.68
11.46
8.89
6.97
5.70
35 C
30 C
25 C
20 C
15 C
Indoor air temperature conditions : 27.0
9
Heating
dry-bulb / 19.0
Compressor + Oudoor Fan
wet bulb
Power consumption (kW)
Outdoor Outdoor
90%
80%
70%
60%
50%
40%
30%
Unit 100% 100%
Unit
Dry-Bulb Heating Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity
Capacity
( C)
(kW)
150.0
36.42
30.54
25.48
20.98
16.66
13.05
10.14
7.93
15 C
o
o
o
11 C
150.0
39.26
32.93
27.37
22.42
17.67
13.68
10.47
8.04
o
7C
150.0
41.80
35.07
29.06
23.72
18.59
14.28
10.81
8.17
o
1C
139.5
42.50
35.68
29.51
24.04
18.76
14.34
10.77
8.06
o
120.0
39.49
33.17
27.46
22.39
17.51
13.42
10.12
7.61
102.0
35.51
29.85
24.77
20.26
15.92
12.29
9.36
7.13
-5 C
o
-10 C
Indoor air temperature conditions : 20.0
82
dry-bulb
10
Wiring guideline
83
Foreword
84
10 Wiring guideline Foreword
WIRING DESIGN
1. General
(1) Perform wiring of the power supplies in conformance with the regulations of the local electrical authorities.
(2) Use a 2 core shielded wire for control wiring on connecting indoor units, and connecting of indoor units to
outdoor units. This is recommended to prevent possible noise issues.
(3) Be sure to connect an earth leakage breaker to the power supply of the indoor units.
(4) Supply a separate power supply to each outdoor unit ensuring use of an earth leakage breaker and isolator.
(5) Never connect 220_240V power to the terminal block (U1, U2, U3, U4, U5, U6)
(Fault will be caused.)
(6) Locate wiring system for the control and refrigerant piping system in the same line.
(7) Arrange the electrical cables so that they do not come in to contact with high-temperature parts of the pipework;
otherwise insulation will melt and an accident may be caused.
(8) Do not turn on the power supply of the indoor units until vacuuming of the refrigerant pipe has finished.
2. For outdoor unit power supply
Select the power supply cabling and fuse of each outdoor unit from the following specifications:
5 core cable in conformance with Design 60245 IEC 66
Do not connect the outdoor units by crossing outside of them,
but connect them via the terminal block
(L1, L2, L3, N).
Outdoor power supply
_
3-phase 380V 415, 50Hz
380V,
60Hz
L1 L2 L3
N
L1 L2 L3
N
L1 L2 L3
N
L1 L2 L3
N
3. Electrical wiring design
3-phase
50Hz 380-415V
or 60Hz 380V
10
Earth
Earth leakage breaker
hand switch
Outdoor
power source
Isolator box
Indoor
power source
Single phase
50Hz 220-240V
or 60Hz 220V
Earth leakage breaker
Power switch
Model
Outdoor power supply
MMY-AP
T8, HT8
3phase, 380_415 V, 50Hz
MMY-AP
HT7
3phase, 380 V, 60Hz
Unit capacities and power supply wire sizes (Reference)
MAP0501T8
MAP0601T8
MAP0801T8
MAP1001T8
MAP1201T8
Model
MMYMAP0501HT8
MAP0601HT8
MAP0801HT8
MAP1001HT8
MAP1201HT8
MAP0501HT7
MAP0601HT7
MAP0801HT7
MAP1001HT7
MAP1201HT7
Power supply wiring
Wire size
Field size
20 A
3.5mm2 (A WG #12) Max. 26 m
2
20 A
3.5mm (A WG #12) Max. 26 m
30 A
3.5mm2 (A WG #10) Max. 20 m
30 A
5.5mm2 (A WG #10) Max. 28 m
5.5mm2 (A WG #10) Max. 27 m
30 A
Determine the wire size for the indoor unit according to the number of connected indoor units downstream.
Observe local regulations in reference to the wire size selection and installation.
85
4. For Indoor unit power supply (Must be independent from the outdoor unit power supply.)
Power supply wiring
Item
Wire size
Model
All models of indoor units
2.0m2 (AWG#14)
Max. 20m
Field fuse
3.5m2 (AWG#12)
Max. 50m
15A
NOTE :
The above connecting lengths stated in the table, indicate the length from the isolator to the outdoor unit. When the
power supply of the indoor units are connected in parallel, it is assumed that no more than a 2% voltage drop will occur.
If the connecting length is to exceed the stated lengths, select a suitable wire in accordance with the local wiring standards.
CAUTIONS
(1) Keep the refrigerant piping system and the indoor-indoor/indoor-outdoor control wiring systems together.
(2) When running power supplies and control wires parallel to each other, either run them through separate conduits or
maintain a suitable distance between them.
(Current capacity of power supplies: 10A or less for 300m, 50A or less for 500m)
5. Design of
control wiring
Power supply
Single phase
220-240V 50Hz
220Hz ~ 60Hz
(Open)
Earth
[Central remote controller] (Option)
TCB-SC642TLE (For Line 64)
Communication wire for control
between outdoor units Communication wire for control between
outdoor unit and indoor unit
Connection of shield wire must be connected
(Connected to all connecting sections in each outdoor unit)
Connection of shield wire must be connected
(Connected to all connecting sections in each indoor unit)
10
Wired
remote controller
Wire specification, quantity, size of crossover wiring and remote controller wiring
Name
Crossover wiring
(indoor-indoor / indoor-outdoor / outdoor-indoor
control wiring, central control wiring)
Remote controller wiring
Qty
2 cores
2 cores
Up to 500m
Size
Up to 1000m
1.25mm2
0.5 to 2.0mm2
_
1000 to 2000m
Specification
2.0mm2
Shield wire
_
_
(1) The crossover wiring and central control wiring uses a 2-core non-polarity communication wire. Use 2-core shielded
wire to prevent possible noise issues. Connect the end of the shielded wires and earth(ground) at both the outdoor
and indoor unit. Where the shielded wire is connected between a central controller and a outdoor unit, only
earth(ground) at one end of the central control line.
(2) Use 2-core non-polarity wire for remote controller. (A, B terminals)
Use 2-core non-polarity wire for wiring of group control. (A, B terminals)
86
Foreword
6. Control wiring Diagram
1. All control wiring is 2-core non-polarity wire.
2. Be sure to use shield wire for the following wiring to prevent noise issues.
Outdoor-outdoor / indoor-indoor / outdoor-indoor control wiring, Central control wiring.
Central control
device
U1 U2
U3 U4
Super modular multi system
Header
unit
Header
unit
Table-1
L4
Follower
unit
Follower
unit
Follower
unit
Header
unit
Follower
unit
U3 U4
U3 U4
U3 U4
U3 U4
U3 U4
U3 U4
U3 U4
U1 U2 U5 U6
U1 U2 U5 U6
U1 U2 U5 U6
U1 U2 U5 U6
U1 U2 U5 U6
U1 U2 U5 U6
U1 U2 U5 U6
Outdoor unit
Table-1
L5
L1
Table-2
L2
Indoor unit
U1 U2
U1 U2
A B
U1 U2
A B
L3
U1 U2
A B
A B
U1 U2
U1 U2
A B
Table-3
A B
L7
Remote
controller
Remote controller
U1 U2
A B
Type
Size
Length
A B
L6
Remote controller
Table-1 Control wiring between indoor and outdoor units (L1, L2, L3),
Central control wiring (L4)
Wiring
U1 U2
10
2-core, non-polarity
Shield wire
1.25 m2 : Up to 1000 m
2.0 m2 : Up to 2000 m (*1)
Note (*1) : Total length of control wiring length for all refrigerant circuits ( L1 + L2 + L3 + L4 )
Table-2 Control wiring between outdoor units (L5)
Wiring
Type
Size
Length
2-core, non-polarity
Shield wire
1.25 m2 to 2.0 m2
Up to 100 m (L5)
Table-3 Remote controller wiring (L6, L7)
Wire
2-core
Size
0.5 m2
Length
to 2.0 m2
Up to 500 m ( L6 + L7)
Up 400m in case of wireless remote controller in group control.
Up to 200m total length of control wiring between indoor units ( L6 )
87
50Hz
Type
MMU-AP
MMU-AP
MMU-AP
MMU-AP
MMU-AP
MMU-AP
MMU-AP
MMU-AP
MMU-AP
MMU-AP
MMU-AP
2-Way Air
MMU-AP
Discharge
MMU-AP
Cassette Type
MMU-AP
MMU-AP
MMU-AP
MMU-AP
MMU-AP
MMU-AP
MMU-AP
1-Way Air
MMU-AP
Discharge
MMU-AP
Cassette Type
MMU-AP
MMU-AP
MMU-AP
MMD-AP
Concealed Duct Type MMD-AP
MMD-AP
MMD-AP
MMD-AP
MMD-AP
MMD-AP
MMD-AP
MMD-AP
MMD-AP
MMD-AP
MMD-AP
Concealed Duct
MMD-AP
High Static
MMD-AP
Pressure Type
MMD-AP
MMD-AP
MMD-AP
MMD-AP
MMC-AP
Under Ceiling Type
MMC-AP
MMC-AP
MMC-AP
MMC-AP
MMC-AP
MMK-AP
Hige Wall Type
MMK-AP
MMK-AP
MMK-AP
MMK-AP
MMK-AP
MML-AP
Floor Standing
MML-AP
Cabinet Type
MML-AP
MML-AP
MML-AP
MML-AP
MML-AP
Floor Standing
MML-AP
Concealed Type
MML-AP
MML-AP
MML-AP
MML-AP
MMF-AP
Floor Standing Type MMF-AP
MMF-AP
MMF-AP
MMF-AP
MMF-AP
MMF-AP
4-Way Air
Discharge
Cassette Type
10
88
Model
0091
0121
0151
0181
0241
0271
0301
0361
0481
0561
0071
0091
0121
0151
0181
0241
0271
0301
0481
0071
0091
0121
0151
0181
0241
0071
0091
0121
0151
0181
0241
0271
0301
0361
0481
0561
0181
0241
0271
0361
0481
0721
0961
0151
0181
0241
0271
0361
0481
0071
0091
0121
0151
0181
0241
0071
0091
0121
0151
0181
0241
0071
0091
0121
0151
0181
0241
0151
0181
0241
0271
0361
0481
0561
H
H
H
H
H
H
H
H
H
H
WH
WH
WH
WH
WH
WH
WH
WH
WH
YH
YH
YH
SH
SH
SH
BH
BH
BH
BH
BH
BH
BH
BH
BH
BH
BH
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
BH
BH
BH
BH
BH
BH
H
H
H
H
H
H
H
Nominal Voltage
(V-Ph-Hz)
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
220-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
Voltage Range
Min
Max
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
242
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
Fan Motor
kW
FLA
0.060
0.20
0.060
0.20
0.060
0.22
0.060
0.24
0.060
0.28
0.060
0.28
0.060
0.40
0.090
0.68
0.090
0.93
0.090
0.95
0.053
0.36
0.053
0.36
0.053
0.36
0.039
0.37
0.039
0.37
0.053
0.53
0.053
0.53
0.053
0.54
0.092
1.33
0.022
0.28
0.022
0.28
0.022
0.28
0.034
0.55
0.034
0.55
0.034
0.63
0.120
0.33
0.120
0.33
0.120
0.39
0.120
0.39
0.120
0.50
0.120
0.60
0.120
0.60
0.120
0.70
0.120
0.96
0.120
1.13
0.120
1.13
0.160
0.93
0.160
1.55
0.160
1.55
0.260
1.87
0.260
2.12
0.370 x 3
6.04
0.370 x 3
6.35
0.030
0.33
0.030
0.37
0.040
0.48
0.040
0.48
0.080
0.90
0.080
0.96
0.030
0.35
0.030
0.35
0.030
0.35
0.030
0.37
0.030
0.37
0.030
0.40
0.045
0.30
0.045
0.30
0.045
0.49
0.045
0.49
0.070
0.54
0.070
0.54
0.019
0.29
0.019
0.29
0.019
0.29
0.070
0.52
0.070
0.52
0.070
0.53
0.037
0.77
0.037
0.77
0.063
1.01
0.063
1.01
0.110
1.48
0.160
1.84
0.160
1.84
Power Supply
MCA
MOCP
0.25
15
0.25
15
0.28
15
0.30
15
0.35
15
0.35
15
0.50
15
0.85
15
1.16
15
1.19
15
0.45
15
0.45
15
0.45
15
0.46
15
0.46
15
0.66
15
0.66
15
0.68
15
1.67
15
0.35
15
0.35
15
0.35
15
0.69
15
0.69
15
0.79
15
0.41
15
0.41
15
0.49
15
0.49
15
0.62
15
0.75
15
0.75
15
0.88
15
1.20
15
1.41
15
1.41
15
1.16
15
1.94
15
1.94
15
2.34
15
2.65
15
7.55
15
7.94
15
0.41
15
0.46
15
0.60
15
0.60
15
1.13
15
1.20
15
0.44
15
0.44
15
0.44
15
0.46
15
0.46
15
0.50
15
0.37
15
0.37
15
0.62
15
0.62
15
0.68
15
0.68
15
0.36
15
0.36
15
0.36
15
0.65
15
0.65
15
0.66
15
0.96
15
0.96
15
1.27
15
1.27
15
1.85
15
2.30
15
2.30
15
60Hz
Type
Model
MMU-AP
MMU-AP
MMU-AP
MMU-AP
MMU-AP
MMU-AP
MMU-AP
MMU-AP
MMU-AP
MMU-AP
MMU-AP
MMU-AP
2-Way Air
MMU-AP
Discharge
MMU-AP
Cassette Type
MMU-AP
MMU-AP
MMU-AP
MMU-AP
MMU-AP
MMU-AP
1-Way Air
MMU-AP
Discharge
MMU-AP
Cassette Type
MMU-AP
MMU-AP
MMD-AP
Concealed Duct Type MMD-AP
MMD-AP
MMD-AP
MMD-AP
MMD-AP
MMD-AP
MMD-AP
MMD-AP
MMD-AP
MMD-AP
MMD-AP
MMD-AP
Concealed Duct
MMD-AP
High Static
MMD-AP
Pressure Type
MMD-AP
MMD-AP
MMD-AP
MMC-AP
MMC-AP
Under Ceiling Type
MMC-AP
MMC-AP
MMC-AP
MMC-AP
MMK-AP
Hige Wall Type
MMK-AP
MMK-AP
MMK-AP
MMK-AP
MMK-AP
MML-AP
Floor Standing
MML-AP
Cabinet Type
MML-AP
MML-AP
MML-AP
MML-AP
MML-AP
Floor Standing
MML-AP
Concealed Type
MML-AP
MML-AP
MML-AP
MML-AP
MMF-AP
Floor Standing Type
MMF-AP
MMF-AP
MMF-AP
MMF-AP
MMF-AP
MMF-AP
4-Way Air
Discharge
Cassette Type
0091
0121
0151
0181
0241
0271
0301
0361
0481
0561
0071
0091
0121
0151
0181
0241
0271
0301
0071
0091
0121
0151
0181
0241
0071
0091
0121
0151
0181
0241
0271
0301
0361
0481
0561
0181
0241
0271
0361
0481
0721
0961
0151
0181
0241
0271
0361
0481
0071
0091
0121
0151
0181
0241
0071
0091
0121
0151
0181
0241
0071
0091
0121
0151
0181
0241
0151
0181
0241
0271
0361
0481
0561
H
H
H
H
H
H
H
H
H
H
WH
WH
WH
WH
WH
WH
WH
WH
YH
YH
YH
SH
SH
SH
BH
BH
BH
BH
BH
BH
BH
BH
BH
BH
BH
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
BH
BH
BH
BH
BH
BH
H
H
H
H
H
H
H
Nominal Voltage
(V-Ph-Hz)
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
Voltage Range
Min
Max
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
Fan Motor
kW
FLA
0.060
0.21
0.060
0.21
0.060
0.23
0.060
0.25
0.060
0.29
0.060
0.29
0.060
0.42
0.090
0.70
0.090
0.98
0.090
1.00
0.053
0.38
0.053
0.38
0.053
0.38
0.039
0.44
0.039
0.44
0.053
0.61
0.053
0.61
0.053
0.67
0.022
0.30
0.022
0.30
0.022
0.30
0.034
0.62
0.034
0.62
0.034
0.70
0.120
0.35
0.120
0.35
0.120
0.41
0.120
0.41
0.120
0.52
0.120
0.63
0.120
0.63
0.120
0.73
0.120
1.00
0.120
1.18
0.120
1.18
0.160
1.06
0.160
2.07
0.160
2.07
0.260
2.38
0.260
2.60
0.370 x 3
8.17
0.370 x 3
8.53
0.030
0.35
0.030
0.39
0.040
0.50
0.040
0.50
0.080
0.94
0.080
1.00
0.030
0.37
0.030
0.37
0.030
0.37
0.030
0.39
0.030
0.39
0.030
0.40
0.045
0.29
0.045
0.29
0.045
0.51
0.045
0.51
0.070
0.61
0.070
0.61
0.019
0.31
0.019
0.31
0.019
0.31
0.070
0.53
0.070
0.53
0.070
0.59
0.037
0.77
0.037
0.77
0.063
1.04
0.063
1.04
0.110
1.58
0.160
2.01
0.160
2.01
Power Supply
MCA
MOCP
0.26
15
0.26
15
0.29
15
0.31
15
0.37
15
0.37
15
0.52
15
0.88
15
1.22
15
1.25
15
0.47
15
0.47
15
0.47
15
0.55
15
0.55
15
0.76
15
0.76
15
0.84
15
0.37
15
0.37
15
0.37
15
0.78
15
0.78
15
0.88
15
0.43
15
0.43
15
0.51
15
0.51
15
0.65
15
0.78
15
0.78
15
0.91
15
1.25
15
1.48
15
1.48
15
1.32
15
2.59
15
2.59
15
2.98
15
3.25
15
10.2
15
10.7
15
0.43
15
0.48
15
0.63
15
0.63
15
1.18
15
1.25
15
0.46
15
0.46
15
0.46
15
0.48
15
0.48
15
0.50
15
0.36
15
0.36
15
0.63
15
0.63
15
0.76
15
0.76
15
0.39
15
0.39
15
0.39
15
0.66
15
0.66
15
0.73
15
0.96
15
0.96
15
1.29
15
1.29
15
1.97
15
2.52
15
2.52
15
10
89
90
Nominal
Voltage
(V-Ph-Hz)
400-3-50
400-3-50
400-3-50
400-3-50
400-3-50
Legend
AP1401HT8
AP1601HT8
AP1801HT8
AP2001HT8
AP2201HT8
AP2211HT8
AP2401HT8
AP2411HT8
AP2601HT8
AP2801HT8
AP3001HT8
AP3201HT8
AP3211HT8
AP3401HT8
AP3411HT8
AP3601HT8
AP3611HT8
AP3801HT8
AP4001HT8
AP4201HT8
AP4401HT8
AP4601HT8
AP4801HT8
MCA
MOCP
ICF
RLA
400-3-50
400-3-50
400-3-50
400-3-50
400-3-50
400-3-50
400-3-50
400-3-50
400-3-50
400-3-50
400-3-50
400-3-50
400-3-50
400-3-50
400-3-50
400-3-50
400-3-50
400-3-50
400-3-50
400-3-50
400-3-50
400-3-50
400-3-50
Voltage
Range
Min Max
342
457
342
457
342
457
342
457
342
457
342
457
342
457
342
457
342
457
342
457
342
457
342
457
342
457
342
457
342
457
342
457
342
457
342
457
342
457
342
457
342
457
342
457
342
457
Voltage
Range
Min Max
342
457
342
457
342
457
342
457
342
457
LRA
Unit No.1
RLA
LRA
_
5.2 + 5.2
_
5.2 + 5.2
_
6.5 + 6.5
_
6.5 + 6.5
_
5.2 + 5.2
_
9.5 + 9.5
_
5.2 + 5.2
_
9.5 + 9.5
_
6.5 + 6.5
_
6.5 + 6.5
_
6.5 + 6.5
_
5.2 + 5.2
_
9.5 + 9.5
_
6.5 + 6.5
_
9.5 + 9.5
_
6.5 + 6.5
_
9.5 + 9.5
_
6.5 + 6.5
_
6.5 + 6.5
_
9.5 + 9.5
_
9.5 + 9.5
_
9.5 + 9.5
_
9.5 + 9.5
RLA
4.0 + 4.0
4.6 + 4.6
5.2 + 5.2
6.5 + 6.5
9.5 + 9.5
: Minimum Circuit Amps
: Maximum Overcurrent Protection (Amps)
: Maximum Instantaneous Current Flow Start
: Rated Load Amps
AP1401T8
AP1601T8
AP1801T8
AP2001T8
AP2201T8
AP2211T8
AP2401T8
AP2411T8
AP2601T8
AP2801T8
AP3001T8
AP3201T8
AP3211T8
AP3401T8
AP3411T8
AP3601T8
AP3611T8
AP3801T8
AP4001T8
AP4201T8
AP4401T8
AP4601T8
AP4801T8
Heat Pump
Nominal
Cooling
Model
Only model Voltage
MMY(V-Ph-Hz)
MMY-
Combination of outdoor unit
Heat Pump
Cooling
Model
Only model
MMYMMYMAP0501HT8 MAP0501T8
MAP0601HT8 MAP0601T8
MAP0801HT8 MAP0801T8
MAP1001HT8 MAP1001T8
MAP1201HT8 MAP1201T8
Single outdoor unit
Compressor
LRA
FLA
kW
Unit No.4
RLA
LRA
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
5.2 + 5.2
_
_
_
5.2 + 5.2
_
_
_
5.2 + 5.2
_
_
_
5.2 + 5.2
_
6.5 + 6.5
_
6.5 + 6.5
_
6.5 + 6.5
_
6.5 + 6.5
_
9.5 + 9.5
: Locked Rotor Amps
: Full Load Amps
: Fan Motor Rated Output (kW)
Compressor
Unit No.2
Unit No.3
RLA
LRA
RLA
LRA
_
_
_
4.6 + 4.6
_
_
_
5.2 + 5.2
_
_
_
5.2 + 5.2
_
_
_
6.5 + 6.5
_
_
5.2 + 5.2
4.6 + 4.6
_
_
_
6.5 + 6.5
_
_
5.2 + 5.2
5.2 + 5.2
_
_
_
9.5 + 9.5
_
_
5.2 + 5.2
5.2 + 5.2
_
_
6.5 + 6.5
5.2 + 5.2
_
_
6.5 + 6.5
6.5 + 6.5
_
_
5.2 + 5.2
5.2 + 5.2
_
_
6.5 + 6.5
6.5 + 6.5
_
_
5.2 + 5.2
5.2 + 5.2
_
_
9.5 + 9.5
6.5 + 6.5
_
_
6.5 + 6.5
5.2 + 5.2
_
_
9.5 + 9.5
9.5 + 9.5
_
_
6.5 + 9.5
6.5 + 6.5
_
_
6.5 + 6.5
6.5 + 6.5
_
_
6.5 + 6.5
6.5 + 6.5
_
_
9.5 + 9.5
6.5 + 6.5
_
_
9.5 + 9.5
9.5 + 9.5
_
_
9.5 + 9.5
9.5 + 9.5
10
kW
0.6 x 2
0.6 x 2
0.6 x 2
0.6 x 2
0.6 x 3
0.6 x 2
0.6 x 3
0.6 x 2
0.6 x 3
0.6 x 3
0.6 x 3
0.6 x 4
0.6 x 3
0.6 x 4
0.6 x 3
0.6 x 4
0.6 x 3
0.6 x 4
0.6 x 4
0.6 x 4
0.6 x 4
0.6 x 4
0.6 x 4
kW
0.60
0.60
0.60
0.60
0.60
o
o
o
MCA MOCP ICF
_
36.5
40
_
40.0
50
_
42.5
50
_
45.0
60
_
56.5
70
_
47.0
60
_
60.0
70
_
49.0
60
_
62.5
70
_
65.0
80
_
67.5
80
_
80.0
90
_
69.5
80
_
82.5
100
_
71.5
80
_
85.0
100
_
73.5
90
_
87.5
100
_
90.0
100
_
92.0
110
_
94.0
110
_
96.0
110
_
98.0
110
Power Supply
MCA MOCP ICF
_
16.5
20
_
16.5
20
_
20.0
30
_
22.5
30
_
24.5
30
Power Supply
NOTE :
RLA is based on the following conditions.
Indoor temperature : 27 C DB/19 C WB
Outdoor temperature : 35 C DB
FLA
1.0 + 0.8
1.0 + 1.0
1.0 + 1.1
1.1 + 1.1
1.0 + 1.0 + 0.8
1.1 + 1.1
1.0 + 1.0 + 1.0
1.1 + 1.1
1.1 + 1.1 + 1.0
1.1 + 1.1 + 1.0
1.1 + 1.1 + 1.1
1.0 + 1.0 + 1.0 + 1.0
1.1 + 1.1 + 1.1
1.1 + 1.0 + 1.0 + 1.0
1.1 + 1.1 + 1.1
1.1 + 1.1 + 1.0 + 1.0
1.1 + 1.1 + 1.1
1.1 + 1.1 + 1.1 + 1.0
1.1 + 1.1 + 1.1 + 1.1
1.1 + 1.1 + 1.1 + 1.1
1.1 + 1.1 + 1.1 + 1.1
1.1 + 1.1 + 1.1 + 1.1
1.1 + 1.1 + 1.1 + 1.1
Fan Motor
FLA
0.8
0.8
1.0
1.1
1.1
Fan Motor
50Hz
380-3-60
380-3-60
380-3-60
380-3-60
380-3-60
MAP0501HT7
MAP0601HT7
MAP0801HT7
MAP1001HT7
MAP1201HT7
MCA
MOCP
ICF
RLA
Voltage
Range
Min Max
342
418
342
418
342
418
342
418
342
418
342
418
342
418
342
418
342
418
342
418
342
418
342
418
342
418
342
418
342
418
342
418
342
418
342
418
342
418
342
418
342
418
342
418
342
418
LRA
FLA
kW
Unit No.4
RLA
LRA
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
5.4 + 5.4
_
_
_
5.4 + 5.4
_
_
_
5.4 + 5.4
_
_
_
5.4 + 5.4
_
6.9 + 6.9
_
6.9 + 6.9
_
6.9 + 6.9
_
6.9 + 6.9
_
10.0 + 10.0
: Locked Rotor Amps
: Full Load Amps
: Fan Motor Rated Output (kW)
Unit No.3
RLA
LRA
_
_
_
_
_
_
_
_
_
4.8 + 4.8
_
_
_
5.4 + 5.4
_
_
_
5.4 + 5.4
_
5.4 + 5.4
_
6.9 + 6.9
_
5.4 + 5.4
_
6.9 + 6.9
_
5.4 + 5.4
_
6.9 + 6.9
_
5.4 + 5.4
_
10.0 + 10.0
_
6.9 + 6.9
_
6.9 + 6.9
_
6.9 + 6.9
_
6.9 + 6.9
_
10.0 + 10.0
_
10.0 + 10.0
Compressor
Compressor
Unit No.2
RLA
LRA
_
4.8 + 4.8
_
5.4 + 5.4
_
5.4 + 5.4
_
6.9 + 6.9
_
5.4 + 5.4
_
6.9 + 6.9
_
5.4 + 5.4
_
10.0 + 10.0
_
5.4 + 5.4
_
6.9 + 6.9
_
6.9 + 6.9
_
5.4 + 5.4
_
6.9 + 6.9
_
5.4 + 5.4
_
10.0 + 10.0
_
6.9 + 6.9
_
10.0 + 10.0
_
6.9 + 9.9
_
6.9 + 6.9
_
6.9 + 6.9
_
10.0 + 10.0
_
10.0 + 10.0
_
10.0 + 10.0
: Minimum Circuit Amps
: Maximum Overcurrent Protection (Amps)
: Maximum Instantaneous Current Flow Start
: Rated Load Amps
380-3-60
380-3-60
380-3-60
380-3-60
380-3-60
380-3-60
380-3-60
380-3-60
380-3-60
380-3-60
380-3-60
380-3-60
380-3-60
380-3-60
380-3-60
380-3-60
380-3-60
380-3-60
380-3-60
380-3-60
380-3-60
380-3-60
380-3-60
AP1401HT7
AP1601HT7
AP1801HT7
AP2001HT7
AP2201HT7
AP2211HT7
AP2401HT7
AP2411HT7
AP2601HT7
AP2801HT7
AP3001HT7
AP3201HT7
AP3211HT7
AP3401HT7
AP3411HT7
AP3601HT7
AP3611HT7
AP3801HT7
AP4001HT7
AP4201HT7
AP4401HT7
AP4601HT7
AP4801HT7
Legend
Nominal
Voltage
(V-Ph-Hz)
Heat Pump
Model
MMY-
LRA
Unit No.1
RLA
LRA
_
5.4 + 5.4
_
5.4 + 5.2
_
6.9 + 6.9
_
6.9 + 6.9
_
5.4 + 5.4
_
10.0 + 10.0
_
5.4 + 5.4
_
10.0 + 10.0
_
6.9 + 6.9
_
6.9 + 6.9
_
6.9 + 6.9
_
5.4 + 5.4
_
10.0 + 10.0
_
6.9 + 6.9
_
10.0 + 10.0
_
6.9 + 6.9
_
10.0 + 10.0
_
6.9 + 6.9
_
6.9 + 6.9
_
10.0 + 10.0
_
10.0 + 10.0
_
10.0 + 10.0
_
10.0 + 10.0
Voltage
Range
Min
RLA
Max
342
418
4.2 + 4.2
342
418
4.8 + 4.8
342
418
5.4 + 5.4
342
418
6.9 + 6.9
342
418 10.0 + 10.0
Combination of outdoor unit
Nominal
Voltage
(V-Ph-Hz)
Heat Pump
Model
MMY-
Single outdoor unit
10
91
kW
0.6 x 2
0.6 x 2
0.6 x 2
0.6 x 2
0.6 x 3
0.6 x 2
0.6 x 3
0.6 x 2
0.6 x 3
0.6 x 3
0.6 x 3
0.6 x 4
0.6 x 3
0.6 x 4
0.6 x 3
0.6 x 4
0.6 x 3
0.6 x 4
0.6 x 4
0.6 x 4
0.6 x 4
0.6 x 4
0.6 x 4
kW
0.60
0.60
0.60
0.60
0.60
FLA
0.8
1.0
1.1
1.1
1.0 + 0.8
1.1
1.0 + 1.0
1.1
1.1 + 1.0
1.1 + 1.0
1.1 + 1.1
1.0 + 1.0 +
1.1 + 1.1
1.0 + 1.0 +
1.1 + 1.1
1.1 + 1.0 +
1.1 + 1.1
1.1 + 1.1 +
1.1 + 1.1 +
1.1 + 1.1 +
1.1 + 1.1 +
1.1 + 1.1 +
1.1 + 1.1 +
1.0
1.1
1.1
1.1
1.1
1.1
1.0
1.0
1.0
MCA
36.5
40.0
42.5
45.0
56.5
47.0
60.0
49.0
62.5
65.0
67.5
80.0
69.5
82.5
71.5
85.0
73.5
87.5
90.0
92.0
94.0
96.0
98.0
o
o
ICF
_
_
_
_
_
o
MOCP
40
50
50
60
70
60
70
60
70
80
80
90
80
100
80
100
90
100
100
110
110
110
110
ICF
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
Power Supply
MCA MOCP
16.5
20
16.5
20
20.0
30
22.5
30
24.5
30
Power Supply
NOTE :
RLA is based on the following conditions.
Indoor temperature : 27 C DB/19 C WB
Outdoor temperature : 35 C DB
1.0 +
1.0 +
1.0 +
1.1 +
1.0 +
1.1 +
1.0 +
1.1 +
1.1 +
1.1 +
1.1 +
1.0 +
1.1 +
1.1 +
1.1 +
1.1 +
1.1 +
1.1 +
1.1 +
1.1 +
1.1 +
1.1 +
1.1 +
Fan Motor
FLA
0.8
0.8
1.0
1.1
1.1
Fan Motor
60Hz
10
92
11
Wiring diagram
93
Foreword
94
R(L) S(N)
Closed end
connector
RED
WHI
Symbol
FM
TA
TC1
TCJ
TC2
LM1, LM2
DM
FS
RY302
PMV
Parts name
1 1
2 2
3 3
CN44 1
(BLN) 2
CN66 1
(WHI) 2
BLK
1 1
CN67
(BLK) 2 2
3 3
WHI
RED
1
CN304
(GRY) 2
3
BLK : BLACK
GRY : GRAY
PNK : PINK
ORN : ORANGE
GRN : GREEN
Fan motor
Indoor temp sensor
Temp sensor
Temp sensor
Temp sensor
Lover motor
Drain pump motor
Float switch
Drain control relay
Pulse Motor Valve
RED : RED
WHI : WHITE
YEL : YELLOW
BLU : BLUE
BRN : BROWN
Color identification
Power supply
Single phase
220-240V 50Hz
220V 60Hz
Earth screw
Indoor unit
Flow selector
unit earth
screw
DM
CN68
(BLU)
indicates the terminal number.
CN60
(WHI)
3.
indicates the control P.C. board.
Power
supply
circuit
Outdoor unit
U1 U2
(Option)
Wired remote
controller
1 2
1 2
CN1
(WHI)
BLK
A B
WHI
U1 U2
1 2 3 4 5
CN81
(BLK)
DC20V
DC15V
DC12V
DC7V
1 2
1 2
CN001
(WHI)
BLK
Adaptor for wireless
remote controller
WHI
WHI
BLK
1 2 3
1 2 3
CN41
(BLU)
1 2
1 2
CN40
(BLU)
TR
CN02
(BLU)
3 3
2 2
1 1
1 1
2 2
1 1
2 2
1 1
2 2
3 3
1
2 PNL
3
1 EXCT
2
CN102
(RED)
CN101
(BLK)
CN100
(BRN)
CN80
(GRN)
CN73
(RED)
1 2 3 4 5
MCC-1401
X Y
TA
1 Filter input
2
TC1
TC2
TCJ
1 1
2 2
CN104
(YEL)
CN20 CN70
(BLU) (WHI)
1 2 CN03
1 2 (RED)
Network
adaptor
P.C. board
FS
3
1 CN34
3 2 1 (RED)
CN01 1 2 Network adaptor
(WHI) 1 2 (Option)
1 2 3
1 2 3
CN309
(YEL)
Indoor control P.C. board
MCC-1402
1 2 3 4 5 CN33
1 2 3 4 5 (WHI)
LM1
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
LM2
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5 6 CN82
1 2 3 4 5 6 (BLU)
1 2 3 4 5 6
Fuse
T3.15A
250V~
indicates the terminal block, the letter inside
(Fandrive)
1 2
CN61
(YEL)
T10 1 2 3 4 5 6
Ð
~
CN32
(WHI)
+
~
Motor drive
circuit
PMV
6 4 3 1 2 5
6 4 3 1 2 5
2. A dotted line and broken line indicate the wiring on site.
1.
1 2 3 4 5
CN50
(WHI)
P301
Fuse
T6.3A
250V~
RY303
RY302
5 4 3 2 1 CN334 1 2 3 4 5 CN333
5 4 3 2 1 (BLU) 1 2 3 4 5 (WHI)
FM
BLU
BLU
BLK
60Hz 380V
BLK
11 Wiring diagram
Foreword
1. Indoor Unit
1-1. 4-way Air Discharge Cassette Type
Model: MMU-AP0091H, AP0121H, AP0151H, AP0181H, AP0241H,
MMU-AP0271H, AP0301H, AP0361H, AP0481H, AP0561H
11
95
Power supply
Single phase
220-240V 50Hz
220V 60Hz
Closed end
connector
Flow selector
unit earth
screw
Indoor unit
Earth screw R(L) S(N)
RED : RED
WHI : WHITE
YEL : YELLOW
BLU : BLUE
BLK : BLACK
GRY : GRAY
PNK : PINK
ORN :ORANGE
BRN : BROWN
GRN : GREEN
Color
indication
FM
1
(BLK)
CN044 1
(BRW) 2
Outdoor unit
U1 U2
CN1
(WHI)
1 2
1 2
Remote controller
U1 U2
BLK
RC
YEL
BLU
L
1 2 3 4 5
RY005
RY006
M
CN050
(WHI)
H
1 2 3
1 2 3
CN074
(WHI)
RY002
UL
DP
1 2
1 2
LM
FS
FS
Sub P.C. board
MCC-1520
1 2 3 4 5 6 CN02
1 2 3 4 5 6 (YEL)
CN075
(WHI)
1 2 3 4 5 6
CN061
(YEL)
1 2 3 4 5 6 CN01
1 2 3 4 5 6 (WHI)
PMV
1
2 PNL
3
1 EXCT
2
1 1
2 2
CN080
(GRN)
CN073
(RED)
CN070
(WHI)
CN060
(WHI)
Parts name
Fan motor
Running capacitor
Transformer
Louver motor
Indoor temp sensor
Temp sensor
Louver control relay
Drain control relay
Heater control relay
Fan motor control relay
Float switch
Drain pump motor
Pulse Motor Valve
Option
1 2 3 4 5 6
Fan drive
1 2
CN032
(WHI)
1 1
2 2
3 3
CN100
(BRW)
1
2
3
4
5
1 1
2 2
CN101
(BLK)
CN081
(BLK)
1 1
2 2
CN102
(RED)
TA
Filter
TC1
TC2
TCJ
1 1
2 2
CN104
(YEL)
1 2 3 4 5 6 (BLU)
1 2 3 4 5 6 CN082
6 4 3 1 2 5
6 4 3 1 2 5
PMV
Indoor control P.C. board
1 2 3 4 5 6
1 2 3 4 5 6
Power supply
circuit
RY001
1 2 3 (BLU) 1 2 3 (GRN) 1 2 3 (RED)
1 2 3 CN068 1 2 3 CN033 1 2 3 CN030
DM
LM
Symbol
FM
Network
RC
CN01 1 2 adaptor
LM
(WHI) 1 2 (Option)
TR
3 3
TA
TR
1 1
2
TC1,TC2,TCJ
2 2
1 1
RY001
CN03
RY002
CN02
(RED)
(BLU) MCC-1401
RY004
1.
indicates the terminal block, the letter inside
RY005~007
indicates the terminal number.
FS
DM
2. A dotted line and broken line indicate the wiring on site.
PMV
3.
indicates the control P.C. board.
RY007
RED
FAN
9 8 7 6 5 4 3 2 1
CN083(WHI) 9 8 7 6 5 4 3 2 1
A B X Y
1 2 3
1 2 3
CN040 CN041
(BLU) (BLU)
1 2
1 2
Line Filter
TR
Fuse
T5.0A
RY004
P301
1 1
2 2 CN067 250V~
(BLK)
3 3
1 1
2 2
3 3
CN066 1
(WHI) 2
CN039
(YEL)
3
CN304
(GRY) 2
9
WHI
1
2
RED
3
4
5
6
7
BLU
BLU
ORN
96
BLK
11
BLK
1
2
3
4
5
6
7
1-2. 2-way Air Discharge Cassette Type
Model: MMU-AP0071WH, AP0091WH, AP0121WH, AP0151WH, AP0181WH,
MMU-AP0241WH, AP0271WH, AP0301WH, AP0481WH
RED : RED
WHI : WHITE
YEL : YELLOW
BLU : BLUE
BLK : BLACK
GRY : GRAY
PNK : PINK
ORN :ORANGE
BRN : BROWN
GRN : GREEN
Color
indication
WHI
RED
Power supply
Single phase
220-240V 50Hz
220V 60Hz
WHI
1 1
3
CN304
(GRY) 2
1
Heater
BLU
RY004
Line Filter
TR
BLU
1 2
1 2
Outdoor
unit
U1 U2
1 2
1 2
CN1
(WHI)
AI-NET
central control
terminal
A B X Y
1 2 3
1
3
Remote controller
U1 U2
BLU
1 2
1 2
YEL
BLU
ORN
BLK
RED
L
CN03
(RED)
1 1
2 2
3 2 1 CN02
3 2 1 (BLU)
Network
adaptor
P.C. board
Network
CN01 1 2 adaptor
(WHI) 1 2 (Option)
1 2 3 4 5
RY005
RY006
M
CN050
(WHI)
H
MCC-1401
RY007
DP
2 1
2 1
LM
LM
2 1
2 1
FS
FS
TR
1 2 3 4 5 6 CN01
1 2 3 4 5 6 (WHI)
Sub P.C. board
MCC-1520
1 2 3 4 5 6 CN02
1 2 3 4 5 6 (YEL)
1 2 3 4 5 6
1 2 3 4 5 6
CN075
(WHI)
1 2 3 4 5 6
CN061
(YEL)
3.
indicates the control P.C. board.
2. A dotted line and broken line indicate the wiring on site.
indicates the terminal number.
PMV
1 EXCT
2
1 1
Filter
2 2
CN080
(GRN)
CN073
(RED)
CN070
(WHI)
CN060
(WHI)
Symbol
FM
RC
TR
LM
TA
TC1,TCJ
RY001
RY002
RY004
RY005~007
FS
DM
PMV
Parts name
Fan motor
Running capacitor
Power transformer
Louver motor
Indoor temp sensor
Temp sensor
Flap motor control relay
Drain pump control relay
Heater control relay
Fan motor control relay
Float switch
Drain pump motor
Pulse Motor Valve
Option
1 2 3 4 5 6
Fan drive
1 2
CN032
(WHI)
1
2 PNL
3
1
2
3
4
5
1 1
2 2
3 3
CN100
(BRW)
CN081
(BLK)
1
2
CN101
(BLK)
TC1
TCJ
1 1
2 2
CN102
(RED)
TA
1 1
2 2
CN104
(YEL)
1 2 3 4 5 6 (BLU)
1 2 3 4 5 6 CN082
6 4 3 1 2 5
6 4 3 1 2 5
PMV
Indoor control P.C. board
indicates the terminal block, the letter inside
1 2 3
1 2 3
Power supply
circuit
RY001
1 2 3 (BLU) 1 2 3 (GRN) 1 2 3 (RED)
1 2 3 CN068 1 2 3 CN033 1 2 3 CN030
CN074
(WHI)
1.
DM
1 2 3
1 2 3
RY002
UL
FAN
9 8 7 6 5 4 3 2 1
CN083(WHI) 9 8 7 6 5 4 3 2 1
CN044 CN040 CN041
(BRW) (BLU) (BLU)
1 1
2 2 CN067 Fuse
(BLK) T5.0A
3 3
CN066 1
(WHI) 2
AC IN
3 3
CN309
(YEL) 2 2
Closed end
connector
Flow selector
unit earth
screw
Indoor unit
Earth screw R(L) S(N)
RED
CN301
(BLK)
BLU
RC
BLK
FM
BLU
1
2
3
4
5
6
BLK
1
2
3
4
5
6
1-3. 1-way Air Discharge Cassette Type (Compact type)
Model: MMU-AP0071YH, AP0091YH, AP0121YH
11
97
TR
EMG
CN066
(WHI)
1
2
CN044
(BRW)
1
2
3 3
3 3
AC IN
1 1
1 1
3
1
P301
BLK
3
4
5
6
Power supply
single phase
220-240V 50Hz
220V 60Hz
1 2
1 2
CN040
(BLU)
(BLK)
CN067
U1 U2
1 2
1 2
Outdoor unit
U1 U2
Closed-end
connector
FUSE
(YEL)
CN309
(GRY)
CN304
B
1 2
1 2
CN1
A
3 3
2
1 1
H
L
3
3
3
3
3.
1
1
1 2
1 2
LM
1 2 3 4 5 6 CN02
1 2 3 4 5 6 (YEL)
the letter inside indicates the terminal number.
indicates the control P.C. board.
the wiring on site.
TR
1 2 3 4 5 6 CN01
1 2 3 4 5 6 (WHI)
Sub P.C. board
MCC-1520
3 CN030
3 (RED)
CN061
(YEL)
1
2
CN070
(WHI)
OPTION
FAN
DRIVE
TC1
RED : RED
WHI : WHITE
YEL : YELLOW
BLU : BLUE
BLK : BLACK
GRY : GRAY
PNK : PINK
ORN :ORANGE
BRN : BROWN
GRN : GREEN
Color
indication
Parts name
Fan motor
Running capacitor
Transformer
Lover motor
Indoor temp sensor
Temp sensor
Louver control relay
Drain control relay
Fan motor control relay
Float switch
Drain pump motor
Pulse motor valve
1 2 3 4 5 6
CN060
(WHI)
1
2
3
4
5
1
EXCT
2
CN073
(RED)
CN081
(BLK)
1
2 PNL
3
CN080
(GRN)
FILTER
1 1
2
3 3
CN100
(BRW)
TC2
TCJ
TA
1 1
2 2
1 1
2 2
1 1
2 2
CN101
(BLK)
CN102
(RED)
CN104
(YEL)
PMV
1 2 3 4 5 6 CN082
1 2 3 4 5 6 (BLU)
6 4 3 1 2 5
6 4 3 1 2 5
PMV
1 2
CN032
(WHI)
Symbol
FM
RC
TR
LM
TA
TC1,TC2,TCJ
RY001
RY002
RY005~007
FS
DM
PMV
1 2 3 4 5 6
CN075
(WHI)
1 2 3 4 5 6
1 2 3 4 5 6
1
1
FS
FS
Control P.C. board
for Indoor unit
MCC-1403
3 CN033
3 (GRN)
LM
Power supply
circuit
RY001
DM
Indicates the terminal bolock,
MCC-1401
DM
2. A dotted line and broken line indicate
1.
X Y
1 2
1 2
CN03(RED)
CN02
(BLU)
CN074 1
(WHI) 1
RY002
CN068 1
(BLU) 1
Network Adapter
(Option)
UL
CN01(WHI)
1 2
1 2
1 2 3 4 5
CN050
(WHI)
RY005
RY006
M
Remote Controller
1 2 3 RC
1
3
RY007
RED BLK ORN BLU YEL
FAN
7
5
3
1
CN083 9
(WHI) 9
7
5
3
1
CN041
(BLU)
RY004
T5.0A 250V~
Line Filter
Flow selector
unit earth
screw
RC
R(L) S(N)
Indoor unit
earth screw
FM
BLU
1
BLU
98
BLK
11
BLK
1
2
3
4
5
6
Model: MMU-AP0151SH, AP0181SH, AP0241SH
R(L) S(N)
Outdoor unit
U1 U2
1
1 1
2 2
3 3
1 1
CN44 1
(BRW) 2
Ð
~
Adaputor for wired
remote controller
Wired remote
controller
CN001
(WHI)
BLK
CN50
(WHI)
5
5
FM
X Y
1 2 CN03
1 2 (RED)
Network
adaptor
P.C. board
(Signal output)
indicates the terminal number.
indicates the terminal block, the letter inside
1 2 3 4 5 6
1 2
CN60
(WHI)
(Fan drive)
CN32
(WHI)
3.
indicates the control P.C. board.
FS
Symbol
FM
TA
TC1,TC2,TCJ
DM
FS
RY302
PMV
Parts name
Fan motor
Indoor temp sensor
Indoor temp sensor
Drain pump motor
Float switch
Drain pump control relay
Pulse Motor Valve
BLK : BLACK
GRY : GRAY
PNK : PINK
ORN : ORANGE
GRN : GREEN
Color identification
1 2 3 4 5
1
2
1 EXCT
2
CN73
(RED)
TC1
TC2
CN80
(GRN)
CN20 CN70
(BLU) (WHI)
TA
TCJ
1
2 PNL
3
1 1
2 2
CN101
(BLK)
1 1
2 2
3 3
1 1
2 2
CN102
(RED)
CN100
(BRN)
1 1
2 2
CN104
(YEL)
3
1 CN34
3 2 1 (RED)
RED : RED
WHI : WHITE
YEL : YELLOW
BLU : BLUE
BRN : BROWN
1 2 3 4 5
CN81
(BLK)
2. A dotted line and broken line indicate the wiring on site.
1.
Network
CN01 1 2 adaptor
(WHI) 1 2 (Option)
3 3
2 2
1 1
CN61
(YEL)
Power
supply
circuit
DC20V
DC15V
DC12V
DC7V
CN33
1 2 3 4 5 (WHI)
Indoor control P.C. board
1 2 3 4 5 6 CN82
1 2 3 4 5 6 (BLU)
6 4 3 1 2 5
6 4 3 1 2 5
PMV
T10 1 2 3 4 5 6
250V~
Fuse
T3.15A
1 2 3 4 5
CN02
(BLU)
TR
1 2 3
1 2 3
+
CN309
(YEL)
3
3
1 2 3
1 2 3
Motor drive
circuit
CN333 1
(WHI) 1
1 1
~
1 2
1 2
WHI
WHI
BLK
1 2 3
1 2 3
CN41
(BLU)
CN334
(WHI)
1 2
1 2
CN40
(BLU)
P301
250V~
Fuse
T6.3A
RY302
1 2
1 2
CN1
(WHI)
BLK
A B
WHI
U1 U2
BLK
3 3
CN66 1
(WHI) 2
WHI
CN67
(BLK) 2 2
RED
3
CN304
(GRY) 2
Flow selector
unit earth
screw
Closed end
connector
WHI
Reactor
WHI
Indoor unit power supply
Single phase
220-240V 50Hz
220V 60Hz
Earth screw
Indoor unit
RED
1
3
1 2 2
DM
5 4
2 1
5 4 3 2 1
BLU
BLU
BLK
CN68
(BLU)
BLK
5 5
4 4
1-4. Concealed Duct Standard Type
Model: MMD-AP0071BH, AP0091BH, AP0121BH, AP0151BH, AP0181BH, AP0241BH
MMD-AP0271BH, AP0301BH, AP0361BH, AP0481BH, AP0561BH
11
99
Indoor unit
Earth screw
Closed
end
connector
WHI
RED
S(N)
F
CN067
(BLK)
RY007
1 2
1 2
4
43F1
3
5
43F1
1 2 3 4
1 2 3 4 GRY
FM
Remote controller
1 2
1 2
CN1
(WHI)
A B
1 2 3
1
3
RC
U1 U2
OC
U1 U2
EMG
1 2
CN044 CN040 CN041
(BRW) (BLU) (BLU)
Outdoor unit
YEL
Closed end
connector
Fuse
T5.0A
CN066
(WHI)
RED
RED 6
Flow selector
unit earth
screw
TR
1
2
1 1
2 2
3 3
RED
RC
L
3 3
2
1 1
F4
F3
F2
X Y
F1
WHI
MCC-1401
DP
LM
CN074
(WHI)
RY001
1 2 3
1 2 3
1 2
1 2
CN075 CN061
(WHI) (YEL)
CN032
(WHI)
CN060
(WHI)
CN082
(BLU)
TR
1 2 3 4 5 6 CN01
1 2 3 4 5 6 (WHI)
Sub P.C. board
MCC-1520
1 2 3 4 5 6 CN02
1 2 3 4 5 6 (YEL)
Motor over heating protection switch
WHI
GRY
RED
BLK
Wired for MMD-AP0481 only
(BRN Wire)
49F
ORN
BRN
BLU
5
2
1
3
4
6
Symbol
FM
RC
TR
TA
TC1,TC2,TCJ
RY005~007
RY001
RY002
PMV
F
43F1
Sold
DM
separately
FS
6
5
4
3
2
1
6
5
4
3
2
1
1
Filter
2
CN070
(WHI)
1
2
3
4
5
1 EXCT
2
CN073
(RED)
CN081
(BLK)
1
2 PNL
3
CN080
(GRN)
1 2 3 CN100
1 2 3 (BRN)
TC1
1 2 3 4 5 6 1 2 3 4 5 6 1 2 1 2 3 4 5 6
Option
1 2 3 4 5 6 T10
Fan drive
Power
supply
circuit
1 2
1 2
TC2
CN104 CN102 CN101
(YEL) (RED) (BLK)
1 2
1 2
TCJ
Indoor control P.C. board
FS
CN030
(RED)
1 2 3
1 2 3
TA
1.
indicates the terminal block, the letter inside indicates the terminal number.
2. A dotted line and broken line indicate the wiring on site.
3.
indicates the control P.C. board.
4. When installing a drain pump, Remove CN030 connector and connect float
switch.
5. A part is connected to the terminal block.
When a change is required due to the outside static pressure at site,
check the terminal No. and lead colour of the fan motor in the below diagram
and then change the lead wire as indicated by the arrow mark (
),
6. Pay attention when changing static pressure because the outside static pressure
of H tap in 50 or 60Hz.
Network adaptor
(Option)
1 2 CN03
1 2 (RED)
CN01 1 2
(WHI) 1 2
DP
1 2 3 (BLU) 1 2 3 (GRN)
1 2 3 CN068 1 2 3 CN033
RY002
UL
1 2 3 4 5
CN050
(WHI)
RY005
RY006
M
CN02
(BLU)
H
FAN
9 8 7 6
4
2
CN083(WHI) 9 8 7 6 5 4 3 2 1
7
RY004
P301
43F1
1 1
CN309
2 2 (YEL)
3 3
3
CN304
(GRY) 2
1
(BLK)
T10A,250V~
Power supply
Single phase
220-240V 50Hz
220V 60Hz
R(L)
RED
RED : RED
WHI : WHITE
YEL : YELLOW
BLU : BLUE
BLK : BLACK
GRY : GRAY
PNK : PINK
ORN :ORANGE
BRN : BROWN
GRN : GREEN
8
BLU
WHI
ORN
Color
indication
WHI
RED
GRY
WHI
RED
BLK
100
(Option)
11
BRN
Spark
killer
PMV
Parts name
Fan motor
Running capacitor
Transformer
Indoor temp sensor
Temp sensor
Fan motor control relay
Flap motor control relay
Drain control relay
Pulse Motor Valve
Fuse
Fan motor control relay
Drain pump motor
Float switch
5
2
1
3
4
6
1-5. Concealed Duct High Static Pressure Type
Model: MMD-AP0181H, AP0241H, AP0271H, AP0361H, AP0481H
Symbol
FM
RC
TR
TA
TC1,TC2,TC3
RY005~007
RY001
RY002
PMV
F1~3
43F1,43F2
DM
FS
R(L) S(N)
WHI
Power supply
single phase
220-240V 50Hz
220V 60Hz
Indoor unit
earth screw
RED
WHI
RED
Parts name
Fan motor
Running capacitor
Transformer
Indoor temp sensor
Temp sensor
Fan motor control relay
Louver control relay
Drain control relay
Pulse motor valve
Fuse for fan motor
Fan motor control relay
Drain pump motor
Float switch
RED : RED
WHI : WHITE
YEL : YELLOW
BLU : BLUE
BLK : BLACK
GRY : GRAY
PNK : PINK
ORN :ORANGE
BRN : BROWN
GRN : GREEN
Closed-end
connector
Motor over heating
protection switch
49F
Color
indication
WHI
GRY
RED
WHI
RED
7
WHI
8
AC IN
S.K
F3
F2
1
2
3 3
1 1
F1
WHI
RED
3 3
1 1
3
1
P301
(BLK)
43F1
3
FAN3
1 2 3 4 4P
1 2 3 4 (RED)
5
RED
FM3
RC
F1
ORW
F2
F3
X Y
F4
CN03(RED)
1 2
1 2
RY001
DP
3 CN068
3 (BLU) 1
CN074 1
(WHI) 1
4
6
43F2
MCC-1401
FAN2
1 2 3 4 4P
1 2 3 4 (BLU)
3
3
FM2
F1
ORW
RC
LM
CN033
3 (GRN)
Network Adapter
(Option)
CN01(WHI)
CN02
(BLU)
1 2
1 2
1 2 3 4 5
CN050
(WHI)
3 3
2
1 1
1
1
RY002
UL
1
1
Indicates the terminal bolock,
Letter on the inside indicates the terminal number.
2. A dotted line and broken line indicate
the wiring on site.
3.
indicate the control p.c. board.
4. When fitting a drain pump remove CN030
connector and connect float switch.
1.
Closed-end
connector
3
5
43F2
Outdoor unit
U1 U2
B
L
RY005
1 2
1 2
CN1
Remote Controller
RED
A
T10.0A, 250V~
5
M
H
3
3
RY006
5
5
7
7
1 2
1 2 3
1 2 CO 1
3 RC
CN041
(BLU)
RY007
U1 U2
Line Filter
1 2
EMG
TR
CN044 CN040
(BRW) (BLU)
CN066
(WHI)
CN067
(BLK)
T5.0A 250V~
FUSE
(YEL)
CN309
(GRY)
CN304
RY004
T10.0A, 250V~
T10.0A, 250V~
RED
RED
RED
Sold separately
WHI
BLK
YEL
BLU
ORN
8
S.K
WHI
8
BLU
43F2
BLU
43F1
BLK
Fan motor inside
wiring diagram
BLK
WHI
RED
GRY
WHI
RED
GRY
YEL
FAN
CN083 9
(WHI) 9
YEL
Spark Killer
BLU
7
ORN
WHI
RED
GRY
WHI
RED
GRY
7
YEL
6
1
1
3
3
F2
F3
43F1
PMV
FAN1
1 2 3 4 4P
1 2 3 4 (WHI)
FM1
F1
ORW
RC
F2
F3
F4
5. A Position is connected to the terminal block when there is a
change to static pressure. change the lead wire of arrow
position after checking the terminal number as per figure
and the lead wire's checking fan motor.
6. When setting to the high tap, take care as the static pressures
are different at50Hz and 60Hz.
F4
4
5
2
1
3
4
6
Terminal Fan motor Static pressure
Note
No.
wiring
Pa (mmAg)
F1
YEL
69(7)
F2
BLU
137(14)
Setting from factory
F3
ORN
196(20)
FAN
DRIVE
6
OPTION
1 2
CN060
(WHI)
1 2 3 4 5 6
CN032
(WHI)
6
5
4
3
2
1
CN082
(BLU)
5
2
1
3
4
6
1
2
3
4
5
CN081
(BLK)
6
5
4
3
2
1
1
FILTER
2
CN070
(WHI)
Control P.C. board
for Indoor unit
MCC-1403
1
EXCT
2
1
2 PNL
3
CN073
(RED)
CN100
(BRW) CN080
(GRN)
1
3
1 2 3
CN061
(YEL)
1 2 3 4 5 6 CN01
1 2 3 4 5 6 (YEL)
TR
1 2
1 2
TC1
1 2 3 4 5 6
1 2 3 4 5 6 CN02
1 2 3 4 5 6 (YEL)
Sub P.C. board
MCC-1520
1 2
1 2
1 2
1 2
TC2
CN104 CN102 CN101
(YEL) (RED) (BLK)
TCJ
TA
Control P.C. board
for Indoor unit
MCC-1403
CN030
(RED)
FS
CN075
(WHI)
1 2 3 4 5 6
1 2 3 4 5 6
Power supply
circuit
BLU
RED
ORN
WHI
RED
GRY
WHI
RED
GRY
DM
YEL
(Option)
BLU
RED
ORN
RED
Model: MMD-AP0721H, AP0961H
11
101
102
RED
WHI
Flow selector
unit earth
screw
3
CN304 1
(GRY) 2
1 1
2 2
3 3
CN41
(BLU)
CN40
(BLU)
CN66
(WHI)
Fuse
T6.3A
250V~
P301
RY303
RY302
BLK
Adpter for wireless
remote controller
CN001
(WHI)
BLK
WHI
BLK
1 2 3 4 5
Wired remote
controller
WHI
Ð
+
CN50
(WHI)
1 2
1 2
CN1
(WHI)
1 2 3
1 2 3
CN309
(YEL)
~
~
indicates the terminal number.
indicates the terminal block, the letter inside
X Y
1 2 CN03
1 2 (RED)
Network
adaptor
P.C. board
Option
1 2 3 4 5 6
CN60
(WHI)
DC20V
DC15V
DC12V
DC7V
3.
indicates the control P.C. board.
CN81
(BLK)
CN70
(WHI)
CN73
(RED)
CN80
(GRN)
CN100
(BRW)
TA
1 FILTER
2
BLK : BLACK
GRY : GRAY
PNK : PINK
ORN : ORANGE
GRN : GREEN
Parts name
Fan motor
Indoor temp sensor
Temp sensor
Louver motor
Drain control relay
Drain pump motor
Float switch
RED : RED
WHI : WHITE
YEL : YELLOW
BLU : BLUE
BRN : BROWN
TC1
TC2
TCJ
1 EXCT
2
1
2 PNL
3
1 1
2 2
3 3
1 1
2 2
1 1
2 2
CN102
(RED)
CN101
(BLK)
1 1
2 2
CN104
(YEL)
Color identification
GRL
FS
1
3 CN34
1 2 3 (RED)
1 2 3 4 5
CN20
(BLU)
Symbol
FM
TA
TC1,TC2,TCJ
LM
RY302
DM
Sold
separately
FS
1 2 3 4 5
2. A dotted line and broken line indicate the wiring on site.
1.
3 3
2 2
1 1
Network
CN01 1 2 adaptor
(WHI) 1 2 (Option)
CN02
(BLU)
TR
1 2
Fandrive
CN32
(WHI)
Power
supply
circuit
T10
CN61
(YEL)
Fuse
T3.15A
Indoor control P.C.
board
1 2 3 4 5 CN33
1 2 3 4 5 (WHI)
1 2 3 4 5 6 CN82
1 2 3 4 5 6 (BLU)
LM
1 2 3 4 5
1 2 3 4 5
PMV
6 4 3 1 2 5
6 4 3 1 2 5
1 2 3 4 5 6
Motor drive
circuit
5 4
1 CN334 1 2 3 4 5 CN333
5 4 3 2 1 (WHI) 1 2 3 4 5 (WHI)
1 2
1 2
WHI
U1 U2 A B
1 1
2
BLK
3 3
BLK
2 2
BLU
1 1
BLU
1
2
BLK
1 1
CN67
(BLK) 2 2
3 3
Outdoor unit
U1 U2
Closed end
terminal
RED
WHI
Power supply
single phase
200-240V 50Hz
200V 60Hz
R(L) S(N)
Earth screw
Indoor unit
DM
CN68
(BLU)
11
FM
1-6. Under Ceiling Type
Model: MMC-AP0151H, AP0181H, AP0241H, AP0271H, AP0361H, AP0481H
RED : RED
WHI : WHITE
YEL : YELLOW
BLU : BLUE
BLK : BLACK
GRY : GRAY
PNK : PINK
ORN :ORANGE
BRN : BROWN
GRN : GREEN
Color
indication
Earth screw
Indoor unit
Power supply
single phase
220-240V 50Hz
220V 60Hz
R(L) S(N)
Outdoor
unit
X
GRY
1 2
1 2
CN001
(WHI)
BLK
Wired remote Adapter for
controller wireless remote
controller
1 2
1 2
CN1
(WHI)
Y
GRY
BLK
BLK
BLK
WHI
1 2 3
1
3
1 2
1 2
BLU
BLU
CN41
(BLU)
CN40
(BLU)
T6.3A 250V~
FUSE
RY303
RY302
BLK WHI
B
CN66
(WHI)
1
2
P301
BLK
3 3
CN67
(BLK)
1 1
3 3
CN304
(GRY)
A
WHI
U1 U2
U1 U2
RED
Closed-end
connector
WHI
Flow selector
unit earth
screw
WHI
RED
LM
3
1
1 1
CN68
(BLU)
1
1
CN334 5 4
2 1
(WHI) 5 4 3 2 1
5
5
1 2
1 2
CN03(RED)
CN01(WHI)
CN02
(BLU)
1 2
1 2
1 2 3 4 5
CN50
(WHI)
PMV
3
3
1 1
2 2
TC2
Option
1 2 3 4 5
CN81
(BLK)
1 2 3 4 5
CN20
(BLU)
Symbol
FM
TA
TC1,TC2,TCJ
PMV
LM
RY303
1
2
CN70
(WHI)
Parts name
Fan motor
Indoor temp sensor
Temp sensor
Pulse motor valve
Lover motor
Louver control relay
indicates the control P.C. board.
the wiring on site.
2. A dotted line and broken line indicate
3.
1
2 EXCT
CN73
(RED)
the letter inside indicates the terminal number.
1
2
3
1
2
CN080
(GRN)
CN100
(BRW)
CN103
(GRN)
1
3
1 2 3
TC1
Indicates the terminal bolock,
1 2 3 4 5 6
1 2
Fandrive
1 2 3 4 5 6
1.
1 1
2 2
TCJ
CN104 CN102 CN101
(YEL) (RED) (BLK)
1 1
2 2
TA
Control P.C. board
for Indoor unit
MCC-1402
CN32
(WHI)
CN60
(WHI)
DC20V
DC15V
DC12V
DC7V
CN34
(RED)
1
1
CN61
(YEL)
T3.15A 250V~
Power
supply
circuit
CN33
(WHI)
CN82
(BLU)
FUSE
1 2 3 4 5
1 2 3 4 5 6
1 2 3 4 5 6
6 4 3 1 2 5
6 4 3 1 2 5
Network Adapter
(Option)
MCC-1401
3 3
2
1 1
TR
3 CN309
3 (YEL)
3
3
1 2 3
1 2 3
FM
Motor drive
circuit
CN333 1
(WHI) 1
1 1
5 5
4 4
1-7. High Wall Type
Model: MMK-AP0071H, AP0091H, AP0121H, AP0151H, AP0181H, AP0241H
11
103
TR
CN066
(WHI)
1 1
2 2
RED
Closed-end
connector
WHI
Power supply
single phase
220-240V 50Hz
220V 60Hz
R(L) S(N)
Indoor unit
earth screw
3 3
1 1
WHI
CN067
(BLK)
RED
3 3
1 1
3 3
1 1
P301
(BLK)
FUSE
(YEL)
CN309
(GRY)
CN304
1 2
1 2
CN040
(BLU)
Outdoor unit
U1 U2
U1 U2
B
1 2
1 2
CN1
A
3 3
2
1 1
L
X Y
1 2
1 2
CN03(RED)
CN02
(BLU)
CN074 1
(WHI) 1
RY002
CN068
(BLU) 1
3
3
3
LM
1
1 2 3 4 5 6
1 2 3 4 5 6
Sub P.C. board
MCC-1520
1 2 3 4 5 6
1 2 3 4 5 6
1 2 3 4 5 6
1 2 3 4 5 6
PMV
1 2 3 4 5 6 CN082
1 2 3 4 5 6 (BLU)
TR
CN01
(WHI)
CN02
(YEL)
1 2 3 4 5 6
T10
CN061
(YEL)
1
EXCT
2
1
2
1
2
3
4
5
CN073
(RED)
CN070
(WHI)
CN081
(BLK)
OPTION
Symbol
FM
RC
TR
TA
TC1,TC2,TCJ
RY001
RY002
RY004
RY005~007
PMV
1 2 3 4 5 6
1 2
CN060
(WHI)
1
2 PNL
3
CN080
(GRN)
RED : RED
WHI : WHITE
YEL : YELLOW
BLU : BLUE
BLK : BLACK
GRY : GRAY
PNK : PINK
ORN :ORANGE
BRN : BROWN
GRN : GREEN
Color
indication
Parts name
Fan motor
Running capacitor
Transformer
Indoor temp sensor
Temp sensor
Louver control relay
Drain control relay
Heater control relay
Fan motor control relay
Pulse motor valve
FILTER
TC1
1 1
2 2
CN100
(BRN)
TC2
TCJ
TA
1 1
2 2
1 1
2 2
1 1
2 2
CN101
(BLK)
CN102
(RED)
CN104
(YEL)
FS
1
3 CN030
1 2 3 (RED)
FAN
DRIVE
CN032
(WHI)
Control P.C. board
for Indoor unit
MCC-1403
CN075
(WHI)
CN033
3 (GRN)
Power supply
circuit
RY001
DP
6 4 3 1 2 5
6 4 3 1 2 5
PMV
indicates the terminal block.
the letter inside indicates the terminal number.
2. A dotted line and broken line indicate
the wiring on site.
3.
Indicates the control p.c. board.
1.
MCC-1401
Network Adapter
(Option)
UL
CN01(WHI)
1 2
1 2
1 2 3 4 5
CN050
(WHI)
RY005
RY006
M
Remote Controller
1 2 3 RC
1
3
RY007
H
RED BLK ORN BLU YEL
FAN
7
5
3
1
CN083 9
(WHI) 9
7
5
3
1
CN041
(BLU)
RY004
T5.0A 250V~
Flow selector
unit earth
screw
Line Filter
AC IN
RC
2
3
4
5
6
BLU
2
3
4
5
6
BLU
104
BLK
11
BLK
FM
1-8. Floor Standing Cabinet Type
Model: MML-AP0071H, AP0091H, AP0121H, AP0151H, AP0181H, AP0241H
WHI
A
B
Outdoor unit
1 2
1 2
CN1
Remote Controller
U1 U2
1 2
1 2
RC
X
Y
MCC-1401
CN03(RED)
CN02
(BLU)
1 1
2 2
CN03
(RED)
CN041
(BLU)
1 2 3
1
3
1 2
1 2
RY007
H
L
UL
CN074 1
(WHI) 1
RY002
RED : RED
WHI : WHITE
YEL : YELLOW
BLU : BLUE
BLK : BLACK
GRY : GRAY
PNK : PINK
ORN :ORANGE
BRN : BROWN
GRN : GREEN
Color
indication
1 2 3 4 5
CN050
(WHI)
RY005
RY006
M
RED BLK ORN BLU YEL
FAN
7
5
3
1 CN068 1
CN083 9
(WHI) 9
(BLU) 1
7
5
3
1
2
4
5
6
3
CN040
(BLU)
CN044
(BRW)
CN066
(WHI)
(BLK)
CN067
T5.0A 250V~
FUSE
(YEL)
CN309
(GRY)
CN304
RY004
RC
2
4
5
6
3
indicates the terminal block.
the letter inside indicates the terminal number.
2. A dotted line and broken line indicate
the wiring on site.
3.
Indicates the control p.c. board.
1.
3 3
2
1 1
EMG
1
2
1
2
3 3
3 3
AC IN
1 1
1 1
3
1
RED
FM
R301
(BLK)
GRN
Network
adapter
(Option)
CN01(WHI)
1 2
1 2
RED BLK ORN BLU YEL
FAN
7
5
3
1
CN083 9
(WHI) 9
7
5
3
1
WHI
RED
For AP0071BH,AP0091BH,AP0121BH
FM
1
3
2
4
5
6
WHI
GRN
U1 U2
TR
Closed-end
connector
Flow selector
unit earth
screw
RED
R(L) S(N)
RED
Power supply
single phase
220-240V 50Hz
220V 60Hz
Indoor unit
earth screw
WHI
1
3
2
4
5
6
3
3
3
3
CN082
(BLU) CN104
(YEL)
CN030
(RED)
1 2 3 4 5 6
Symbol
FM
RC
TR
TA
TC1,TC2,TCJ
RY001
RY002
RY004
RY005~007
PMV
TR
1 2 3 4 5 6 CN01
1 2 3 4 5 6 (WHI)
Sub P.C. board
MCC-1520
1 2 3 4 5 6 CN02
1 2 3 4 5 6 (YEL)
1 2 3 4 5 6
1 2 3 4 5 6
CN061
CN075 (YEL)
(WHI)
CN081
(BLK)
OPTION
Parts name
Fan motor
Running capacitor
Transformer
Indoor temp sensor
Temp sensor
Louver control relay
Drain control relay
Heater control relay
Fan motor control relay
Pulse motor valve
1 2 3 4 5 6
1 2
CN060
(WHI)
FAN
DRIVE
CN032
(WHI)
1
2
3
4
5
FILTER
1
2
CN070
(WHI)
TC2
TCJ
TA
1
EXCT
2
1
2 PNL
3
1 1
2
3 3
1 1
2 2
1 1
2 2
1 1
2 2
CN073
(RED)
CN080
(GRN)
CN100
(BRW)
CN101
(BLK)
CN102
(RED)
1 2 3 4 5 6
1 2 3 4 5 6 PMV
1
3
1 2 3
Control P.C. board
for undoor unit
MCC-1403
3 CN033
3 (GRN)
Power supply
circuit
RY001
1
1
6 4 3 1 2 5
6 4 3 1 2 5
PMV
TC1
1-9. Floor Standing Concealed Type
Model: MML-AP0071BH, AP0091BH, AP0121BH, AP0151BH, AP0181BH, AP0241BH
11
105
RED
WHI
Closed-end
connector
Power supply
single phase
220-240V 50Hz
220V 60Hz
R(L) S(N)
Indoor unit
earth screw
1 1
3
1
P301
(BLK)
FUSE
(YEL)
CN309
1 2
1 2
CN040
(BLU)
(BLK)
CN067
Outdoor unit
U1 U2
U1 U2
1 2
1 2
B
1 2
1 2
CN1
A
3 3
2
1 1
H
MCC-1401
3
3
3
3.
1
1
LM
2 1
2 1
1 2 3 4 5 6 CN02
(YEL)
1 2 3 4 5 6
the letter inside indicates the terminal number.
Indicates the control p.c. board.
the wiring on site.
TR
1 2 3 4 5 6 CN01
1 2 3 4 5 6 (WHI)
Sub P.C. board
MCC-1520
CN061
(YEL)
.
CN081
(BLK)
1 2 3 4 5 6
OPTION
1 2
CN060
(WHI)
FAN
DRIVE
CN032
(WHI)
TC1
RED : RED
WHI : WHITE
YEL : YELLOW
BLU : BLUE
BLK : BLACK
GRY : GRAY
PNK : PINK
ORN :ORANGE
BRN : BROWN
GRN : GREEN
Color
indication
Parts name
Fan motor
Running capacitor
Transformer
Lover motor
Indoor temp sensor
Temp sensor
Louver control relay
Drain control relay
Fan motor control relay
Pulse motor valve
FILTER
1
2
CN070
(WHI)
1
2
3
4
5
1
EXCT
2
CN073
(RED)
TC2
TCJ
TA
1
2 PNL
3
3 3
1 1
1 1
2 2
1 1
2 2
1 1
2 2
CN080
(GRN)
CN100
(BRW)
CN101
(BLK)
CN102
(RED)
CN104
(YEL)
PMV
1 2 3 4 5 6 CN082
1 2 3 4 5 6 (BLU)
6 4 3 1 2 5
6 4 3 1 2 5
PMV
Symbol
FM
RC
TR
LM
TA
TC1,TC2,TCJ
RY001
RY002
RY005~007
PMV
1 2 3 4 5 6
CN075
(WHI)
1 2 3 4 5 6
1 2 3 4 5 6
1
3 CN030
1 2 3 (RED)
FS
Control P.C. board
for Indoor unit
MCC-1403
3 CN033
3 (GRN)
LM
Power supply
circuit
RY001
DP
Indicates the terminal bolock, letter.
X Y
1 2
1 2
CN03(RED)
CN02
(BLU)
CN074 1
(WHI) 1
RY002
Network Adapter
(Option)
CN01(WHI)
1 2
1 2
1 2 3 4 5
CN050
(WHI)
UL
CN068
(BLU) 1
2. A dotted line and broken line indicate
1.
L
RY005
RY006
M
Remote Controller
1 2 3 RC
1
3
RY007
RED BLK ORN BLU YEL
FAN
7
5
3
1
CN083 9
(WHI) 9
7
5
3
1
CN041
(BLU)
RY004
(GRY)
CN304
RC
T5.0A 250V~
Line Filter
TR
EMG
CN066
(WHI)
1
2
CN044
(BRW)
1
2
3 3
3 3
AC IN
1 1
BRW
Flow selector
unit earth
screw
FM
3
4
5
6
7
BLU
3
4
5
6
7
8
BLU
106
BLK
11
BLK
1 1
1-10. Floor Standing Type
Model: MMF-AP0151H, AP0181H, AP0241H, AP0271H, AP0361H, AP0481H, AP0561H
Symbol
SV42
BLU
BLU
1 1
3 3
BLU 5 5
7 7
3 3
T Heater 2
Heater 1
CN315(BLU)
1 1
BRW
3 3
CN316(WHI)
1 1
BRW
CN310(WHI)
4
3
SV51 BLU 2 2
BLU
1 1
CN312(WHI) BLU
3 3
SV2
BLU
1 1
CN324(RED)BLU
3 3
SV3A
BLU
1 1
CN313(YEL) BLU
3 3
SV3B
BLU
1 1
CN314(BLK) BLU
3 3
SV3C
BLU
1 1
SV41
CN311(BLU)
BLU
CM1, CM2
PMV1, PMV2
SV2, SV41, SV42, SV51, SV3A, SV3B, SV3C, SV3D, SV3E
4WV1
COMP1, COMP2
TS1
TD1, TD2
TE1
TO
TK1, TK2, TK3, TK4
TL
HEATER1, HEATER2, ACCU MEATER
FM
PS
PD
63H1, 63H2
MG-SW
OCR
RED : RED
WHI : WHITE
YEL : YELLOW
BLU : BLUE
BLK : BLACK
GRY : GRAY
PNK : PINK
ORN :ORANGE
BRN : BROWN
GRN : GREEN
Color
indication
Central remote
controller
U1 U2
U3 U4
U5 U6
Outdoor
unit
U1 U2
Indoor
unit
WHI
WHI
BLU
BLU
RY508
RY509
CR508
CR509
Parts name
Compressor
Pulse motor valve
2-way valve coil
4-way valve coil
Compressor case thermo.
Pipe temp. sensor (Inlet)
Pipe temp. sensor (Outlet)
Heat exchange temp. sensor
Air temp. sensor
Oil temp. sensor
Liquid temp. sensor
Case heater, 230V, 26W
Fan motor (DC)
Low pressure sensor
High pressure sensor
High pressure switch
Magnet switch
Overcurrent relay
L3
CR517
RY517
RY516
RY507
CR507
CR516
RY506
CR506
RY502
RY503
RY504
L1
CN300
(WHI)
1
1
RY518
CN301
(WHI)
6 5 4 3 2 1
6 5 4 3 2 1
CR504
CR502
CR503
CN01 CN03
(BLU) (WHI)
RED
BRN
BLU
ORN
YEL
WHI
6 5 4 3 2 1
6 5 4 3 2 1
Accumulator
heater
2 CN321
2 (RED)
CR
518
RY510
CR511
SV
3E
4WV1
OCR
MGSW
Comp. IPDU
No.1
MCC-1502
Power supply
for fan
MCC-1439
3
3
Interface
control
P.C. board
(I/F)
MCC-1429
Comp1
BLK
BLK
3 1
3 1
ORN
ORN
Comp. IPDU
No.2
MCC-1502
Fan IPDU
MCC-896 Connecting terminal
U1 U2 U3 U4 U5 U6
Comp2
5
5
7
7
1
1
T6.3A
FUSE
SW10
ON 1 2 3 4
CN305(RED)
SW03
2 CN317 4 3 2 1
2 (BLU)
2 1
Parts layout
Power supply
terminal
L1 L2 L3 N
Noise filter
P.C. board
MCC-1366
SV
3D
SW02
CN307(WHI)
CR521
SW01
D600 D601 D602 D603 D604
SW32
RY521
SW30
SW09
ON 1 2 3 4
SW04 SW05 SW06
SW08
SW07
SW06
SW31
ON 1
ON 1 2 3 4
ON 1 2 3 4
SW14
SW13
SW12
SW11
1 2 3 4 CN323 1
1 2 3 4 (WHI) 1
CR
510
RY511
CN802
Flash
1
2
3
4
5
6
7
8
9
CN800
1
2
3
(Srvice) 4
5
6
ON 1 2 3 4
ON 1 2 3 4
ON 1 2 3 4
ON 1 2 3 4
SW30
ON
3
3
1
1
3
3
63H2
2
1
BLU
BLU
N
L3
L2
L1
GRY
BLK
WHI
RED
Earth screw
CN402
Transformer
WHI
CN401 RED
CN600(WHI)
5 5
4 4
3 3
2 2
1 1
1 1
3 3
Option
board
TL
(WHI)
TK4
(GRN)
TK3
(BLU)
TK2
(BLU)
TK1
(BLK)
TO
(BLK)
TE1
(BLK)
TS1
(GRY)
TD2
(RED)
TD1
(YEL)
RED
V
U
+
Ð
CM2
BLK
WHI
RED
YEL
BLU
CN25 3
(WHI) 3
3
1
5
4
3
2
1
BLK
WHI
BLU
RED
PNK
W
V
U
CN26
(BLU)
1
1
GRY
BLK
WHI
RED
BLK
5
4
3
2
1
1
1
5
4
3
2
1
1 1
3 3
W
V
U
BLK
Ð +
BLK
CN18
CN19
CN02
CN03
1
1
3
3
3
3
BLU
Reactor
CN08
WHI
CN15 CN13
YEL
1
1
6
5
A1 A2
4
3
Mg-SW
1 2
GRY
6
4
OCR
2
RED
BLK
WHI
RED
RED
CN20
WHI
1
1
Ð
PTC Themistor
RED
BLK
WHI
RED
CN07
WHI
CN17
(BLK)
T
CN02 S
CN01 R
CN18
(RED)
5 4 3 2 1
5 4 3 2 1
3
3
RED
RED
RED
WHI
BLK
BLK
GRY
GRY
GRY
IPDU Board (2)
MCC-1502 CN03
CN11
CN10
CN09
CN22
CN23
CN06
(WHI)
5 4 3 2 1
5 4 3 2 1
1
1
CN04 CN20
CN22(WHI) CN23(BLU)
CN17
CN01
CN21
Ð
Reactor
CN21
WHI
BLU
CN15 CN13
CN17
(BLK)
3
3
YEL
BLU
1 1
3 3
5 5
1 1
3 3
+
T
CN02 S
CN01 R
IPDU P.C. Board (1)
MCC-1502 CN03
CN18
(RED)
1 2 3 4 5
1 2 3 4 5
5 4 3 2 1
5 4 3 2 1
CN06
(WHI)
1 2 3 4 5
1 2 3 4 5
CN501
(RED)
CN505(RED)
1 2 3 4 5
CN504
(WHI)
Noise filter
P.C. board
MCC-1366
+
3
3
1
1
CN506(BLK)
CN502
(BLU)
Power supply
P.C. board for FAN
CN503 MCC-1439
CN500
(WHI)
CN11
CN10
CN09
CN22
CN23
CN26
(BLU)
CN25 3
(WHI) 3
5
4
3
2
1
YEL
BLU
1 1
2 2
BLU
3 3
BLK
WHI
CM1
RED
YEL
BLU
YEL
CN01
(WHI)
FAN IPDU
P.C. Board
MCC-896, 897
W
FM
WHI
3.
2.
, and
indicate the terminal blocks and the numerals indicate the terminal numbers.
indicates P.C. board.
(Otherwise water enters into the box resulting in a trouble.)
*Be sure to fix the electric parts cover surely with two screws.
,
accessories sold separately and service cables, respectively.
1. The two-dot chain line indicates wiring at the local site, and the dashed line indicates
Power Supply
3phase
380-415V 50Hz
380 60Hz
1 2 3 4 CN400 3 2 1
1 2 3 4 (WHI) CN325
(YEL)
CN100
(BLK)
CN511
(GRN)
4
3
2
1
4
3
2
1
BLU(BLK)
BLU(BLK)
BLU(BLK)
BLU(BLK)
CN521
(WHI)
1 1
3 3
1 1
3 3
1 1
BLU(BLK)
BLU(BLK)
BLK
2 2
BLK
1 1
CN523
(YEL)
CN516
(RED)
CN515
(GRN)
3 3
BLU(BLK)
BLK
2
BLK
1
BLK
2
BLK
1
BLU(BLK)
3
1 1
3
2
1
CN507
(YEL)
CN514
(BLK)
BLU(BLK)
BLU(BLK)
BLU(BLK)
BLU(BLK)
BLK
2 2
BLK
1 1
1 1
3 3
1 1
3 3
CN505
(GRN)
CN504
(WHI)
CN503
(PNK)
CN308
(BLU)
CN502
(WHI)
63H1
CN306
(WHI)
1
1
T6.3A
FUSE
T6.3A
FUSE
CN512
(BLU)
CN513
(BLU)
CN510
(WHI)
CN509
(BLK)
CN508
(RED)
CN501
(RED)
CN500
(WHI)
Interface Control P.C. Board
MCC-1429
4 3 2 1
4 3 2 1
5 4 3 2 1
5 4 3 2 1
4 3 2 1
4 3 2 1
4 3 2 1
4 3 2 1
Option
Board
Option
Board
4 3 2 1
4 3 2 1
Option
Board
Option
Board
4 3
1
4 3 2 1
RED
BLK
WHI
4 3 2
4 3 2 1
PNK
PNK
PNK
PNK
3 2 1
3 2 1
BLK(PNK)
2 1
2 1
Option
Board
BLK(PNK)
U1 U2 U3 U4 U5 U6
WHI
Pressure
Sensor
PD
ORN
ORN
RED
BRN
BLU
ORN
YEL
WHI
BRN
RED
BLK
Pressure
Sensor
PS
BLU
PMV2
RED
BLK
Except 5HP, 6HP
RED
WHI
BLK
GRY
L1
L2
L3
N
YEL
BLK
WHI
BLU
RED
PNK
BLK
BLK
WHI
BLU
RED
PNK
PMV1
PNK
RED
BLU
WHI
BLK
YEL
YEL
BLK
WHI
BLU
RED
PNK
BLU
PNK
RED
BLU
WHI
BLK
BLU
1 2
1 2
2. Outdoor Unit
Model: MMY-MAP0501HT , MAP0601HT , MAP0801HT , MAP1001HT , MAP1201HT
11
107
108
12
Controls
109
Foreword
110
LONWORKS
Weekly timer
RBC-EXW21E2
Master ON/OFF signal
Batch drive, error output
Energy monitoring
Local supply“
TCS-Net Interface
BMS-IFLSV1E
Energy
meter relay
I/F
Interface
BMS-IFWH3E
BMS-LSV2E
Intelligent server
Air-conditioning Management
System on site
Power peak-cut control signal
Control remote
controller
TCB-SC642TLE2
Alarm Status output
ON/OFF Command
External master
ON/OFF board
TCB-PCDMO2E
Power peak-cut
control board
TCB-PCDM2E
LON Gateway
1 BACnetTM : ANSl/ASHRAE135Ð1995, A Data CommuniCation Protocol for Bulding Automation and ControI Networks.
2 LoNWoRKS¨, Resisterd trademark of Echelon Corporation
Operation status output
Operation control command
Monitoring
Remote control
Schedule operation
Error code indication
Alarm list indication
Monthly report
Energy monitoring
data etc.
Touch
screen
controller
Master ON/OFF signal
Side remote
controller
Master remote
controller
Weekly timer
RBC-EXW21E2
Remote location
ON/OFF control board
TCB IPCB-4E
Super Modular Multi Outdoor Unit
Wired remote controller
RBC-AMT21E
Simple remote controller Wireless remote
RBC-AMT31E
RBC-AS21E2
controller
``1:1model`` connection
interface
TCB-PCNT301TLE2
AI-NET
Central control
devices
AI-NETWORK
Network adapter
TCB-PCNT20E
Super Digital Inverter
Digital Inverter
12 Controls
Foreword
1:1 Outline of application Control
12
111
1. Applications for indoor remote controller
Basic function
Individual control
1-1
Model
Main remote controller Wireless remote controller
Wired remote controller
RBC-AMT21E
RBC-AMT31E
Simple wired remote
controller
RBC-AS21E2
Wireless remote controller
kit
TCB-AX21U(W)-E2
RBC-AX22CE2
TCB-AX21E2
Indoor
unit
Indoor
unit
Possible up to Max.
total length 500m
Remote
controller
(((
Air conditioner is
individually operated
at a distance.
System diagram
Receiver unit
Wireless
CAUTIONS
Remote
controller
Max.8 indoor units
GROUP control
1-2
One remote controller can
control a group of up to a
maximum. 8 indoor units.
Operating on the same
setting
Indoor
unit
Indoor
unit
Indoor
unit
Remote
controller
Possible up to Max.total length 500m
Wired system
Wireless system
Indoor
unit
Indoor
unit
Air conditioner is
controlled by two
remote controllers in
two locations.
12
Master
Side
(
1-3
Wireless
remote
controller 1
Master
Remote
Remote
controller controller
((
(((
Two remote control
Indoor
unit
Wireless
remote
controller2
Side
Possible up to Max.
total length 500m
Wired remote controller
RBC-AMT21E
RBC-AMT31E
Simple wired remote
controller
RBC-AS21E2
Wired remote controller
RBC-AMT21E
RBC-AMT31E
Simple wired remote
controller
RBC-AS21E2
Wireless remote controller
kit
TCB-AX21U(W)-E2
RBC-AX22CE2
TCB-AX21E2
Indoor
unit
((
(
Wired & Wireless
combination control
(Either one of the two
controllers can be set as
side control.)
Remote
controller
Wireless
remote
controller
Weekly timer function
1-4
Control by
weekly timer
Weekly schedule
operation
Indoor
unit
Wired remote controller
RBC-AMT21E
RBC-AMT31E
+
Weekly timer
RBC-EXW21E2
Remote
controller
112
Setting of ON-OFF
3 times par day
Timer operation time is displayed.
Holiday period
Weekly
timer
Foreword
2. Application controls for central remote controller
Basic function
Model
System diagram
Header
unit
U3, U4
Outdoor unit
Line-3
Indoor unit
U5, U6
U1, U2
Zone
4
Header
unit
Indoor remote controller
U3, U4
Outdoor unit
U5, U6
Line-2
Indoor unit
U1, U2
Zone
3
Zone
2
U3, U4
Outdoor unit
Line-1
2-1
Central management
controller for 64
units
Central remote controller
TCB-SC642TLE2
Indoor remote controller
Header
unit
<Indoor remote controller>
Wired remote controller
RBC-AMT21E
RBC-AMT31E
Indoor unit
U1, U2
Zone
1
Indoor remote controller
Power
Central
supply
remote controller
Single phase
220/230/240V
Simple wired remote
controller
RBC-AS21E2
Function of central remote controller
Individual control for up to 64 indoor units
Individual control for max. 64 indoor units
divided in to 4 zones.
(Up to 16 indoor units for each zone.)
Up to 16 outdoor header units are connectable.
4 specific central control settings to restrict individual
operation by remote controller are selectable.
Different settings for 1 to 4 zones.
Usable with other central control devices
(Up to 10 central control devices in one control circuit)
Two selectable control modes
Central controller mode/Remote controller mode
Setting of simultaneous ON/OFF 3 times per day
of the week combined with weekly timer.
U3, U4
Outdoor unit
Central remote
controller
+
2-2
Weekly timer
Weekly operation
schedule
can be set by
connecting a weekly
timer to the central
remote controller
Indoor unit
Indoor remote controller
Single phase
220/230/240V
Power
supply
Central
remote controller
Weekly timer
U1, U2
12
Central remote controller
TCB-SC642TLE2
+
Weekly timer
RBC-EXW21E2
Indoor remote controller
Wired remote controller
RBC-AMT21E
RBC-AMT31E
or
Simple wired remote controller
RBC-AS21E2
113
Basic function
System diagram
U3, U4
Model
Outdoor unit
U1, U2
Power
supply
Indoor unit
Central remote controller
Single phase
220/230/240V
2-3
Either one of the
two controllers
can be set as
side control.
without indoor
remote controller
Even when grouping operation is performed
by connecting multiple indoor units to 1 line,
the indoor remote controller is required.
Central remote controller
TCB-SC642TLE2
Example of grouping operation
U3, U4
Power
supply
Outdoor unit
U1, U2
(Group)
Indoor remote controller
is required
Central remote controller
Single phase
220/230/240V
U3, U4
Available
Indoor remote controller
Wired remote controller
RBC-AMT21E
RBC-AMT31E
Outdoor unit
U1, U2
(Group)
Power
supply
Available
Single phase
220/230/240V
Central remote controller
Power
supply
12
Central remote controller
TCB-SC642TLE2
TCB-CC163TLE2
Central remote controller
U3, U4
2-4
Central management control with
‘‘1 : 1 model’’
Header
unit
Super MMS
U1, U2
Indoor unit
*1
‘‘1:1 model’’
connection
interface
Indoor remote controller
* TOSHIBA Digital Inverter System and Super Digital
Inverter System
114
‘‘1 : 1 model’’ connection
interface
TCB-PCNT30TLE2
RAV-SM560KRT-E,
SM800KRT-E are not
compatible to connect
Indoor remote controller
Wired remote controller
RBC-AMT21E
RBC-AMT31E
Simple wired remote
controller
RBC-AS21E2
3. Application control for network
Basic function
3-1-1
System diagram
Model
LONWORKS
LN interface
TCB-IFLN640TLE
‘‘1 : 1 model’’ connection
interface
TCB-PCNT30TLE2
RAV-SM560KRT-E,
SM800KRT-E are not
compatible to connect
LON Center
LON WORKS
LN Interface
TCB-
TCBTCBIFLN060 • • •
Super MMS
Remote controller
*1
``1:1 model``
connection interface
*1 TOSHIBA Digital Inverter System and Super Digital
Inverter System
Indoor remote controller
Wired remote controller
RBC-AMT21E
RBC-AMT31E
or
Simple wired remote
controller
RBC-AS21E2
The LONWORKS interface should be connected
between a building management computer and a
Super MMS air conditioning system.
3-1-2
BACnet
BACnet center
Local server
BACnet local server
BMS-LSV2E
TCB-
TCB-
TCS-Net
Relay Interface
Super MMS
Remote controller
*1
``1:1 model``
connection interface
*1 TOSHIBA Digital Inverter System and Super Digital
Inverter System
TCS-Net Relay Interface
BMS-IFLSV1E
‘‘1 : 1 model’’ connection
interface
TCB-PCNT30TLE2
RAV-SM560KRT-E,
SM800KRT-E are not
compatible to connect
12
Indoor remote controller
Wired remote controller
RBC-AMT21E
RBC-AMT31E
Simple wired remote
controller
RBC-AS21E2
The local server should be connected to the BACnet
network, and the Super MMS air conditioning
system through the interface.
115
Touch screen controller system
System Diagram
Intelligent Server Software
Ethernet
connection
RS-485
Control wiring
Outdoor units
TCS-Net Relay Interface
Intelligent Server
Touch Screen
Controller
Indoor units
Control wiring
Remote controller
Control Maximum 512 FCU
Control wiring
Maximum 4 Intelligent server
Maximum 8 Relay Interface
Maximum 4 Energy Monitoring
Relay Interface
I/F
Energy Meter Relay Interface
Fire alarm
Door Key Entry ON/OFF
Error code output
3-2-1
Maximum 8 Power Meter
Maximum 4 Digital
I/O Relay Interface
Digital I/O Relay Interface
Function
Devices
Model Name
Touch Screen controller
(English version)
12
I/F
Local supply
1kWh/pulse or 10kWh/pulse
50-1000 ms
Pulse Signal
Intelligent Server
Intelligent Server Software
TCS-Net Relay Interface
Energy Monitoring Relay Interface
Digital I/O Relay Interface
Model Name
BMS-TP0640ACE
BMS-TP5120ACE
BMS-TP0640PWE
BMS-TP5120PWE
BMS-LSV2E
BMS-STCC01E
BMS-IFLSV1E
BMS-IFWH3E
BMS-IFDD01E
Specification
Max 64 FCU , without electrical bill calculation
Max 512 FCU , without electrical bill calculation
Max 64 FCU , with electrical bill calculation
Max 512 FCU , with electrical bill calculation
Server in between Touch Screen controller & RS-485
Installed on Intelligent Server
I/F in between Intelligent server & Control wiring
I/F for Power Meter
I/F for I/O signal
(1) Monitoring air-conditioners
Operation status can be viewed according to a unit.
Unit All building, All tenants, Each tenant, Each area, Each air-conditioning system
Monitoring contents Operation and alarm status, Setting status for each air-conditioning system
(2) Operating of air-conditioners
Header / individual control can be performed according to a unit.
Operating contents ON/OFF, Operation setting (operation mode, air volume,
louver position, setting temp., restricted setting from remote location)
(3) Schedule operation
Air-conditioners are operated according to the set-up schedule / operation pattern.
Schedule opretaion can be performed according to a unit.
Operation pattern
Weekly pattern, special day pattern (4 pattern), Non-operation days pattern
(4) Alarm list display
The present alarm contents are list-displayed.
Display contents Alarm contents, Unit number, Generated time
The alarm history records are displayed.
Display contents Alarm contents, Unit number, Generated time
Monthly report data is wrtten to ‘‘Compact Flash’’. Monthly reports can be created according to
a unit using the monthly report software.
Monthly report contents The number of ON/OFF, Operating time, Results of energy monitoring
(5) Alarm record display
(6) Monthly report data extraction
(7) Energy monitoring data extraction Power consumption data is written to ‘‘Compact Flash’’. Energy monitoring can be performed
according to a unit using the energy monitoring software.
Energy monitoring data Power consumption according to the power meter
116
3-2-2
Basic function
System diagram
Windows based
central controller
(Now planning)
Personal computer on site
Model
server
Relay Interface
*1
Super MMS
Remote controller
‘‘1:1 model’’
connection interface
Energy monitoring relay interface
Digital I/O relay interface
*1 TOSHIBA Digital Inverter System and Super Digital
Inverter System
12
117
Application control of optional devices connectable to indoor units
Remote location ON/OFF control box
Model
Name
Appearance
Features
Start and stop of the air conditioner is possible
by a external signal and indication of
operation/alarm externally.
TCB-IFCB-4E
Application
Function
Monitoring
ON/OFF status (for indoor unit)
Alarm status (system & indoor unit stop)
ON/OFF command
Air conditioner can be turned ON/OFF
by external signals.
The external ON/OFF signals will initiate
the signals shown below.
Operation
Interface
Display
Remote
Controller
ON /OFF
COM
Non-voltage
ON /OFF continious signal
Network adapter
Model
Name
Appearance
Features
Indoor units of Super MMS system are
controlled by AI-NETWORK central
remote controller.
Connectable indoor units per group.
12
TCB-PCNT20E
Connection of cables
Install optional P.C. board in Electrical parts box
of indoor unit.
Application
Power
Supply
AI Network
Wiring diagram of indoor P.C. board
Central Remote
Controller
TCB-SC641E
Network Adapter
Indoor unit
118
‘‘1:1 model’’ connection interface
Model
Name
Appearance
Features
Link adapter for ‘‘1:1 model’’ into
super modular muti network
1:1 model : Super digital inverter
Digital inverter
TCB-PCNT30TLE2
Connection of cables
Install optional P.C. board in Electrical parts box
of indoor unit.
ON-OFF
control
devices
Application
TCB-CC163TLE2
Central Remote
Controller
TCB-SC642TLE2
Super MMS control wiring
Wiring diagram of indoor P.C. board
1:1 model
connection
interface
Indoor units
Digital Inverter
Super Digital Inverter
adoptor
Outdoor unit
12
119
Application controls by optional P.C. board of outdoor unit
Model
Name
Appearance
Function
1 Power peak-cut Control
Feature
The upper limit capacity of the outdoor unit is
restricted based on the power peak cut request
signal from outside.
Size : 71 x 85
Function
Two types of control can be selected by setting
SW07 on the interface P.C. board on the
header outdoor unit.
TCB-PCDM2E
Local Supply
ON
Application
TCB-PCDM2E
OFF
SW2
COM
*Install this optional
P.C. board in the
inverter assembly
of the header
outdoor unit.
12
SW1
COM
Standard funciton
SW07-2 OFF
Input
SW01
SW02
ON
OFF
OFF
ON
SW07-1
OFF
ON
0% (stop)
Up to 60%
100%(Nomal) 100%(Normal)
Expansion function
SW07-2 ON
Input
SW01
SW02
OFF
OFF
ON
OFF
OFF
ON
ON
ON
SW07-1
ON
OFF
100%(Nomal) 100%(Normal)
Up to 80%
Up to 85%
Up to 60%
Up to 75%
0%(stop)
Up to 60%
Ensure terminal contacts are securely fixed.
Do not turn on both SW1 and SW2 terminals simultaneously.
120
Model
Name
Appearance
Function
2 Snowfall fan control
Feature
Outdoor fan is operated by a snowfall signal from outside.
Function
TCB-PCMO2E
Local Supply
COM
TCB-PCM02E
SMC
Size : 55.5 x 60
Cooling
Application
SMC : Cooling mode select input (switch)
Terminal Input signal Operation
ON
Snowfall fan control
(Operates outdoor fan.)
SMC OFF
ON
Usual operation
OFF
This control is activated when a input signal increases or decreases.
(The increasing or decreasing signal needs to be held for a minimum
of 100m/sec in order to activate the control).
3 External master ON/OFF control
Feature
The outdoor unit starts or stops the system.
Function
TCB-PCMO2E
Local Supply
COM
SMC
Cooling
Heating
*Install this optional
P.C. board in the
inverter assembly
of the header
outdoor unit.
SMH
12
SMC : Input signal for start
SMH : Input signal for stop
Terminal Input signal Operation
Starts all indoor units.
ON
SMC
SMH
ON
OFF
Stops all indoor units.
OFF
Ensure terminal contacts are securely fixed.
This control is activated when a input signal increases or decreases.
(The increasing or decreasing signal needs to be held for a minimum
of 100m/sec in order to activate the control).
121
Model
Name
Appearance
Function
4 Night operation (Sound reduction) control
Feature
Sound level can be reduced by restricting the compressor
and fan speeds.
Function
TCB-PCM02E
TCB-PCMO2E
Size : 55.5 x 60
Local Supply
COM
SMC
Cooling
Application
SMC : Cooling mode designated input switch
Terminal Input signal Operation
ON Night operation control
OFF
ON
SMC
Usual operation
OFF
This control is activated when a input signal increases or decreases.
(The increasing or decreasing signal needs to held for a minimum of
100m/sec in order to activate the control).
5 Operation mode selection control
Feature
This control can restrict the selectable operation mode.
Function
12
*Install this optional
P.C. board in the
inverter assembly
of the header
outdoor unit.
TCB-PCMO1E
Local Supply
COM
SMC
Cooling
Heating
SMH
SMC : Cooling mode designated input switch
SMH : Heating mode designated input switch
SMC
ON
SMH
OFF
OFF
ON
Selected operation mode
Only cooling mode
permitted
Only heating mode
permitted
Ensure terminal contacts are securely fixed.
122
Remote controller
Wired remote controller
RBC-AMT31E
120
120
84
18
62
16
RBC-AMT21E
2.7
4
120
12
16
120
123
Simple wired remote controller
60
70
12
124
120
80
RBC-AS21E / RBC-AS21E2
13
16
Wireless remote controller
TCB-AX21U (W)-E / TCB-AX21U (W)-E2
186
19.5
32
177
186
58
61
Wireless remote controller kit
RBC-AX22CE / RBC-AX22CE2
130
19.5
12
177
65
58
61
125
Wireless remote controller kit
TCB-AX21E / TCB-AX21E2
58
19.5
83.5
177
83.5
4.4 x 9.4 long hole
13
70
4.4 x 5.4 long hole
61
Weekly timer
RBC-EXW21E / RBC-EXW21E2
2.7
4
120
12
16
120
126
Remote sensor
120
80
TCB-TC21LE / TCB-TC21LE2
13
60
70
16
Central remote controller
TCB-SC642TLE / TCB-SC642TLE2
160
148
21
69
Z
115
(6)
121
6
148
(6)
160
6
13
15
116
47
12
121
47
80
128
36
13
128
80
Z view (back side)
127-1
127
ON-OFF controller
TCB-CC163TLE2
116
Unit: mm
160
(6)
148
14
69
115
121
148
(6)
160
6
6
Z
122
4-Ø5 diameter holes
(for mounting)
128
Hole for electrical wiring
80
47
80
128
36
13
12
4-Ø5.5 diameter holes (for mounting)
Z-view (back side)
128
127-2
TCS-Net relay interface
BMS-IFLSV1E
200
6- 5.5 mounting holes
78
78
22
22
78
78
22
66
63.6
156
170
146.9
22
Touch screen controller
BMS-TP0640ACE
BMS-TP5120ACE
BMS-TP0640PWE
BMS-TP5120PWE
256
91.75
70
99.3
75
242
95.75
75
302
55.5
19 30
82.5
48
16
5
12
316
249
54
49
127-3
129
Intelligent server
39
CAUTION
Do not remove.
198
BMS-LSV2E
370
WARNING
Do not decompose.
Energy monitoring relay interface / Digital I/O relay interface
BMS-IFWH3E
BMS-IFDDO1
63.6
200
(2.4)
5.5 mounting hole
63.6
130
128
78
78
22
12.55
22
170
144.9
146.9
7
156
7
6
12.55
(2.4)
12
Dimension
TCB-PCDM2E
71
Terminal
Screw M3 x 6
4-4ø hole
75
85
61
Terminal
Screw M4 x 8
TCB-PCMO2E
55.5
4-4ø hole
45.5
50
60
Terminal
Screw M3 x 6
12
TCB-PCIN2E
4-
4 hole
63
73
79
69
Terminal (Screw M3 )
129
131
12
130
132
13
Fan characteristics
131
Foreword
13
132
13 Fan characteristics
Foreword
A
MMD-AP0121BH
Standard air volume:480m3/h
gh
Hi
ati
cp
120
res
su
lim
it
-st
re
2
H
at
pl
Ap
Sta
Lo
40
w
sta
Sta
nd
tic
nd
ard
pre
ard
tat
H
ss
ic
ss
ure
1H
tap
tap
ure
Lt
pre
H
tap
Ap
100
80
60
ic
pl
a
ti
on
lim
Lo
40
w
Sta
an
sta
nd
ap
gh
da
rd
tic
sta
H
pr
es
ard
Lt
tic
ta
pr
es
long life filter
0
200
0
300
600
480
H
su
re
2
su
re
H
ta
H
ta
p
tap
p
ap
Air volume(m /h)
MMD-AP0181BH
Standard air volume:650m3/h
140
Standard air volume:780m3/h
140
Hig
ic
Hig
h st
Sta
Low
sta
tic
atic
nda
pre
40
Sta
nda
pre
ssu
re 1
rd H
tap
pre
H ta
ssu
p
re 2
H
tap
A
100
80
60
Air volume limit (Min)
pl
tatic
External static pressure (Pa)
Air volume limit (Min)
Ap
at
ion
lim
it
h-s
120
Air volume limit (Max)
Hig
120
100
700
570
3
MMD-AP0151BH
External static pressure (Pa)
re
1
pr
es
p
500
Air volume(m /h)
l
pp
ti
ica
o
i
nl
ssu
re H
Hig
Sta
hs
nda
rd
sta
tat
Sta
rd
Lt
ap
nd
20
ic p
Ht
tic
40
tap
h-s
t
mi
Low
20
ard
res
s
tat
ic p
ure
1H
ap
pre
Lt
ssu
re H
res
s
ure
tap
2H
tap
13
tap
ap
long life filter
long life filter
0
400
su
tic
long life filter
400
3
60
ta
20
20
80
-s
it
Hi
St
gh
Air volume limit (Max)
60
hs
tap
Air volume limit (Max)
n
io
80
Hig
ic
100
Air volume limit (Min)
External static pressure (Pa)
120
Air volume limit (Min)
Hi
Standard air volume:570m3/h
140
External static pressure (Pa)
140
Air volume limit (Max)
MMD-AP0071BH, AP0091BH
600
650
Air volume(m3/h)
800
0
500
700
780
900
Air volume(m3/h)
133
MMD-AP0241BH, AP0271BH
MMD-AP0301BH
Standard air volume:1140m3/h
on
High
Air volume limit (Min)
100
80
60
static
Stand
Low
static
press
ure 1
H tap
ard H
tap
2H ta
p
Ap
plic
ure H
tap
100
High
80
60
Stan
ard L
tap
1000
0
900
1200
1140
pres
sure
re 2H
tap
1H ta
p
H ta
p
ure H
tap
dard
L tap
1100
MMD-AP0481BH, AP0561BH
Standard air volume:1980m3/h
High
Air volume limit (Min)
100
static
Stan
Low
dard
static
Stan
dard
pres
ic pre
ssu
sure
sure
re 2H
tap
1H t
ap
H ta
p
pres
40
-stat
120
H ta
p
100
80
60
c
pli
o
ati
im
nl
Hig
it
Hig
h st
Sta
Low
stat
h-s
atic
nda
Sta
L tap
pre
ic p
ress
u
nda
tati
cp
ssu
res
s
re 1
ure
H ta
2H
p
rd H
tap
40
20
re H
tap
rd L
tap
20
long life filter
0
1200
Ap
Air volume limit (Min)
ca
pli
tio
i
nl
High
t
mi
140
External static pressure (Pa)
120
Air volume limit (Max)
140
long life filter
1620
Air volume(m3/h)
2000
0
1400
1800
1980
Air volume(m3/h)
2200
tap
Air volume limit (Max)
Standard air volume:1620m /h
3
Ap
1260 1300
Air volume(m3/h)
MMD-AP0361BH
External static pressure (Pa)
ic pre
ssu
long life filter
Air volume(m3/h)
134
static
dard
press
-stat
20
0
800
60
static
Stan
long life filter
13
nl
t
imi
40
20
80
atio
Low
press
40
Stand
High
120
Air volume limit (Min)
ati
ic pre
ssure
External static pressure (Pa)
A
lic
pp
lim
it
-stat
Air volume limit (Max)
High
120
External static pressure (Pa)
Standard air volume:1260m3/h
140
Air volume limit (Max)
140
Foreword
Concealed Duct High Static Pressure type
MMD-AP0241H, AP0271H
Standard air volume: 900 m3/h
1.5
High static pressure tap
Medium static pressure tap
1.0
Low static pressure tap
0.5
Fan motor current (A)
Fan motor current (A)
MMD-AP0181H
2.0
Standard air volume: 1320 m3/h
High static pressure tap
Medium static pressure tap
1.5
Low static pressure tap
1.0
300
250
w
m
st
at
ic
es
pr
es
st
at
m
st
at
ic
pr
es
100
p
900
su
re
re
ta
ta
p
p
1000
p
800
su
ta
50
700
es
re
0
iu
pr
su
ta
ed
ic
es
re
50
p
150
M
at
pr
su
ta
200
ic
es
re
ap
st
at
pr
su
re
t
gh
st
ic
su
Hi
Air volume upper limit
iu
pr
Air volume lower limit
Lo
ed
tic
50Hz
60Hz
w
100
M
sta
250
Outside static pressure (Pa)
150
Air volume lower limit
200
50Hz
60Hz
Air volume upper limit
gh
Lo
Outside static pressure (Pa)
Hi
0
1000
1100
1100
1320
1300
1400
1200
1500
1600
Air volume (m3/h)
Air volume (m3/h)
MMD-AP0361H
MMD-AP0481H
Standard air volume: 1600 m3/h
Standard air volume: 2100 m3/h
3.0
Fan motor current (A)
Fan motor current (A)
2.5
High static pressure tap
2.0
Medium static pressure tap
1.5
Low static pressure tap
High static pressure tap
2.5
2.0
Medium static pressure tap
1.5
1.0
Lo
Low static pressure tap
100
diu
m
Lo
50Hz
60Hz
tati
sta
w
cp
tic
sta
res
pre
tic
sur
e ta
ssu
pre
ss
re
t
ure
50
0
1400
1500
1600
ap
tap
1700
Air volume (m3/h)
p
250
200
150
Hi
M
ed
iu
Lo
100
gh
sta
m
w
st
st
at
50Hz
60Hz
tic
at
ic
ic
pr
pr
es
pr
es
es
su
su
su
re
50
1800
0
re
t
re
ta
ap
ta
Air volume upper limit
150
Me
hs
Air volume lower limit
200
Air volume lower limit
Outside static pressure (Pa)
Hig
Outside static pressure (Pa)
250
Air volume upper limit
0.5
13
p
p
2100
1500
2000
2500
Air volume (m3/h)
135
MMD-AP0721H
Standard air volume : 3600m3/h
8
High static pressure tap (60Hz)
Current of fan motor (A)
7.5
7
Medium static pressure tap (60Hz)
Low static pressure tap (60Hz)
6.5
6
High static pressure tap (50Hz)
Medium static pressure tap (50Hz)
5.5
5
4.5
Low static pressure tap
External static pressure (Pa)
4
300
High static pressure tap (50Hz)
250
200
150
High static pressure tap (60Hz)
100
50
Medium static pressure tap (50Hz)
Medium static pressure tap (60Hz)
Low static pressure tap (50Hz)
5
2880 3000
3200
3400
3600
3800
4000
4200 4320
Air volume (m3/h)
Lower limit of air volume
Low static pressure tap (60Hz)
Upper limit of air volume
MMD-AP0961H
Standard air volume : 4200m3/h
8.5
Current of fan motor (A)
8
High static pressure tap (60Hz)
Medium static pressure tap (60Hz)
Low static pressure tap (60Hz)
7.5
7
High static pressure tap (50Hz)
6.5
Medium static pressure tap (50Hz)
6
5.5
5
Low static pressure tap
4.5
13
External static pressure (Pa)
4
350
High static pressure tap (60Hz)
300
High static pressure tap (50Hz)
250
200
150
100
50
5
3360
Lower limit of air volume
Medium static pressure tap (50Hz)
Low static pressure tap (50Hz)
Low static pressure tap (60Hz)
3600
4000
4400
Air volume (m3/h)
4800
5040 Medium static pressure tap (60Hz)
Upper limit of air volume
REQUIREMENT
Add a air volume damper to the supplied air duct, and adjust the air volume from 80% to 120% of
the standard air volume.
136
AIR SPEED CHARACTERISTICS
Air Speed Distribution
B
4-way air discharge cassette type
MMU-AP0091H, AP0121H
MMU-AP0151H
2.8m
2.7m
0.7m/s
2
0.3m/s
2
0.5m/s
0.5m/s
0.7m/s
1
1
0.3m/s
0
0
1
2
3
4
1
2
3
4
5m
5m
MMU-AP0181H
MMU-AP0241H,AP0271H
3.6m
3
2.8m
0.7m/s
2
0.7m/s
1
1
2
3
4
0.3m/s
1
0.3m/s
0
0.5m/s
2
0.5m/s
0
5m
1
2
3
4
5m
MMU-AP0301H
MMU-A0361H
3.6m
3
3.6m
2
0.7m/s
3
0.7m/s
0.5m/s
2
0.5m/s
0.3m/s
1
1
0.3m/s
0
0
1
2
3
4
1
2
3
4
5m
5m
MMU-AP0561H
MMU-A0481H
3.6m
3
0.7m/s
3.6m
3
0.3m/s
0.5m/s
2
1
0.3m/s
1
0
0.5m/s
2
0.7m/s
1
2
3
13
4
5m
0
1
2
3
4
5m
137
Air Speed Distribution
2-way air discharge cassette type
MMUAP0071WH, AP0091WH, AP0121WH
MMUAP0151WH, AP0181WH
2.7m
Ceiling height (m)
Ceiling height (m)
2.7m
2
1.0
0.5
(m) 1
0.3
0.3
0
1
2
2
1.0
(m) 1
0.5
0.3
0.3
0
3m
Horizontal distance (m)
1
2
3m
Horizontal distance (m)
MMU-AP0241WH, AP0271WH
Ceiling height (m)
2.7m
2
1.0
(m) 1
0.5
0.3
0.3
0
1
2
3m
Horizontal distance (m)
MMU-AP0481WH
MMU-AP0301WH
13
2.7
Ceiling height (m)
Ceiling height (m)
2.7
2
1.0
1
0.5
0.3
0
1.0
1
0.3
1
2
3
Horizontal distance (m)
138
2
0.5
0.3
0.3
4
0
1
2
3
Horizontal distance (m)
4
Air Speed Distribution
1-way air discharge cassette type
MMU-AP0071YH, AP0091YH, AP0121YH
H (High wind,
blowing downward)
2.7m
L (Low wind,
blowing downward)
5.0
4.0
2.7m
2
2
H (High wind,
blowing horizontally)
2.7m 4.5
1.7
2
2.5
L (Low wind,
blowing horizontally)
2.7m 3.0
0.3
2
1.5
0.4
1.5
1.1
0.3
2.3
1
1
1
0.4
0
0.6
1
1
0.5
0.9
0.4
2
3m
0.2
0
0.2
0.3
1
2
3m
0
MMU-AP0151SH,AP0181SH
1
2
3m
0
1
2
3m
MMU-AP0241SH
2.7m
2.7m
2
2
1.0
1.0
0.3
0
0.5
1
1
0.5
1
0.3
0.3
2
0.3
0
3m
1
2
3m
Under ceiling type
MMC-AP0181H,AP0481H
1m
MMC-AP0361H
1m
2m
2m
1.0
3m
0.3
1m
0.3
0.5
3m
0.5
2m
1.0
0.3
0.3
0.5
3m
4m
1m
2m
3m
13
4m
MMC-AP015H,AP0241H,AP0271H
1m
2m
1.0
3m
0.3
0.3
1m
2m
0.5
3m
4m
139
Discharge Air Speed and Air Throw
High wall type
MMK-AP0071H, AP0091H, AP0121H
High wind: 5.0m/s
Med. wind: 4.4m/
s
4
3
2
1
0
1
2
3
4
5
6
High wind: 5.0m/s
Med. wind: 4.4m/
s
Horizontal discharge Initial
speed
5
Air speed (m/s)
Horizontal discharge Initial
speed
5
Air speed (m/s)
MMK-AP0151H, AP0181H
7
4
3
2
1
0
1
2
Horizontal throw (m)
3
4
5
6
7
Horizontal throw (m)
MMK-AP0241H
High wind: 5.0m/s
Med. wind: 4.4m/
s
Air speed (m/s)
Horizontal discharge Initial
speed
5
4
3
2
1
0
1
2
3
4
5
6
7
Horizontal throw (m)
Floor standing cabinet type
High wind
2
Med. wind
Low wind
1
0
1
2
3
4
5
6
7
Distance from discharge grille (m)
3
High wind
Med. wind
Low wind
2
1
0
1
2
3
4
5
6
7
Distance from discharge grille (m)
MML-AP0181H, AP0241H
Air speed (m/s)
3
MML-AP0121H, AP0151H
Air speed (m/s)
Air speed (m/s)
13
MML-AP0071H, AP0091H
4
High wind
3
Med. wind
2
Low wind
1
0
1
2
3
4
5
6
7
Distance from discharge grille (m)
140
8
Air Speed Distribution
Floor standing type
(m)
MMF-AP0151H, AP0181H
(m)
2.7
MMF-AP0241H, AP0271H
2.7
0.5m/s
2.0
2.0
0.5m/s
1.5m/s
1.0m/s
0.7m/s
1.5m/s
1.0
1.0m/s
1.0
1
2
3
4
5
6
7
8
(m)
MMF-AP0361H
(m)
1
(m)
2.7
2
3
4
5
6
7
8
(m)
MMF-AP0481H,AP0561H
2.7
2.0
1.5m/s
2.0m/s
0.5m/s
1.0m/s
2.0
1.5m/s
1.0
1.5m/s
1.5m/s
1.0m/s
1.0
1
2
3
4
5
6
7
8
(m)
1
2
3
4
5
6
7
8
(m)
13
141
142
14
Sound characteristics (NC CURVE)
143
Foreword
144
14 Sound characteristics
Foreword
(NC CURVE)
Sound level data (NC CURVE)
Sound level values shown are based on a measurement in a non resound room.
Microphone
Octave band sound pressure level (dB)
MMU-AP0091H, AP0121H
Fan Tap
H
M
L
Sound pressure
level(dB(A))
30
29
27
Audibility limits of
continous white sound
Octave band frequency(Hz)
MMU-AP0181H
Fan Tap
H
M
L
Fan Tap
H
M
L
Sound pressure
level(dB(A))
31
29
27
Sound pressure
level(dB(A))
32
29
28
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
MMU-AP0151H
Audibility limits of
continous white sound
Octave band frequency(Hz)
Audibility limits of
continous white sound
Octave band frequency(Hz)
Octave band sound pressure level (dB)
MMU-AP0241H, AP0271H
Fan Tap
H
M
L
Sound pressure
level(dB(A))
34
31
28
14
Audibility limits of
continous white sound
Octave band frequency(Hz)
145
Sound level data (NC CURVE)
MMU-AP0301H
MMU-AP0361H
H
M
L
37
33
30
Octave band sound pressure level (dB)
Fan Tap
Sound pressure
level(dB(A))
Octave band sound pressure level (dB)
Sound level values shown are based on a measurement in a non resound room.
Audibility limits of
continous white sound
Fan Tap
H
M
L
Sound pressure
level(dB(A))
40
36
33
Audibility limits of
continous white sound
Octave band frequency(Hz)
MMU-AP0561H
Fan Tap
H
M
L
Fan Tap
H
M
L
Sound pressure
level(dB(A))
44
38
34
Sound pressure
level(dB(A))
45
48
34
Audibility limits of
continous white sound
Octave band frequency(Hz)
14
146
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
MMU-AP0481H
Octave band frequency(Hz)
Audibility limits of
continous white sound
Octave band frequency(Hz)
Foreword
Sound level data (NC CURVE)
Sound level values shown are based on a measurement in a non resound room.
MMU-AP0071WH, AP0091WH, AP0121WH
Fan Tap
H
M
L
Sound pressure
level(dB(A))
34
32
30
Microphone
Octave band sound pressure level (dB)
standard sound pressure 0.0002 µbar
Audibility limits
of continous
white level
Octave band frequency (Hz)
MMU-AP0241WH, AP0271WH
MMU-AP0151WH, AP0181WH
Fan Tap
H
M
L
Sound pressure
level(dB(A))
35
33
30
Audibility limits
of continous
white level
Octave band frequency (Hz)
H
M
L
38
35
33
standard sound pressure 0.0002 µbar
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
standard sound pressure 0.0002 µbar
Fan Tap
Sound pressure
level(dB(A))
14
Audibility limits
of continous
white level
Octave band frequency (Hz)
147
Sound level data (NC CURVE)
MMU-AP0301WH
MMU-AP0481WH
H
Fan Tap
Sound pressure
level(dB(A))
40
M
L
37
34
H
M
L
45
42
39
90
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
H
M
20
Audibility limits
of continous white level
NC-20
L
10
63
125
250
500
1000
2000
4000
8000
Octave band sound pressure level (dB)
90
Octave band sound pressure level (dB)
Fan Tap
Sound pressure
level(dB(A))
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
H
M
30
NC-30
L
20
NC-20
Audibility limits
of continous white level
10
63
Octave band center frequency (Hz)
125
250
500
1000
2000
4000
MMU-AP0151SH, AP0181SH
Fan Tap
H
M
L
Sound pressure
level(dB(A))
42
39
36
Octave band sound pressure level (dB)
Microphone
NC-70
NC-60
NC-50
NC-40
NC-30
Audibility limits
of continous white level
Octave band frequency (Hz)
MMU-AP0241SH
148
H
M
L
43
41
37
Octave band sound pressure level (dB)
14
Fan Tap
Sound pressure
level(dB(A))
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
Audibility limits
of continous white level
Octave band frequency (Hz)
8000
Octave band center frequency (Hz)
NC-20
Sound level data (NC CURVE)
MMD-AP0071BH, AP0091BH
Fan Tap
Sound pressure level
(dB(A))
H
M
L
30
28
26
Octave band sound pressure level(dB)
90
Microphone
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
H
M
30
NC-30
L
20
Audibility limits of
white level
NC-20
10
63
125
250
500
1000
2000
4000
8000
Octave band center frequency (Hz)
MMD-AP0121BH
MMD-AP0151BH
H
M
L
31
29
27
Fan Tap
Sound pressure level
(dB(A))
90
90
80
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
H
20
Audibility limits of
white level
NC-20
M
L
10
Octave band sound pressure level(dB)
Octave band sound pressure level(dB)
Fan Tap
Sound pressure level
(dB(A))
H
M
L
31
29
27
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
H
Audibility limits of
white level
20
NC-20
M
L
10
63
125
250
500
1000
2000
4000
8000
63
125
250
500
1000
2000
4000
8000
Octave band center frequency (Hz)
Octave band center frequency (Hz)
MMD-AP0181BH
Fan Tap
Overall level
dB(A)
H
M
L
32
30
28
Octave band sound pressure level(dB)
90
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
H
M
20
L
Audibility limits of
white level
14
NC-20
10
63
125
250
500
1000
2000
4000
8000
Octave band center frequency (Hz)
149
Sound level data (NC CURVE)
MMD-AP0241BH, AP0271BH
H
M
L
33
31
29
Fan Tap
Sound pressure level
(dB(A))
90
90
80
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
white level
Octave band sound pressure level(dB)
Octave band sound pressure level(dB)
Fan Tap
Sound pressure level
(dB(A))
MMD-AP0301BH
10
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
Audibility limits of
white level
125
250
500
1000
2000
4000
8000
63
125
MMD-AP0361BH
H
M
L
36
34
32
500
Fan Tap
Sound pressure level
(dB(A))
90
80
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
NC-20
Audibility limits of
white level
10
Octave band sound pressure level(dB)
90
20
250
1000
2000
4000
8000
MMD-AP0481BH, AP0561BH
Fan Tap
Sound pressure level
(dB(A))
Octave band sound pressure level(dB)
NC-20
Octave band center frequency (Hz)
Octave band center frequency (Hz)
H
M
L
38
36
32
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
white level
NC-20
10
63
125
250
500
1000
2000
4000
8000
Octave band center frequency (Hz)
150
L
29
10
63
14
M
32
70
20
NC-20
H
34
63
125
250
500
1000
2000
4000
8000
Octave band center frequency (Hz)
Sound level data (NC CURVE)
Sound level values shown are based on a measurement in a non resound room.
Microphone
MMD-AP0181H
(dB)
196.0 (Pa)
Overall level A
33
37
40
C
46
51
53
(dB)
(standard sound pressure 0.0002 µbar)
196.0(external static pressure(Pa))
Audibility limits
of continous
white level
Octave band center frequency (Hz)
MMD-AP0241H, AP0271H
Outside still pressure 68.6 (Pa)
Octave band sound pressure level (dB)
(dB)
Outside still pressure 68.6 (Pa)
Octave band sound pressure level (dB)
137.2 (Pa)
196.0 (Pa)
Overall level A
36
40
44
C
50
53
57
(dB)
137.2 (Pa)
196.0 (Pa)
Overall level A
33
37
40
C
47
49
53
(dB)
(standard sound pressure 0.0002 µbar)
196.0(external static pressure(Pa))
Audibility limits
of continous
white level
Octave band center frequency (Hz)
(dB)
137.2 (Pa)
(standard sound pressure 0.0002 µbar)
196.0(external static pressure(Pa))
Audibility limits
of continous
white level
Octave band center frequency (Hz)
(dB)
Outside still pressure 68.6 (Pa)
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
Outside still pressure 68.6 (Pa)
Overall level A
(dB)
C
137.2 (Pa)
196.0 (Pa)
36
40
44
50.5
53
57
(standard sound pressure 0.0002 µbar)
196.0(external static pressure(Pa))
14
Audibility limits
of continous
white level
Octave band center frequency (Hz)
151
MMD-AP0361H
(dB)
(dB)
Overall level A
(dB)
C
36
49.5
137.2 (Pa)
196.0 (Pa)
40
44
54
Outside still pressure 68.6 (Pa)
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
Outside still pressure 68.6 (Pa)
59
(standard sound pressure 0.0002 µbar)
196.0(external static pressure(Pa))
Audibility limits
of continous
white level
Octave band center frequency (Hz)
137.2 (Pa)
196.0 (Pa)
Overall level A
36
40
44
C
49
53.5
57
(dB)
(standard sound pressure 0.0002 µbar)
196.0(external static pressure(Pa))
Audibility limits
of continous
white level
Octave band center frequency (Hz)
(dB)
(dB)
14
152
137.2 (Pa)
196.0 (Pa)
Overall level A
36
40
44
C
47
51
54
(dB)
(standard sound pressure 0.0002 µbar)
196.0(external static pressure(Pa))
Audibility limits
of continous
white level
Octave band center frequency (Hz)
Outside still pressure 68.6 (Pa)
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
Outside still pressure 68.6 (Pa)
137.2 (Pa)
196.0 (Pa)
Overall level A
36
40
44
C
47
51
54
(dB)
(standard sound pressure 0.0002 µbar)
196.0(external static pressure(Pa))
Audibility limits
of continous
white level
Octave band center frequency (Hz)
Sound level data (NC CURVE)
Sound level values shown are based on a measurement in a non resound room.
MMD-AP0721H
(60Hz)
69 (Pa)
137 (Pa)
196 (Pa)
Outside still pressure
69 (Pa)
137 (Pa)
196 (Pa)
Overall level A
48
49
50.5
Overall level A
48
49
50.5
54
55
57
55
50
58
C
(dB)
Octave band sound pressure level (dB)
(dB)
Octave band sound pressure level (dB)
(50Hz)
Outside still pressure
Audibility limits
of continous
white level
C
Audibility limits
of continous
white level
Octave band center frequency (Hz)
Octave band center frequency (Hz)
MMD-AP0961H
(50Hz)
69 (Pa)
137 (Pa)
196 (Pa)
Outside still pressure
69 (Pa)
137 (Pa)
196 (Pa)
Overall level A
49
50
51.5
Overall level A
49
50
51.5
56
59
61
57
59
61
C
Audibility limits
of continous
white level
Octave band center frequency (Hz)
(dB)
Octave band sound pressure level (dB)
(dB)
Octave band sound pressure level (dB)
(60Hz)
Outside still pressure
C
14
Audibility limits
of continous
white level
Octave band center frequency (Hz)
153
Sound level data (NC CURVE)
Sound level values shown are based on a measurement in a non resound room.
MMC-AP0151H
Fan Tap
H
M
L
Sound pressure
level(dB(A))
35
32
30
Octave band sound pressure level (dB)
90
Microphone
H
M
L
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
10
Audibility limits of
continous white sound
NC-20
~
75
~
150
~
300
~
600
~
1200
~
2400
~
4800
75
150
300
600
1200
2400
4800
9600
~
20
Octave band frequency (Hz)
MMC-AP0181H
MMC-AP0241H,AP0271H
Fan Tap
H
M
L
Fan Tap
H
M
L
Sound pressure
level(dB(A))
36
33
30
Sound pressure
level(dB(A))
38
36
33
90
H
M
L
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
continous white sound
10
NC-20
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
90
H
M
L
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
continous white sound
10
~
75
~
150
~
300
~
600
~
1200
~
2400
~
4800
~
20
~
75
~
150
~
300
~
600
~
1200
~
2400
~
4800
75
150
300
600
1200
2400
4800
9600
75
150
300
600
1200
2400
4800
9600
Octave band frequency (Hz)
MMC-AP0361H
MMC-AP0481H
Fan Tap
H
M
L
Fan Tap
H
M
L
Sound pressure
level(dB(A))
41
38
35
Sound pressure
level(dB(A))
43
40
37
90
H
M
L
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
continous white sound
NC-20
H
M
L
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
continous white sound
10
NC-20
~
75
~
150
~
300
~
600
~
1200
~
2400
~
4800
~
20
~
75
~
150
~
300
~
600
~
1200
~
2400
~
4800
75
150
300
600
1200
2400
4800
9600
75
150
300
600
1200
2400
4800
9600
Octave band frequency (Hz)
~
20
Octave band frequency (Hz)
154
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
90
10
~
20
Octave band frequency (Hz)
14
NC-20
Sound level data (NC CURVE)
MMK-AP0071H, AP0091H, AP0121H
Fan Tap
Sound pressure
level(dB(A))
H
M
L
39
34
31
Octave band sound pressure level (dB)
90
Microphone
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
M
M
30
Audibility limits
of continous
white level
20
NC-30
L
NC-20
10
60
125
250
500
1000
2000
4000
8000
Octave band frequency (Hz)
MMK-AP0151H, AP0181H
Fan Tap
Sound pressure
level(dB(A))
MMK-AP0241H
H
M
L
42
38
35
Fan Tap
Sound pressure
level(dB(A))
M
L
38
35
90
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
H
M
30
NC-30
L
Audibility limits
of continous
white level
20
NC-20
10
Octave band sound pressure level (dB)
90
Octave band sound pressure level (dB)
H
42
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
H
M
30
NC-30
L
Audibility limits
of continous
white level
20
NC-20
10
63
125
250
500
1000
2000
Octave band frequency (Hz)
4000
8000
63
125
250
500
1000
2000
4000
8000
14
Octave band frequency (Hz)
155
Sound level data (NC CURVE)
Sound level values shown are based on a measurement in a non resound room.
Microphone
MML-AP0071BH, AP0091BH, AP0121BH
50Hz
H
M
L
60Hz
Fan Tap
A
36.0
34.0
32.0
Overall level
A
36.0
34.0
32.0
41.7
40.2
37.9
(dB)
C
41.6
39.8
38.1
(standard sound pressure 0.0002 µbar)
Audibility limits
of continous white level
Fan Tap
(standard sound pressure 0.0002 µbar)
Audibility limits
of continous white level
Octave band center frequency (Hz)
50Hz
H
M
L
60Hz
Fan Tap
H
M
L
Overall level
A
36.0
34.0
32.0
Overall level
A
36.0
34.0
32.0
(dB)
C
41.4
40.0
38.8
(dB)
C
41.4
40.0
39.0
(standard sound pressure 0.0002 µbar)
Audibility limits
of continous white level
Octave band center frequency (Hz)
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
L
C
MML-AP0151BH, AP0181BH
156
M
(dB)
Octave band center frequency (Hz)
14
H
Overall level
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
Fan Tap
(standard sound pressure 0.0002 µbar)
Audibility limits
of continous white level
Octave band center frequency (Hz)
MML-AP0241BH
50Hz
Fan Tap
H
M
L
60Hz
Fan Tap
M
L
Overall level
A
42.0
37.0
33.0
Overall level
A
42.0
37.0
33.0
(dB)
C
46.4
41.0
37.7
(dB)
C
46.6
41.0
38.0
(standard sound pressure 0.0002 µbar)
Audibility limits
of continous white level
Octave band center frequency (Hz)
(standard sound pressure 0.0002 µbar)
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
H
Audibility limits
of continous white level
Octave band center frequency (Hz)
14
157
Sound level data (NC CURVE)
Sound level values shown are based on a measurement in a non resound room.
MMY-MAP0501HT8, MAP0501HT7, MAP0501T8
Octave band sound pressure level(dB)
Sound pressure Level (dB(A))
Microphone
55
90
Cooling
Heating
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
continous white sound
10
20~75
75~150
150~300
NC-20
300~600
600~1200
1200~2400
2400~4800 4800~10000
Octave band frequency(Hz)
MMY-MAP0601HT8, MAP0601HT7, MAP0601T8
56
Sound pressure Level (dB(A))
90
Cooling
Heating
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
continous white sound
10
20~75
75~150
150~300
Octave band sound pressure level(dB)
Octave band sound pressure level(dB)
Sound pressure Level (dB(A))
MMY-MAP0801HT8, MAP0801HT7, MAP0801T8
90
Cooling
Heating
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
continous white sound
NC-20
300~600
600~1200
1200~2400
10
20~75
2400~4800 4800~10000
75~150
Octave band frequency(Hz)
58
Cooling
Heating
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
continous white sound
75~150
150~300
NC-20
300~600
600~1200
1200~2400
2400~4800 4800~10000
Octave band frequency(Hz)
158
600~1200
Sound pressure Level (dB(A))
90
10
20~75
NC-20
300~600
1200~2400
2400~4800 4800~10000
MMY-MAP1201HT8, MAP1201HT7, MAP1201T8
Octave band sound pressure level(dB)
Octave band sound pressure level(dB)
14
150~300
Octave band frequency(Hz)
MMY-MAP1001HT8, MAP1001HT7, MAP1001T8
Sound pressure Level (dB(A))
57
59
90
Cooling
Heating
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
continous white sound
10
20~75
75~150
150~300
NC-20
300~600
600~1200
1200~2400
2400~4800 4800~10000
Octave band frequency(Hz)
Sound level data (NC CURVE)
Sound level values shown are based on a measurement in a non resound room.
MMY-AP1401HT8, AP1401HT7, AP1401T8
59.5
Sound pressure Level (dB(A))
90
Cooling
Heating
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
continous white sound
10
20~75
75~150
150~300
NC-20
300~600
600~1200
1200~2400
Octave band sound pressure level(dB)
Octave band sound pressure level(dB)
Sound pressure Level (dB(A))
MMY-AP1601HT8, AP1601HT7, AP1601T8
Octave band frequency(Hz)
80
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
continous white sound
75~150
150~300
Octave band sound pressure level(dB)
Octave band sound pressure level(dB)
Heating
10
20~75
70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
continous white sound
600~1200
1200~2400
75~150
80
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
150~300
NC-20
300~600
600~1200
1200~2400
2400~4800 4800~10000
Octave band frequency(Hz)
Octave band sound pressure level(dB)
Octave band sound pressure level(dB)
Heating
75~150
61
Heating
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
continous white sound
75~150
150~300
NC-20
300~600
600~1200
Sound pressure Level (dB(A))
61.5
Audibility limits of
continous white sound
2400~4800 4800~10000
1200~2400
2400~4800 4800~10000
MMY-AP2211HT8, AP2211HT7, AP2211T8
Cooling
10
20~75
1200~2400
Octave band frequency(Hz)
MMY-AP2201HT8, AP2201HT7, AP2201T8
70
600~1200
80
10
20~75
2400~4800 4800~10000
90
NC-20
300~600
Cooling
Octave band frequency(Hz)
Sound pressure Level (dB(A))
150~300
90
NC-20
300~600
NC-70
Sound pressure Level (dB(A))
Cooling
70
Heating
80
MMY-AP2001HT8, AP2001HT7, AP2001T8
60.5
90
Cooling
Octave band frequency(Hz)
MMY-AP1801HT8, AP1801HT7, MAP1801T8
Sound pressure Level (dB(A))
90
10
20~75
2400~4800 4800~10000
60
61.5
90
Cooling
Heating
80
70
NC-70
14
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
continous white sound
10
20~75
75~150
150~300
NC-20
300~600
600~1200
1200~2400
2400~4800 4800~10000
Octave band frequency(Hz)
159
Sound level data (NC CURVE)
Sound level values shown are based on a measurement in a non resound room.
MMY-AP2401HT8, AP2401HT7, AP2401T8
62
Sound pressure Level (dB(A))
90
Cooling
Heating
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
continous white sound
10
20~75
75~150
150~300
Octave band sound pressure level(dB)
Octave band sound pressure level(dB)
Sound pressure Level (dB(A))
MMY-AP2411HT8, AP2411HT7, AP2411T8
90
600~1200
1200~2400
Cooling
Heating
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
continous white sound
NC-20
300~600
10
20~75
2400~4800 4800~10000
75~150
Octave band frequency(Hz)
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
continous white sound
NC-20
300~600
600~1200
1200~2400
2400~4800 4800~10000
Octave band frequency(Hz)
Octave band sound pressure level(dB)
14
63
90
Cooling
Heating
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
continous white sound
10
20~75
75~150
150~300
NC-20
300~600
600~1200
1200~2400
2400~4800 4800~10000
Octave band frequency(Hz)
160
1200~2400
2400~4800 4800~10000
62.5
90
Cooling
Heating
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
continous white sound
10
20~75
75~150
150~300
NC-20
300~600
600~1200
1200~2400
2400~4800 4800~10000
Octave band frequency(Hz)
MMY-AP3001HT8, AP3001HT7, AP3001T8
Sound pressure Level (dB(A))
Octave band sound pressure level(dB)
Octave band sound pressure level(dB)
Heating
150~300
600~1200
Sound pressure Level (dB(A))
Cooling
75~150
NC-20
300~600
MMY-AP2801HT8, AP2801HT7, AP2801T8
62
90
10
20~75
150~300
Octave band frequency(Hz)
MMY-AP2601HT8, AP2601HT7, AP2601T8
Sound pressure Level (dB(A))
62
Sound level data (NC CURVE)
Sound level values shown are based on a measurement in a non resound room.
MMY-AP3201HT8, AP3201HT7, AP3201T8
63
Sound pressure Level (dB(A))
90
Cooling
Heating
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
continous white sound
10
20~75
75~150
150~300
Octave band sound pressure level(dB)
Octave band sound pressure level(dB)
Sound pressure Level (dB(A))
MMY-AP3211HT8, AP3211HT7, AP3211T8
90
600~1200
1200~2400
Cooling
Heating
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
continous white sound
NC-20
300~600
10
20~75
2400~4800 4800~10000
63
75~150
150~300
NC-20
300~600
600~1200
1200~2400
2400~4800 4800~10000
Octave band frequency(Hz)
Octave band frequency(Hz)
MMY-AP3401HT8, AP3401HT7, AP3401T8
MMY-AP3411HT8, AP3411HT7, AP3411T8
63.5
90
Sound pressure Level (dB(A))
Cooling
Heating
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
continous white sound
10
20~75
75~150
150~300
Octave band sound pressure level(dB)
Octave band sound pressure level(dB)
Sound pressure Level (dB(A))
90
600~1200
1200~2400
Cooling
Heating
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
continous white sound
NC-20
300~600
10
20~75
2400~4800 4800~10000
63.5
75~150
150~300
NC-20
300~600
600~1200
1200~2400
2400~4800 4800~10000
Octave band frequency(Hz)
Octave band frequency(Hz)
MMY-AP3601HT8, AP3601HT7, AP3601T8
MMY-AP3611HT8, AP3611HT7, AP3611T8
63.5
90
Sound pressure Level (dB(A))
Cooling
Heating
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
continous white sound
10
20~75
75~150
150~300
NC-20
300~600
600~1200
1200~2400
2400~4800 4800~10000
Octave band frequency(Hz)
Octave band sound pressure level(dB)
Octave band sound pressure level(dB)
Sound pressure Level (dB(A))
64
90
Cooling
Heating
80
70
NC-70
14
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
continous white sound
10
20~75
75~150
150~300
NC-20
300~600
600~1200
1200~2400
2400~4800 4800~10000
Octave band frequency(Hz)
161
Sound level data (NC CURVE)
Sound level values shown are based on a measurement in a non resound room.
MMY-AP3801HT8, AP3801HT7, AP3801T8
64
Sound pressure Level (dB(A))
90
Cooling
Heating
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
continous white sound
10
20~75
75~150
150~300
Octave band sound pressure level(dB)
Octave band sound pressure level(dB)
Sound pressure Level (dB(A))
MMY-AP4001HT8, AP4001HT7, AP4001T8
90
600~1200
1200~2400
Cooling
Heating
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
continous white sound
NC-20
300~600
10
20~75
2400~4800 4800~10000
75~150
NC-20
300~600
600~1200
1200~2400
2400~4800 4800~10000
Octave band frequency(Hz)
MMY-AP4201HT8, AP4201HT7, AP4201T8
MMY-AP4401HT8, AP4401HT7, AP4401T8
Sound pressure Level (dB(A))
Octave band sound pressure level(dB)
Cooling
Heating
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
continous white sound
10
20~75
75~150
150~300
Octave band sound pressure level(dB)
64.5
90
NC-20
300~600
600~1200
1200~2400
Cooling
Heating
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
continous white sound
10
20~75
75~150
2400~4800 4800~10000
MMY-AP4601HT8, AP4601HT7, AP4601T8
Heating
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
continous white sound
150~300
NC-20
300~600
600~1200
1200~2400
600~1200
Sound pressure Level (dB(A))
Cooling
75~150
NC-20
300~600
2400~4800 4800~10000
Octave band frequency(Hz)
1200~2400
2400~4800 4800~10000
MMY-AP4801HT8, AP4801HT7, AP4801T8
65
90
10
20~75
150~300
Octave band frequency(Hz)
Octave band sound pressure level(dB)
Octave band sound pressure level(dB)
Sound pressure Level (dB(A))
64.5
90
Octave band frequency(Hz)
162
150~300
Octave band frequency(Hz)
Sound pressure Level (dB(A))
14
64
65
90
Cooling
Heating
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
continous white sound
10
20~75
75~150
150~300
NC-20
300~600
600~1200
1200~2400
2400~4800 4800~10000
Octave band frequency(Hz)
15
Dimensional drawing
163
Foreword
164
15 Dimensional drawing
Foreword
Indoor unit
4-way Air Discharge Cassette Type
MMU-AP0091H to P0561H
860 to 910
ceiling open dimension
254.5
346.5
790 hanging bolt pitch
950
panel external dimension
415
Suction grille (Air suction port)
Electric parts box
Air discharge port (4-way)
o
35..
381.6
723 hanging bolt pitch
Z
860 to 910
ceiling open dimension
950
panel external dimension
For branch duct knockout square hole O/ 150
(2 positions at right side)
Refrigerant pipe
connecting port
840
(Gas)
250 70
Refrigerant pipe
Drain discharge port
270
connecting port
105
(Liquid)
45
113
174
Model
AP0091H to AP0301H
AP0361H to AP0561H
Bottom face of ceiling
15 or more
Stand-up
850 or less
Indoor unit
Bottom face of ceiling
(NOTE)
As ABS is used for the drain discharge
port of the main unit, the vinyl chloride
paste cannot be used.
Use the flexible hose (Band fix)
included in the package.
64
Knockout for flesh air intake
For O
/ 100
Z view
Drain-up standing-up size
120
2.7
Wired remote controller
RBC-AMT21E
RBC-AMT31E 4
Simple wired remote controller
RBC-AS21E
RBC-AS21E2
Wireless remote controller kit
TCB-AX21U(W)-E
TCB-AX21U(W)-E2
16
120
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
1000 or more
A
250
319
mm
B
120
183
1000 or more
1000 or more
Bottom face
of ceiling
57
8
.5
57 5
2
18
Stand-up
640 or less
360
15 or more
Bottom face of ceiling
30
Space required for installation and servicing
200
Check port
( 450)
Check port
( 450)
200
88
130
210
A
97 B
35
840
480
227
105
Hanging bolt
M10 or W3/8 local arrange
15
165
2-way Air Discharge Cassette Type
MMU-AP0071WH, AP0091WH, AP0121WH
Z view
Center of panel
Center of main unit
Air discharge port
(2-way)
1000
Electric parts box
95
650
Hanging bolt
pitch 480
Unit external
dimension 550
Ceiling open
dimension 620
Panel external
dimension 650
35
Air discharge port
(2-way)
30
Unit external dimension
830
Hanging bolt pitch
880
Ceiling open dimension
960
Panel external dimension
1000
156
398
1000
or more
1000
or more
Ceiling panel
(Procured by locally)
Indoor unit
Bottom face of ceiling
166
Wired remote controller
RBC-AMT21E
RBC-AMT31E
Simple wired remote controller
RBC-AS21E
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E
TCB-AX21E2
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
Z
Bottom face of ceiling
Branch duct knockout hole
(Also on opposite side)
Refrigerant pipe
connecting port
(Gas side O
/ 9.5)
100
Refrigerant pipe
connecting port
(Liquid side O
/ 6.4)
35
Drain pipe connecting port
Inner O
/ 32, Nominal O/ 25
for vinyl chloride pipe
56
75 55
Pour water port
O
/ 150
78
508mm or less
100mm
or less
160mm or less
Space required for installation and servicing
60
210
Power supply
connecting port
35
178
242
282
348
Obstruction
00
O/ 2
8
1000 or more
222
Ceiling
15
Hanging bolt
4-M10 procured locally
265
53
5mm
or more
Knockout hole for taking-in air
(Only at reverse side)
Foreword
MMU-AP0151WH, AP0181WH, AP0241WH, AP0271WH, AP0301WH
Z view
Center of main unit
Center of panel
Air discharge port
(2-way)
Electric parts box
Air suction port
(2-way)
650
Hanging bolt
pitch 480
Unit external
dimension 550
Ceiling open
imension 620
Panel external
dimension 650
95
35
30
Unit external dimension 1350
Hanging bolt pitch 1400
Ceiling open dimension 1480
Panel external dimension 1520
Obstruction
1000
or more
1000
or more
Space required for installation and servicing
222
156
Ceiling
60
8
398
5mm
or more
1000 or more
0
¯ 20
53
Hanging bolt
4-M10 procured locally
295
Ceiling panel
(Procured locally)
Bottom face of ceiling
Z
508mm or less
Bottom face of ceiling
Drain pipe connecting port
Inner O
/ 3̄2, Nominal O/ 25
for vinyl chloride pipe
75
55
Pour water port
Refrigerant pipe
connecting port
(Gas side O
/ B)
56
Refrigerant pipe
connecting port
100
(Liquid side OA)
/
35
¯ 150
78
Wired remote controller
RBC-AMT21E
RBC-AMT31E
Simple wired remote controller
RBC-AS21E
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E
TCB-AX21E2
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
210
Power supply
connecting port
35
178
242
282
348
100mm
or less
160mm or less
Branch duct knockout hole
(Also on opposite side)
Knockout hole for taking-in air
(Only at reverse side)
B
Model
A
MMU-AP0151WH to AP0181WH O
/ 6.4 O/ 12.7
MMU-AP0241WH to AP0301WH O
/ 9.5 O/ 15.9
15
167
MMU-AP0481WH
Z view
Center of panel
Center of main unit
Air suction port
(2-way)
680
Ceiling open
dimension 650
Panel external
dimension 680
Hanging bolt
pitch 510
Unit external
dimension 620
5
95
Air discharge port
(2-way)
1898
Electric parts box
105
Unit external dimension 1650
Hanging bolt pitch 1700
Ceiling open dimension 1850
Panel external dimension 1898
1000
Obstruction or more
1000
or more
Space required for installation and servicing
68
¯2
00
¯2
00
230
166
Ceiling
60
8
406
5mm
or more
1000 or more
Hanging bolt
4-M10 procured locally
150
455
Ceiling panel
(Procured locally)
Z
Bottom face of ceiling
15
Drain pipe connecting port
(VP25)
75
55
Pour water port
50
¯1
15
186
250
290
356
Bottom face of ceiling
Refrigerant pipe
connecting port
(Gas side O
/ 15.9)
Refrigerant pipe
56
connecting port
100
(Liquid side O
/ 9.5)
86
516mm or less
100mm
or less
160mm or less
Branch duct knockout hole
(Also on reverse side)
4
168
Wired remote controller
RBC-AMT21E
RBC-AMT31E
Simple wired remote controller
RBC-AS21E
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E
16
120
TCB-AX21E2
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
120
15
2.7
210
Power supply
Knockout hole for taking-in air
connecting port
(Only at reverse side)
1-way Air Discharge Cassette Type
MMU-AP0071YH, AP0091YH, AP0121YH
Panel external dimension 1050
Drain pipe connecting port
(VP25)
20
Power supply
connecting port
Panel external
dimension 470
Ceiling open
dimension 430
20
Ceiling open dimension 1010
Center of panel
Hanging bolt
4-M10 procured locally
Support
metal
Refrigerant pipe connecting port
(Gas side) 9.5
Discharge louver
Refrigerant pipe connecting port
(Liquid side) 6.4
Ceiling panel
Procured by locally
Air discharge port
Bottom face of ceiling
Panel mounting hole
5 positions
Air suction port
Dimensions
Model MMU-
A
B
C
AP0071YH, AP0091YH, AP0121YH
235
245
200
B
or more
120
2.7
Wired remote controller
4
RBC-AMT21E
RBC-AMT31E
Simple wired remote controller
RBC-AS21E
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E
100 or more
100 or more
200 or more
TCB-AX21E2
Weekly timer
application
120
16
RBC-AMT31E and RBC-EXW21E2
Space required for installation and servicing
15
169
MMU-AP0151SH, AP0181SH, AP0241SH
150 knockout hole (For air intake)
18
96
0
Panel external dimension A
Ceiling open dimension B
Center of panel
Pitch 200
N
20
110
10
H
755
Air discharge port
Power supply
connecting port
10
130
100
100
Z view
440
335
255
160
120
100
10
F
Z
198
E
80
80
60
50
A
125
530
655
D
30
C
65
Suction port
30
Ceiling open
dimension 695
Panel external
dimension 755
30
30
20
G
100
Refrigerant pipe connecting port
(Liquid side) I
Knockout hole for discharge forward
Refrigerant pipe connecting port
(Gas side) J
Drain pipe connecting port
(VP25)
Z
Dimensions
A
B
C
D
E
F
G
AP0151SH, AP0181SH
1220
1160
545
485
530
470
AP0241SH
1420
1360
645
585
630
570
200 or more
Model MMU-
170
I
J
N
254
800
6.4
12.7
4
460
1000
9.5
15.9
5
Wired remote controller
1000 or more
1000 or more
4
Ceiling
RBC-AMT21E
Obstacle
RBC-AMT31E
Simple wired remote controller
Space required for installation and servicing
RBC-AS21E
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E
TCB-AX21E2
Weekly timer application
120
16
RBC-AMT31E and RBC-EXW21E2
120
2.7
15
1000 or more
H
Concealed Duct Standard Type
MMD-AP0071BH, AP0091BH, AP0121BH, AP0151BH, AP0181BH, AP0241BH,
AP0271BH, AP0301BH, AP0361BH, AP0481BH, AP0561BH
Drain pipe connecting port
(Inner O
/ 32 vinyl chloride pipe VP25 connection)
Unit external dimension
40
800
Hanging bolt pitch
700
59
25
41
Hanging bolt pitch A
7.5
50
638
498
393
B
41
Refrigerant pipe
connecting port
(Gas side O/ F)
215
44
49
70 to 270
10-O
/ 4 tapping screw
O
/ 160
142
C
131
50
knockout hole
(For air intake)
(When attaching
directly)
O
/ 125
91
150
Air
Discharge
Refrigerant pipe
connecting port
(Liquid side O/ G)
50
243
Hanging bolt 4-M10
(Procured locally)
O
/ 26
power supply,
remote controller
wires drawing-out
port
196
Air
Suction
Panel C, L
Ceiling opening
470
240
Ceiling open
dimension D
E
Air Suction
Model
MMD-
AP0071BH, AP0091BH, AP0121BH
AP0151BH, AP0181BH
AP0241BH, AP0271BH, AP0301BH
AP0361BH, AP0481BH, AP0561BH
A
616
766
1066
1416
B
550
700
1000
1350
C
350
500
800
1150
(Note)
Two of f high efficiency filters available.
Deodorant filter not available.
(Note)
Be sure to create a check port at position A as indicated
in the following figure. This is for maintenance of the equipment.
Air outlet
Ceiling opening part
D
600
750
1050
1400
E
470
620
920
1270
F
9.5
12.7
15.9
15.9
G
6.4
9.4
9.5
9.5
Wired remote controller
RBC-AMT21E
RBC-AMT31E
Simple wired remote controller
RBC-AS21E
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E
TCB-AX21E2
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
Check port B
450mm
Air filter
700mm for maintenance of air filter
271mm or less
300mm
Check port A
450mm
550mm or less
(150mm)
15
100mm or less
Drain-up piping
700mm for
maintenance of air filter
171
Concealed Duct High Static Pressure Type
MMD-AP0181H, AP0241H, AP0271H, AP0361H, AP0481H, AP0721H, AP0961H
MMD-AP0181H to AP0361H
MMD-AP0481H
710
(Hanging bolt mounting pitch 800)
Hole for hanging bolt
(4-O/ 12 x 72)
Power supply/
communication
piping port (O/ 26)
(Under electric parts box)
Electric parts box
Hole for hanging bolt
(4-O/ 12 x 72)
Power supply/
communication
piping port (O/ 26)
(Under electric parts box)
Refrigerant pipe connecting port
(Liquid side O/ A)
Refrigerant pipe connecting port
(Gas side O/ B)
Electric parts box
Refrigerant pipe connecting port
(Liquid side O/ 9.5)
Refrigerant pipe connecting port
(Gas side O/ 15.9)
Screw hole for duct
mounting (6-M6)
Air suction port
Drain pipe connecting port
(VP25)
Screw hole for duct
mounting (8-M6)
Air suction port
Drain pipe connectingport
(VP25)
Z view
Z view
Air discharge port
Screw hole for duct
mounting (8-M6)
Air discharge port Screw hole for duct
mounting (6-M6)
AP0181H to AP0271H type
AP0361H type
Model MMDAP0181H
AP0241H, AP0271H, AP0361H, AP0481H
A
6.4
9.5
B
12.7
15.9
Space required for installation and servicing *1
Service space
Service space
1288
(Hanging bolt mounting pitch)
1328
Refrigerant pipe connecting port
(Gas side O/ A)
65
370
Drain pipe connecting port
(VP25)
Model MMD-
Gas pipe O/ A
AP0721H
O
/ 22.2
AP0961H
O
/ 22.2
120
Screw hole for duct Suction port
mounting (10-M6)
250 250 250 250 190
Wired remote controller
RBC-AMT21E
RBC-AMT31E
Simple wired4remote controller
RBC-AS21E
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E
TCB-AX21E2
Weekly timer application
120and RBC-EXW21E2
16
RBC-AMT31E
2.7
35
470
31
624
698
406
190 250 250 250 250
200 150
45
1380
Refrigerant pipe connecting port
(Liquid side O/ 12.7)
Discharge port
Screw hole for duct
mounting (10-M6)
172
*1 Service space requirement for MMD-AP0721H and AP0961H are
different from those in the above figure. For details make enquiries
to your dealer.
Electric parts box
1250
15
Check port
600
100
1260
(Hanging bolt mounting pitch)
MMD-AP0721H, AP0961H
Long hole for
hanging bolt
(4-O/ 12 92)
Air discharge port
500 mm or more
Screw hole for duct
mounting (4-M6)
600 mm
or more
Z view
Under Ceiling Type
MMC-AP0151H, AP0181H, AP0241H, AP0271H, AP0361H, AP0481H
Upper piping drawing-out port (Knockout)
70
Piping drawing-out port
(Knockout port)
Drain port VP20
(Inner diam. O
/ 26, hose supplied)
Left drain size
Drain pipe
connecting port
B (Hanging position)
Refrigerant pipe (Liquid side O
/ D)
Refrigerant pipe (Gas side O
/ C)
Model MMC-
A
A
B
C
D
AP0151H, AP0181H
910
855
12.7
6.4
AP0241H to AP0271H
1180
1125
15.9
9.5
AP0361H, AP0481H
1595
1540
15.9
9.5
Wireless sensor
mounting section
(Optional)
Ceiling surface
Unit
250 or more
250 or more
(Front side to be positioned horizontally.)
500
or more
Within 50
Hanging bolt
Space required for installation and servicing
Remote controller cable taking-in port
Wired remote controller
Power supply taking-in port
RBC-AMT21E
(Knockout hole)
RBC-AMT31E
4
Remote controller cable taking-in port
(Knockout)
Simple wired remote controller
RBC-AS21E
RBC-AS21E2
Wireless remote controller kit
RBC-AX22CE
Air taking-in port
RBC-AX22CE2
(Duct sold separately) (Knockout hole O
/ 92)
Weekly timer application
Drain left piping drawing-out port
Piping hole on the wall
120
(Knockout)
(O
/ 100 hole)
16
RBC-AMT31E
and RBC-EXW21E2
120
2.7
320 170
(Hanging position)
Power supply cable taking-in port
(Knockout)
Remote controller piping
taking-in port (Knockout hole)
15
173
High Wall Type
MMK-AP0071H, AP0091H, AP0121H
Position of holes on the installation plate.
Long hole for
wooden screw
15-6 x 30
690 (Installation plate)
Hole for anchor bolt
10-10 x 20 long hole
(Including installation plate)
210
Including installation plate (Accessory)
Earth screw (M4)
(Inside of electric parts box)
Upper end of installation plate
Refrigerant pipe
connecting port
O
Gas side 9.5
/ 9.5
Drain pipe
connecting port
Air suction port
Discharge port
(Air direction upward/downward/leftward/rightward are adjustable.)
Piping port from left/right sides
(Knockout)
30 or more
Gas pipe 440
Liquid pipe 540
Drain pipe 560
At shipment
(When drawing pipe from left)
300 or more
300 or more
Space required for service
Wired remote controller
RBC-AMT21E
RBC-AMT31E
4
Simple wired remote controller
RBC-AS21E
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E
TCB-AX21E2
Weekly timer application
120
16
RBC-AMT31E and RBC-EXW21E2
174
120
2.7
15
Refrigerant pipe
connecting port
Liquid side O/ 6.4
MMK-AP0151H, AP0181H
Position of holes on the installation plate
182.5
690 (Installation plate)
hole for
wooden screw
15-6 x 30
182.5
Hole for anchor bolt
10-10 x 20 long hole
Upper end of installation plate
(Including installation plate)
210
Including installation plate (Accessory)
Earth screw (M4)
(Inside of electric parts box)
Refrigerant pipe
Refrigerant pipe
connecting port
connecting port
Liquid side O/ 6.4
Gas side O/ 12.7
Air suction port
Air discharge port
(Air direction upward/downward/leftward/rightward is adjustable.)
Drain pipe
connecting port
Piping port from left/right sides
(Knockout)
30 or more
Gas pipe 440
Liquid pipe 540
Drain pipe 560
At shipment
(When drawing pipe from left)
Wired remote controller
RBC-AMT21E
300 or more
300 or more
RBC-AMT31E
Space required for service
Simple wired remote controller
RBC-AS21E
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E
TCB-AX21E2
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
15
175
MMK-AP0241H
Position of holes on the installation plate
hole for
wooden screw
21-6 x 30
170
1090 (Installation plate)
Hole for anchor bolt
16-10 x 20 long hole
170
(Including installation plate)
210
Including installation plate (Accessory)
Earth screw (M4)
(Inside of electric parts box)
Upper end of installation plate
Refrigerant pipe
connecting port
Gas side O/ 15.9
Air discharge port (Air direction upward/ Air suction port
downward/leftward/rightward are adjustable.)
Drain pipe
connecting port
Piping port from left/right sides
(Knockout)
30 or more
Gas pipe 440
Liquid pipe 540
Drain pipe 560
At shipment
(When drawing pipe from left)
300 or more
15
176
Refrigerant pipe
connecting port
Liquid side O/ 9.5
300 or more
Wired remote controller
Space required for service
RBC-AMT21E
RBC-AMT31E
Simple wired remote controller
RBC-AS21E
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E
TCB-AX21E2
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
Floor Standing Cabinet Type
MML-AP0071H, AP0091H, AP0121H, AP0151H, AP0181H, AP0241H
Lower refrigerant piping port
(50 x 100 knockout hole)
130
Fixing hole (Floor)
(2-O/ 10)
Operation switch section
(Sold separately)
Fixing hole (Floor)
(Two off knockout holes O/ 10-O/ 20)
Air discharge port
Hole fixing wall
(2-10 x 24 long hole)
Air suction port
Refrigerant pipe port
(50 x 100 knockout hole)
( left100
side )
Power supply cord hole
(O/ 26 knockout on both sides)
Dimensions
Model MMC-
A
B
AP0071H, AP0091H, AP0121H
O
/ 9.5
O
/ 6.4
AP0151H, AP0181H
O
/ 12.7
O
/ 6.4
AP0241H
O
/ 15.9
O
/ 9.5
Earth screw
(M6)
Refrigerant pipe port
(O/ 130 knockout hole)
Wired remote controller
RBC-AMT21E
RBC-AMT31E
Simple wired remote controller
RBC-AS21E
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E
TCB-AX21E2
Weekly timer application
RBC-AMT31E and
RBC-EXW21E2
Refrigerant pipe
connecting port
(Liquid side O/ B)
Refrigerant pipe
connecting port
(Gas side O/ A)
Drain pipe connecting port
(O/ 20)
Space required for service
Figure shows piping at the left side
Positional
drawing of piping
500
(Front side) or more
15
300
or more
1000 or more
Wall
Wall
(Front side)
177
Floor Standing Concealed Type
MML-AP0071BH, AP0091BH, AP0121BH, AP0151BH, AP0181BH, AP0241BH
Fixing hole (Floor)
(Discharge port size in flange)
Ceiling board section
150
or more
(Service space)
150
or more
(Air discharge port size in flange)
(Service space)
2-O/ 4.7 hole
(Left/right side each)
Expansion
valve box
G-O/ 4.7 hole
(Front side and rear side each)
4-O/ 15 hole
(For mounting rear side)
2-12 x 18 hole
Fixing hole (floor)
Name
Pipe connecting port at liquid side (O/ E)
Dimensions
Pipe connecting port at gas side (O/ F)
Electric parts box
(Earth terminal is on the inside)
Air filter
Model MMLAP0151BH, AP0181BH
AP0241BH
4
15
178
A
AP0071BH, AP0091BH, AP0121BH
B
C
D
610 580 550
4
910 880 850
7
Wired remote controller
RBC-AMT21E
RBC-AMT31E
Simple wired remote controller
RBC-AS21E
RBC-AS21E2
120
16
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
120
Drain pipe connecting port (20A)
2.7
No.
E
6.4
9.5
F
G
9.5
5
12.7
15.9
8
Floor Standing Type
MMF-AP0151H, AP0181H, AP0241H, AP0271H
Wall
of installing distance
( Incase
)
is 50mm from wall
Dimensions
Model
Lower refrigerant piping port
(50 x 120 Knockout hole)
Installation plate
Discharge
port
A
B
MMF-AP0151H, AP0181H O/ 12.7
O
/ 6.4
MMF-AP0241H, AP0271H O/ 15.7
O
/ 9.5
600
30 x 3 30 x 3
80
Wall
Wall
a
b
Wall
Control
part
More
Front than
500
Front
More than
1000
Wall
More than
200
Space required for service
(In case of right side piping )
Control
cover
Wall
Floor
Refrigerant piping port (Both side)
(O/ 80 Knockout)
Earth screw (M4)
Drain
hose
Installation plate
Suction port
Refrigerant piping hole (Back side)
(O/ 130 Knockout)
Refrigerant piping hole (Bottom side)
(50 x 120 Knockout)
Refrigerant piping position
Refrigerant piping joint
(Gas side A)
Wired remote controller
RBC-AMT21E
RBC-AMT31E
Simple wired remote controller
RBC-AS21E
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E
TCB-AX21E2
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
Refrigerant piping joint
(Liquid side B)
Details of hole for lower side piping
(
)
O
/ 130
In case b 1773
2- lower hole
For M8 Screw bolt
or M8 Anchor bolt
In case a 1770
Details of hole for back side piping
Knockout
(For backside piping)
15
4- lower hole
M8 Screw bolt
( For
or M8 Anchor bolt )
50 x 120 (Square)
(For under surface piping)
179
MMF-AP0361H, AP0481H, AP0561H
Wall
Incase of installing distance is
( 50mm
)
from wall
Lower refrigerant piping port
(50 x 120 Knockout)
Installation plate
Discharge
port
600
30 x 3 30 x 3
80
Wall
Wall
a
b
Wall
Control
part
Control
cover
More
Front than
500
Wall
Front
More than
1000
Wall
More than 200
Space required for service
(In case of right side piping )
Floor
Refrigerant piping port (Both side)
(O
/ 80 Knockout)
Drain hose
Installation plate
Earth screw (M4)
Dtain hose
Suction port
Refrigerant piping hole
(Back side)
(O
/ 130 Knockout)
Refrigerant piping hole (Bottom side)
(50 x 120 Knockout)
Refrigerant piping position
Gas side
Refrigerant piping joint
(Gas side O
/ 19)
Liquid
side
Wired remote controller
RBC-AMT21E
RBC-AMT31E
Simple wired remote controller
RBC-AS21E
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E
TCB-AX21E2
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
Refrigerant piping joint
(Liquid side O
/ 9.5)
2- lower hole
M8 Screw bolt
( For
or M8 Anchor bolt )
In case b 1773
15
In case a 1770
Details of hole for back side piping
O
/ 130 Knockout
(For backside piping)
180
Details of hole for lower side piping
4- lower hole
For M8 Screw bolt
or M8 Anchor bolt
(
)
50 x 120 (Square)
(For under surface piping)
Outdoor module
(NOTES)
1. If there is an obstacle above the outdoor unit,
ensure there is a minimum space of 2000mm or more above the
unit.
2. Any obstacle around the perimeter of the outdoor unit must be
kept 800mm or less.
3. Draw out the locally supplied piping at the front of the outdoor unit
horizontally, keep a minimum of 500mm or more. between the
outdoor unit and traversing pipe If the pipework is to be installed
in this method.
790
(including steady leg)
755
anchor bolt pitch
750
MMY-MAP0501T8, MAP0601T8, MAP0801T8, MAP1001T8, MAP1201T8
MMY-MAP0501HT8, MAP0601HT8, MAP0801HT8, MAP1001HT8, MAP1201HT8
MMY-MAP0501HT7, MAP0601HT7, MAP0801HT7, MAP1001HT7, MAP1201HT7
700
anchor bolt pitch
4-15 x 20
(Long hole)
990
A
165
Applied model
B
C
MMY-MAP0501T8, MAP0501HT8, MAP0501HT7 O/ 15.9 O/ 9.5
280
MMY-MAP0601T8, MAP0601HT8, MAP0601HT7 O/ 19.1 O/ 9.5
280
MMY-MAP0801T8, MAP0801HT8, MAP0801HT7 O/ 22.2 O/ 12.7 (205)
MMY-MAP1001T8, MAP1001HT8, MAP1001HT7 O/ 22.2 O/ 12.7 (205)
1800
1640
MMY-MAP1201T8, MAP1201HT8, MAP1201HT7 O/ 28.6 O/ 12.7 (205)
*1 Cutting position of L-shape pipe when pipe
700
Refrigerant pipe
connecting port
(Gas side) A
at gas side is connected
(Recommended pipe connecting position)
1750
or more
500
or more
*
Refrigerant pipe
connecting port
(Liquid side) B
Balance pipe
connecting port O
/ 9.5
Front side
(For work and service)
10 or more
10 or more
Space required for service
Knockout hole for
power piping (O
/ 48)
Balance pipe
connecting port
115
88
Square hole
64 125
136
140
215
Refrigerant pipe
connecting port
(Liquid side)
135
88
155
67 55
Front side
Front side
Front side
800
or less
Foundation
700
anchor bolt pitch
(Note 3)
600 (1000 or more) 500
600
or more or more
or more
630
80
610
Knockout for
control piping (O
/ 27)
100
MMY-MAP0501T8
MMY-MAP0501T8
MMY-MAP0501HT8
MMY-MAP0601HT8
MMY-MAP0601HT7
MMY-MAP0601HT7
Front side
Front side
500
or more
755
anchor bolt pitch
Foundation
C
80
100
Earth-attaching section of bottom plate
(Note 3)
500 (1000 or more) 500
600
or more or more
or more
500
500
or more
2-60 x 150 square hole
(Hole for handling goods)
1
88
241
C
1010 or more
15
20
Refrigerant pipe connecting port
(Gas side)
225
230
173
Details of front pipe/cabling holes
Details of hole for piping at lower side (Plane view)
52
181
Two units connected
MMY-AP1401T8, AP1601T8, AP1801T8, AP2001T8, AP2211T8, AP2411T8
MMY-AP1401HT8, AP1601HT8, AP1801HT8, AP2001HT8, AP2211HT8, AP2411HT8
MMY-AP1401HT7, AP1601HT7, AP1801HT7, AP2001HT7, AP2211HT7, AP2411HT7
(NOTES)
1. If there is an obstacle above the outdoor unit,
ensure there is a minimum space of 2000mm or more above the unit.
2. Any obstacle around the perimeter of the outdoor unit must be
kept 800mm or less.
3. Draw out the locally supplied piping at the front of the outdoor unit
horizontally, keep a minimum of 500mm or more. between the
outdoor unit and traversing pipe If the pipework is to be installed
in this method.
4. Arrange each of the outdoor units in order of their capacity.
_ Follower)
(Header >
20 or more
990
750
755
anchor bolt pitch
790
(including steady leg)
990
(310)
700
anchor bolt pitch
2
8-15 x 20
(Long hole)
88
700
1800
1640
165
1
700
anchor bolt pitch
2000
Combination outdoor unit
Combination unit
Header
Follower
MMY-AP1401T8, AP1401HT8, AP1401HT7 MMY-MAP0801T8, MAP0801HT8, MAP0801HT7 MMY-MAP0601T8, MAP0601HT8, MAP0601HT7
MMY-AP1601T8, AP1601HT8, AP1601HT7 MMY-MAP0801T8, MAP0801HT8, MAP0801HT7 MMY-MAP0801T8, MAP0801HT8, MAP0801HT7
MMY-AP1801T8, AP1801HT8, AP1801HT7 MMY-MAP1001T8, MAP1001HT8, MAP1001HT7 MMY-MAP0801T8, MAP0801HT8, MAP0801HT7
MMY-AP2001T8, AP2001HT8, AP2001HT7 MMY-MAP1001T8, MAP1001HT8, MAP1001HT7 MMY-MAP1001T8, MAP1001HT8, MAP1001HT7
MMY-AP2211T8, AP2211HT8, AP2211HT7 MMY-MAP1201T8, MAP1201HT8, MAP1201HT7 MMY-MAP1001T8, MAP1001HT8, MAP1001HT7
Front side Front side
1750mm or more
(Note 4)
500mm or more
500mm
or more
(Note 3)
(Note 4)
(1000 or more) 500
600 or more or more
Front side Front side
Front side Front side
600
or more
Front side Front side
Front side Front side
500
or more
15
(Note 4)
(Note 3)
(Note 4)
500 (1000 or more) 500
or more 600 or more or more
MMY-AP2411T8, AP2411HT8, AP2411HT7 MMY-MAP1201T8, MAP1201HT8, MAP1201HT7 MMY-MAP1201T8, MAP1201HT8, MAP1201HT7
10mm or more
20mm or more
Front side (For work and service)
182
800
or less
800
or less
2020mm or more
Space required for service
10mm
or more
Three units connected
MMY-AP2201T8, AP2401T8, AP2601T8, AP2801T8, AP3001T8, AP3211T8,
AP3411T8, AP3611T8
MMY-AP2201HT8, AP2401HT8, AP2601HT8, AP2801HT8, AP3001HT8,
AP3211HT8, AP3411HT8, AP3611HT8
MMY-AP2201HT7, AP2401HT7, AP2601HT7, AP2801HT7,
AP3001HT7, AP3211HT7, AP3411HT7, AP3611HT7
990
20 or more
990
20 or more
990
750
755
anchor bolt pitch
790
(including steady leg)
(NOTES)
1. If there is an obstacle above the outdoor unit,
ensure there is a minimum space of 2000mm or more
above the unit.
2. Any obstacle around the perimeter of the outdoor unit
must be kept 800mm or less.
3. Draw out the locally supplied piping at the front of the
outdoor unit horizontally, keep a minimum of 500mm or
more. between the outdoor unit and traversing pipe If the
pipework is to be installed in this method.
4. Arrange each of the outdoor units in order of their capacity.
_ Follower 3 )
_ Follower 2 >
(Header >
(310)
700
anchor bolt pitch
2
700
anchor bolt pitch
3
12-15 x 20
(Long hole)
88
700
1800
1640
165
1
(310)
700
anchor bolt pitch
3010
Combination outdoor unit
Combination unit
MMY-MAP0601T8, HT8, HT7
MMY-AP2401T8, HT8, HT7
MMY-MAP0801T8, HT8, HT7
MMY-MAP0801T8, HT8, HT7
MMY-MAP0801T8, HT8, HT7
MMY-AP2601T8, HT8, HT7
MMY-MAP1001T8, HT8, HT7
MMY-MAP0801T8, HT8, HT7
MMY-MAP0801T8, HT8, HT7
MMY-AP2801T8, HT8, HT7
MMY-MAP1001T8, HT8, HT7
MMY-MAP1001T8, HT8, HT7
MMY-MAP0801T8, HT8, HT7
MMY-AP3001T8, HT8, HT7
MMY-MAP1001T8, HT8, HT7
MMY-MAP1001T8, HT8, HT7
MMY-MAP1001T8, HT8, HT7
MMY-AP3221T8, HT8, HT7
MMY-MAP1201T8, HT8, HT7
MMY-MAP1001T8, HT8, HT7
MMY-MAP1001T8, HT8, HT7
MMY-AP3411T8, HT8, HT7
MMY-MAP1201T8, HT8, HT7
MMY-MAP1201T8, HT8, HT7
MMY-MAP1001T8, HT8, HT7
MMY-AP3611T8, HT8, HT7
MMY-MAP1201T8, HT8, HT7
MMY-MAP1201T8, HT8, HT7
MMY-MAP1201T8, HT8, HT7
3030mm or more
1750mm or more
500mm
or more
Front side (For work and service)
(Front side)
500
or more
Front side Front side Front side
10mm or more 20mm or more 20mm or more
10mm
or more
15
Space required for service
800
or less
800
or less
Front side Front side Front side
Front side Front side Front side
Front side Front side Front side
Front side Front side Front side
(Rear side)
MMY-MAP0801T8, HT8, HT7
(Note 4)
500mm or more
Follower
MMY-MAP0801T8, HT8, HT7
(Note 3)
600 (1000 or more) (Note 4)
or more 600 or more 500 or more
Follower
MMY-AP2201T8, HT8, HT7
(Note 4)
(Note 3)
(Note 4)
(1000 or more)
500 or more 600 or more 500 or more
Header
183
Four units connected
MMY-AP3201T8, AP3401T8, AP3601T8, AP3801T8, AP4001T8, AP4201T8,
AP4401T8, AP4601T8, AP4801T8
MMY-AP3201HT8, AP3401HT8, AP3601HT8, AP3801HT8, AP4001HT8,
AP4201HT8, AP4401HT8, AP4601HT8, AP4801HT8
MMY-AP3201HT7, AP3401HT7, AP3601HT7, AP3801HT7, AP4001HT7,
AP4201HT7, AP4401HT7, AP4601HT7, AP4801HT7
20 or more
990
20 or more
20 or more
990
990
750
755
anchor bolt pitch
790
(including steady leg)
990
700
anchor bolt pitch
(310)
700
anchor bolt pitch
700
(310)
anchor bolt pitch
2
700
anchor bolt pitch
3
16-15 x 20
(Long hole)
4
88
700
1800
1640
165
1
(310)
4020
500mm
or more
15
)
(Note 4)
(Note 3)
(1000 or more) 500
600
600 or more or more
or more
Follower
MMY-MAP0801T8,
MMY-MAP0801T8,
MMY-MAP0801T8,
MMY-MAP0801T8,
MMY-MAP1001T8,
MMY-MAP1001T8,
MMY-MAP1001T8,
MMY-MAP1001T8,
MMY-MAP1201T8,
Front side Front side Front side Front side
Front side Front side Front side Front side
Front side Front side Front side Front side
10mm or more
20mm or more
20mm or more
20mm or more
Front side (For work and service)
4040mm or more
184
HT7
HT7
HT7
HT7
HT7
HT7
HT7
HT7
HT7
500
or more
Front side Front side Front side Front side
Front side Front side Front side Front side
HT8,
HT8,
HT8,
HT8,
HT8,
HT8,
HT8,
HT8,
HT8,
HT8,
HT8,
HT8,
HT8,
HT8,
HT8,
HT8,
HT8,
HT8,
HT7
HT7
HT7
HT7
HT7
HT7
HT7
HT7
HT7
10mm
or more
1750mm or more
(
HT7
HT7
HT7
HT7
HT7
HT7
HT7
HT7
HT7
800
or less
(NOTES)
1. If there is an obstacle above the
outdoor unit, ensure there is a
minimum space of 2000mm or
more above the unit.
2. Any obstacle around the
perimeter of the outdoor unit
must be kept 800mm or less.
3. Draw out the locally supplied
piping at the front of the
outdoor unit horizontally, keep a
minimum of 500mm or more.
between the outdoor unit and
traversing pipe If the pipework
is to be installed in this method.
4. Arrange each outdoor unit in
order of its capacity.
_
_ Follower 2 >
Header >
_ Follower 4
Follower 3 >
HT8,
HT8,
HT8,
HT8,
HT8,
HT8,
HT8,
HT8,
HT8,
500mm
or more
HT7
HT7
HT7
HT7
HT7
HT7
HT7
HT7
HT7
Combination outdoor unit
Follower
Follower
MMY-MAP0801T8, HT8, HT7
MMY-MAP0801T8,
MMY-MAP0801T8, HT8, HT7
MMY-MAP0801T8,
MMY-MAP1001T8, HT8, HT7
MMY-MAP0801T8,
MMY-MAP1001T8, HT8, HT7
MMY-MAP1001T8,
MMY-MAP1001T8, HT8, HT7
MMY-MAP1001T8,
MMY-MAP1001T8, HT8, HT7
MMY-MAP1001T8,
MMY-MAP1201T8, HT8, HT7
MMY-MAP1001T8,
MMY-MAP1201T8, HT8, HT7
MMY-MAP1201T8,
MMY-MAP1201T8, HT8, HT7
MMY-MAP1201T8,
800
or less
HT8,
HT8,
HT8,
HT8,
HT8,
HT8,
HT8,
HT8,
HT8,
(Note 3)
(Note 4) (1000 or more) (Note 4)
500 or more 600 or more 500 or more
MMY-AP3201T8,
MMY-AP3401T8,
MMY-AP3601T8,
MMY-AP3801T8,
MMY-AP4001T8,
MMY-AP4201T8,
MMY-AP4401T8,
MMY-AP4601T8,
MMY-AP4801T8,
Header
MMY-MAP0801T8,
MMY-MAP1001T8,
MMY-MAP1001T8,
MMY-MAP1001T8,
MMY-MAP1001T8,
MMY-MAP1201T8,
MMY-MAP1201T8,
MMY-MAP1201T8,
MMY-MAP1201T8,
(Note 4)
Combination unit
Space required for service
Branch header/Branch joint
Branch header
RBM-HY1043E, HY1083E, HY2043E, HY2083E
Gas side
A
80 x n
50
C
B
Insulator
Liquid side
A
80 x n
B
61
B
74.5
Insulator
Model
RBM-HY1043E
RBM-HY1083E
RBM-HY2043E
RBM-HY2083E
Gas side
A
B
380
90
Liquid side
360
60
Gas side
700
90
Liquid side
680
60
Gas side
385.5
95.5
Liquid side
360
60
Gas side
705.5
95.5
Liquid side
680
60
C
O
/D
O
/E
n
,
Accessory soket Q ty
83.6
_
22.2
15.9
3
6 x 4, 9 x 4, 14 x 1, 18 x 1, 70 x 1
15.9
9.5
3
1 x 4, 6 x 1, 9 x 1
83.6
_
22.2
15.9
7
6 x 8, 9 x 8, 14 x 1, 18 x 1, 70 x 1
15.9
9.5
7
1 x 8, 6 x 1, 9 x 1
89.3
_
31.8
15.9
3
6 x 2, 9 x 2, 27 x 1, 59 x 1
15.9
9.5
3
1 x2
89.3
_
31.8
15.9
7
6 x 7, 9 x 7, 27 x 1, 59 x 1
15.9
9.5
7
1 x7
T-shape branch joint
RBM-BT13E
Balance pipe
Liquid side
Gas side
O
/ 38.1
O
/ 22.2
10
14
14
7
13
O
/ 9.5
O
/ 9.5
10
26
O
/ 22.2
O
/ 22.2
O
/ 38.1
O
/ 38.1
39
14
O
/ 9.5
7
10
7
32
52
78
15
,
Accessory soket Q ty
Gas side
Liquid side
61 x 1, 62 x 1, 71 x 2, 73 x 2, 74 x 1,
14 x 2, 18 x 1, 85 x 2, 86 x 1
185
Y-shape branch joint
RBM-BY53E, BY103E
Liquid side
O
/D
B
O
/B
O
/D
O
/C
O
/C
O
/D
O
/D
Gas side
Insulator
Insulator
A
A
RBM-BY203E, BY303E
Liquid side
O
/D
Insulator
A
15
RBM-BY103E
RBM-BY203E
RBM-BY303E
186
A
,
Accessory soket Q ty
Model
RBM-BY53E
Insulator
250
80
15.9 12.7
5 x 2, 54 x 2, 9 x 1, 51 x 1
Liquid side 200
70
12.7
1 x 2, 5 x 1
350
80
22.2 19.1
7 x 1, 10 x 1, 13 x 2, 18 x 1, 52 x 2, 70 x 1, 89 x 1
Liquid side 250
80
15.9 12.7
2 x 1, 5 x 2, 6 x 1, 9 x 1, 54 x 1
350
80
31.8 28.6
16 x 1, 20 x 1, 27 x 1, 43 x 2, 48 x 1, 49 x 1, 58 x 1, 59 x 1
Liquid side 250
80
15.9 15.9
3 x 1, 6 x 1, 9 x 2
Gas side
Gas side
Gas side
Gas side
9.5
400 110 38.1 38.1
Liquid side 350
80
22.2 19.1
61 x 3, 62 x 2, 71 x 2, 73 x 1, 74 x 1, 75 x 1, 76 x 1, 77 x 1
4 x 1, 7 x 1, 10 x 1, 13 x 2, 14 x 1, 18 x 1, 52 x 1
B
O
/D
O
/C
B
O
/C
O
/D
O
/D
Gas side
Accessory socket
1
2
O
/ 6.4
5
54
24
O
/B
A
A
O
/ 9.5
Outer dia
O
/ 12.7
O
/B
2
29 6.4
5
26 9.5
54
31 15.9
4
39 6.4
Outer dia
3
6
9
51
4
O
/B
O
/B
7
39 9.5
36 12.7
32 9.5
13
33 15.9
9
28 12.7
52
43 22.2
51
38 19.1
89
53 28.6
6
O
/ 19.1
Outer dia
14 18 70 85 86
16 20 43 48 49 58
O
/B
A
O
/B
O
/B
A
O
/B
14
40 15.9
16
50 15.9
18
40 19.1
20
52 19.1
70
54 28.6
43
50 22.2
85
41 12.7
48
54 9.5
86
44 9.5
49
52 12.7
58
62 34.9
A
A
A
10
35 6.4
A
A
O
/B
3
Outer dia
O
/ 22.2
10 13 52 89
O
/B
A
O
/ 15.9
7
Outer dia
O
/ 28.6
Outer dia
27 59
61 62 73 74 75 76 77
O
/B
A
A
O
/B
A
O
/ 31.8
Outer dia
O
/B
27
49 28.6
59
59 34.9
O
/ 38.1
A
O
/B
61
55 34.9
62
66 41.3
71
66 28.6
73
66 22.2
74
66 19.1
75
64 15.9
76
62 12.7
77
62 9.5
15
Outer dia
187
188
16
Specifications
189
Foreword
190
16 Specifications
Foreword
TECHNICAL SPECIFICATIONS
50Hz
Indoor unit (50Hz specification)
4-way Air Discharge Cassette Type
MMU- AP0091H AP0121H AP0151H AP0181H AP0241H AP0271H AP0301H AP0361H AP0481H AP0561H
Model name
Cooling/Heating capacity (Note 1)
(kW)
2.8/3.2
3.6/4.0
7.1/8.0
8.0/9.0
9.0/10.0
11.2/12.5 14.0/16.0 16.0/18.0
(A)
0.17
0.19
0.21
0.24
0.35
0.59
0.81
0.83
Power consumption (kW)
0.020
0.022
0.026
0.032
0.048
0.070
0.110
0.112
(A)
0.30
0.33
0.36
0.42
0.59
0.87
1.23
1.26
Running current
Starting current
Heat-insulating material attached Zinc hot dipping steel plate
Main unit
Appearance
5.6/6.3
1 phase 50Hz 230V (220 - 240V) (Separate power supply for indoor units is required.)
Power supply
Electrical
characteristics
4.5/5.0
Ceiling
Panel
RBC-U21PG (W) -E
Model
Moon white (Munsell/2.5GY 9.0/0.5)
Panel colour
Height
(mm)
Main unit Width
(mm)
840
Depth
(mm)
840
Height
(mm)
35
Width
(mm)
950
Depth
(mm)
950
Outer
dimension
Ceiling
panel
Main unit
(kg)
Ceiling panel
(kg)
256
20
319
22
23
28
Total weight
4.5
Heat exchanger
Finned tube
Soundproof/Heat-insulating
material
Non-flammable insulation
Turbo fan
Fan
Fan unit
Standard air flow High
(m3/h)
(Mid./Low)
Motor
800
(730/680)
930
(830/790)
1,050
(920/800)
(W)
1,200
(920/820)
1,320
1,680
2,040
2,090
(1,110/850) (1,300/1,070) (1,430/1,130) (1,520/1,230)
60
90
Standard filter (Long life filter)
Air filter
Remote controller
Controller
Gas side
Connecting
Liquid side
pipe
(mm)
O
/ 9.5
(mm)
O
/ 12.7
O
/ 9.5
O
/ 6.4
Drain port (Nominal dia. mm)
Sound pressure level(Note 2)
(High/Mid./Low)
(dB(A))
O
/ 15.9
25 (Polyvinyl chloride tube)
30/29/27
31/29/27
32/29/28
34/31/28
37/33/30
40/36/33
44/38/34 45/40/34
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in
the actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
O
O
O
16
O
O
O
191
50Hz
2-way Air Discharge Cassette Type
MMU- AP0071WH AP0091WH AP0121WH AP0151WH AP0181WH AP0241WH AP0271WH AP0301WH
Model name
Cooling/Heating capacity
(kW)
2.2/2.5
2.8/3.2
3.6/4.0
4.5/5.0
Running current
8.0/9.0
9.0/10.0
14.0/16.0
1 phase
50Hz 220V
(A)
0.31
0.32
0.46
0.47
1.16
Electrical
Power
characteristics consumption
(kW)
0.070
0.072
0.105
0.106
0.250
Power factor
(%)
99
98
98
0.89
0.98
1.33
Starting current
(A)
97
0.47
Main unit
Appearance
Ceiling
panel
0.60
Heat-insulating material attached
Model
RBC-UW136PG
Main
unit
Panel colour
Outer
dimension
Width
(mm)
Depth
(mm)
Total weight
Width
(mm)
Depth
(mm)
398
1,350
1,650
550
620
8
1,520
1,000
1,898
680
650
(kg)
33
Ceiling panel
(kg)
8
44
48
52
11
Heat exchanger
18
Finned tube
Non-flammable insulation
Soundproof/Heat-insulating material
Centrifugal fan
Fan
Motor
406
830
Main unit
Standard air flow
Fan unit (High/Mid./Low)
RBCUW466PG
Light ivory (Munsell 10Y 9/0.5)
Height (mm)
Ceiling
panel
Zinc hot dipping steel plate
RBC-UW266PG
Height (mm)
(m3/h)
(W)
570/510/450
780/700/600
53
39
Air filter
1260/1140/960 1920/1500/1050
1140/960/720
53
92
Standard filter (Long life filter)
Remote controller
Controller
Gas side
Connecting
Liquid side
pipe
(mm)
O
/ 9.5
O
/ 12.7
Sound pressure level(Note 2)
(High/Mid./Low)
(dB(A))
O
/ 15.9
O
/ 9.5
O
/ 6.4
(mm)
Drain port (Nominal dia. mm)
25 (Polyvinyl chloride tube)
34/32/30
35/33/30
38/35/33
40/37/34
45/42/39
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in
the actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
O
O
192
7.1/8.0
1 phase 50Hz 230V (220 - 240V) (Separate power supply for indoor units is required.)
Power supply
16
5.6/6.3
AP0481WH
China only
O
O
O
O
Foreword
50Hz
1-way Air Discharge Cassette Type
Model name
MMU-
Cooling/Heating capacity (Note 1)
(kW)
Running current
Power consumption
Power factor
Starting current
Ceiling
panel
AP0121YH
AP0151SH
AP0181SH
AP0241SH
2.2/2.5
2.8/3.2
3.6/4.0
4.5/5.0
5.6/6.3
7.1/8.0
(A)
0.24
0.48
0.55
(kW)
0.053
0.103
0.115
(%)
95
93
91
(A)
0.6
0.8
1.1
Heat-insulating material attached
Main unit
Appearance
AP0091YH
1 phase 50Hz 230V (220 - 240V) (Separate power supply for indoor units is required.)
Power supply
Electrical
characteristics
(Note 2)
AP0071YH
Model
Zinc hot dipping steel plate
RBC-UY135PG
RBC-US165PG
RBC-US265PG
W : Silky shade (1Y8.5/0.5)
Panel colour
Height
(mm)
235
Width
(mm)
850
Depth
(mm)
400
655
Height
(mm)
18
10
Width
(mm)
1,050
Depth
(mm)
470
Main unit
(kg)
22
27
31
Ceiling panel
(kg)
3.5
8
9
780/720/660
1,200/1,140/1,020
Main unit
Outer
dimension
Ceiling
panel
198
1,000
1,200
1,220
1,420
755
Total weight
Heat exchanger
Finned tube
Soundproof/Heat-insulating material
Non-flammable insulation
Centrifugal fan
Fan
Fan
unit
Standard air flow (High/Mid./Low)
Motor
(m3h)
(W)
540/480/420
34
22
Controller
Remote controller
Room thermostat
Attached
Air filter
Connecting
pipe
Standard filter (Long life filter)
Gas side
(mm)
Liquid side
(mm)
Drain port
O
/ 9.5
O
/ 12.7
O
/ 9.5
O
/ 6.4
(Nominal dia. mm)
Sound pressure level(Note 2)(High/Mid./Low) (dB(A))
O
/ 15.9
25 (Polyvinyl chloride tube)
42/39/34
42/39/35
43/41/37
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in
the actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
O
O
O
16
O
O
O
193
50Hz
Concealed Duct Type
MMD- AP0071BH AP0091BH AP0121BH AP0151BH AP0181BH AP0241BH AP0271BH AP0301BH AP0361BH AP0481BH AP0561BH
Model name
Cooling/Heating capacity (Note 1) (kW)
2.2/2.5
2.8/3.2
4.5/5.0
5.6/6.3
7.1/8.0
8.0/9.0
9.0/10.0 11.2/12.5 14.0/16.0 16.0/18.0
1 phase 50Hz 230V (220 - 240V) (Separate power supply for indoor units is required.)
Power supply
Electrical
characteristics
3.6/4.0
(A)
0.29
0.34
0.43
0.52
0.61
0.83
0.98
Power consumption(kW)
0.033
0.039
0.050
0.060
0.071
0.107
0.128
0.5
0.59
0.75
0.90
1.05
1.44
1.70
Running current
Starting current
(A)
Appearance Main unit
Zinc hot dipping steel plate
Height
(mm)
Main unit Width
(mm)
Depth
(mm)
800
Height
(mm)
9
Width
(mm)
Depth
(mm)
Outer
dimension
Suction
ceiling
panel
320
700
550
780
630
1,000
1,350
1,080
1,430
500
Main unit
(kg)
28
32
43
55
Ceiling panel
(kg)
3.5
4
6
7
Total weight
Heat exchanger
Finned tube
Non-flammable insulation
Soundproof/Heat-insulating material
Centrifugal fan
Fan
Standard air flow High
(Mid./Low)
(m3/h)
480
(420/340)
570
650
780
(490/400) (540/480) (660/540)
(W)
120
External static pressure
(factory setting)
(Pa)
50 (4 mmAq)
External static pressure
(Pa)
110 (10 mmAq)
Fan unit Motor
Air filter
Connecting
pipe
1,980
(1710/1490)
Remote controller
Gas side
(mm)
Liquid side
(mm)
O
/ 9.5
O
/ 12.7
Sound pressure level(Note 2)
(High/Mid./Low)
(dB(A))
O
/ 15.9
O
/ 6.4
O
/ 9.5
Drain port (Nominal dia. mm)
25 (Polyvinyl chloride tube)
30/28/26
31/29/27
32/30/28
33/31/29
34/32/29 36/34/32
36/34/32
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in
the actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
O
O
194
1,260
1,620
(1080/870) (1410/1200)
Standard filter (Long life filter)
Controller
16
1,140
(990/870)
O
O
O
O
50Hz
Concealed Duct High Static Pressure Type
Model name
MMD-
Cooling/Heating capacity (Note 1)
(kW)
AP0181H
AP0241H
AP0271H
AP0361H
AP0481H
AP0721H
AP0961H
5.6/6.3
7.1/8.0
8.0/9.0
11.2/12.5
14.0/16.0
22.4/25.0
28.0/31.5
1 phase 50Hz 230V (220 - 240V) (Separate power supply for indoor units is required.)
Power supply
Running current
Electrical
Power consumption
characteristics
Power factor
Starting current
(A)
0.81
1.35
1.63
1.84
5.25
5.52
(kW)
0.184
0.299
0.368
0.414
1.200
1.260
(%)
99
96
98
98
99
99
(A)
1.3
3.5
4.1
4.8
13.6
14.8
Appearance
Zinc hot dipping steel plate
Outer
Height x Width x Depth
dimension
(kg)
Total weight
380 x 850 x 660
(mm)
50
52
470 x 1,380 x 1,250
67
150
56
Finned tube
Heat exchanger
Soundproof/Heat-insulating material
Non-flammable insulation
Centrifugal fan
Fan
(m3/h)
Standard air flow
Fan
unit
380 x 1,200 x 660
900
1,320
1,600
2,100
260
160
Motor
(W)
External static pressure
(Factory setting)
(Pa)
137
External static pressure
(Pa)
68.6-137-196
Air flow limit
Lower limit/Upper limit
(m3/h)
720/1,080
3,600
1,060/1,580
1,280/1,920
Air filter
4,200
370 x 3
1,680/2,520
2,880/4,320
3,360/5,040
Option or field supply
Controller
Remote controller
Gas side
Connecting Liquid side
pipe
Drain port
(mm)
O
/ 12.7
O
/ 15.9
O
/ 22.2
(mm)
O
/ 6.4
O
/ 9.5
O
/ 12.7
(Nominal dia. mm)
Sound pressure level(Note 2)
(High/Mid./Low)
(dB(A))
25 (One side of male screw)
37
40
49
50
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in
the actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
O
O
O
O
O
O
16
195
50Hz
Under Ceiling Type
Model name
MMC-
Cooling/Heating capacity (Note 1)
(kW)
AP0151H
AP0181H
AP0241H
AP0271H
AP0361H
AP0481H
4.5/5.0
5.6/6.3
7.1/8.0
8.0/9.0
11.2/12.5
14.0/16.0
1 phase 50Hz 230V (220 - 240V) (Separate power supply for indoor units is required.)
Power supply
Electrical
characteristics
Running current
(A)
0.29
0.32
0.42
0.78
0.84
Power consumption (kW)
0.033
0.038
0.050
0.091
0.110
Starting current
0.43
0.48
0.62
1.17
1.25
(A)
Appearance
White (Munsell 10Y 9.3/0.4)
Outer
dimension Height x Width x Depth (mm)
210 x 910 x 680
210 x 1,180 x 680
210 x 1,595 x 680
22
26
34
(kg)
Total weight
Finned tube
Heat exchanger
Non-flammable insulation
Soundproof/Heat-insulating
material
Fan
Fan unit
Standard air flow
(High/Mid./Low)
Motor
Centrifugal fan
(m3/h)
720/600/540
(W)
780/660/540
30
Controller
1,110/900/840
1,650/1,380/1,2001,800/1,560/1,320
40
80
Remote controller
Room thermostat
Attached
Air filter
Standard filter (Long life filter)
Gas side
Connecting
Liquid side
pipe
(mm)
O
/ 12.7
O
/ 15.9
(mm)
O
/ 6.4
O
/ 9.5
Drain port (Nominal dia. mm)
Sound pressure level(Note 2)
(High/Mid./Low)
(dB(A))
20 (Polyvinyl chloride tube)
35/32/30
36/33/30
38/36/33
41/38/35
43/40/37
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in
the actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
O
O
16
196
O
O
O
O
50Hz
High Wall Type
Model name
MMK-
Cooling/Heating capacity (Note 1)
(kW)
Running current
Power consumption
AP0091H
AP0121H
AP0151H
AP0181H
AP0241H
2.2/2.5
2.8/3.2
3.6/4.0
4.5/5.0
5.6/6.3
7.1/8.0
1 phase 50Hz 230V (220 - 240V) (Separate power supply for indoor units is required.)
Power supply
Electrical
characteristics
AP0071H
(A)
0.30
0.32
0.35
(kW)
0.035
0.037
0.040
(A)
0.36
0.42
0.47
368 x 895 x 210
368 x 1,055 x 210
368 x 1,430 x 210
18
19
25
780/660/600
1,200/1,020/900
Starting current
Suction grille and side panel
Appearance
Outer
dimension
Silky mist (Munsell 1Y 8.9/0.5)
Discharge grille
City gray (Munsell N6.5)
Bottom surface
Silky mist (Munsell 1Y 8.9/0.5)
Height x Width x Depth
Total weight
(mm)
(kg)
Heat exchanger
Finned tube
Soundproof/Heat-insulating material
Non-flammable insulation
Fan
Cross-flow fan
Fan
unit Standard air flow (High/Mid./Low)
(m3/h)
600/540/480
(W)
Motor outlet
30
Air filter
Standard filter (Simple filter)
Remote controller
Controller
Gas side
(mm)
Connecting
Liquid side
(mm)
pipe
Drain port (Nominal dia. mm)
Sound pressure level(Note 2)
(High/Mid./Low)
(dB(A))
O
/ 12.7
O
/ 9.5
O
/ 15.9
O
/ 9.5
O
/ 6.4
20 (Polyvinyl chloride tube)
42/38/35
39/34/31
42/38/35
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in
the actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
O
O
O
O
O
O
16
197
50Hz
Floor Standing Cabinet Type
Model name
MML-
Cooling/Heating capacity (Note 1)
(kW)
Electrical
characteristics Power consumption
Power factor
Starting current
AP0091H
AP0121H
AP0151H
AP0181H
AP0241H
2.2/2.5
2.8/3.2
3.6/4.0
4.5/5.0
5.6/6.3
7.1/8.0
1 phase 50Hz 230V (220 - 240V) (Separate power supply for indoor units is required.)
Power supply
Running current
AP0071H
(A)
0.26
0.43
0.47
(kW)
0.056
0.092
0.102
(%)
94
93
94
(A)
0.60
0.80
1.10
Appearance
Outer
dimension
Silky shade (1Y8.5/0.5)
Height x Width x Depth
Total weight
630 x 950 x 230
(mm)
37
(kg)
40
Heat exchanger
Finned tube
Soundproof/Heat-insulating material
Non-flammable insulation
Fan
Centrifugal fan
Fan unit
Standard air flow
(High/Mid./Low)
Motor outlet
(m3/h)
900/780/650
480/420/360
(W)
1,080/930/780
70
45
Air filter
Standard filter (Simple filter)
Controller
Connecting
pipe
40
Remote controller
Gas side
(mm)
Liquid side
(mm)
O
/ 9.5
O
/ 12.7
O
/ 6.4
(dB(A))
O
/ 9.5
20 (Polyvinyl chloride tube)
Drain port (Nominal dia. mm)
Sound pressure level(Note 2)
(High/Mid./Low)
O
/ 15.9
39/37/35
45/41/38
49/44/39
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in
the actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
O
O
16
198
O
O
O
O
50Hz
Floor Standing Concealed Type
Model name
MML-
Cooling/Heating capacity (Note 1)
(kW)
Electrical
characteristics
Power consumption
Power factor
Starting current
AP0091BH
AP0121BH
AP0151BH
AP0181BH
AP0241BH
2.2/2.5
2.8/3.2
3.6/4.0
4.5/5.0
5.6/6.3
7.1/8.0
1 phase 50Hz 230V (220 - 240V) (Separate power supply for indoor units is required.)
Power supply
Running current
AP0071BH
(A)
0.25
0.45
0.46
(kW)
0.056
0.090
0.095
(%)
97
87
90
(A)
0.60
0.80
1.00
Appearance
Zinc hot dipping steel plate
Height x Width x
Depth
Outer
dimension
(mm)
(kg)
Total weight
600 x 745 x 220
600 x 1,045 x 220
21
29
Finned tube
Heat exchanger
Soundproof/Heat-insulating material
Non-flammable insulation
Centrifugal fan
Fan
Fan unit
Standard air flow
(High/Mid./Low)
Motor
Static pressure range
(m3/h)
(W)
460/400/300
740/600/490
19
70
(kPa)
0
Standard filter (Simple filter)
Air filter
Remote controller
Controller
Connecting
pipe
950/790/640
Gas side
(mm)
Liquid side
(mm)
O
/ 9.5
O
/ 12.7
O
/ 15.9
O
/ 6.4
Drain port (Nominal dia. mm)
O
/ 9.5
20 (One side of male screw)
Sound pressure level(Note 2)(High/Mid./Low)(dB(A))
36 (34/32)
42 (37/33)
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in
the actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
O
O
O
O
O
O
16
199
50Hz
Floor Standing Type
Model name
MMF-
Cooling/Heating capacity (Note 1)
(kW)
Electrical
Power consumption
characteristics
Power factor
Starting current
AP0181H
AP0241H
AP0271H
AP0361H
AP0481H
AP0561H
4.5/5.0
5.6/6.3
7.1/8.0
8.0/9.0
11.2/12.5
14.0/16.0
16.0/18.0
1 phase 50Hz 230V (220 - 240V) (Separate power supply for indoor units is required.)
Power supply
Running current
AP0151H
(A)
0.67
0.88
1.29
1.60
(kW)
0.150
0.190
0.280
0.350
(%)
97
(A)
0.90
94
1.10
Appearance
Height x Width x
Depth
(mm)
(kg)
Total weight
1750 x 600 x 210
2.10
1750 x 600 x 390
49
48
Heat exchanger
65
Finned tube
Soundproof/Heat-insulating material
Non-flammable insulation
Fan
Standard air flow
(High/Mid./Low)
Motor
Centrifugal fan
(m3/h)
(W)
900/780/660
1,200/1,020/840
1,920/1,680/1,380
2,160/1,860/1,560
37
63
11
16
Standard filter (Simple filter)
Air filter
Controller
Connecting
pipe
1.70
W : Silky shade (1Y 8.5/0.5)
Outer
dimension
Fan unit
95
Remote controller
Gas side
(mm)
O
/ 12.7
O
/ 15.9
Liquid side
(mm)
O
/ 6.4
O
/ 9.5
Drain port (Nominal dia. mm)
Sound pressure level(Note 2)(High/Mid./Low) (dB(A))
20 (One side of male screw)
46/43/38
49/45/40
51/48/44
54/50/46
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in
the actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
O
O
16
200
O
O
O
O
60Hz
Indoor unit (60Hz specifications)
4-way Air Discharge Cassette Type
Model name
MMU- AP0091H AP0121H AP0151H AP0181H AP0241H AP0271H AP0301H AP0361H AP0481H AP0561H
Cooling/Heating capacity (Note 1)
(kW)
2.8/3.2
3.6/4.0
Power supply
Starting current
7.1/8.0
8.0/9.0
(A)
0.22
0.26
0.37
0.61
0.85
0.87
0.020
0.022
0.026
0.032
0.048
0.070
0.110
0.112
0.30
0.33
0.36
0.42
0.59
0.87
1.23
1.26
Heat-insulating material attached
Zinc hot dipping steel plate
RBC-U21PG (W) -E
Model
Panel colour
Moon white (Munsell/2.5GY 9.0/0.5)
(mm)
Main unit Width
(mm)
840
Depth
(mm)
840
Height
(mm)
35
Width
(mm)
950
Depth
(mm)
950
Ceiling
panel
Main unit
(kg)
Ceiling panel
(kg)
Total weight
256
319
22
20
23
28
4.5
Heat exchanger
Finned tube
Soundproof/Heat-insulating
material
Non-flammable insulation
Fan
Turbo fan
Fan unit
Standard air flow High 3
(m /h)
(Mid./Low)
Motor
11.2/12.5 14.0/16.0 16.0/18.0
0.20
Height
Outer
dimension
9.0/10.0
0.18
Main unit
Ceiling
Panel
5.6/6.3
1 phase 60Hz 220V (Separate power supply for indoor units is required.)
(A)
Running current
Electrical
characteristics Power consumption (kW)
Appearance
4.5/5.0
800
(730/680)
930
1,050
(830/790) (920/800)
(W)
1,200
(920/820)
1,320
1,680
2,040
2,090
(1,110/850) (1,300/1,070) (1,430/1,130) (1,520/1,230)
60
Air filter
90
Standard filter (Long life filter)
Controller
Remote controller
Gas side
Connecting
Liquid side
pipe
(mm)
O
/ 9.5
(mm)
O
/ 12.7
O
/ 6.4
O
/ 9.5
Drain port (Nominal dia. mm)
Sound pressure level(Note 2)
(High/Mid./Low)
(dB(A))
O
/ 15.9
25 (Polyvinyl chloride tube)
30/29/27
31/29/27
32/29/28
34/31/28
37/33/30
40/36/33
44/38/34 45/40/34
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in
the actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
O
O
O
16
O
O
O
201
60Hz
2-way Air Discharge Cassette Type
Model name
MMU-
Cooling/Heating capacity
(kW)
Electrical
characteristics
AP0091WH
AP0121WH
AP0151WH
AP0181WH
AP0241WH
AP0271WH
AP0301WH
2.2/2.5
2.8/3.2
3.6/4.0
4.5/5.0
5.6/6.3
7.1/8.0
8.0/9.0
9.0/10.0
1 phase 60Hz 220V (Separate power supply for indoor units is required.)
Power supply
Running current
AP0071WH
(A)
0.33
0.38
0.53
0.58
Power
consumption
(kW)
0.070
0.076
0.115
0.123
Power factor
(%)
97
90
99
96
(A)
0.46
0.59
0.87
0.96
Heat-insulating material attached
Zinc hot dipping steel plate
Starting current
Main unit
Appearance
Ceiling
panel
Main
unit
Outer
dimension
Model
RBC-UW266PG
RBC-UW136PG
Panel colour
Light ivory (Munsell 10Y 9/0.5)
Height (mm)
398
Width
(mm)
Depth
(mm)
1.350
830
550
Height (mm)
Ceiling
panel
Width
(mm)
Depth
(mm)
8
1,520
1,000
650
Main unit
(kg)
33
Ceiling panel
(kg)
8
44
48
Total weight
11
Heat exchanger
Finned tube
Soundproof/Heat-insulating material
Non-flammable insulation
Centrifugal fan
Fan
Fan unit Standard air flow
(High/Mid./Low)
Motor
(m3/h)
(W)
570/510/450
780/700/600
1,140/960/720
53
39
53
Air filter
Standard filter (Long life filter)
Controller
Remote controller
Gas side
Connecting Liquid side
pipe
(mm)
O
/ 12.7
O
/ 9.5
(mm)
Sound pressure level(Note 2) (dB(A))
(High/Mid./Low)
O
/ 9.5
25 (Polyvinyl chloride tube)
35/33/30
34/32/30
38/35/33
40/37/34
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in
the actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
O
O
202
O
/ 15.9
O
/ 6.4
Drain port (Nominal dia.mm)
16
1,260/1,140/960
O
O
O
O
60Hz
1-way Air Discharge Cassette Type
Model name
MMU-
Cooling/Heating capacity (Note 1)
(kW)
Power supply
Running current
Electrical
characteristics
(Note 2)
Power consumption
Power factor
Starting current
Ceiling
panel
AP0091YH
AP0121YH
AP0151SH
AP0181SH
AP0241SH
2.2/2.5
2.8/3.2
3.6/4.0
4.5/5.0
5.6/6.3
7.1/8.0
1 phase 60Hz 220V (Separate power supply for indoor units is required.)
(A)
0.26
0.54
0.61
(kW)
0.056
0.115
0.130
(%)
98
97
97
(A)
0.60
0.80
1.10
Main unit
Appearance
AP0071YH
Heat-insulating material attached
Model
Zinc hot dipping steel plate
RBC-US165PG
RBC-UY135PG
Panel colour
RBC-US265PG
W : Silky shade (1Y8.5/0.5)
Height
(mm)
235
Width
(mm)
850
Depth
(mm)
400
655
Height
(mm)
18
10
Width
(mm)
1,050
Depth
(mm)
470
Main unit
(kg)
22
27
31
Ceiling panel
(kg)
3.5
8
9
780/720/660
1,200/1,140/1,020
Main unit
Outer
dimension
Ceiling
panel
198
1,000
1,200
1,220
1,420
755
Total weight
Heat exchanger
Finned tube
Soundproof/Heat-insulating material
Non-flammable insulation
Centrifugal fan
Fan
Fan Standard air flow (High/Mid./Low)
unit
Motor
(m3/h)
(W)
540/480/420
34
22
Controller
Remote controller
Room thermostat
Attached
Air filter
Connecting
pipe
Standard filter (Long life filter)
Gas side
(mm)
Liquid side
(mm)
Drain port
O
/ 12.7
O
/ 9.5
O
/ 9.5
O
/ 6.4
(Nominal dia. mm)
Sound pressure level(Note 2)(High/Mid./Low) (dB(A))
O
/ 15.9
25 (Polyvinyl chloride tube)
42/39/35
42/39/34
43/41/37
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in
the actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
O
O
O
16
O
O
O
203
60Hz
Concealed Duct Type
Model name
MMD- AP0071BH AP0091BH AP0121BH AP0151BH AP0181BH AP0241BH AP0271BH AP0301BH AP0361BH AP0481BH AP0561BH
Cooling/Heating capacity (Note 1) (kW)
2.2/2.5
2.8/3.2
4.5/5.0
5.6/6.3
7.1/8.0
8.0/9.0
9.0/10.0 11.2/12.5 14.0/16.0 16.0/18.0
1 phase 60Hz 220V (Separate power supply for indoor units is required.)
Power supply
Electrical
characteristics
3.6/4.0
(A)
0.30
0.35
0.45
0.55
0.64
0.87
1.03
Power consumption (kW)
0.033
0.039
0.050
0.060
0.071
0.107
0.128
0.5
0.59
0.75
0.90
1.05
1.44
1.70
Running current
(A)
Starting current
Appearance Main unit
Zinc hot dipping steel plate
320
Height
(mm)
Main unit Width
(mm)
Depth
(mm)
800
Height
(mm)
9
Width
(mm)
Depth
(mm)
Outer
dimension
Suction
ceiling
panel
550
700
630
780
1,000
1,350
1,080
1,430
500
Main unit
(kg)
28
32
43
55
Ceiling panel
(kg)
3.5
4
6
7
Total weight
Heat exchanger
Finned tube
Non-flammable insulation
Soundproof/Heat-insulating material
Centrifugal fan
Fan
Standard air flow High
(Mid./Low)
(m3/h)
480
(420/340)
570
650
780
(490/400) (540/480) (660/540)
(W)
120
External static pressure
(factory setting)
(Pa)
50 (4 mmAq)
External static pressure
(pa)
110 (10 mmAq)
Fan unit Motor
Air filter
Connecting
pipe
1,980
(1,710/1,490)
Remote controller
Gas side
(mm)
Liquid side
(mm)
O
/ 9.5
O
/ 12.7
Sound pressure level(Note 2)
(High/Mid./Low)
(dB(A))
O
/ 15.9
O
/ 6.4
O
/ 9.5
25 (Polyvinyl chloride tube)
Drain port(Nominal dia. mm)
30/28/26
31/29/27 31/29/27 32/30/28
33/31/29
34/32/29 36/34/32
38/36/32
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in
the actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
O
O
204
1,260
1,620
(1,080/870) (1,410/1,200)
Standard filter (Long life filter)
Controller
16
1,140
(990/870)
O
O
O
O
60Hz
Concealed Duct High Static Pressure Type
Model name
MMD-
Cooling/Heating capacity (Note 1)
(kW)
AP0181H
AP0241H
AP0271H
AP0361H
AP0481H
AP0721H
AP0961H
5.6/6.3
7.1/8.0
8.0/9.0
11.2/12.5
14.0/16.0
22.4/25.0
28.0/31.5
Power supply
Running current
Electrical
characteristics
Power consumption
Power factor
Starting current
1 phase 60Hz 220V (Separate power supply for indoor units is required.)
(A)
0.92
1.80
2.07
2.26
7.10
7.42
(kW)
0.198
0.385
0.450
0.490
1.540
1.610
(%)
98
97
(A)
1.30
3.40
Appearance
99
3.90
4.35
13.00
13.60
Zinc hot dipping steel plate
Outer
Height x Width x Depth
dimension
(mm)
(kg)
Total weight
380 x 850 x 660
50
380 x 1,200 x 660
470 x 1,380 x 1,250
67
150
56
52
Heat exchanger
Finned tube
Soundproof/Heat-insulating material
Non-flammable insulation
Fan
Centrifugal fan
Standard air flow
Fan
unit
99
(m3/h)
900
1,600
1,320
2,100
Motor
(W)
External static pressure
(Factory setting)
(Pa)
137
External static pressure
(Pa)
68.6-137-196
Air flow limit
Lower limit/Upper limit
(m3/h)
160
720/1,080
3,600
260
1,280/1,920
1,060/1,580
Air filter
4,200
370 x 3
1,680/2,520
2,880/4,320
3,360/5,040
Option or field supply
Controller
Remote controller
Gas side
Connecting Liquid side
pipe
(mm)
O
/ 12.7
O
/ 15.9
O
/ 22.2
(mm)
O
/ 6.4
O
/ 9.5
O
/ 12.7
Drain port (Nominal dia. mm)
Sound pressure level(Note 2)
(High/Mid./Low)
(dB(A))
25 (One side of male screw)
37
49
40
50
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in
the actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
O
O
O
O
O
O
16
205
60Hz
Under Ceiling Type
Model name
MMC-
Cooling/Heating capacity (Note 1)
(kW)
AP0151H
AP0181H
AP0241H
AP0271H
AP0361H
AP0481H
4.5/5.0
5.6/6.3
7.1/8.0
8.0/9.0
11.2/12.5
14.0/16.0
1 phase 60Hz 220V (Separate power supply for indoor units is required.)
Power supply
Electrical
characteristics
Running current
(A)
0.30
0.34
0.44
0.82
0.87
Power consumption (kW)
0.033
0.038
0.050
0.091
0.110
(A)
0.43
0.48
0.62
1.17
1.25
Starting current
White (Munsell 10Y 9.3/0.4)
Appearance
Outer
Height x Width x Depth (mm)
dimension
210 x 910 x 680
210 x 1,180 x 680
210 x 1,595 x 680
22
26
34
(kg)
Total weight
Heat exchanger
Finned tube
Soundproof/Heat-insulating material
Non-flammable insulation
Fan
Centrifugal fan
Fan unit
Standard air flow
(High/Mid./Low)
Motor
(m3/h)
780/660/540
720/600/540
30
(W)
1,110/900/840
1,650/1,380/1,2001,800/1,560/1,320
40
80
Remote controller
Controller
Attached
Room thermostat
Air filter
Standard filter (Long life filter)
Gas side
Connecting
Liquid side
pipe
(mm)
O
/ 12.7
O
/ 15.9
(mm)
O
/ 6.4
O
/ 9.5
Drain port(Nominal dia. mm)
Sound pressure level(Note 2)
(High/Mid./Low)
(db(A))
20 (Polyvinyl chloride tube)
35/32/30
36/33/30
38/36/33
41/38/35
43/40/37
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in
the actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
O
O
16
206
O
O
O
O
60Hz
High Wall Type
MMK-
Model name
Cooling/Heating capacity (Note 1)
(kW)
Power supply
Electrical
characteristics
Running current
Power consumption
Starting current
AP0071H
AP0091H
AP0121H
AP0151H
AP0181H
AP0241H
2.2/2.5
2.8/3.2
3.6/4.0
4.5/5.0
5.6/6.3
7.1/8.0
1 phase 60Hz 220V (Separate power supply for indoor units is required.)
(A)
0.32
0.34
0.35
(kW)
0.035
0.037
0.040
(A)
0.46
0.48
0.60
368 x 895 x 210
368 x 1,055 x 210
368 x 1,430 x 210
18
19
25
780/660/600
1,200/1,020/900
Silky mist (Munsell 1Y 8.9/0.5)
Suction grille and side panel
Appearance
Outer
dimension
Discharge grille
City gray (Munsell N6.5)
Bottom surface
Silky mist (Munsell 1Y 8.9/0.5)
Height x Width x Depth (mm)
(kg)
Total weight
Finned tube
Heat exchanger
Non-flammable insulation
Soundproof/Heat-insulating material
Cross-flow fan
Fan
Fan
Standard air flow (High/Mid./Low)
unit
(m3/h)
600/540/480
(W)
Motor outlet
30
Air filter
Standard filter (Simple filter)
Controller
Remote controller
Gas side
(mm)
Connecting
Liquid side
(mm)
pipe
Drain port (Nominal dia. mm)
Sound pressure level(Note 2)
(High/Mid./Low)
(dB(A))
O
/ 9.5
O
/ 12.7
O
/ 15.9
O
/ 6.4
O
/ 9.5
20 (Polyvinyl chloride tube)
39/34/31
42/38/35
42/38/35
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in
the actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
O
O
O
O
O
O
16
207
60Hz
Floor Standing Cabinet Type
Model name
MML-
Cooling/Heating capacity (Note 1)
(kW)
Power supply
Running current
Electrical
characteristics
Power consumption
Power factor
Starting current
AP0071H
AP0091H
AP0121H
AP0151H
AP0181H
AP0241H
2.2/2.5
2.8/3.2
3.6/4.0
4.5/5.0
5.6/6.3
7.1/8.0
1 phase 60Hz 220V (Separate power supply for indoor units is required.)
(A)
0.25
0.44
0.53
(kW)
0.053
0.092
0.113
(%)
96
95
97
(A)
0.60
0.80
1.10
Silky shade (1Y8.5/0.5)
Appearance
Outer
dimension
Height x Width x Depth
Total weight
(mm)
630 x 950 x 230
37
(kg)
40
Heat exchanger
Finned tube
Soundproof/Heat-insulating material
Non-flammable insulation
Fan
Centrifugal fan
Fan unit
Standard air flow
(High/Mid./Low)
Motor outlet
(m3/h)
480/420/360
900/780/650
45
(W)
70
Air filter
Standard filter (Simple filter)
Controller
Connecting
pipe
1,080/930/780
Remote controller
Gas side
(mm)
Liquid side
(mm)
O
/ 12.7
O
/ 9.5
O
/ 6.4
Drain port (Nominal dia. mm)
Sound pressure level(Note 2)
(High/Mid./Low)
(dB(A))
O
/ 15.9
O
/ 9.5
20 (Polyvinyl chloride tube)
39/37/35
45/41/38
49/44/39
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in
the actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
O
O
16
208
O
O
O
O
60Hz
Floor Standing Concealed Type
Model name
MML-
Cooling/Heating capacity (Note 1)
(kW)
Power supply
Running current
Power consumption
Electrical
characteristics
Power factor
Starting current
AP0071BH
AP0091BH
AP0121BH
AP0151BH
AP0181BH
AP0241BH
2.2/2.5
2.8/3.2
3.6/4.0
4.5/5.0
5.6/6.3
7.1/8.0
1 phase 60Hz 220V (Separate power supply for indoor units is required.)
(A)
0.27
0.46
0.51
(kW)
0.058
0.096
0.110
(%)
98
95
98
(A)
0.60
0.80
1.00
Appearance
Zinc hot dipping steel plate
Outer
dimension
Height x Width x
Depth
Total weight
(mm)
(kg)
600 x 745 x 220
600 x 1,045 x 220
21
29
Finned tube
Heat exchanger
Non-flammable insulation
Soundproof/Heat-insulating material
Fan
Fan unit
Standard air flow
(High/Mid./Low)
Motor
Static pressure range
Centrifugal fan
(m3/h)
(W)
460/400/300
740/600/490
19
70
(kPa)
0
Air filter
Standard filter (Simple filter)
Remote controller
Controller
Connecting
pipe
950/790/640
Gas side
(mm)
Liquid side
(mm)
O
/ 9.5
O
/ 12.7
O
/ 15.9
O
/ 6.4
Drain port (Nominal dia. mm)
O
/ 9.5
20 (One side of male screw)
36/34/32
Sound pressure level(Note 2)(High/Mid./Low) (dB(A))
42/37/33
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in
the actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
O
O
O
O
O
O
16
209
60Hz
Floor Standing Type
Model name
MMF-
Cooling/Heating capacity (Note 1)
(kW)
AP0151H
AP0181H
AP0241H
AP0271H
AP0361H
AP0481H
AP0561H
4.5/5.0
5.6/6.3
7.1/8.0
8.0/9.0
11.2/12.5
14.0/16.0
16.0/18.0
Power supply
1 phase 60Hz 220V (Separate power supply for indoor units is required.)
Running current
Electrical
characteristics
(A)
0.67
0.90
1.37
1.75
Power consumption (kW)
0.146
0.195
0.295
0.380
Power factor
Starting current
(%)
99
(A)
0.90
1.10
1.18
Height x Width x
Depth
(mm)
(kg)
Total weight
1,750 x 600 x 390
1,750 x 600 x 210
48
65
49
Heat exchanger
Finned tube
Soundproof/Heat-insulating material
Non-flammable insulation
Fan
Centrifugal fan
Fan unit
Standard air flow
(High/Mid./Low)
Motor
(m3/h)
(W)
900/780/660
1,200/1,020/840
1,680/1,920/1,380
2,160/1,860/1,560
37
63
110
160
Air filter
Standard filter (Simple filter)
Controller
Connecting
pipe
2.30
W : Silky Shade (1Y 8.5/0.5)
Appearance
Outer
dimension
99
98
Remote controller
Gas side
(mm)
O
/ 12.7
O
/ 15.9
Liquid side
(mm)
O
/ 6.4
O
/ 9.5
20 (One side of male screw)
Drain port (Nominal dia. mm)
Sound pressure level(Note 2)
(High/Mid./Low)
(dB(A))
46/43/38
49/45/40
51/48/44
54/50/46
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in
the actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
O
O
16
210
O
O
O
O
50Hz
Outdoor unit (50Hz)
Cooling Only
Model name
Heat Pump
Outdoor unit type
*
Cooling capacity ( 1)
*
Standard heating capacity ( 1)
*
Power supply ( 2)
Running current
Power consumption
Cooling Power factor
Electrical
characteristics
( 1)
*
Equivalent to
6HP
Equivalent to
5HP
Equivalent HP
EER (Energy Efficiency Ratio)
MMY-
MAP0501T8
MAP0601T8
MAP0801T8
MAP1001T8
MAP1201T8
MMY-
MAP0501HT8
MAP0601HT8
MAP1001HT8
MAP1201HT8
(kW)
14.0
16.0
MAP0801HT8
Inverter unit
22.4
28.0
33.5
(kW)
16.0
18.0
25.0
31.5
37.5
(A)
5.85
3 phase 50Hz 400V (380 - 415V)
11.55
8.62
7.28
18.30
(kW)
3.65
4.64
5.67
7.68
11.92
90
92
95
96
94
3.84
3.45
3.95
3.65
2.81
(%)
(kW/kW)
1.0
1.0
1.0
1.0
1.0
Running current
(A)
6.09
7.08
8.93
11.98
15.65
(kW)
(%)
3.84
4.56
5.88
7.97
10.19
91
4.17
93
3.95
95
4.25
96
3.95
94
3.68
1.0
1.0
1.0
1.0
Height 1,800 x Width 990 x Depth 750
1.0
Power consumption
Heating Power factor
Starting current
Total weight
(kW/kW)
(A)
(mm)
Cooling Only
(kg)
227
Heat Pump
(kg)
228
256
258
Colour
Silky shade (Munsell 1Y8.5/0.5)
Type
(kW)
Motor output
1.1 x 2
1.4 x 2
Fan
9,000
9,900
*
Connecting
method
4.2 x 2
10,500
Finned tube
*
(kg)
8.0
11
(kg)
8.5
12.5
(MPa)
OFF : 2.90
Protective devices
Connecting
port dia
3.1 x 2
0.60
(m3/h)
Cooling Only
Refrigerant R410A
(Charged refrigerant amount) ( 3) Heat Pump
High-pressure switch
Hermetic type
2.3 x 2
Propeller fan
(kW)
Motor output
Air volume
Heat exchanger
Refrigerant
piping
specifications
( 4)
Equivalent to
12HP
(A)
External dimension
Fan unit
Equivalent to
10HP
Starting current
EER (Energy Efficiency Ratio)
Compressor
Equivalent to
8HP
ON : 3.73
*
( 5)
Gas side
(mm)
Liquid side
(mm)
Balance pipe
(mm)
Gas side
O
/ 15.9
O
/ 19.1
O
/ 9.5
Flare
Brazing
Flare
Flare
Balance pipe
Max. equivalent length
(m)
Max. real length
(m)
Max. total pipe length (Real length)
(m)
Max. height difference
(m)
Control wiring
175
150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.)
300
Outdoor unit is higher than indoor unit : 50
*
Outdoor unit is lower than indoor unit : 40 ( 6)
Shield wire 1.25mm2 x 2 cores. up to 2000m
When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m
(Shield wire) 2.0mm2 x 2 cores. up to 2000m
Central remote controller
Max. No. of connected indoor units
* 1 : Rated conditions
O
/ 28.6
O
/ 12.7
Liquid side
Sound pressure level
O
/ 22.2
O
/ 9.5
(dB(A))
8
10
13
16
20
55
56
57
58
59
Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height.
+ 10%.
* 2 : The source voltage must not fluctuate more than 3
:
The
amount
does
not
consider
extra
piping
lengths.
Refrigerant must be added on site in accordance with the actual piping length.
*
4
:
The
maximum
total
piping
length
indicates
the
sum
of one-way piping lengths on the liquid side or gas side.
*
O
O
O
O
O
O
System safety protection
* 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor,
High-pressure Sensor, Low pressure sensor, Over-current relay.
6
:
* 30m when the height difference between indoor units exceeds 3m.
16
211
50Hz
Outdoor unit (Combination) (50Hz)
Equivalent HP
Equivalent to 14HP
AP1401T8
AP1401HT8
Equivalent to 16HP
Equivalent to 18HP
Equivalent to 20HP
AP1601T8
AP1801T8
AP2001T8
Set Model name
AP1601HT8
AP1801HT8
AP2001HT8
Outdoor unit type
Inverter
Cooling Only
MMY- MAP0801T8 MAP0601T8 MAP0801T8 MAP0801T8 MAP1001T8 MAP0801T8 MAP1001T8 MAP1001T8
Outdoor unit model
Heat Pump
MMY- MAP0801HT8 MAP0601HT8 MAP0801HT8 MAP0801HT8 MAP1001HT8 MAP0801HT8 MAP1001HT8 MAP1001HT8
(kW)
38.4
45
50.4
56.0
Rated cooling capacity ( 1)
43.0
50.0
56.5
63.0
(kW)
Standard heating capacity ( 1)
Power supply ( 2)
3 phase 50Hz 400V (380 - 415V)
(A)
21.29
24.31
17.08
18.54
Running current
14.16
16.17
11.12
12.20
Power consumption (kW)
(%)
96
96
Power factor
94
95
Cooling
(kW/kW)
EER
3.56
3.46
3.45
3.69
(Energy Efficiency Ratio)
Electrical
1.0
1.0
1.0
1.0
Starting current
(A)
characteristics
21.61
24.75
Running current
16.83
18.65
(A)
( 1)
14.37
16.46
10.96
12.28
Power consumption (kW)
Power factor
96
96
94
95
(%)
Heating
EER
(kW/kW)
3.93
3.83
3.92
4.07
(Energy Efficiency Ratio)
Starting current
1.0
1.0
1.0
1.0
(A)
(mm)
External dimension
Height 1,800 x Width 990 x Depth 750
(kg)
Cooling Only
256
227
256
256
256
256
256
256
Total weight
(kg)
Heat Pump
258
228
258
258
258
258
258
258
Silky shade (Munsell 1Y8.5/0.5)
Colour
Hermetic type
Type
Compressor
Motor output
3.1 x 2
2.3 x 2
2.3 x 2
1.4 x 2
2.3 x 2
3.1 x 2
(kW)
Fan
Propeller fan
(kW)
Motor output
Fan unit
0.6
(m3/h)
Air volume
10,500
9,900
9,900
9,000
9,900
10,500
Heat exchanger
Finned tube
(kg)
Cooling Only
Refrigerant R410A
11.0
8.0
11.0
11.0
11.0
11.0
11.0
11.0
Charged amount ( 3)
(kg)
Heat Pump
12.5
8.5
12.5
12.5
12.5
12.5
12.5
12.5
(MPa)
High-pressure switch
OFF : 2.90
ON : 3.73
Protective devices
( 5)
O
O
O
Gas side
/ 22.2
/ 19.1
/ 22.2
(m)
Connecting
O
O
O
(m)
Liquid side
/ 12.7
/ 9.5
/ 12.7
port dia.
(m)
Balance side
O
/ 9.5
Brazing
Gas side
Connecting
Flare
Liquid side
method
Refrigerant
Flare
Balance side
pipe spec.
( 4)
175
(m)
Max. equivalent length
Cooling Only
Heat Pump
*
*
MMYMMY-
*
*
*
*
*
Max. real length
Max. total pipe length
(Real length)
Max. height difference
(m)
(m)
Control wiring
Central remote controller
Max. No. of connected indoor units
Sound pressure level
* 1 : Rated conditions
150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.)
(m)
(dB(A))
300
Outdoor unit is higher than indoor unit : 50
Outdoor unit is lower than indoor unit : 40 ( 6)
Shield wire 1.25mm2 x 2 cores. up to 2000m
When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and
(Shield wire) 2.0mm2 x 2 cores. up to 2000m
27
30
33
23
60
60.5
61
59.5
*
Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height.
+ 10%.
* 2 : The source voltage must not fluctuate more than 3
:
The
amount
does
not
consider
extra
piping
lengths.
Refrigerant must be added on site in accordance with the actual piping length.
*
4
:
The
maximum
total
piping
length
indicates
the
sum
of one-way piping lengths on the liquid side or gas side.
*
O
O
O
System safety protection
O
O
O
* 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor,
16
212
High-pressure Sensor, Low pressure sensor, Over-current relay.
6
:
* 30m when the height difference between indoor units exceeds 3m.
50Hz
Equivalent HP
Equivalent to 22HP
Cooling Only
Heat Pump
Set Model name
MMYMMY-
AP2201T8
AP2201HT8
Outdoor unit type
MMYCooling Only
Outdoor unit model
MMYHeat Pump
(kW)
Rated cooling capacity ( 1)
(kW)
Standard heating capacity ( 1)
Power supply ( 2)
(A)
Running current
Power consumption (kW)
Power factor
(%)
Cooling
(kW/kW)
EER
(Energy Efficiency Ratio)
Electrical
Starting current
(A)
characteristics
Running current
(A)
( 1)
Power consumption (kW)
(%)
Power factor
Heating
(kW/kW)
EER
(Energy Efficiency Ratio)
(A)
Starting current
(mm)
External dimension
(kg)
Cooling Only
Total weight
Heat Pump
(kg)
Colour
Type
Compressor
Motor output
(kW)
Fan
(kW)
Motor output
Fan unit
Air volume
(m3/h)
Heat exchanger
(kg)
Cooling Only
Refrigerant R410A
Charged amount ( 3)
(kg)
Heat Pump
(MPa)
High-pressure switch
Protective devices
(mm)
Gas side
Connecting
(mm)
Liquid side
port dia.
Balance side (mm)
Gas side
Connecting
Liquid side
method
Refrigerant
Balance side
pipe spec.
Max. equivalent length
(m)
( 4)
*
*
Inverter
MAP0601T8
MAP1201T8
MAP0601HT8
MAP1201HT8
61.5
69.0
3 phase 50Hz 400V (380 - 415V)
MAP0801T8
MAP0801HT8
MAP0801T8
MAP0801HT8
*
*
Max. real length
Max. total pipe length
(Real length)
Max. height difference
(m)
95
Control wiring
Central remote controller
Max. No. of connected indoor units
Sound pressure level
* 1 : Rated conditions
3.54
3.01
1.0
26.36
17.35
1.0
28.38
18.68
95
3.98
3.69
1.0
1.0
11.0
Height 1,800 x Width 990 x Depth 750
256
227
256
258
228
258
Silky shade (Munsell 1Y8.5/0.5)
Hermetic type
1.4 x 2
4.2 x 2
Propeller fan
0.6
9,000
Finned tube
11.0
8.0
11.0
12.5
12.5
256
258
2.3 x 2
9,900
8.5
*
O
/ 22.2
O
/ 12.7
(dB(A))
256
258
3.1 x 2
10,500
11.0
12.5
OFF : 2.90
ON : 3.73
( 5)
O
/ 19.1
O
/ 9.5
O
/ 9.5
Brazing
Flare
Flare
175
12.5
O
/ 28.6
O
/ 22.2
O
/ 12.7
150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.)
300
(m)
(m)
MAP1001T8
MAP1001HT8
31.01
20.41
26.42
17.39
*
*
AP2211T8
AP2211HT8
Outdoor unit is higher than indoor unit : 50
Outdoor unit is lower than indoor unit : 40 ( 6)
Shield wire 1.25mm2 x 2 cores. up to 2000m
When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and
(Shield wire) 2.0mm2 x 2 cores. up to 2000m
37
61.5
*
Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height.
+ 10%.
* 2 : The source voltage must not fluctuate more than 3
:
The
amount
does
not
consider
extra
piping
lengths.
Refrigerant must be added on site in accordance with the actual piping length.
*
* 4 : The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side.
O
O
O
O
O
O
System safety protection
* 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor,
High-pressure Sensor, Low pressure sensor, Over-current relay.
* 6 : 30m when the height difference between indoor units exceeds 3m.
16
213
50Hz
Equivalent HP
Equivalent to 24HP
Cooling Only
Heat Pump
Set Model name
MMYMMY-
Outdoor unit type
Cooling Only
MMYOutdoor unit model
Heat Pump
MMYRated cooling capacity ( 1)
(kW)
Standard heating capacity ( 1)
(kW)
Power supply ( 2)
(A)
Running current
Power consumption (kW)
Cooling Power factor
(%)
(kW/kW)
EER
(Energy Efficiency Ratio)
Electrical
Starting current
(A)
characteristics
Running current
(A)
( 1)
Power consumption (kW)
Heating Power factor
(%)
(kW/kW)
EER
(Energy Efficiency Ratio)
(A)
Starting current
(mm)
External dimension
(kg)
Cooling Only
Total weight
(kg)
Heat Pump
Colour
Type
Compressor
(kW)
Motor output
Fan
(kW)
Motor output
Fan unit
Air volume
(m3/h)
Heat exchanger
(kg)
Cooling Only
Refrigerant R410A
Charged amount ( 3)
Heat Pump
(kg)
High-pressure switch
(MPa)
Protective devices
Gas side
(mm)
Connecting Liquid side
(mm)
port dia.
Balance side (mm)
Gas side
Connecting
Liquid side
method
Refrigerant
Balance side
pipe spec.
Max. equivalent length
(m)
( 4)
Max. real length
(m)
Max. total pipe length
(m)
(Real length)
*
*
Inverter
MAP0801T8
MAP1201T8
MAP0801HT8
MAP1201HT8
68.0
76.5
3 phase 50Hz 400V (380 - 415V)
MAP0801T8
MAP0801HT8
MAP0801T8
MAP0801HT8
*
*
*
*
Max. height difference
(m)
Control wiring
Central remote controller
Max. No. of connected indoor units
Sound pressure level
* 1 : Rated conditions
AP2411T8
AP2411HT8
AP2401T8
AP2401HT8
27.73
18.44
96
38.02
25.02
95
3.69
2.72
1.0
27.96
18.79
97
1.0
32.06
21.32
96
4.07
3.59
1.0
1.0
Height 1,800 x Width 990 x Depth 750
256
256
256
258
258
258
Silky shade (Munsell 1Y8.5/0.5)
Hermetic type
2.3 x 2
Propeller fan
0.6
9,900
Finned tube
11.0
11.0
11.0
12.5
12.5
12.5
OFF : 2.90
ON : 3.73
( 5)
O
/ 22.2
O
/ 12.7
O
/ 9.5
Brazing
Flare
Flare
175
256
258
11.0
12.5
MAP1201T8
MAP1201HT8
*
256
258
4.2 x 2
10,500
11.0
12.5
O
/ 28.6
150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.)
300
Outdoor unit is higher than indoor unit : 50
Outdoor unit is lower than indoor unit : 40 ( 6)
Shield wire 1.25mm2 x 2 cores. up to 2000m
When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and
(Shield wire) 2.0mm2 x 2 cores. up to 2000m
*
40
62
(dB(A))
Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height.
+ 10%.
* 2 : The source voltage must not fluctuate more than 3
:
The
amount
does
not
consider
extra
piping
lengths.
Refrigerant must be added on site in accordance with the actual piping length.
*
* 4 : The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side.
O
O
O
System safety protection
O
O
O
* 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor,
16
214
High-pressure Sensor, Low pressure sensor, Over-current relay.
* 6 : 30m when the height difference between indoor units exceeds 3m.
50Hz
Equivalent to 26HP
Equivalent HP
Cooling Only
Heat Pump
MMYMMY-
AP2601T8
AP2601HT8
(A)
(mm)
(kg)
(kg)
1.0
Equivalent to 28HP
Equivalent to 30HP
AP2801T8
AP3001T8
Set Model name
AP2801HT8
AP3001HT8
Outdoor unit type
Inverter
Cooling Only
MMY- MAP1001T8 MAP0801T8 MAP0801T8 MAP1001T8 MAP1001T8 MAP0801T8 MAP1001T8 MAP1001T8 MAP1001T8
Outdoor unit model
Heat Pump
MMY- MAP1001HT8 MAP0801HT8 MAP0801HT8 MAP1001HT8 MAP1001HT8 MAP0801HT8 MAP1001HT8 MAP1001HT8 MAP1001HT8
(kW)
78.5
84.0
73
Rated cooling capacity ( 1)
(kW)
Standard heating capacity ( 1)
88.0
95.0
81.5
3 phase 50Hz 400V (380 - 415V)
Power supply ( 2)
(A)
33.48
36.48
30.51
Running current
22.27
24.26
Power consumption (kW)
20.29
(%)
Power factor
96
Cooling
(kW/kW)
EER
3.52
3.46
3.60
(Energy Efficiency Ratio)
Electrical
(A)
1.0
1.0
1.0
Starting current
characteristics
(A)
Running current
33.98
36.93
31.16
( 1)
Power consumption (kW)
22.60
24.82
20.51
(%)
96
97
95
Heating Power factor
(kW/kW)
EER
3.89
3.83
3.97
(Energy Efficiency Ratio)
*
*
*
*
Starting current
External dimension
Cooling Only
Heat Pump
Total weight
256
258
256
258
256
258
Colour
Type
Motor output
Fan
Motor output
Fan unit
Air volume
Heat exchanger
Cooling Only
Refrigerant R410A
Charged amount ( 3)
Heat Pump
High-pressure switch
Protective devices
Gas side
Connecting
Liquid side
port dia.
Balance side
Gas side
Connecting
Liquid side
method
Refrigerant
Balance side
pipe spec.
( 4)
Max. equivalent length
Compressor
*
*
Max. real length
Max. total pipe length
(Real length)
Max. height difference
(kW)
(kW)
(m3/h)
(kg)
(kg)
(MPa)
11.0
12.5
9,900
11.0
12.5
11.0
12.5
1.0
256
258
256
258
256
258
3.1 x 2
10,500
11.0
12.5
11.0
12.5
11.0
12.5
*
(m)
175
(m)
150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.)
(m)
300
(m)
Outdoor unit is higher than indoor unit : 50
Outdoor unit is lower than indoor unit : 40 ( 6)
Shield wire 1.25mm2 x 2 cores. up to 2000m
When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and
(Shield wire) 2.0mm2 x 2 cores. up to 2000m
47
48
43
62.5
63
62
Central remote controller
* 1 : Rated conditions
10,500
(mm)
(mm)
(mm)
Control wiring
Max. No. of connected indoor units
Sound pressure level
2.3 x 2
1.0
Height 1,800 x Width 990 x Depth 750
256
256
256
258
258
258
Silky shade (Munsell 1Y8.5/0.5)
Hermetic type
3.1 x 2
2.3 x 2
Propeller fan
0.6
9,900
10,500
Finned tube
11.0
11.0
11.0
12.5
12.5
12.5
OFF : 2.90
ON : 3.73
( 5)
O
/ 22.2
O
/ 12.7
O
/ 9.5
Brazing
Flare
Flare
(dB(A))
*
Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height.
+ 10%.
* 2 : The source voltage must not fluctuate more than 3
:
The
amount
does
not
consider
extra
piping
lengths.
Refrigerant must be added on site in accordance with the actual piping length.
*
* 4 : The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side.
O
O
O
O
O
O
System safety protection
* 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor,
High-pressure Sensor, Low pressure sensor, Over-current relay.
* 6 : 30m when the height difference between indoor units exceeds 3m.
16
215
50Hz
Equivalent to 32HP
Equivalent HP
Cooling Only
Heat Pump
Set Model name
MMYMMY-
AP3201T8
AP3201HT8
Outdoor unit type
Cooling Only
MMYOutdoor unit model
Heat Pump
MMYRated cooling capacity ( 1)
(kW)
Standard heating capacity ( 1)
(kW)
Power supply ( 2)
Running current
(A)
Power consumption (kW)
Power factor
(%)
Cooling
EER
(kW/kW)
(Energy Efficiency Ratio)
Electrical
Starting current
(A)
characteristics
Running current
(A)
( 1)
Power consumption (kW)
(%)
Power factor
Heating
EER
(kW/kW)
(Energy Efficiency Ratio)
Starting current
(A)
(mm)
External dimension
Cooling Only
(kg)
Total weight
(kg)
Heat Pump
Colour
Type
Compressor
(kW)
Motor output
*
*
MAP0801T8 MAP0801T8
MAP0801HT8 MAP0801HT8
Fan
Fan unit
Motor output
Air volume
Heat exchanger
Cooling Only
Refrigerant R410A
Charged amount ( 3)
Heat Pump
High-pressure switch
Protective devices
Gas side
Connecting
Liquid side
port dia.
Balance side
Gas side
Connecting
Liquid side
method
Refrigerant
Balance side
pipe spec.
( 4)
Max. equivalent length
*
*
Inverter
MAP0801T8 MAP1201T8
MAP0801HT8 MAP1201HT8
90.0
100.0
3 phase 50Hz 400V (380 - 415V)
MAP0801T8
MAP0801HT8
*
*
Max. real length
Max. total pipe length
(Real length)
Max. height difference
(kg)
(kg)
(MPa)
11.0
12.5
MAP1001T8 MAP1001T8
MAP1001HT8 MAP1001HT8
37.09
24.41
95
43.08
28.65
96
3.69
3.14
1.0
37.32
24.56
95
1.0
40.69
26.78
95
4.07
3.73
1.0
1.0
Height 1,800 x Width 990 x Depth 750
256
256
256
258
258
258
Silky shade (Munsell 1Y8.5/0.5)
Hermetic type
2.3 x 2
4.2 x 2
Propeller fan
0.6
9,900
Finned tube
11.0
12.5
11.0
12.5
O
/ 22.2
(mm)
(mm)
(mm)
256
258
256
258
3.1 x 2
10,500
11.0
11.0
12.5
12.5
OFF : 2.90
ON : 3.73
( 5)
O
/ 28.6
O
/ 12.7
O
/ 9.5
Brazing
Flare
Flare
11.0
12.5
*
11.0
12.5
O
/ 22.2
(m)
175
(m)
150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.)
(m)
(m)
Central remote controller
* 1 : Rated conditions
256
258
(kW)
(m3/h)
Control wiring
Max. No. of connected indoor units
Sound pressure level
256
258
AP3211T8
AP3211HT8
(dB(A))
300
Outdoor unit is higher than indoor unit : 50
Outdoor unit is lower than indoor unit : 40 ( 6)
Shield wire 1.25mm2 x 2 cores. up to 2000m
When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and
(Shield wire) 2.0mm2 x 2 cores. up to 2000m
48
63
*
Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height.
+ 10%.
* 2 : The source voltage must not fluctuate more than 3
:
The
amount
does
not
consider
extra
piping
lengths.
Refrigerant must be added on site in accordance with the actual piping length.
*
4
:
The
maximum
total
piping
length
indicates
the
sum
of one-way piping lengths on the liquid side or gas side.
*
O
O
O
System safety protection
O
O
O
* 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor,
16
216
High-pressure Sensor, Low pressure sensor, Over-current relay.
6
:
* 30m when the height difference between indoor units exceeds 3m.
50Hz
Equivalent to 34HP
Equivalent HP
Cooling Only
Heat Pump
Set Model name
MMYMMY-
AP3411T8
AP3411HT8
AP3401T8
AP3401HT8
Inverter
Outdoor unit type
Cooling Only
MMY- MAP1001T8
Outdoor unit model
Heat Pump
MMY- MAP1001HT8
(kW)
Rated cooling capacity ( 1)
Standard heating capacity ( 1)
(kW)
Power supply ( 2)
(A)
Running current
Power consumption (kW)
(%)
Power factor
Cooling
(kW/kW)
EER
(Energy Efficiency Ratio)
Electrical
(A)
Starting current
characteristics
(A)
Running current
( 1)
Power consumption (kW)
(%)
Power factor
Heating
(kW/kW)
EER
(Energy Efficiency Ratio)
Starting current
(A)
(mm)
External dimension
(kg)
256
Cooling Only
Total weight
(kg)
Heat Pump
258
Colour
Type
Compressor
(kW)
3.1 x 2
Motor output
Fan
(kW)
Motor output
Fan unit
Air volume
(m3/h)
10,500
Heat exchanger
11.0
Refrigerant R410A
(kg)
Cooling Only
Charged amount ( 3)
Heat Pump
12.5
(kg)
(MPa)
High-pressure switch
Protective devices
Gas side
(mm)
Connecting Liquid side
(mm)
port dia.
Balance side (mm)
Gas side
Connecting
Liquid side
Refrigerant method
Balance side
pipe spec.
( 4)
(m)
Max. equivalent length
*
*
MAP0801T8
MAP0801HT8
MAP0801T8
MAP0801HT8
MAP0801T8 MAP1201T8
MAP0801HT8 MAP1201HT8
96.0
108.0
3 phase 50Hz 400V (380 - 415V)
*
*
*
*
Max. real length
Max. total pipe length
(Real length)
Max. height difference
(m)
Control wiring
Central remote controller
Max. No. of connected indoor units
Sound pressure level
* 1 : Rated conditions
39.89
26.53
96
50.26
33.08
95
3.62
2.90
1.0
40.22
27.03
97
1.0
44.42
29.54
96
4.00
3.66
1.0
Height 1,800 x Width 990 x Depth 750
256
256
256
256
256
258
258
258
258
258
Silky shade (Munsell 1Y8.5/0.5)
Hermetic type
2.3 x 2
4.2 x 2
Propeller fan
0.6
9,900
10,500
Finned tube
11.0
11.0
11.0
11.0
11.0
12.5
12.5
12.5
12.5
12.5
OFF : 2.90
ON : 3.73
( 5)
O
O
/ 22.2
/ 28.6
O
/ 12.7
O
/ 9.5
Brazing
Flare
Flare
175
1.0
*
(dB(A))
256
258
3.1 x 2
11.0
12.5
O
/ 22.2
150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.)
(m)
(m)
MAP1201T8 MAP1001T8
MAP1201HT8 MAP1001HT8
300
Outdoor unit is higher than indoor unit : 50
Outdoor unit is lower than indoor unit : 40 ( 6)
Shield wire 1.25mm2 x 2 cores. up to 2000m
When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and
(Shield wire) 2.0mm2 x 2 cores. up to 2000m
48
63.5
63.5
*
Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height.
+ 10%.
* 2 : The source voltage must not fluctuate more than 3
:
The
amount
does
not
consider
extra
piping
lengths.
Refrigerant must be added on site in accordance with the actual piping length.
*
* 4 : The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side.
O
O
O
O
O
O
System safety protection
* 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor,
High-pressure Sensor, Low pressure sensor, Over-current relay.
* 6 : 30m when the height difference between indoor units exceeds 3m.
16
217
50Hz
Equivalent HP
Equivalent to 36HP
Cooling Only
Heat Pump
Set Model name
AP3601T8
AP3601HT8
MMYMMY-
AP3611T8
AP3611HT8
Inverter
Cooling Only
MMY- MAP1001T8 MAP1001T8 MAP0801T8 MAP0801T8 MAP1201T8
Outdoor unit model
Heat Pump
MMY- MAP1001HT8 MAP1001HT8 MAP0801HT8 MAP0801HT8 MAP1201HT8
(kW)
101.0
Rated cooling capacity ( 1)
(kW)
Standard heating capacity ( 1)
113.0
3 phase 50Hz 400V (380 - 415V)
Power supply ( 2)
42.67
(A)
Running current
Power consumption (kW)
28.38
(%)
Power factor
96
Cooling
EER
(kW/kW)
3.56
(Energy Efficiency Ratio)
Electrical
(A)
Starting current
1.0
characteristics
( 1)
(A)
Running current
43.21
Power consumption (kW)
28.74
(%)
96
Heating Power factor
EER
(kW/kW)
3.93
(Energy Efficiency Ratio)
(A)
Starting current
1.0
(mm)
External dimension
Height 1,800 x Width 990 x Depth 750
Cooling Only
(kg)
256
256
256
256
256
Total weight
Heat Pump
(kg)
258
258
258
258
258
Colour
Silky shade (Munsell 1Y8.5/0.5)
Type
Hermetic type
Compressor
(kW)
2.3 x 2
Motor output
3.1 x 2
Propeller fan
Fan
Motor output
0.6
(kW)
Fan unit
(m3/h)
9,900
Air volume
10,500
Finned tube
Heat exchanger
Outdoor unit type
*
*
MAP1201T8 MAP1201T8
MAP1201HT8 MAP1201HT8
*
57.06
37.16
94
2.72
1.0
48.36
31.49
94
*
Cooling Only
Heat Pump
(kg)
(kg)
(MPa)
Gas side
Connecting Liquid side
port dia.
Balance side
Gas side
Connecting Liquid side
method
Balance side
(mm)
(mm)
(mm)
Refrigerant R410A
Charged amount ( 3)
High-pressure switch
Protective devices
*
Refrigerant
pipe spec.
( 4)
*
11.0
12.5
11.0
12.5
11.0
12.5
O
/ 22.2
3.59
1.0
256
258
256
258
4.2 x 2
10,500
11.0
11.0
12.5
12.5
OFF : 2.90
ON : 3.73
( 5)
11.0
12.5
*
11.0
12.5
O
/ 28.6
O
/ 12.7
Max. equivalent length
(m)
O
/ 9.5
Brazing
Flare
Flare
175
Max. real length
Max. total pipe length
(Real length)
(m)
150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.)
Max. height difference
(m)
(m)
Control wiring
Central remote controller
Max. No. of connected indoor units
Sound pressure level
* 1 : Rated conditions
(dB(A))
300
Outdoor unit is higher than indoor unit : 50
Outdoor unit is lower than indoor unit : 40 ( 6)
Shield wire 1.25mm2 x 2 cores. up to 2000m
When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and
(Shield wire) 2.0mm2 x 2 cores. up to 2000m
48
63.5
64
*
Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height.
+ 10%.
* 2 : The source voltage must not fluctuate more than 3
:
The
amount
does
not
consider
extra
piping
lengths.
Refrigerant must be added on site in accordance with the actual piping length.
*
* 4 : The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side.
O
O
O
System safety protection
O
O
O
* 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor,
16
218
High-pressure Sensor, Low pressure sensor, Over-current relay.
* 6 : 30m when the height difference between indoor units exceeds 3m.
50Hz
Equivalent HP
Cooling Only
Heat Pump
Set Model name
MMYMMY-
Equivalent to 38HP
Equivalent to 40HP
AP3801T8
AP3801HT8
AP4001T8
AP4001HT8
Outdoor unit type
Inverter
Cooling Only
MMY- MAP1001T8 MAP1001T8 MAP1001T8 MAP0801T8 MAP1001T8 MAP1001T8 MAP1001T8 MAP1001T8
Outdoor unit model
Heat Pump
MMY- MAP1001HT8 MAP1001HT8 MAP1001HT8 MAP0801HT8 MAP1001HT8 MAP1001HT8 MAP1001HT8 MAP1001HT8
(kW)
Rated cooling capacity ( 1)
112.0
106.5
Standard heating capacity ( 1)
(kW)
126.5
119.5
Power supply ( 2)
3 phase 50Hz 400V (380 - 415V)
(A)
Running current
48.63
45.65
32.34
Power consumption (kW)
30.36
Power factor
96
(%)
Cooling
EER
(kW/kW)
3.46
3.51
(Energy Efficiency Ratio)
Electrical
Starting current
(A)
1.0
1.0
characteristics
(A)
Running current
49.69
46.36
( 1)
Power consumption (kW)
33.05
30.83
(%)
96
Heating Power factor
(kW/kW)
EER
3.83
3.88
(Energy Efficiency Ratio)
(A)
1.0
Starting current
1.0
(mm)
External dimension
Height 1,800 x Width 990 x Depth 750
(kg)
Cooling Only
256
256
256
256
256
256
256
256
Total weight
(kg)
Heat Pump
258
258
258
258
258
258
258
258
Colour
Silky shade (Munsell 1Y8.5/0.5)
Type
Hermetic type
Compressor
(kW)
Motor output
3.1 x 2
2.3 x 2
3.1 x 2
Fan
Propeller fan
Fan unit
Motor output
(kW)
0.6
10,500
9,900
10,500
(m3/h)
Air volume
Finned tube
Heat exchanger
(kg)
Cooling Only
11.0
11.0
11.0
11.0
11.0
11.0
11.0
11.0
Refrigerant R410A
(kg)
Charged amount ( 3)
Heat Pump
12.5
12.5
12.5
12.5
12.5
12.5
12.5
12.5
High-pressure switch
(MPa)
OFF : 2.90
ON : 3.73
( 5)
Protective devices
Gas side
(mm)
O
/ 22.2
Connecting Liquid side
O
/ 12.7
(mm)
port dia.
Balance side (mm)
O
/ 9.5
Gas side
Brazing
Connecting Liquid side
Flare
method
Flare
Balance side
Refrigerant
pipe spec.
(m)
175
Max. equivalent length
( 4)
150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.)
(m)
Max. real length
Max. total pipe length
(m)
300
(Real length)
Outdoor unit is higher than indoor unit : 50
(m)
Max. height difference
Outdoor unit is lower than indoor unit : 40 ( 6)
Control wiring
Shield wire 1.25mm2 x 2 cores. up to 2000m
When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and
Central remote controller
(Shield wire) 2.0mm2 x 2 cores. up to 2000m
Max. No. of connected indoor units
48
(dB(A))
64
Sound pressure level
*
*
*
*
*
*
*
*
* 1 : Rated conditions
Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height.
+ 10%.
* 2 : The source voltage must not fluctuate more than 3
:
The
amount
does
not
consider
extra
piping
lengths.
Refrigerant must be added on site in accordance with the actual piping length.
*
* 4 : The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side.
O
O
O
O
O
O
System safety protection
* 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor,
High-pressure Sensor, Low pressure sensor, Over-current relay.
* 6 : 30m when the height difference between indoor units exceeds 3m.
16
219
50Hz
Equivalent to 42HP
AP4201T8
AP4201HT8
Equivalent HP
Cooling Only
Heat Pump
Set Model name
MMYMMY-
Outdoor unit type
Cooling Only
MMYOutdoor unit model
Heat Pump
MMY(kW)
Rated cooling capacity ( 1)
(kW)
Standard heating capacity ( 1)
Power supply ( 2)
(A)
Running current
Power consumption (kW)
(%)
Power factor
Cooling
EER
(kW/kW)
(Energy Efficiency Ratio)
Electrical
Starting current
(A)
characteristics
( 1)
Running current
(A)
Power consumption (kW)
(%)
Heating Power factor
EER
(kW/kW)
(Energy Efficiency Ratio)
(A)
Starting current
(mm)
External dimension
(kg)
Cooling Only
Total weight
(kg)
Heat Pump
Colour
Type
Compressor
(kW)
Motor output
Fan
Fan unit
(kW)
Motor output
(m3/h)
Air volume
Heat exchanger
(kg)
Cooling Only
Refrigerant R410A
Charged amount ( 3)
(kg)
Heat Pump
(MPa)
High-pressure switch
Protective devices
Gas side
(mm)
Connecting Liquid side
(mm)
port dia.
Balance side (mm)
Gas side
Connecting Liquid side
method
Balance side
Refrigerant
pipe spec.
Max. equivalent length
(m)
( 4)
Max. real length
(m)
Max. total pipe length
(m)
(Real length)
*
*
*
Inverter
MAP1201T8 MAP1001T8 MAP1001T8 MAP1001T8 MAP1201T8 MAP1201T8 MAP1001T8 MAP1001T8
MAP1201HT8 MAP1001HT8 MAP1001HT8 MAP1001HT8 MAP1201HT8 MAP1201HT8 MAP1001HT8 MAP1001HT8
123.5
118.0
138.5
132.0
3 phase 50Hz 400V (380 - 415V)
55.24
62.28
36.74
40.99
96
95
*
*
*
Max. height difference
(m)
Control wiring
Central remote controller
Max. No. of connected indoor units
Sound pressure level
* 1 : Rated conditions
(dB(A))
Equivalent to 44HP
AP4401T8
AP4401HT8
3.21
3.01
1.0
5.39
35.14
1.0
56.76
37.36
95
3.76
3.69
1.0
256
258
256
258
4.2 x 2
11.0
12.5
11.0
12.5
1.0
Height 1,800 x Width 990 x Depth 750
256
256
256
256
258
258
258
258
Silky shade (Munsell 1Y8.5/0.5)
Hermetic type
3.1 x 2
4.2 x 2
11.0
12.5
O
/ 22.2
O
/ 28.6
256
258
256
258
3.1 x 2
Propeller fan
0.6
10,500
Finned tube
11.0
11.0
11.0
12.5
12.5
12.5
OFF : 2.90
ON : 3.73
( 5)
O
/ 28.6
O
/ 12.7
O
/ 9.5
Brazing
Flare
Flare
175
11.0
12.5
*
11.0
12.5
O
/ 22.2
150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.)
300
Outdoor unit is higher than indoor unit : 50
Outdoor unit is lower than indoor unit : 40 ( 6)
Shield wire 1.25mm2 x 2 cores. up to 2000m
When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and
(Shield wire) 2.0mm2 x 2 cores. up to 2000m
48
64.5
*
Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height.
+ 10%.
* 2 : The source voltage must not fluctuate more than 3
:
The
amount
does
not
consider
extra
piping
lengths.
Refrigerant must be added on site in accordance with the actual piping length.
*
* 4 : The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side.
O
O
O
System safety protection
O
O
O
* 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor,
16
220
High-pressure Sensor, Low pressure sensor, Over-current relay.
* 6 : 30m when the height difference between indoor units exceeds 3m.
50Hz
Equivalent HP
Cooling Only
Heat Pump
Set Model name
MMYMMY-
Equivalent to 46HP
AP4601T8
AP4601HT8
Equivalent to 48HP
AP4801T8
AP4801HT8
Outdoor unit type
Inverter
Cooling Only
MMY- MAP1201T8 MAP1201T8 MAP1201T8 MAP1001T8 MAP1201T8 MAP1201T8 MAP1201T8 MAP1201T8
Heat Pump
MMY- MAP1201HT8 MAP1201HT8 MAP1201HT8 MAP1001HT8 MAP1201HT8 MAP1201HT8 MAP1201HT8 MAP1201HT8
(kW)
Rated cooling capacity ( 1)
135.0
130.0
Standard heating capacity ( 1)
(kW)
150.0
145.0
3 phase 50Hz 400V (380 - 415V)
Power supply ( 2)
75.47
Running current
(A)
69.27
49.67
45.59
Power consumption (kW)
Power factor
95
(%)
Cooling
EER
(kW/kW)
2.72
2.85
(Energy Efficiency Ratio)
Electrical
Starting current
(A)
1.0
1.0
characteristics
(A)
64.19
Running current
60.55
( 1)
Power consumption (kW)
41.80
39.85
(%)
94
95
Heating Power factor
(kW/kW)
EER
3.59
3.64
(Energy Efficiency Ratio)
(A)
Starting current
1.0
1.0
(mm)
Height 1,800 x Width 990 x Depth 750
External dimension
(kg)
256
256
256
256
256
256
256
256
Cooling Only
Total weight
Heat Pump
(kg)
258
258
258
258
258
258
258
258
Silky shade (Munsell 1Y8.5/0.5)
Colour
Type
Hermetic type
Compressor
(kW)
3.1 x 2
4.2 x 2
4.2 x 2
Motor output
Fan
Propeller fan
Fan unit
Motor output
0.6
(kW)
10,500
(m3/h)
Air volume
Finned tube
Heat exchanger
(kg)
Cooling Only
11.0
11.0
11.0
11.0
11.0
11.0
11.0
11.0
Refrigerant R410A
(kg)
Charged amount ( 3)
Heat Pump
12.5
12.5
12.5
12.5
12.5
12.5
12.5
12.5
(MPa)
High-pressure switch
OFF : 2.90
ON : 3.73
( 5)
Protective devices
Gas side
(mm)
O
O
O
/ 28.6
/ 22.2
/ 28.6
Connecting Liquid side
O
/ 12.7
(mm)
port dia.
Balance side (mm)
O
/ 9.5
Brazing
Gas side
Connecting Liquid side
Flare
method
Balance side
Flare
Refrigerant
pipe spec.
(m)
160
Max. equivalent length
( 4)
135 (If the total bend length exceeds 135m, use the max equivalent length as the standard.)
Max. real length
(m)
Outdoor unit model
*
*
*
*
*
*
*
Max. total pipe length
(Real length)
Max. height difference
(m)
Control wiring
Central remote controller
Max. No. of connected indoor units
Sound pressure level
* 1 : Rated conditions
300
(m)
(dB(A))
Outdoor unit is higher than indoor unit : 50
Outdoor unit is lower than indoor unit : 40 ( 6)
Shield wire 1.25mm2 x 2 cores. up to 2000m
When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and
(Shield wire) 2.0mm2 x 2 cores. up to 2000m
48
65
*
Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height.
+ 10%.
* 2 : The source voltage must not fluctuate more than 3
:
The
amount
does
not
consider
extra
piping
lengths.
Refrigerant must be added on site in accordance with the actual piping length.
*
* 4 : The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side.
O
O
O
O
O
O
System safety protection
* 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor,
High-pressure Sensor, Low pressure sensor, Over-current relay.
* 6 : 30m when the height difference between indoor units exceeds 3m.
16
221
60Hz
Outdoor unit (60Hz)
Equivalent HP
Model name
MMY-
Heat Pump
Equivalent to
5HP
Equivalent to
6HP
Equivalent to
8HP
Equivalent to
10HP
Equivalent to
12HP
MAP0501HT7
MAP0601HT7
MAP0801HT7
MAP1001HT7
MAP1201HT7
Inverter unit
Outdoor unit type
*
Cooling capacity ( 1)
*
Standard heating capacity ( 1)
*
Power supply ( 2)
Running current
16.0
22.4
28.0
33.5
16.0
18.0
25.0
31.5
37.5
(A)
6.16
7.66
9.07
12.16
19.27
(kW)
3.65
4.64
5.67
7.68
11.92
(%)
90
92
95
96
94
EER (Energy Efficiency Ratio) (kW/kW)
3.84
3.45
3.95
3.65
2.81
Starting current
(A)
1.0
1.0
1.0
1.0
1.0
Cooling Power factor
*
14.0
(kW)
3 phase 60Hz 380V
Power consumption
Electrical
characteristics
( 1)
(kW)
Running current
(A)
6.41
7.45
9.40
12.61
16.47
(kW)
3.84
4.56
5.88
7.97
10.19
(%)
91
93
95
96
94
EER (Energy Efficiency Ratio) (kW/kW)
4.17
3.95
4.25
3.95
3.68
(A)
1.0
1.0
1.0
1.0
1.0
Power consumption
Heating Power factor
Starting current
(mm)
External dimension
Height 1,800 x Width 990 x Depth 750
(kg)
Total weight
228
258
Silky shade (Munsell 1Y8.5/0.5)
Colour
Compressor
Hermetic type
Type
(kW)
Motor output
1.1 x 2
1.4 x 2
Fan unit
Motor output
9,000
9,900
Heat exchanger
*
High-pressure switch
(kg)
R410A (8.5)
ON : 3.73
*
( 5)
Gas side
(mm)
Liquid side
(mm)
Balance pipe
(mm)
Gas side
*
10,500
R410A (12.5)
OFF : 2.90
(MPa)
Protective devices
Refrigerant
piping
specifications
( 4)
4.2 x 2
Finned tube
Refrigerant R410A(Charged refrigerant amount) ( 3)
Connecting
method
3.1 x 2
0.60
(kW)
(m3/h)
Air volume
Connecting
port dia
2.3 x 2
Propeller fan
Fan
O
/ 15.9
O
/ 19.1
O
/ 22.2
O
/ 9.5
O
/ 28.6
O
/ 12.7
O
/ 9.5
Flare
Brazing
Flare
Liquid side
Flare
Balance pipe
Max. equivalent length
(m)
175
Max. real length
(m)
150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.)
Max. total pipe length (Real length)
(m)
Max. height difference
300
Outdoor unit is higher than indoor unit : 50
(m)
*
Outdoor unit is lower than indoor unit : 40 ( 6)
Shield wire 1.25mm2 x 2 cores. up to 2000m
Control wiring
When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and
(Shield wire) 2.0mm2 x 2 cores. up to 2000m
Central remote controller
Max. No. of connected indoor units
Sound pressure level
* 1 : Rated conditions
(dB(A))
8
10
13
16
20
55
56
57
58
59
Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height.
+ 10%.
* 2 : The source voltage must not fluctuate more than 3
:
The
amount
does
not
consider
extra
piping
lengths.
Refrigerant must be added on site in accordance with the actual piping length.
*
4
:
The
maximum
total
piping
length
indicates
the
sum
of one-way piping lengths on the liquid side or gas side.
*
O
O
O
System safety protection
16
222
O
O
O
* 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor,
High-pressure Sensor, Low pressure sensor, Over-current relay.
6
:
* 30m when the height difference between indoor units exceeds 3m.
60Hz
Outdoor unit (Combination) (60Hz)
Equivalent HP
Set Model name
Outdoor unit type
Outdoor unit type
Heat Pump
MMY-
Equivalent to 14HP
Equivalent to 16HP
Equivalent to 18HP
Equivalent to 20HP
AP1401HT7
AP1601HT7
AP1801HT7
AP2001HT7
Inverter
Heat Pump
*
MMY- MAP0801HT7 MAP0601HT7 MAP0801HT7 MAP0801HT7 MAP1001HT7 MAP0801HT7 MAP1001HT7 MAP1001HT7
(kW)
38.4
45
50.4
56.0
Rated cooling capacity ( 1)
*
(kW)
Standard heating capacity ( 1)
Power supply ( 2)
(A)
Running current
Power consumption (kW)
Power factor
(%)
Cooling EER
(kW/kW)
(Energy Efficiency Ratio)
Electrical
(A)
Starting current
characteristics
(A)
Running current
( 1)
*
*
43.0
(%)
Power factor
(kW/kW)
EER
(Energy Efficiency Ratio)
Starting current
Compressor
Type
Motor output
(A)
19.51
12.20
22.41
14.16
25.59
16.17
94
95
96
96
3.45
3.69
3.56
3.46
1.0
17.72
1.0
19.64
1.0
22.74
1.0
26.05
10.96
94
12.28
95
14.37
96
16.46
96
3.92
4.07
3.93
3.83
1.0
1.0
1.0
1.0
Height 1,800 x Width 990 x Depth 750
(kg)
258
228
(kW)
2.3 x 2
1.4 x 2
258
258
258
258
Silky shade (Munsell 1Y8.5/0.5)
Hermetic type
2.3 x 2
3.1 x 2
2.3 x 2
Fan
(kW)
Motor output
(m3/h)
Air volume
Heat exchanger
Refrigerant R410A Charged amount ( 3) (kg)
High-pressure switch
(MPa)
*
258
3.1 x 2
0.6
9,900
9,000
12.5
8.5
9,900
10,500
Finned tube
9,900
10,5000
12.5
OFF : 2.90
ON : 3.73
*
( 5)
Protective devices
Gas side
*
258
Propeller fan
Fan unit
Refrigerant
pipe spec.
( 4)
63.0
17.97
11.12
(mm)
External dimension
Total weight
Colour
56.5
3 phase 60Hz 380V
Power consumption (kW)
Heating
50.0
Connecting
Liquid side
port dia.
Balance side
Gas side
Connecting
Liquid side
method
Balance side
(mm)
O
/ 22.2
O
/ 19.1
(mm)
O
/ 12.7
O
/ 9.5
O
/ 22.2
O
/ 12.7
(mm)
O
/ 9.5
Brazing
Flare
Flare
Max. equivalent length
(m)
175
Max. real length
Max. total pipe length
(Real length)
(m)
150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.)
Max. height difference
(m)
(m)
Control wiring
Central remote controller
Max. No. of connected indoor units
Sound pressure level
* 1 : Rated conditions
(dB(A))
300
Outdoor unit is higher than indoor unit : 50
*
Outdoor unit is lower than indoor unit : 40 ( 6)
Shield wire 1.25mm2 x 2 cores. up to 2000m
When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and
(Shield wire) 2.0mm2 x 2 cores. up to 2000m
23
27
30
33
59.5
60
60.5
61
Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height.
+ 10%.
* 2 : The source voltage must not fluctuate more than 3
:
The
amount
does
not
consider
extra
piping
lengths.
Refrigerant must be added on site in accordance with the actual piping length.
*
4
:
The
maximum
total
piping
length
indicates
the
sum
of one-way piping lengths on the liquid side or gas side.
*
O
O
O
O
O
O
System safety protection
* 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor,
High-pressure Sensor, Low pressure sensor, Over-current relay.
6
:
* 30m when the height difference between indoor units exceeds 3m.
16
223
60Hz
Equivalent HP
Equivalent to 22HP
Set Model name
Outdoor unit type
Outdoor unit model
Heat Pump
MMY-
Inverter
MMY(kW)
Heat Pump
*
Rated cooling capacity ( 1)
Standard heating capacity ( 1)
*
Power supply ( 2)
Electrical
characteristics
( 1)
*
*
MAP1001HT7
3.54
3.01
1.0
27.75
17.35
1.0
29.88
18.68
95
3.98
3.69
1.0
1.0
Height 1,800 x Width 990 x Depth 750
258
258
228
Silky shade (Munsell 1Y8.5/0.5)
Type
Motor output
Fan
(kW)
2.3 x 2
Motor output
Air volume
(kW)
(m3/h)
9,900
*
20.41
95
(A)
(mm)
(kg)
32.64
17.39
(A)
Starting current
(A)
Running current
Power consumption (kW)
(%)
Power factor
Heating
EER
(kW/kW)
(Energy Efficiency Ratio)
Heat exchanger
Refrigerant R410A Charged amount ( 3) (kg)
(MPa)
High-pressure switch
Protective devices
(mm)
Gas side
Connecting
(mm)
Liquid side
port dia.
Balance side (mm)
*
MAP1201HT7
27.81
Power factor
(%)
Cooling
(kW/kW)
EER
(Energy Efficiency Ratio)
Total weight
Colour
Refrigerant
pipe spec.
( 4)
MAP0601HT7
61.5
69.0
3 phase 60Hz 380V
(A)
Running current
Power consumption (kW)
External dimension
Fan unit
MAP0801HT7
MAP0801HT7
(kW)
Starting current
Compressor
AP2211HT7
AP2201HT7
Hermetic type
1.4 x 2
Propeller fan
12.5
0.6
9,000
Finned tube
8.5
O
/ 22.2
OFF : 2.90
ON : 3.73
( 5)
O
/ 19.1
O
/ 12.7
O
/ 9.5
258
258
4.2 x 2
3.1 x 2
10,500
12.5
*
O
/ 28.6
O
/ 22.2
O
/ 12.7
O
/ 9.5
Brazing
Flare
Gas side
Connecting
Liquid side
method
Balance side
Flare
Max. equivalent length
(m)
175
Max. real length
Max. total pipe length
(Real length)
(m)
150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.)
(m)
300
Max. height difference
(m)
Control wiring
Max. No. of connected indoor units
* 1 : Rated conditions
*
Shield wire 1.25mm2 x 2 cores. up to 2000m
When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and
(Shield wire) 2.0mm2 x 2 cores. up to 2000m
37
Central remote controller
Sound pressure level
Outdoor unit is higher than indoor unit : 50
Outdoor unit is lower than indoor unit : 40 ( 6)
(dB(A))
61.5
Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height.
+ 10%.
* 2 : The source voltage must not fluctuate more than 3
:
The
amount
does
not
consider
extra
piping
lengths.
Refrigerant must be added on site in accordance with the actual piping length.
*
* 4 : The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side.
O
O
O
System safety protection
O
O
O
* 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor,
16
224
High-pressure Sensor, Low pressure sensor, Over-current relay.
* 6 : 30m when the height difference between indoor units exceeds 3m.
60Hz
Equivalent HP
Set Model name
Outdoor unit type
Equivalent to 24HP
MMY-
Heat Pump
Inverter
MMY-
Outdoor unit model Heat Pump
Rated cooling capacity ( 1)
*
*
Standard heating capacity ( 1)
Power supply ( 2)
Running current
*
Electrical
characteristics
( 1)
MAP0801HT7
MAP1201HT7
3 phase 60Hz 380V
40.02
18.44
96
25.02
95
3.69
2.72
1.0
1.0
Running current
(A)
Power consumption (kW)
Power factor
(%)
29.43
18.79
97
33.74
21.32
96
4.07
3.59
1.0
1.0
EER
(kW/kW)
(Energy Efficiency Ratio)
(A)
Starting current
(mm)
(kg)
Total weight
Colour
Height 1,800 x Width 990 x Depth 750
258
258
258
258
258
Silky shade (Munsell 1Y8.5/0.5)
Hermetic type
Type
Motor output
Fan
(kW)
Motor output
Air volume
(kW)
(m3/h)
2.3 x 2
4.2 x 2
Propeller fan
0.6
9,900
10,500
Finned tube
12.5
Heat exchanger
Refrigerant R410A Charged amount ( 3) (kg)
High-pressure switch
(MPa)
*
OFF : 2.90
ON : 3.73
( 5)
Protective devices
Gas side
Connecting
Liquid side
port dia.
Balance side
*
MAP1201HT7
Power consumption (kW)
Power factor
(%)
Cooling
(kW/kW)
EER
(Energy Efficiency Ratio)
Starting current
(A)
External dimension
Refrigerant
pipe spec.
( 4)
MAP0801HT7
68.0
76.5
29.19
Heating
Fan unit
MAP0801HT7
(kW)
(kW)
(A)
*
Compressor
AP2411HT7
AP2401HT7
(mm)
(mm)
O
/ 22.2
*
O
/ 28.6
O
/ 12.7
O
/ 9.5
(mm)
Brazing
Flare
Gas side
Connecting Liquid side
method
Balance side
Max. equivalent length
(m)
Flare
175
Max. real length
(m)
150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.)
Max. total pipe length
(Real length)
(m)
300
Max. height difference
(m)
Control wiring
Central remote controller
Outdoor unit is higher than indoor unit : 50
*
Outdoor unit is lower than indoor unit : 40 ( 6)
Shield wire 1.25mm2 x 2 cores. up to 2000m
When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and
(Shield wire) 2.0mm2 x 2 cores. up to 2000m
Max. No. of connected indoor units
Sound pressure level
* 1 : Rated conditions
40
62
(dB(A))
Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height.
+ 10%.
* 2 : The source voltage must not fluctuate more than * 3 : The amount does not consider extra piping lengths. Refrigerant must be added on site in accordance with the actual piping length.
* 4 : The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side.
O
O
O
O
O
O
System safety protection
* 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor,
High-pressure Sensor, Low pressure sensor, Over-current relay.
* 6 : 30m when the height difference between indoor units exceeds 3m.
16
225
60Hz
Equivalent HP
Set Model name
Outdoor unit type
*
Cooling
Electrical
characteristics
( 1)
Equivalent to 30HP
AP2801HT7
Inverter
AP3001HT7
(kW)
81.5
(A)
Running current
Power consumption (kW)
32.11
20.29
Standard heating capacity ( 1)
Power supply ( 2)
*
Equivalent to 28HP
AP2601HT7
MMY- MAP1001HT7 MAP0801HT7 MAP0801HT7 MAP1001HT7 MAP1001HT7 MAP0801HT7 MAP1001HT7 MAP1001HT7 MAP1001HT7
(kW)
73
78.5
84.0
Outdoor unit model Heat Pump
Rated cooling capacity ( 1)
*
Equivalent to 26HP
MMY-
Heat Pump
(%)
Power factor
EER
(kW/kW)
(Energy Efficiency Ratio)
Starting current
(A)
(%)
Heating Power factor
EER
(kW/kW)
(Energy Efficiency Ratio)
Starting current
External dimension
Total weight
(A)
(mm)
(kg)
Fan unit
1.0
1.0
32.80
20.51
35.77
22.60
38.88
24.82
95
96
97
3.97
3.89
3.83
1.0
Height 1,800 x Width 990 x Depth 750
258
258
258
258
1.0
258
258
Motor output
2.3 x 2
(kW)
Fan
Motor output
(kW)
(m3/h)
*
9,900
10,500
258
258
258
3.1 x 2
Propeller fan
0.6
2.3 x 2
3.1 x 2
10,500
9,900
10,500
Finned tube
12.5
Refrigerant R410A Charged amount ( 3) (kg)
*
1.0
Silky shade (Munsell 1Y8.5/0.5)
Hermetic type
Air volume
Heat exchanger
Refrigerant
pipe spec.
( 4)
3.46
3.52
1.0
Type
High-pressure switch
Protective devices
38.40
24.26
3.60
Colour
Compressor
95.0
96
(A)
Running current
Power consumption (kW)
*
88.0
3 phase 60Hz 380V
35.25
22.27
OFF : 2.90
ON : 3.73
( 5)
(MPa)
*
O
/ 22.2
(mm)
Gas side
Connecting
Liquid side
(mm)
port dia.
Balance side (mm)
Gas side
Connecting
Liquid side
method
Balance side
O
/ 12.7
O
/ 9.5
Brazing
Flare
Max. equivalent length
(m)
Flare
175
Max. real length
(m)
150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.)
Max. total pipe length
(Real length)
(m)
Max. height difference
(m)
Control wiring
Max. No. of connected indoor units
* 1 : Rated conditions
*
Outdoor unit is lower than indoor unit : 40 ( 6)
Shield wire 1.25mm2 x 2 cores. up to 2000m
When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and
(Shield wire) 2.0mm2 x 2 cores. up to 2000m
Central remote controller
Sound pressure level
300
Outdoor unit is higher than indoor unit : 50
(dB(A))
43
62
47
62.5
48
63
Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height.
+ 10%.
* 2 : The source voltage must not fluctuate more than * 3 : The amount does not consider extra piping lengths. Refrigerant must be added on site in accordance with the actual piping length.
* 4 : The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side.
O
O
O
System safety protection
O
O
O
* 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor,
16
226
High-pressure Sensor, Low pressure sensor, Over-current relay.
* 6 : 30m when the height difference between indoor units exceeds 3m.
60Hz
Equivalent to 32HP
Equivalent HP
Set Model name
Outdoor unit type
Heat Pump
Outdoor unit model
Heat Pump
MMY-
Inverter
*
MMY- MAP0801HT7 MAP0801HT7 MAP0801HT7 MAP0801HT7 MAP1201HT7 MAP1001HT7 MAP1001HT7
(kW)
90.0
Rated cooling capacity ( 1)
*
Standard heating capacity ( 1)
Power supply ( 2)
*
Cooling
Electrical
characteristics
( 1)
(kW)
100.0
3 phase 60Hz 380V
39.04
45.34
24.41
95
28.65
96
(kW/kW)
EER
(Energy Efficiency Ratio)
3.69
3.14
Starting current
1.0
1.0
39.28
24.56
42.83
26.78
95
95
4.07
3.73
Running current
Power consumption
(A)
(kW)
(%)
Power factor
Running current
Power consumption
*
(A)
(A)
(kW)
(%)
Heating Power factor
(kW/kW)
EER
(Energy Efficiency Ratio)
Starting current
External dimension
Total weight
1.0
(A)
(mm)
(kg)
1.0
Height 1,800 x Width 990 x Depth 750
258
258
258
Fan unit
Type
(kW)
Motor output
2.3 x 2
(kW)
258
4.2 x 2
258
3.1 x 2
0.6
10,500
9,900
(m3/h)
Finned tube
*
12.5
(kg)
Refrigerant R410A Charged amount ( 3)
High-pressure switch
(MPa)
Protective devices
Gas side
Connecting Liquid side
port dia.
Balance side
OFF : 2.90
ON : 3.73
( 5)
O
/ 22.2
(mm)
*
(mm)
O
/ 12.7
(mm)
O
/ 9.5
Brazing
Gas side
*
258
Propeller fan
Fan
Motor output
Air volume
Heat exchanger
Refrigerant
pipe spec.
( 4)
258
Silky shade (Munsell 1Y8.5/0.5)
Hermetic type
Colour
Compressor
AP3211HT7
AP3201HT7
O
/ 28.6
O
/ 22.2
Connecting
Liquid side
method
Balance side
Max. equivalent length
(m)
Flare
175
Max. real length
(m)
150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.)
Max. total pipe length
(Real length)
(m)
Max. height difference
Flare
(m)
Control wiring
Central remote controller
300
Outdoor unit is higher than indoor unit : 50
*
Outdoor unit is lower than indoor unit : 40 ( 6)
Shield wire 1.25mm2 x 2 cores. up to 2000m
When connecting to outdoor unit : MVVS (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and
MVVS (Shield wire) 2.0mm2 x 2 cores. up to 2000m
Max. No. of connected indoor units
Sound pressure level
* 1 : Rated conditions
48
(dB(A))
63
Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height.
+ 10%.
* 2 : The source voltage must not fluctuate more than * 3 : The amount does not consider extra piping lengths. Refrigerant must be added on site in accordance with the actual piping length.
* 4 : The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side.
O
O
O
O
O
O
System safety protection
* 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor,
High-pressure Sensor, Low pressure sensor, Over-current relay.
* 6 : 30m when the height difference between indoor units exceeds 3m.
16
227
60Hz
Equivalent HP
Equivalent to 34HP
Set Model name
Outdoor unit type
Outdoor unit model
MMY-
Heat Pump
Inverter
MMY- MAP1001HT7 MAP0801HT7 MAP0801HT7 MAP0801HT7 MAP1201HT7 MAP1201HT7 MAP1001HT7
96.0
(kW)
Heat Pump
*
Rated cooling capacity ( 1)
*
*
*
(A)
Running current
Power consumption (kW)
(%)
Power factor
Cooling
EER
(kW/kW)
(Energy Efficiency Ratio)
41.99
26.53
Starting current
(A)
(A)
Power consumption (kW)
(%)
Heating Power factor
(kW/kW)
EER
(Energy Efficiency Ratio)
(A)
Starting current
Running current
External dimension
Fan unit
258
Type
Motor output
Fan
(kW)
3.1 x 2
Motor output
Air volume
(kW)
(m3/h)
Heat exchanger
Refrigerant R410A Charged amount ( 3)
*
High-pressure switch
52.91
96
33.08
95
3.62
2.90
1.0
42.34
1.0
46.75
27.03
97
29.54
96
4.00
3.66
1.0
(mm)
(kg)
Total weight
Colour
Compressor
108.0
3 phase 60Hz 380V
(kW)
Standard heating capacity ( 1)
Power supply ( 2)
Electrical
characteristics
( 1)
1.0
Height 1,800 x Width 990 x Depth 750
258
258
258
Silky shade (Munsell 1Y8.5/0.5)
Hermetic type
258
2.3 x 2
Gas side
*
Connecting Liquid side
port dia.
Balance side
Gas side
Connecting Liquid side
method
Balance side
258
258
4.2 x 2
3.1 x 2
10,500
9,900
O
/ 28.6
O
/ 22.2
Propeller fan
0.6
9,900
10,500
Finned tube
12.5
(kg)
(MPa)
OFF : 2.90
ON : 3.73
( 5)
Protective devices
Refrigerant
pipe spec.
( 4)
AP3411HT7
AP3401HT7
(mm)
O
/ 22.2
*
(mm)
O
/ 12.7
(mm)
O
/ 9.5
Brazing
Flare
Flare
Max. equivalent length
(m)
175
Max. real length
Max. total pipe length
(Real length)
(m)
150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.)
Max. height difference
(m)
300
Outdoor unit is higher than indoor unit : 50
(m)
*
Outdoor unit is lower than indoor unit : 40 ( 6)
Shield wire 1.25mm2 x 2 cores. up to 2000m
Control wiring
When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and
(Shield wire) 2.0mm2 x 2 cores. up to 2000m
48
Central remote controller
Max. No. of connected indoor units
Sound pressure level
* 1 : Rated conditions
(dB(A))
63.5
63.5
Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height.
+ 10%.
* 2 : The source voltage must not fluctuate more than 3
:
The
amount
does
not
consider
extra
piping
lengths.
Refrigerant must be added on site in accordance with the actual piping length.
*
4
:
The
maximum
total
piping
length
indicates
the
sum
of one-way piping lengths on the liquid side or gas side.
*
O
O
O
System safety protection
O
O
O
* 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor,
16
228
High-pressure Sensor, Low pressure sensor, Over-current relay.
6
:
* 30m when the height difference between indoor units exceeds 3m.
60Hz
Equivalent HP
Equivalent to 36HP
Set Model name
Outdoor unit type
Outdoor unit model
Heat Pump
MMY-
Inverter
Heat Pump
*
MMY- MAP1001HT7 MAP1001HT7 MAP0801HT7 MAP0801HT7 MAP1201HT7 MAP1201HT7 MAP1201HT7
101.0
(kW)
Rated cooling capacity ( 1)
*
Standard heating capacity ( 1)
Power supply ( 2)
*
Cooling
Electrical
characteristics
( 1)
113.0
3 phase 60Hz 380V
(kW)
Running current
(A)
Power consumption (kW)
(%)
44.92
28.38
60.06
37.16
96
94
(kW/kW)
EER
(Energy Efficiency Ratio)
3.56
2.72
Starting current
1.0
1.0
45.49
28.74
50.90
31.49
96
94
3.93
3.59
Power factor
(A)
Running current
(A)
Power consumption (kW)
*
(%)
Heating Power factor
(kW/kW)
EER
(Energy Efficiency Ratio)
Starting current
External dimension
Total weight
(A)
(mm)
(kg)
1.0
1.0
Height 1,800 x Width 990 x Depth 750
258
258
258
Fan unit
Type
(kW)
Motor output
Fan
Motor output
*
Refrigerant R410A Charged amount ( 3)
Refrigerant
pipe spec.
( 4)
*
Gas side
Connecting Liquid side
port dia.
Balance side
Gas side
Connecting
Liquid side
method
Balance side
Max. equivalent length
Max. real length
Max. total pipe length
(Real length)
Max. height difference
4.2 x 2
10,500
9,900
Finned tube
10,500
258
12.5
(kg)
OFF : 2.90
ON : 3.73
( 5)
O
/ 22.2
(mm)
*
(mm)
O
/ 12.7
(mm)
O
/ 9.5
Brazing
O
/ 28.6
Flare
(m)
Flare
175
(m)
150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.)
(m)
300
Outdoor unit is higher than indoor unit : 50
(m)
Central remote controller
* 1 : Rated conditions
258
2.3 x 2
Propeller fan
0.6
(MPa)
Control wiring
Max. No. of connected indoor units
Sound pressure level
258
3.1 x 2
(kW)
(m3/h)
Air volume
Heat exchanger
High-pressure switch
Protective devices
258
Silky shade (Munsell 1Y8.5/0.5)
Hermetic type
Colour
Compressor
AP3611HT7
AP3601HT7
(dB(A))
*
Outdoor unit is lower than indoor unit : 40 ( 6)
Shield wire 1.25mm2 x 2 cores. up to 2000m
When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and
(Shield wire) 2.0mm2 x 2 cores. up to 2000m
48
64
63.5
Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height.
+ 10%.
* 2 : The source voltage must not fluctuate more than * 3 : The amount does not consider extra piping lengths. Refrigerant must be added on site in accordance with the actual piping length.
* 4 : The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side.
O
O
O
O
O
O
System safety protection
* 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor,
High-pressure Sensor, Low pressure sensor, Over-current relay.
* 6 : 30m when the height difference between indoor units exceeds 3m.
16
229
60Hz
Equivalent to 38HP
Equivalent HP
Set Model name
Outdoor unit type
Heat Pump
MMY-
*
MMY- MAP1001HT7 MAP1001HT7 MAP1001HT7 MAP0801HT7 MAP1001HT7 MAP1001HT7 MAP1001HT7 MAP1001HT7
(kW)
112.0
106.5
*
Standard heating capacity ( 1)
Power supply ( 2)
Running current
Power consumption
*
Electrical
characteristics
( 1)
*
Power factor
Fan unit
(A)
(kW)
(%)
51.18
32.34
48.05
30.36
96
1.0
1.0
48.79
30.83
52.31
33.05
(A)
(A)
(kW)
3.46
(%)
96
EER
(kW/kW)
(Energy Efficiency Ratio)
(A)
Starting current
(mm)
(kg)
3.83
3.88
1.0
1.0
Height 1,800 x Width 990 x Depth 750
258
258
258
258
258
258
258
258
Silky shade (Munsell 1Y8.5/0.5)
Hermetic type
Type
Motor output
Fan
(kW)
(m3/h)
*
High-pressure switch
Protective devices
Gas side
Connecting
Liquid side
port dia.
Balance side
Gas side
Connecting
Liquid side
method
Balance side
Max. equivalent length
Max. real length
Max. total pipe length
(Real length)
Max. height difference
3.1 x 2
2.3 x 2
Propeller fan
10,500
9,900
Finned tube
(kW)
Motor output
Refrigerant R410A Charged amount ( 3)
*
3 phase 60Hz 380V
3.51
Air volume
Heat exchanger
Refrigerant
pipe spec.
( 4)
126.5
119.5
Starting current
Total weight
Colour
Compressor
(kW)
EER
(kW/kW)
(Energy Efficiency Ratio)
Running current
Power consumption
Heating Power factor
External dimension
AP4001HT7
Inverter
Heat Pump
Outdoor unit model
Rated cooling capacity ( 1)
Cooling
Equivalent to 40HP
AP3801HT7
0.6
(kg)
12.5
OFF : 2.90
ON : 3.73
( 5)
(mm)
O
/ 22.2
(mm)
(mm)
O
/ 12.7
*
O
/ 9.5
Brazing
Flare
Flare
(m)
175
(m)
150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.)
(m)
300
(m)
Outdoor unit is higher than indoor unit : 50
Outdoor unit is lower than indoor unit : 40 ( 6)
*
Shield wire 1.25mm2 x 2 cores. up to 2000m
When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and
(Shield wire) 2.0mm2 x 2 cores. up to 2000m
Central remote controller
Max. No. of connected indoor units
* 1 : Rated conditions
10,500
(MPa)
Control wiring
Sound pressure level
3.1 x 2
48
64
(dB(A))
Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height.
+ 10%.
* 2 : The source voltage must not fluctuate more than 3
:
The
amount
does
not
consider
extra
piping
lengths.
Refrigerant must be added on site in accordance with the actual piping length.
*
4
:
The
maximum
total
piping
length
indicates
the
sum
of one-way piping lengths on the liquid side or gas side.
*
O
O
O
System safety protection
O
O
O
* 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor,
16
230
High-pressure Sensor, Low pressure sensor, Over-current relay.
6
:
* 30m when the height difference between indoor units exceeds 3m.
60Hz
Equivalent to 44HP
Equivalent to 42HP
Equivalent HP
Set Model name
Outdoor unit type
Heat Pump
Outdoor unit model
Heat Pump
MMY-
AP4401HT7
AP4201HT7
Inverter
MMY- MAP1201HT7 MAP1001HT7 MAP1001HT7 MAP1001HT7 MAP1201HT7 MAP1201HT7 MAP1001HT7 MAP1001HT7
(kW)
123.5
118.0
(kW)
138.0
132.0
3 phase 60Hz 380V
60.56
58.15
Running current
(A)
Power consumption (kW)
40.99
36.74
*
Rated cooling capacity ( 1)
Standard heating capacity ( 1)
Power supply ( 2)
*
Cooling
*
(%)
Power factor
(kW/kW)
EER
(Energy Efficiency Ratio)
Electrical
Starting current
(A)
characteristics
Running current
(A)
( 1)
Power consumption (kW)
(%)
Heating Power factor
EER
(kW/kW)
(Energy Efficiency Ratio)
Starting current
(A)
*
External dimension
Compressor
Fan unit
Type
Motor output
Fan
Motor output
Air volume
95
3.01
1.0
1.0
56.20
35.14
59.75
37.36
95
3.76
3.69
1.0
(mm)
Total weight
Colour
96
3.21
1.0
Height 1,800 x Width 990 x Depth 750
(kg)
258
(kW)
4.2 x 2
258
258
258
(kW)
(m3/h)
*
Connecting Liquid side
port dia.
Balance side
(mm)
3.1 x 2
12.5
OFF : 2.90
ON : 3.73
( 5)
Protective devices
Gas side
4.2 x 2
Propeller fan
0.6
10,500
Finned tube
(kg)
Refrigerant R410A Charged amount ( 3)
High-pressure switch
(MPa)
*
258
Hermetic type
3.1 x 2
Heat exchanger
Refrigerant
pipe spec.
( 4)
258
258
258
Silky shade (Munsell 1Y8.5/0.5)
O
/ 28.6
O
/ 22.2
(mm)
(mm)
*
O
/ 28.6
O
/ 22.2
O
/ 12.7
O
/ 9.5
Brazing
Flare
Gas side
Connecting Liquid side
method
Balance side
Flare
Max. equivalent length
(m)
175
Max. real length
(m)
150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.)
Max. total pipe length
(Real length)
(m)
300
(m)
Outdoor unit is higher than indoor unit : 50
Outdoor unit is lower than indoor unit : 40 ( 6)
Max. height difference
Control wiring
Central remote controller
Max. No. of connected indoor units
Sound pressure level
* 1 : Rated conditions
*
Shield wire 1.25mm2 x 2 cores. up to 2000m
When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and
(Shield wire) 2.0mm2 x 2 cores. up to 2000m
48
64.5
(dB(A))
Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height.
+ 10%.
* 2 : The source voltage must not fluctuate more than 3
:
The
amount
does
not
consider
extra
piping
lengths.
Refrigerant must be added on site in accordance with the actual piping length.
*
4
:
The
maximum
total
piping
length
indicates
the
sum
of one-way piping lengths on the liquid side or gas side.
*
O
O
O
O
O
O
System safety protection
* 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor,
High-pressure Sensor, Low pressure sensor, Over-current relay.
6
:
* 30m when the height difference between indoor units exceeds 3m.
16
231
60Hz
Equivalent HP
Set Model name
Outdoor unit type
Outdoor unit model
Equivalent to 46HP
Heat Pump
MMY-
Equivalent to 48HP
AP4601HT7
AP4801HT7
Inverter
Heat Pump
Rated cooling capacity ( 1)
MMY- MAP1201HT7 MAP1201HT7 MAP1201HT7 MAP1001HT7 MAP1201HT7 MAP1201HT7 MAP1201HT7 MAP1201HT7
(kW)
135.0
130.0
Standard heating capacity ( 1)
(kW)
150.0
145
Power supply ( 2)
3 phase 60Hz 380V
Running current
(A)
72.92
79.44
Power consumption (kW)
45.59
49.67
(%)
Power
factor
95
Cooling
*
*
*
Electrical
characteristics
( 1)
*
(kW/kW)
EER
(Energy Efficiency Ratio)
2.85
(A)
1.0
1.0
63.73
39.85
95
67.56
41.80
94
3.64
3.59
Starting current
(A)
Power consumption (kW)
Power factor
(%)
Heating
(kW/kW)
EER
(Energy Efficiency Ratio)
Running current
Starting current
External dimension
(A)
(mm)
(kg)
Total weight
2.72
1.0
1.0
Height 1,800 x Width 990 x Depth 750
258
258
258
Colour
Compressor
Fan unit
Type
(kW)
Motor output
Fan
Motor output
Air volume
Heat exchanger
*
Refrigerant R410A Charged amount ( 3)
High-pressure switch
Protective devices
Gas side
Connecting
Liquid side
port dia.
Balance side
3.1 x 2
Propeller fan
4.2 x 2
(kW)
0.6
(m3/h)
10,500
Finned tube
(kg)
(mm)
*
258
258
4.2 x 2
12.5
(MPa)
OFF : 2.90
ON : 3.73
( 5)
O
/ 28.6
O
/ 22.2
*
O
/ 28.6
O
/ 12.7
(mm)
(mm)
O
/ 9.5
Brazing
Gas side
Refrigerant
pipe spec.
( 4)
258
258
258
Silky shade (Munsell 1Y8.5/0.5)
Hermetic type
Connecting
Liquid side
method
Balance side
Flare
Flare
Max. equivalent length
(m)
160
Max. real length
Max. total pipe length
(Real length)
(m)
135 (If the total bend length exceeds 135m, use the max equivalent length as the standard.)
Max. height difference
(m)
300
(m)
Outdoor unit is higher than indoor unit : 50
Outdoor unit is lower than indoor unit : 40 ( 6)
*
Shield wire 1.25mm2 x 2 cores. up to 2000m
When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and
(Shield wire) 2.0mm2 x 2 cores. up to 2000m
Control wiring
Central remote controller
48
Max. No. of connected indoor units
Sound pressure level
* 1 : Rated conditions
(dB(A))
65
Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height.
+ 10%.
* 2 : The source voltage must not fluctuate more than 3
:
The
amount
does
not
consider
extra
piping
lengths.
Refrigerant must be added on site in accordance with the actual piping length.
*
4
:
The
maximum
total
piping
length
indicates
the
sum
of one-way piping lengths on the liquid side or gas side.
*
O
O
O
System safety protection
O
O
O
* 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor,
16
232
High-pressure Sensor, Low pressure sensor, Over-current relay.
6
:
* 30m when the height difference between indoor units exceeds 3m.
Oct. 05’
Engineering Data
High Wall Type
( 2 Series )
Indoor Unit
MMK-AP0072H
MMK-AP0092H
MMK-AP0122H
1. Equipments
2. Technical Specifications
3. Dimensional Drawing
4. Wiring Diagram
5. Refrigerant Cycle Diagram
6. Sensible Capacity Table
7. Fan characteristics
8. Sound Characteristics (NC curve)
9. Wireless Remote controller
A-1
A-2
1. Equipment
1-1. Line up
Type
Appearance
High Wall type
(2 series)
MMK-AP0072H
007 type
0.8
2.2
2.5
MMK-AP0092H
009 type
1.0
2.8
3.2
MMK-AP0122H
012 type
1.25
3.6
4.0
Appearance
(Packed with the indoor unit)
Application
Function
Start / Stop
Changing mode
Temperature setting
Air flow changing (5 step)
Clock
Timer function
- ON/OFF timer (10 min. step)
- Daily timer
High power mode
ECO mode (Sleep timer with ECO-logic)
One-touch pre-set memory
One-touch Auto (*1)
WH-H2UE
Wireless remote controller
Model
name
Cooling
Heating
Capacity (kW) Capacity (kW)
Capacity
rank
1-2. Remote controller
Name
Capacity
code
Model Name
(Note.1) Super MMS can not accept “AUTO” mode, Super HRM can accept “AUTO” mode.
1-3. Wiring Design
Model
Nominal Voltage
50Hz
Voltage
Fan Motor
Power Supply
(V-Ph-Hz)
Min
Max
kW
FLA
MCA
MOCP
MMK-AP0072H
230-1-50
198
264
0.03
0.20
0.24
15
MMK-AP0092H
230-1-50
198
264
0.03
0.21
0.26
15
MMK-AP0122H
230-1-50
198
264
0.03
0.22
0.27
15
Legend
MCA
MOCP
: Minimum Circuit Amps
: Maximum Overcurrent Protection (Amps)
FLA
kW
: Full Load Amps
: Fan Motor Rated Output (kW)
1-4. Accessories
Accessory parts name
Model
Remarks
Wired remote controller
RBC-AMT31E
Simple remote controller
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E2
with separated receiver unit
Central remote controller
TCB-SC642TLE2
Max. 64 group / unit
Weekly timer
RBC-EXW21E2
Use with RBC-AMT31E
A-31
2. Technical Specifications
50Hz
High Wall type (2 Series)
Model name
MMK-
Cooling / Heating capacity (Note 1)
(kW)
Electrical
Running current
Characteristics Power consumption
Starting current
Outer
dimension
AP0092H
AP0122H
2.2 / 2.5
2.8 / 3.2
3.6 / 4.0
1 phase 50Hz 230V (220-240V)
(Power exclusive for indoor is required.)
Power Supply
Appearance
AP0072H
(A)
0.17
0.18
0.19
(kW)
0.017
0.018
0.019
(A)
0.22
0.23
0.24
Suction grille and side panel
Moon white
Discharge grille
Moon white
Bottom surface
Moon white
Height x Width x Depth
Total weight
(mm)
275 x 790 x 208
(kg)
11
Heat exchanger
Finned tube
Soundproof/Heat-insulating material
Non-flammable insulation
Cross-flow fan
Fan
Fan unit
Standard air flow (High/Mid/Low)(m3/h)
480 / 420 /360
Motor
30
Air filter
Standard filter attached (Simple filter)
Controller
Connecting
pipe
(Note 3)
Gas side
Liquid side
Drain port
Sound level (Note 2) (High / Mid / Low)
2
A-4
510 / 450 / 360 540 / 450 / 360
Note 1
:
Note 2
:
Note 3
:
Note 4
:
Wireless remote controller
(WH-H2UE, Packed with indoor unit)
9.5
(mm)
6.4
(mm)
16 (Polyvinyl chloride tube)
(Outer dia.)
(dB(A))
35-32-29
36-33-29
37-33-29
The cooling capacities and electrical characteristics are measured under the
conditions specified by JIS B 8615 based on the reference piping. The reference
piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0
meter height.
The sound level are measured in an anechoic chamber in accordance with JIS
B8616.
Normally, the values measured in the actual operating environment become larger
than the indicated values due to the effects of external sound.
Wireless remote controller is packed with indoor unit.
Wired remote controller (RBC-AMT31E,RBC-AS21E2) can be also connected.
Rated conditions
Cooling : Indoor air temperature 27 C DB/19 C WB,
Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20C DB,
Outdoor air temperature 7C DB/6C WB
3. Dimensional Drawing
Model : MMK-AP0072H, AP0092H, AP0122H
Air inlet port
790
275
275
208
275
208
Knockout
60
48
Air outlet port
6
6
60
48
Knockout
54.5
60
60
48
48
208
790
54.5
790
275
Wired remote controller
RBC-AMT21E
RBC-AMT31E
Simple wired remote controller
RBC-AS21E
RBC-AS21E2
Wireless remote controller kit
RBC-AX22CE
RBC-AX22CE2
208
790
Tab for insulation plate
Refrigerant pipe connecting port
Gas side O9.5
321
Drain pipe
Refrigerant pipe connecting port
Liquid side O6.4
(Installation space)
100mm or more
170mm or more
170mm or more
*300mm or more
*(For attached Flow Selector unit
when used in heat recovery model)
Note : All dimensions are in mm.
A-53
4. Wiring Diagram
Model : MMK-AP0072H, AP0092H, AP0122H
4
A-6
5. Refrigerant Cycle Diagram
Model : MMK-AP0072H, AP0092H, AP0122H
Liquid side
Gas side
Strainer
Capillary tube
Air heat exchanger
at indoor side
Pulse Motor
Valve (PMV)
Sensor
(TC2)
Sensor
(TCJ)
Fan
Sensor
(TC1)
Sensor
(TA)
Functional part name
Fan motor
Functional outline
Pulse Motor
Valve
(PMV)
PMV
(Connector CN082 (6P): Blue)
1) Controls super heat in cooling operation
2) Controls under cool in heating operation
3) Recovers refrigerant oil in cooling operation
4) Recovers refrigerant oil in heating operation
Temp. sensor
1.TA
(Connector CN104 (2P): Yellow)
1) Detects indoor suction temperature
2.TC1
(Connector CN100 (3P): Brown)
1) Controls PMV super heat in cooling operation
3.TC2
(Connector CN101 (2P): Black
1) Controls PMV under cool in heating operation
4.TCJ
(Connector CN102 (2P): Red)
1) Controls PMV super heat in cooling operation
A-75
6. Sensible Capacity Table
High Wall Type ( MMK-AP****2H ) 2 series
TC: Total capacity [kW]
SHC: Sensible capacity [kW]
Indoor Air Temp.
unit outdoor
size air temp.
007
009
012
6
A-8
14.0CWB
16.0CWB
18.0CWB
19.0CWB
20.0CWB
22.0CWB
20CDB
23CDB
26CDB
27CDB
28CDB
30CDB
24.0CWB
32CDB
CDB
TC
SHC
TC
SHC
TC
SHC
TC
SHC
TC
SHC
TC
SHC
TC
SHC
10.0
1.8
1.5
2.0
1.6
2.1
1.7
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
12.0
1.8
1.5
2.0
1.6
2.1
1.7
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
14.0
1.8
1.5
2.0
1.6
2.1
1.7
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
16.0
1.8
1.5
2.0
1.6
2.1
1.7
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
18.0
1.8
1.5
2.0
1.6
2.1
1.7
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
20.0
1.8
1.5
2.0
1.6
2.1
1.7
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
21.0
1.8
1.5
2.0
1.6
2.1
1.7
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
23.0
1.8
1.5
2.0
1.6
2.1
1.7
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
25.0
1.8
1.5
2.0
1.6
2.1
1.7
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
27.0
1.8
1.5
2.0
1.6
2.1
1.7
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
29.0
1.8
1.5
2.0
1.6
2.1
1.7
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
31.0
1.8
1.5
2.0
1.6
2.1
1.7
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
33.0
1.8
1.5
2.0
1.6
2.1
1.7
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
35.0
1.8
1.5
2.0
1.6
2.1
1.7
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
37.0
1.7
1.5
1.9
1.6
2.1
1.7
2.1
1.6
2.2
1.6
2.3
1.6
2.4
1.6
39.0
1.7
1.4
1.9
1.5
2.0
1.6
2.1
1.6
2.1
1.6
2.3
1.6
2.4
1.5
10.0
2.3
1.8
2.5
1.9
2.7
2.0
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
12.0
2.3
1.8
2.5
1.9
2.7
2.0
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
14.0
2.3
1.8
2.5
1.9
2.7
2.0
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
16.0
2.3
1.8
2.5
1.9
2.7
2.0
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
18.0
2.3
1.8
2.5
1.9
2.7
2.0
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
20.0
2.3
1.8
2.5
1.9
2.7
2.0
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
21.0
2.3
1.8
2.5
1.9
2.7
2.0
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
23.0
2.3
1.8
2.5
1.9
2.7
2.0
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
25.0
2.3
1.8
2.5
1.9
2.7
2.0
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
27.0
2.3
1.8
2.5
1.9
2.7
2.0
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
29.0
2.3
1.8
2.5
1.9
2.7
2.0
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
31.0
2.3
1.8
2.5
1.9
2.7
2.0
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
33.0
2.3
1.8
2.5
1.9
2.7
2.0
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
35.0
2.3
1.8
2.5
1.9
2.7
2.0
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
37.0
2.2
1.7
2.5
1.8
2.6
1.9
2.7
1.9
2.8
1.9
3.0
1.9
3.1
1.9
39.0
2.2
1.7
2.4
1.8
2.6
1.9
2.6
1.9
2.7
1.9
2.9
1.9
3.0
1.8
10.0
3.0
2.2
3.3
2.4
3.5
2.5
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
12.0
3.0
2.2
3.3
2.4
3.5
2.5
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
14.0
3.0
2.2
3.3
2.4
3.5
2.5
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
16.0
3.0
2.2
3.3
2.4
3.5
2.5
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
18.0
3.0
2.2
3.3
2.4
3.5
2.5
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
20.0
3.0
2.2
3.3
2.4
3.5
2.5
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
21.0
3.0
2.2
3.3
2.4
3.5
2.5
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
23.0
3.0
2.2
3.3
2.4
3.5
2.5
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
25.0
3.0
2.2
3.3
2.4
3.5
2.5
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
27.0
3.0
2.2
3.3
2.4
3.5
2.5
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
29.0
3.0
2.2
3.3
2.4
3.5
2.5
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
31.0
3.0
2.2
3.3
2.4
3.5
2.5
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
33.0
3.0
2.2
3.3
2.4
3.5
2.5
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
35.0
3.0
2.2
3.3
2.4
3.5
2.5
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
37.0
2.9
2.1
3.2
2.3
3.4
2.4
3.5
2.4
3.6
2.4
3.8
2.4
4.0
2.3
39.0
2.8
2.1
3.1
2.2
3.3
2.4
3.4
2.4
3.5
2.4
3.7
2.3
3.9
2.3
7. Fan Characteristics
Discharge Air Speed and Air Throw
High Wall Type (2 series)
Model : MMK-AP0072H, AP0092H, AP0122H
Horizontal discharge Initial speed
High wind : 4.5m/s
Med wind : 3.7m/s
Low wind : 3.2m/s
Air speed (m/s)
5
4
High
Mid
Low
3
2
1
0
0
1
2
3
4
5
6
7
Horizontal throw (m)
A-97
8. Sound Characteristics (NC curve)
High Wall Type (2 series)
Model : MMK-AP0072H, AP0092H, AP0122H
1m
1m
Microphone
MMK-AP0072H
Fan tap
H
M
L
Sound pressure level (dB(A))
35
32
29
Octave band sound pressure level (dB)
90
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
20
10
20-75
NC-30
Audibility limits of
continuous white level
75-150
NC-20
150-300
300-600
600-1200
1200-2400
Octave band frequency (Hz)
8
A-10
2400-4800
4800-10000
MMK-AP0092H
Fan tap
H
M
L
Sound pressure level (dB(A))
36
33
29
Octave band sound pressure level (dB)
90
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
20
10
20-75
NC-30
Audibility limits of
continuous white level
75-150
NC-20
150-300
300-600
600-1200
1200-2400
2400-4800
4800-10000
Octave band frequency (Hz)
MMK-AP0122H
Fan tap
H
M
L
Sound pressure level (dB(A))
35
33
29
Octave band sound pressure level (dB)
90
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
20
10
20-75
NC-30
Audibility limits of
continuous white level
75-150
NC-20
150-300
300-600
600-1200
1200-2400
2400-4800
4800-10000
Octave band frequency (Hz)
A-11
9
9. Wireless Remote controller
High wall (1 series)
High Wall (2 series)
TCB-AX21E2(sold
TCB-AX21E (Sold Separately)
WH-H2UE
External View
Function
Button
Start/Stop
Setting
temp.
Start/Stop
Contents
Button
OK
START/STOP
Contents
OK
AUTO
17~27 °C
17~30 °C
COOL
18~30 °C
17~30 °C
DRY
18~30 °C
17~30 °C
16~26 °C
17~30 °C
HEAT
Fahrenheit display
-
Air Volume Control
Flap
Swing
Swing/Frap
OK
-
-
3-Speed, Auto
FAN
5-Speed, Auto
FIX
OK
SWING
OK
MODE
Auto,Cool,Dry,
Heat, Fan
OK
Auto, Heat, Dry,
Cool, Fan
Operation select
Remarks
No Fahrenheit display function
5-step control
No switch setting for
cooling only
One-touch auto ( Auto mode,
One-touch Auto Setting temperature :22 °C,
Air volume : Auto, Flap
position : Auto, Swing : Off)
One-touch Auto
-
-
AUTO
Preset mode
-
-
MEMO /
PRESET
OK
Clock
-
-
CLOCK
OK
OFF timer, ON timer,
Clock display
Repeat timer, 30
ON/OFF/SET system,
minutes interval,
10 minutes interval,
max. 72 hours,
max. 24 hours,
Memorizing of setting contents
for preset mode freely.
Available for ON / OFF
working together
ON/OFF timer
SET
ECONO mode
-
-
ECO
OK
Sleep timer with ECO logic
Daily timer
-
-
ON/OFF/SET
OK
Setting both ON and OFF
timer simultaneously and
daily
CL
OK
-
-
Filter reset
Filter reset
Reset
Reset
Timer cancel
High Power mode
Sensor button
SENSOR
OK
-
Hi-POWER
OK
Automatic controls for quick
cooling and heating
OK
FILTER
OK
-
OK
RESET
OK
-
OK
-
-
No remote controller sensor
(Note)
1. Automatic operation mode can not be accepted by heat pump system. If transmission is sent as auto mode, operation lamp and
timer lamp of the indoor unit will light up with a beep as notification. In this case, change the other operation mode.
(Heat recovery system can accept automatic operation by using this wireless remote controller.)
2. Group control using the wired remote controller (WH-H2UE) is not available. If it is incorrect action or display disagreement
may occur.
3. A wired remote controller is required for the group control. (sold separately.)
4. When the wired remote controller is connected to this high wall unit, two remote control with the wireless remote controller
(WH-H2UE) can be used. In this case, last-push priority control is performed.
5. When the unit is controlled in a group through a wired control, ECO-Timer and Hi-POWER operation will not function.
10
A-12
Oct. 05’
Engineering Data
1-way (2 series)
Air Discharge Cassette Type
Indoor Unit
MMU-AP0152SH
MMU-AP0182SH
MMU-AP0242SH
Contents
1. Specifications
2. Dimensions
3. Electrical current characteristics
4. Sensible capacity table
5. Wiring diagrams
6. Air speed characteristics
7. Sound characteristics (NC Curve)
8. Fresh air intake (Design guide)
9. Barycentric position
A-13
A-14
1. Specification
1-way (2 series) Air Discharge Cassette Type
50Hz
Model name
MMUAP0152SH
AP0182SH
AP0242SH
Cooling/Heating capacity
(kW)
4.5/5.0
5.6/6.3
7.1/8.0
Electrical
Power supply
1 phase 50Hz 230V (220-240V)
characteristics
Running current
(A)
0.34
0.37
0.62
Power consumption
(kW)
0.042
0.046
0.075
Starting current
(A)
0.51
0.54
0.80
Appearance
Main unit
Heat-insulating material attached Zinc hot dipping steel plate
Ceiling panel
RBC-US21PGE
Panel color
Moon white (Munsel 2.5GY9.0/0.5)
Dimension
Main unit
Height
(mm)
200
Total weight
Width
Depth
Ceiling panel Height
Width
Depth
Main unit
Ceiling panel
(mm)
(mm)
(mm)
(mm)
(mm)
(kg)
(kg)
1000
710
20
1230
800
21
22
5.5
Finned tube
Polyethylene foam + Expanded polystyrene
Centrifugal fan (Sirocco fan)
3
(m /h)
750
780
1140
(m3/h)
690/630
720/660
960/810
Motor
(W)
30
Air filter
Standard filter attached (Long life filter)
Controller
Remote controller
Connecting pipe
Gas pipe
(mm)
12.7
15.9
Liquid pipe
(mm)
6.4
9.5
Drain pipe (Nominal dia.mm) 25 (Polyvinyl chloride tube : External dia.32 Internal dia.25)
Sound pressure level High/Mid./Low
(dB(A))
37/35/32
38/36/34
45/41/37
Heat exchanger
Soundproof / Heat-insulating material
Fan
High
Standard air flow
(Mid./Low)
A-15
1
1. Specification
1-way (2 series) Air Discharge Cassette Type
60Hz
Model name
MMUAP0152SH
AP0182SH
AP0242SH
Cooling/Heating capacity
(kW)
4.5/5.0
5.6/6.3
7.1/8.0
Electrical
Power supply
1 phase 60Hz 220V
characteristics
Running current
(A)
0.35
0.39
0.62
Power consumption
(kW)
0.041
0.045
0.073
Starting current
(A)
0.53
0.54
0.80
Appearance
Main unit
Heat-insulating material attached Zinc hot dipping steel plate
Ceiling panel
RBC-US21PGE
Panel color
Moon white (Munsel 2.5GY9.0/0.5)
Dimension
Main unit
Height
(mm)
200
Total weight
Width
Depth
Ceiling panel Height
Width
Depth
Main unit
Ceiling panel
(mm)
(mm)
(mm)
(mm)
(mm)
(kg)
(kg)
1000
710
20
1230
800
21
22
5.5
Finned tube
Polyethylene foam + Expanded polystyrene
Centrifugal fan (Sirocco fan)
3
(m /h)
750
780
1140
(m3/h)
690/630
720/660
960/810
Motor
(W)
30
Air filter
Standard filter attached (Long life filter)
Controller
Remote controller
Connecting pipe
Gas pipe
(mm)
12.7
15.9
Liquid pipe
(mm)
6.4
9.5
Drain pipe (Nominal dia.mm) 25 (Polyvinyl chloride tube : External dia.32 Internal dia.25)
Sound pressure level High/Mid./Low
(dB(A))
37/35/32
38/36/34
45/41/37
Heat exchanger
Soundproof / Heat-insulating material
Fan
High
Standard air flow
(Mid./Low)
2
A-16
2. Dimensions
1-way (2 series) Air Discharge Cassette Type (MMU-AP***SH)
56
Cable inlet (Knockout hole)
252
248
Drain pipe connecting port
(Be sure to connect the attached flexible hose.)
112
72
Fresh air inlet (Ø92 knockout hole)
20
C/L
1060 Hanging bolt pitch
1190 Ceiling opening size
1230 Panel external size
20
1000 Unit external size
706
20
216
800 Panel external size
20
135
220
760 Ceiling opening size
475 Hanging bolt pitch
233
122
710 Unit external size
C/L
80 60
43
Cable inlet
100
Ø112 (4-tapping screw under-hole)
94
154
Refrigerant pipe connecting port
Gas side B
Refrigerant pipe connecting port
Liquid side A
20
73.4
93
200
76
Hanging bolt M10 or W3/8 (Local supply)
Lower surface of ceiling
Ceiling panel (Sold separately)
Model name MMU-
A
B
AP015, AP018 type
Ø6.4
Ø12.7
AP024 type
Ø9.5
Ø15.9
120
2.7
Wired remote controller
RBC-AMT21E 4
RBC-AMT31E
Simple wired remote controller
RBC-AS21E
RBC-AS21E2
Wireless remote controller kit
16
TCB-AX21E
120
TCB-AX21E2
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
For front air discharge unit (Sold separately) knockout hole
A-17
3
3. Electrical current characteristics
1-way (2 series) Air Discharge Cassette Type
4
A-18
Type
Model
Nominal Voltage Voltage Range
(V-Ph-Hz)
Min
Max
230-1-50
198
264
230-1-50
198
264
230-1-50
198
264
S-MMS (50Hz)
MMU-AP0152SH
MMU-AP0182SH
MMU-AP0242SH
S-MMS (60Hz)
MMU-AP0152SH
MMU-AP0182SH
MMU-AP0242SH
220-1-60
220-1-60
220-1-60
198
198
198
S-HRM
MMU-AP0152SH
MMU-AP0182SH
MMU-AP0242SH
230-1-50
230-1-50
230-1-50
198
198
198
Fan Motor
kW
FLA
0.030
0.40
0.030
0.42
0.030
0.71
Power Supply
MCA MOCP
0.49
15
0.53
15
0.88
15
264
264
264
0.030
0.030
0.030
0.40
0.45
0.75
0.50
0.57
0.94
15
15
15
264
264
264
0.030
0.030
0.030
0.40
0.42
0.71
0.49
0.53
0.88
15
15
15
4. Sensible capacity table
1-way (2 series) Air Discharge Cassette Type (MMU-AP***SH)
14.0CWB
20CDB
TC
SHC
16.0CWB
23CDB
TC
SHC
TC : Total capacity [kW] SHC : Sensible capacity [kW]
Indoor air temp.
18.0CWB
19.0CWB
20.0CWB
22.0CWB
24.0CWB
26CDB
27CDB
28CDB
30CDB
32CDB
TC
SHC
TC
SHC
TC
SHC
TC
SHC
TC
SHC
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.6
3.5
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.7
2.7
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.0
3.8
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
2.9
2.8
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.2
4.1
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.1
3.0
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.4
4.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.1
3.0
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.5
4.4
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.1
3.0
4.9
4.9
4.9
4.9
4.9
4.9
4.9
4.9
4.9
4.9
4.9
4.9
4.9
4.9
4.7
4.6
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.1
3.0
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.0
4.8
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.0
2.9
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.5
4.3
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.3
3.3
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
4.9
4.8
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.6
3.5
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.3
5.1
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.8
3.7
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.4
5.3
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.8
3.7
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.6
5.4
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.8
3.7
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
5.9
5.7
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.7
3.6
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.2
6.0
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.7
3.6
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.6
5.5
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.3
4.2
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.2
6.1
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.6
4.4
6.9
6.9
6.9
6.9
6.9
6.9
6.9
6.9
6.9
6.9
6.9
6.9
6.9
6.9
6.7
6.5
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
4.9
4.7
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
6.9
6.7
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
4.8
4.7
7.3
7.3
7.3
7.3
7.3
7.3
7.3
7.3
7.3
7.3
7.3
7.3
7.3
7.3
7.1
6.9
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
4.8
4.7
7.7
7.7
7.7
7.7
7.7
7.7
7.7
7.7
7.7
7.7
7.7
7.7
7.7
7.7
7.5
7.3
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
4.8
4.7
8.1
8.1
8.1
8.1
8.1
8.1
8.1
8.1
8.1
8.1
8.1
8.1
8.1
8.1
7.8
7.6
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.7
4.6
Unit Outdoor
size air temp.
CDB
015
018
024
A-19
5
5. Wiring diagrams
on side
1-way (2 series) Air Discharge Cassette Type (MMU-AP***SH)
6
A-20
6. Air speed characteristics
1-way (2 series) Air Discharge Cassette Type
Heating mode
MMU-AP0152SH, AP0182SH
3.5m
Main unit
3m
2m
1m
0.3
1.0
0.3
0.5
0.5
1m
2m
3m
4m
MMU-AP0242SH
3.5m
Main unit
3m
2m
0.3
1.0
1m
0.3
0.5
0.5
1m
2m
3m
4m
A-21
7
7. Sound Characteristics (NC Curve)
1-way (2 series) Air Discharge Cassette Type
MMU-AP0242SH
MMU-AP0152SH
Fan tap
Sound pressure
level (dB(A))
H
M
L
37
35
32
Fan tap
Sound pressure
level (dB(A))
M
L
45
41
37
90
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
H
30
M
NC-30
L
20
Approximate threshold of
hearing for continuous noise
NC-20
10
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
90
H
80
70
NC-70
60
NC-60
50
NC-50
40
H
M
NC-40
30
L
NC-30
20
Approximate threshold of
hearing for continuous noise
NC-20
10
63
125
250
500 1000 2000 4000 8000
Octave band center frequency (Hz)
63
125
250
500 1000 2000 4000 8000
Octave band center frequency (Hz)
MMU-AP0182SH
Fan tap
Sound pressure
level (dB(A))
H
M
L
38
36
34
Octave band sound pressure level (dB)
90
80
70
NC-70
60
NC-60
50
NC-50
40
H M
30
L
20
Approximate threshold of
hearing for continuous noise
10
63
125
250
NC-40
NC-30
NC-20
500 1000 2000 4000 8000
Octave band center frequency (Hz)
8
A-22
Center
1.5m
Microphone
8. Fresh air intake (Design guide)
1-way (2 series) Air Discharge Cassette Type
Caution
The fresh air shall be conditioned by a heat reclaim ventilator or similar.
Ensure the fresh air volume is determined so that mixed suction air and fresh air can maintain the
operating temperature.
*1.Recommended conditioned air temperature is 12 °C to 30 °C.
However, Make a fresh air volume within 20% of standard.
Model name
Standard air flow
MMU(m3/h)
AP0152SH
750
AP0182SH
780
AP0242SH
1140
Install a filter within the fresh air duct.
(Fresh air does not pass through the filter of Indoor unit.)
Insulate the fresh air duct.
Electrically connect the fan of the Heat exchanger unit and the Indoor unit to a single isolator.
80
70
Static Pressure (Pa)
MMU-AP0152SH,MMU-AP182SH
60
50
40
30
MMU-AP0242SH
20
10
0
0
50
100
150
200
250
Fresh Air Volume (m3/h)
Indoor unit
Duct fan
motor
Fresh Air Volume
Flange Option :TCB-FF101URE
Inter - lock circuit
Connect the driving relay of the duct fan(DC 12V) between 1 and 6 on the indoor P.C. board.
(Rated current of the relay for duct fan should be up to 75mA.)
After installation, carry out a trial operation to check that the duct fan of the indoor unit start/stop
simultaneously.
(Carry out the trial operation following the installation manual of the indoor unit.)
A-23
9
9. Units center of gravity
1-way (2 series) Air Discharge Cassette Type
Model name
X (mm)
Y (mm)
Z (mm)
370
475
80
MMU-AP0152SH
MMU-AP0182SH
MMU-AP0242SH
10
A-24
Weight (kg)
Main unit
Ceiling panel
20
5.5
21
5.5
Oct. 05’
Engineering Data
Slim Duct Type
Indoor Unit
MMD-AP0071SPH
MMD-AP0091SPH
MMD-AP0121SPH
MMD-AP0151SPH
MMD-AP0181SPH
MMD-AP0071SPH (SH)-C
MMD-AP0091SPH (SH)-C
MMD-AP0121SPH (SH)-C
MMD-AP0151SPH (SH)-C
MMD-AP0181SPH (SH)-C
MMD-AP0071SPH-K
MMD-AP0091SPH-K
MMD-AP0121SPH-K
MMD-AP0151SPH-K
MMD-AP0181SPH-K
Contents
1.
2.
3.
4.
5.
6.
7.
8.
Specifications
Electrical current characteristics
Dimensions
Sensible capacity table
Wiring diagrams
Fan characteristics
Sound characteristics (NC Curve)
Fresh air intake (Design guide)
A-25
A-26
1. Specification
50Hz
Model name
MMD- AP0071SPH AP0091SPH AP0121SPH AP0151SPH
Cooling/Heating capacity
(kW)
2.2/2.5
2.8/3.2
3.6/4.0
4.5/5.0
Electrical
1 phase 50Hz 230V (220-240V)
Power supply
characteristics
Running current
(A)
0.29
0.29
0.31
0.32
Power consumption (kW)
0.039
0.039
0.043
0.045
Starting current
(A)
0.51
0.51
0.54
0.56
Appearance
Zinc hot dipping steel plate
Dimension
Height
(mm)
210
Width
(mm)
845
Depth
(mm)
645
Total weight
(kg)
22
22
22
23
Heat exchanger
Soundproof / Heat-insulating material
Fan
High
Standard air
(Mid./Low)
flow
Motor
External static pressure
(m3/h)
(m3/h)
(W)
(Pa)
Air filter pressure loss (Pa)
Controller
Air filter
Connecting
pipe
Gas pipe
(mm)
Liquid pipe
(mm)
Drain pipe (Nominal dia.mm)
(dB(A))
Sound pressure level Under air inlet
(dB(A))
High/Mid./Low Back air inlet
Sound power level
(dB(A))
AP0181SPH
5.6/6.3
0.39
0.054
0.68
23
Finned tube
Polyethylene foam + Polyurethane foam
Centrifugal fan (Sirocco fan)
540
600
690
780
470/400
520/450
600/520
680/580
60
6 (Factory setting)
5 (Factory setting)
4 (Factory setting)
-16-31-46 4steps
-15-30-45 4steps
-14-29-44 4steps
4
5
6
Remote controller
Standard filter supplied (Long life filter)
9.5
12.7
6.4
25 (Polyvinyl chloride tube : External dia.32 Internal dia.25)
36/33/30
38/35/32
39/36/33
40/38/36
28/26/24
29/27/25
32/30/28
33/3129
51
53
54
55
* This sound pressure level is measured on the condition of Factory setting external static pressure.
* This sound pressure level are measured in an anechoic chamber in accordance with JIS B8616.
A-27
1
1. Specification
60Hz
Model name
MMD- AP0071SPH AP0091SPH AP0121SPH AP0151SPH
Cooling/Heating capacity
(kW)
2.2/2.5
2.8/3.2
3.6/4.0
4.5/5.0
Electrical
Power supply
1 phase 60Hz 220V
characteristics
Running current
(A)
0.27
0.27
0.30
0.31
Power consumption (kW)
0.037
0.037
0.041
0.043
Starting current
(A)
0.47
0.47
0.53
0.54
Appearance
Zinc hot dipping steel plate
Dimension
Height
(mm)
210
Width
(mm)
845
Depth
(mm)
645
Total weight
(kg)
22
22
22
23
Heat exchanger
Soundproof / Heat-insulating material
Fan
High
Standard air
(Mid./Low)
flow
Motor
External static pressure
(m3/h)
(m3/h)
(W)
(Pa)
Air filter pressure loss (Pa)
Controller
Air filter
Connecting
pipe
Gas pipe
(mm)
Liquid pipe
(mm)
Drain pipe (Nominal dia.mm)
Sound pressure level Under air inlet
(dB(A))
High/Mid./Low Back air inlet
(dB(A))
Sound power level
(dB(A))
AP0181SPH
5.6/6.3
0.37
0.052
0.65
23
Finned tube
Polyethylene foam + Polyurethane foam
Centrifugal fan (Sirocco fan)
540
600
690
780
470/400
520/450
600/520
680/580
60
6 (Factory setting)
5 (Factory setting)
4 (Factory setting)
-16-31-46 4steps
-15-30-45 4steps
-14-29-44 4steps
4
5
6
Remote controller
Standard filter supplied (Long life filter)
9.5
12.7
6.4
25 (Polyvinyl chloride tube : External dia.32 Internal dia.25)
36/33/30
38/35/32
39/36/33
40/38/36
28/26/24
29/27/25
32/30/28
33/31/29
51
53
54
55
* This sound pressure level is measured on the condition of Factory setting external static pressure.
* This sound pressure level are measured in an anechoic chamber in accordance with JIS B8616.
2
A-28
1. Specification
China Model
Model name
MMD- AP0071SPH-C AP0091SPH-C AP0121SPH-C AP0151SPH-C AP0181SPH-C
Cooling/Heating capacity
(kW)
2.2/2.5
2.8/3.2
3.6/4.0
4.5/5.0
5.6/6.3
Electrical
Power supply
1 phase 50Hz 220V
characteristics
Running current
(A)
0.29
0.29
0.31
0.32
0.39
Power consumption (kW)
0.039
0.039
0.043
0.045
0.054
Starting current
(A)
0.51
0.51
0.54
0.56
0.68
Appearance
Zinc hot dipping steel plate
Dimension
Height
(mm)
210
Width
(mm)
845
Depth
(mm)
645
Total weight
(kg)
22
22
22
23
23
Heat exchanger
Finned tube
Soundproof / Heat-insulating material
Polyethylene foam + Polyurethane foam
Fan
Centrifugal fan (Sirocco fan)
3
High
(m /h)
Standard air
540
600
690
780
(Mid./Low)
(m3/h)
flow
470/400
520/450
600/520
680/580
Motor
External static pressure
Controller
Air filter
Connecting
Gas pipe
pipe
Liquid pipe
(W)
(Pa)
(mm)
(mm)
Drain pipe (Nominal dia.mm)
Sound pressure level Under air inlet
(dB(A))
High/Mid./Low Back air inlet
(dB(A))
60
10(factory setting)-20-35-50 4steps
Remote controller
Field supply
9.5
12.7
6.4
25 (Polyvinyl chloride tube : External dia.32 Internal dia.25)
36/33/30
38/35/32
39/36/33
40/38/36
28/26/24
29/27/25
32/30/28
33/31/29
* This sound pressure level is measured on the condition of Factory setting external static pressure.
* This sound pressure level are measured in an anechoic chamber in accordance with JIS B8616.
A-29
3
1. Specification
China Model
Model name
MMD- AP0071SH-C P0091SH-C AP0121SH-C AP0151SH-C
Cooling/Heating capacity
(kW)
2.2/2.5
2.8/3.2
3.6/4.0
4.5/5.0
Electrical
1 phase 50Hz 220V
Power supply
characteristics
Running current
(A)
0.26
0.26
0.27
0.28
Power consumption (kW)
0.027
0.027
0.031
0.033
Starting current
(A)
0.46
0.46
0.47
0.49
Appearance
Zinc hot dipping steel plate
Dimension
Height
(mm)
210
Width
(mm)
845
Depth
(mm)
645
Total weight
(kg)
22
22
22
23
Heat exchanger
Soundproof / Heat-insulating material
Fan
High
Standard air
(Mid./Low)
flow
Motor
External static pressure
Controller
Air filter
Connecting
Gas pipe
pipe
Liquid pipe
(m3/h)
(m3/h)
(W)
(Pa)
(mm)
(mm)
Drain pipe (Nominal dia.mm)
Sound pressure level Under air inlet
(dB(A))
High/Mid./Low Back air inlet
(dB(A))
4
A-30
AP0181SH-C
5.6/6.3
0.35
0.042
0.61
23
Finned tube
Polyethylene foam + Polyurethane foam
Centrifugal fan (Sirocco fan)
540
600
690
780
470/400
520/450
600/520
680/580
60
10(factory setting)-20-35-50 4steps
Remote controller
Field supply
9.5
12.7
6.4
20 (Polyvinyl chloride tube : External dia.26 Internal dia.20)
36/33/30
38/35/32
39/36/33
40/38/36
28/26/24
29/27/25
32/30/28
33/31/29
1. Specification
60Hz
Model name
MMD- AP0071SPH-K AP0091SPH-K AP0121SPH-K AP0151SPH-K
Cooling/Heating capacity
(kW)
2.2/2.5
2.8/3.2
3.6/4.0
4.5/5.0
Electrical
1 phase 60Hz 220V
Power supply
characteristics
Running current
(A)
0.27
0.27
0.30
0.31
Power consumption (kW)
0.037
0.037
0.041
0.043
Starting current
(A)
0.47
0.47
0.53
0.54
Appearance
Zinc hot dipping steel plate
Dimension
Height
(mm)
210
Width
(mm)
845
Depth
(mm)
645
Total weight
(kg)
22
22
22
23
Heat exchanger
Soundproof / Heat-insulating material
Fan
High
Standard air
(Mid./Low)
flow
Motor
External static pressure
(m3/h)
(m3/h)
(W)
(Pa)
Air filter pressure loss (Pa)
Controller
Air filter
Connecting
pipe
Gas pipe
(mm)
Liquid pipe
(mm)
Drain pipe (Nominal dia.mm)
(dB(A))
Sound pressure level Under air inlet
(dB(A))
High/Mid./Low Back air inlet
AP0181SPH-K
5.6/6.3
0.37
0.052
0.65
23
Finned tube
Polyethylene foam + Polyurethane foam
Centrifugal fan (Sirocco fan)
540
600
690
780
470/400
520/450
600/520
680/580
60
6 (Factory setting)
5 (Factory setting)
4 (Factory setting)
-16-31-46 4steps
-15-30-45 4steps
-14-29-44 4steps
4
5
6
Remote controller
Standard filter supplied (Long life filter)
9.5
12.7
6.4
25 (Polyvinyl chloride tube : External dia.32 Internal dia.25)
36/33/30
38/35/32
39/36/33
40/38/36
28/26/24
29/27/25
32/30/28
33/31/29
* This sound pressure level is measured on the condition of Factory setting external static pressure.
* This sound pressure level are measured in an anechoic chamber in accordance with JIS B8616.
A-31
5
2. Electrical current characteristics
Type
6
A-32
Model
Nominal Voltage Voltage Range
(V-Ph-Hz)
Min
Max
230-1-50
198
264
230-1-50
198
264
230-1-50
198
264
230-1-50
198
264
230-1-50
198
264
Fan Motor
kW
FLA
0.060
0.35
0.060
0.35
0.060
0.37
0.060
0.38
0.060
0.47
Power Supply
MCA MOCP
0.44
15
0.44
15
0.47
15
0.48
15
0.59
15
S-MMS (50Hz)
MMD-AP0071SPH
MMD-AP0091SPH
MMD-AP0121SPH
MMD-AP0151SPH
MMD-AP0181SPH
S-MMS (60Hz)
MMD-AP0071SPH
MMD-AP0091SPH
MMD-AP0121SPH
MMD-AP0151SPH
MMD-AP0181SPH
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
198
198
198
198
198
264
264
264
264
264
0.060
0.060
0.060
0.060
0.060
0.32
0.32
0.36
0.37
0.44
0.41
0.41
0.45
0.47
0.56
15
15
15
15
15
S-HRM
MMD-AP0071SPH
MMD-AP0091SPH
MMD-AP0121SPH
MMD-AP0151SPH
MMD-AP0181SPH
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
198
198
198
198
198
264
264
264
264
264
0.060
0.060
0.060
0.060
0.060
0.35
0.35
0.37
0.38
0.47
0.44
0.44
0.47
0.48
0.59
15
15
15
15
15
3. Dimensions
MMD-AP0071SPH(-K), AP0091SPH(-K), AP0121SPH(-K), AP0151SPH(-K), AP0181SPH(-K)
210
21
21
803 (inside)
103
Air filter
Refrigerant piping
511
645
19
4-Ø4
67
20 21
168
(inside)
57
21
845
359
372
422
502
168
40
67
120
80
Ø9
2
31
805
80
59
33
163
910
Fresh air inlet
(Knock-out hole)
Drain-up port
Hanger plate
Air inlet connecting flange (Field supply)
100
266.5
100
805
12.5
286.8
41.5
8.2 or less
Underside
100
100
100
100
100
100
100
100
100
100
45.3
12.5
100
825
n=24 M5 (Ø4.2 mounting hole)
805
12.5
12.5
100
100
100
100
100
188.6
44.3
100
170
44.3
Rearside
Wired remote controller
RBC-AMT21E
RBC-AMT31E
Simple wired remote controller
RBC-AS21E
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E
TCB-AX21E2
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
825
n=22 M5 (Ø4.2 mounting hole)
A-33
7
3. Dimensions
Installation space
(length:mm)
5 or more
210
Air outlet
100 or more
Under air inlet
250 or more
Rear air inlet
5 or more
5 or more
210
210
235 or m
Air inlet
Ceiling
235 or more
Air intlet
235 or more
Ceiling
300 or more
50 or more
2500 or more
2500 or more
Floor surface
Floor surface
Service space
(length:mm)
Air outlet
50
50
645
945
Air filter
Service door (Ceiling opening)
645
645
945
Service door (Ceiling opening)
Air filter
745
745
945
8
A-34
3. Dimensions
21
MMD-AP007SPH-C, AP0091SPH-C, AP0121SPH-C, AP0151SPH-C, AP0181SPH-C,
MMD-AP0071SH-C, AP0091SH-C, AP0121SH-C, AP0151SH-C, AP0181SH-C
210
803 (inside)
21
21
Natural drain port
103
Refrigerant
piping
80
511
645
19
359
372
422
502
805
910
59
40
168
67
80
146
31
120
Ø9
2
4-Ø4
67
20 21
168 (inside)
57
845
33
163
Fresh air inlet
(Knock-out hole)
Drain-up port
(SPH model only)
Hanger plate
Air inlet connecting flange (Field supply)
100
266.5
100
805
12.5
286.8
41.5
8.2 or less
Underside
100
100
100
100
100
100
100
100
100
100
45.3
12.5
100
825
n=24 M5 (Ø4.2 mounting hole)
Rearside
12.5
12.5
100
100
100
100
100
188.6
44.3
100
170
44.3
805
Wired remote controller
RBC-AMT21E
RBC-AMT31E
Simple wired remote controller
RBC-AS21E
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E
TCB-AX21E2
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
825
n=22 M5 (Ø4.2 mounting hole)
A-35
9
3. Dimensions
Installation space
(length:mm)
MMD-AP0071SPH-C, MMD-AP0091SPH-C, MMD-AP0121SPH-C, MMD-AP0151SPH-C, MMD-AP0181SPH-C
5 or more
235 or more
210
Air outlet
100 or more
250 or more
MMD-AP0071SH-C, MMD-AP0091SH-C, MMD-AP0121SH-C, MMD-AP0151SH-C, MMD-AP0181SH-C
Drain piping left side
Drain piping
5 or more
Air outlet
210
100 or more
235 or more
250 or more
Drain pipng right side
Drain piping
5 or more
Air outlet
210
250 or more
235 or more
200 or more
(Refrigerant piping space)
MMD-AP0071SPH-C, MMD-AP0091SPH-C, MMD-AP0121SPH-C, MMD-AP0151SPH-C, MMD-AP0181SPH-C
MMD-AP0071SH-C, MMD-AP0091SH-C, MMD-AP0121SH-C, MMD-AP0151SH-C, MMD-AP0181SH-C
Under air inlet
5 or more
210
235 or more
Air inlet
Ceiling
50 or more
2500 or more
Floor surface
Rear air inlet
5 or more
Air intlet
Ceiling
300 or more
2500 or more
Floor surface
10
A-36
210
235 or more
3. Dimensions
Service space
(length:mm)
MMD-AP0071SPH-C, MMD-AP0091SPH-C, MMD-AP0121SPH-C, MMD-AP0151SPH-C, MMD-AP0181SPH-C
Air outlet
50
50
945
645
Service door (Ceiling opening)
645
945
MMD-AP0071SH-C, MMD-AP0091SH-C, MMD-AP0121SH-C, MMD-AP0151SH-C, MMD-AP0181SH-C
Drain piping left side
Drain piping
Air outlet
50
100
645
995
Service door (Ceiling opening)
645
995
Drain pipng right side
Drain piping
Air outlet
100
50
995
645
Service door (Ceiling opening)
645
995
A-37
11
4. Sensible capacity table
Slim Duct Type ( MMD-AP***SPH )
14.0CWB
20CDB
TC
SHC
16.0CWB
23CDB
TC
SHC
TC : Total capacity [kW]
Indoor air temp.
18.0CWB
19.0CWB
20.0CWB
26CDB
27CDB
28CDB
TC
SHC
TC
SHC
TC
SHC
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.7
1.7
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.5
1.5
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
1.9
1.9
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.6
1.6
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.0
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.1
2.1
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.7
1.7
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.2
2.1
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.2
2.2
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.8
1.8
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.4
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
1.9
1.9
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.6
2.6
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.0
2.0
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.7
2.6
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.0
2.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
2.9
2.8
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.1
2.1
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.2
3.1
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.3
2.2
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.4
3.3
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.4
2.4
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.5
3.4
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.4
2.4
Unit Outdoor
size air temp.
CDB
007
009
012
12
A-38
SHC : Sensible capacity [kW]
22.0CWB
30CDB
TC
SHC
24.0CWB
32CDB
TC
SHC
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.7
1.7
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.3
2.3
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.7
1.7
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.4
2.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.6
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.8
2.7
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.0
2.0
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.0
2.9
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.0
2.0
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.1
3.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
1.9
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.6
3.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.4
2.4
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.8
3.7
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.4
2.3
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.0
3.9
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.3
2.3
4. Sensible capacity table
Slim Duct Type ( MMD-AP***SPH )
14.0CWB
20CDB
TC
SHC
16.0CWB
23CDB
TC
SHC
TC : Total capacity [kW]
Indoor air temp.
18.0CWB
19.0CWB
20.0CWB
26CDB
27CDB
28CDB
TC
SHC
TC
SHC
TC
SHC
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.6
3.5
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.7
2.7
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.0
3.8
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
2.9
2.8
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.2
4.1
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.1
3.0
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.4
4.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.1
3.0
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.5
4.4
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.6
4.5
4.3
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.3
3.3
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
4.9
4.8
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.6
3.5
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.3
5.1
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.8
3.7
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.4
5.3
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.8
3.7
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.6
5.4
Unit Outdoor
size air temp.
CDB
015
018
SHC : Sensible capacity [kW]
22.0CWB
30CDB
TC
SHC
24.0CWB
32CDB
TC
SHC
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.1
3.0
4.9
4.9
4.9
4.9
4.9
4.9
4.9
4.9
4.9
4.9
4.9
4.9
4.9
4.9
4.7
4.6
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.1
3.0
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.0
4.8
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.0
2.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.8
3.7
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
5.9
5.7
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.7
3.6
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.2
6.0
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.7
3.6
A-39
13
5. Wiring diagrams
MMD-AP0071SPH(SH), AP0091SPH(SH), AP0121SPH(SH), AP0151SPH(SH), AP0181SPH(SH)
14
A-40
6. Fan characteristics
MMD-AP0071SPH
MMD-AP0091SPH
MMD-AP0121SPH
Standard air volume : 540m3/h
Standard air volume : 600m3/h
60
60
High (50Pa)
50
Upper limit of
external static
pressure(35Pa)
High (35Pa)
40
Lower limit of external
static pressure (50Pa)
Low (50Pa)
Upper limit of
external static
pressure(20Pa)
30
High (20Pa)
Upper limit of
external static
pressure(10Pa)
20
Low (35Pa)
External static pressure (Pa)
50
External static pressure (Pa)
High (50Pa)
Upper limit of external
static pressure(50Pa)
Upper limit of external
static pressure(50Pa)
High (35Pa)
40
Low (50Pa)
Upper limit of
external static
pressure(20Pa)
20
Low (20Pa)
10
Upper limit of
external static
pressure(10Pa)
Lower limit of external
static pressure (20Pa)
Low (10Pa)
400
500
600
Lower limit of external
static pressure (35Pa)
High (10Pa)
High (10Pa)
Low (20Pa)
0
300
High (20Pa)
Low (35Pa)
Lower limit of external
static pressure (35Pa)
10
Lower limit of external
static pressure (50Pa)
Upper limit of
external static
pressure(35Pa)
30
700
0
300
Lower limit of external
static pressure (20Pa)
Low (10Pa)
400
500
600
700
Air Volume (m3/h)
Air Volume (m3/h)
MMD-AP0151SPH
MMD-AP0181SPH
Standard air volume : 690m3/h
Standard air volume : 780m3/h
60
60
High (50Pa)
High (50Pa)
Upper limit of external
static pressure(50Pa)
50
Upper limit of
external static
pressure(35Pa)
40
Lower limit of external
static pressure (50Pa)
Low (50Pa)
30
High (20Pa)
20
10
Low (35Pa)
Upper limit of
external static
pressure(20Pa)
Upper limit of
external static
pressure(10Pa)
0
400
500
Upper limit of external
static pressure(50Pa)
High (35Pa)
Lower limit of external
static pressure (35Pa)
External static pressure (Pa)
External static pressure (Pa)
50
High (35Pa)
40
Low (50Pa)
30
20
10
Low (20Pa)
Lower limit of external
static pressure (20Pa)
600
Air Volume (m3/h)
700
800
High (20Pa)
Low (35Pa)
High (10Pa)
Low (10Pa)
Lower limit of
external static
pressure (50Pa)
Upper limit of
external static
pressure(35Pa)
Upper limit of
external static
pressure(20Pa)
Lower limit of
external static
pressure (35Pa)
Upper limit of
external static
pressure(10Pa)
Low (20Pa)
Low (10Pa)
0
400
500
High (10Pa)
600
700
800
Lower limit of
external static
pressure (20Pa)
900
Air Volume (m3/h)
A-41
15
6. Fan characteristics
(Filter attached)
MMD-AP0071SPH
MMD-AP0091SPH
MMD-AP0121SPH
Standard air volume : 540m3/h
Standard air volume : 600m3/h
60
60
High (50Pa)
High (50Pa)
Upper limit of external
static pressure(50Pa)
50
50
Lower limit of external
static pressure (50Pa)
Upper limit of external
static pressure(50Pa)
Lower limit of externa
static pressure (50Pa)
Upper limit of
external static
pressure(35Pa)
30
Low (50Pa)
Lower limit of external
static pressure (35Pa)
Low (35Pa)
20
High (20Pa)
Upper limit of
external static
pressure(20Pa)
External static pressure (Pa)
External static pressure (Pa)
Low (50Pa)
40
40
Upper limit o
external static
pressure(35Pa)
30
Low (35Pa)
20
Upper limit o
external static
pressure(20Pa)
High (20Pa)
Lower limit of external
static pressure (20Pa)
Lower limit of extern
static pressure (20Pa)
Low (20Pa)
Low (20Pa)
10
10
Upper limit of
external static
pressure(10Pa)
High (10Pa)
Upper limit o
external static
pressure(10Pa)
High (10Pa)
Standard filter
pressure loss
Low (10Pa)
0
300
Lower limit of external
static pressure (35Pa)
High (35Pa)
400
500
600
Standard filter
pressure loss
Low (10Pa)
0
300
700
400
Air Volume (m3/h)
500
600
700
Air Volume (m3/h)
MMD-AP0151SPH
MMD-AP0181SPH
Standard air volume : 690m3/h
Standard air volume : 780m3/h
60
60
High (50Pa)
High (50Pa)
Upper limit of external
static pressure(50Pa)
Upper limit of external
static pressure(50Pa)
50
50
Lower limit of external
static pressure (50Pa)
Upper limit of external
static pressure(35Pa)
Lower limit of
external static
pressure (50Pa)
Upper limit of external
static pressure(35Pa)
Lower limit of external
static pressure (35Pa)
Low (50Pa)
30
Upper limit of
external static
pressure(20Pa)
High (20Pa)
Low (35Pa)
20
High (10Pa)
10
Upper limit of
external static
pressure(10Pa)
External static pressure (Pa)
External static pressure (Pa)
High (35Pa)
40
40
Low (50Pa)
Low (35Pa)
20
Upper limit of external
static pressure(20Pa)
Lower limit of externa
static pressure (20Pa)
Low (20Pa)
Lower limit of
external static
pressure (35Pa)
High (35Pa)
30
10
High (20Pa)
Lower limit of
external static
pressure (20Pa)
Upper limit of
external static
pressure(10Pa)
High (10Pa)
Low (20Pa)
Low (10Pa)
0
400
Standard filter
pressure loss
500
600
Air Volume (m3/h)
16
A-42
700
800
0
400
Standard filter
pressure loss
Low (10Pa)
500
600
700
Air Volume (m3/h)
800
900
6. Fan characteristics
CHINA model (Filter attached)
MMD-AP0071SPH-C, SH-C
MMD-AP0091SPH-C, SH-C
MMD-AP0121SPH-C, SH-C
Standard air volume : 540m3/h
Standard air volume : 600m3/h
60
60
High (50Pa)
Upper limit of external
static pressure(50Pa)
High (50Pa)
50
50
Upper limit of external
static pressure(50Pa)
High (35Pa)
40
High (35Pa)
Lower limit of external
static pressure (50Pa)
Low (50Pa)
Upper limit of
external static
pressure(35Pa)
30
High (20Pa)
20
Upper limit of
external static
pressure(20Pa)
Low (35Pa)
External static pressure (Pa)
External static pressure (Pa)
Upper limit of
external static
pressure(35Pa)
40
Low (50Pa)
30
Upper limit of
external static
pressure(35Pa)
20
Upper limit of
external static
pressure(20Pa)
Lower limit of external
static pressure (50Pa)
High (20Pa)
Low (35Pa)
Lower limit of external
static pressure (35Pa)
Lower limit of external
static pressure (35Pa)
Low (20Pa)
High (10Pa)
10
10
High (10Pa)
Low (20Pa)
Upper limit of
external static
pressure(10Pa)
0
300
Lower limit of external
static pressure (20Pa)
Low (10Pa)
400
500
600
Lower limit of external
static pressure (20Pa)
Upper limit of external
static pressure(10Pa)
0
300
700
Low (10Pa)
400
500
600
MMD-AP0151SPH-C, SH-C
MMD-AP0181SPH-C, SH-C
Standard air volume : 780m3/h
Standard air volume : 690m3/h
60
60
High (50Pa)
Upper limit of external
static pressure(50Pa)
High (50Pa)
Upper limit of external
static pressure(50Pa)
50
50
Upper limit of external
static pressure(35Pa)
Upper limit of external
static pressure(35Pa)
40
Low (50Pa)
Lower limit of external
static pressure (50Pa)
30
High (20Pa)
20
Lower limit of extern
static pressure (35Pa)
Low (35Pa)
High (35Pa)
40
Low (50Pa)
Lower limit of
external static
pressure (50Pa)
30
Low (35Pa)
20
Upper limit of external
static pressure(20Pa)
High (20Pa)
Lower limit of extern
static pressure (35Pa)
High (10Pa)
Upper limit of
external static
pressure(20Pa)
500
Low (20Pa)
Lower limit of external
static pressure (20Pa)
600
700
800
Lower limit of exte
static pressure (20Pa)
Upper limit of external
static pressure(10Pa)
Low (10Pa)
Air Volume (m3/h)
High (10Pa)
10
Low (20Pa)
Upper limit of
external static
pressure(10Pa)
0
400
External static pressure (Pa)
External static pressure (Pa)
High (35Pa)
10
700
Air Volume (m3/h)
Air Volume (m3/h)
0
400
500
Low (10Pa)
600
700
800
900
Air Volume (m3/h)
A-43
17
7. Sound Characteristics (NC Curve)
MMD-AP0071SPH/SH ,
MMD-AP0091SPH/SH
Measuring location
2m
1m
Duct
Duct
Air outlet
Rear air intake
Air inlet
Center
1.5m
Microphone
External static pressure 10Pa
H
M
L
28
26
24
Fan tap
Sound pressure
level (dB(A))
70
70
60
60
50
NC-50
40
NC-40
30
NC-30
H
M
20
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
Fan tap
Sound pressure
level (dB(A))
External static pressure 20Pa
L
29
27
25
50
NC-50
40
NC-40
30
NC-30
H
M
NC-20
L
NC-20
Approximate threshold of
hearing for continuous noise
Approximate threshold of
hearing for continuous noise
10
10
63
125
250
500
1000
2000
4000
63
8000
125
External static pressure 35Pa
Fan tap
Sound pressure
level (dB(A))
500
1000
2000
4000
8000
External static pressure 50Pa
H
M
L
30
28
26
Fan tap
Sound pressure
level (dB(A))
70
60
60
50
NC-50
40
NC-40
30
NC-30
H
M
L
Octave band sound pressure level (dB)
70
20
250
Octave band center frequency (Hz)
Octave band center frequency (Hz)
Octave band sound pressure level (dB)
M
20
L
H
M
L
32
29
27
50
NC-50
40
NC-40
H
30
NC-30
M
L
20
NC-20
NC-20
Approximate threshold of
hearing for continuous noise
Approximate threshold of
hearing for continuous noise
10
10
63
125
250
500
1000
2000
Octave band center frequency (Hz)
18
A-44
H
4000
8000
63
125
250
500
1000
2000
Octave band center frequency (Hz)
4000
8000
7. Sound Characteristics (NC Curve)
MMD-AP0121SPH/SH
Measuring location
2m
1m
Duct
Duct
Air outlet
Rear air intake
Air inlet
Center
1.5m
Microphone
External static pressure 10Pa
H
M
L
29
27
25
Fan tap
Sound pressure
level (dB(A))
70
70
60
60
50
NC-50
40
NC-40
30
H
NC-30
M
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
Fan tap
Sound pressure
level (dB(A))
External static pressure 20Pa
L
20
H
M
L
30
28
26
50
NC-50
40
NC-40
H
30
NC-30
M
L
20
NC-20
NC-20
Approximate threshold of
hearing for continuous noise
Approximate threshold of
hearing for continuous noise
10
10
63
125
250
500
1000
2000
4000
8000
63
125
Octave band center frequency (Hz)
External static pressure 35Pa
M
L
31
29
27
Fan tap
Sound pressure
level (dB(A))
70
70
60
60
50
NC-50
40
NC-40
H
30
500
1000
2000
4000
8000
External static pressure 50Pa
H
NC-30
M
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
Fan tap
Sound pressure
level (dB(A))
250
Octave band center frequency (Hz)
H
M
L
32
30
28
50
NC-50
40
NC-40
H
30
NC-30
M
L
L
20
20
NC-20
NC-20
Approximate threshold of
hearing for continuous noise
Approximate threshold of
hearing for continuous noise
10
10
63
125
250
500
1000
2000
Octave band center frequency (Hz)
4000
8000
63
125
250
500
1000
2000
4000
8000
Octave band center frequency (Hz)
A-45
19
7. Sound Characteristics (NC Curve)
MMD-AP0151SPH/SH
Measuring location
2m
1m
Duct
Duct
Air outlet
Rear air intake
Air inlet
Center
1.5m
Microphone
External static pressure 10Pa
External static pressure 20Pa
H
M
L
32
30
28
Fan tap
Sound pressure
level (dB(A))
70
70
60
60
50
NC-50
40
NC-40
30
H
NC-30
M
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
Fan tap
Sound pressure
level (dB(A))
L
33
31
29
50
NC-50
40
NC-40
30
M
L
NC-20
Approximate threshold of
hearing for continuous noise
Approximate threshold of
hearing for continuous noise
10
63
125
250
500
1000
2000
4000
10
8000
63
125
Octave band center frequency (Hz)
500
M
L
34
32
30
Fan tap
Sound pressure
level (dB(A))
70
60
60
50
NC-50
40
NC-40
H
NC-30
M
Octave band sound pressure level (dB)
70
M
L
35
33
31
NC-50
40
NC-40
H
30
500
NC-30
M
20
NC-20
Approximate threshold of
hearing for continuous noise
10
250
8000
50
Approximate threshold of
hearing for continuous noise
125
4000
L
NC-20
63
2000
H
L
20
1000
External static pressure 50Pa
H
30
250
Octave band center frequency (Hz)
External static pressure 35Pa
Fan tap
Sound pressure
level (dB(A))
NC-30
H
20
NC-20
Octave band sound pressur level (dB)
M
L
20
1000
2000
Octave band center frequency (Hz)
20
A-46
H
4000
8000
10
63
125
250
500
1000
2000
Octave band center frequency (Hz)
4000
8000
7. Sound Characteristics (NC Curve)
MMD-AP0181SPH/SH
Measuring location
2m
1m
Duct
Duct
Air outlet
Rear air intake
Air inlet
Center
1.5m
Microphone
External static pressure 10Pa
H
M
L
33
31
29
Fan tap
Sound pressure
level (dB(A))
70
70
60
60
50
NC-50
40
NC-40
H
30
NC-30
M
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
Fan tap
Sound pressure
level (dB(A))
External static pressure 20Pa
H
M
L
34
32
30
50
NC-50
40
NC-40
H
30
M
L
NC-30
L
20
20
NC-20
NC-20
Approximate threshold of
hearing for continuous noise
Approximate threshold of
hearing for continuous noise
10
10
63
125
250
500
1000
2000
4000
8000
63
125
Octave band center frequency (Hz)
External static pressure 35Pa
500
1000
2000
4000
8000
External static pressure 50Pa
H
M
L
35
33
31
Fan tap
Sound pressure
level (dB(A))
70
70
60
60
50
NC-50
40
NC-40
H
30
NC-30
M
L
20
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
Fan tap
Sound pressure
level (dB(A))
250
Octave band center frequency (Hz)
H
M
L
36
34
32
50
NC-50
40
NC-40
H
30
NC-30
M
L
20
NC-20
NC-20
Approximate threshold of
hearing for continuous noise
Approximate threshold of
hearing for continuous noise
10
10
63
125
250
500
1000
2000
Octave band center fequency (Hz)
4000
8000
63
125
250
500
1000
2000
4000
8000
Octave band center frequency (Hz)
A-47
21
7. Sound Characteristics (NC Curve)
MMD-AP0071SPH/SH ,
MMD-AP0091SPH/SH
2m
Duct
Air outlet
Measuring location
Center
1.5m
Under air intake
Air inlet
Microphone
External static pressure 10Pa
H
M
L
36
33
30
Fan tap
Sound pressure
level (dB(A))
70
70
60
60
50
NC-50
40
NC-40
H
M
30
NC-30
L
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
Fan tap
Sound pressure
level (dB(A))
External static pressure 20Pa
20
H
M
L
37
34
31
50
NC-50
40
NC-40
H
M
30
NC-30
L
20
NC-20
NC-20
Approximate threshold of
hearing for continuous noise
Approximate threshold of
hearing for continuous noise
10
10
63
125
250
500
1000
2000
4000
8000
63
125
Octave band center frequency (Hz)
External static pressure 35Pa
M
L
39
36
33
Fan tap
Sound pressure
level (dB(A))
70
70
60
60
50
NC-50
40
NC-40
H
M
30
500
1000
2000
NC-30
L
20
8000
H
M
L
41
38
35
50
NC-50
H
M
40
NC-40
L
30
NC-30
20
NC-20
NC-20
Approximate threshold of
hearing for continuous noise
Approximate threshold of
hearing for continuous noise
10
10
63
125
250
500
1000
2000
Octave band center frequency (Hz)
22
A-48
4000
External static pressure 50Pa
H
Octave band sound pressure level (dB)
Octave band soune pressure level (dB)
Fan tap
Sound pressure
level (dB(A))
250
Octave band center frequency (Hz)
4000
8000
63
125
250
500
1000
2000
Octave band center frequency (Hz)
4000
8000
7. Sound Characteristics (NC Curve)
2m
MMD-AP0121SPH/SH
Measuring location
Duct
Air outlet
Under air intake
Center
1.5m
Air inlet
Microphone
External static pressure 20Pa
External static pressure 10Pa
Fan tap
Sound pressure
level (dB(A))
H
M
L
38
35
32
Fan tap
Sound pressure
level (dB(A))
70
L
39
36
33
60
50
NC-50
40
NC-40
H
M
30
NC-30
L
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
M
70
60
20
50
NC-50
40
M
30
NC-20
Approximate threshold of
hearing for continuous noise
10
125
250
500
1000
2000
4000
10
8000
63
125
Octave band center frequency (Hz)
M
L
41
38
35
Fan tap
Sound pressure
level (dB(A))
70
60
60
50
NC-50
H
NC-40
M
L
NC-30
20
NC-20
Octave band sound pressure frequency (dB)
70
30
250
2000
4000
8000
H
M
L
43
40
37
NC-50
H
40
NC-40
M
L
30
NC-30
20
NC-20
Approximate threshold of
hearing for continuous noise
10
125
1000
50
Approximate threshold of
hearing for continuous noise
63
500
External static pressure 50Pa
H
40
250
Octave band center frequency (Hz)
External static pressure 35Pa
Fan tap
Sound pressure
level (dB(A))
NC-30
L
20
NC-20
63
NC-40
H
Approximate threshold of
hearing for continuous noise
Octave band sound pressure level (dB)
H
500
1000
2000
Octave band center frequency (Hz)
4000
8000
10
63
125
250
500
1000
2000
4000
8000
Octave band center frequency (Hz)
A-49
23
7. Sound Characteristics (NC Curve)
MMD-AP0151SPH/SH
2m
Measuring location
Duct
Air outlet
Under air intake
Center
1.5m
Air inlet
Microphone
External static pressure 10Pa
H
M
L
39
36
33
Fan tap
Sound pressure
level (dB(A))
70
70
60
60
50
NC-50
40
NC-40
H
M
30
NC-30
L
Octave band sound frequency level (dB)
Octave band sound pressure level (dB)
Fan tap
Sound pressure
level (dB(A))
External static pressure 20Pa
20
H
M
L
40
37
34
50
NC-50
40
NC-40
H
M
30
NC-30
L
20
NC-20
NC-20
Approximate threshold of
hearing for continuous noise
Approximate threshold of
hearing for continuous noise
10
10
63
125
250
500
1000
2000
4000
8000
63
125
External static pressure 35Pa
M
L
41
38
35
Fan tap
Sound pressure
level (dB(A))
70
70
60
60
50
NC-50
H
40
NC-40
M
L
30
500
1000
2000
NC-30
20
8000
H
M
L
43
40
37
50
NC-50
H
40
NC-40
M
L
30
NC-30
20
NC-20
NC-20
Approximate threshold of
hearing for continuous noise
Approximate threshold of
hearing for continuous noise
10
10
63
125
250
500
1000
2000
Octave band center frequency (Hz)
24
A-50
4000
External static pressure 50Pa
H
Octave band sound frequency level (dB)
Octave band sound pressure level (dB)
Fan tap
Sound pressure
level (dB(A))
250
Octave band center frequency (Hz)
Octave band center frequency (Hz)
4000
8000
63
125
250
500
1000
2000
Octave band center frequency (Hz)
4000
8000
7. Sound Characteristics (NC Curve)
MMD-AP0181SPH/SH
2m
Measuring location
Duct
Air outlet
Under air intake
Center
1.5m
Air inlet
Microphone
External static pressure 10Pa
H
M
L
40
38
36
Fan tap
Sound pressure
level (dB(A))
70
70
60
60
50
NC-50
40
NC-40
H
M
30
NC-30
L
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
Fan tap
Sound pressure
level (dB(A))
External static pressure 20Pa
H
M
L
42
40
37
50
NC-50
H
40
NC-40
M
L
30
NC-30
20
20
NC-20
NC-20
Approximate threshold of
hearing for continuous noise
Approximate threshold of
hearing for continuous noise
10
10
63
125
250
500
1000
2000
4000
63
8000
125
External static pressure 35Pa
500
1000
2000
4000
8000
External static pressure 50Pa
H
M
L
43
41
38
Fan tap
Sound pressure
level (dB(A))
70
70
60
60
50
NC-50
H
40
NC-40
M
L
30
NC-30
20
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
Fan tap
Sound pressure
level (dB(A))
250
Octave band center frequency (Hz)
Octave band center frequency (Hz)
H
M
L
44
42
39
50
NC-50
H
40
NC-40
M
L
30
NC-30
20
NC-20
NC-20
Approximate threshold of
hearing for continuous noise
Approximate threshold of
hearing for continuous noise
10
10
63
125
250
500
1000
2000
Octave band center frequency (Hz)
4000
8000
63
125
250
500
1000
2000
4000
8000
Octave band center frequency (Hz)
A-51
25
8. Fresh air intake (Design guide)
Slim Duct Type
MMD-AP0071SPH, AP0091SPH, AP0121SPH
MMD-AP0071SPH-C, AP0091SPH-C, AP0121SPH-C
MMD-AP0071SH-C, AP0091SH-C, AP0121SH-C
Caution
The fresh air shall be conditioned by heat reclaim ventilator or similar.
Ensure the fresh air volume is determined so that mixed suction air and fresh air maintain the
operating temperature.
*1.Recommended conditioned air temperature is 12 °C to 30 °C.
However, Make a fresh air volume within 20% of standard.
Model name
MMD-
Standard air flow
(m3/h)
AP0071SPH
AP0071SPH-C
AP0071SH-C
540
AP0091SPH
AP0091SPH-C
AP0091SH-C
540
AP0121SPH
AP0121SPH-C
AP0121SH-C
600
Install a air filter within the fresh air duct.
( Fresh air does not pass through the filter of Indoor unit.)
Insulate the fresh air duct.
Electrically connect the fan of the Heat exchanger unit and the Indoor unit to a single isolator.
Static Pressure (Pa)
30
20
10
0
-10
0
20
40
60
80
100
120
140
Fresh Air Volume (m3/h)
Indoor unit
Duct fan
motor
Fresh Air Volume
Flange Option :TCB-FF101URE
Inter - lock circuit
Connect the driving relay of the duct fan (DC 12V) between 1 and 6 on the indoor P.C. board.
(Rated current of the relay for duct fan should be up to 75mA.)
After installation, carry out a trial operation to check that the duct fan of the indoor unit start/stop
simultaneously.
(Carry out the trial operation following the installation manual of the indoor unit.)
26
A-52
8. Fresh air intake (Design guide)
Slim Duct Type
MMD-AP0151SPH, AP0181SPH
MMD-AP0151SPH-C, AP0181SPH-C
MMD-AP0151SH-C, AP0181SH-C
Caution
The fresh air shall be conditioned by heat reclaim ventilator or similar.
Ensure the fresh air volume is determined so that mixed suction air and fresh air maintain the
operating temperature.
*1.Recommended conditioned air temperature is 12 °C to 30 °C.
However, Make a fresh air volume within 20% of standard.
Model name
MMD-
Standard air flow
(m3/h)
AP0151SPH
AP0151SPH-C
AP0151SH-C
690
AP0181SPH
AP0181SPH-C
AP0181SH-C
780
Install a air filter within the fresh air duct.
( Fresh air does not pass through the filter of Indoor unit.)
Insulate the fresh air duct.
Electrically connect the fan of the Heat exchanger unit and the Indoor unit to a single isolator.
Static Pressure (Pa)
60
50
AP0151
40
30
20
AP0181
10
0
-10
0
20
40
60
80
100
120
140
160
180
Fresh Air Volume (m3/h)
Indoor unit
Duct fan
motor
Fresh Air Volume
Flange Option :TCB-FF101URE
Inter - lock circuit
Connect the driving relay of the duct fan (DC 12V) between 1 and 6 on the indoor P.C. board.
(Rated current of the relay for duct fan should be up to 75mA.)
After installation, carry out a trial operation to check that the duct fan of the indoor unit start/stop
simultaneously.
(Carry out the trial operation following the installation manual of the indoor unit.)
A-53
27