Download 9-4 -1 - Toshiba Air Conditioning

Transcript
Engineering Data Book
File No. E06-311
The engineering data book details all relevant data, charts and drawings to
enable you to get the best performance from the Toshiba Mini-SMMS for various
applications.
The information is aimed to assist you by providing greater system details and
the wider applications that system covers.
It is recommended that the data book be used in accordance with the following
as references.
Design manual: File No.A06-111
Installation manual: File No.A06-211
Service manual: File No.A05-016
1 -1
Contents
1.
Forward ...................................................................................................................... 1-1
2.
Contents .................................................................................................................... 2-1
3.
Introduction ............................................................................................................... 3-1
4.
System overview ....................................................................................................... 4-1
4-1.
Summary of system equipments ....................................................................... 4-1
4-2.
Outdoor units .................................................................................................... 4-2
4-3.
Indoor units ....................................................................................................... 4-3
4-4.
Branching joints and headers ........................................................................... 4-5
4-5.
PMV Kit ............................................................................................................. 4-5
4-6.
Remote controller ............................................................................................. 4-6
5.
Capacity compensation chart .................................................................................. 5-1
6.
Piping requirements ................................................................................................. 6-1
7.
Refrigerant cycle diagram ........................................................................................ 7-1
8.
Wiring guideline ........................................................................................................ 8-1
9.
Indoor unit line up ..................................................................................................... 9-1
9-1.
4-way Air Discharge Cassette Type ............................................................... 9-1-1
9-2.
Compact 4-way Cassette (600 × 600) Type ................................................... 9-2-1
9-3.
2-way Air Discharge Cassette Type ............................................................... 9-3-1
9-4.
1-way Air Discharge Cassette Type (Included NewType) .............................. 9-4-1
9-5.
Concealed Duct Standard Type ..................................................................... 9-5-1
9-6.
Slim Duct Type ............................................................................................... 9-6-1
9-7.
Concealed Duct High Static Pressure Type ................................................... 9-7-1
9-8.
Under Ceiling Type ........................................................................................ 9-8-1
9-9.
High Wall (1 series) Type ............................................................................... 9-9-1
9-10. High Wall (2 series) Type ............................................................................. 9-10-1
9-11. Floor Standing Cabinet Type ....................................................................... 9-11-1
9-12. Floor Standing Concealed Type .................................................................. 9-12-1
9-13. Floor Standing Type ..................................................................................... 9-13-1
9-14. Optional parts of indoor units ....................................................................... 9-14-1
10. PMV Kit .................................................................................................................... 10-1
11. Outdoor unit ............................................................................................................ 11-1
12. Controls ................................................................................................................... 12-1
2 -1
3
Mini-SMMS Data book
Introduction
Toshiba MiNi-SMMS Air Conditioning
Greater Flexibility for Even More Comfort
• Superior new Toshiba VRF system for small and mid-sized buildings
• Toshiba’s innovative spirit — concept of VRF, all advantages of SMMS
1
2
World’s best class energy savings
• World-class energy savings — COP of 4.61* achieved by Toshiba’s
unrivalled SMMS technologies and newly developed components
*4HP CDU system
Flexible and easy installation
• Greater application versatility—13 types of indoor units for use in up to 9
rooms; max. 6 HP
3
4
• Small and light weight outdoor unit
• Total piping length 180 m* (forthest 100 m)
• Maximum height variation for indoor units
(Outdoor unit is up to 30 m higher than indoor unit / outdoor unit is up to 20 m lower than indoor unit)
*150 m with PMV kit
Pursue unexpected quieter operation
• Quiet operation enables a tranquil interior environment, which can be
further enhanced with our optional PMV* kit
• Product made from quieter outdoor unit by adoption of Bat wing fan
*Pulse Motor Valve
5
6
7
8
9
10
11
12
3
-1
3 Introduction
1
World’s best class energy savings
World-class energy savings — COP of 4.61* achieved by Toshiba’s unrivalled
SMMS technologies and newly developed components
*4HP CDU system
2
New
New
New
Vector-controlled inverter
Vector IPDU control changes motor current
wave to a smooth sinusoidal pattern so that
noise emitted from the drive units is greatly
reduced.
• High output / high
efficiency DC motor
• 600W output
• Sine wave drive
3
4
DC fan motor
Efficient circuit built-in
and new PIM adoption
Heat exchanger
Smooth sign curve liquid
realizes efficient-izing and
low noise-ization.
High-efficiency R410A
heat-transfer tube
Configuration of the finned
heat-transfer tube
5
New
New
6
Twin-rotary DC compressor
Greater motor efficiency
from improved coil design
Bat wing fan
New development for high
pressure low sound fan
→ The bat wing fan realizes
the sound level equivalent
to current model.
7
Anti-eddy projection
Anti-eddy projection prevents
big eddies and reduces air
resistance.
Reverse-arc-shape wing
Reverse-arc-shape wing
reduces air resistance.
8
9
10
DC twin rotary compressor (A3 comp) features
High reliability
The enhanced DC twin-rotary compressor delivers stable performance with minimum friction:
Ideal for noise-sensitive applications. The outdoor unit is almost imperceptible.
TWIN-ROTARY COMPRESSOR
Comparison of DC twin rotary and Scroll compressor
• Low vibrations
• Super-quiet
operation
• High reliability
This difference is the
reason for actual energy
savings
Total efficiency of
compressor
Toshiba Twin-Rotary
Partial load range
*Most frequent operation
DC Twin
rotary type
Conventional
Scroll type
Traditional Compressor
Frequency of compressor
3
Nominal range
(%)
11
12
Higher refrigerant
compression from
redesigned
compression
channels
More effective
compression from
high-precision
components
-2
(rps)
3 Introduction
Expansive variety in our line-up of indoor units
Shortest route design by free branching
Combination of line and header branching is highly
flexible, allowing the shortest route possible thereby
saving on installation time and costs. Line/header
branching after header branching is only available
with TOSHIBA.
2
- Line branching
- Header branching
- Line + Header branching
Line branching after header branching
3
Outdoor unit
PMV-Kit
1
Header
Br anching joint
PMV kit
Indoor unit
Header branching after header branching
4
Outdoor unit
Header
Header
PMV kit
New compact 4-way
cassette
Indoor unit
6
Small and lightweight
Super-MMS outdoor unit
Mini-SMMS outdoor unit
228 kg
117 kg
3-phase
1-phase
Compact
1,800 mm
7
1,340 mm
Mini-SMMS is born from
our supreme VRF technology
990 mm
5
900 mm
320 mm
8
750 mm
9
Piping length
Best-in-class piping length and height
10
11
12
3
-3 (Revised edition in 7.Apr.2006)
3 Introduction
1
Bat Wing fan
Quieter with smoother wind flow
New bat
wing fan
2
3
Night operation mode
4
5
6
7
8
9
10
Quiet er sound
and
power saving
DC fan
motor
Mini-SMMS has timed, Night Operation, allowing
queter operation at night.
(A timer or a switch is local arrangements)
Day
Clears nighttime residential noise ordinances.
Can be used without obstructing peaceful
neighborhoods at night.
Night
Outdoor unit
Daytime
Night
4HP
49dB
46dB
5HP
50dB
46 dB
6HP
51dB
47dB
PMV kit
PMV kit (RBM-PMV0361E/RBMPMV0901E) shall be required for
quiter place application as an
optional to reduce refrigerant sound
especially in oil retrieval control or
in transient operation as start up.
Suppress particular-Hz noise away
Suppress overall noise levels
Die-away Zone
11
12
(Hz)
(Hz)
3
-4 (Revised edition in 7.Apr.2006)
4-1. Summary of system equipments
World-class energy savings _COP of 4.61* achieved by Toshiba’s unrivalled
S-MMS technologies and newly developed components
*4HP CDU system
Quiet operation can be further enhanced with an optional PMV
(flow regulating valve) Kit.
*Pulse Motor Valve
Versatile application _13 types of indoor units for use in up to 9 rooms (6 HP)
Sales launch scheduled for early 2006. Specifications differ by region.
For questions regarding availability, please contact your local distributor.
PMV Kit
New compact 4-way
cassette
Use of quieter place
Necessity of PMV Kit (RBM-PMV0361E / RBM-PMV0901E) for
quieter place application as an optional.
4 -1
4-2. Outdoor units
Inverter unit
Corresponding HP
Model
name
4HP
5HP
6HP
Heat pump(50Hz) MCY-
MAP0401HT
MAP0501HT
MAP0601HT
Heat pump(60Hz) MCY-
MAP0401HT2D
MAP0501HT2D
MAP0601HT2D
Cooling capacity(kW)*1
12.1
14.0
15.5
Heating capacity(kW)*1
12.5
16.0
18.0
6
8
9
No.of connectable indoor units
*1 Rated conditions
o
o
o
Cooling:Indoor air temperature 27 C DB/19 CWB,Outdoor air temperature 35 CDB
o
o
o
Heating:Indoor air temperature 20 C DB,Outdoor air temperature 7 CDB/6 CWB
Allocation standard of model name
MCY- M
AP
H
T
2D
No mark: Power supply specification, 1O/ 220-240V, 50Hz
2D
: Power supply specification, 1O/ 220V, 60Hz
T : Inverter unit
H : Heat pump
Development Number
Capacity rank HP x 10
R410A
M : Individual unit
Multi Compact Type
4 -2
4-3. Indoor units
Type
4-way Air Discharge
Cassette Type
Compact 4-way
Air Discharge
(600x600) Type
2-way Air Discharge
Cassette Type
1-way Air Discharge
Cassette Type
Concealed Duct
Standard Type
Slim Duct Type
Concealed Duct
High Static
Pressure Type
Under Ceilling Type
Appearance
Model name
Capacity rank
Capacity
code
Cooling
Heating
capacity (kW) capacity (kW)
PMV Kit
MMU-AP0091H
009 type
1.00
2.8
3.2
MMU-AP0121H
012 type
1.25
3.6
4.0
MMU-AP0151H
015 type
1.70
4.5
5.0
MMU-AP0181H
018 type
2.00
5.6
6.3
MMU-AP0241H
024 type
2.50
7.1
8.0
MMU-AP0271H
027 type
3.00
8.0
9.0
MMU-AP0301H
030 type
3.20
9.0
10.0
MMU-AP0361H
036 type
4.00
11.2
12.5
MMU-AP0481H
048 type
5.00
14.0
16.0
MMU-AP0071MH
007 type
0.80
2.2
2.5
Available
MMU-AP0091MH
009 type
1.00
2.8
3.2
Available
MMU-AP0121MH
012 type
1.25
3.6
4.0
Available
MMU-AP0151MH
015 type
1.70
4.5
5.0
Available
MMU-AP0181MH
018 type
2.00
5.6
6.3
Available
MMU-AP0071WH
007 type
0.80
2.2
2.5
MMU-AP0091WH
009 type
1.00
2.8
3.2
MMU-AP0121WH
012 type
1.25
3.6
4.0
MMU-AP0151WH
015 type
1.70
4.5
5.0
MMU-AP0181WH
018 type
2.00
5.6
6.3
MMU-AP0241WH
024 type
2.50
7.1
8.0
MMU-AP0271WH
027 type
3.00
8.0
9.0
MMU-AP0301WH
030 type
3.20
9.0
10.0
MMU-AP0071YH
007 type
0.80
2.2
2.5
Available
MMU-AP0091YH
009 type
1.00
2.8
3.2
Available
MMU-AP0121YH
012 type
1.25
3.6
4.0
Available
MMU-AP0152SH
015 type
1.70
4.5
5.0
Available
MMU-AP0182SH
018 type
2.00
5.6
6.3
Available
MMU-AP0242SH
024 type
2.50
7.1
8.0
Available
MMD-AP0071BH
007 type
0.80
2.2
2.5
MMD-AP0091BH
009 type
1.00
2.8
3.2
MMD-AP0121BH
012 type
1.25
3.6
4.0
MMD-AP0151BH
015 type
1.70
4.5
5.0
MMD-AP0181BH
018 type
2.00
5.6
6.3
MMD-AP0241BH
024 type
2.50
7.1
8.0
MMD-AP0271BH
027 type
3.00
8.0
9.0
MMD-AP0301BH
030 type
3.20
9.0
10.0
MMD-AP0361BH
036 type
4.00
11.2
12.5
MMD-AP0481BH
048 type
5.00
14.0
16.0
MMD-AP0071SPH
007 type
0.80
2.2
2.5
Available
MMD-AP0091SPH
009 type
1.00
2.8
3.2
Available
MMD-AP0121SPH
012 type
1.25
3.6
4.0
Available
MMD-AP0151SPH
015 type
1.70
4.5
5.0
Available
MMD-AP0181SPH
018 type
2.00
5.6
6.3
Available
MMD-AP0181H
018 type
2.00
5.6
6.3
MMD-AP0241H
024 type
2.50
7.1
8.0
MMD-AP0271H
027 type
3.00
8.0
9.0
MMD-AP0361H
036 type
4.00
11.2
10.0
MMD-AP0481H
048 type
5.00
14.0
16.0
MMC-AP0151H
015 type
1.70
4.5
5.0
MMC-AP0181H
018 type
2.00
5.6
6.3
MMC-AP0241H
024 type
2.50
7.1
8.0
MMC-AP0271H
027 type
3.00
8.0
9.0
MMC-AP0361H
036 type
4.00
11.2
12.5
MMC-AP0481H
048 type
5.00
14.0
16.0
4 -3
Type
Appearance
High Wall Type
(1 series)
High Wall Type
(2 series)
Floor Standing
Cabinet Type
Floor Standing
Concealed Type
Floor Standing Type
Cooling
Heating
capacity (kW) capacity (kW)
Capacity
rank
Capacity
code
MMK-AP0071H
007 type
0.80
2.2
2.5
Available
MMK-AP0091H
009 type
1.00
2.8
3.2
Available
MMK-AP0121H
012 type
1.25
3.6
4.0
Available
MMK-AP0151H
015 type
1.70
4.5
5.0
Available
MMK-AP0181H
018 type
2.00
5.6
6.3
Available
MMK-AP0241H
024 type
2.50
7.1
8.0
Available
MMK-AP0072H
007 type
0.80
2.2
2.5
Available
MMK-AP0092H
009 type
1.00
2.8
3.2
Available
MMK-AP0122H
012 type
1.25
3.6
4.0
Available
MML-AP0071H
007 type
0.80
2.2
2.5
Available
MML-AP0091H
009 type
1.00
2.8
3.2
Available
MML-AP0121H
012 type
1.25
3.6
4.0
Available
MML-AP0151H
015 type
1.70
4.5
5.0
Available
MML-AP0181H
018 type
2.00
5.6
6.3
Available
MML-AP0241H
024 type
2.50
7.1
8.0
Available
MML-AP0071BH
007 type
0.80
2.2
2.5
MML-AP0091BH
009 type
1.00
2.8
3.2
MML-AP0121BH
012 type
1.25
3.6
4.0
MML-AP0151BH
015 type
1.70
4.5
5.0
MML-AP0181BH
018 type
2.00
5.6
6.3
MML-AP0241BH
024 type
2.50
7.1
8.0
MMF-AP0151H
015 type
1.70
4.5
5.0
MMF-AP0181H
018 type
2.00
5.6
6.3
MMF-AP0241H
024 type
2.50
7.1
8.0
MMF-AP0271H
027 type
3.00
8.0
9.0
MMF-AP0361H
036 type
4.00
11.2
10.0
MMF-AP0481H
048 type
5.00
14.0
16.0
Model name
Allocation standard of model name
MM
-
AP
H
-
C : China model
M : Compact 4-way Cassete Type
W : 2-way Cassete Type
S : 1-way Cassete Type
Y : Small sized 1-way Cassete Type
B : Built-in Type (Built-in Duct Type)
(Floor concealed Type)
SP(S) : Slim Duct Type
Development series No.
Based on the cooling capacity (Btu/h)/1,000
R410A
U : Cassette Type
D : Duct Type
C : Under Ceiling Type
K : High Wall Type
L : Floor Type (Cabinet type)
(Concealed type)
F : Floor Standing Type
MM : Modular Multi Type
4 -4
PMV Kit
4-4. Branching joints and headers
Model name
*1
Usage
RBM-BY53E
Indoor unit capacity code (*2) :Total below 6.4
RBM-BY103E
Indoor unit capacity code (*2) :Total 6.4 or more
and below 7.8
Appearance
Y-shape branching joint
4-branching header
RBM-HY1043E Indoor unit capacity code (*2) :Total below 7.8
8-branching header
RBM-HY1083E Indoor unit capacity code (*2) :Total below 7.8
*1 If total capacity code value of indoor unit exceeds that of outdoor unit, apply code of outdoor unit.
*2 "capacity code" can be obtained from page~. (capacity code is not actual capacity)
*3 When using Y-shape branching joint for 1st branching, select according to the capacity code of outdoor unit.
4-5. PMV Kit
Model name
Indoor unit capacity type
RBM-PMV0361E
007, 009, 012 type
RBM-PMV0901E
015, 018, 024 type
For more information see Chapter 10.
4 -5
Appearance
4-6. Remote controller
Name Model
name
Appearance
Application
Connected to indoor unit
Function
Start / Stop
Mode Change
Temperature setting
Fan speed
Timer function
1
On or off elapsed timer
with 30 minite increments.
Automatic off function
Weekly when combined with
RBC-EXW21E2
weekly schedule operation can
be operated.
RBC-AMT31E
Wired remote controller
2
Filter dirty indicator
Displays automatically maintenance
time of indoor filter by flashes.
Self-diagnosis function
Wired remote
controller
Wired remote
controller
(In case of control
by 2 remote
controllers)
Pressing "CHECK" button
displays status code.
Control by 2 remote controllers is
available.
Two remote controllers can be
connected to one indoor unit.
The indoor unit can be separately
operated from a different location.
Connected to indoor unit
Start / Stop
Change of air flow
Check code display
RBC-AS21E2
Simple wired remote controller
Temperature setting
TEST
SETTING
ûC
ûF
Simple remote controller
4 -6
Model
Name name
Appearance
Function
Start / Stop
TCB-AX21U(W)-E2
Mode change
Temperature setting
Change of air flow
Timer function
On or off timer operation, setting in
30 minute increments.
Automatic Off function
available.
Two wireless remote controllers can
RBC-AX22CE2
operate one indoor unit. The indoor unit
can be separately operated from a
different location.
Check code display
TCB-AX21U(W)-E2
(for 4-way airdischarge cassette)
RBC-AX22CE2
(for under ceiling)
TCB-AX21-E2
(for other units except for the concealed duct high static pressure)
TCB-AX21E2
Wireless remote controller kit
Control by 2 remote controllers is
4 -7
Name
Model
name
Appearance
Application
Connected to outdoor unit,
or indoor unit
Outdoor
unit
Performance
Individual control up to 64 indoor units.
Individual control for max. 64 indoor
units divided into 4 zones.
Up to 16 indoor units for each
zone
Four selectable central control settings to
restrict individual remote controller
operations.
ZONE
ALL
ZONE
GROUP
CODE
No.
TCB-SC642TLE2
Central remote controller
Up to 16 outdoor units are
connectable.
1234
SET DATA
SETTING
R.C.
UNIT No.
TEST
Setting for one of 1 to 4 zones is
available.
No.
GROUP
SELECT
ZONE
Central
remote controller
CL
SET
Can be used with other central control
devices (Up to 10 central control
devices with in one control circuit)
Two selectable control modes
Central controller mode
Remote controller mode
Setting of simultaneous ON/OFF 3
times for each day of the week
combined with a weekly timer.
Central
remote
controller
Indoor
remote controller
Connected to outdoor unit,
or indoor unit
Individual control up to 16 indoor units.
Setting of simultaneous ON-OFF 3
times for each day of the week when
combined with a weekly timer.
Connected to 2 remote controllers is
possible.
TCB-CC163TLE2
ON-OFF controller
Outdoor unit
ON-OFF
controller
Indoor unit
ON-OFF
controller
Indoor
remote controller
4 -8
Name
Model
name
Appearance
Application
Performance
Weekly schedule operation
Connected to central
remote controller or
wired remote controller
1 Setting different start / stop time for each
day of the week
2 ON / OFF can be set 3 times
a day.
ON
8:00
OFF ON
OFF ON
OFF
12:00 13:00 18:00 19:00 21:00
3 "CHECK" "PROGRAM" "DAY"
RBC-EXW21E2
Weekly timer
Wired
remote controller
Weekly
timer
4 Two different schedules for a
week can be specified.
(Summer schedule and winter
schedule, etc.)
SuMoTuWeTh Fr Sa
PROGRAM1
PROGRAM2
button copying of settings easy.
ERROR
PROGRAM3
5 "CANCEL" "DAY" button enables
holiday setting.
WEEKLY TIMER
6 If power supply fails, the setting
Outdoor unit
Central
remote controller
4 -9
Weekly
timer
contents are stored in the memory for
100 hours.
1 For indoor unit, the capacity code is decided for each capacity rank.
Capacity rank type
007
009
012
015
018
024
027
030
036
048
Capacity code
0.8
1
1.25
1.7
2
2.5
3
3.2
4
5
NOTE :
Capacity rank : Correspondence to Btu/h.
Capacity code : Correspondence to Horsepower.
2 For outdoor unit, maximum No. of connectable indoor units and total capacity code of indoor units
are decided.
Outdoor unit
Capacity code of
outdoor unit
Max. No. of
indoor units
Total capacity code
of indoor units
4
6
3.2 to 5.2
5
8
4.0 to 6.5
6
9
4.8 to 7.8
MCY-MAP0401HT
MCY-MAP0401HT2D
MCY-MAP0501HT
MCY-MAP0501HT2D
MCY-MAP0601HT
MCY-MAP0601HT2D
5-1. Cooling/heating capacity characteristics
1 Cooling capacity calculation method :
Required cooling capacity = Cooling capacity x Factor ( , ,
1.1
1.0
0.9
0.8
15
20
24
*1) kW
,
(Example)
Design Indoor conditions : 22oC WB
Capacity correction value : 1.09
1.2
Capacity correction value
Capacity correction value
Indoor air wet bulb temperature vs. capacity correction value
,
1.2
1.1
1.0
0.9
0.8
15
20
24
Indoor air wet bulb temp. (oC)
o
Indoor air wet bulb temp. ( C)
1.2
1.1
1
0.9
-5
0
5
10
15
20
25
30
35
40 43
o
Capacity correction value
Capacity correction value
Outdoor air dry bulb temperature vs.capacity correction value
(Example)
Design Outdoor conditions : 17oC DB
Capacity correction value : 1.14
1.2
1.1
1
0.9
-5
0
5
10
15
20
25
30
35
o
40 43
Outdoor air dry bulb temp. ( C)
Outdoor air dry bulb temp. ( C)
*1 : Coefficient to use for correction of outdoor unit capacity when total capacity of the indoor
units are not equal to the outdoor unit capacity.
5 -1
Capacity correction value
Air flow variation ratio of indoor unit vs. capacity correction (For concealed duct type only)
1.1
1.0
0.9
80
90
100
110
120
Air flow variation ratio (%)
82
84
86
88
90
96
98
20
100%
Hight of outdoor unit H (m)
30
92
94
Connecting pipe length and lift difference between indoor and outdoor units vs. capacity correction value
10
0
-10
-20
0
10
20
30
40
50
60
70
80
90
100
Pipe length (Equivalent length) L(m)
hc
hb
ha
a
b
c
A
B Indoor unit
82
84
86
88
90
96
98
H = ho +
(Largest one of ha, hb, and hc)
30
20
100%
Ll
Hight of outdoor unit H (m)
ho
L is the longest one of
(Ll + a, Ll + b, Ll + c)
92
Outdoor unit
94
(Example)
Design Pipelength : 55m
Height of outdoor unit
: 15m
Capacity correction value : 89%
10
0
-10
-20
0
10
20
30
40
50
60
70
Pipe length (Equivalent length) L(m)
C
5 -2
80
90
100
(Example)
Design Outdoor unit
: 5.0HP
Indoor units total capacity : 5.5HP
(Capacity ratio
: 110%)
Capacity correction value : 1.03%
1.1
1
0.9
Capacity correction value
Capacity correction value
Correction of outdoor unit diversity
0.8
0.7
80
80
100
110
120
130
1.1
1
0.9
0.8
0.7
80
80
100
Standard capacity ratio
Indoor units total capacity ratio (%)
110
120
130
Standard capacity ratio
Indoor units total capacity ratio (%)
2 Heating capacity calculation method :
Required heating capacity = Heating capacity x Factor ( , ,
,
,
*1 ,
*2) kW
(Example)
Design Indoor conditions : 21.5oC DB
Capacity correction value : 0.98
1.2
Capacity correction value
Capacity correction value
Indoor air dry bulb temperature vs. capacity correction value
1.1
1.0
0.9
0.8
15
20
24
o
Indoor air dry bulb temp. ( C)
1.2
1.1
1.0
0.9
0.8
15
20
24
Indoor air dry bulb temp. (oC)
1.2
(Example)
Design Outdoor conditions : -5oC WB
Capacity correction value : 0.8
1.1
1
0.9
0.8
0.7
0.6
0.5
-15
-10
-5
0
5
10
15
Outdoor air wet bulb temp. (oC)
Capacity correction value
Capacity correction value
Outdoor air wet bulb temperature vs. capacity correction value
1.2
1.1
1
0.9
0.8
0.7
0.6
0.5
-15
-10
-5
0
5
10
Outdoor air wet bulb temp. (oC)
*1 : Coefficient to use for correction of outdoor unit capacity when total capacity of the indoor
units are not equal to the outdoor unit capacity.
*2 : Refer to item 3.
5 -3
15
Capacity correction value
Air flow variation ratio of indoor unit vs. capacity correction (For concealed duct type only)
1.1
1.0
0.9
80
90
100
110
120
Air flow variation ratio (%)
94
95
96
97
98
30
99
20
100%
Height of outdoor unit H (m)
Connecting pipe length and lift difference between indoor and outdoor units vs. capacity correction value
10
0
-10
-20
0
10
20
30
40
50
60
70
80
90
100
Pipe length (Equivalent length) L (m)
hc
hb
ha
a
b
c
A
B Indoor unit
94
95
97
98
20
99
H = ho +
(Largest one of ha, hb, and hc)
30
100%
Ll
Height of outdoor unit H (m)
ho
L is the longest one of
(Ll + a, Ll + b, Ll + c)
96
(Example)
Design Pipe length
: 75m
Heigh of outdoor unit : 15m
Capacity correction value : 95.1%
Outdoor unit
10
0
-10
-20
0
10
20
30
40
50
60
70
80
90
Pipe length (Equivalent length) L (m)
C
5 -4
100
Correction of outdoor unit diversity
Design Outdoor unit
: 5HP
Indoor units total capacity : 4.5HP
(Capacity ratio
: 90%)
Capacity correction value : 0.9%
1.1
1
0.9
Capacity correction value
Capacity correction value
(Example)
0.8
0.7
80
90
100
110
120
130
1.1
1
0.9
0.8
0.7
80
Standard capacity ratio
Indoor units total capacity ratio (%)
90
100
110
120
130
Standard capacity ratio
Indoor units total capacity ratio (%)
*1 : Coefficient to use for correction of outdoor unit capacity when total capacity of the indoor
units are not equal to the outdoor unit capacity.
3 Capacity correction in case of frost on the outdoor heat exchanger in heating
Correct the heating capacity when frost was found on the outdoor heat exchanger.
Heating capacity = Capacity after correction of outdoor unit × Correction value of capacity resulted from frost
(Capacity after correction of outdoor unit : Heating capacity calculated in the above item 2.)
Capacity correction value
Capacity correction in case of frost on the outdoor heat exchanger
1.0
0.9
0.8
-15
-10
-5
0
5
10
o
Outdoor air wet bulb temp. ( C)
4 Capacity calculation for each indoor unit
Capacity for each indoor unit
= Capacity after correction of outdoor unit x
Required standard capacity of indoor unit
Total value of standard indoor unit capacity
5 -5
5 Operating temperature range
In cooling time
In heating time
45
20
30
25
Continuously
operable
range
20
15
10
5
0
-5
-10
10
15
20
25
28
30
o
Indoor air wet bulb temp. ( C)
15
10
5
Usable range
(in warming-up)
Outdoor air wet bulb temp. (oC)
35
Usable range
(in pull down)
Outdoor air dry bulb temp. (oC)
40
0
-5
Continuously
operable
range
-10
-15
-20
5
10
15
20
25
30
Indoor air dry bulb temp. (oC)
6 Rated conditions
Cooling :
Indoor air temperature 27oC DB/19.0oC WB, Outdoor air temperature 35oC DB
Heating :
Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB/6oC WB
5 -6
6-1. Free branching system
Line branching system
2 Header branching system
3 Header branching system after line branching
4 Line branching system after header branching
5 Header branching system after header branching
The above five branching systems are available to dramatically increase the flexibility of refrigerant piping design.
1
Outdoor unit
Branching joint
Line
branching
system
Indoor unit
Remote
controller
Outdoor unit
Branching header
Header
branching
system
Indoor unit
Remote controller
* In case of "PMV Kit"
Outdoor unit
Header
branching
system
after line
branching
Branching joint
Branching header
PMV
Kit
Indoor unit
Remote
controller
* In case of "PMV Kit"
Line
branching
system after
header
branching
Outdoor unit
Branching header
Header
branching
system after
header
branching
Branching
joint
PMV
Kit
Indoor
unit
Remote
controller
6 -1
6-2. Refrigerant piping length and piping size
1
Allowable length and height difference of refrigerant piping
Outdoor unit
Main
pipe
L1
Branching pipe
L2
Branching header
a
1st branching
section
b
c
d
Branching
pipe
L3
Height
difference
between
Indoor and
outdoor unit
Indoor unit
Height difference
between indoor units
H2
H1
Equivalent length corresponded to farthest piping
L
Equivalent length corresponded to farthest piping after 1st branching Li
L4
e
f
Y-shape
branching joint
g
A
6 -2
1
Allowable length and height difference of refrigerant piping
Total extension of pipe
(Liquid pipe, real length)
Real length
Allowable value
Piping section
180m
L1+L2+L3+L4+
a+b+c+d+e+f+g
100m
Furthest piping length L
(*1)
L1+L3+L4+g
Equivalent
length
125m
Piping
Length
Max.equivalent length of
main pipe
65m
L1
Equivalent length of furthest
piping from 1st branching
Li (*1)
35m
L3+L4+g
Max.real length of indoor
unit connecting pipe
15m
a, b, c, d, e, f, g
Upper outdoor
unit
30m
_
Lower outdoor
unit
20m
_
15m
_
Height between indoor and
outdoor units H1
Height
Difference
Height between indoor units H2
*1 Furthest indoor unit from 1st branch to be named "A"
6 -3
2
Selection of refrigerant piping
Outdoor unit
Gas pipe
Main
pipe
Liquid pipe
1st branching
Branching
section
1
4
2 pipe
Branching header
4
3
3
3
3
Indoor unit
Branching Y-shape
pipe
Branching joint
4
2
2
4
3
3
3
Indoor unit
6 -4
2
Selection of refrigerant piping (cont.)
No. Piping parts
Name
Selection of pipe size
Size of main pipe
Outdoor unit
1
Gas pipe (mm) Liquid pipe (mm)
Outdoor unit capacity type
0401 type
15.9
9.5
0501 type
15.9
9.5
0601 type
19.1
9.5
Equivalent to HP
Gas pipe
(mm)
Liquid pipe
(mm)
Below 2.8
12.7
9.5
2.8 to below 6.4
15.9
9.5
6.4 to below 7.2
19.1
9.5
Main pipe
1st branching
section
Pipe size between branching sections
Total capacity codes of indoor units at down stream side
Branching
section
Branching
pipe
2
Branching
section
Note) If the total capacity code value of indoor units exceeds that of the
outdoor units, apply the capacity code of outdoor units.
Connecting pipe size of indoor unit
Branching
section
Indoor unit capacity type
Indoor unit
3
connecting
pipe
Indoor unit
Gas pipe (mm) Liquid pipe (mm)
007, 009, 012 type
9.5
6.4
015, 018 type
12.7
6.4
024, 030, 036, 048 type
15.9
9.5
Selection of branching section
Total capacity codes of indoor units at down stream side
Equivalent to HP
Y-shape
branching joint
4
Branching
section
Branching
header
Below 6.4
RBM-BY53E
6.4 to below 7.8
RBM-BY103E
For 4 branches
Below 7.8
RBM-HY1043E
For 8 branches
Below 7.8
RBM-HY1083E
Y-shape branching joint
Branching
header
Model name
Note) *1 : When using a Y-shape branching joint for the 1st branch, select
according to capacity code of the outdoor unit.
*2 : For 1 line after branching header indoor units with a maximum
capacity code of 6.0 in total can be connected.
Minimum wall thickness for R410A application
Soft
Harf Hard
or Hard
OD
(inch)
OD
(mm)
Minimum wall
thickness (mm)
OK
OK
1/4"
6.35
0.80
OK
OK
3/8"
9.52
0.80
OK
OK
1/2"
12.70
0.80
OK
OK
5/8"
15.88
1.00
NG*
OK
3/4"
19.05
1.00
6 -5
*If the pipe size is O/ 19.0 or more,
use a suitable material.
6-3. Refrigerant piping length and piping size with PMV Kit
1
Allowable length and height difference of refrigerant piping
Outdoor unit
Main
pipe
L1
Branching pipe
L2
Branching header
a
1st branching
section
b
c
d
PMV Kit
Branching
pipe
L3
h
i
Height
difference
between
Indoor and
outdoor unit
j
k
Indoor unit
Height difference
between indoor units
(PMV Kit) H2
H1
Equivalent length corresponded to farthest piping
L
Equivalent length corresponded to farthest piping after 1st branching
Li
L4
e
Y-shape
Branching joint
f
l
m
g
n
A
6 -6
1
Allowable length and height difference of refrigerant piping
Total extension of pipe
(Liquid pipe, real length)
Real length
Allowable value
Piping section
150m
L1+L2+L3+L4+
a+b+c+d+e+f+g+
h+i+j+k+l+m+n
65m
Furthest piping length L
(*1)
L1+L3+L4+g+n
Equivalent
length
80m
Piping
Length
Max.equivalent length of main pipe
50m
L1
Equivalent length of furthest
piping from 1st branching Li
(*1)
15m
L3+L4+g+n
Max.real length of indoor unit connecting pipe
15m
a+h, b+i, c+j, d+k,
e+l, f+m, g+n
Real length between PMV Kit and indoor unit
2m or more
and up to 10m
h, i, j, k, l, m, n
Upper outdoor
unit
30m
_
Lower outdoor
unit
20m
_
15m
_
Height between indoor and
outdoor unit H1
Height
Difference
Height between indoor units (PMV Kit) H2
Height difference between highest indoor unit or PMV Kit and
lowest indoor unit or PMV Kit shall be 15m or less
*1 Furthest indoor unit from 1st branch to be named "A"
Not Available
PMV
Kit
Available
PMV
Kit
Indoor unit
Indoor unit
NOTE
,
Don t connect two or more indoor units to one PMV Kit. Arrange one indoor unit and one PMV Kit set to 1 by 1.
6 -7
2
Selection of refrigerant piping
Outdoor unit
Gas pipe
Main
pipe
Liquid pipe
1st branching
Branching
section
1
4
2 pipe
Branching header
4
5
5
3
3
5
3
5
3
Indoor unit
Y-shape
Branching
Branching
joint
pipe
4
2
2
3
PMV Kit
4
5
3
5
3
Indoor unit
6 -8
5
2
Selection of refrigerant piping (cont.)
No. Piping parts
Name
Selection of pipe size
Size of main pipe
Outdoor unit
1
Gas pipe (mm) Liquid pipe (mm)
Outdoor unit capacity type
0401 type
15.9
9.5
0501 type
15.9
9.5
0601 type
19.1
9.5
Equivalent to HP
Gas pipe
(mm)
Liquid pipe
(mm)
Below 2.8
12.7
9.5
2.8 to below 6.4
15.9
9.5
6.4 to below 7.2
19.1
9.5
Main pipe
1st branching
section
Pipe size between branching sections
Total capacity codes of indoor units at down stream side
Branching
section
Branching
pipe
2
Branching
section
Note) If the total capacity code value of indoor units exceeds that of the
outdoor units, apply the capacity code of outdoor units.
Connecting pipe size of indoor unit
Branching
section
Indoor unit capacity type
Indoor unit
3
connecting
pipe
Indoor unit
Gas pipe (mm) Liquid pipe (mm)
007, 009, 012 type
9.5
6.4
015, 018 type
12.7
6.4
024 type
15.9
9.5
Selection of branching section
Total capacity codes of indoor units at down stream side
Equivalent to HP
Y-shape
branching joint
4
Branching
section
Branching
header
Y-shape branching joint
*1
Branching For 4 branches
header
For 8 branches
*2
Model name
Below 6.4
RBM-BY53E
6.4 to below 7.8
RBM-BY103E
Below 7.8
RBM-HY1043E
Below 7.8
RBM-HY1083E
Note) *1 : When using a Y-shape branching joint for the 1st branch, select
according to capacity code of the outdoor unit.
*2 : For 1 line after branching header indoor units with a maximum
capacity code of 6.0 in total can be connected.
Selection of PMV Kit
5
PMV Kit
PMV Kit
Indoor unit capacity type
Model name
007, 009, 012 type
RBM-PMV0361E
015, 018, 024 type
PBM-PMV0901E
Minimum wall thickness for R410A application
Soft
Harf Hard
or Hard
OD
(inch)
OD
(mm)
Minimum wall
thickness (mm)
OK
OK
1/4"
6.35
0.80
OK
OK
3/8"
9.52
0.80
OK
OK
1/2"
12.70
0.80
OK
OK
5/8"
15.88
1.00
NG*
OK
3/4"
19.05
1.00
6 -9
*If the pipe size is O/ 19.0 or more,
use a suitable material
as detailed in the installation manual.
6-4. Refrigerant piping example
1
In case of without "PMV Kit"
Outdoor unit
MCY-MAP0601HT
Main
L1 =60m pipe
Branching pipe
(7.6)
2
(3.4)
Branching header
L2 =7m
1st branching
section 1
Branching pipe
L3
Capacity
code
a
=1m
=20m
(0.8)
b
=6m
c
(1.0)
=8m
(0.8)
d
10m
=15m
(0.8)
MMU-AP0071MH MMU-AP0091H MMU-AP0701MH MMU-AP0701MH
Indoor unit
(4.2)
f
=10m
e =4m (1.7)
Y-shape
Branching joint 3
12m
(2.5)
MMU-AP0151H
MMU-AP0241H
6 -10
Piping size
Mark
Equivalent length
(m)
L1
60
L2
7
L3
Seclection method
(capacity code)
Gas pipe
(mm)
Liquid pipe
(mm)
O
/ 19.1
O
/ 9.5
0.8 + 1.0 + 0.8 + 0.8 = 3.4
O
/ 15.9
O
/ 9.5
20
1.7 + 2.5 = 4.2
O
/ 15.9
O
/ 9.5
a
1
0.8
O
/ 9.5
O
/ 6.4
b
6
1.0
O
/ 9.5
O
/ 6.4
c
8
0.8
O
/ 9.5
O
/ 6.4
d
15
0.8
O
/ 9.5
O
/ 6.4
e
4
1.7
O
/ 12.7
O
/ 6.4
f
10
2.5
O
/ 15.9
O
/ 9.5
Y-shape branching joint and Header
Mark
Y-joint or Header select
(capacity code)
Model name
1
1st branching
6
(capacity code of outdoor unit)
RBM-BY53E
2
Branch header
0.8 +1.0 +0.8 +0.8 = 3.4
(a+b+c+d=L2)
RBM-HY1043E
3
Y-shape branch joint
1.7 + 2.5 = 4.2
(e+f=L3)
RBM-BY53E
6 -11
2
In cace of PMV Kit
Outdoor unit
MCY-MAP0601HT
Main
L1 =20m pipe
Branching pipe
(7.6)
2
(3.4)
Branching header
L2 =3m
1st branching
section 1
Branching pipe
L3
Capacity
code
a
=4m
=6m
(0.8)
b
=3m
c
(1.0)
=6m
d
(0.8)
10m
=7m
(0.8)
MMU-AP0071MH MMU-AP0091H MMU-AP0701MH MMU-AP0701MH
Indoor unit
(4.2)
f
=6m
12m
e =4m (1.7)
Y-shape
Branching joint 3
(2.5)
MMU-AP0151H
PMV Kit
MMU-AP0241H
6 -12
Piping size
Mark
Equivalent length
(m)
L1
20
L2
3
L3
Seclection method
(capacity code)
Gas pipe
(mm)
Liquid pipe
(mm)
O
/ 19.1
O
/ 9.5
0.8 + 1.0 + 0.8 + 0.8 = 3.4
O
/ 15.9
O
/ 9.5
6
1.7 + 2.5 = 4.2
O
/ 15.9
O
/ 9.5
a
4
0.8
O
/ 9.5
O
/ 6.4
b
3
1.0
O
/ 9.5
O
/ 6.4
c
6
0.8
O
/ 9.5
O
/ 6.4
d
7
0.8
O
/ 9.5
O
/ 6.4
e
4
1.7
O
/ 12.7
O
/ 6.4
f
6
2.5
O
/ 15.9
O
/ 9.5
Y-shape branching joint and Header
Mark
1
1st branching
2
Branch header
3
Y-shape branch joint
Y-joint or Header select
(capacity code)
Model name
6
(capacity code of outdoor unit)
RBM-BY53E
0.8 +1.0 +0.8 +0.8 = 3.4
(a+b+c+d=L2)
1.7 + 2.5 = 4.2
(e+f=L3)
RBM-HY1043E
RBM-BY53E
PMV Kit
Mark
PMV Kit select
(capacity code)
Model name
0.8
RBM-PMV0361E
1.0
RBM-PMV0361E
0.8
RBM-PMV0361E
0.8
RBM-PMV0361E
1.7
RBM-PMV0901E
2.5
RBM-PMV0901E
6 -13
6-5. Charging requirement with additional refrigerant
After the system has been vacuumed,replace the vacuum pump
with a refrigerant cylinder and charge the system
with additional refrigerant.
R410A
Calculating the amount of additional refrigerant required
(Calculation)
Additional refrigerant charge amount is calculated from size of liquid pipe at site and its real length.
Additional refrigerant
Real length of
R (kg) =
charge amount at site
liquid pipe
Additional refrigerant charge
+
X amount per liquid pipe 1m
(Table 1)
Compensation by
outdoor HP
(Table 2)
Table 1
Pipe dia. at liquid side
Additional refrigerant amount/1m (kg)
O
/ 6.4
O
/ 9.5
0.025
0.055
0401 type
-0.8
0501 type
-0.4
Table 2
Outdoor unit capacity type
Compensation by outdoor HP (kg)
0601 type
0
Example :
(0501 type)
a
L1
b
O
/ 9.5 : 10m
O
/ 6.4 : 3m
L3
L2
L1
L2
c
b
O
/ 9.5 : 10m
O
/ 6.4 : 4m
c
L3
d
d
O
/ 9.5 : 5m
a
O
/ 9.5 : 3m
O
/ 6.4 : 5m
Additional charge amount R (kg) = (Lx X 0.025kg/m) + (Ly X 0.055kg/m) + (-0.4kg)
= (12 X 0.025kg) + (28 X 0.055kg) + (-0.4kg)
=1.44kg
Lx : Real total length of liquid pipe O
/ 6.4 (m)
Ly : Real total length of liquid pipe O
/ 9.5 (m)
Note)
If the additional refrigerant amount indicates a negative result from the calculation,
use air conditioner without the adding of any additional refrigerant.
6 -14
7-1. Outdoor unit
Sensor (TO)
Heat exchanger
Strainer
Sensor
(TE)
PMV
Strainer
Sensor (TL)
Capillary
tube 2
Solenoid valve
(SV5)
4-Way valve
Sensor (TS)
Check valve
Solenoid valve
(SV2)
Liquid tank
Check joint
Capillary
tube 1
Low-pressure
sensor
High-pressure
sensor
Solenoid valve
(SV4)
High pressure
switch
Check joint
Muffler
Sensor (TD)
Accumulator
Check joint
Strainer
Compressor (Inverter)
Liquid side
packed valve
Gas side
ball valve
7 -1
7-2. Explanation of Functional Parts
Functional part name
Solenoid valve
SV2
SV4
SV5
Capillary tube
1
2
4-Way valve
PMV
(Pulse motor valve)
Temp. sensor
TD
TS
TE
TL
TO
High-ressure sensor
Low-pressure sensor
Compressor case heater
Accumulator case heater
Functional outline
1) Low pressure release function
2) High pressure release function
3) Gas balance function during off time
4) Hot gas bypass into accumulator
1) High pressure release function
2) Low pressure release function
1) Preventive function for high-pressure rising
in heating operation
ID:Ø1.5 Length:200mm
ID:Ø2.2 Length:100mm
1) Cooling/heating exchange
2) Reverse defrost
1) Super heat control function in all heating and majority
heating operation
2) Sub-cool adjustment function in cooling operation
1) Protection of compressor discharge temp. Used for release
1) Controls super heat in heating operation
1) Controls defrost in heating operation
2) Controls outdoor fan in heating operation
1) Detects under cool in cooling operation
1) Detects outside temperature
1) Detects high pressure and controls compressor capacity
2) Detects high pressure in cooling operation, and controls
the fan in low ambientcooling operation
1) Detects low pressure in cooling operation and controls
compressor capacity
2) Detects low pressure in heating operation, and controls
the super heat
1) Prevents liquid accumulation to compressor
1) Prevents liquid accumulation to accumulator
7 -2
Connector
CN312(Whight)
CN311(Blue)
CN310(Whight)
CN317(Blue)
CN300(Whight)
CN502(Whight)
CN504(Whight)
CN505(Green)
CN521(Whight)
CN507(Yellow)
CN501(Red)
CN500(Whight)
CN316(Whight)
CN321(Red)
7-3. Indoor Unit
Liquid side Gas side
Strainer
Capillary tube
Air heat exchanger
at indoor side
Pulse Motor
Valve (PMV)
Strainer
Sensor
(TCJ)
Sensor
(TC2)
Fan
Sensor
(TC1)
Sensor
(TA)
M
Fan motor
(NOTE) MMU-AP0071YH to AP0121YH type air conditioners do not have a TC2 sensor .
Functional part name
Pulse Motor Valve PMV
Temp. sensor
Functional outline
(Connector CN082 (6P): Blue)
1)Controls super heat in cooling operation
2)Controls under cool in heating operation
3)Recovers refrigerant oil in cooling operation
4)Recovers refrigerant oil in heating operation
1. TA
(Connector CN104 (2P): Yellow)
1)Detects indoor suction temperatur e
2. TC1
(Connector CN100 (3P): Brown)
1)Controls PMV super heat in cooling operation
3. TC2
(Connector CN101 (2P): Black)
1)Controls PMV under cool in heating operation
4. TCJ
(Connector CN102 (2P): Red)
1)Controls PMV super heat in cooling operation
2) MMU-AP0071 to AP0121YH only
Controls PMV under cool in heating operation
7 -3
CAUTIONS
(1) Keep the refrigerant piping system and the indoor-indoor/indoor-outdoor control wiring systems together.
(2) When running power supplies and control wires parallel to each other, run them through separate conduits or
maintain a suitable distance between them.
(Current capacity of power supplies: 10A or less for 300m, 50A or less for 500m)
8-1. General
Perform wiring of the power supplies in conformance with the regulation of
the local electrical company.
Use a 2 core shield wire for control wiring on connecting indoor units,
and connecting of indoor units to outdoor units.
This is recommended to prevent possible noise issues.
Be sure to connect an earth leakage breaker to the power supply of
the indoor units.
Never connect 220-240V power to the control wiring terminal block
(U1,U2,U3,U4). Fault will be caused.
Locate wiring system for the control and refrigerant piping system
in the same line.
Arrange the cables so that the electrical wires do not come in to contact
with high-temperature parts of the pipework ; otherwise insulation will melt
and an accident may be caused.
Do not turn on the power supply of the indoor units until vacuuming of
the refrigerant pipe has finished.
8-2. Connection of power supply
The details are as follows.
(Terminal block)
(Stripping length power cable)
L N
10
10
L
N
90
50
Earth line
Power cable
(Cord clamp)
Power cable
(Protective bush : Accessory)
Power supply specifications
Select the power supply cabling and fuse of each outdoor unit from the following
specifications:
3 core cable in conformance with Design 60245 IEC 66
Do not connect the units looping via the terminal blocks (L,N)
8 -1
8-3. Electrical wiring desin
/%; /#2*6UGTKGU
0` *\8 8
/%;/#2*6&UGTKGU
2QYGTUWRRN[
0`*\ 8
'CTVJ
.
Outdoor
power source
0
1XGTEWTTGPV
DTGCMGT
HWUGUYKVEJ
Earth leakage Breaker
hand switch
Over current breaker
(fuse) switch
'CTVJNGCMCIGDTGCMGT
1WVFQQTWPKV RQYGT UWRRN[
Pull box
Indoor
power source
Single phase
50Hz 220-240V
or 60Hz 220V
Earth leakage breaker
power switch
Indoor unit
Indoor unit
Indoor unit
Indoor unit
Indoor unit
Indoor unit
Determine the wire size for the indoor unit according to the number of
conncted indoor units downstream.
Outdoor Unit capacities and power supply wire sizes (Reference)
Observe local regulations in reference to the wire size selection and installtion.
Wire size *
Outdoor unit capacity type
Field fuse
2
0401 type
0501 type
0601 type
6 mm Max. 22 m
6 mm2 Max. 19 m
6 mm2 Max. 17 m
32A
32A
40A
* Desi gn 60245 IEC66
For Indoor Unit power supply
(Must be independent from the outdoor unit power supply )
Item
Power supply wiring
Model
All models of indoor units
Wire size
2.0mm2 MAX.20m
Field fuse
3.5mm2 MAX.50m
NOTE:
The above connecting lengths stated in the table indicate the length from the isolator to the outdoor unit. When the
power supply of the indoor units are connected in parallel, it is assumed that no more than a 2% voltage drop will occur.
If the connecting length is to exceed the stated lengths, select a suitable wire in accordance with the local wiring standards.
8
-2 (Revised edition in 7.Apr.2006)
15A
8-4. Design of control wiring
Power supply
Single phase
220-240V 50Hz
220Hz
(Open)
60Hz
Earth
Communication wire for control
between outdoor unit and
indoor unit
Connection of shield wire must be connected
(Connected to all connecting sections in each indoor unit)
[Central remote controller] (Option)
TCB-SC642TLE2 (For line 64)
Communication wire for
control between indoor
and PMV Kit
(Follower)
(Header)
PMV Kit (option)
Remote
controller
Communication wire for
control between indoor
and PMV Kit (option)
Control device
Mini-SMMS system
U1 U2
U3 U4
A
Outdoor
unit
U3 U4
Outdoor
unit
Outdoor
unit
U3 U4
U3 U4
Outdoor unit
U1 U2
U1 U2
U1 U2
U1 U2
Indoor unit
A B
B
B
B
U1 U2
U1 U2
A B
Remote
controller
U1 U2
A B
U1 U2
A B
U1 U2
A B
U1 U2
A B
Remote controller
U1 U2
A B
A B
Remote controller
Wire specification, quantity, size of crossover wiring and remote controller wiring
Name
Crossover wiring (A + B)
(indoor-indoor / indoor-outdoor / control wiring,
central control wiring) *Total Control wiring length
Remote controller wiring
Control wiring between indoor and PMV Kit
Q’ty
Up to 500m
1.25mm2
2 cores
2 cores
Size
Up to 1000m
0.5 to 2.0mm2
-
1000 to 2000m
Specification
2.0mm2
Shield wire
-
-
Be sure to use the attached cable. MIN 2m - MAX 10m
(1) The crossover wiring and central control wiring uses a 2-core non-polarity communication wire. Use 2-core shielded wire to prevent
possible noise issues. Connect the end of the shielded wires and earth(ground) at both the outdoor and indoor unit.
Where the shielded wire is connected between a central controller and a outdoor unit, only earth(ground) at one end of
the central control line.
(2) Use 2-core non-polarity wire for remote controller. (A, B terminals)
Use 2-core non-polarity wire for wiring of group control. (A, B terminals)
8 -3
8-5. Example of system wiring Design
1
In cace of without "PMV Kit"
Outdoo r pow er supply
MCY-MAP###1HT series : 1N~ 50Hz 220V-240V
MCY-MAP###1HT2D series : 1N~ 60Hz 220V
Outdo or unit
Indoor unit
Remote contr oller
Central r emote contr oller (o ption)
Over cur rent b reaker (f use) sw itch
Earth leaka ge breaker
Main sw itch
Pull bo x
PMV Kit (opt ion)
Centr al remot e contro lle r pow er supply
1N~ 50Hz 220-240V
1N~ 60Hz 220V
(Option)
L N
Earth
U1 U2
U3 U4
(Open)
(Open)
To other
refrigerant system
[Outdo or un it]
L N
U1 U2 U3 U4
Earth
Relay connector (At shipment from factory : No connection)
Connection of shield wire must be connected
(Connected to all connecting sections in each Indoor un
Control wiring between indoor units
[Indoo r unit ]
U1 U2 A B
control
U1 U2 A B
Eart h
ad
U1 U2 A B
Eart h
L N
Earth
L N
L N
Eart h
L N
A B
A B
A B
Remote cont roller
[Grou p cont rol]
Indoor unit
power supply
1N~ 50Hz 220-240V
1N~ 60Hz 220V
8 -4
U1 U2 A B
2
In cace of "PMV Kit"
Outdoo r pow er supply
MCY-MAP###1HT series : 1N~ 50Hz 220V-240V
MCY-MAP###1HT2D series : 1N~ 60Hz 220V
Outdo or unit
Indoor unit
Remote contr oller
Central r emote contr oller (o ption)
Over cur rent b reaker (f use) sw itch
Earth leaka ge breaker
Main sw itch
Pull bo x
PMV Kit (opt ion)
Central remote controlle r power supply
1N~ 50Hz 220-240V
1N~ 60Hz 220V
(Option)
L N
Earth
U1 U2
U3 U4
(Open)
(Open)
To other
refrigerant system
[Outdo or un it]
L N
U1 U2 U3 U4
Earth
Relay connector (At shipment from factory : No connection)
Connection of shield wire must be connected
(Connected to all connecting sections in each Indoor un
Control wiring between indoor units
[Indoo r unit ]
U1 U2 A B
PMV Kit (option)
Indoor control
Indoor control
PC boad
PC boad
CN82
U1 U2 A B
Eart h
U1 U2 A B
Eart h
L N
Earth
L N
L N
Eart h
L N
A B
A B
A B
Remote cont roller
[Grou p cont rol]
Indoor unit
power supply
1N~ 50Hz 220-240V
1N~ 60Hz 220V
8 -5
U1 U2 A B
8-6. Electrical characteristics
50Hz
Outdoor units
Model name
Nominal
(V-Ph-Hz)
MCY-MAP0401HT
MCY-MAP0501HT
MCY-MAP0601HT
230-1-50
230-1-50
230-1-50
Voltage Range
Min
Max
198
264
198
264
198
264
Legend
RLA : Rated Load Amps
FLA : Full Load Amps
kW : Fan Motor Rated Output (kW)
NOTE
Compressor
Fan Motor
RLA
kW
FLA
0.063 x 2
1.2
22.4
0.063 x 2
1.3
25.3
0.063 x 2
1.3
27.8
Power Supply
MCA MOCP
ICF
25
32
28
32
31
40
-
MCA : Minimum Circuit Amps
MOCP : Maximum Overcurrent Protection (Amps)
ICF : Maximum Instantaneous Current Flow Start
: RLA is based on the following conditions.
Indoor temperature : 27oCDB / 19oCWB
Outdoor temperature : 35oCDB
50Hz
Indoor units
Type
4-way Air
Discharge
Cassette Type
Compact
4-way Cassette
(600 x 600) Type
2-way Air
Discharge
Cassette Type
1-way Air
Discharge
Cassette Type
Model
MMU-AP 0091 H
MMU-AP 0121 H
MMU-AP 0151 H
MMU-AP 0181 H
MMU-AP 0241 H
MMU-AP 0271 H
MMU-AP 0301 H
MMU-AP 0361 H
MMU-AP 0481 H
MMU-AP 0071 MH
MMU-AP 0091 MH
MMU-AP 0121 MH
MMU-AP 0151 MH
MMU-AP 0181 MH
MMU-AP 0071 WH
MMU-AP 0091 WH
MMU-AP 0121 WH
MMU-AP 0151 WH
MMU-AP 0181 WH
MMU-AP 0241 WH
MMU-AP 0271 WH
MMU-AP 0301 WH
MMU-AP 0071 YH
MMU-AP 0091 YH
MMU-AP 0121 YH
MMU-AP 0152 SH
MMU-AP 0182 SH
MMU-AP 0242 SH
Nominal Voltage
(V-Ph-Hz)
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
220-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
8 -6
Voltage Range
Min
Max
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
Fan Motor
kW
FLA
0.20
0.060
0.20
0.060
0.22
0.060
0.24
0.060
0.28
0.060
0.28
0.060
0.40
0.060
0.68
0.090
0.93
0.090
0.32
0.060
0.35
0.060
0.36
0.060
0.48
0.060
0.48
0.060
0.36
0.053
0.36
0.053
0.36
0.053
0.37
0.039
0.37
0.039
0.53
0.053
0.53
0.053
0.54
0.053
0.28
0.022
0.28
0.022
0.28
0.022
0.40
0.030
0.42
0.030
0.71
0.030
Power Supply
MCA MOCP
15
0.25
15
0.25
15
0.28
15
0.30
15
0.35
15
0.35
15
0.50
15
0.85
15
1.16
15
0.40
15
0.44
15
0.45
15
0.60
15
0.60
15
0.45
15
0.45
15
0.45
15
0.46
15
0.46
15
0.66
15
0.66
15
0.68
15
0.35
15
0.35
15
0.35
15
0.49
15
0.53
15
0.88
50Hz
Indoor units
Type
Model
MMD-AP 0071 BH
MMD-AP 0091 BH
MMD-AP 0121 BH
MMD-AP 0151 BH
MMD-AP 0181 BH
MMD-AP 0241 BH
MMD-AP 0271 BH
MMD-AP 0301 BH
MMD-AP 0361 BH
MMD-AP 0481 BH
MMD-AP 0071 SPH
Slim Duct Type
MMD-AP 0091 SPH
MMD-AP 0121 SPH
MMD-AP 0151 SPH
MMD-AP 0181 SPH
MMD-AP 0181 H
Concealed Duct
MMD-AP 0241 H
High Static
MMD-AP 0271 H
Pressure Type
MMD-AP 0361 H
MMD-AP 0481 H
MMC-AP 0151 H
Under Ceiling Type
MMC-AP 0181 H
MMC-AP 0241 H
MMC-AP 0271 H
MMC-AP 0361 H
MMC-AP 0481 H
MMK-AP 0071 H
High Wall 1series
MMK-AP 0091 H
Type
MMK-AP 0121 H
MMK-AP 0151 H
MMK-AP 0181 H
MMK-AP 0241 H
MMK-AP 0072 H
High Wall 2series
MMK-AP 0092 H
Type
MMK-AP 0122 H
MML-AP 0071 H
Floor Standing
MML-AP 0091 H
Cabinet Type
MML-AP 0121 H
MML-AP 0151 H
MML-AP 0181 H
MML-AP 0241 H
MML-AP 0071 BH
Floor Standing
MML-AP 0091 BH
Concealed Type
MML-AP 0121 BH
MML-AP 0151 BH
MML-AP 0181 BH
MML-AP 0241 BH
MMF-AP 0151 H
Floor Standing
MMF-AP 0181 H
Type
MMF-AP 0241 H
MMF-AP 0271 H
MMF-AP 0361 H
MMF-AP 0481 H
Concealed Duct
Type
Nominal Voltage
(V-Ph-Hz)
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
220-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
Voltage Range
Min
Max
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
264
198
8 -7
Fan Motor
kW
FLA
0.33
0.120
0.33
0.120
0.39
0.120
0.39
0.120
0.50
0.120
0.60
0.120
0.60
0.120
0.70
0.120
0.96
0.120
1.13
0.120
0.35
0.060
0.35
0.060
0.37
0.060
0.38
0.060
0.47
0.060
0.93
0.160
1.55
0.160
1.55
0.160
1.87
0.260
2.12
0.260
0.33
0.030
0.37
0.030
0.48
0.040
0.48
0.040
0.90
0.080
0.96
0.080
0.35
0.030
0.35
0.030
0.35
0.030
0.37
0.030
0.37
0.030
0.40
0.030
0.20
0.030
0.21
0.030
0.22
0.030
0.30
0.045
0.30
0.045
0.49
0.045
0.49
0.045
0.54
0.070
0.54
0.070
0.29
0.019
0.29
0.019
0.29
0.019
0.52
0.070
0.52
0.070
0.53
0.070
0.77
0.037
0.77
0.037
1.01
0.063
1.01
0.063
1.48
0.110
1.84
0.160
Power Supply
MCA MOCP
15
0.41
15
0.41
15
0.49
15
0.49
15
0.62
15
0.75
15
0.75
15
0.88
15
1.20
15
1.41
15
0.44
15
0.44
15
0.47
15
0.48
15
0.59
15
1.16
15
1.94
15
1.94
15
2.34
15
2.65
15
0.41
15
0.46
15
0.60
15
0.60
15
1.13
15
1.20
15
0.44
15
0.44
15
0.44
15
0.46
15
0.46
15
0.50
15
0.24
15
0.26
15
0.27
15
0.37
15
0.37
15
0.62
15
0.62
15
0.68
15
0.68
15
0.36
15
0.36
15
0.36
15
0.65
15
0.65
15
0.66
15
0.96
15
0.96
15
1.27
15
1.27
15
1.85
15
2.30
8-6. Electrical characteristics
60Hz
Outdoor units
Model name
Nominal
(V-Ph-Hz)
MCY-MAP0401HT2D
MCY-MAP0501HT2D
MCY-MAP0601HT2D
220-1-60
220-1-60
220-1-60
Voltage Range
Min
Max
198
242
198
242
198
242
Legend
RLA : Rated Load Amps
FLA : Full Load Amps
kW : Fan Motor Rated Output (kW)
NOTE
Compressor
Fan Motor
RLA
kW
FLA
0.063 x 2
1.2
22.4
0.063 x 2
1.3
25.3
0.063 x 2
1.3
27.8
Power Supply
MCA MOCP
ICF
25
32
28
32
31
40
-
MCA : Minimum Circuit Amps
MOCP : Maximum Overcurrent Protection (Amps)
ICF : Maximum Instantaneous Current Flow Start
: RLA is based on the following conditions.
Indoor temperature : 27oCDB / 19oCWB
Outdoor temperature : 35oCDB
60Hz
Indoor units
Type
4-way Air
Discharge
Cassette Type
Compact
4-way Cassette
(600 x 600) Type
2-way Air
Discharge
Cassette Type
1-way Air
Discharge
Cassette Type
Model
MMU-AP 0091 H
MMU-AP 0121 H
MMU-AP 0151 H
MMU-AP 0181 H
MMU-AP 0241 H
MMU-AP 0271 H
MMU-AP 0301 H
MMU-AP 0361 H
MMU-AP 0481 H
MMU-AP 0071 MH
MMU-AP 0091 MH
MMU-AP 0121 MH
MMU-AP 0151 MH
MMU-AP 0181 MH
MMU-AP 0071 WH
MMU-AP 0091 WH
MMU-AP 0121 WH
MMU-AP 0151 WH
MMU-AP 0181 WH
MMU-AP 0241 WH
MMU-AP 0271 WH
MMU-AP 0301 WH
MMU-AP 0071 YH
MMU-AP 0091 YH
MMU-AP 0121 YH
MMU-AP 0152 SH
MMU-AP 0182 SH
MMU-AP 0242 SH
Nominal Voltage
(V-Ph-Hz)
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
8 -8
Voltage Range
Min
Max
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
Fan Motor
kW
FLA
0.21
0.060
0.21
0.060
0.23
0.060
0.25
0.060
0.29
0.060
0.29
0.060
0.42
0.060
0.70
0.090
0.98
0.090
0.31
0.060
0.33
0.060
0.35
0.060
0.47
0.060
0.47
0.060
0.38
0.053
0.38
0.053
0.38
0.053
0.44
0.039
0.44
0.039
0.61
0.053
0.61
0.053
0.67
0.053
0.30
0.022
0.30
0.022
0.30
0.022
0.40
0.030
0.45
0.030
0.75
0.030
Power Supply
MCA MOCP
15
0.26
15
0.26
15
0.29
15
0.31
15
0.37
15
0.37
15
0.52
15
0.88
15
1.22
15
0.39
15
0.41
15
0.44
15
0.59
15
0.59
15
0.47
15
0.47
15
0.47
15
0.55
15
0.55
15
0.76
15
0.76
15
0.84
15
0.37
15
0.37
15
0.37
15
0.50
15
0.57
15
0.94
60Hz
Indoor units
Type
Model
MMD-AP 0071 BH
MMD-AP 0091 BH
MMD-AP 0121 BH
MMD-AP 0151 BH
MMD-AP 0181 BH
MMD-AP 0241 BH
MMD-AP 0271 BH
MMD-AP 0301 BH
MMD-AP 0361 BH
MMD-AP 0481 BH
MMD-AP 0071 SPH
Slim Duct Type
MMD-AP 0091 SPH
MMD-AP 0121 SPH
MMD-AP 0151 SPH
MMD-AP 0181 SPH
MMD-AP 0181 H
Concealed Duct
MMD-AP 0241 H
High Static
MMD-AP 0271 H
Pressure Type
MMD-AP 0361 H
MMD-AP 0481 H
MMC-AP 0151 H
Under Ceiling Type
MMC-AP 0181 H
MMC-AP 0241 H
MMC-AP 0271 H
MMC-AP 0361 H
MMC-AP 0481 H
MMK-AP 0071 H
High Wall 1series
MMK-AP 0091 H
Type
MMK-AP 0121 H
MMK-AP 0151 H
MMK-AP 0181 H
MMK-AP 0241 H
MMK-AP 0072 H
High Wall 2series
MMK-AP 0092 H
Type
MMK-AP 0122 H
MML-AP 0071 H
Floor Standing
MML-AP 0091 H
Cabinet Type
MML-AP 0121 H
MML-AP 0151 H
MML-AP 0181 H
MML-AP 0241 H
MML-AP 0071 BH
Floor Standing
MML-AP 0091 BH
Concealed Type
MML-AP 0121 BH
MML-AP 0151 BH
MML-AP 0181 BH
MML-AP 0241 BH
MMF-AP 0151 H
Floor Standing
MMF-AP 0181 H
Type
MMF-AP 0241 H
MMF-AP 0271 H
MMF-AP 0361 H
MMF-AP 0481 H
Concealed Duct
Type
Nominal Voltage
(V-Ph-Hz)
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
220-1-60
Voltage Range
Min
Max
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
242
198
8 -9
Fan Motor
kW
FLA
0.35
0.120
0.35
0.120
0.41
0.120
0.41
0.120
0.52
0.120
0.63
0.120
0.63
0.120
0.73
0.120
1.00
0.120
1.18
0.120
0.32
0.060
0.32
0.060
0.36
0.060
0.37
0.060
0.44
0.060
1.06
0.160
2.07
0.160
2.07
0.160
2.38
0.260
2.60
0.260
0.35
0.030
0.39
0.030
0.50
0.040
0.50
0.040
0.94
0.080
1.00
0.080
0.37
0.030
0.37
0.030
0.37
0.030
0.39
0.030
0.39
0.030
0.030
0.40
0.030
0.21
0.030
0.22
0.030
0.23
0.045
0.29
0.045
0.29
0.045
0.51
0.045
0.51
0.070
0.61
0.070
0.61
0.019
0.31
0.019
0.31
0.019
0.31
0.070
0.53
0.070
0.53
0.070
0.59
0.037
0.77
0.037
0.77
0.063
1.04
0.063
1.04
0.110
1.58
0.160
2.01
Power Supply
MCA MOCP
15
0.43
15
0.43
15
0.51
15
0.51
15
0.65
15
0.78
15
0.78
15
0.91
15
1.25
15
1.48
15
0.41
15
0.41
15
0.45
15
0.47
15
0.56
15
1.32
15
2.59
15
2.59
15
2.98
15
3.25
15
0.43
15
0.48
15
0.63
15
0.63
15
1.18
15
1.25
15
0.46
15
0.46
15
0.46
15
0.48
15
0.48
15
0.50
15
0.26
15
0.27
15
0.29
15
0.36
15
0.36
15
0.63
15
0.63
15
0.76
15
0.76
15
0.39
15
0.39
15
0.39
15
0.66
15
0.66
15
0.73
15
0.96
15
0.96
15
1.29
15
1.29
15
1.97
15
2.52
50Hz
9-1-1. Specifications
Specifications (50Hz)
Model name
MMU- AP0091H AP0121H AP0151H AP0181H AP0241H AP0271H AP0301H AP0361H AP0481H
Cooling/Heating capacity (Note 1)
(kW)
3.6/4.0
4.5/5.0
5.6/6.3
7.1/8.0
8.0/9.0
9.0/10.0 11.2/12.5 14.0/16.0
1 phase 50Hz 230V (220-240V) (Separate power supply for indoor units is required.)
Power supply
Electrical
characteristics
2.8/3.2
Running current
(A)
0.17
0.19
0.21
0.24
0.35
0.59
0.81
Power consumption
(kW)
0.020
0.022
0.026
0.032
0.048
0.070
0.110
Starting current
(A)
0.30
0.33
0.36
0.42
0.59
0.87
1.23
Heat-insulating material attached Zinc hot dipping steel plate
Main unit
Appearance
Ceiling
panel
RBC-U21PG (W)-E
Model
Moon white (Munsell/2.5GY 9.0/0.5)
Panel color
256
Height (mm)
Main unit
Outer
dimension
Ceiling
panel
319
Width (mm)
840
Depth (mm)
840
Height (mm)
35
Width (mm)
950
Depth (mm)
950
Main unit
(kg)
Ceiling panel
(kg)
20
22
23
28
Total weigh
4.5
Finned tube
Heat exchanger
Soundproof/Heat-insulating
material
Non-flammable insulation
Turbo fan
Fan
Fan unit
Standard air flow
(High/Mid/Low)
Motor
(m3/h)
800
(730/680)
930
1,050
(830/790) (920/800)
1,320
1,680
2,040
(1,110/850) (1,300/1,070) (1,430/1,130)
60
(W)
90
Standard filter (Long life filter)
Air filter
Remote controller
Controller
Connecting
pipe
1,200
(920/820)
Gas side
(mm)
Liquid side
(mm)
O
/ 9.5
O
/ 15.9
O
/ 6.4
Drain port (Nominal dia. mm)
Sound pressure level (Note 2)
(dB(A))
(High/Mid/Low)
O
/ 12.7
O
/ 9.5
25 (Polyvinyl chloride tube)
30/29/27
31/29/27 32/29/28
PMV Kit
34/31/28
37/33/30 40/36/33 44/38/34
Not available
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the
actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB
Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB/6oC WB
9-1 -1
60Hz
Specifications (60Hz)
Model name
MMU-
AP0091H
AP0121H
AP0151H
AP0181H
AP0241H
AP0271H
AP0301H
AP0361H
AP0481H
(kW)
2.8/3.2
3.6/4.0
4.5/5.0
5.6/6.3
7.1/8.0
8.0/9.0
9.0/10.0
11.2/12.5
14.0/16.0
Cooling/Heating capacity (Note 1)
Power supply
1 phase 60Hz 220V (Separate power supply for indoor units is required.)
(A)
Running current
Electrical
characteristics Power consumption (kW)
Starting current
(A)
0.18
0.20
0.22
0.26
0.37
0.61
0.85
0.020
0.022
0.026
0.032
0.048
0.070
0.110
0.30
0.33
0.36
0.42
0.59
0.87
1.23
Main unit
Heat-insulating material attached Zinc hot dipping steel plate
RBC-U21PG (W) -E
Model
Appearance
Ceiling
panel
Main unit
Outer
dimension
Ceiling
panel
Panel color
Moon white (Munsell/2.5GY 9.0/0.5)
Height
(mm)
Width
(mm)
840
Depth
(mm)
840
Height
(mm)
35
Width
(mm)
950
Depth
(mm)
950
Main unit
(kg)
Ceiling panel
(kg)
256
319
22
20
23
28
Total weight
4.5
Heat exchanger
Finned tube
Soundproof/Heat-insulating
material
Non-flammable insulation
Turbo fan
Fan
Fan unit
Standard air flow
(High/Mid./Low)
Motor
(m3/h)
800
(730/680)
930
(830/790)
1,050
(920/800)
(W)
1,200
(920/820)
1,320
(1,110/850)
1,680
(1,300/1,070)
60
Air filter
2,040
(1,430/1,130)
90
Standard filter (Long life filter)
Controller
Remote controller
Gas side
Connecting
Liquid side
pipe
(mm)
O
/ 9.5
(mm)
O
/ 15.9
O
/ 12.7
O
/ 9.5
O
/ 6.4
Drain port (Nominal dia. mm)
Sound pressure level (Note 2)
(High/Mid./Low)
(dB(A))
25 (Polyvinyl chloride tube)
30/29/27
31/29/27
32/29/28
PMV Kit
34/31/28
37/33/30
40/36/33
44/38/34
Not available
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in
the actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions
Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
O
O
O
9-1 -2
O
O
O
9-1-2. Dimension
MMU-AP0091H to P0481H
Suction grille (Air suction port)
Electric parts box
Air discharge port (4-way)
35
860 to 910
ceiling open dimension
254.5
346.5
790 hanging bolt pitch
950
panel external dimension
415
o
381.6
723 hanging bolt pitch
Z
860 to 910
ceiling open dimension
950
panel external dimension
For branch duct knockout square hole O
/ 150
(2 positions at right side)
Refrigerant pipe
connecting port
840
(Gas)
250 70
Refrigerant pipe
Drain discharge port
270
connecting port
105
(Liquid)
Bottom face of ceiling
45
113
174
30
Bottom face of ceiling
Model
AP0091H to AP0301H
AP0361H to AP0481H
Bottom face
of ceiling
15 or more
Bottom face of ceiling
(NOTE)
As ABS is used for the drain discharge
port of the main unit, the vinyl chloride
paste cannot be used.
Use the flexible hose (Band fix)
included in the package.
Knockout for flesh air intake
For O
/ 100
Z view
Drain-up standing-up size
2.7
Wired remote controller
4
RBC-AMT31E
1000 or more
A
256
319
mm
B
120
183
1000 or more
1000 or more
Indoor unit
64
Stand-up
850 or less
57
.5
57 5
2
8
18
Stand-up
640 or less
360
15 or more
88
130
210
A
97 B
35
840
480
227
105
Hanging bolt
M10 or W3/8 local arrange
Space required for installation and servicing
200
Wireless remote controller kit
TCB-AX21U(W)-E2
16
Weekly timer application
120
RBC-AMT31E and RBC-EXW21E2
Check port
( 450)
Check port
( 450)
200
120
Simple wired remote controller
RBC-AS21E2
Note: All dimensions are in mm.
9-1 -3
9-1 -4
1 1
2 2
3 3
1 1
BLK
3 3
CN44 1
(BLN) 2
CN66 1
(WHI) 2
WHI
CN67
(BLK) 2 2
RED
1
CN304
(GRY) 2
3
: BLACK
: GRAY
: PINK
: ORANGE
: GREEN
Parts name
BLK
GRY
PNK
ORN
GRN
Fan motor
Indoor temp sensor
Temp sensor
Temp sensor
Temp sensor
Lover motor
Drain pump motor
Float switch
Drain control relay
Pulse Motor Valve
: RED
: WHITE
: YELLOW
: BLUE
: BROWN
Color identification
RED
WHI
YEL
BLU
BRN
Symbol
FM
TA
TC1
TCJ
TC2
LM1, LM2
DM
FS
RY302
PMV
R(L) S(N)
Closed end
connector
RED
WHI
Power supply
Single phase
220-240V 50Hz
220V 60Hz
Earth screw
Indoor unit
Flow selector
unit earth
screw
DM
CN68
(BLU)
Ð
+
CN61
(YEL)
T10 1 2 3 4 5 6
CN60
(WHI)
Power
supply
circuit
Outdoor unit
U1 U2
(Option)
3.
indicates the control P.C. board.
CN81
(BLK)
Wired remote
controller
1 2
1 2
CN1
(WHI)
BLK
A B
1 2 3 4 5
WHI
1 2 3 4 5 CN33
1 2 3 4 5 (WHI)
BLK
1 2
1 2
CN001
(WHI)
Adaptor for wireless
remote controller
WHI
WHI
BLK
1 2 3
1 2 3
CN41
(BLU)
1 2
1 2
CN40
(BLU)
TR
CN02
(BLU)
3 3
2 2
1 1
1 1
2 2
CN101
(BLK)
CN73
(RED)
CN80
(GRN)
1 2 3 4 5
MCC-1401
X Y
TA
1 Filter input
2
TC1
TC2
TCJ
1 EXCT
2
1
2 PNL
3
1 1
2 2
3 3
1 1
2 2
CN102
(RED)
CN100
(BRN)
1 1
2 2
CN104
(YEL)
CN20 CN70
(BLU) (WHI)
1 2 CN03
1 2 (RED)
Network
adaptor
P.C. board
FS
3
1 CN34
3 2 1 (RED)
CN01 1 2 Network adaptor
(WHI) 1 2 (Option)
1 2 3
1 2 3
CN309
(YEL)
Indoor control P.C. board
MCC-1402
DC20V
DC15V
DC12V
DC7V
U1 U2
1 2 3 4 5 6
Fuse
T3.15A
250V~
indicates the terminal block, the letter inside
indicates the terminal number.
(Fandrive)
1 2
CN32
(WHI)
~
~
Motor drive
circuit
1 2 3 4 5 6 CN82
1 2 3 4 5 6 (BLU)
2 . A dotted line and broken line indicate the wiring on site.
1.
1 2 3 4 5
CN50
(WHI)
P301
Fuse
T6.3A
250V~
RY303
RY302
5 4 3 2 1 CN334 1 2 3 4 5 CN333
5 4 3 2 1 (BLU) 1 2 3 4 5 (WHI)
6 4 3 1 2 5
6 4 3 1 2 5
LM1
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
LM2
1 2 3 4 5
1 2 3 4 5
BLU
BLU
BLK
PMV
BLK
FM
9-1-3. Wiring diagram
Model:MMU-AP0091H, AP0121H, AP0151H, AP0181H, AP0241H,
MMU-AP0271H, AP0301H, AP0361H, AP0481H, AP0561H
9-1-4. Sensible capacity table
(MMU-AP***H)
Cooling capacity
Unit
size
009
012
015
Outdoor
air temp.
°CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
16.0°CWB
23°CDB
TC
SHC
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
1.9
2.4
1.9
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.2
2.3
3.1
2.2
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.0
3.0
3.9
2.8
18.0°CWB
26°CDB
TC
SHC
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.6
2.0
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.4
2.5
3.4
2.4
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.3
3.1
4.2
3.0
TC : Total Capacity (kW) SHC : Sensible Heat Capacity (kW)
Indoor air temp.
19.0°CWB
20.0°CWB
22.0°CWB
24.0°CWB
27°CDB
28°CDB
30°CDB
32°CDB
TC
SHC
TC
SHC
TC
SHC
TC
SHC
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.7
2.1
2.8
2.1
3.0
2.0
3.1
2.0
2.7
2.0
2.8
2.0
2.9
2.0
3.1
1.9
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.5
2.5
3.6
2.4
3.8
2.4
4.0
2.4
3.5
2.4
3.6
2.4
3.8
2.3
3.9
2.3
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.4
3.1
4.5
3.1
4.8
3.1
5.0
3.0
4.3
3.0
4.4
3.0
4.7
3.0
4.9
2.9
9-1 -5
Cooling capacity (cont.)
Unit
size
018
024
027
Outdoor
air temp.
°CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
16.0°CWB
23°CDB
TC
SHC
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.0
3.6
4.9
3.5
6.4
4.6
6.4
4.6
6.4
4.6
6.4
4.6
6.4
4.6
6.4
4.6
6.4
4.6
6.4
4.6
6.4
4.6
6.4
4.6
6.4
4.6
6.4
4.6
6.4
4.6
6.4
4.6
6.3
4.5
6.2
4.4
7.3
5.2
7.3
5.2
7.3
5.2
7.3
5.2
7.3
5.2
7.3
5.2
7.3
5.2
7.3
5.2
7.3
5.2
7.3
5.2
7.3
5.2
7.3
5.2
7.3
5.2
7.3
5.2
7.1
5.1
7.0
4.9
18.0°CWB
26°CDB
TC
SHC
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.3
3.8
5.2
3.7
6.9
4.9
6.9
4.9
6.9
4.9
6.9
4.9
6.9
4.9
6.9
4.9
6.9
4.9
6.9
4.9
6.9
4.9
6.9
4.9
6.9
4.9
6.9
4.9
6.9
4.9
6.9
4.9
6.7
4.8
6.6
4.6
7.8
5.5
7.8
5.5
7.8
5.5
7.8
5.5
7.8
5.5
7.8
5.5
7.8
5.5
7.8
5.5
7.8
5.5
7.8
5.5
7.8
5.5
7.8
5.5
7.8
5.5
7.8
5.5
7.6
5.4
7.4
5.2
Indoor air temp.
19.0°CWB
27°CDB
TC
SHC
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.5
3.8
5.4
3.7
7.1
4.9
7.1
4.9
7.1
4.9
7.1
4.9
7.1
4.9
7.1
4.9
7.1
4.9
7.1
4.9
7.1
4.9
7.1
4.9
7.1
4.9
7.1
4.9
7.1
4.9
7.1
4.9
7.0
4.8
6.8
4.6
8.0
5.5
8.0
5.5
8.0
5.5
8.0
5.5
8.0
5.5
8.0
5.5
8.0
5.5
8.0
5.5
8.0
5.5
8.0
5.5
8.0
5.5
8.0
5.5
8.0
5.5
8.0
5.5
7.8
5.4
7.7
5.2
20.0°CWB
28°CDB
TC
SHC
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.7
3.8
5.5
3.7
7.3
4.9
7.3
4.9
7.3
4.9
7.3
4.9
7.3
4.9
7.3
4.9
7.3
4.9
7.3
4.9
7.3
4.9
7.3
4.9
7.3
4.9
7.3
4.9
7.3
4.9
7.3
4.9
7.2
4.8
7.0
4.6
8.2
5.5
8.2
5.5
8.2
5.5
8.2
5.5
8.2
5.5
8.2
5.5
8.2
5.5
8.2
5.5
8.2
5.5
8.2
5.5
8.2
5.5
8.2
5.5
8.2
5.5
8.2
5.5
8.1
5.4
7.9
5.2
9-1 -6
22.0°CWB
30°CDB
TC
SHC
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.0
3.8
5.9
3.6
7.7
4.9
7.7
4.9
7.7
4.9
7.7
4.9
7.7
4.9
7.7
4.9
7.7
4.9
7.7
4.9
7.7
4.9
7.7
4.9
7.7
4.9
7.7
4.9
7.7
4.9
7.7
4.9
7.6
4.8
7.4
4.6
8.7
5.4
8.7
5.4
8.7
5.4
8.7
5.4
8.7
5.4
8.7
5.4
8.7
5.4
8.7
5.4
8.7
5.4
8.7
5.4
8.7
5.4
8.7
5.4
8.7
5.4
8.7
5.4
8.5
5.3
8.4
5.1
24.0°CWB
32°CDB
TC
SHC
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.3
3.7
6.1
3.6
8.1
4.7
8.1
4.7
8.1
4.7
8.1
4.7
8.1
4.7
8.1
4.7
8.1
4.7
8.1
4.7
8.1
4.7
8.1
4.7
8.1
4.7
8.1
4.7
8.1
4.7
8.1
4.7
7.9
4.6
7.8
4.5
9.1
5.3
9.1
5.3
9.1
5.3
9.1
5.3
9.1
5.3
9.1
5.3
9.1
5.3
9.1
5.3
9.1
5.3
9.1
5.3
9.1
5.3
9.1
5.3
9.1
5.3
9.1
5.3
8.9
5.2
8.8
5.0
Cooling capacity (cont.)
Unit
size
030
036
048
Outdoor
air temp.
°CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
16.0°CWB
23°CDB
TC
SHC
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.0
5.7
7.8
5.5
10.2
7.3
10.2
7.3
10.2
7.3
10.2
7.3
10.2
7.3
10.2
7.3
10.2
7.3
10.2
7.3
10.2
7.3
10.2
7.3
10.2
7.3
10.2
7.3
10.2
7.3
10.2
7.3
10.0
7.1
9.8
6.8
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.5
9.1
12.2
8.7
18.0°CWB
26°CDB
TC
SHC
8.7
6.2
8.7
6.2
8.7
6.2
8.7
6.2
8.7
6.2
8.7
6.2
8.7
6.2
8.7
6.2
8.7
6.2
8.7
6.2
8.7
6.2
8.7
6.2
8.7
6.2
8.7
6.2
8.6
6.1
8.4
5.9
10.9
7.7
10.9
7.7
10.9
7.7
10.9
7.7
10.9
7.7
10.9
7.7
10.9
7.7
10.9
7.7
10.9
7.7
10.9
7.7
10.9
7.7
10.9
7.7
10.9
7.7
10.9
7.7
10.6
7.6
10.4
7.3
13.6
9.8
13.6
9.8
13.6
9.8
13.6
9.8
13.6
9.8
13.6
9.8
13.6
9.8
13.6
9.8
13.6
9.8
13.6
9.8
13.6
9.8
13.6
9.8
13.6
9.8
13.6
9.8
13.3
9.6
13.0
9.2
Indoor air temp.
19.0°CWB
27°CDB
TC
SHC
9.0
6.2
9.0
6.2
9.0
6.2
9.0
6.2
9.0
6.2
9.0
6.2
9.0
6.2
9.0
6.2
9.0
6.2
9.0
6.2
9.0
6.2
9.0
6.2
9.0
6.2
9.0
6.2
8.8
6.1
8.6
5.8
11.2
7.7
11.2
7.7
11.2
7.7
11.2
7.7
11.2
7.7
11.2
7.7
11.2
7.7
11.2
7.7
11.2
7.7
11.2
7.7
11.2
7.7
11.2
7.7
11.2
7.7
11.2
7.7
11.0
7.5
10.8
7.2
14.0
9.8
14.0
9.8
14.0
9.8
14.0
9.8
14.0
9.8
14.0
9.8
14.0
9.8
14.0
9.8
14.0
9.8
14.0
9.8
14.0
9.8
14.0
9.8
14.0
9.8
14.0
9.8
13.7
9.6
13.4
9.2
20.0°CWB
28°CDB
TC
SHC
9.3
6.2
9.3
6.2
9.3
6.2
9.3
6.2
9.3
6.2
9.3
6.2
9.3
6.2
9.3
6.2
9.3
6.2
9.3
6.2
9.3
6.2
9.3
6.2
9.3
6.2
9.3
6.2
9.1
6.1
8.9
5.8
11.5
7.7
11.5
7.7
11.5
7.7
11.5
7.7
11.5
7.7
11.5
7.7
11.5
7.7
11.5
7.7
11.5
7.7
11.5
7.7
11.5
7.7
11.5
7.7
11.5
7.7
11.5
7.7
11.3
7.5
11.1
7.2
14.4
9.8
14.4
9.8
14.4
9.8
14.4
9.8
14.4
9.8
14.4
9.8
14.4
9.8
14.4
9.8
14.4
9.8
14.4
9.8
14.4
9.8
14.4
9.8
14.4
9.8
14.4
9.8
14.1
9.6
13.8
9.2
9-1 -7
22.0°CWB
30°CDB
TC
SHC
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.6
6.0
9.4
5.8
12.2
7.6
12.2
7.6
12.2
7.6
12.2
7.6
12.2
7.6
12.2
7.6
12.2
7.6
12.2
7.6
12.2
7.6
12.2
7.6
12.2
7.6
12.2
7.6
12.2
7.6
12.2
7.6
12.0
7.5
11.7
7.2
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.0
9.5
14.6
9.1
24.0°CWB
32°CDB
TC
SHC
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.1
5.9
9.8
5.6
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.5
7.3
12.3
7.0
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
15.6
9.3
15.3
8.9
Heating capacity
Unit
size
009
012
015
Outdoor
air temp.
°CWB
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
SHC
2.0
2.1
2.3
2.3
2.5
2.6
2.7
2.9
3.0
3.1
3.2
3.3
3.3
3.3
3.3
3.3
2.5
2.7
2.8
2.9
3.1
3.3
3.4
3.6
3.7
3.9
4.0
4.2
4.2
4.2
4.2
4.2
3.1
3.3
3.6
3.7
3.9
4.1
4.3
4.5
4.7
4.8
5.0
5.2
5.2
5.2
5.2
5.2
SHC : Sensible Heat Capacity (kW)
Indoor air temp. °CDB
18.0
20.0
22.0
24.0
SHC
SHC
SHC
SHC
2.0
1.9
1.9
1.8
2.1
2.1
2.0
1.9
2.2
2.2
2.1
2.1
2.3
2.2
2.2
2.1
2.4
2.4
2.3
2.3
2.6
2.5
2.4
2.4
2.7
2.6
2.6
2.5
2.8
2.7
2.7
2.6
2.9
2.9
2.8
2.7
3.0
3.0
2.9
2.8
3.2
3.1
3.0
2.9
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
2.5
2.4
2.3
2.3
2.6
2.6
2.5
2.4
2.8
2.7
2.7
2.6
2.9
2.8
2.7
2.7
3.0
3.0
2.9
2.8
3.2
3.1
3.0
3.0
3.3
3.3
3.2
3.1
3.5
3.4
3.3
3.3
3.7
3.6
3.5
3.4
3.8
3.7
3.6
3.5
3.9
3.9
3.8
3.7
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
3.1
3.0
2.9
2.9
3.3
3.2
3.1
3.0
3.5
3.4
3.3
3.2
3.6
3.5
3.4
3.3
3.8
3.7
3.6
3.5
4.0
3.9
3.8
3.7
4.2
4.1
4.0
3.9
4.4
4.3
4.2
4.1
4.6
4.5
4.4
4.2
4.7
4.6
4.5
4.4
4.9
4.8
4.7
4.6
5.1
5.0
4.9
4.8
5.1
5.0
4.9
4.8
5.1
5.0
4.9
4.8
5.1
5.0
4.9
4.8
5.1
5.0
4.9
4.8
9-1 -8
Heating capacity (cont.)
Unit
size
018
024
027
Outdoor
air temp.
°CWB
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
SHC
3.9
4.2
4.5
4.6
4.9
5.1
5.4
5.6
5.9
6.1
6.3
6.6
6.6
6.6
6.6
6.6
5.0
5.3
5.7
5.8
6.2
6.5
6.8
7.1
7.4
7.7
8.0
8.3
8.3
8.3
8.3
8.3
5.6
6.0
6.4
6.6
7.0
7.3
7.7
8.0
8.4
8.7
9.0
9.4
9.4
9.4
9.4
9.4
Indoor air temp. °CDB
18.0
20.0
22.0
SHC
SHC
SHC
3.9
3.8
3.7
4.1
4.0
3.9
4.4
4.3
4.2
4.5
4.4
4.3
4.8
4.7
4.6
5.0
4.9
4.8
5.3
5.2
5.0
5.5
5.4
5.3
5.8
5.6
5.5
6.0
5.9
5.7
6.2
6.1
5.9
6.4
6.3
6.1
6.4
6.3
6.1
6.4
6.3
6.1
6.4
6.3
6.1
6.4
6.3
6.1
4.9
4.8
4.7
5.2
5.1
5.0
5.6
5.5
5.3
5.7
5.6
5.5
6.1
5.9
5.8
6.4
6.2
6.1
6.7
6.6
6.4
7.0
6.9
6.7
7.3
7.1
7.0
7.6
7.4
7.3
7.9
7.7
7.5
8.2
8.0
7.8
8.2
8.0
7.8
8.2
8.0
7.8
8.2
8.0
7.8
8.2
8.0
7.8
5.5
5.4
5.3
5.9
5.8
5.6
6.3
6.1
6.0
6.5
6.3
6.2
6.8
6.7
6.5
7.2
7.0
6.9
7.5
7.4
7.2
7.9
7.7
7.5
8.2
8.0
7.8
8.5
8.4
8.2
8.9
8.7
8.5
9.2
9.0
8.8
9.2
9.0
8.8
9.2
9.0
8.8
9.2
9.0
8.8
9.2
9.0
8.8
24.0
SHC
3.6
3.8
4.1
4.2
4.4
4.7
4.9
5.1
5.3
5.6
5.8
6.0
6.0
6.0
6.0
6.0
4.6
4.9
5.2
5.3
5.6
5.9
6.2
6.5
6.8
7.1
7.3
7.6
7.6
7.6
7.6
7.6
5.1
5.5
5.8
6.0
6.3
6.7
7.0
7.3
7.6
7.9
8.3
8.6
8.6
8.6
8.6
8.6
9-1 -9
Heating capacity (cont.)
Unit
size
030
036
048
Outdoor
air temp.
°CWB
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
SHC
6.3
6.7
7.1
7.3
7.7
8.1
8.5
8.9
9.3
9.7
10.0
10.4
10.4
10.4
10.4
10.4
7.8
8.3
8.9
9.1
9.7
10.2
10.7
11.1
11.6
12.1
12.6
13.0
13.0
13.0
13.0
13.0
10.0
10.7
11.4
11.7
12.4
13.0
13.6
14.3
14.9
15.5
16.1
16.7
16.7
16.7
16.7
16.7
Indoor air temp. °CDB
18.0
20.0
22.0
SHC
SHC
SHC
6.1
6.0
5.9
6.6
6.4
6.3
7.0
6.8
6.7
7.2
7.0
6.9
7.6
7.4
7.2
8.0
7.8
7.6
8.4
8.2
8.0
8.8
8.6
8.4
9.1
8.9
8.7
9.5
9.3
9.1
9.9
9.7
9.4
10.2
10.0
9.8
10.2
10.0
9.8
10.2
10.0
9.8
10.2
10.0
9.8
10.2
10.0
9.8
7.7
7.5
7.3
8.2
8.0
7.8
8.7
8.5
8.3
9.0
8.8
8.6
9.5
9.3
9.1
10.0
9.8
9.5
10.5
10.2
10.0
10.9
10.7
10.5
11.4
11.2
10.9
11.9
11.6
11.3
12.3
12.1
11.8
12.8
12.5
12.2
12.8
12.5
12.2
12.8
12.5
12.2
12.8
12.5
12.2
12.8
12.5
12.2
9.8
9.6
9.4
10.5
10.3
10.0
11.1
10.9
10.7
11.5
11.2
11.0
12.1
11.9
11.6
12.8
12.5
12.2
13.4
13.1
12.8
14.0
13.7
13.4
14.6
14.3
14.0
15.2
14.9
14.5
15.8
15.4
15.1
16.3
16.0
15.6
16.3
16.0
15.6
16.3
16.0
15.6
16.3
16.0
15.6
16.3
16.0
15.6
24.0
SHC
5.7
6.1
6.5
6.7
7.0
7.4
7.8
8.1
8.5
8.8
9.2
9.5
9.5
9.5
9.5
9.5
7.2
7.6
8.1
8.3
8.8
9.3
9.7
10.2
10.6
11.0
11.5
11.9
11.9
11.9
11.9
11.9
9.1
9.7
10.4
10.7
11.3
11.9
12.4
13.0
13.6
14.1
14.7
15.2
15.2
15.2
15.2
15.2
9-1 -10
9-1-5. Air throw distance chart
MMU-AP0091H, AP0121H
MMU-AP0151H
2.8m
2.7m
0.7m/s
2
0.3m/s
2
0.5m/s
0.5m/s
0.7m/s
1
1
0.3m/s
0
0
1
2
3
4
1
2
3
4
5m
5m
MMU-AP0181H
MMU-AP0241H,AP0271H
3.6m
3
2.8m
0.7m/s
2
0.7m/s
1
1
2
3
4
0.3m/s
1
0.3m/s
0
0.5m/s
2
0.5m/s
0
5m
1
2
3
4
5m
MMU-AP0301H
MMU-A0361H
3.6m
3
3.6m
2
0.7m/s
3
0.7m/s
0.5m/s
2
0.5m/s
0.3m/s
1
1
0.3m/s
0
0
1
2
3
4
1
2
3
4
5m
5m
MMU-AP0561H
3.6m
3
MMU-A0481H
0.7m/s
3.6m
3
0.3m/s
0.5m/s
2
1
0.3m/s
1
0
0.5m/s
2
0.7m/s
1
2
3
4
5m
0
9-1 -11
1
2
3
4
5m
9-1-6. Sound characteristics (NC-Curve)
Sound level values shown are based on a measurement in a non resound room.
Microphone
Octave band sound pressure level (dB)
MMU-AP0091H, AP0121H
Fan Tap
H
M
L
Sound pressure
level (dB(A))
30
29
27
Audibility limits of
continuous white level
Octave band frequency (Hz)
MMU-AP0181H
Fan Tap
H
M
L
Fan Tap
H
M
L
Sound pressure
level (dB(A))
31
29
27
Sound pressure
level (dB(A))
32
29
28
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
MMU-AP0151H
Audibility limits of
continuous white level
Octave band frequency (Hz)
Octave band frequency (Hz)
Octave band sound pressure level (dB)
MMU-AP0241H, AP0271H
Fan Tap
H
M
L
Sound pressure
level (dB(A))
34
31
28
Audibility limits of
continuous white level
Audibility limits of
continuous white level
Octave band frequency (Hz)
9-1 -12
Sound level values shown are based on a measurement in a non resound room.
MMU-AP0301H
37
M
33
L
30
Octave band sound pressure level (dB)
Sound pressure
level (dB(A))
Octave band sound pressure level (dB)
MMU-AP0361H
H
Fan T
ap
Tap
Audibility limits of
continuous white level
Fan T
ap
Tap
H
M
L
Sound pressure
level (dB(A))
40
36
33
Audibility limits of
continuous white level
Octave band frequency (Hz)
MMU-AP0481H
Octave band frequency (Hz)
MMU-AP0561H
M
L
Fan T
ap
Tap
H
M
L
Sound pressure
level (dB(A))
44
38
34
Sound pressure
level (dB(A))
45
48
34
Audibility limits of
continuous white level
Octave band sound pressure level (dB)
H
Octave band sound pressure level (dB)
Fan T
ap
Tap
Audibility limits of
continuous white level
Octave band frequency (Hz)
Octave band frequency (Hz)
9-1 -13
9-1-7. Accessories
Apperarance
Standard accessories
Part name
Qty
Shape
Use
Part name
Qty
Shape
Use
Installation
Manual
2
(Be sure to hand over to
customer)
Heat
insulator
1
For heat insulating of drain
connecting section
Heat
insulating
pipe
2
For heat insulating of pipe
connecting section
Washer
8
For hanging down unit
Installation
pattern
1
For confirmation of ceiling
opening and main unit
position
Hose band
1
For connecting drain pipe
Installation
gauge
2
For positioning of ceiling
position
(united with installation
pattern)
Flexible
hose
1
For centering the drain pipe
Pattern
fixing screw
4
For attaching pattern
Heat
insulator
1
For sealing the wire
connection opening
M5 x 16
Remote controller
Model Name
Wired remote controller
RBC-AMT31E
Simple wired remote controller
Wireless remote controller kit
RBC-AS21E2
TCB-AX21U(W)-E2
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
Central remote controller
TCB-SC642TLE2
ON-OFF controller
TCB-CC163TLE2
9-1 -14
Optional accessories
Air discharge direction kit
Auxiliary fresh air Flange
TCB-FF101URE2
Super Long Life Filter
TCB-LF1601UE2
TCB-BC1601UE
High Efficiency Filter 65
TCB-UFM1601UE
High Efficiency Filter 90
TCB-UFH1601UE
Fresh air inlet Box
Fresh air and Filter Chamber
TCB-GB1601UE2
TCB-GFC1601UE2
Spacer for height adjustment
TCB-SP1601UE
Ceiling panel
RBC-U21PG(W)-E2
Name
Model name
Note
Ceiling panel
RBC-U21PG(W)-E2
Super Long Life Filter
TCB-LF1601UE2
Dust collecting effect :50%
(Weight method)
Use with TCB-GFC1601UE2
High Efficiency Filter 65
TCB-UFM1601UE
Dust collecting effect :65%
(NBS Colorimentric method)
Use with TCB-GFC1601UE2
High Efficiency Filter 90
TCB-UFH1601UE
Dust collecting effect :90%
(NBS Colorimentric method)
Use with TCB-GFC1601UE2
Fresh Air Inlet Box
TCB-GB1601UE2
For fresh air intake by using the knockout hole of
fresh air and filter chamber. (dia=100mm)
*Not valid in combination with TCB-FF101URE
Use with TCB-GFC1601UE2
Frech Air and Filter Chamber
TCB-GFC1601UE2
For fresh air intake and installing high efficiency
filter or super long filter
Auxiliary Fresh Air Flange
TCB-FF101URE2
For easy fresh air intake by using the knockout
hole of indoor unit.(dia=100mm)
*Not valid in combination with TCB-GB1601UE2
Spacer for Height Adjustment
TCB-SP1601UE
Height=500mm
Air Discharge Direction Kit
TCB-BC1601UE
Air direction charge by cutting off air discharge
port (3pcs)
Required accessory
9-1 -15
9-2-1. Specifications
50Hz
Specifications (50Hz)
Model name
Cooling/Heating capacity (Note 1)
MMU-
AP0071MH
AP0091MH
AP0121MH
AP0151MH
AP0181MH
(kW)
2.2/2.5
2.8/3.2
3.6/4.0
4.5/5.0
5.6/6.3
Power supply
Electrical
characteristics
1 phase 50Hz 230V (220-240V) (Separate power supply for indoor units is required.)
(A)
0.28
0.30
0.31
0.34
0.42
Power consumption (kW)
0.034
0.036
0.038
0.041
0.052
Starting current
0.49
0.52
0.54
0.59
0.73
Running current
(A)
Main unit
Appearance
Ceiling
panel
Zinc hot dipping steel plate *Heat-insulating material attached to only upper plate
Model
RBC-UM11PG(W)E
Panel color
Moon white (Munsell/2.5GY 9.0/0.5)
Height (mm)
268
Width (mm)
575
Depth (mm)
575
Height (mm)
27
Width (mm)
700
Depth (mm)
700
Main unit
(kg)
17
Ceiling panel
(kg)
3
Main unit
Outer
dimension
Ceiling
panel
Total weigh
Finned tube
Heat exchanger
Soundproof/Heat-insulating
material
Non-flammble insulation
Turbo fan
Fan
Fan unit
Standard air flow
(High/Mid/Low)
Motor
(m3/h)
552/462/378
570/468/378
594/504/402
Long life filter
Controller
RBC-AMT31E
Gas side
O
/ 9.5
(mm)
O
/ 12.7
O
/ 6.4
(mm)
25 (Polyvinyl choride tube)
Drain port (Nominal dia. mm)
Sound pressure level (Note 2)
(dB(A))
(High/Mid/Low)
762/642/522
60
(W)
Air filter
Connecting
Liquid side
pipe
660/552/468
36/32/28
37/33/28
37/33/29
40/35/30
44/39/34
Available
PMV Kit
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the
actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB
Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB/6oC WB
9-2 -1
60Hz
Specifications (60Hz)
Model name
Cooling/Heating capacity (Note 1)
MMU-
AP0071MH
AP0091MH
AP0121MH
AP0151MH
AP0181MH
(kW)
2.2/2.5
2.8/3.2
3.6/4.0
4.5/5.0
5.6/6.3
Power supply
Electrical
characteristics
1 phase 60Hz 220V (Separate power supply for indoor units is required.)
(A)
0.27
0.29
0.30
0.33
0.41
Power consumption
(kW)
0.034
0.036
0.038
0.041
0.052
Starting current
(A)
0.49
0.52
0.54
0.59
0.73
Running current
Main unit
Appearance
Ceiling
panel
Zinc hot dipping steel plate *Heat-insulating material attached to only upper plate
Model
RBC-UM11PG(W)E
Panel color
Moon white (Munsell/2.5GY 9.0/0.5)
Height (mm)
268
Width (mm)
575
Depth (mm)
575
Height (mm)
27
Width (mm)
700
Depth (mm)
700
Main unit
(kg)
17
Ceiling panel
(kg)
3
Main unit
Outer
dimension
Ceiling
panel
Total weigh
Finned tube
Heat exchanger
Soundproof/Heat-insulating
material
Non-flammble insulation
Turbo fan
Fan
Fan unit
Standard air flow
(High/Mid/Low)
Motor
(m3/h)
552/462/378
570/468/378
594/504/402
Long life filter
Controller
RBC-AMT31E
Gas side
(mm)
Liquid side
(mm)
O
/ 9.5
O
/ 12.7
O
/ 6.4
23 (Polyvinyl choride tube)
Drain port (Nominal dia. mm)
Sound pressure level (Note 2)
(dB(A))
(High/Mid/Low)
762/642/522
60
(W)
Air filter
Connecting
pipe
660/552/468
36/32/28
37/33/28
37/33/29
PMV Kit
40/35/30
44/39/34
Available
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in
the actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions
Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
O
O
O
9-2 -2
O
O
O
9-2-2. Dimension
MMU-AP0071MH, AP0091MH, AP0121MH, AP0151MH, AP0181MH
4-way air Discharge Cassete Type
Arialb1i0c0p34;TOSHIBA CARRIER CORPORATION
177
525 hanging bolt pitch
595 to 660 ceiling open dimension
700 Panel external dimension
214 105
42
148
145.5
134
63
21
158
Bottom face of ceiling
120
Ceiling panel
142
268
O
/ 162
55
93
193.5
Wiring connection port
For branch duct knockout square hole O
/ 150
64
Drain discharge port
256
105 70.5
97.5
Hanging bolt
M10 or W3/8 local arrange
220.5
Refrigerant pipe (Gas)
0151, 0181MH................. O
/ 12.7
0071, 0091, 0121MH....... O
/ 9.5
27
MMU-AP0151MH
MMU-AP0181MH
149
64
29
368.5
525 hanging bolt pitch
331.5
Model name
MMU-AP0071MH
MMU-AP0091MH
595 to 660 ceiling open dimension
575 unit external dimension
142
Knockout for
flesh air intake O
/ 100
MMU-AP0121MH
190.5
175
235
320.5
575 unit external dimension
105
235
Electric
parts box
700 Panel external dimension
Bottom face
of ceiling O
/ 162
Refrigerant pipe (Liquid) O
/ 6.4
207
70.5
For bracch duct
knockout square hole O
/ 150
145.5
105 93
Bottom face of ceiling
1000 or more
15 or more
15 or more
Bottom face
Drain-up standing-up size of ceiling
1000 or more
595 to 660 ceiling open dimension
Indoor unit
200
Stand-up
827.5 or less
Stand-up
850 or less
300
(NOTE)
As ABS is used for the drain discharge port of the main unit,
the vinyl chloride paste cannot be used.
Use the flexible hose (Band fix)
included in the package.
Check port
( 450)
1000 or more
595 to 660 ceiling open dimension
Obustacle
Space required for installation and servicing
Wired remote controller
RBC-AMT31E
Wireless remote controller kit
TCB-AX21E2
Simple wired remote controller
RBC-AS21E2
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
9-2 -3
Note: All dimensions are in mm.
9-2-3. Wiring diagram
Model:MMU-AP007MH, AP0091MH, AP0121MH, AP0151MH, AP0181MH
9-2 -4
9-2-4. Sensible capacity table
(MMU-AP***MH)
Cooling capacity
Unit
size
007
009
012
Outdoor
air temp.
CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
14.0CWB
20CDB
TC
SHC
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.8
1.5
1.7
1.5
1.7
1.4
2.3
1.8
2.3
1.8
2.3
1.8
2.3
1.8
2.3
1.8
2.3
1.8
2.3
1.8
2.3
1.8
2.3
1.8
2.3
1.8
2.3
1.8
2.3
1.8
2.3
1.8
2.3
1.8
2.2
1.7
2.2
1.7
3.0
2.2
3.0
2.2
3.0
2.2
3.0
2.2
3.0
2.2
3.0
2.2
3.0
2.2
3.0
2.2
3.0
2.2
3.0
2.2
3.0
2.2
3.0
2.2
3.0
2.2
3.0
2.2
2.9
2.1
2.8
2.1
16.0CWB
23CDB
TC
SHC
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
1.9
1.6
1.9
1.5
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.8
2.4
1.8
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.2
2.3
3.1
2.2
TC:Total capacity[kW] SHC:Sensible capacity[kW]
Indoor air temp.
18.0CWB
19.0CWB
20.0CWB
22.0CWB
24.0CWB
26CDB
27CDB
28CDB
30CDB
32CDB
TC
SHC
TC
SHC
TC
SHC
TC
SHC
TC
SHC
2.1
1.7
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.1
1.7
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.1
1.7
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.1
1.7
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.1
1.7
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.1
1.7
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.1
1.7
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.1
1.7
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.1
1.7
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.1
1.7
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.1
1.7
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.1
1.7
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.1
1.7
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.1
1.7
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.1
1.7
2.1
1.6
2.2
1.6
2.3
1.6
2.4
1.6
2.0
1.6
2.1
1.6
2.1
1.6
2.3
1.6
2.4
1.5
2.7
2.0
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.7
2.0
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.7
2.0
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.7
2.0
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.7
2.0
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.7
2.0
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.7
2.0
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.7
2.0
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.7
2.0
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.7
2.0
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.7
2.0
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.7
2.0
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.7
2.0
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.7
2.0
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.6
1.9
2.7
1.9
2.8
1.9
3.0
1.9
3.1
1.9
2.6
1.9
2.6
1.9
2.7
1.9
2.9
1.9
3.0
1.8
3.5
2.5
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.5
2.5
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.5
2.5
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.5
2.5
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.5
2.5
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.5
2.5
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.5
2.5
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.5
2.5
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.5
2.5
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.5
2.5
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.5
2.5
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.5
2.5
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.5
2.5
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.5
2.5
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.4
2.4
3.5
2.4
3.6
2.4
3.8
2.4
4.0
2.3
3.3
2.4
3.4
2.4
3.5
2.4
3.7
2.3
3.9
2.3
9-2 -5
Cooling capacity (cont.)
Unit
size
015
018
Outdoor
air temp.
CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
14.0CWB
20CDB
TC
SHC
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.7
2.7
3.6
2.7
3.5
2.6
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.5
3.1
4.3
3.0
16.0CWB
23CDB
TC
SHC
4.1
2.9
4.1
2.9
4.1
2.9
4.1
2.9
4.1
2.9
4.1
2.9
4.1
2.9
4.1
2.9
4.1
2.9
4.1
2.9
4.1
2.9
4.1
2.9
4.1
2.9
4.1
2.9
4.0
2.8
3.8
2.8
5.1
3.4
5.1
3.4
5.1
3.4
5.1
3.4
5.1
3.4
5.1
3.4
5.1
3.4
5.1
3.4
5.1
3.4
5.1
3.4
5.1
3.4
5.1
3.4
5.1
3.4
5.1
3.4
4.9
3.3
4.8
3.2
18.0CWB
26CDB
TC
SHC
4.4
3.1
4.4
3.1
4.4
3.1
4.4
3.1
4.4
3.1
4.4
3.1
4.4
3.1
4.4
3.1
4.4
3.1
4.4
3.1
4.4
3.1
4.4
3.1
4.4
3.1
4.4
3.1
4.2
3.0
4.1
2.9
5.4
3.6
5.4
3.6
5.4
3.6
5.4
3.6
5.4
3.6
5.4
3.6
5.4
3.6
5.4
3.6
5.4
3.6
5.4
3.6
5.4
3.6
5.4
3.6
5.4
3.6
5.4
3.6
5.3
3.5
5.1
3.4
Indoor air temp.
19.0CWB
27CDB
TC
SHC
4.5
3.1
4.5
3.1
4.5
3.1
4.5
3.1
4.5
3.1
4.5
3.1
4.5
3.1
4.5
3.1
4.5
3.1
4.5
3.1
4.5
3.1
4.5
3.1
4.5
3.1
4.5
3.1
4.4
3.0
4.2
2.9
5.6
3.6
5.6
3.6
5.6
3.6
5.6
3.6
5.6
3.6
5.6
3.6
5.6
3.6
5.6
3.6
5.6
3.6
5.6
3.6
5.6
3.6
5.6
3.6
5.6
3.6
5.6
3.6
5.4
3.5
5.3
3.4
9-2 -6
20.0CWB
28CDB
TC
SHC
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.6
3.1
4.5
3.0
4.4
2.9
5.8
3.6
5.8
3.6
5.8
3.6
5.8
3.6
5.8
3.6
5.8
3.6
5.8
3.6
5.8
3.6
5.8
3.6
5.8
3.6
5.8
3.6
5.8
3.6
5.8
3.6
5.8
3.6
5.6
3.5
5.4
3.4
22.0CWB
30CDB
TC
SHC
4.9
3.1
4.9
3.1
4.9
3.1
4.9
3.1
4.9
3.1
4.9
3.1
4.9
3.1
4.9
3.1
4.9
3.1
4.9
3.1
4.9
3.1
4.9
3.1
4.9
3.1
4.9
3.1
4.7
3.0
4.6
2.9
6.1
3.6
6.1
3.6
6.1
3.6
6.1
3.6
6.1
3.6
6.1
3.6
6.1
3.6
6.1
3.6
6.1
3.6
6.1
3.6
6.1
3.6
6.1
3.6
6.1
3.6
6.1
3.6
5.9
3.5
5.7
3.4
24.0CWB
32CDB
TC
SHC
5.1
3.0
5.1
3.0
5.1
3.0
5.1
3.0
5.1
3.0
5.1
3.0
5.1
3.0
5.1
3.0
5.1
3.0
5.1
3.0
5.1
3.0
5.1
3.0
5.1
3.0
5.1
3.0
5.0
2.9
4.8
2.8
6.4
3.5
6.4
3.5
6.4
3.5
6.4
3.5
6.4
3.5
6.4
3.5
6.4
3.5
6.4
3.5
6.4
3.5
6.4
3.5
6.4
3.5
6.4
3.5
6.4
3.5
6.4
3.5
6.2
3.4
6.0
3.3
Heating capacity
Unit
size
007
009
012
Outdoor
air temp.
°CWB
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
SHC
1.6
1.7
1.8
1.8
1.9
2.0
2.1
2.2
2.3
2.4
2.5
2.6
2.6
2.6
2.6
2.6
2.0
2.1
2.3
2.3
2.5
2.6
2.7
2.9
3.0
3.1
3.2
3.3
3.3
3.3
3.3
3.3
2.5
2.7
2.8
2.9
3.1
3.3
3.4
3.6
3.7
3.9
4.0
4.2
4.2
4.2
4.2
4.2
SHC : Sensible Heat Capacity (kW)
Indoor air temp. °CDB
18.0
20.0
22.0
24.0
SHC
SHC
SHC
SHC
1.5
1.5
1.5
1.4
1.6
1.6
1.6
1.5
1.7
1.7
1.7
1.6
1.8
1.8
1.7
1.7
1.9
1.9
1.8
1.8
2.0
2.0
1.9
1.9
2.1
2.0
2.0
1.9
2.2
2.1
2.1
2.0
2.3
2.2
2.2
2.1
2.4
2.3
2.3
2.2
2.5
2.4
2.4
2.3
2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.0
1.9
1.9
1.8
2.1
2.1
2.0
1.9
2.2
2.2
2.1
2.1
2.3
2.2
2.2
2.1
2.4
2.4
2.3
2.3
2.6
2.5
2.4
2.4
2.7
2.6
2.6
2.5
2.8
2.7
2.7
2.6
2.9
2.9
2.8
2.7
3.0
3.0
2.9
2.8
3.2
3.1
3.0
2.9
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
2.5
2.4
2.3
2.3
2.6
2.6
2.5
2.4
2.8
2.7
2.7
2.6
2.9
2.8
2.7
2.7
3.0
3.0
2.9
2.8
3.2
3.1
3.0
3.0
3.3
3.3
3.2
3.1
3.5
3.4
3.3
3.3
3.7
3.6
3.5
3.4
3.8
3.7
3.6
3.5
3.9
3.9
3.8
3.7
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
9-2 -7
Heating capacity (cont.)
Unit
size
015
018
Outdoor
air temp.
°CWB
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
SHC
3.1
3.3
3.6
3.7
3.9
4.1
4.3
4.5
4.7
4.8
5.0
5.2
5.2
5.2
5.2
5.2
3.9
4.2
4.5
4.6
4.9
5.1
5.4
5.6
5.9
6.1
6.3
6.6
6.6
6.6
6.6
6.6
Indoor air temp. °CDB
18.0
20.0
22.0
SHC
SHC
SHC
3.1
3.0
2.9
3.3
3.2
3.1
3.5
3.4
3.3
3.6
3.5
3.4
3.8
3.7
3.6
4.0
3.9
3.8
4.2
4.1
4.0
4.4
4.3
4.2
4.6
4.5
4.4
4.7
4.6
4.5
4.9
4.8
4.7
5.1
5.0
4.9
5.1
5.0
4.9
5.1
5.0
4.9
5.1
5.0
4.9
5.1
5.0
4.9
3.9
3.8
3.7
4.1
4.0
3.9
4.4
4.3
4.2
4.5
4.4
4.3
4.8
4.7
4.6
5.0
4.9
4.8
5.3
5.2
5.0
5.5
5.4
5.3
5.8
5.6
5.5
6.0
5.9
5.7
6.2
6.1
5.9
6.4
6.3
6.1
6.4
6.3
6.1
6.4
6.3
6.1
6.4
6.3
6.1
6.4
6.3
6.1
24.0
SHC
2.9
3.0
3.2
3.3
3.5
3.7
3.9
4.1
4.2
4.4
4.6
4.8
4.8
4.8
4.8
4.8
3.6
3.8
4.1
4.2
4.4
4.7
4.9
5.1
5.3
5.6
5.8
6.0
6.0
6.0
6.0
6.0
9-2 -8
9-2-5. Air throw distance chart
Air Speed Distribution
MMU-AP0071MH
MMU-AP0091MH
2.7m
2.7m
0.7m/s
0.7m/s
2
2
0.5m/s
0.5m/s
1
1
0.3m/s
0.3m/s
0
1
2
4
3
0
5m
MMU-AP0121MH
1
2
3
4
5m
4
5m
MMU-AP0151MH
2.7m
2.9m
0.7m/s
3
0.7m/s
2
2
0.5m/s
1
1
0.3m/s
0
1
2
4
3
0.5m/s
0.3m/s
5m
0
MMU-AP0181MH
3.2m
1
2
3
MMU-AP0151MH,MMU-AP0181MH
(High ceiling mode)
3.2m
3
2
1
0
1
2
3
0.7m/s
3
0.5m/s
2
0.3m/s
1
4
5m
0.7m/s
0.5m/s
0.3m/s
0
9-2 -9
1
2
3
4
5m
9-2-6. Sound characteristics (NC-Curve)
MMU-AP0071MH
Octave band sound pressure level (dB)
[Measuring location]
1.5m
Microphone
Fan Tap
H
M
L
Sound pressure
level (dB(A))
36
32
28
70
60
50
NC-50
40
NC-40
H
30
NC-30
M
L
20
NC-20
Approximate threshold of
hearing for continuous noise
10
63
125
250
500
1000
2000
4000
8000
Octave band frequency (Hz)
MMU-AP0121MH
H
M
L
Fan Tap
H
M
L
Sound pressure
level (dB(A))
37
33
28
Sound pressure
level (dB(A))
37
33
29
70
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
MMU-AP0091MH
Fan Tap
60
50
NC-50
40
NC-40
H
M
L
30
NC-30
20
NC-20
Approximate threshold of
hearing for continuous noise
10
63
125
250
500
1000
2000
4000
70
60
50
NC-50
40
NC-40
H
M
L
30
20
NC-20
Approximate threshold of
hearing for continuous noise
10
63
8000
125
Octave band frequency (Hz)
1000
2000
M
L
Fan Tap
H
M
L
Sound pressure
level (dB(A))
40
35
30
Sound pressure
level (dB(A))
44
39
34
60
50
NC-50
40
H
M
L
30
NC-40
NC-30
20
NC-20
Approximate threshold of
hearing for continuous noise
250
500
1000
4000
8000
MMU-AP0181MH
H
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
500
Fan Tap
70
125
250
Octave band frequency (Hz)
MMU-AP0151MH
10
63
NC-30
2000
4000
8000
Octave band frequency (Hz)
70
60
50
NC-50
H
M
40
NC-40
L
NC-30
30
20
NC-20
Approximate threshold of
hearing for continuous noise
10
63
125
250
500
1000
2000
Octave band frequency (Hz)
9-2 -10
4000
8000
9-2-7. Accessories
Apperarance
Standard accessories
Part name
Qty
Use
Shape
Installation Manual
1
(Be sure to hand over to customer)
Heat insulating pipe
2
For heat insulating of pipe connecting section
Installation pattern
1
For confirmation of ceiling opening and main unit position
Installation gauge
2
For positioning of ceiling position
(united with installation pattern)
Pattern fixing screw
4
Heat insulator
1
For heat insulating of drain connecting section
Washer
8
For hanging down unit
Hose band
1
For connecting drain pipe
Flexible hose
1
For centering the drain pipe
Heat insulator
1
For sealing the wire connection opening
M5 x 16
For attaching pattern
Remote controller
Model Name
Wired remote controller
RBC-AMT31E
Simple wired remote controller
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E2
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
Central remote controller
TCB-SC642TLE2
ON-OFF controller
TCB-CC163TLE2
9-2 -11
Optional accessories
Auxiliary fresh air Flange
Air discharge direction kit
TCB-FF101URE2
Fresh air inlet Box
*********
Fresh air Chamber
*********
Spacer for height adjustment
*********
Ceiling panel
RBC-UM11PG(W)E
Name
Model name
Note
Ceiling panel
RBC-UM11PG(W)E
Auxiliary Fresh Air Flange
TCB-FF101URE2
Frech Air and Filter Chamber
TBD
Fresh air inlet Box
TBD
Spacer for height adjustment
TBD
Air discharge direction kit
TBD
Required accessory
For easy fresh air intake by using the knockout
hole of indoor unit.(dia=100mm)
This product is scheduled to go on sale
9-2 -12
9-3-1. Specifications
50Hz
Specifications (50Hz)
Model name
MMU- AP0071WH
Cooling/Heating capacity (Note 1)
Power supply
Electrical
characteristics
Running current
2.2/2.5
AP0121WH
AP0151WH
AP0181WH
AP0241WH
AP0271WH
AP0301WH
2.8/3.2
3.6/4.0
4.5/5.0
5.6/6.3
7.1/8.0
8.0/9.0
9.0/10.0
(kW) 1 phase 50Hz 230V (220-240V) (Separate power supply for indoor units is required.)
(A)
0.31
0.32
0.46
0.47
Power consumption (kW)
0.070
0.072
0.105
0.106
99
98
0.89
0.98
Power factor
(%)
Starting current
(A)
Main unit
Appearance
AP0091WH
Ceiling
panel
Main unit
Outer
dimension
Ceiling
panel
97
0.47
0.60
Heat-insulating material attached Zinc hot dipping steel plate
RBC-UW136PG
Model
RBC-UW266PG
Panel color
Light ivory (Munsell 10Y 9/0.5)
Height (mm)
398
Width (mm)
830
1,350
Depth (mm)
550
Height (mm)
8
Width (mm)
1,000
1,520
Depth (mm)
650
Main unit
(kg)
33
Ceiling panel
(kg)
8
44
48
Total weigh
11
Finned tube
Heat exchanger
Soundproof/Heat-insulating
material
Non-flammable insulation
Centrifugal fan
Fan
Fan unit
Standard air flow
(High/Mid/Low)
Motor
(m3/h)
(W)
570/510/450
780/700/600
53
39
Air filter
53
Remote controller
Gas side
(mm)
Liquid side
(mm)
O
/ 9.5
Sound pressure level (Note 2)
(dB(A))
(High/Mid/Low)
O
/ 12.7
O
/ 6.4
O
/ 15.9
O
/ 9.5
25 (Polyvinyl chloride tube)
Drain port (Nominal dia. mm)
PMV Kit
1260/
1140/
960
Standard filter (Long life filter)
Controller
Connecting
pipe
1140/960/720
34/32/30
35/33/30
38/35/33
40/37/34
Not available
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the
actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB
Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB/6oC WB
9-3 -1
60Hz
Specifications (60Hz)
Model name
MMU-
Cooling/Heating capacity (Note 1) (kW)
AP0091WH
AP0121WH
AP0151WH
AP0181WH
AP0241WH
AP0271WH
AP0301WH
2.2/2.5
2.8/3.2
3.6/4.0
4.5/5.0
5.6/6.3
7.1/8.0
8.0/9.0
9.0/10.0
1 phase 60Hz 220V (Separate power supply for indoor units is required.)
Power supply
Running current
Electrical
characteristics
AP0071WH
(A)
0.33
0.38
0.53
0.58
Power
consumption
(kW)
0.070
0.076
0.115
0.123
Power factor
(%)
97
90
99
96
Starting current
(A)
0.46
0.59
0.87
0.96
Heat-insulating material attached Zinc hot dipping steel plate
Main unit
Appearance
Ceiling
panel
Main
unit
Outer
dimension
Ceiling
panel
Model
RBC-UW136PG
RBC-UW266PG
Panel color
Light ivory (Munsell 10Y 9/0.5)
Height
(mm)
Width
(mm)
Depth
(mm)
550
Height
(mm)
8
Width
(mm)
Depth
(mm)
398
1.350
830
1,520
1,000
650
Main unit
(kg)
33
Ceiling panel
(kg)
8
44
48
Total weight
11
Heat exchanger
Finned tube
Soundproof/Heat-insulating material
Non-flammable insulation
Centrifugal fan
Fan
Fan unit Standard air flow
(High/Mid./Low)
Motor
(m3/h)
(W)
570/510/450
780/700/600
1,140/960/720
53
39
53
Air filter
1,260/1,140/960
Standard filter (Long life filter)
Controller
Remote controller
(mm)
Gas side
Connecting Liquid side
pipe
Drain port
O
/ 12.7
O
/ 9.5
(mm)
O
/ 9.5
O
/ 6.4
(Nominal dia.mm)
Sound pressure level(Note 2)
(High/Mid./Low)
(dB(A))
O
/ 15.9
25 (Polyvinyl chloride tube)
35/33/30
34/32/30
PMV Kit
38/35/33
40/37/34
Not available
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in
the actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions
Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
O
O
O
9-3 -2
O
O
O
9-3-2. Dimension
MMU-AP0071WH, AP0091WH, AP0121WH
Z view
Center of panel
Center of main unit
Air discharge port
(2-way)
1000
Electric parts box
95
650
Hanging bolt
pitch 480
Unit external
dimension 550
Ceiling open
dimension 620
Panel external
dimension 650
35
Air suction port
(2-way)
30
Unit external dimension
830
Hanging bolt pitch
880
Ceiling open dimension
960
Panel external dimension
1000
Hanging bolt
4-M10 procured locally
265
Ceiling panel
(Procured locally)
Z
Bottom face of ceiling
Branch duct knockout hole
(also on opposite side)
508mm or less
100mm
or less
160mm or less
Space required for installation and servicing
222
1000
or more
1000
or more
Indoor unit
Bottom face of ceiling
Refrigerant pipe
connecting port
(Gas side O
/ 9.5)
100
Refrigerant pipe
connecting port
(Liquid side O
/ 6.4)
75 55
Pour water port
¯ 150
Wired remote controller
RBC-AMT31E
Simple wired remote controller
RBC-AS21E2
Drain pipe connecting port
Inner O
/ 32, Nominal O/ 25
for vinyl chloride pipe
56
78
35
210
Power supply
connecting port
35
178
242
282
348
Obstruction
60
156
1000 or more
0
¯ 20
8
398
Ceiling
53
5mm
or more
Knockout hole for taking-in air
(Only at reverse side)
Wireless remote controller kit
TCB-AX21E2
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
Note: All dimensions are in mm.
9-3 -3
MMU-AP0151WH, AP0181WH, AP0241WH, AP0271WH. AP0301WH
Z view
Center of main unit
Center of panel
Air discharge port
(2-way)
Electric parts box
Air suction port
(2-way)
650
Hanging bolt
pitch 480
Unit external
dimension 550
Ceiling open
dimension 620
Panel external
dimension 650
95
35
30
Unit external dimension 1350
Hanging bolt pitch 1400
Ceiling open dimension 1480
Panel external dimension 1520
Space required for installation and servicing
53
156
398
1000
or more
1000
or more
60
8
Obstruction
0
¯ 20
222
5mm
or more
1000 or more
Ceiling
Hanging bolt
4-M10 procured locally
295
Ceiling panel
(Procured locally)
Bottom face of ceiling
Z
508mm or less
Drain pipe connecting port
Inner O
/ 32, Nominal O/ 25
for vinyl chloride pipe
75
55
Pour water port
Refrigerant pipe
connecting port
(Gas side O
/ B)
56
Refrigerant pipe
connecting port
100
(Liquid side O A)
Bottom face of ceiling
/
35
35
78
Wired remote controller
RBC-AMT31E
¯ 150
210
Power supply
connecting port
Simple wired remote controller
RBC-AS21E2
Knockout hole for air intake
(Only at reverse side)
Model
MMU-AP0151WH to AP0181WH
MMU-AP0241WH to AP0301WH
Wireless remote controller kit
TCB-AX21E2
178
242
282
348
100mm
or less
160mm or less
Branch duct knockout hole
(Also on opposite side)
A
B
O
/ 6.4
O
/ 12.7
O
/ 9.5
O
/ 15.9
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
Note: All dimensions are in mm.
9-3 -4
MMU-AP0481WH*CHINA market only
Z view
Center of panel
Center of main unit
Air suction port
(2-way)
680
Ceiling open
dimension 650
Panel external
dimension 680
Hanging bolt
pitch 510
Unit external
dimension 620
5
95
Air discharge port
(2-way)
1898
Electric parts box
105
Unit external dimension 1650
Hanging bolt pitch 1700
Ceiling open dimension 1850
Panel external dimension 1898
1000
or more
Space required for installation and servicing
68
¯2
00
¯2
00
406
1000
Obstruction or more
60
8
Ceiling
230
166
5mm
or more
1000 or more
Hanging bolt
4-M10 procured locally
150
455
Ceiling panel
(Procured locally)
Z
Bottom face of ceiling
Refrigerant pipe
connecting port
(Gas side O
/ 15.9)
Refrigerant pipe
56
connecting port
100
(Liquid side O
9.5)
/
15
86
Bottom face of ceiling
Drain pipe connecting port
(VP25)
75
55
Pour water port
50
¯1
15
186
250
290
356
516mm or less
100mm
or less
160mm or less
Branch duct knockout hole
(Also on reverse side)
210
Power supply
Knockout hole for air intake
connecting port
(Only at reverse side)
2.7
• Wired remote controller (RBC-AMT21E)
4
Wired remote controller
RBC-AMT31E
120
Simple wired remote controller
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E2
120
16
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
Note: All dimensions are in mm.
9-3 -5
Power supply
Single phase
220-240V 50Hz
220V 60Hz
Closed end
connector
Flow selector
unit earth
screw
Indoor unit
Earth screw R(L) S(N)
RED : RED
WHI : WHITE
YEL :YELLOW
BLU : BLUE
BLK : BLACK
GRY : GRAY
PNK : PINK
ORN :ORANGE
BRN : BROWN
GRN : GREEN
Color
indication
1
(BLK)
CN044 1
(BRW) 2
Outdoor unit
U1 U2
1 2
1 2
CN1
(WHI)
Remote controller
U1 U2
BLK
RC
YEL
BLU
ORN
L
1 2 3 4 5
RY005
RY006
M
CN050
(WHI)
H
CN02
(BLU)
3 3
2
1 1
MCC-1401
LM
FS
TR
1 2 3 4 5 6 CN01
1 2 3 4 5 6 (WHI)
Sub P.C. board
MCC-1520
1 2 3 4 5 6 CN02
1 2 3 4 5 6 (YEL)
CN075
(WHI)
1 2 3 4 5 6
CN061
(YEL)
3.
indicates the control P.C. board.
PMV
PMV
CN060
(WHI)
Symbol
FM
RC
LM
TR
TA
TC1,TC2,TCJ
RY001
RY002
RY004
RY005~007
FS
DM
PMV
1
2
3
4
5
1 1
2 2
TA
Filter
TC1
TC2
TCJ
1 EXCT
2
Parts name
Fan motor
Running capacitor
Transformer
Louver motor
Indoor temp sensor
Temp sensor
Louver control relay
Drain control relay
Heater control relay
Fan motor control relay
Float switch
Drain pump motor
Pulse Motor Valve
Option
1 2 3 4 5 6
Fan drive
1 2
CN032
(WHI)
CN081
(BLK)
CN070
(WHI)
CN073
(RED)
CN080
(GRN)
1
2 PNL
3
1 1
2 2
3 3
1 1
2 2
CN101
(BLK)
CN100
(BRW)
1 1
2 2
1 1
2 2
CN102
(RED)
CN104
(YEL)
1 2 3 4 5 6 (BLU)
1 2 3 4 5 6 CN082
6 4 3 1 2 5
6 4 3 1 2 5
Indoor control P.C. board
1 2 3 4 5 6
1 2 3 4 5 6
Power supply
circuit
RY001
indicates the terminal block, the letter inside
indicates the terminal number.
1 2 3
1 2 3
CN074
(WHI)
RY002
UL
DP
FS
1 2 3 (BLU) 1 2 3 (GRN) 1 2 3 (RED)
1 2 3 CN068 1 2 3 CN033 1 2 3 CN030
DM
1 2
1 2
LM
2 . A dotted line and broken line indicate the wiring on site.
1.
CN03
(RED)
1 1
2 2
Network
CN01 1 2 adaptor
(WHI) 1 2 (Option)
RY007
RED
FAN
9 8 7 6 5 4 3 2 1
CN083(WHI) 9 8 7 6 5 4 3 2 1
A B X Y
1 2 3
1 2 3
CN040 CN041
(BLU) (BLU)
1 2
1 2
Line Filter
TR
Fuse
T5.0A
RY004
P301
1 1
2 2 CN067 250V~
(BLK)
3 3
1 1
2 2
3 3
CN066 1
(WHI) 2
CN039
(YEL)
3
CN304
(GRY) 2
9
BLK
FM
WHI
1
2
RED
3
4
5
6
7
BLU
BLU
9-3 -6
BLK
1
2
3
4
5
6
7
9-3-3. Wiring diagram
Model:MMU-AP0071WH, AP0091WH, AP0121WH, AP0151WH, AP0181WH,
MMU-AP0241WH, AP0271WH, AP0301WH, AP0481WH
9-3-4. Sensible capacity table
(MMU-AP***WH)
Cooling capacity
Unit
size
007
009
012
015
Outdoor
air temp.
°CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
16.0°CWB
23°CDB
TC
SHC
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
1.9
1.6
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
1.9
2.4
1.9
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.2
2.3
3.1
2.2
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.0
3.0
3.9
2.8
18.0°CWB
26°CDB
TC
SHC
2.1
1.8
2.1
1.8
2.1
1.8
2.1
1.8
2.1
1.8
2.1
1.8
2.1
1.8
2.1
1.8
2.1
1.8
2.1
1.8
2.1
1.8
2.1
1.8
2.1
1.8
2.1
1.8
2.1
1.8
2.0
1.7
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.6
2.0
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.4
2.5
3.4
2.4
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.3
3.1
4.2
3.0
TC : Total Capacity (kW) SHC : Sensible Heat Capacity (kW)
Indoor air temp.
19.0°CWB
20.0°CWB
22.0°CWB
24.0°CWB
27°CDB
28°CDB
30°CDB
32°CDB
TC
SHC
TC
SHC
TC
SHC
TC
SHC
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.2
1.8
2.4
1.7
2.5
1.7
2.1
1.7
2.2
1.7
2.3
1.7
2.4
1.6
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.7
2.1
2.8
2.1
3.0
2.0
3.1
2.0
2.7
2.0
2.8
2.0
2.9
2.0
3.1
1.9
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.5
2.5
3.6
2.4
3.8
2.4
4.0
2.4
3.5
2.4
3.6
2.4
3.8
2.3
3.9
2.3
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.4
3.1
4.5
3.1
4.8
3.1
5.0
3.0
4.3
3.0
4.4
3.0
4.7
3.0
4.9
2.9
9-3 -7
Cooling capacity (cont.)
Unit
size
018
024
027
Outdoor
air temp.
°CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
16.0°CWB
23°CDB
TC
SHC
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.0
3.6
4.9
3.5
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.3
4.6
6.2
4.4
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.3
4.6
6.2
4.4
18.0°CWB
26°CDB
TC
SHC
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.3
3.8
5.2
3.7
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.7
4.9
6.6
4.7
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.7
4.9
6.6
4.7
Indoor air temp.
19.0°CWB
27°CDB
TC
SHC
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.5
3.8
5.4
3.7
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.0
4.9
6.8
4.7
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.0
4.9
6.8
4.7
9-3 -8
20.0°CWB
28°CDB
TC
SHC
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.7
3.8
5.5
3.7
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.2
4.9
7.0
4.7
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.2
4.9
7.0
4.7
22.0°CWB
30°CDB
TC
SHC
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.0
3.8
5.9
3.6
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.6
4.9
7.4
4.7
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.6
4.9
7.4
4.7
24.0°CWB
32°CDB
TC
SHC
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.3
3.7
6.1
3.6
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
7.9
4.7
7.8
4.6
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
7.9
4.7
7.8
4.6
Heating capacity
Unit
size
007
009
012
015
Outdoor
air temp.
°CWB
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
SHC
1.6
1.7
1.8
1.8
1.9
2.0
2.1
2.2
2.3
2.4
2.5
2.6
2.6
2.6
2.6
2.6
2.0
2.1
2.3
2.3
2.5
2.6
2.7
2.9
3.0
3.1
3.2
3.3
3.3
3.3
3.3
3.3
2.5
2.7
2.8
2.9
3.1
3.3
3.4
3.6
3.7
3.9
4.0
4.2
4.2
4.2
4.2
4.2
3.1
3.3
3.6
3.7
3.9
4.1
4.3
4.5
4.7
4.8
5.0
5.2
5.2
5.2
5.2
5.2
SHC : Sensible Heat Capacity (kW)
Indoor air temp. °CDB
18.0
20.0
22.0
24.0
SHC
SHC
SHC
SHC
1.5
1.5
1.5
1.4
1.6
1.6
1.6
1.5
1.7
1.7
1.7
1.6
1.8
1.8
1.7
1.7
1.9
1.9
1.8
1.8
2.0
2.0
1.9
1.9
2.1
2.0
2.0
1.9
2.2
2.1
2.1
2.0
2.3
2.2
2.2
2.1
2.4
2.3
2.3
2.2
2.5
2.4
2.4
2.3
2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.0
1.9
1.9
1.8
2.1
2.1
2.0
1.9
2.2
2.2
2.1
2.1
2.3
2.2
2.2
2.1
2.4
2.4
2.3
2.3
2.6
2.5
2.4
2.4
2.7
2.6
2.6
2.5
2.8
2.7
2.7
2.6
2.9
2.9
2.8
2.7
3.0
3.0
2.9
2.8
3.2
3.1
3.0
2.9
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
2.5
2.4
2.3
2.3
2.6
2.6
2.5
2.4
2.8
2.7
2.7
2.6
2.9
2.8
2.7
2.7
3.0
3.0
2.9
2.8
3.2
3.1
3.0
3.0
3.3
3.3
3.2
3.1
3.5
3.4
3.3
3.3
3.7
3.6
3.5
3.4
3.8
3.7
3.6
3.5
3.9
3.9
3.8
3.7
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
3.1
3.0
2.9
2.9
3.3
3.2
3.1
3.0
3.5
3.4
3.3
3.2
3.6
3.5
3.4
3.3
3.8
3.7
3.6
3.5
4.0
3.9
3.8
3.7
4.2
4.1
4.0
3.9
4.4
4.3
4.2
4.1
4.6
4.5
4.4
4.2
4.7
4.6
4.5
4.4
4.9
4.8
4.7
4.6
5.1
5.0
4.9
4.8
5.1
5.0
4.9
4.8
5.1
5.0
4.9
4.8
5.1
5.0
4.9
4.8
5.1
5.0
4.9
4.8
9-3 -9
Heating capacity (cont.)
Unit
size
018
024
027
Outdoor
air temp.
°CWB
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
SHC
3.9
4.2
4.5
4.6
4.9
5.1
5.4
5.6
5.9
6.1
6.3
6.6
6.6
6.6
6.6
6.6
5.0
5.3
5.7
5.8
6.2
6.5
6.8
7.1
7.4
7.7
8.0
8.3
8.3
8.3
8.3
8.3
5.6
6.0
6.4
6.6
7.0
7.3
7.7
8.0
8.4
8.7
9.0
9.4
9.4
9.4
9.4
9.4
Indoor air temp. °CDB
18.0
20.0
22.0
SHC
SHC
SHC
3.9
3.8
3.7
4.1
4.0
3.9
4.4
4.3
4.2
4.5
4.4
4.3
4.8
4.7
4.6
5.0
4.9
4.8
5.3
5.2
5.0
5.5
5.4
5.3
5.8
5.6
5.5
6.0
5.9
5.7
6.2
6.1
5.9
6.4
6.3
6.1
6.4
6.3
6.1
6.4
6.3
6.1
6.4
6.3
6.1
6.4
6.3
6.1
4.9
4.8
4.7
5.2
5.1
5.0
5.6
5.5
5.3
5.7
5.6
5.5
6.1
5.9
5.8
6.4
6.2
6.1
6.7
6.6
6.4
7.0
6.9
6.7
7.3
7.1
7.0
7.6
7.4
7.3
7.9
7.7
7.5
8.2
8.0
7.8
8.2
8.0
7.8
8.2
8.0
7.8
8.2
8.0
7.8
8.2
8.0
7.8
5.5
5.4
5.3
5.9
5.8
5.6
6.3
6.1
6.0
6.5
6.3
6.2
6.8
6.7
6.5
7.2
7.0
6.9
7.5
7.4
7.2
7.9
7.7
7.5
8.2
8.0
7.8
8.5
8.4
8.2
8.9
8.7
8.5
9.2
9.0
8.8
9.2
9.0
8.8
9.2
9.0
8.8
9.2
9.0
8.8
9.2
9.0
8.8
24.0
SHC
3.6
3.8
4.1
4.2
4.4
4.7
4.9
5.1
5.3
5.6
5.8
6.0
6.0
6.0
6.0
6.0
4.6
4.9
5.2
5.3
5.6
5.9
6.2
6.5
6.8
7.1
7.3
7.6
7.6
7.6
7.6
7.6
5.1
5.5
5.8
6.0
6.3
6.7
7.0
7.3
7.6
7.9
8.3
8.6
8.6
8.6
8.6
8.6
9-3 -10
9-3-5. Air throw distance chart
MMUAP0071WH, AP0091WH, AP0121WH
MMUAP0151WH, AP0181WH
2.7m
Ceiling height (m)
Ceiling height (m)
2.7m
2
1.0
0.5
(m) 1
0.3
0.3
0
1
2
2
1.0
(m) 1
0.5
0.3
0.3
0
3m
Horizontal distance (m)
1
2
3m
Horizontal distance (m)
MMU-AP0241WH, AP0271WH
Ceiling height (m)
2.7m
2
1.0
(m) 1
0.5
0.3
0.3
0
1
2
3m
Horizontal distance (m)
MMU-AP0481WH
MMU-AP0301WH
2.7
Ceiling height (m)
Ceiling height (m)
2.7
2
1.0
1
0.5
0.3
0
2
1.0
1
0.3
1
2
3
0.5
0.3
0.3
4
0
1
2
3
Horizontal distance (m)
Horizontal distance (m)
9-3 -11
4
9-3-6. Sound characteristics (NC-Curve)
Sound level values shown are based on a measurement in a non resound room.
MMU-AP0071WH, AP0091WH, AP0121WH
Fan Tap
H
M
L
Sound pressure
level (dB(A))
34
32
30
Microphone
Octave band sound pressure level (dB)
standard sound pressure 0.0002 µbar
Audibility limits
of continuous
white level
Octave band frequency (Hz)
MMU-AP0241WH, AP0271WH
MMU-AP0151WH, AP0181WH
Fan Tap
Sound pressure
level (dB(A))
H
35
M
33
L
30
Audibility limits
of continuous
white level
H
M
L
38
35
33
standard sound pressure 0.0002 µbar
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
standard sound pressure 0.0002 µbar
Fan Tap
Sound pressure
level (dB(A))
Octave band frequency (Hz)
Audibility limits
of continuous
white level
Octave band frequency (Hz)
9-3 -12
Octave band sound pressure level (dB)
MMU-AP0301WH
Fan T
ap
Tap
H
M
L
Sound pressure
level (dB(A))
40
37
34
90
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
H
M
20
Audibility limits
of continuous white level
NC-20
L
10
63
125
250
500
1000
2000
4000
8000
Octave band center frequency (Hz)
9-3 -13
(Revised edition in 7.Apr.2006)
9-3-7. Accessories
Apperarance
Standard accessories
Qty
Shape
Installation Manual
1
—
Heat insulating pipe
2
Installation
pattern
Part name
MMU-AP0301WH
type or lower
1
MMU-AP0481WH
type
2
—
Use
Part name
Qty
(Be sure to hand
over to customer)
Installation
gauge
1
For heat insulating
pipe connecting
section
Pattern
fixing screw
6
Fan motor
For checking the
connector
position of the ceiling
openings and the
Heat
unit
insulator
Shape
Use
For positioning of ceiling position
(United with installation pattern)
For attaching the installation
pattern
M 5 x 16
1
For changing fan motor
r.p.m. to apply higher ceiling
1
For seal for wire connecting
port
Ceiling panel components
Name
Ceiling panel
Center panel
Air filter
Shape
(Qty)
(1 set)
Usage
—
(1 pc)
—
• RBC-UW466PG :
Attached to indoor unit
Attached to ceiling
panel, and removes
dust.
Remote controller
Model Name
Wired remote controller
RBC-AMT31E
Simple wired remote controller
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E2
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
Central remote controller
TCB-SC642TLE2
ON-OFF controller
TCB-CC163TLE2
9-3 -14
Screw installing panel
Screw installing panel
20mm
30mm
M5×20
M5×30
(4 pcs)
For fixing ceiling
panel
(4 corners)
(2 pcs)
For tentative hanging
and fixing ceiling
panel (Center part)
Optional accessories
Ceiling panel
RBC-UW136PG
RBC-UW266PG
RBC-UW466PG
Name
Ceiling panel
Model name
RBC-UW136PG
RBC-UW266PG
Note
Required accessory
9-3 -15
9-4-1. Specifications
50Hz
Specifications (50Hz)
Model name
MMU-
AP0071YH
AP0091YH
AP0121YH
AP0152SH
AP0182SH
AP0242SH
(kW)
2.2/2.5
2.8/3.2
3.6/4.0
4.5/5.0
5.6/6.3
7.1/8.0
Cooling/Heating capacity (Note 1)
Power supply
Electrical
characteristics
(Note 2)
1 phase 50Hz 230V (220-240V) (Separate power supply for indoor units is required.)
Running current
(A)
0.24
0.34
0.37
0.62
Power consumption
(kW)
0.053
0.042
0.046
0.075
Power factor
(%)
95
_
_
_
Starting current
(A)
0.6
0.53
0.54
0.80
Main unit
Appearance
Ceiling
panel
Heat-insulating material attached Zinc hot dipping steel plate
Model
Panel color
RBC-UY135PG
RBC-US21PGE
W : Silky shade (1Y8.5/0.5)
Moon white (Munsel 2.5GY9.0/0.5)
Height
(mm)
235
200
Width
(mm)
850
1,000
Depth
(mm)
400
710
Height
(mm)
18
20
Width
(mm)
1,050
1,230
Depth
(mm)
470
800
Main unit
(kg)
22
Ceiling panel
(kg)
3.5
Main unit
Outer
dimension
Ceiling
panel
21
22
Total weigh
5.5
Heat exchanger
Finned tube
Soundproof/Heat-insulating material
Non-flammable insulation
Centrifugal fan
Fan
Fan unit
Standard air flow
(High/Mid/Low)
Motor
(m3/h)
(W)
540/480/420
750/690/630
780/720/660 1,140/960/810
22
30
Remote controller
Controller
Standard filter (Long life filter)
Air filter
Connecting
pipe
Polyethylene foam + Expanded polystyrene
Gas side
(mm)
Liquid side
(mm)
Drain port (Nominal dia. mm)
Sound pressure level (Note 2)
(High/Mid/Low)
(dB(A))
O
/ 9.5
O
/ 12.7
O
/ 15.9
O
/ 6.4
O
/ 9.5
25 (Polyvinyl chloride tube:External dia.32 Internal dia.25)
42/39/34
PMV Kit
37/35/32
38/36/34
45/41/37
Available
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the
actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB
Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB/6oC WB
9-4 -1
60Hz
Specifications (60Hz)
Model name
MMU-
AP0071YH
AP0091YH
AP0121YH
AP0152SH
AP0182SH
AP0242SH
(kW)
2.2/2.5
2.8/3.2
3.6/4.0
4.5/5.0
5.6/6.3
7.1/8.0
Cooling/Heating capacity (Note 1)
Power supply
Electrical
characteristics
(Note 2)
1 phase 60Hz 220V (Separate power supply for indoor units is required.)
Running current
(A)
0.26
0.35
0.39
0.62
Power consumption
(kW)
0.056
0.041
0.045
0.073
Power factor
(%)
98
_
_
_
Starting current
(A)
0.60
0.53
0.54
0.80
Main unit
Appearance
Ceiling
panel
Heat-insulating material attached Zinc hot dipping steel plate
Model
Panel color
RBC-UY135PG
RBC-US21PGE
W : Silky shade (1Y8.5/0.5)
Moon white (Munsel 2.5GY9.0/0.5)
Height
(mm)
235
200
Width
(mm)
850
1,000
Depth
(mm)
400
710
Height
(mm)
18
20
Width
(mm)
1,050
1,230
Depth
(mm)
470
800
Main unit
(kg)
22
Ceiling panel
(kg)
3.5
Main unit
Outer
dimension
Ceiling
panel
21
22
Total weigh
5.5
Heat exchanger
Finned tube
Soundproof/Heat-insulating material
Non-flammable insulation
Centrifugal fan
Fan
Fan unit
Standard air flow
(High/Mid/Low)
Motor
(m3/h)
(W)
540/480/420
750/690/630
780/720/660 1,140/960/810
22
30
Remote controller
Controller
Standard filter (Long life filter)
Air filter
Connecting
pipe
Polyethylene foam + Expanded polystyrene
Gas side
(mm)
Liquid side
(mm)
Drain port (Nominal dia. mm)
Sound pressure level (Note 2)
(High/Mid/Low)
(dB(A))
O
/ 9.5
O
/ 12.7
O
/ 15.9
O
/ 6.4
O
/ 9.5
25 (Polyvinyl chloride tube:External dia.32 Internal dia.25)
42/39/34
PMV Kit
37/35/32
38/36/34
45/41/37
Available
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the
actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB
Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB/6oC WB
9-4 -2
9-4-2. Dimension
MMU-AP0071YH, AP0091YH, AP0121YH
Panel external dimension 1050
Drain pipe connecting port
(VP25)
20
Power supply
connecting port
Panel external
dimension 470
Ceiling open
dimension 430
20
Ceiling open dimension 1010
Center of panel
Hanging bolt
4-M10 procured locally
Support
metal
Refrigerant pipe connecting port
(Gas side) Ø9.5
Discharge louver
Refrigerant pipe connecting port
(Liquid side) Ø6.4
Ceiling panel
Procured locally
Air discharge port
Bottom face of ceiling
Panel mounting hole
5 positions
Air suction port
4
2.7
Dimensions
Model MMU-
A
B
C
AP0071YH,AP0091YH, AP0121YH
235
245
200
B
or more
Wired remote controller
RBC-AMT31E
120
Simple wired remote controller
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E2
Weekly timer application
120
16
RBC-AMT31E and RBC-EXW21E2
100 or more
100 or more
200 or more
Space required for installation and servicing
Note: All dimensions are in mm.
9-4 -3
MMU-AP0152SH, AP0182SH, AP0242SH
56
Cable inlet (Knockout hole)
252
248
Drain pipe connecting port
(Be sure to connect the attached flexible hose.)
112
72
Fresh air inlet (Ø92 knockout hole)
20
C/L
216
800 Panel external size
760 Ceiling opening size
220
475 Hanging bolt pitch
1060 Hanging bolt pitch
20
1190 Ceiling opening size
1230 Panel external size
20
20
135
710 Unit external size
233
122
C/L
80 60
43
Cable inlet
100
Ø112 (4-tapping screw under-hole)
94
154
Refrigerant pipe connecting port
Gas side B
Refrigerant pipe connecting port
Liquid side A
1000 Unit external size
706
20
73.4
93
200
76
Hanging bolt M10 or W3/8 (Local supply)
Lower surface of ceiling
Ceiling panel (Sold separately)
For front air discharge unit (Sold separately) knockout hole
4
2.7
Model name
Wired remote controller
RBC-AMT31E
120
Simple wired remote controller
RBC-AS21E2
Wireless remote controller kit
120
TCB-AX21E2
16
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
9-4 -4
MMU-
A
B
AP015, AP018 type
O
/ 6.4
O
/ 12.7
AP024 type
O
/ 9.5
O
/ 15.9
RED : RED
WHI : WHITE
YEL :YELLOW
BLU : BLUE
BLK : BLACK
GRY : GRAY
PNK : PINK
ORN :ORANGE
BRN : BROWN
GRN : GREEN
Color
indication
RED
WHI
Power supply
Single phase
220-240V 50Hz
220V 60Hz
Indoor unit
Earth screw R(L) S(N)
RED
WHI
1 1
3
CN304
(GRY) 2
1
Heater
CN301
(BLK)
BLU
RY004
Line Filter
TR
BLU
1 2
1 2
Outdoor
unit
U1 U2
1 2
1 2
CN1
(WHI)
AI-NET
central control
terminal
A B X Y
1 2 3
1
3
Remote controller
U1 U2
BLU
1 2
1 2
YEL
BLU
ORN
BLK
RED
L
CN03
(RED)
1 1
2 2
LM
2 1
2 1
FS
FS
CN075
(WHI)
TR
1 2 3 4 5 6 CN01
1 2 3 4 5 6 (WHI)
Sub P.C. board
MCC-1520
1 2 3 4 5 6
CN061
(YEL)
3.
indicates the control P.C. board.
PMV
PMV
CN060
(WHI)
Symbol
FM
RC
TR
LM
TA
TC1,TCJ
RY001
RY002
RY004
RY005~007
FS
DM
PMV
Parts name
Fan motor
Running capacitor
Power transformer
Louver motor
Indoor temp sensor
Temp sensor
Flap motor control relay
Drain pump control relay
Heater control relay
Fan motor control relay
Float switch
Drain pump motor
Pulse Motor Valve
Option
1
2
3
4
5
1 1
Filter
2 2
CN070
(WHI)
CN081
(BLK)
1 EXCT
2
1
2 PNL
3
TC1
TCJ
TA
CN073
(RED)
CN080
(GRN)
1 2 3 4 5 6
Fan drive
1 2
CN032
(WHI)
1
2
CN101
(BLK)
1 1
2 2
3 3
1 1
2 2
CN102
(RED)
CN100
(BRW)
1 1
2 2
CN104
(YEL)
1 2 3 4 5 6 (BLU)
1 2 3 4 5 6 CN082
6 4 3 1 2 5
6 4 3 1 2 5
Indoor control P.C. board
1 2 3 4 5 6 CN02
1 2 3 4 5 6 (YEL)
1 2 3 4 5 6
1 2 3 4 5 6
Power supply
circuit
RY001
indicates the terminal block, the letter inside
indicates the terminal number.
1 2 3
1 2 3
CN074
(WHI)
RY002
UL
DP
2 1
2 1
LM
1 2 3 (BLU) 1 2 3 (GRN) 1 2 3 (RED)
1 2 3 CN068 1 2 3 CN033 1 2 3 CN030
1 2 3
1 2 3
DM
2 . A dotted line and broken line indicate the wiring on site.
1.
3 2 1 CN02
3 2 1 (BLU)
Network
adaptor
P.C. board
Network
CN01 1 2 adaptor
(WHI) 1 2 (Option)
1 2 3 4 5
RY005
RY006
M
CN050
(WHI)
H
MCC-1401
RY007
FAN
9 8 7 6 5 4 3 2 1
CN083(WHI) 9 8 7 6 5 4 3 2 1
CN044 CN040 CN041
(BRW) (BLU) (BLU)
1 1
2 2 CN067 Fuse
(BLK) T5.0A
3 3
CN066 1
(WHI) 2
AC IN
3 3
CN309
(YEL) 2 2
Closed end
connector
Flow selector
unit earth
screw
RC
BLU
FM
BLK
1
2
3
4
5
6
BLU
9-4 -5
BLK
1
2
3
4
5
6
9-4-3. Wiring diagram
1-way Air Discharge Cassette Type (Compact type)
Model: MMU-AP0071YH, AP0091YH, AP0121YH
on side
1-way (2 series) Air Discharge Cassette Type (MMU-AP***SH)
9-4 -6
9-4-4. Sensible capacity table
(MMU-AP***YH, MMU-AP***SH)
Cooling capacity
Unit
size
007
009
012
Outdoor
air temp.
°CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
16.0°CWB
23°CDB
TC
SHC
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
1.9
1.6
2.5
2.1
2.5
2.1
2.5
2.1
2.5
2.1
2.5
2.1
2.5
2.1
2.5
2.1
2.5
2.1
2.5
2.1
2.5
2.1
2.5
2.1
2.5
2.1
2.5
2.1
2.5
2.1
2.5
2.0
2.4
2.0
3.3
2.5
3.3
2.5
3.3
2.5
3.3
2.5
3.3
2.5
3.3
2.5
3.3
2.5
3.3
2.5
3.3
2.5
3.3
2.5
3.3
2.5
3.3
2.5
3.3
2.5
3.3
2.5
3.2
2.5
3.1
2.4
18.0°CWB
26°CDB
TC
SHC
2.1
1.8
2.1
1.8
2.1
1.8
2.1
1.8
2.1
1.8
2.1
1.8
2.1
1.8
2.1
1.8
2.1
1.8
2.1
1.8
2.1
1.8
2.1
1.8
2.1
1.8
2.1
1.8
2.1
1.8
2.0
1.7
2.7
2.2
2.7
2.2
2.7
2.2
2.7
2.2
2.7
2.2
2.7
2.2
2.7
2.2
2.7
2.2
2.7
2.2
2.7
2.2
2.7
2.2
2.7
2.2
2.7
2.2
2.7
2.2
2.7
2.2
2.6
2.1
3.5
2.7
3.5
2.7
3.5
2.7
3.5
2.7
3.5
2.7
3.5
2.7
3.5
2.7
3.5
2.7
3.5
2.7
3.5
2.7
3.5
2.7
3.5
2.7
3.5
2.7
3.5
2.7
3.4
2.7
3.4
2.5
TC : Total Capacity (kW) SHC : Sensible Heat Capacity (kW)
Indoor air temp.
19.0°CWB
20.0°CWB
22.0°CWB
24.0°CWB
27°CDB
28°CDB
30°CDB
32°CDB
TC
SHC
TC
SHC
TC
SHC
TC
SHC
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.2
1.8
2.4
1.7
2.5
1.7
2.1
1.7
2.2
1.7
2.3
1.7
2.4
1.6
2.8
2.2
2.9
2.2
3.1
2.2
3.2
2.1
2.8
2.2
2.9
2.2
3.1
2.2
3.2
2.1
2.8
2.2
2.9
2.2
3.1
2.2
3.2
2.1
2.8
2.2
2.9
2.2
3.1
2.2
3.2
2.1
2.8
2.2
2.9
2.2
3.1
2.2
3.2
2.1
2.8
2.2
2.9
2.2
3.1
2.2
3.2
2.1
2.8
2.2
2.9
2.2
3.1
2.2
3.2
2.1
2.8
2.2
2.9
2.2
3.1
2.2
3.2
2.1
2.8
2.2
2.9
2.2
3.1
2.2
3.2
2.1
2.8
2.2
2.9
2.2
3.1
2.2
3.2
2.1
2.8
2.2
2.9
2.2
3.1
2.2
3.2
2.1
2.8
2.2
2.9
2.2
3.1
2.2
3.2
2.1
2.8
2.2
2.9
2.2
3.1
2.2
3.2
2.1
2.8
2.2
2.9
2.2
3.1
2.2
3.2
2.1
2.7
2.2
2.8
2.2
3.0
2.1
3.1
2.1
2.7
2.1
2.8
2.1
2.9
2.1
3.1
2.0
3.6
2.7
3.7
2.7
3.9
2.7
4.1
2.6
3.6
2.7
3.7
2.7
3.9
2.7
4.1
2.6
3.6
2.7
3.7
2.7
3.9
2.7
4.1
2.6
3.6
2.7
3.7
2.7
3.9
2.7
4.1
2.6
3.6
2.7
3.7
2.7
3.9
2.7
4.1
2.6
3.6
2.7
3.7
2.7
3.9
2.7
4.1
2.6
3.6
2.7
3.7
2.7
3.9
2.7
4.1
2.6
3.6
2.7
3.7
2.7
3.9
2.7
4.1
2.6
3.6
2.7
3.7
2.7
3.9
2.7
4.1
2.6
3.6
2.7
3.7
2.7
3.9
2.7
4.1
2.6
3.6
2.7
3.7
2.7
3.9
2.7
4.1
2.6
3.6
2.7
3.7
2.7
3.9
2.7
4.1
2.6
3.6
2.7
3.7
2.7
3.9
2.7
4.1
2.6
3.6
2.7
3.7
2.7
3.9
2.7
4.1
2.6
3.5
2.6
3.6
2.6
3.8
2.6
4.0
2.6
3.5
2.5
3.6
2.5
3.8
2.5
3.9
2.5
9-4 -7
Cooling capacity (cont.)
Unit
size
015
018
024
Outdoor
air temp.
°CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
16.0°CWB
23°CDB
TC
SHC
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.0
3.0
3.9
2.8
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.0
3.6
4.9
3.5
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.3
4.6
6.2
4.4
18.0°CWB
26°CDB
TC
SHC
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.3
3.1
4.2
3.0
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.3
3.8
5.2
3.7
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.7
4.9
6.6
4.7
Indoor air temp.
19.0°CWB
27°CDB
TC
SHC
4.5
3.2
4.5
3.2
4.5
3.2
4.5
3.2
4.5
3.2
4.5
3.2
4.5
3.2
4.5
3.2
4.5
3.2
4.5
3.2
4.5
3.2
4.5
3.2
4.5
3.2
4.5
3.2
4.4
3.1
4.3
3.0
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.5
3.8
5.4
3.7
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.0
4.9
6.8
4.7
20.0°CWB
28°CDB
TC
SHC
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.5
3.1
4.4
3.0
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.7
3.8
5.5
3.7
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.2
4.9
7.0
4.7
9-4 -8
22.0°CWB
30°CDB
TC
SHC
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.8
3.1
4.7
3.0
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.0
3.8
5.9
3.6
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.6
4.9
7.4
4.7
24.0°CWB
32°CDB
TC
SHC
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.0
3.0
4.9
2.9
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.3
3.7
6.1
3.6
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
7.9
4.7
7.8
4.6
Heating capacity
Unit
size
007
009
012
Outdoor
air temp.
°CWB
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
SHC
1.6
1.7
1.8
1.8
1.9
2.0
2.1
2.2
2.3
2.4
2.5
2.6
2.6
2.6
2.6
2.6
2.0
2.1
2.3
2.3
2.5
2.6
2.7
2.9
3.0
3.1
3.2
3.3
3.3
3.3
3.3
3.3
2.5
2.7
2.8
2.9
3.1
3.3
3.4
3.6
3.7
3.9
4.0
4.2
4.2
4.2
4.2
4.2
SHC : Sensible Heat Capacity (kW)
Indoor air temp. °CDB
18.0
20.0
22.0
24.0
SHC
SHC
SHC
SHC
1.5
1.5
1.5
1.4
1.6
1.6
1.6
1.5
1.7
1.7
1.7
1.6
1.8
1.8
1.7
1.7
1.9
1.9
1.8
1.8
2.0
2.0
1.9
1.9
2.1
2.0
2.0
1.9
2.2
2.1
2.1
2.0
2.3
2.2
2.2
2.1
2.4
2.3
2.3
2.2
2.5
2.4
2.4
2.3
2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.0
1.9
1.9
1.8
2.1
2.1
2.0
1.9
2.2
2.2
2.1
2.1
2.3
2.2
2.2
2.1
2.4
2.4
2.3
2.3
2.6
2.5
2.4
2.4
2.7
2.6
2.6
2.5
2.8
2.7
2.7
2.6
2.9
2.9
2.8
2.7
3.0
3.0
2.9
2.8
3.2
3.1
3.0
2.9
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
2.5
2.4
2.3
2.3
2.6
2.6
2.5
2.4
2.8
2.7
2.7
2.6
2.9
2.8
2.7
2.7
3.0
3.0
2.9
2.8
3.2
3.1
3.0
3.0
3.3
3.3
3.2
3.1
3.5
3.4
3.3
3.3
3.7
3.6
3.5
3.4
3.8
3.7
3.6
3.5
3.9
3.9
3.8
3.7
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
9-4 -9
Heating capacity (cont.)
Unit
size
015
018
024
Outdoor
air temp.
°CWB
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
SHC
3.1
3.3
3.6
3.7
3.9
4.1
4.3
4.5
4.7
4.8
5.0
5.2
5.2
5.2
5.2
5.2
3.9
4.2
4.5
4.6
4.9
5.1
5.4
5.6
5.9
6.1
6.3
6.6
6.6
6.6
6.6
6.6
5.0
5.3
5.7
5.8
6.2
6.5
6.8
7.1
7.4
7.7
8.0
8.3
8.3
8.3
8.3
8.3
Indoor air temp. °CDB
18.0
20.0
22.0
SHC
SHC
SHC
3.1
3.0
2.9
3.3
3.2
3.1
3.5
3.4
3.3
3.6
3.5
3.4
3.8
3.7
3.6
4.0
3.9
3.8
4.2
4.1
4.0
4.4
4.3
4.2
4.6
4.5
4.4
4.7
4.6
4.5
4.9
4.8
4.7
5.1
5.0
4.9
5.1
5.0
4.9
5.1
5.0
4.9
5.1
5.0
4.9
5.1
5.0
4.9
3.9
3.8
3.7
4.1
4.0
3.9
4.4
4.3
4.2
4.5
4.4
4.3
4.8
4.7
4.6
5.0
4.9
4.8
5.3
5.2
5.0
5.5
5.4
5.3
5.8
5.6
5.5
6.0
5.9
5.7
6.2
6.1
5.9
6.4
6.3
6.1
6.4
6.3
6.1
6.4
6.3
6.1
6.4
6.3
6.1
6.4
6.3
6.1
4.9
4.8
4.7
5.2
5.1
5.0
5.6
5.5
5.3
5.7
5.6
5.5
6.1
5.9
5.8
6.4
6.2
6.1
6.7
6.6
6.4
7.0
6.9
6.7
7.3
7.1
7.0
7.6
7.4
7.3
7.9
7.7
7.5
8.2
8.0
7.8
8.2
8.0
7.8
8.2
8.0
7.8
8.2
8.0
7.8
8.2
8.0
7.8
24.0
SHC
2.9
3.0
3.2
3.3
3.5
3.7
3.9
4.1
4.2
4.4
4.6
4.8
4.8
4.8
4.8
4.8
3.6
3.8
4.1
4.2
4.4
4.7
4.9
5.1
5.3
5.6
5.8
6.0
6.0
6.0
6.0
6.0
4.6
4.9
5.2
5.3
5.6
5.9
6.2
6.5
6.8
7.1
7.3
7.6
7.6
7.6
7.6
7.6
9-4 -10
9-4-5. Air throw distance chart
1-way Air Discharge Cassette T
ype (Compact type)
Type
MMU-AP0071YH, AP0091YH, AP0121YH
H (High wind,
blowing downward)
2.7m
5.0
L (Low wind,
blowing downward)
4.0
2.7m
2
2
H (High wind,
blowing horizontally)
2.7m 4.5
1.7
2
2.5
L (Low wind,
blowing horizontally)
2.7m 3.0
0.3
2
1.5
0.4
1.5
1.1
0.3
2.3
1
1
1
0.9
0.4
0
1
0.5
0.6
1
0.4
2
0.2
0
3m
0.3
1
0.2
2
3m
0
1
2
3m
0
1
2
3m
1-way (2 series) Air Discharge Cassette T
ype
Type
Heating mode
MMU-AP0242SH
MMU-AP0152SH, AP0182SH
3.5m
Main unit
3.5m
Main unit
3m
3m
2m
2m
0.3
1.0
1m
0.3
1.0
0.3
1m
0.5
0.3
0.5
0.5
0.5
1m
2m
3m
4m
1m
9-4 -11
2m
3m
4m
(Revised edition in 7.Apr.2006)
9-4-6. Sound characteristics (NC-Curve)
1-way Air Discharge Cassette T
ype (Compact type)
Type
MMU-AP0071YH, AP0091YH,
AP0121YH
Fan tap
Sound pressure
level (dB(A))
H
M
L
42
39
34
Microphone
9-4 -12
(Revised edition in 7.Apr.2006)
1-way (2 series) Air Discharge Cassette Type
MMU-AP0242SH
MMU-AP0152SH
Fan tap
Sound pressure
level (dB(A))
H
M
L
37
35
32
Fan tap
Sound pressure
level (dB(A))
M
L
45
41
37
90
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
H
30
M
NC-30
L
20
Approximate threshold of
hearing for continuous noise
NC-20
10
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
90
H
80
70
NC-70
60
NC-60
50
NC-50
40
H
M
NC-40
30
L
NC-30
20
Approximate threshold of
hearing for continuous noise
NC-20
10
63
125
250
500 1000 2000 4000 8000
63
Octave band center frequency (Hz)
125
250
500 1000 2000 4000 8000
Octave band center frequency (Hz)
MMU-AP0182SH
Fan tap
Sound pressure
level (dB(A))
H
M
L
38
36
34
Octave band sound pressure level (dB)
90
80
70
NC-70
60
NC-60
50
NC-50
40
H M
30
L
20
Approximate threshold of
hearing for continuous noise
10
63
125
250
Center
1.5m
NC-40
Microphone
NC-30
NC-20
500 1000 2000 4000 8000
Octave band center frequency (Hz)
9-4 -13
9-4-7. Accessories
1-way (2 series) Air Discharge Cassette Type
Apperarance
Standard accessories
Qty
Shape
Installation Manual
1
—
Heat insulating pipe
2
For heat insulating of pipe connecting section
Installation gauge
—
For positioning of ceiling position
Installation pattern
1
Part name
Use
(Be sure to hand over to customer)
For confirmation of ceiling opening and main unit position
—
Celling panel components
Part name
Qty
Use
RBC-US135PG, 165PG, 265PG type
Ceiling panel
1
—
Intake grille
3
—
Air filter
1
Located in the intake grille and removes dust and
dirt from the air.
Panel installation screw (M5 x 20)
7
For securing the ceiling panel
Screw head insulation
1 set
Prevents condensation from forming on screw heads
9-4 -14
Optional accessories
Remote controller
Model Name
Wired remote controller
RBC-AMT31E
Simple wired remote controller
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E2
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
Central remote controller
TCB-SC642TLE2
ON-OFF controller
TCB-CC163TLE2
9-4 -15
1-way (2 series) Air Discharge Cassette Type
Apperarance
Standard accessories
Qty
Shape
Installation Manual
1
This manual
Installation pattern
1
For check of ceiling opening and unit position
Installation gauge
1
For check of ceiling opening and unit position
(Unit with installation pattern)
Pattern fixing screw
4
Heat insulating pipe
2
Washer
8
Hose band
1
For connecting drain pipe
Flexible hose
1
For adjustment of drain pipe centering
Heat insulator
1
For insulating drain connecting section
Heat insulator
1
For sealing of pipe connection port (With slit)
Heat insulator
1
For sealing of pipe connection port (Without slit)
Part name
M5 x 16
Use
(Be sure to hand over to customer)
For mounting of pattern
For insulating pipe connecting section
M10 x ∅34
For hanging-down of unit
9-4 -16
Optional accessories
Front air discharge unit
TCB-BU21HWE
Auxiliary fresh air Flange
TCB-FF101URE
Ceiling panel
RBC-US21PGE
Name
Model name
Ceiling panel
RBC-US21PGE
Front air discharge unit
TCB-BUS21HWE
Auxiliary fresh air Flange
TCB-FF101URE2
Note
Required accessory
For easy fresh air intake by using the knockout
hole of indoor unit. (dia=100mm)
Remote controller
Model Name
Wired remote controller
RBC-AMT31E
Simple wired remote controller
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E2
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
Central remote controller
TCB-SC642TLE2
ON-OFF controller
TCB-CC163TLE2
9-4 -17
9-5-1. Specifications
50Hz
Specifications (50Hz)
Model name
MMD- AP0071BH AP0091BH AP0121BH AP0151BH AP0181BH AP0241BH AP0271BH AP0301BH AP0361BH AP0481BH
Cooling/Heating capacity (Note 1)
(kW) 2.2/2.5
Power supply
Electrical
characteristics
Running current
3.6/4.0
4.5/5.0
5.6/6.3
0.29
0.34
0.43
0.52
0.61
0.83
0.98
Power consumption (kW)
0.033
0.039
0.050
0.060
0.071
0.107
0.128
0.5
0.59
0.75
0.90
1.05
1.44
1.70
(A)
Main unit
Main unit
Outer
dimension
Suction
ceiling
panel
Zinc hot dipping steel plate
320
Width (mm)
550
700
Depth (mm)
800
Height (mm)
9
Width (mm)
630
780
Depth (mm)
1,350
1,080
1,430
Main unit
(kg)
28
32
43
55
Ceiling panel
(kg)
3.5
4
6
7
Finned tube
Non-flammable insulation
Soundproof/Heat-insulating material
Centrifugal fan
Fan
Standard air flow
(High/Mid/Low)
(m3/h)
480
(420/340)
570
650
780
(490/400) (540/480) (660/540)
Motor
(W)
120
External static pressure
(factory setting)
(Pa)
40
External static pressure
(Pa)
100
Air filter
1,140
(990/870)
1,260
1,620
1,980
(1,080/870) (1,410/1,200) (1,710/1,490)
Standard filter (Long life filter)
Controller
Connecting
pipe
1,000
500
Heat exchanger
Fan unit
8.0/9.0 9.0/10.0 11.2/12.5 14.0/16.0
1 phase 50Hz 230V (220-240V) (Separate power supply for indoor units is required.)
Height (mm)
Total weigh
7.1/8.0
(A)
Starting current
Appearance
2.8/3.2
Remote controller
Gas side
(mm)
Liquid side
(mm)
O
/ 9.5
O
/ 12.7
O
/ 9.5
O
/ 6.4
25 (Polyvinyl chloride tube)
Drain port (Nominal dia. mm)
Sound pressure level (Note 2)
(dB(A))
(High/Mid/Low)
O
/ 15.9
30/28/26
31/29/27
32/30/28
PMV Kit
33/31/29
34/32/29 36/34/32 38/36/32
Not available
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the
actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB
Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB/6oC WB
9-5 -1
60Hz
Specifications (60Hz)
Model name
MMD-
AP0071BH
AP0091BH
AP0121BH
AP0151BH
AP0181BH
AP0241BH
AP0271BH
AP0301BH
AP0361BH
AP0481BH
(kW)
2.2/2.5
2.8/3.2
3.6/4.0
4.5/5.0
5.6/6.3
7.1/8.0
8.0/9.0
9.0/10.0
11.2/12.5
14.0/16.0
Cooling/Heating capacity (Note 1)
1 phase 60Hz 220V (Separate power supply for indoor units is required.)
Power supply
Electrical
characteristics
(A)
0.30
0.35
0.45
0.55
0.64
0.87
1.03
Power consumption (kW)
0.033
0.039
0.050
0.060
0.071
0.107
0.128
0.5
0.59
0.75
0.90
1.05
1.44
1.70
Running current
(A)
Starting current
Appearance
Main unit
Zinc hot dipping steel plate
320
(mm)
Height
Main unit Width
(mm)
Depth
(mm)
800
Height
(mm)
9
Width
(mm)
Depth
(mm)
Outer
dimension
Suction
ceiling
panel
550
700
630
780
1,000
1,350
1,080
1,430
500
Main unit
(kg)
28
32
43
55
Ceiling panel
(kg)
3.5
4
6
7
Total weight
Heat exchanger
Finned tube
Non-flammable insulation
Soundproof/Heat-insulating material
Centrifugal fan
Fan
Standard air flow
(High/Mid/Low)
Fan
unit
(m3/h)
480
(420/340)
570
(490/400)
650
(540/480)
780
(660/540)
1,140
(990/870)
(W)
120
External static pressure
(factory setting)
(Pa)
40
External static pressure
(Pa)
100
Motor
Air filter
1,620
(1,410/1,200)
1,980
(1,710/1,490)
36/34/32
38/36/32
Standard filter (Long life filter)
Controller
Connecting
pipe
1,260
(1,080/870)
Remote controller
Gas side
(mm)
Liquid side
(mm)
O
/ 9.5
O
/ 9.5
O
/ 6.4
25 (Polyvinyl chloride tube)
Drain port (Nominal dia. mm)
Sound pressure level (Note 2)
(High/Mid/Low)
(dB(A))
O
/ 15.9
O
/ 12.7
30/28/26
31/29/27
32/30/28
PMV Kit
33/31/29
34/32/29
Not available
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in
the actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions
Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
O
O
O
9-5 -2
O
O
O
9-5-2. Dimension
MMD-AP0071BH, AP0091BH, AP0121BH, AP0151BH, AP0181BH, AP0241BH,
AP0271BH, AP0301BH, AP0361BH, AP0481BH
Drain pipe connecting port
(Inner ø32 vinyl chloride pipe VP25 connection)
Unit external dimension
40
800
Hanging bolt pitch
700
59
25
41
Hanging bolt pitch A ± 7.5
50
638
498
393
B
41
Refrigerant pipe
connecting port
(Gas side øF)
131
50
215
44
Air
Discharge
49
70 to 270
10-ø4 tapping screw
ø160
142
C
(When attaching
directly)
ø125 knockout hole
(For air intake)
91
150
Refrigerant pipe
connecting port
(Liquid side øG)
50
243
Hanging bolt 4-M10
(Procured locally)
196
Panel C, L
ø26 power supply,
remote controller
wires drawing-out
port
Ceiling open
dimension D
Air
Suction
240
Ceiling opening
470
E
Air Suction
A
Model MMDAP0071BH, AP0091BH, AP0121BH
616
B
D
E
F
G
600
470
9.5
6.4
C
550
350
766
700
500
750
620
12.7
9.4
AP0241BH, AP0271BH, AP0301BH
1066
1000
800
1050
920
15.9
9.5
AP0361BH, AP0481BH
1416
1350
1150
1400
1270
15.9
9.5
AP0151BH, AP0181BH
(Note)
Two of high efficiency filters available
Deodorant filter not available
Wired remote controller
RBC-AMT31E
Simple wired remote controller
RBC-AS21E2
(Note)
Be sure to create a check port at position A as indicated
in the following figure. This is for maintenance of the
equipment.
Air outlet
Wireless remote controller kit
TCB-AX21E2
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
Ceiling opening part
Check port B
450mm
Air filter
700mm for maintenance of air filter
271mm or less
300mm
Check port A
450mm
550mm or less
(150mm)
100mm or less
Drain-up piping
700mm for
maintenance of air filter
9-5 -3
Note: All dimensions are in mm.
R(L) S(N)
U1 U2
Outdoor unit
1 1
2 2
3 3
CN44 1
(BRW) 2
CN66 1
(WHI) 2
Adaputor for wired
remote controller
Wired remote
controller
CN001
(WHI)
BLK
1 1
3
3
1 2 3
1 2 3
CN50
(WHI)
5
5
FM
X Y
(Signal output)
the terminal number.
3.
indicates the control P.C. board.
1 1
2 2
CN101
(BLK)
1 2 3 4 5
CN20 CN70
(BLU) (WHI)
CN73
(RED)
CN80
(GRN)
1
2
Symbol
FM
TA
TC1,TC2,TCJ
DM
FS
RY302
PMV
BLK
GRY
PNK
ORN
GRN
TC1
TC2
: BLACK
: GRAY
: PINK
: ORANGE
: GREEN
Parts name
Fan motor
Indoor temp sensor
Indoor temp sensor
Drain pump motor
Float switch
Drain pump control relay
Pulse Motor Valve
: RED
: WHITE
: YELLOW
: BLUE
: BROWN
TA
TCJ
1 EXCT
2
1
2 PNL
3
1 1
2 2
3 3
1 1
2 2
CN102
(RED)
CN100
(BRN)
1 1
2 2
CN104
(YEL)
3
1 CN34
3 2 1 (RED)
FS
Color identification
RED
WHI
YEL
BLU
BRN
1 2 3 4 5
CN81
(BLK)
indicates the terminal block, the letter inside indicates
1 2 3 4 5 6
1 2
CN60
(WHI)
(Fan drive)
CN32
(WHI)
2 . A dotted line and broken line indicate the wiring on site.
1.
1 2 CN03
1 2 (RED)
Network
adaptor
P.C. board
Network
CN01 1 2 adaptor
(WHI) 1 2 (Option)
3 3
2 2
1 1
CN61
(YEL)
Power
supply
circuit
DC20V
DC15V
DC12V
DC7V
CN33
1 2 3 4 5 (WHI)
Indoor control P.C. board
1 2 3 4 5 6 CN82
1 2 3 4 5 6 (BLU)
6 4 3 1 2 5
6 4 3 1 2 5
PMV
T10 1 2 3 4 5 6
250V~
Fuse
T3.15A
1 2 3 4 5
CN02
(BLU)
TR
1 2 3
1 2 3
Ð
+
Motor drive
circuit
CN333 1
(WHI) 1
CN309
(YEL)
~
~
1 2
1 2
WHI
WHI
BLK
1 2 3
1 2 3
CN41
(BLU)
CN334
(WHI)
1 2
1 2
CN40
(BLU)
P301
250V~
Fuse
T6.3A
RY302
5 4
2 1
5 4 3 2 1
1 2
1 2
CN1
(WHI)
BLK
A B
WHI
U1 U2
BLK
1 1
CN67
(BLK) 2 2
3 3
WHI
RED
1
CN304
(GRY) 2
3
Flow selector
unit earth
screw
Closed end
connector
WHI
Reactor
WHI
Indoor unit power supply
Single phase
220-240V 50Hz
220V 60Hz
Earth screw
Indoor unit
RED
1
3
1 2 2
DM
CN68
(BLU)
BLU
BLU
BLK
9-5 -4
BLK
5 5
4 4
9-5-3. Wiring diagram
Model: MMD-AP0071BH, AP0091BH, AP0121BH, AP0151BH, AP0181BH, AP0241BH
MMD-AP0271BH, AP0301BH, AP0361BH, AP0481BH, AP0561BH
9-5-4. Sensible capacity table
(MMD-AP***BH)
Cooling capacity
Unit
size
007
009
012
015
Outdoor
air temp.
˚CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
16.0˚CWB
23˚CDB
TC
SHC
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
1.9
1.5
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
1.9
2.4
1.9
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.2
2.3
3.1
2.2
4.1
2.8
4.1
2.8
4.1
2.8
4.1
2.8
4.1
2.8
4.1
2.8
4.1
2.8
4.1
2.8
4.1
2.8
4.1
2.8
4.1
2.8
4.1
2.8
4.1
2.8
4.1
2.8
4.0
2.8
3.9
2.7
18.0˚CWB
26˚CDB
TC
SHC
2.1
1.7
2.1
1.7
2.1
1.7
2.1
1.7
2.1
1.7
2.1
1.7
2.1
1.7
2.1
1.7
2.1
1.7
2.1
1.7
2.1
1.7
2.1
1.7
2.1
1.7
2.1
1.7
2.1
1.7
2.0
1.6
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.6
2.0
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.4
2.5
3.4
2.4
4.4
3.0
4.4
3.0
4.4
3.0
4.4
3.0
4.4
3.0
4.4
3.0
4.4
3.0
4.4
3.0
4.4
3.0
4.4
3.0
4.4
3.0
4.4
3.0
4.4
3.0
4.4
3.0
4.3
2.9
4.2
2.8
TC : Total Capacity (kW) SHC : Sensible Heat Capacity (kW)
Indoor air temp.
19.0˚CWB
20.0˚CWB
22.0˚CWB
24.0˚CWB
27˚CDB
28˚CDB
30˚CDB
32˚CDB
TC
SHC
TC
SHC
TC
SHC
TC
SHC
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.2
1.7
2.4
1.7
2.5
1.6
2.1
1.6
2.2
1.6
2.3
1.6
2.4
1.5
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.7
2.1
2.8
2.1
3.0
2.0
3.1
2.0
2.7
2.0
2.8
2.0
2.9
2.0
3.1
1.9
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.5
2.5
3.6
2.4
3.8
2.4
4.0
2.4
3.5
2.4
3.6
2.4
3.8
2.3
3.9
2.3
4.5
3.0
4.6
3.0
4.9
3.0
5.1
2.9
4.5
3.0
4.6
3.0
4.9
3.0
5.1
2.9
4.5
3.0
4.6
3.0
4.9
3.0
5.1
2.9
4.5
3.0
4.6
3.0
4.9
3.0
5.1
2.9
4.5
3.0
4.6
3.0
4.9
3.0
5.1
2.9
4.5
3.0
4.6
3.0
4.9
3.0
5.1
2.9
4.5
3.0
4.6
3.0
4.9
3.0
5.1
2.9
4.5
3.0
4.6
3.0
4.9
3.0
5.1
2.9
4.5
3.0
4.6
3.0
4.9
3.0
5.1
2.9
4.5
3.0
4.6
3.0
4.9
3.0
5.1
2.9
4.5
3.0
4.6
3.0
4.9
3.0
5.1
2.9
4.5
3.0
4.6
3.0
4.9
3.0
5.1
2.9
4.5
3.0
4.6
3.0
4.9
3.0
5.1
2.9
4.5
3.0
4.6
3.0
4.9
3.0
5.1
2.9
4.4
2.9
4.5
2.9
4.8
2.9
5.0
2.8
4.3
2.8
4.4
2.8
4.7
2.8
4.9
2.7
9-5 -5
Cooling capacity (cont.)
Unit
size
018
024
027
030
Outdoor
air temp.
˚CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
16.0˚CWB
23˚CDB
TC
SHC
5.1
3.5
5.1
3.5
5.1
3.5
5.1
3.5
5.1
3.5
5.1
3.5
5.1
3.5
5.1
3.5
5.1
3.5
5.1
3.5
5.1
3.5
5.1
3.5
5.1
3.5
5.1
3.5
5.0
3.4
4.9
3.3
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.3
4.6
6.2
4.4
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.1
5.2
7.0
5.0
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.0
5.7
7.8
5.5
18.0˚CWB
26˚CDB
TC
SHC
5.4
3.7
5.4
3.7
5.4
3.7
5.4
3.7
5.4
3.7
5.4
3.7
5.4
3.7
5.4
3.7
5.4
3.7
5.4
3.7
5.4
3.7
5.4
3.7
5.4
3.7
5.4
3.7
5.3
3.6
5.2
3.5
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.7
4.9
6.6
4.7
7.8
5.6
7.8
5.6
7.8
5.6
7.8
5.6
7.8
5.6
7.8
5.6
7.8
5.6
7.8
5.6
7.8
5.6
7.8
5.6
7.8
5.6
7.8
5.6
7.8
5.6
7.8
5.6
7.6
5.5
7.4
5.3
8.7
6.2
8.7
6.2
8.7
6.2
8.7
6.2
8.7
6.2
8.7
6.2
8.7
6.2
8.7
6.2
8.7
6.2
8.7
6.2
8.7
6.2
8.7
6.2
8.7
6.2
8.7
6.2
8.6
6.1
8.4
5.9
Indoor air temp.
19.0˚CWB
27˚CDB
TC
SHC
5.6
3.7
5.6
3.7
5.6
3.7
5.6
3.7
5.6
3.7
5.6
3.7
5.6
3.7
5.6
3.7
5.6
3.7
5.6
3.7
5.6
3.7
5.6
3.7
5.6
3.7
5.6
3.7
5.5
3.6
5.4
3.5
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.1
5.0
7.0
4.9
6.8
4.7
8.0
5.6
8.0
5.6
8.0
5.6
8.0
5.6
8.0
5.6
8.0
5.6
8.0
5.6
8.0
5.6
8.0
5.6
8.0
5.6
8.0
5.6
8.0
5.6
8.0
5.6
8.0
5.6
7.8
5.5
7.7
5.3
9.0
6.2
9.0
6.2
9.0
6.2
9.0
6.2
9.0
6.2
9.0
6.2
9.0
6.2
9.0
6.2
9.0
6.2
9.0
6.2
9.0
6.2
9.0
6.2
9.0
6.2
9.0
6.2
8.8
6.1
8.6
5.8
9-5 -6
20.0˚CWB
28˚CDB
TC
SHC
5.8
3.7
5.8
3.7
5.8
3.7
5.8
3.7
5.8
3.7
5.8
3.7
5.8
3.7
5.8
3.7
5.8
3.7
5.8
3.7
5.8
3.7
5.8
3.7
5.8
3.7
5.8
3.7
5.7
3.6
5.5
3.5
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.3
5.0
7.2
4.9
7.0
4.7
8.2
5.6
8.2
5.6
8.2
5.6
8.2
5.6
8.2
5.6
8.2
5.6
8.2
5.6
8.2
5.6
8.2
5.6
8.2
5.6
8.2
5.6
8.2
5.6
8.2
5.6
8.2
5.6
8.1
5.5
7.9
5.3
9.3
6.2
9.3
6.2
9.3
6.2
9.3
6.2
9.3
6.2
9.3
6.2
9.3
6.2
9.3
6.2
9.3
6.2
9.3
6.2
9.3
6.2
9.3
6.2
9.3
6.2
9.3
6.2
9.1
6.1
8.9
5.8
22.0˚CWB
30˚CDB
TC
SHC
6.1
3.7
6.1
3.7
6.1
3.7
6.1
3.7
6.1
3.7
6.1
3.7
6.1
3.7
6.1
3.7
6.1
3.7
6.1
3.7
6.1
3.7
6.1
3.7
6.1
3.7
6.1
3.7
6.0
3.6
5.9
3.4
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.7
5.0
7.6
4.9
7.4
4.7
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.5
5.4
8.4
5.2
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.8
6.1
9.6
6.0
9.4
5.8
24.0˚CWB
32˚CDB
TC
SHC
6.4
3.6
6.4
3.6
6.4
3.6
6.4
3.6
6.4
3.6
6.4
3.6
6.4
3.6
6.4
3.6
6.4
3.6
6.4
3.6
6.4
3.6
6.4
3.6
6.4
3.6
6.4
3.6
6.3
3.5
6.1
3.4
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
8.1
4.8
7.9
4.7
7.8
4.6
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
8.9
5.3
8.8
5.1
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.3
6.0
10.1
5.9
9.8
5.6
Cooling capacity (cont.)
Unit
size
036
048
Outdoor
air temp.
˚CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
16.0˚CWB
23˚CDB
TC
SHC
10.2
6.9
10.2
6.9
10.2
6.9
10.2
6.9
10.2
6.9
10.2
6.9
10.2
6.9
10.2
6.9
10.2
6.9
10.2
6.9
10.2
6.9
10.2
6.9
10.2
6.9
10.2
6.9
10.0
6.8
9.8
6.5
12.7
8.7
12.7
8.7
12.7
8.7
12.7
8.7
12.7
8.7
12.7
8.7
12.7
8.7
12.7
8.7
12.7
8.7
12.7
8.7
12.7
8.7
12.7
8.7
12.7
8.7
12.7
8.7
12.5
8.5
12.2
8.2
18.0˚CWB
26˚CDB
TC
SHC
10.9
7.3
10.9
7.3
10.9
7.3
10.9
7.3
10.9
7.3
10.9
7.3
10.9
7.3
10.9
7.3
10.9
7.3
10.9
7.3
10.9
7.3
10.9
7.3
10.9
7.3
10.9
7.3
10.6
7.2
10.4
6.9
13.6
9.2
13.6
9.2
13.6
9.2
13.6
9.2
13.6
9.2
13.6
9.2
13.6
9.2
13.6
9.2
13.6
9.2
13.6
9.2
13.6
9.2
13.6
9.2
13.6
9.2
13.6
9.2
13.3
9.0
13.0
8.7
Indoor air temp.
19.0˚CWB
27˚CDB
TC
SHC
11.2
7.3
11.2
7.3
11.2
7.3
11.2
7.3
11.2
7.3
11.2
7.3
11.2
7.3
11.2
7.3
11.2
7.3
11.2
7.3
11.2
7.3
11.2
7.3
11.2
7.3
11.2
7.3
11.0
7.2
10.8
6.9
14.0
9.2
14.0
9.2
14.0
9.2
14.0
9.2
14.0
9.2
14.0
9.2
14.0
9.2
14.0
9.2
14.0
9.2
14.0
9.2
14.0
9.2
14.0
9.2
14.0
9.2
14.0
9.2
13.7
9.0
13.4
8.7
20.0˚CWB
28˚CDB
TC
SHC
11.5
7.3
11.5
7.3
11.5
7.3
11.5
7.3
11.5
7.3
11.5
7.3
11.5
7.3
11.5
7.3
11.5
7.3
11.5
7.3
11.5
7.3
11.5
7.3
11.5
7.3
11.5
7.3
11.3
7.2
11.1
6.9
14.4
9.2
14.4
9.2
14.4
9.2
14.4
9.2
14.4
9.2
14.4
9.2
14.4
9.2
14.4
9.2
14.4
9.2
14.4
9.2
14.4
9.2
14.4
9.2
14.4
9.2
14.4
9.2
14.1
9.0
13.8
8.7
9-5 -7
22.0˚CWB
30˚CDB
TC
SHC
12.2
7.2
12.2
7.2
12.2
7.2
12.2
7.2
12.2
7.2
12.2
7.2
12.2
7.2
12.2
7.2
12.2
7.2
12.2
7.2
12.2
7.2
12.2
7.2
12.2
7.2
12.2
7.2
12.0
7.1
11.7
6.8
15.3
9.1
15.3
9.1
15.3
9.1
15.3
9.1
15.3
9.1
15.3
9.1
15.3
9.1
15.3
9.1
15.3
9.1
15.3
9.1
15.3
9.1
15.3
9.1
15.3
9.1
15.3
9.1
15.0
8.9
14.6
8.6
24.0˚CWB
32˚CDB
TC
SHC
12.8
7.1
12.8
7.1
12.8
7.1
12.8
7.1
12.8
7.1
12.8
7.1
12.8
7.1
12.8
7.1
12.8
7.1
12.8
7.1
12.8
7.1
12.8
7.1
12.8
7.1
12.8
7.1
12.5
6.9
12.3
6.6
16.0
8.9
16.0
8.9
16.0
8.9
16.0
8.9
16.0
8.9
16.0
8.9
16.0
8.9
16.0
8.9
16.0
8.9
16.0
8.9
16.0
8.9
16.0
8.9
16.0
8.9
16.0
8.9
15.6
8.7
15.3
8.4
Heating capacity
Unit
size
007
009
012
015
Outdoor
air temp.
˚CWB
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
SHC
1.6
1.7
1.8
1.8
1.9
2.0
2.1
2.2
2.3
2.4
2.5
2.6
2.6
2.6
2.6
2.6
2.0
2.1
2.3
2.3
2.5
2.6
2.7
2.9
3.0
3.1
3.2
3.3
3.3
3.3
3.3
3.3
2.5
2.7
2.8
2.9
3.1
3.3
3.4
3.6
3.7
3.9
4.0
4.2
4.2
4.2
4.2
4.2
3.1
3.3
3.6
3.7
3.9
4.1
4.3
4.5
4.7
4.8
5.0
5.2
5.2
5.2
5.2
5.2
SHC : Sensible Heat Capacity (kW)
Indoor air temp. ˚CDB
18.0
20.0
22.0
24.0
SHC
SHC
SHC
SHC
1.5
1.5
1.5
1.4
1.6
1.6
1.6
1.5
1.7
1.7
1.7
1.6
1.8
1.8
1.7
1.7
1.9
1.9
1.8
1.8
2.0
2.0
1.9
1.9
2.1
2.0
2.0
1.9
2.2
2.1
2.1
2.0
2.3
2.2
2.2
2.1
2.4
2.3
2.3
2.2
2.5
2.4
2.4
2.3
2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.0
1.9
1.9
1.8
2.1
2.1
2.0
1.9
2.2
2.2
2.1
2.1
2.3
2.2
2.2
2.1
2.4
2.4
2.3
2.3
2.6
2.5
2.4
2.4
2.7
2.6
2.6
2.5
2.8
2.7
2.7
2.6
2.9
2.9
2.8
2.7
3.0
3.0
2.9
2.8
3.2
3.1
3.0
2.9
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
2.5
2.4
2.3
2.3
2.6
2.6
2.5
2.4
2.8
2.7
2.7
2.6
2.9
2.8
2.7
2.7
3.0
3.0
2.9
2.8
3.2
3.1
3.0
3.0
3.3
3.3
3.2
3.1
3.5
3.4
3.3
3.3
3.7
3.6
3.5
3.4
3.8
3.7
3.6
3.5
3.9
3.9
3.8
3.7
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
3.1
3.0
2.9
2.9
3.3
3.2
3.1
3.0
3.5
3.4
3.3
3.2
3.6
3.5
3.4
3.3
3.8
3.7
3.6
3.5
4.0
3.9
3.8
3.7
4.2
4.1
4.0
3.9
4.4
4.3
4.2
4.1
4.6
4.5
4.4
4.2
4.7
4.6
4.5
4.4
4.9
4.8
4.7
4.6
5.1
5.0
4.9
4.8
5.1
5.0
4.9
4.8
5.1
5.0
4.9
4.8
5.1
5.0
4.9
4.8
5.1
5.0
4.9
4.8
9-5 -8
Heating capacity (cont.)
Unit
size
018
024
027
030
Outdoor
air temp.
˚CWB
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
SHC
3.9
4.2
4.5
4.6
4.9
5.1
5.4
5.6
5.9
6.1
6.3
6.6
6.6
6.6
6.6
6.6
5.0
5.3
5.7
5.8
6.2
6.5
6.8
7.1
7.4
7.7
8.0
8.3
8.3
8.3
8.3
8.3
5.6
6.0
6.4
6.6
7.0
7.3
7.7
8.0
8.4
8.7
9.0
9.4
9.4
9.4
9.4
9.4
6.3
6.7
7.1
7.3
7.7
8.1
8.5
8.9
9.3
9.7
10.0
10.4
10.4
10.4
10.4
10.4
Indoor air temp. ˚CDB
18.0
20.0
22.0
SHC
SHC
SHC
3.9
3.8
3.7
4.1
4.0
3.9
4.4
4.3
4.2
4.5
4.4
4.3
4.8
4.7
4.6
5.0
4.9
4.8
5.3
5.2
5.0
5.5
5.4
5.3
5.8
5.6
5.5
6.0
5.9
5.7
6.2
6.1
5.9
6.4
6.3
6.1
6.4
6.3
6.1
6.4
6.3
6.1
6.4
6.3
6.1
6.4
6.3
6.1
4.9
4.8
4.7
5.2
5.1
5.0
5.6
5.5
5.3
5.7
5.6
5.5
6.1
5.9
5.8
6.4
6.2
6.1
6.7
6.6
6.4
7.0
6.9
6.7
7.3
7.1
7.0
7.6
7.4
7.3
7.9
7.7
7.5
8.2
8.0
7.8
8.2
8.0
7.8
8.2
8.0
7.8
8.2
8.0
7.8
8.2
8.0
7.8
5.5
5.4
5.3
5.9
5.8
5.6
6.3
6.1
6.0
6.5
6.3
6.2
6.8
6.7
6.5
7.2
7.0
6.9
7.5
7.4
7.2
7.9
7.7
7.5
8.2
8.0
7.8
8.5
8.4
8.2
8.9
8.7
8.5
9.2
9.0
8.8
9.2
9.0
8.8
9.2
9.0
8.8
9.2
9.0
8.8
9.2
9.0
8.8
6.1
6.0
5.9
6.6
6.4
6.3
7.0
6.8
6.7
7.2
7.0
6.9
7.6
7.4
7.2
8.0
7.8
7.6
8.4
8.2
8.0
8.8
8.6
8.4
9.1
8.9
8.7
9.5
9.3
9.1
9.9
9.7
9.4
10.2
10.0
9.8
10.2
10.0
9.8
10.2
10.0
9.8
10.2
10.0
9.8
10.2
10.0
9.8
24.0
SHC
3.6
3.8
4.1
4.2
4.4
4.7
4.9
5.1
5.3
5.6
5.8
6.0
6.0
6.0
6.0
6.0
4.6
4.9
5.2
5.3
5.6
5.9
6.2
6.5
6.8
7.1
7.3
7.6
7.6
7.6
7.6
7.6
5.1
5.5
5.8
6.0
6.3
6.7
7.0
7.3
7.6
7.9
8.3
8.6
8.6
8.6
8.6
8.6
5.7
6.1
6.5
6.7
7.0
7.4
7.8
8.1
8.5
8.8
9.2
9.5
9.5
9.5
9.5
9.5
9-5 -9
Heating capacity (cont.)
Unit
size
036
048
Outdoor
air temp.
˚CWB
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
SHC
7.8
8.3
8.9
9.1
9.7
10.2
10.7
11.1
11.6
12.1
12.6
13.0
13.0
13.0
13.0
13.0
10.0
10.7
11.4
11.7
12.4
13.0
13.6
14.3
14.9
15.5
16.1
16.7
16.7
16.7
16.7
16.7
Indoor air temp. ˚CDB
18.0
20.0
22.0
SHC
SHC
SHC
7.7
7.5
7.3
8.2
8.0
7.8
8.7
8.5
8.3
9.0
8.8
8.6
9.5
9.3
9.1
10.0
9.8
9.5
10.5
10.2
10.0
10.9
10.7
10.5
11.4
11.2
10.9
11.9
11.6
11.3
12.3
12.1
11.8
12.8
12.5
12.2
12.8
12.5
12.2
12.8
12.5
12.2
12.8
12.5
12.2
12.8
12.5
12.2
9.8
9.6
9.4
10.5
10.3
10.0
11.1
10.9
10.7
11.5
11.2
11.0
12.1
11.9
11.6
12.8
12.5
12.2
13.4
13.1
12.8
14.0
13.7
13.4
14.6
14.3
14.0
15.2
14.9
14.5
15.8
15.4
15.1
16.3
16.0
15.6
16.3
16.0
15.6
16.3
16.0
15.6
16.3
16.0
15.6
16.3
16.0
15.6
24.0
SHC
7.2
7.6
8.1
8.3
8.8
9.3
9.7
10.2
10.6
11.0
11.5
11.9
11.9
11.9
11.9
11.9
9.1
9.7
10.4
10.7
11.3
11.9
12.4
13.0
13.6
14.1
14.7
15.2
15.2
15.2
15.2
15.2
9-5 -10
9-5-5. Fan characteristics
In case of square duct flange of discharge section
MMD-AP0121BH
Standard air volume: 480m³/h
140
Hi
gh
Hi
gh
120
tic
pre
120
ss
ure
lim
it
0P
a)
ic
pre
ure
1(
nd
ard
sta
tic
pre
ssu
re
(40
Pa
)
(Hi
gh
Lo
)
ws
tat
ic p
res
su
re
(H
Sta
igh
nd
)
ard
pre
ssu
re
(20
Pa
) (L
ow
)
20
60
pr
es
Pa
)
su
re
(4
0P
a)
(H
igh
sta
)
tic
pre
ss
ure
(H
igh
Sta
)
nd
ard
pre
ure
(20
Pa
)
20
0
300
600
(Lo
w)
500
570
700
Air volume (m³/h)
Standard air volume: 650m³/h
Hig
n
tio
ca
pli
p
A
Standard air volume: 780m³/h
140
Hig
h
h st
atic
it
lim
pre
ssu
re 2
(10
0P
a)
0 Pa
80
rd s
tatic
pre
ssu
)
re (
40 P
a) (
Hig
Low
sta
tic
40
nda
rd p
res
pre
ssu
sur
re (
h)
Hig
60
Sta
nda
rd s
pre
ssu
tatic
(70
0P
a)
Pa)
(40
Pa)
(
Hig
Low
sta
tic
pre
ssu
nda
rd
pre
ssu
20
)
re 1
pres
sure
Sta
h)
Low
(10
80
e (2
20
atic
re
40
Hig
0P
a) (
e2
o
ati
h st
Air volume limit (Min)
1 (7
External static pressure (Pa)
ure
Air volume limit (Max)
ress
sur
lic
p
ic p
res
i
nl
Ap
stat
ic p
t
mi
100
High
stat
120
100
Air volume limit (Min)
1(
MMD-AP0181BH
120
External static pressure (Pa)
re
ss
480
140
Sta
su
sta
tic
Lo
w
0P
a)
Long life filter
400
nda
pr
70
rd
2(
sta
da
40
MMD-AP0151BH
re
(20
h)
(Hi
gh)
Pa
)
(Lo
w)
Long life filter
Long life filter
0
400
gh
es
Air volume (m³/h)
60
Hi
St
an
80
ure
10
tic
Long life filter
0
200
Sta
ss
Air volume limit (Max)
40
Air volume limit (Max)
60
Pa
)
pre
it
100
tat
External static pressure (Pa)
Sta
ica
Ap
Hig
70
80
lim
pl
Air volume limit (Min)
Ap
pl
ica
t io
n
n
tio
ss
Air volume limit (Min)
External static pressure (Pa)
2(
10
hs
sta
sta
tic
100
Standard air volume: 570m³/h
140
Air volume limit (Max)
MMD-AP0071BH, AP0091BH
600
650
800
0
500
Air volume (m³/h)
700
Air volume (m³/h)
*Note: “High” and “Low” refers to air flow.
9-5 -11
780
900
MMD-AP0241BH, AP0271BH
Standard air volume: 1140m³/h
140
Stand
ard s
tatic p
ressu
Low s
re (40
tatic p
ressu
Air volume limit (Max)
Air volume limit (Min)
Pa)
Pa) (H
igh)
re (H
Stand
ard pre
ssure
(20
igh)
High
static
press
ure 1
(70 P
a)
80
Stand
a
60
rd sta
tic pre
ssure
Air volume
limit (Max)
1 (70 P
a)
(40 P
a) (Hig
h)
Low
static
press
ure (H
igh)
40
Stand
ard p
Pa) (L
ow)
20
ressu
re (20
Pa) (L
ow)
20
Long life filter
1000
1140
1200
Long life filter
0
900
1300
1100
Air volume (m³/h)
MMD-AP0361BH
MMD-AP0481BH
Standard air volume: 1620m³/h
140
High
static
120
press
ure 2
t
mi
i
nl
(100
Standard air volume: 1980m³/h
140
Hig
h st
120
Pa)
A
100
pres
sure
1 (70
Pa)
Stan
dard
static
press
ure (
40 P
a) (H
igh)
Low
static
press
ure (H
igh)
Air volume limit (Max)
80
High
stat
ic p
ress
ure
1
60
Sta
nda
rd s
tatic
dard
sure
stati
c pre
(40
ssur
0P
a)
(70
Pa)
Pa)
(
h)
e (H
igh)
40
pres
sure
(20 P
a) (L
(20
Pa)
(L
ow)
ow)
20
(10
Hig
Low
dard
pres
pres
sure
Stan
Stan
re 2
80
Air volume limit (Min)
static
External static pressure (Pa)
High
Air volume
limit (Min)
ssu
o
ati
lic
pp
100
0
1200
pre
i
nl
o
ati
A
40
atic
t
mi
c
li
pp
1260 1300
Air volume (m³/h)
20
Long life filter
Long life filter
1620
2000
0
1400
Air volume (m³/h)
1800
1980
Air volume (m³/h)
*Note: “High” and “Low” refers to air flow.
9-5 -12
2200
Air volume limit (Max)
0
800
External static pressure (Pa)
(100
tio
lica
100
ressure
80
60
ure 2
p
tatic p
40
press
t
Ap
High s
60
static
mi
n li
Air volume limit (Min)
100
High
120
External static pressure (Pa)
on
ati
plic
Ap
it
lim
Standard air volume: 1260m³/h
140
High
static
press
ure 2
(100 P
a)
120
External static pressure (Pa)
MMD-AP0301BH
9-5-6. Sound characteristics (NC-Curve)
MMD-AP0071BH, AP0091BH
Fan Tap
Sound pressure level
(dB (A))
H
M
L
30
28
26
Octave band sound pressure level (dB)
90
Microphone
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
H
M
30
NC-30
L
20
NC-20
Audibility limits of
continuous white level
10
63
125
250
500
1000
2000
4000
8000
Octave band center frequency (Hz)
MMD-AP0121BH
MMD-AP0151BH
Fan Tap
Sound pressure level
(dB (A))
H
M
L
31
29
27
Fan Tap
Sound pressure level
(dB (A))
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
H
20
Audibility limits of
continuous white level
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
H
M
L
Audibility limits of
continuous white level
NC-20
10
63
125
250
500
1000
2000
4000
8000
63
MMD-AP0181BH
Fan Tap
Overall level
dB(A)
H
M
L
32
30
28
90
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
H
M
L
Audibility limits of
continuous white level
NC-20
10
63
125
250
500
1000
2000
4000
125
250
500
1000
2000
4000
Octave band center frequency (Hz)
Octave band center frequency (Hz)
Octave band sound pressure level (dB)
L
27
80
20
NC-20
M
L
10
20
M
29
90
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
90
H
31
8000
Octave band center frequency (Hz)
9-5 -13
8000
MMD-AP0241BH, AP0271BH
Fan Tap
Sound pressure level
(dB(A))
MMD-AP0301BH
H
M
L
33
31
29
Fan Tap
Sound pressure level
(dB(A))
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
continuous white level
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
NC-20
Audibility limits of
continuous white level
NC-20
10
63
125
250
500
1000
2000
4000
8000
63
125
250
500
1000
2000
4000
8000
Octave band center frequency (Hz)
Octave band center frequency (Hz)
MMD-AP0361BH
MMD-AP0481BH, AP0561BH
Fan Tap
Sound pressure level
(dB(A))
H
M
L
36
34
32
Fan Tap
Sound pressure level
(dB(A))
90
90
80
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
L
29
80
10
20
M
32
90
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
90
H
34
NC-20
Audibility limits of
continuous white level
10
H
M
L
38
36
32
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
continuous white level
NC-20
10
63
125
250
500
1000
2000
4000
8000
63
125
250
500
1000
2000
4000
Octave band center frequency (Hz)
Octave band center frequency (Hz)
9-5 -14
8000
9-5-7. Accessories
Apperarance
Standard accessories
Part name
Qty
Installation
Manual
1
Insulated
pipe
2
Shape
Use
Part name
Washer
Qty
Shape
8
For heat insulating pipe
connecting section
Remote controller
Model Name
Wired remote controller
RBC-AMT31E
Simple wired remote controller
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E2
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
Central remote controller
TCB-SC642TLE2
ON-OFF controller
TCB-CC163TLE2
9-5 -15
Use
For hanging down the unit
Optional accessories
High Efficiency Filter 65
TCB-UFM11BFCE
TCB-UFM21BFCE
High Efficiency Filter 90
TCB-UFH51BFCE
TCB-UFH61BFCE
Standard filter
and filter frame
Filter Chamber
TCB-FC281BE, TCB-FC501BE
TCB-FC801BE, TCB-FC1401BE
High Efficiency Filter 65
TCB-UFM11BE
TCB-UFM21BE
TCB-UFM31BE
TCB-UFM41BE
Filter kit for underside
TCB-FK281BE, TCB-FK501BE
TCB-FK801BE, TCB-FK1401BE
High Efficiency Filter 90
TCB-UFH51BE
TCB-UFH61BE
TCB-UFH71BE
TCB-UFH81BE
Suction Canvas
TCB-CA281BE, TCB-CA501BE
TCB-CA801BE, TCB-CA1401BE
Ceiling panel
9-5 -16
Name
Model name
Note
TCB-UFM11BFCE
High Efficiency Filter 65
(For rear suction)
TCB-UFM11BFCE(2 pcs.) Dust collecting effect :65%
(NBS Colorimentric method)
TCB-UFM21BFCE
TCB-UFM21BFCE(2 pcs.)
TCB-UFH51BFCE
High Efficiency Filter 90
(For rear suction)
TCB-UFH51BFCE(2 pcs.) Dust collecting effect :90%
(NBS Colorimentric method)
TCB-UFH61BFCE
TCB-UFH61BFCE(2 pcs.)
TCB-FC281BE
Filter Chamber
(For rear suction)
TCB-FC501BE
For high efficiency filter
TCB-FC801BE
TCB-FC1401BE
TCB-UFM11BE
High Efficiency Filter 65
(For underside suction)
TCB-UFM21BE
Dust collecting effect :65%
(NBS Colorimentric method)
TCB-UFM31BE
TCB-UFM41BE
TCB-UFH51BE
High Efficiency Filter 90
(For underside suction)
TCB-UFH61BE
Dust collecting effect :90%
(NBS Colorimentric method)
TCB-UFH71BE
TCB-UFH81BE
RBC-UD281PE(W)
Ceiling panel
(Half panel for underside
suction)
RBC-UD501PE(W)
RBC-UD801PE(W)
RBC-UD1401PE(W)
TCB-CA281BE
Suction Canvas
(For underside suction)
TCB-CA501BE
TCB-CA801BE
Adjustment height of the suction canvas is
more 40mm and 100mm
TCB-CA1401BE
TCB-FK281BE
TCB-FK501BE
Filter kit for underside
TCB-FK801BE
Kit of underside prefilter &
shielding plate of rear suction
TCB-FK1401BE
9-5 -17
9-6-1. Specifications
50Hz
Specifications (50Hz)
Model name
Cooling/Heating capacity (Note 1)
MMD-
AP0071SPH
AP0091SPH
AP0121SPH
AP0151SPH
AP0181SPH
(kW)
2.2/2.5
2.8/3.2
3.6/4.0
4.5/5.0
5.6/6.3
Power supply
Running current
Electrical
characteristics
Power consumption
Starting current
1 phase 50Hz 230V (220-240V) (Separate power supply for indoor units is required.)
(A)
0.29
0.29
0.31
0.32
0.39
(kW)
0.039
0.039
0.043
0.045
0.054
(A)
0.51
0.51
0.54
0.56
0.68
23
23
690/600/520
780/680/580
Appearance
Outer
dimension
Zinc hot dipping steel plate
Height x Width x Depth
(mm)
(kg)
Total weight
210/845/645
22
22
Heat exchanger
Finned tube
Soundproof/Heat-insulating material
Polyethylene foam + Polyurethane foam
Fan
Centrifugal fan
Standard air flow
(High/Mid./Low)
Fan
unit
22
(m3/h)
Motor
600/520/450
540/470/400
(W)
60
External static pressure
(Factory setting)
(Pa)
6
5
4
External static pressure
(Pa)
6-16-31-46 (4steps)
5-15-30-40 (4steps)
4-14-29-44 (4steps)
Air filter pressure loss
(Pa)
4
5
6
Air filter
Standard filter (Long life filter)
Controller
Connecting
pipe
Remote controller
Gas side
(mm)
Liquid side
(mm)
Drain port
Sound pressure
level (Note 2)
(High/Mid/Low)
PMV Kit
O
/ 9.5
O
/ 12.7
O
/ 6.4
(Nominal dia. mm)
25 (Polyvinyl chloride tube : External dia.32 Internal dia.25)
Under air inlet
(dB(A))
36/33/30
38/35/32
39/36/33
40/38/36
Back air inlet
(dB(A))
28/26/24
29/27/25
32/30/28
33/31/29
Available
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the
actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB
Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB/6oC WB
9-6 -1 (Revised edition in 7.Apr.2006)
60Hz
Specifications (60Hz)
Model name
Cooling/Heating capacity (Note 1)
MMD-
AP0071SPH
AP0091SPH
AP0121SPH
AP0151SPH
AP0181SPH
(kW)
2.2/2.5
2.8/3.2
3.6/4.0
4.5/5.0
5.6/6.3
Power supply
Electrical
characteristics
Running current
Power consumption
Starting current
1 phase 60Hz 220V (Separate power supply for indoor units is required.)
(A)
0.27
0.27
0.30
0.31
0.37
(kW)
0.037
0.037
0.041
0.043
0.052
(A)
0.47
0.47
0.53
0.54
0.65
23
23
690/600/520
780/680/580
Appearance
Outer
dimension
Zinc hot dipping steel plate
Height x Width x Depth
(mm)
(kg)
Total weight
210/845/645
22
22
22
Heat exchanger
Finned tube
Soundproof/Heat-insulating material
Polyethylene foam + Polyurethane foam
Fan
Centrifugal fan
Standard air flow
(High/Mid./Low)
Fan
unit
(m3/h)
Motor
600/520/450
540/470/400
(W)
60
External static pressure
(Factory setting)
(Pa)
6
5
4
External static pressure
(Pa)
6-16-31-46 (4steps)
5-15-30-45 (4steps)
4-14-29-44 (4steps)
Air filter pressure loss
(Pa)
4
5
6
Air filter
Standard filter (Long life filter)
Controller
Connecting
pipe
Remote controller
Gas side
(mm)
Liquid side
(mm)
Drain port
Sound pressure
level (Note 2)
(High/Mid/Low)
O
/ 9.5
O
/ 12.7
O
/ 6.4
25 (Polyvinyl chloride tube : External dia.32 Internal dia.25)
(Nominal dia. mm)
Under air inlet
(dB(A))
36/33/30
38/35/32
39/36/33
40/38/36
Back air inlet
(dB(A))
28/26/24
29/27/25
32/30/28
33/31/29
PMV Kit
Available
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the
actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB
Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB/6oC WB
9-6 -2
(Revised edition in 7.Apr.2006)
9-6-2. Dimension
MMD-AP0071SPH, AP0091SPH, AP0121SPH, AP0151SPH, AP0181SPH
210
21
21
803 (inside)
103
Air filter
Refrigerant piping
511
645
19
4-O
/4
67
20 21
168
(inside)
57
21
845
359
372
422
502
168
40
67
120
O
/9
80
2
31
805
80
59
33
163
910
Fresh air inlet
(Knock-out hole)
Drain-up port
Hanger plate
Air inlet connecting flange (Field supply)
100
266.5
100
805
12.5
100
100
100
100
100
100
45.3
100
825
Wireless remote controller kit
TCB-AX21E2
n=24 M5 (O/ 4.2 mounting hole)
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
12.5
100
100
100
100
100
100
100
100
188.6
44.3
100
170
44.3
805
12.5
Wired remote controller
RBC-AMT31E
Simple wired remote controller
RBC-AS21E2
12.5
100
Rearside
286.8
41.5
8.2 or less
Underside
825
n=22 M5 (O/ 4.2 mounting hole)
9-6 -3
*China only
21
MMD-AP007SPH-C, AP0091SPH-C, AP0121SPH-C, AP0151SPH-C, AP0181SPH-C,
MMD-AP0071SH-C, AP0091SH-C, AP0121SH-C, AP0151SH-C, AP0181SH-C
210
803 (inside)
21
21
Natural drain port
103
Refrigerant
piping
80
511
645
359
372
422
502
805
910
59
40
168
120
67
80
31
146
O
/9
2
4-O/ 4
19
67
20 21
168 (inside)
57
845
33
163
Fresh air inlet
(Knock-out hole)
Drain-up port
(SPH model only)
Hanger plate
Air inlet connecting flange (Field supply)
100
266.5
100
805
12.5
286.8
41.5
8.2 or less
Underside
Wired remote controller
RBC-AMT31E
12.5
100
100
100
100
100
100
100
45.3
100
825
Simple wired remote controller
RBC-AS21E2
n=24 M5 (O/ 4.2 mounting hole)
Wireless remote controller kit
TCB-AX21E2
805
12.5
12.5
100
100
100
100
100
100
100
100
825
n=22 M5 (O/ 4.2 mounting hole)
9-6 -4
44.3
188.6
100
170
44.3
Rearside
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
9-6-3. Wiring diagram
MMD-AP0071SPH(SH), AP0091SPH(SH), AP0121SPH(SH), AP0151SPH(SH), AP0181SPH(SH)
9-6 -5
9-6-4. Sensible capacity table
(MMD-AP***SPH)
Cooling capacity
Unit
size
007
009
012
Outdoor
air temp.
°CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
16.0°CWB
23°CDB
TC
SHC
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
2.0
1.7
1.9
1.6
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
2.5
1.9
2.4
1.9
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.2
2.3
3.1
2.2
18.0°CWB
26°CDB
TC
SHC
2.1
1.8
2.1
1.8
2.1
1.8
2.1
1.8
2.1
1.8
2.1
1.8
2.1
1.8
2.1
1.8
2.1
1.8
2.1
1.8
2.1
1.8
2.1
1.8
2.1
1.8
2.1
1.8
2.1
1.8
2.0
1.7
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.7
2.1
2.6
2.0
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.4
2.5
3.4
2.4
TC : Total Capacity (kW) SHC : Sensible Heat Capacity (kW)
Indoor air temp.
19.0°CWB
20.0°CWB
22.0°CWB
24.0°CWB
27°CDB
28°CDB
30°CDB
32°CDB
TC
SHC
TC
SHC
TC
SHC
TC
SHC
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.3
1.8
2.4
1.8
2.5
1.7
2.2
1.8
2.2
1.8
2.4
1.7
2.5
1.7
2.1
1.7
2.2
1.7
2.3
1.7
2.4
1.6
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.8
2.1
2.9
2.1
3.1
2.1
3.2
2.0
2.7
2.1
2.8
2.1
3.0
2.0
3.1
2.0
2.7
2.0
2.8
2.0
2.9
2.0
3.1
1.9
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.5
2.5
3.6
2.4
3.8
2.4
4.0
2.4
3.5
2.4
3.6
2.4
3.8
2.3
3.9
2.3
9-6 -6
Cooling capacity (cont.)
Unit
size
015
018
Outdoor
air temp.
°CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
16.0°CWB
23°CDB
TC
SHC
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.0
3.0
3.9
2.8
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.0
3.6
4.9
3.5
18.0°CWB
26°CDB
TC
SHC
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.3
3.1
4.2
3.0
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.3
3.8
5.2
3.7
Indoor air temp.
19.0°CWB
27°CDB
TC
SHC
4.5
3.2
4.5
3.2
4.5
3.2
4.5
3.2
4.5
3.2
4.5
3.2
4.5
3.2
4.5
3.2
4.5
3.2
4.5
3.2
4.5
3.2
4.5
3.2
4.5
3.2
4.5
3.2
4.4
3.1
4.3
3.0
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.6
3.9
5.5
3.8
5.4
3.7
20.0°CWB
28°CDB
TC
SHC
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.6
3.2
4.5
3.1
4.4
3.0
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.8
3.9
5.7
3.8
5.5
3.7
9-6 -7
22.0°CWB
30°CDB
TC
SHC
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.9
3.2
4.8
3.1
4.7
3.0
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.1
3.9
6.0
3.8
5.9
3.6
24.0°CWB
32°CDB
TC
SHC
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.1
3.1
5.0
3.0
4.9
2.9
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.4
3.8
6.3
3.7
6.1
3.6
Heating capacity
Unit
size
007
009
012
Outdoor
air temp.
°CWB
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
SHC
1.6
1.7
1.8
1.8
1.9
2.0
2.1
2.2
2.3
2.4
2.5
2.6
2.6
2.6
2.6
2.6
2.0
2.1
2.3
2.3
2.5
2.6
2.7
2.9
3.0
3.1
3.2
3.3
3.3
3.3
3.3
3.3
2.5
2.7
2.8
2.9
3.1
3.3
3.4
3.6
3.7
3.9
4.0
4.2
4.2
4.2
4.2
4.2
SHC : Sensible Heat Capacity (kW)
Indoor air temp. °CDB
18.0
20.0
22.0
24.0
SHC
SHC
SHC
SHC
1.5
1.5
1.5
1.4
1.6
1.6
1.6
1.5
1.7
1.7
1.7
1.6
1.8
1.8
1.7
1.7
1.9
1.9
1.8
1.8
2.0
2.0
1.9
1.9
2.1
2.0
2.0
1.9
2.2
2.1
2.1
2.0
2.3
2.2
2.2
2.1
2.4
2.3
2.3
2.2
2.5
2.4
2.4
2.3
2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.0
1.9
1.9
1.8
2.1
2.1
2.0
1.9
2.2
2.2
2.1
2.1
2.3
2.2
2.2
2.1
2.4
2.4
2.3
2.3
2.6
2.5
2.4
2.4
2.7
2.6
2.6
2.5
2.8
2.7
2.7
2.6
2.9
2.9
2.8
2.7
3.0
3.0
2.9
2.8
3.2
3.1
3.0
2.9
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
2.5
2.4
2.3
2.3
2.6
2.6
2.5
2.4
2.8
2.7
2.7
2.6
2.9
2.8
2.7
2.7
3.0
3.0
2.9
2.8
3.2
3.1
3.0
3.0
3.3
3.3
3.2
3.1
3.5
3.4
3.3
3.3
3.7
3.6
3.5
3.4
3.8
3.7
3.6
3.5
3.9
3.9
3.8
3.7
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
9-6 -8
Heating capacity (cont.)
Unit
size
015
018
Outdoor
air temp.
°CWB
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
SHC
3.1
3.3
3.6
3.7
3.9
4.1
4.3
4.5
4.7
4.8
5.0
5.2
5.2
5.2
5.2
5.2
3.9
4.2
4.5
4.6
4.9
5.1
5.4
5.6
5.9
6.1
6.3
6.6
6.6
6.6
6.6
6.6
Indoor air temp. °CDB
18.0
20.0
22.0
SHC
SHC
SHC
3.1
3.0
2.9
3.3
3.2
3.1
3.5
3.4
3.3
3.6
3.5
3.4
3.8
3.7
3.6
4.0
3.9
3.8
4.2
4.1
4.0
4.4
4.3
4.2
4.6
4.5
4.4
4.7
4.6
4.5
4.9
4.8
4.7
5.1
5.0
4.9
5.1
5.0
4.9
5.1
5.0
4.9
5.1
5.0
4.9
5.1
5.0
4.9
3.9
3.8
3.7
4.1
4.0
3.9
4.4
4.3
4.2
4.5
4.4
4.3
4.8
4.7
4.6
5.0
4.9
4.8
5.3
5.2
5.0
5.5
5.4
5.3
5.8
5.6
5.5
6.0
5.9
5.7
6.2
6.1
5.9
6.4
6.3
6.1
6.4
6.3
6.1
6.4
6.3
6.1
6.4
6.3
6.1
6.4
6.3
6.1
24.0
SHC
2.9
3.0
3.2
3.3
3.5
3.7
3.9
4.1
4.2
4.4
4.6
4.8
4.8
4.8
4.8
4.8
3.6
3.8
4.1
4.2
4.4
4.7
4.9
5.1
5.3
5.6
5.8
6.0
6.0
6.0
6.0
6.0
9-6 -9
9-6-5. Fan characteristics
MMD-AP0071SPH
MMD-AP0091SPH
MMD-AP0121SPH
Standard air volume : 540m3/h
Standard air volume : 600m3/h
60
60
50
Upper limit of
external static
pressure(35Pa)
High (35Pa)
40
Lower limit of external
static pressure (50Pa)
Low (50Pa)
Upper limit of
external static
pressure(20Pa)
30
High (20Pa)
20
Upper limit of
external static
pressure(10Pa)
Low (35Pa)
Lower limit of external
static pressure (35Pa)
External static pressure (Pa)
External static pressure (Pa)
50
High (50Pa)
High (50Pa)
Upper limit of external
static pressure(50Pa)
Upper limit of external
static pressure(50Pa)
High (35Pa)
40
Low (50Pa)
Lower limit of external
static pressure (50Pa)
Upper limit of
external static
pressure(35Pa)
30
High (20Pa)
Low (35Pa)
20
Upper limit of
external static
pressure(20Pa)
Lower limit of external
static pressure (35Pa)
High (10Pa)
High (10Pa)
10
Low (20Pa)
Upper limit of
external static
pressure(10Pa)
Lower limit of external
static pressure (20Pa)
Low (10Pa)
0
300
400
Low (20Pa)
10
500
600
0
300
700
400
Air Volume (m3/h)
500
600
MMD-AP0181SPH
Standard air volume : 690m3/h
High (50Pa)
High (50Pa)
Upper limit of external
static pressure(50Pa)
50
Upper limit of
external static
pressure(35Pa)
Lower limit of external
static pressure (50Pa)
Low (50Pa)
High (20Pa)
20
Low (35Pa)
Upper limit of
external static
pressure(20Pa)
Upper limit of
external static
pressure(10Pa)
0
400
500
Upper limit of external
static pressure(50Pa)
High (35Pa)
Lower limit of external
static pressure (35Pa)
External static pressure (Pa)
External static pressure (Pa)
50
10
Standard air volume : 780m3/h
60
60
30
700
Air Volume (m3/h)
MMD-AP0151SPH
40
Lower limit of external
static pressure (20Pa)
Low (10Pa)
High (35Pa)
40
Low (50Pa)
30
20
10
Low (20Pa)
Lower limit of external
static pressure (20Pa)
0
400
Air Volume (
m3
Upper limit of
external static
pressure(20Pa)
Lower limit of
external static
pressure (35Pa)
Upper limit of
external static
pressure(10Pa)
Low (20Pa)
Low (10Pa)
Low (10Pa)
700
High (20Pa)
Low (35Pa)
High (10Pa)
600
Lower limit of
external static
pressure (50Pa)
Upper limit of
external static
pressure(35Pa)
800
500
High (10Pa)
600
700
Air Volume (m3/h)
/h)
9-6 -10
800
Lower limit of
external static
pressure (20Pa)
900
(Filter attached)
MMD-AP0071SPH
MMD-AP0091SPH
MMD-AP0121SPH
Standard air volume : 540m3/h
Standard air volume : 600m3/h
60
60
High (50Pa)
High (50Pa)
Upper limit of external
static pressure(50Pa)
50
50
Lower limit of external
static pressure (50Pa)
Upper limit of external
static pressure(50Pa)
Lower limit of externa
static pressure (50Pa)
Upper limit of
external static
pressure(35Pa)
30
Low (50Pa)
Lower limit of external
static pressure (35Pa)
Low (35Pa)
20
High (20Pa)
Upper limit of
external static
pressure(20Pa)
External static pressure (Pa)
External static pressure (Pa)
Low (50Pa)
40
40
Upper limit o
external static
pressure(35Pa)
30
Low (35Pa)
Upper limit o
external static
pressure(20Pa)
20
High (20Pa)
Lower limit of external
static pressure (20Pa)
Lower limit of extern
static pressure (20Pa)
Low (20Pa)
Low (20Pa)
10
10
Upper limit of
external static
pressure(10Pa)
0
300
High (10Pa)
Upper limit o
external static
pressure(10Pa)
High (10Pa)
Standard filter
pressure loss
Low (10Pa)
400
500
600
700
400
500
600
700
Air Volume (m3/h)
MMD-AP0151SPH
MMD-AP0181SPH
Standard air volume : 690m3/h
60
Standard air volume : 780m3/h
60
High (50Pa)
High (50Pa)
Upper limit of external
static pressure(50Pa)
Upper limit of external
static pressure(50Pa)
50
50
Upper limit of external
static pressure(35Pa)
Lower limit of external
static pressure (50Pa)
Lower limit of external
static pressure (35Pa)
Low (50Pa)
30
Upper limit of
external static
pressure(20Pa)
High (20Pa)
Low (35Pa)
20
High (10Pa)
Upper limit of
external static
pressure(10Pa)
External static pressure (Pa)
40
Lower limit of
external static
pressure (50Pa)
Upper limit of external
static pressure(35Pa)
High (35Pa)
External static pressure (Pa)
Standard filter
pressure loss
Low (10Pa)
0
300
Air Volume (m3/h)
10
Lower limit of external
static pressure (35Pa)
High (35Pa)
40
Low (50Pa)
Lower limit of
external static
pressure (35Pa)
High (35Pa)
30
Low (35Pa)
20
Lower limit of externa
static pressure (20Pa)
Upper limit of external
static pressure(20Pa)
Low (20Pa)
10
High (20Pa)
Lower limit of
external static
pressure (20Pa)
Upper limit of
external static
pressure(10Pa)
High (10Pa)
Low (20Pa)
Low (10Pa)
0
400
Standard filter
pressure loss
500
600
700
800
0
400
Air Volume (m3/h)
Standard filter
pressure loss
Low (10Pa)
500
600
700
Air Volume (m3/h)
9-6 -11
800
900
CHINA model
MMD-AP0071SPH-C, SH-C
MMD-AP0091SPH-C, SH-C
Standard air volume : 540m 3/h
60
High (50Pa)
Upper limit of external
static pressure(50Pa)
40
High (35Pa)
Lower limit of external
static pressure (50Pa)
Low (50Pa)
Upper limit of
external static
pressure(35Pa)
30
High (20Pa)
Upper limit of
external static
pressure(20Pa)
20
Low (35Pa)
Lower limit of external
static pressure (35Pa)
static
Upper limit of
external static
pressure(35Pa)
pressure (Pa )
50
External
pressure (Pa)
s tatic
Standard air volume : 600m 3/h
60
High (50Pa)
Upper limit of external
static pressure(50Pa)
50
External
MMD-AP0121SPH-C, SH-C
0
300
Upper limit of
external static
pressure(35Pa)
20
Upper limit of
external static
pressure(20Pa)
500
Lower limit of external
static pressure (50Pa)
High (20Pa)
Low (35Pa)
Lower limit of external
static pressure (35Pa)
High (10Pa)
Lower limit of external
static pressure (20Pa)
Low (10Pa)
400
30
10
Low (20Pa)
Upper limit of
external static
pressure(10Pa)
Low (50Pa)
Low (20Pa)
High (10Pa)
10
High (35Pa)
40
600
0
300
700
Lower limit of external
static pressure (20Pa)
Upper limit of external
static pressure(10Pa)
Low (10Pa)
400
500
600
Air Volume ( m3/h)
Air Volume ( m3/h)
MMD-AP0151SPH-C, SH-C
MMD-AP0181SPH-C, SH-C
Standard air volume : 690m 3/h
60
Standard air volume : 780m 3/h
60
High (50Pa)
Upper limit of external
static pressure(50Pa)
50
40
Low (50Pa)
Lower limit of external
static pressure (50Pa)
30
High (20Pa)
20
Lower limit of extern
static pressure (35Pa)
Low (35Pa)
High (35Pa)
40
Low (50Pa)
Lower limit of
external static
pressure (50Pa)
30
Low (35Pa)
20
Upper limit of external
static pressure(20Pa)
High (20Pa)
Lower limit of extern
static pressure (35Pa)
High (10Pa)
Upper limit of
external static
pressure(20Pa)
0
400
Upper limit of external
static pressure(35Pa)
pressure
( Pa)
High (35Pa)
Ext ernal static
s tatic
pressure ( Pa)
Upper limit of external
static pressure(35Pa)
External
High (50Pa)
Upper limit of external
static pressure(50Pa)
50
10
700
Upper limit of
external static
pressure(10Pa)
500
High (10Pa)
10
Low (20Pa)
Low (20Pa)
Lower limit of external
static pressure (20Pa)
Upper limit of external
static pressure(10Pa)
Low (10Pa)
600
700
0
400
800
Air Volume ( m3/h)
500
Lower limit of exte
static pressure (20Pa)
Low (10Pa)
600
700
800
900
Air Volume ( m3/h)
9-6 -12
(Revised edition in 7.Apr.2006)
9-6-6. Sound characteristics (NC-Curve)
MMD-AP0071SPH/SH ,
MMD-AP0091SPH/SH
Measuring location
2m
1m
Duct
Duct
Air outlet
Rear air intake
Air inlet
Center
1.5m
Microphone
External static pressure 10Pa
H
M
L
28
26
24
Fan tap
Sound pressure
level (dB(A))
70
70
60
60
50
NC-50
40
NC-40
30
NC-30
H
M
20
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
Fan tap
Sound pressure
level (dB(A))
External static pressure 20Pa
M
L
29
27
25
50
NC-50
40
NC-40
30
NC-30
H
M
20
L
NC-20
L
NC-20
Approximate threshold of
hearing for continuous noise
Approximate threshold of
hearing for continuous noise
10
10
63
125
250
500
1000
2000
4000
63
8000
125
External static pressure 35Pa
Fan tap
Sound pressure
level (dB(A))
500
1000
2000
4000
8000
External static pressure 50Pa
H
M
L
30
28
26
Fan tap
Sound pressure
level (dB(A))
70
60
60
50
NC-50
40
NC-40
30
NC-30
H
M
L
Octave band sound pressure level (dB)
70
20
250
Octave band center frequency (Hz)
Octave band center frequency (Hz)
Octave band sound pressure level (dB)
H
H
M
L
32
29
27
50
NC-50
40
NC-40
H
30
NC-30
M
L
20
NC-20
NC-20
Approximate threshold of
hearing for continuous noise
Approximate threshold of
hearing for continuous noise
10
10
63
125
250
500
1000
2000
4000
8000
63
Octave band center frequency (Hz)
125
250
500
1000
2000
Octave band center frequency (Hz)
9-6 -13
4000
8000
MMD-AP0121SPH/SH
Measuring location
2m
1m
Duct
Duct
Air outlet
Rear air intake
Air inlet
Center
1.5m
Microphone
External static pressure 10Pa
H
M
L
29
27
25
Fan tap
Sound pressure
level (dB(A))
70
70
60
60
50
NC-50
40
NC-40
30
H
NC-30
M
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
Fan tap
Sound pressure
level (dB(A))
External static pressure 20Pa
L
20
H
M
L
30
28
26
50
NC-50
40
NC-40
H
30
NC-30
M
L
20
NC-20
NC-20
Approximate threshold of
hearing for continuous noise
Approximate threshold of
hearing for continuous noise
10
10
63
125
250
500
1000
2000
4000
8000
63
125
Octave band center frequency (Hz)
External static pressure 35Pa
H
M
L
31
29
27
Fan tap
Sound pressure
level (dB(A))
70
70
60
60
50
NC-50
40
NC-40
H
30
500
1000
2000
4000
8000
External static pressure 50Pa
NC-30
M
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
Fan tap
Sound pressure
level (dB(A))
250
Octave band center frequency (Hz)
H
M
L
32
30
28
50
NC-50
40
NC-40
H
30
NC-30
M
L
L
20
20
NC-20
NC-20
Approximate threshold of
hearing for continuous noise
Approximate threshold of
hearing for continuous noise
10
10
63
125
250
500
1000
2000
4000
8000
63
Octave band center frequency (Hz)
125
250
500
1000
2000
Octave band center frequency (Hz)
9-6 -14
4000
8000
MMD-AP0151SPH/SH
Measuring location
2m
1m
Duct
Duct
Air outlet
Air inlet
Rear air intake
Center
1.5m
Microphone
External static pressure 10Pa
H
M
L
32
30
28
Fan tap
Sound pressure
level (dB(A))
70
70
60
60
50
NC-50
40
NC-40
30
H
NC-30
M
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
Fan tap
Sound pressure
level (dB(A))
External static pressure 20Pa
M
L
33
31
29
50
NC-50
40
NC-40
30
L
20
NC-20
NC-20
Approximate threshold of
hearing for continuous noise
Approximate threshold of
hearing for continuous noise
10
63
125
250
500
1000
2000
4000
10
8000
63
125
Octave band center frequency (Hz)
500
M
L
34
32
30
Fan tap
Sound pressure
level (dB(A))
70
60
60
50
NC-50
40
NC-40
H
NC-30
M
Octave band sound pressure level (dB)
70
M
L
35
33
31
NC-50
40
NC-40
H
30
500
NC-30
M
20
NC-20
Approximate threshold of
hearing for continuous noise
10
250
8000
50
Approximate threshold of
hearing for continuous noise
125
4000
L
NC-20
63
2000
H
L
20
1000
External static pressure 50Pa
H
30
250
Octave band center frequency (Hz)
External static pressure 35Pa
Fan tap
Sound pressure
level (dB(A))
NC-30
H
M
L
20
Octave band sound pressur level (dB)
H
1000
2000
4000
8000
10
63
Octave band center frequency (Hz)
125
250
500
1000
2000
Octave band center frequency (Hz)
9-6 -15
4000
8000
MMD-AP0181SPH/SH
Measuring location
2m
1m
Duct
Duct
Air outlet
Rear air intake
Air inlet
Center
1.5m
Microphone
External static pressure 10Pa
H
M
L
33
31
29
Fan tap
Sound pressure
level (dB(A))
70
70
60
60
50
NC-50
40
NC-40
H
30
NC-30
M
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
Fan tap
Sound pressure
level (dB(A))
External static pressure 20Pa
H
M
L
34
32
30
50
NC-50
40
NC-40
H
30
M
L
NC-30
L
20
20
NC-20
NC-20
Approximate threshold of
hearing for continuous noise
Approximate threshold of
hearing for continuous noise
10
10
63
125
250
500
1000
2000
4000
8000
63
125
Octave band center frequency (Hz)
External static pressure 35Pa
500
1000
2000
4000
8000
External static pressure 50Pa
H
M
L
35
33
31
Fan tap
Sound pressure
level (dB(A))
70
70
60
60
50
NC-50
40
NC-40
H
30
NC-30
M
L
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
Fan tap
Sound pressure
level (dB(A))
250
Octave band center frequency (Hz)
20
H
M
L
36
34
32
50
NC-50
40
NC-40
H
30
NC-30
M
L
20
NC-20
NC-20
Approximate threshold of
hearing for continuous noise
Approximate threshold of
hearing for continuous noise
10
10
63
125
250
500
1000
2000
4000
8000
63
Octave band center fequency (Hz)
125
250
500
1000
2000
Octave band center frequency (Hz)
9-6 -16
4000
8000
2m
MMD-AP0071SPH/SH ,
MMD-AP0091SPH/SH
Duct
Air outlet
Measuring location
Center
1.5m
Under air intake
Air inlet
Microphone
External static pressure 10Pa
H
M
L
36
33
30
Fan tap
Sound pressure
level (dB(A))
70
70
60
60
50
NC-50
40
NC-40
H
M
30
NC-30
L
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
Fan tap
Sound pressure
level (dB(A))
External static pressure 20Pa
20
H
M
L
37
34
31
50
NC-50
40
NC-40
H
M
30
NC-30
L
20
NC-20
NC-20
Approximate threshold of
hearing for continuous noise
Approximate threshold of
hearing for continuous noise
10
10
63
125
250
500
1000
2000
4000
8000
63
125
Octave band center frequency (Hz)
External static pressure 35Pa
H
M
L
39
36
33
Fan tap
Sound pressure
level (dB(A))
70
70
60
60
50
NC-50
40
NC-40
H
M
30
500
1000
2000
4000
8000
External static pressure 50Pa
NC-30
L
20
Octave band sound pressure level (dB)
Octave band soune pressure level (dB)
Fan tap
Sound pressure
level (dB(A))
250
Octave band center frequency (Hz)
H
M
L
41
38
35
50
NC-50
H
M
40
NC-40
L
30
NC-30
20
NC-20
NC-20
Approximate threshold of
hearing for continuous noise
Approximate threshold of
hearing for continuous noise
10
10
63
125
250
500
1000
2000
4000
8000
63
Octave band center frequency (Hz)
125
250
500
1000
2000
Octave band center frequency (Hz)
9-6 -17
4000
8000
2m
MMD-AP0121SPH/SH
Measuring location
Duct
Air outlet
Center
1.5m
Under air intake
Air inlet
Microphone
External static pressure 20Pa
External static pressure 10Pa
Fan tap
Sound pressure
level (dB(A))
H
M
L
38
35
32
Fan tap
Sound pressure
level (dB(A))
70
L
39
36
33
60
50
NC-50
40
NC-40
H
M
30
NC-30
L
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
M
70
60
20
50
NC-50
40
M
30
NC-20
Approximate threshold of
hearing for continuous noise
10
125
250
500
1000
2000
4000
10
8000
63
125
Octave band center frequency (Hz)
M
L
41
38
35
Fan tap
Sound pressure
level (dB(A))
70
60
60
50
NC-50
H
NC-40
M
L
NC-30
20
Octave band sound pressure frequency (dB)
70
30
4000
8000
H
M
L
43
40
37
NC-50
H
40
NC-40
M
L
30
NC-30
NC-20
Approximate threshold of
hearing for continuous noise
10
250
2000
50
Approximate threshold of
hearing for continuous noise
125
1000
20
NC-20
63
500
External static pressure 50Pa
H
40
250
Octave band center frequency (Hz)
External static pressure 35Pa
Fan tap
Sound pressure
level (dB(A))
NC-30
L
20
NC-20
63
NC-40
H
Approximate threshold of
hearing for continuous noise
Octave band sound pressure level (dB)
H
500
1000
2000
4000
10
8000
63
Octave band center frequency (Hz)
125
250
500
1000
2000
Octave band center frequency (Hz)
9-6 -18
4000
8000
MMD-AP0151SPH/SH
2m
Measuring location
Duct
Air outlet
Under air intake
Center
1.5m
Air inlet
Microphone
External static pressure 10Pa
H
M
L
39
36
33
Fan tap
Sound pressure
level (dB(A))
70
70
60
60
50
NC-50
40
NC-40
H
M
30
NC-30
L
Octave band sound frequency level (dB)
Octave band sound pressure level (dB)
Fan tap
Sound pressure
level (dB(A))
External static pressure 20Pa
20
H
M
L
40
37
34
50
NC-50
40
NC-40
H
M
30
NC-30
L
20
NC-20
NC-20
Approximate threshold of
hearing for continuous noise
Approximate threshold of
hearing for continuous noise
10
10
63
125
250
500
1000
2000
4000
8000
63
125
External static pressure 35Pa
H
M
L
41
38
35
Fan tap
Sound pressure
level (dB(A))
70
70
60
60
50
NC-50
H
40
NC-40
M
L
30
500
1000
2000
4000
8000
External static pressure 50Pa
NC-30
20
Octave band sound frequency level (dB)
Octave band sound pressure level (dB)
Fan tap
Sound pressure
level (dB(A))
250
Octave band center frequency (Hz)
Octave band center frequency (Hz)
H
M
L
43
40
37
50
NC-50
H
40
NC-40
M
L
30
NC-30
20
NC-20
NC-20
Approximate threshold of
hearing for continuous noise
Approximate threshold of
hearing for continuous noise
10
10
63
125
250
500
1000
2000
4000
8000
63
Octave band center frequency (Hz)
125
250
500
1000
2000
Octave band center frequency (Hz)
9-6 -19
4000
8000
MMD-AP0181SPH/SH
2m
Measuring location
Duct
Air outlet
Under air intake
Center
1.5m
Air inlet
Microphone
External static pressure 10Pa
H
M
L
40
38
36
Fan tap
Sound pressure
level (dB(A))
70
70
60
60
50
NC-50
40
NC-40
H
M
30
NC-30
L
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
Fan tap
Sound pressure
level (dB(A))
External static pressure 20Pa
H
M
L
42
40
37
50
NC-50
H
40
NC-40
M
L
30
NC-30
20
20
NC-20
NC-20
Approximate threshold of
hearing for continuous noise
Approximate threshold of
hearing for continuous noise
10
10
63
125
250
500
1000
2000
4000
63
8000
125
External static pressure 35Pa
500
1000
2000
4000
8000
External static pressure 50Pa
H
M
L
43
41
38
Fan tap
Sound pressure
level (dB(A))
70
70
60
60
50
NC-50
H
40
NC-40
M
L
30
NC-30
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
Fan tap
Sound pressure
level (dB(A))
250
Octave band center frequency (Hz)
Octave band center frequency (Hz)
20
H
M
L
44
42
39
50
NC-50
H
40
NC-40
M
L
30
NC-30
20
NC-20
NC-20
Approximate threshold of
hearing for continuous noise
Approximate threshold of
hearing for continuous noise
10
10
63
125
250
500
1000
2000
4000
8000
63
Octave band center frequency (Hz)
125
250
500
1000
2000
Octave band center frequency (Hz)
9-6 -20
4000
8000
9-6-7. Accessories
Apperarance
Standard accessories
Qty
Shape
Installation Manual
1
—
Insulating pipe
2
Washer
8
Hose band
1
For connecting drain pipe
Flexible hose
1
For centering the drain pipe
Heat insulator
1
For sealing the wire connection opening
Part name
Use
(Be sure to hand over to customer)
For insulating of pipe connecting section
M10 x Ø34
For hanging down unit
Optional accessories
Remote controller
Model Name
Wired remote controller
RBC-AMT31E
Simple wired remote controller
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E2
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
Central remote controller
TCB-SC642TLE2
ON-OFF controller
TCB-CC163TLE2
9-6 -21
9-7-1. Specifications
50Hz
Specifications (50Hz)
Model name
Cooling/Heating capacity (Note 1)
MMD-
AP0181H
AP0241H
AP0271H
AP0361H
AP0481H
(kW)
5.6/6.3
7.1/8.0
8.0/9.0
11.2/12.5
14.0/16.0
Power supply
(A)
0.81
1.35
1.63
1.84
(kW)
0.184
0.299
0.368
0.414
Power factor
(%)
99
96
Starting current
(A)
1.3
3.5
Running current
Electrical
characteristics
1 phase 50Hz 220V (220-240V) (Separate power supply for indoor units is required.)
Power consumption
Appearance
Outer
dimension
4.1
Height x Width x Depth
(mm)
(kg)
380 x 850 x 660
50
380 x 1,200 x 660
52
Heat exchanger
56
67
1,600
2,100
Finned tube
Soundproof/Heat-insulating material
Non-flammable insulation
Fan
Centrifugal fan
(m3/h)
Standard air flow
Motor
900
1,320
(W)
260
160
External static pressure
(Factory setting)
(Pa)
137
External static pressure
(Pa)
68.6-137-196
Air flow limit
Lower limit/Upper limit
(m3/h)
720/1,080
1,280/1,920
1,060/1,580
Air filter
1,680/2,520
Option or field supply
Controller
Connecting
pipe
4.8
Zinc hot dipping steel plate
Total weight
Fan
unit
98
Remote controller
Gas side
(mm)
O
/ 12.7
O
/ 15.9
Liquid side
(mm)
O
/ 6.4
O
/ 9.5
Drain port
(Nominal dia. mm)
Sound pressure level (Note 2)
(High/Mid/Low)
(dB(A))
25 (One side of male screw)
37
40
PMV Kit
Not available
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in
the actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions
Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
O
O
O
O
O
9-7 -1
O
60Hz
Specifications (60Hz)
Model name
Cooling/Heating capacity (Note 1)
MMD-
AP0181H
AP0241H
AP0271H
AP0361H
AP0481H
(kW)
5.6/6.3
7.1/8.0
8.0/9.0
11.2/12.5
14.0/16.0
Power supply
(A)
0.92
1.80
2.07
2.26
(kW)
0.198
0.385
0.450
0.490
Power factor
(%)
98
97
Starting current
(A)
1.30
3.40
Running current
Electrical
characteristics
1 phase 60Hz 220V (Separate power supply for indoor units is required.)
Power consumption
Appearance
3.90
(mm)
(kg)
Total weight
380 x 850 x 660
50
380 x 1,200 x 660
52
Heat exchanger
56
67
1,600
2,100
Finned tube
Soundproof/Heat-insulating material
Non-flammable insulation
Fan
Centrifugal fan
(m3/h)
Standard air flow
Motor
900
1,320
(W)
260
160
External static pressure
(Factory setting)
(Pa)
137
External static pressure
(Pa)
68.6-137-196
Air flow limit
Lower limit/Upper limit
(m3/h)
720/1,080
1,280/1,920
1,060/1,580
Air filter
1,680/2,520
Option or field supply
Controller
Connecting
pipe
4.35
Zinc hot dipping steel plate
Outer
Height x Width x Depth
dimension
Fan
unit
99
Remote controller
Gas side
(mm)
O
/ 12.7
O
/ 15.9
Liquid side
(mm)
O
/ 6.4
O
/ 9.5
Drain port
(Nominal dia. mm)
Sound pressure level (Note 2)
(High/Mid/Low)
(dB(A))
25 (One side of male screw)
37
40
PMV Kit
Not available
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in
the actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions
Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
O
O
O
9-7 -2
O
O
O
9-7-2. Dimension
MMD-AP0181H, AP0241H, AP0271H, AP0361H, AP0481H
MMD-AP0181H to AP0361H
MMD-AP0481H
710
(Hanging bolt mounting pitch 800)
Hole for hanging bolt
(4-O
/ 12 x 72)
Power supply/
communication
piping port (O
/ 26)
(Under electric parts box)
Electric parts box
Hole for hanging bolt
(4-O
/ 12 x 72)
Power supply/
communication
piping port (O
/ 26)
(Under electric parts box)
Refrigerant pipe connecting port
(Liquid side O
/ A)
Refrigerant pipe connecting port
(Gas side O
/ B)
Electric parts box
Refrigerant pipe connecting port
(Liquid side O
/ 9.5)
Refrigerant pipe connecting port
(Gas side O
/ 15.9)
Screw hole for duct
mounting (6-M6)
Air suction port
Drain pipe connecting port
(VP25)
Screw hole for duct
mounting (8-M6)
Air suction port
Drain pipe connectingport
(VP25)
Z view
Z view
Air discharge port
AP0181H to AP0271H type
Screw hole for duct
mounting (8-M6)
Air discharge port Screw hole for duct
mounting (6-M6)
Air discharge port
AP0361H type
Model MMDAP0181H
AP0241H, AP0271H, AP0361H, AP0481H
A
6.4
9.5
B
12.7
15.9
Service space
Service space
2.7
Check port
600
500 mm or more
Space required for installation and servicing *1
600 mm
or more
4
Wired remote controller
RBC-AMT31E
Wireless remote controller kit
TCB-AX21E2
Simple wired remote controller
RBC-AS21E2
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
120
Screw hole for duct
mounting (4-M6)
Z view
120
16
Note: All dimensions are in mm.
9-7 -3
Indoor unit
Earth screw
Closed
end
connector
WHI
RED
S(N)
F
CN067
(BLK)
RY007
1 2
1 2
4
43F1
3
5
43F1
1 2 3 4
1 2 3 4 GRY
FM
Remote controller
1 2
1 2
CN1
(WHI)
A B
1 2 3
1
3
RC
U1 U2
OC
U1 U2
EMG
1 2
CN044 CN040 CN041
(BRW) (BLU) (BLU)
Outdoor unit
YEL
Closed end
connector
Fuse
T5.0A
CN066
(WHI)
RED
RED 6
Flow selector
unit earth
screw
TR
1
2
1 1
2 2
3 3
RED
RC
L
3 3
2
1 1
F4
F3
F2
X Y
F1
WHI
MCC-1401
DP
LM
CN074
(WHI)
RY001
1 2 3
1 2 3
1 2
1 2
CN075 CN061
(WHI) (YEL)
CN032
(WHI)
CN060
(WHI)
CN082
(BLU)
CN081
(BLK)
TR
1 2 3 4 5 6 CN01
1 2 3 4 5 6 (WHI)
Sub P.C. board
MCC-1520
1 2 3 4 5 6 CN02
1 2 3 4 5 6 (YEL)
6
5
4
3
2
1
Motor over heating protection switch
WHI
GRY
RED
BLK
Wired for MMD-AP0481 only
(BRN Wire)
49F
ORN
BRN
BLU
5
2
1
3
4
6
5
2
1
3
4
6
Parts name
Fan motor
Running capacitor
Transformer
Indoor temp sensor
Temp sensor
Fan motor control relay
Flap motor control relay
Drain control relay
Pulse Motor Valve
Fuse
Fan motor control relay
Drain pump motor
Float switch
PMV
Symbol
FM
RC
TR
TA
TC1,TC2,TCJ
RY005~007
RY001
RY002
PMV
F
43F1
Sold
DM
separately
FS
6
5
4
3
2
1
1
2
3
4
5
1
Filter
2
1 EXCT
2
CN073
(RED)
CN070
(WHI)
1
2 PNL
3
CN080
(GRN)
1 2 3 CN100
1 2 3 (BRN)
TC1
1 2 3 4 5 6 1 2 3 4 5 6 1 2 1 2 3 4 5 6
Option
1 2 3 4 5 6 T10
Fan drive
Power
supply
circuit
1 2
1 2
TC2
CN104 CN102 CN101
(YEL) (RED) (BLK)
1 2
1 2
TCJ
Indoor control P.C. board
FS
CN030
(RED)
1 2 3
1 2 3
TA
1.
indicates the terminal block, the letter inside indicates the terminal number.
2. A dotted line and broken line indicate the wiring on site.
indicates the control P.C. board.
3.
4. When installing a drain pump, Remove CN030 connector and connect float switch.
5 . A part is connected to the terminal block.
When a change is required due to the outside static pressure at site, check the
terminal No. and lead colour of the fan motor in the below diagram and then change
the lead wire as indicated by the arrow mark (
),
6. Pay attention when changing static pressure because the outside static pressure
of H tap in 50 or 60Hz.
Network adaptor
(Option)
1 2 CN03
1 2 (RED)
CN01 1 2
(WHI) 1 2
DP
1 2 3 (BLU) 1 2 3 (GRN)
1 2 3 CN068 1 2 3 CN033
RY002
UL
1 2 3 4 5
CN050
(WHI)
RY005
RY006
M
CN02
(BLU)
H
FAN
9 8 7 6
4
2
CN083(WHI) 9 8 7 6 5 4 3 2 1
7
RY004
P301
43F1
1 1
CN309
2 2 (YEL)
3 3
3
CN304
(GRY) 2
1
(BLK)
T10A,250V~
Power supply
Single phase
220-240V 50Hz
220V 60Hz
R(L)
RED
RED : RED
WHI : WHITE
YEL :YELLOW
BLU : BLUE
BLK : BLACK
GRY : GRAY
PNK : PINK
ORN :ORANGE
BRN : BROWN
GRN : GREEN
8
BLU
WHI
(Option)
ORN
Color
indication
WHI
RED
GRY
WHI
RED
BLK
9-7 -4
BRN
Spark
killer
9-7-3. Wiring diagram
Model: MMD-AP0181H, AP0241H, AP0271H, AP0361H, AP0481H
Symbol
FM
RC
TR
TA
TC1,TC2,TC3
RY005~007
RY001
RY002
PMV
F1~3
43F1,43F2
DM
FS
R(L) S(N)
WHI
Power supply
single phase
220-240V 50Hz
220V 60Hz
Indoor unit
earth screw
RED
WHI
RED
Parts name
Fan motor
Running capacitor
Transformer
Indoor temp sensor
Temp sensor
Fan motor control relay
Louver control relay
Drain control relay
Pulse motor valve
Fuse for fan motor
Fan motor control relay
Drain pump motor
Float switch
RED : RED
WHI : WHITE
YEL :YELLOW
BLU : BLUE
BLK : BLACK
GRY : GRAY
PNK : PINK
ORN :ORANGE
BRN : BROWN
GRN : GREEN
Closed-end
connector
Motor over heating
protection switch
49F
Color
indication
WHI
GRY
RED
BLK
YEL
BLU
ORN
43F2
WHI
RED
7
8
WHI
43F1
8
S.K
WHI
8
AC IN
S.K
F3
F2
1
2
3 3
1 1
F1
WHI
RED
3 3
1 1
3
1
P301
(BLK)
43F1
3
B
FAN3
1 2 3 4 4P
1 2 3 4 (RED)
5
RED
FM3
RC
F1
ORW
F2
F3
X Y
F4
CN03(RED)
1 2
1 2
CN074 1
(WHI) 1
4
6
43F2
MCC-1401
FAN2
1 2 3 4 4P
1 2 3 4 (BLU)
3
3
FM2
F1
ORW
RC
LM
CN033
3 (GRN)
Indicates the terminal bolock,
Letter on the inside indicates the terminal number.
2. A dotted line and broken line indicate
the wiring on site.
3.
indicate the control p.c. board.
4. When fitting a drain pump remove CN030
connector and connect float switch.
1.
Closed-end
connector
3
5
A
RY001
DP
3 CN068
3 (BLU) 1
Network Adapter
(Option)
CN01(WHI)
CN02
(BLU)
1 2
1 2
1 2 3 4 5
3 3
2
1 1
1
1
RY002
UL
1
1
CN050
(WHI)
RY005
L
3
3
RY006
M
H
1 2
1 2
CN1
Remote Controller
RED
43F2
Outdoor unit
U1 U2
T10.0A, 250V~
5
CN041
(BLU)
RY007
5
5
7
7
1 2
1 2 3
1 2 CO 1
3 RC
U1 U2
Line Filter
1 2
EMG
TR
CN044 CN040
(BRW) (BLU)
CN066
(WHI)
CN067
(BLK)
T5.0A 250V~
FUSE
(YEL)
CN309
(GRY)
CN304
RY004
T10.0A, 250V~
T10.0A, 250V~
RED
RED
RED
Sold separately
WHI
FAN
CN083 9
(WHI) 9
BLK
Fan motor inside
wiring diagram
BLU
WHI
RED
GRY
YEL
BLU
WHI
RED
GRY
BLK
Spark Killer
YEL
7
BLU
7
ORN
WHI
RED
GRY
WHI
RED
GRY
6
YEL
RED
3
3
F2
F3
1 2
1 2
TC2
4
6
43F1
FAN1
1 2 3 4 4P
1 2 3 4 (WHI)
CN082
(BLU)
OPTION
FAN
DRIVE
FM1
F1
ORW
RC
F2
F3
F4
Termi- Fan motor
wiring
nal
No.
F1
YEL
F2
BLU
F3
ORN
1 2 3 4 5 6
CN060
(WHI)
6
5
4
3
2
1
5
2
1
3
4
6
5
2
1
3
4
6
PMV
Static
pressure
Pa 69(7)
(mmAg)
137(14)
196(20)
6
5
4
3
2
1
1
FILTER
2
1
2
3
4
5
1 2
CN032
(WHI)
Setting from
factory
Note
board
unit
MCC-1403
Control P.C.
1
EXCT for Indoor
2
1
2 PNL
3
CN081
(BLK)
CN070
(WHI)
CN073
(RED)
CN100
(BRW) CN080
(GRN)
1
3
1 2 3
TC1
5. A Position is connected to the terminal block when there is a
change to static pressure. change the lead wire of arrow
position after checking the terminal number as per figure
and the lead wire's checking fan motor.
6. When setting to the high tap, take care as the static pressures
are different at50Hz and 60Hz.
F4
1 2 3 4 5 6 CN01
1 2 3 4 5 6 (YEL)
TR
CN061
(YEL)
1 2 3 4 5 6
1 2 3 4 5 6 CN02
1 2 3 4 5 6 (YEL)
Sub P.C. board
MCC-1520
1 2
1 2
TCJ
CN104 CN102 CN101
(YEL) (RED) (BLK)
1 2
1 2
TA
Control P.C. board
for Indoor unit
MCC-1403
CN030
(RED)
FS
1
1
CN075
(WHI)
1 2 3 4 5 6
1 2 3 4 5 6
Power supply
circuit
BLU
DM
ORN
WHI
RED
GRY
WHI
RED
GRY
(Option)
YEL
RED
BLU
9-7 -5
ORN
RED
Model: MMD-AP0721H, AP0961H
9-7-4. Sensible capacity table
(MMD-AP***H)
Cooling capacity
Unit
size
018
024
027
Outdoor
air temp.
°CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
16.0°CWB
23°CDB
TC
SHC
5.1
3.8
5.1
3.8
5.1
3.8
5.1
3.8
5.1
3.8
5.1
3.8
5.1
3.8
5.1
3.8
5.1
3.8
5.1
3.8
5.1
3.8
5.1
3.8
5.1
3.8
5.1
3.8
5.0
3.7
4.9
3.6
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.4
4.7
6.3
4.6
6.2
4.4
7.3
5.1
7.3
5.1
7.3
5.1
7.3
5.1
7.3
5.1
7.3
5.1
7.3
5.1
7.3
5.1
7.3
5.1
7.3
5.1
7.3
5.1
7.3
5.1
7.3
5.1
7.3
5.1
7.1
5.0
7.0
4.8
18.0°CWB
26°CDB
TC
SHC
5.4
4.0
5.4
4.0
5.4
4.0
5.4
4.0
5.4
4.0
5.4
4.0
5.4
4.0
5.4
4.0
5.4
4.0
5.4
4.0
5.4
4.0
5.4
4.0
5.4
4.0
5.4
4.0
5.3
3.9
5.2
3.8
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.9
5.0
6.7
4.9
6.6
4.7
7.8
5.4
7.8
5.4
7.8
5.4
7.8
5.4
7.8
5.4
7.8
5.4
7.8
5.4
7.8
5.4
7.8
5.4
7.8
5.4
7.8
5.4
7.8
5.4
7.8
5.4
7.8
5.4
7.6
5.3
7.4
5.1
TC : Total Capacity (kW) SHC : Sensible Heat Capacity (kW)
Indoor air temp.
19.0°CWB
20.0°CWB
22.0°CWB
24.0°CWB
27°CDB
28°CDB
30°CDB
32°CDB
TC
SHC
TC
SHC
TC
SHC
TC
SHC
5.6
4.0
5.8
4.0
6.1
4.0
6.4
3.9
5.6
4.0
5.8
4.0
6.1
4.0
6.4
3.9
5.6
4.0
5.8
4.0
6.1
4.0
6.4
3.9
5.6
4.0
5.8
4.0
6.1
4.0
6.4
3.9
5.6
4.0
5.8
4.0
6.1
4.0
6.4
3.9
5.6
4.0
5.8
4.0
6.1
4.0
6.4
3.9
5.6
4.0
5.8
4.0
6.1
4.0
6.4
3.9
5.6
4.0
5.8
4.0
6.1
4.0
6.4
3.9
5.6
4.0
5.8
4.0
6.1
4.0
6.4
3.9
5.6
4.0
5.8
4.0
6.1
4.0
6.4
3.9
5.6
4.0
5.8
4.0
6.1
4.0
6.4
3.9
5.6
4.0
5.8
4.0
6.1
4.0
6.4
3.9
5.6
4.0
5.8
4.0
6.1
4.0
6.4
3.9
5.6
4.0
5.8
4.0
6.1
4.0
6.4
3.9
5.5
3.9
5.7
3.9
6.0
3.9
6.3
3.8
5.4
3.8
5.5
3.8
5.9
3.7
6.1
3.6
7.1
5.0
7.3
5.0
7.7
5.0
8.1
4.8
7.1
5.0
7.3
5.0
7.7
5.0
8.1
4.8
7.1
5.0
7.3
5.0
7.7
5.0
8.1
4.8
7.1
5.0
7.3
5.0
7.7
5.0
8.1
4.8
7.1
5.0
7.3
5.0
7.7
5.0
8.1
4.8
7.1
5.0
7.3
5.0
7.7
5.0
8.1
4.8
7.1
5.0
7.3
5.0
7.7
5.0
8.1
4.8
7.1
5.0
7.3
5.0
7.7
5.0
8.1
4.8
7.1
5.0
7.3
5.0
7.7
5.0
8.1
4.8
7.1
5.0
7.3
5.0
7.7
5.0
8.1
4.8
7.1
5.0
7.3
5.0
7.7
5.0
8.1
4.8
7.1
5.0
7.3
5.0
7.7
5.0
8.1
4.8
7.1
5.0
7.3
5.0
7.7
5.0
8.1
4.8
7.1
5.0
7.3
5.0
7.7
5.0
8.1
4.8
7.0
4.9
7.2
4.9
7.6
4.9
7.9
4.7
6.8
4.7
7.0
4.7
7.4
4.7
7.8
4.6
8.0
5.4
8.2
5.4
8.7
5.3
9.1
5.2
8.0
5.4
8.2
5.4
8.7
5.3
9.1
5.2
8.0
5.4
8.2
5.4
8.7
5.3
9.1
5.2
8.0
5.4
8.2
5.4
8.7
5.3
9.1
5.2
8.0
5.4
8.2
5.4
8.7
5.3
9.1
5.2
8.0
5.4
8.2
5.4
8.7
5.3
9.1
5.2
8.0
5.4
8.2
5.4
8.7
5.3
9.1
5.2
8.0
5.4
8.2
5.4
8.7
5.3
9.1
5.2
8.0
5.4
8.2
5.4
8.7
5.3
9.1
5.2
8.0
5.4
8.2
5.4
8.7
5.3
9.1
5.2
8.0
5.4
8.2
5.4
8.7
5.3
9.1
5.2
8.0
5.4
8.2
5.4
8.7
5.3
9.1
5.2
8.0
5.4
8.2
5.4
8.7
5.3
9.1
5.2
8.0
5.4
8.2
5.4
8.7
5.3
9.1
5.2
7.8
5.3
8.1
5.3
8.5
5.2
8.9
5.1
7.7
5.1
7.9
5.1
8.4
5.0
8.8
4.9
9-7 -6
Cooling capacity (cont.)
Unit
size
036
048
Outdoor
air temp.
°CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
16.0°CWB
23°CDB
TC
SHC
10.2
7.4
10.2
7.4
10.2
7.4
10.2
7.4
10.2
7.4
10.2
7.4
10.2
7.4
10.2
7.4
10.2
7.4
10.2
7.4
10.2
7.4
10.2
7.4
10.2
7.4
10.2
7.4
10.0
7.2
9.8
6.9
12.7
9.0
12.7
9.0
12.7
9.0
12.7
9.0
12.7
9.0
12.7
9.0
12.7
9.0
12.7
9.0
12.7
9.0
12.7
9.0
12.7
9.0
12.7
9.0
12.7
9.0
12.7
9.0
12.5
8.8
12.2
8.4
18.0°CWB
26°CDB
TC
SHC
10.9
7.8
10.9
7.8
10.9
7.8
10.9
7.8
10.9
7.8
10.9
7.8
10.9
7.8
10.9
7.8
10.9
7.8
10.9
7.8
10.9
7.8
10.9
7.8
10.9
7.8
10.9
7.8
10.6
7.7
10.4
7.4
13.6
9.5
13.6
9.5
13.6
9.5
13.6
9.5
13.6
9.5
13.6
9.5
13.6
9.5
13.6
9.5
13.6
9.5
13.6
9.5
13.6
9.5
13.6
9.5
13.6
9.5
13.6
9.5
13.3
9.3
13.0
9.0
Indoor air temp.
19.0°CWB
27°CDB
TC
SHC
11.2
7.8
11.2
7.8
11.2
7.8
11.2
7.8
11.2
7.8
11.2
7.8
11.2
7.8
11.2
7.8
11.2
7.8
11.2
7.8
11.2
7.8
11.2
7.8
11.2
7.8
11.2
7.8
11.0
7.6
10.8
7.3
14.0
9.5
14.0
9.5
14.0
9.5
14.0
9.5
14.0
9.5
14.0
9.5
14.0
9.5
14.0
9.5
14.0
9.5
14.0
9.5
14.0
9.5
14.0
9.5
14.0
9.5
14.0
9.5
13.7
9.3
13.4
8.9
20.0°CWB
28°CDB
TC
SHC
11.5
7.8
11.5
7.8
11.5
7.8
11.5
7.8
11.5
7.8
11.5
7.8
11.5
7.8
11.5
7.8
11.5
7.8
11.5
7.8
11.5
7.8
11.5
7.8
11.5
7.8
11.5
7.8
11.3
7.6
11.1
7.3
14.4
9.5
14.4
9.5
14.4
9.5
14.4
9.5
14.4
9.5
14.4
9.5
14.4
9.5
14.4
9.5
14.4
9.5
14.4
9.5
14.4
9.5
14.4
9.5
14.4
9.5
14.4
9.5
14.1
9.3
13.8
8.9
9-7 -7
22.0°CWB
30°CDB
TC
SHC
12.2
7.7
12.2
7.7
12.2
7.7
12.2
7.7
12.2
7.7
12.2
7.7
12.2
7.7
12.2
7.7
12.2
7.7
12.2
7.7
12.2
7.7
12.2
7.7
12.2
7.7
12.2
7.7
12.0
7.6
11.7
7.3
15.3
9.4
15.3
9.4
15.3
9.4
15.3
9.4
15.3
9.4
15.3
9.4
15.3
9.4
15.3
9.4
15.3
9.4
15.3
9.4
15.3
9.4
15.3
9.4
15.3
9.4
15.3
9.4
15.0
9.2
14.6
8.9
24.0°CWB
32°CDB
TC
SHC
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.8
7.5
12.5
7.4
12.3
7.1
16.0
9.2
16.0
9.2
16.0
9.2
16.0
9.2
16.0
9.2
16.0
9.2
16.0
9.2
16.0
9.2
16.0
9.2
16.0
9.2
16.0
9.2
16.0
9.2
16.0
9.2
16.0
9.2
15.6
9.0
15.3
8.6
Heating capacity
Unit
size
018
024
027
Outdoor
air temp.
°CWB
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
SHC
3.9
4.2
4.5
4.6
4.9
5.1
5.4
5.6
5.9
6.1
6.3
6.6
6.6
6.6
6.6
6.6
5.0
5.3
5.7
5.8
6.2
6.5
6.8
7.1
7.4
7.7
8.0
8.3
8.3
8.3
8.3
8.3
5.6
6.0
6.4
6.6
7.0
7.3
7.7
8.0
8.4
8.7
9.0
9.4
9.4
9.4
9.4
9.4
SHC : Sensible Heat Capacity (kW)
Indoor air temp. °CDB
18.0
20.0
22.0
24.0
SHC
SHC
SHC
SHC
3.9
3.8
3.7
3.6
4.1
4.0
3.9
3.8
4.4
4.3
4.2
4.1
4.5
4.4
4.3
4.2
4.8
4.7
4.6
4.4
5.0
4.9
4.8
4.7
5.3
5.2
5.0
4.9
5.5
5.4
5.3
5.1
5.8
5.6
5.5
5.3
6.0
5.9
5.7
5.6
6.2
6.1
5.9
5.8
6.4
6.3
6.1
6.0
6.4
6.3
6.1
6.0
6.4
6.3
6.1
6.0
6.4
6.3
6.1
6.0
6.4
6.3
6.1
6.0
4.9
4.8
4.7
4.6
5.2
5.1
5.0
4.9
5.6
5.5
5.3
5.2
5.7
5.6
5.5
5.3
6.1
5.9
5.8
5.6
6.4
6.2
6.1
5.9
6.7
6.6
6.4
6.2
7.0
6.9
6.7
6.5
7.3
7.1
7.0
6.8
7.6
7.4
7.3
7.1
7.9
7.7
7.5
7.3
8.2
8.0
7.8
7.6
8.2
8.0
7.8
7.6
8.2
8.0
7.8
7.6
8.2
8.0
7.8
7.6
8.2
8.0
7.8
7.6
5.5
5.4
5.3
5.1
5.9
5.8
5.6
5.5
6.3
6.1
6.0
5.8
6.5
6.3
6.2
6.0
6.8
6.7
6.5
6.3
7.2
7.0
6.9
6.7
7.5
7.4
7.2
7.0
7.9
7.7
7.5
7.3
8.2
8.0
7.8
7.6
8.5
8.4
8.2
7.9
8.9
8.7
8.5
8.3
9.2
9.0
8.8
8.6
9.2
9.0
8.8
8.6
9.2
9.0
8.8
8.6
9.2
9.0
8.8
8.6
9.2
9.0
8.8
8.6
9-7 -8
Heating capacity (cont.)
Unit
size
036
048
Outdoor
air temp.
°CWB
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
SHC
7.8
8.3
8.9
9.1
9.7
10.2
10.7
11.1
11.6
12.1
12.6
13.0
13.0
13.0
13.0
13.0
10.0
10.7
11.4
11.7
12.4
13.0
13.6
14.3
14.9
15.5
16.1
16.7
16.7
16.7
16.7
16.7
Indoor air temp. °CDB
18.0
20.0
22.0
SHC
SHC
SHC
7.7
7.5
7.3
8.2
8.0
7.8
8.7
8.5
8.3
9.0
8.8
8.6
9.5
9.3
9.1
10.0
9.8
9.5
10.5
10.2
10.0
10.9
10.7
10.5
11.4
11.2
10.9
11.9
11.6
11.3
12.3
12.1
11.8
12.8
12.5
12.2
12.8
12.5
12.2
12.8
12.5
12.2
12.8
12.5
12.2
12.8
12.5
12.2
9.8
9.6
9.4
10.5
10.3
10.0
11.1
10.9
10.7
11.5
11.2
11.0
12.1
11.9
11.6
12.8
12.5
12.2
13.4
13.1
12.8
14.0
13.7
13.4
14.6
14.3
14.0
15.2
14.9
14.5
15.8
15.4
15.1
16.3
16.0
15.6
16.3
16.0
15.6
16.3
16.0
15.6
16.3
16.0
15.6
16.3
16.0
15.6
24.0
SHC
7.2
7.6
8.1
8.3
8.8
9.3
9.7
10.2
10.6
11.0
11.5
11.9
11.9
11.9
11.9
11.9
9.1
9.7
10.4
10.7
11.3
11.9
12.4
13.0
13.6
14.1
14.7
15.2
15.2
15.2
15.2
15.2
9-7 -9
9-7-5. Fan characteristics
MMD-AP0241H, AP0271H
Standard air volume: 900 m3/h
1.5
Fan motor current (A)
Fan motor current (A)
MMD-AP0181H
High static pressure tap
Medium static pressure tap
1.0
0.5
Low static pressure tap
Standard air volume: 1,320 m3/h
2.0
High static pressure tap
Medium static pressure tap
1.5
Low static pressure tap
1.0
300
250
st
at
ic
pr
es
su
re
ta
p
at
ic
pr
es
s
M
ed
ur
iu
m
st
at
ic
e
ta
p
pr
es
su
100
re
ta
p
re
su
es
pr
ta
50
50
700
800
900
1,000
p
0
150
st
ic
ta
p
200
at
pr
es
su
re
tap
Air volume upper limit
Lo
w
st
at
ic
ure
Hi
gh
st
100
ss
M
ed
iu
m
Air volume lower limit
150
pre
Air volume upper limit
tic
Outside static pressure (Pa)
sta
200
50Hz
60Hz
w
Lo
Outside static pressure (Pa)
gh
250
Air volume lower limit
50Hz
60Hz
Hi
0
1,000
1,100
1,100
1,200
1,320
1,300
1,400
1,500
1,600
Air volume (m³/h)
Air volume (m³/h)
MMD-AP0361H
MMD-AP0481H
Standard air volume: 2,100 m3/h
3
Standard air volume: 1,600 m /h
3.0
Fan motor current (A)
Fan motor current (A)
2.5
High static pressure tap
2.0
Medium static pressure tap
1.5
Low static pressure tap
High static pressure tap
2.5
2.0
Medium static pressure tap
1.5
1.0
Low static pressure tap
150
100
Me
diu
m
sta
tic
pre
ssu
re t
pre
ssu
re
Lo
ws
tat
tap
ic p
res
su
re
50
0
ap
250
200
150
100
tap
50
1,400
1,500
1,600
1,700
0
1,800
50Hz
Hig
hs
60Hz
tat
ic
pre
ss
ure
M
tap
ed
ium
sta
tic
pr
es
su
re
Lo
ta
p
w
st
at
ic
pr
es
su
re
ta
p
2,100
1,500
2,000
Air volume (m³/h)
Air volume (m³/h)
9-7 -10
Air volume upper limit
atic
200
Air volume lower limit
Outside static pressure (Pa)
h st
Air volume lower limit
50Hz
60Hz
Hig
Outside static pressure (Pa)
250
Air volume upper limit
0.5
2,500
9-7-6. Sound characteristics (NC-Curve)
Sound level values shown are based on a measurement in a non resound room.
Microphone
(dB)
(dB)
Outside still pressure 68.6 (Pa) 137.2 (Pa) 196.0 (Pa)
Outside still pressure 68.6 (Pa) 137.2 (Pa) 196.0 (Pa)
Overall level A
(dB)
C
33
37
40
46
51
53
Overall level A
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
MMD-AP0181H
(standard sound pressure 0.0002 µbar)
196.0(external static pressure(Pa))
Audibility limits
of continuous
white level
(dB)
37
40
47
49
53
196.0(external static pressure(Pa))
Audibility limits
of continuous
white level
Octave band center frequency (Hz)
(dB)
(dB)
Outside still pressure 68.6 (Pa) 137.2 (Pa) 196.0 (Pa)
Outside still pressure 68.6 (Pa) 137.2 (Pa) 196.0 (Pa)
Overall level A
(dB)
C
36
40
44
50
53
57
(standard sound pressure 0.0002 µbar)
196.0(external static pressure(Pa))
Audibility limits
of continuous
white level
Octave band center frequency (Hz)
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
33
(standard sound pressure 0.0002 µbar)
Octave band center frequency (Hz)
MMD-AP0241H, AP0271H
C
Overall level A
(dB)
C
36
40
44
50.5
53
57
(standard sound pressure 0.0002 µbar)
9-7 -11
196.0(external static pressure(Pa))
Audibility limits
of continuous
white level
Octave band center frequency (Hz)
MMD-AP0361H
(dB)
(dB)
Octave band sound pressure level (dB)
Overall level A
(dB)
C
68.6 (Pa)
137.2 (Pa) 196.0 (Pa)
36
40
44
49.5
54
59
Octave band sound pressure level (dB)
Outside still pressure
(standard sound pressure 0.0002 µbar)
196.0(external static pressure(Pa))
Audibility limits
of continuous
white level
Octave band center frequency (Hz)
Outside still pressure
68.6 (Pa)
Overall level A
36
40
44
49
53.5
57
(dB)
C
137.2 (Pa) 196.0 (Pa)
(standard sound pressure 0.0002 µbar)
196.0(external static pressure(Pa))
Audibility limits
of continuous
white level
Octave band center frequency (Hz)
(dB)
68.6 (Pa)
Overall level A
36
40
44
47
51
54
(dB)
C
137.2 (Pa) 196.0 (Pa)
(standard sound pressure 0.0002 µbar)
196.0(external static pressure(Pa))
Audibility limits
of continuous
white level
Octave band center frequency (Hz)
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
(dB)
Outside still pressure
9-7 -12
Outside still pressure
68.6 (Pa)
Overall level A
36
40
44
47
51
54
(dB)
C
137.2 (Pa) 196.0 (Pa)
(standard sound pressure 0.0002 µbar)
196.0(external static pressure(Pa))
Audibility limits
of continuous
white level
Octave band center frequency (Hz)
Sound level data (NC CURVE)
Sound level values shown are based on a measurement in a non resound room.
MMD-AP0721H
(50Hz)
Overall level A
Octave band sound pressure level (dB)
(dB)
C
69 (Pa)
137 (Pa)
196 (Pa)
48
49
50.5
54
55
57
(60Hz)
Outside still pressure
Overall level A
(dB)
Octave band sound pressure level (dB)
Outside still pressure
Audibility limits
of continuous
white level
C
69 (Pa)
137 (Pa)
196 (Pa)
48
49
50.5
55
50
58
Audibility limits
of continuous
white level
Octave band center frequency (Hz)
Octave band center frequency (Hz)
MMD-AP0961H
(50Hz)
Overall level A
Octave band sound pressure level (dB)
(dB)
C
69 (Pa)
137 (Pa)
196 (Pa)
49
50
51.5
56
59
61
Audibility limits
of continuous
white level
(60Hz)
Outside still pressure
Overall level A
(dB)
Octave band sound pressure level (dB)
Outside still pressure
Octave band center frequency (Hz)
C
69 (Pa)
137 (Pa)
196 (Pa)
49
50
51.5
57
59
61
Audibility limits
of continuous
white level
Octave band center frequency (Hz)
9-7 -13
9-7-7. Accessories
Apperarance
Standard accessories
Part name
Qty
Installation
Manual
1
Insulation
1
Shape
Use
Part name
Qty
Insulation
1
For insulating the gas pipe
connection
Remote controller
Model Name
Wired remote controller
RBC-AMT31E
Simple wired remote controller
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E2
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
Central remote controller
TCB-SC642TLE2
ON-OFF controller
TCB-CC163TLE2
9-7 -14
Shape
Use
For insulating the liquid pipe
connection
Optional accessories
Filter Chamber
TCB-FCY21DE, TCB-FCY31DE
TCB-FCY51DE
Long Life Pre-Filter
TCB-PF1D-1E
TCB-PF2D-1E
High Efficiency Filter 65
TCB-UFM1D-1E, TCB-UFM2D-1E
Drain pump kit
TCB-DP31DE
Name
High Efficiency Filter 65
High Efficiency Filter 90
Long life Pre-filter
High Efficiency Filter 90
TCB-UFH5D-1E, TCB-UFH6D-1E
Model name
TCB-UFM1D-1E
Dust collecting effect :65%
(NBS Colorimentric method)
Use with TCB-FCY21D
TCB-UFM2D-1E(2 pcs.)
Dust collecting effect :65%
(NBS Colorimentric method)
Use with TCB-FCY31D
TCB-UFM1D-1E(2 pcs.)
Dust collecting effect :65%
(NBS Colorimentric method)
Use with TCB-FCY41D
TCB-UFH5D-1E
Dust collecting effect :90%
(NBS Colorimentric method)
Use with TCB-FCY21D
TCB-UFH6D-1E (2 pcs.)
Dust collecting effect :90%
(NBS Colorimentric method)
Use with TCB-FCY31D
TCB-UFH5D-1E (2 pcs.)
Dust collecting effect :90%
(NBS Colorimentric method)
Use with TCB-FCY41D
TCB-PF1D-1E
Dust collecting effect :50%
(Weight method)
Use with TCB-FCY21D
TCB-PF2D-1E (2 pcs.)
Dust collecting effect :50%
(Weight method)
Use with TCB-FCY31D
TCB-PF1D-1E (2 pcs.)
Dust collecting effect :50%
(Weight method)
Use with TCB-FCY41D
TCB-FCY21DE
Filter Chamber
Note
TCB-FCY31DE
For high efficiency filter
or long life pre-filter
TCB-FCY51DE
Drain Pump Kit
TCB-DP31DE
Stand-up 330 or less
(from bottom face of ceiling)
9-7 -15
9-8-1. Specifications
50Hz
Specifications (50Hz)
Model name
MMC-
AP0151H
AP0181H
AP0241H
AP0271H
AP0361H
AP0481H
(kW)
4.5/5.0
5.6/6.3
7.1/8.0
8.0/9.0
11.2/12.5
14.0/16.0
Cooling/Heating capacity (Note 1)
1 phase 50Hz 230V (220-240V) (Separate power supply for indoor units is required.)
Power supply
Electrical
characteristics
Running current
(A)
Power consumption
(kW)
Appearance Starting current
Outer
dimension
0.29
0.32
0.42
0.78
0.84
0.033
0.038
0.050
0.091
0.110
0.43
0.48
0.62
1.17
1.25
(A)
Height x Width x Depth
Total weight
White (Munsell 10Y 9.3/0.4)
(mm)
210 x 910 x 680
210 x 1,180 x 680
210 x 1,595 x 680
(kg)
22
26
34
Finned tube
Heat exchanger
Non-flammable insulation
Soundproof/Heat-insulating material
Centrifugal fan
Fan
Fan unit
Standard air flow
(High/Mid/Low)
Motor
(m3/h)
780/660/540
720/600/540
30
(W)
1,800/1,560/
1,320
1,650/1,380/
1,200
1,110/900/840
40
80
Remote controller
Controller
Standard filter (Long life filter)
Air filter
Gas side
Connecting
Liquid side
pipe
Drain port
(mm)
O
/ 12.7
O
/ 15.9
(mm)
O
/ 6.4
O
/ 9.5
20 (Polyvinyl chloride tube)
(Nominal dia. mm)
Sound pressure level (Note 2)
(High/Mid/Low)
(dB(A))
35/32/30
36/33/30
PMV Kit
38/36/33
41/38/35
43/40/37
Not available
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the
actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB
Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB/6oC WB
9-8 -1
60Hz
Specifications (60Hz)
Model name
Cooling/Heating capacity (Note 1)
MMC-
AP0151H
AP0181H
AP0241H
AP0271H
AP0361H
AP0481H
(kW)
4.5/5.0
5.6/6.3
7.1/8.0
8.0/9.0
11.2/12.5
14.0/16.0
1 phase 60Hz 220V (Separate power supply for indoor units is required.)
Power supply
Running current
Electrical
characteristics
(A)
0.30
0.34
0.44
0.82
0.87
Power consumption (kW)
0.033
0.038
0.050
0.091
0.110
Starting current
0.43
0.48
0.62
1.17
1.25
(A)
White (Munsell 10Y 9.3/0.4)
Appearance
Outer
Height x Width x Depth
dimension
Total weight
(mm)
210 x 910 x 680
210 x 1,180 x 680
210 x 1,595 x 680
(kg)
22
26
34
Finned tube
Heat exchanger
Soundproof/Heat-insulating material
Non-flammable insulation
Fan
Centrifugal fan
Fan unit
Standard air flow
(High/Mid/Low)
Motor
(m3/h)
720/600/540
(W)
780/660/540
30
1,650/1,380/1,200 1,800/1,560/1,320
40
80
Remote controller
Controller
Air filter
Connecting
pipe
1,110/900/840
Standard filter (Long life filter)
Gas side
(mm)
O
/ 12.7
O
/ 15.9
Liquid side
(mm)
O
/ 6.4
O
/ 9.5
Drain port (Nominal dia. mm)
Sound pressure level (Note 2)
(High/Mid/Low)
(db(A))
20 (Polyvinyl chloride tube)
35/32/30
36/33/30
38/36/33
41/38/35
43/40/37
Not available
PMV Kit
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in
the actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions
Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
O
O
O
9-8 -2
O
O
O
9-8-2. Dimension
MMC-AP0151H, AP0181H, AP0241H, AP0271H, AP0361H, AP0481H
Upper piping drawing-out port (Knockout hole)
Piping drawing-out port
(Knockout port)
70
(Hanging position)
Drain port VP20
(Inner diam. O
/ 26, hose supplied)
Left drain size
Drain pipe
connecting port
B (Hanging position)
Refrigerant pipe (Liquid side O
/ D)
Refrigerant pipe (Gas side O
/ C)
Model MMC-
A
A
B
C
D
AP0151H, AP0181H
910
855
12.7
6.4
AP0241H, AP0271H
1180
1125
15.9
9.5
AP0361H, AP0481H
1595
1540
15.9
9.5
Wireless sensor
mounting section
(Optional)
Ceiling surface
Unit
250 or more
250 or more
(Front side to be positioned horizontally.)
500
or more
Within 50
Hanging bolt
Space required for installation and servicing
Remote controller cable taking-in port
Power supply taking-in port
(Knockout hole)
Remote controller cable taking-in port
(Knockout hole)
2.7
4
Wired remote controller
RBC-AMT31E
Simple wired remote controller
RBC-AS21E2
120
320 170
Power supply cable taking-in port
(Knockout)
Remote controller piping
taking-in port (Knockout hole)
Wireless remote controller kit
TCB-AX22CE2
120
16
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
Air taking-in port
(Duct sold separately) (Knockout hole O
/ 92)
Drain left piping drawing-out port
Piping hole on the wall
(Knockout hole)
(O
/ 100 hole)
Note: All dimensions are in mm.
9-8 -3
RED
Flow selector
unit earth
screw
DM
9-8 -4
3
CN304 1
(GRY) 2
1 1
2 2
3 3
CN68
(BLU)
CN41
(BLU)
CN40
(BLU)
CN66
(WHI)
Fuse
T6.3A
250V~
P301
RY303
RY302
BLK
Ð
Adpter for wireless
remote controller
CN001
(WHI)
BLK
WHI
BLK
3 3
2 2
1 1
Option
1 2 3 4 5 6
CN60
(WHI)
DC20V
DC15V
DC12V
DC7V
indicates the terminal number.
indicates the terminal block, the letter inside
X Y
1 2 CN03
1 2 (RED)
Network
adaptor
P.C. board
Network
CN01 1 2 adaptor
(WHI) 1 2 (Option)
CN02
(BLU)
TR
1 2
Fandrive
T10
CN32
(WHI)
Power
supply
circuit
3.
indicates the control P.C. board.
CN81
(BLK)
Sold
separately
1 2 3 4 5
2 . A dotted line and broken line indicate the wiring on site.
1.
1 2 3 4 5
CN61
(YEL)
Fuse
T3.15A
Indoor control P.C. board
CN70
(WHI)
CN73
(RED)
CN80
(GRN)
CN100
(BRW)
TA
1 FILTER
2
RED
WHI
YEL
BLU
BRN
BLK
GRY
PNK
ORN
GRN
: BLACK
: GRAY
: PINK
: ORANGE
: GREEN
Parts name
Fan motor
Indoor temp sensor
Temp sensor
Louver motor
Drain control relay
Drain pump motor
Float switch
: RED
: WHITE
: YELLOW
: BLUE
: BROWN
TC1
TC2
TCJ
1 EXCT
2
1
2 PNL
3
1 1
2 2
3 3
1 1
2 2
1 1
2 2
CN102
(RED)
CN101
(BLK)
1 1
2 2
CN104
(YEL)
Color identification
GRL
FS
1
3 CN34
1 2 3 (RED)
1 2 3 4 5
CN20
(BLU)
Symbol
FM
TA
TC1,TC2,TCJ
LM
RY302
DM
FS
1 2 3 4 5 CN33
1 2 3 4 5 (WHI)
1 2 3 4 5 6 CN82
1 2 3 4 5 6 (BLU)
LM
1 2 3 4 5
1 2 3 4 5
6 4 3 1 2 5
6 4 3 1 2 5
1 2 3 4 5 6
Motor drive
circuit
+
CN50
(WHI)
Wired remote
controller
WHI
1 2 3
1 2 3
CN309
(YEL)
~
~
1 2
1 2
CN1
(WHI)
FM
5 4
1 CN334 1 2 3 4 5 CN333
5 4 3 2 1 (WHI) 1 2 3 4 5 (WHI)
1 2
1 2
WHI
U1 U2 A B
1 1
2
BLK
3 3
BLK
2 2
BLU
1 1
BLU
1
2
BLK
1 1
CN67
(BLK) 2 2
3 3
Outdoor unit
U1 U2
Closed end
terminal
RED
WHI
Power supply
single phase
200-240V 50Hz
200V 60Hz
R(L) S(N)
Earth screw
Indoor unit
WHI
PMV
9-8-3. Wiring diagram
Model: MMC-AP0151H, AP0181H, AP0241H, AP0271H, AP0361H, AP0481H
9-8-4. Sensible capacity table
(MMD-AP***H)
Cooling capacity
Unit
size
015
018
024
Outdoor
air temp.
°CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
16.0°CWB
23°CDB
TC
SHC
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.1
3.0
4.0
3.0
3.9
2.8
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.1
3.7
5.0
3.6
4.9
3.5
6.4
4.8
6.4
4.8
6.4
4.8
6.4
4.8
6.4
4.8
6.4
4.8
6.4
4.8
6.4
4.8
6.4
4.8
6.4
4.8
6.4
4.8
6.4
4.8
6.4
4.8
6.4
4.8
6.3
4.7
6.2
4.5
18.0°CWB
26°CDB
TC
SHC
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.4
3.2
4.3
3.1
4.2
3.0
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.4
3.9
5.3
3.8
5.2
3.7
6.9
5.1
6.9
5.1
6.9
5.1
6.9
5.1
6.9
5.1
6.9
5.1
6.9
5.1
6.9
5.1
6.9
5.1
6.9
5.1
6.9
5.1
6.9
5.1
6.9
5.1
6.9
5.1
6.7
5.0
6.6
4.8
TC : Total Capacity (kW) SHC : Sensible Heat Capacity (kW)
Indoor air temp.
19.0°CWB
20.0°CWB
22.0°CWB
24.0°CWB
27°CDB
28°CDB
30°CDB
32°CDB
TC
SHC
TC
SHC
TC
SHC
TC
SHC
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.5
3.2
4.6
3.2
4.9
3.2
5.1
3.1
4.4
3.1
4.5
3.1
4.8
3.1
5.0
3.0
4.3
3.0
4.4
3.0
4.7
3.0
4.9
2.9
5.6
3.9
5.8
3.9
6.1
3.9
6.4
3.8
5.6
3.9
5.8
3.9
6.1
3.9
6.4
3.8
5.6
3.9
5.8
3.9
6.1
3.9
6.4
3.8
5.6
3.9
5.8
3.9
6.1
3.9
6.4
3.8
5.6
3.9
5.8
3.9
6.1
3.9
6.4
3.8
5.6
3.9
5.8
3.9
6.1
3.9
6.4
3.8
5.6
3.9
5.8
3.9
6.1
3.9
6.4
3.8
5.6
3.9
5.8
3.9
6.1
3.9
6.4
3.8
5.6
3.9
5.8
3.9
6.1
3.9
6.4
3.8
5.6
3.9
5.8
3.9
6.1
3.9
6.4
3.8
5.6
3.9
5.8
3.9
6.1
3.9
6.4
3.8
5.6
3.9
5.8
3.9
6.1
3.9
6.4
3.8
5.6
3.9
5.8
3.9
6.1
3.9
6.4
3.8
5.6
3.9
5.8
3.9
6.1
3.9
6.4
3.8
5.5
3.8
5.7
3.8
6.0
3.8
6.3
3.7
5.4
3.7
5.5
3.7
5.9
3.6
6.1
3.6
7.1
5.1
7.3
5.1
7.7
5.1
8.1
4.9
7.1
5.1
7.3
5.1
7.7
5.1
8.1
4.9
7.1
5.1
7.3
5.1
7.7
5.1
8.1
4.9
7.1
5.1
7.3
5.1
7.7
5.1
8.1
4.9
7.1
5.1
7.3
5.1
7.7
5.1
8.1
4.9
7.1
5.1
7.3
5.1
7.7
5.1
8.1
4.9
7.1
5.1
7.3
5.1
7.7
5.1
8.1
4.9
7.1
5.1
7.3
5.1
7.7
5.1
8.1
4.9
7.1
5.1
7.3
5.1
7.7
5.1
8.1
4.9
7.1
5.1
7.3
5.1
7.7
5.1
8.1
4.9
7.1
5.1
7.3
5.1
7.7
5.1
8.1
4.9
7.1
5.1
7.3
5.1
7.7
5.1
8.1
4.9
7.1
5.1
7.3
5.1
7.7
5.1
8.1
4.9
7.1
5.1
7.3
5.1
7.7
5.1
8.1
4.9
7.0
5.0
7.2
5.0
7.6
5.0
7.9
4.8
6.8
4.8
7.0
4.8
7.4
4.8
7.8
4.6
9-8 -5
Cooling capacity (cont.)
Unit
size
027
036
048
Outdoor
air temp.
°CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
16.0°CWB
23°CDB
TC
SHC
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.3
5.3
7.1
5.2
7.0
5.0
10.2
7.2
10.2
7.2
10.2
7.2
10.2
7.2
10.2
7.2
10.2
7.2
10.2
7.2
10.2
7.2
10.2
7.2
10.2
7.2
10.2
7.2
10.2
7.2
10.2
7.2
10.2
7.2
10.0
7.0
9.8
6.8
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.5
9.1
12.2
8.7
18.0°CWB
26°CDB
TC
SHC
7.8
5.6
7.8
5.6
7.8
5.6
7.8
5.6
7.8
5.6
7.8
5.6
7.8
5.6
7.8
5.6
7.8
5.6
7.8
5.6
7.8
5.6
7.8
5.6
7.8
5.6
7.8
5.6
7.6
5.5
7.4
5.3
10.9
7.6
10.9
7.6
10.9
7.6
10.9
7.6
10.9
7.6
10.9
7.6
10.9
7.6
10.9
7.6
10.9
7.6
10.9
7.6
10.9
7.6
10.9
7.6
10.9
7.6
10.9
7.6
10.6
7.5
10.4
7.2
13.6
9.8
13.6
9.8
13.6
9.8
13.6
9.8
13.6
9.8
13.6
9.8
13.6
9.8
13.6
9.8
13.6
9.8
13.6
9.8
13.6
9.8
13.6
9.8
13.6
9.8
13.6
9.8
13.3
9.6
13.0
9.2
Indoor air temp.
19.0°CWB
27°CDB
TC
SHC
8.0
5.6
8.0
5.6
8.0
5.6
8.0
5.6
8.0
5.6
8.0
5.6
8.0
5.6
8.0
5.6
8.0
5.6
8.0
5.6
8.0
5.6
8.0
5.6
8.0
5.6
8.0
5.6
7.8
5.5
7.7
5.3
11.2
7.6
11.2
7.6
11.2
7.6
11.2
7.6
11.2
7.6
11.2
7.6
11.2
7.6
11.2
7.6
11.2
7.6
11.2
7.6
11.2
7.6
11.2
7.6
11.2
7.6
11.2
7.6
11.0
7.4
10.8
7.2
14.0
9.8
14.0
9.8
14.0
9.8
14.0
9.8
14.0
9.8
14.0
9.8
14.0
9.8
14.0
9.8
14.0
9.8
14.0
9.8
14.0
9.8
14.0
9.8
14.0
9.8
14.0
9.8
13.7
9.6
13.4
9.2
20.0°CWB
28°CDB
TC
SHC
8.2
5.6
8.2
5.6
8.2
5.6
8.2
5.6
8.2
5.6
8.2
5.6
8.2
5.6
8.2
5.6
8.2
5.6
8.2
5.6
8.2
5.6
8.2
5.6
8.2
5.6
8.2
5.6
8.1
5.5
7.9
5.3
11.5
7.6
11.5
7.6
11.5
7.6
11.5
7.6
11.5
7.6
11.5
7.6
11.5
7.6
11.5
7.6
11.5
7.6
11.5
7.6
11.5
7.6
11.5
7.6
11.5
7.6
11.5
7.6
11.3
7.4
11.1
7.1
14.4
9.8
14.4
9.8
14.4
9.8
14.4
9.8
14.4
9.8
14.4
9.8
14.4
9.8
14.4
9.8
14.4
9.8
14.4
9.8
14.4
9.8
14.4
9.8
14.4
9.8
14.4
9.8
14.1
9.6
13.8
9.2
9-8 -6
22.0°CWB
30°CDB
TC
SHC
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.7
5.5
8.5
5.4
8.4
5.2
12.2
7.5
12.2
7.5
12.2
7.5
12.2
7.5
12.2
7.5
12.2
7.5
12.2
7.5
12.2
7.5
12.2
7.5
12.2
7.5
12.2
7.5
12.2
7.5
12.2
7.5
12.2
7.5
12.0
7.4
11.7
7.1
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.3
9.7
15.0
9.5
14.6
9.1
24.0°CWB
32°CDB
TC
SHC
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
9.1
5.4
8.9
5.3
8.8
5.1
12.8
7.4
12.8
7.4
12.8
7.4
12.8
7.4
12.8
7.4
12.8
7.4
12.8
7.4
12.8
7.4
12.8
7.4
12.8
7.4
12.8
7.4
12.8
7.4
12.8
7.4
12.8
7.4
12.5
7.2
12.3
6.9
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
16.0
9.5
15.6
9.3
15.3
8.9
Heating capacity
Unit
size
015
018
024
Outdoor
air temp.
°CWB
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
SHC
3.1
3.3
3.6
3.7
3.9
4.1
4.3
4.5
4.7
4.8
5.0
5.2
5.2
5.2
5.2
5.2
3.9
4.2
4.5
4.6
4.9
5.1
5.4
5.6
5.9
6.1
6.3
6.6
6.6
6.6
6.6
6.6
5.0
5.3
5.7
5.8
6.2
6.5
6.8
7.1
7.4
7.7
8.0
8.3
8.3
8.3
8.3
8.3
SHC : Sensible Heat Capacity (kW)
Indoor air temp. °CDB
18.0
20.0
22.0
24.0
SHC
SHC
SHC
SHC
3.1
3.0
2.9
2.9
3.3
3.2
3.1
3.0
3.5
3.4
3.3
3.2
3.6
3.5
3.4
3.3
3.8
3.7
3.6
3.5
4.0
3.9
3.8
3.7
4.2
4.1
4.0
3.9
4.4
4.3
4.2
4.1
4.6
4.5
4.4
4.2
4.7
4.6
4.5
4.4
4.9
4.8
4.7
4.6
5.1
5.0
4.9
4.8
5.1
5.0
4.9
4.8
5.1
5.0
4.9
4.8
5.1
5.0
4.9
4.8
5.1
5.0
4.9
4.8
3.9
3.8
3.7
3.6
4.1
4.0
3.9
3.8
4.4
4.3
4.2
4.1
4.5
4.4
4.3
4.2
4.8
4.7
4.6
4.4
5.0
4.9
4.8
4.7
5.3
5.2
5.0
4.9
5.5
5.4
5.3
5.1
5.8
5.6
5.5
5.3
6.0
5.9
5.7
5.6
6.2
6.1
5.9
5.8
6.4
6.3
6.1
6.0
6.4
6.3
6.1
6.0
6.4
6.3
6.1
6.0
6.4
6.3
6.1
6.0
6.4
6.3
6.1
6.0
4.9
4.8
4.7
4.6
5.2
5.1
5.0
4.9
5.6
5.5
5.3
5.2
5.7
5.6
5.5
5.3
6.1
5.9
5.8
5.6
6.4
6.2
6.1
5.9
6.7
6.6
6.4
6.2
7.0
6.9
6.7
6.5
7.3
7.1
7.0
6.8
7.6
7.4
7.3
7.1
7.9
7.7
7.5
7.3
8.2
8.0
7.8
7.6
8.2
8.0
7.8
7.6
8.2
8.0
7.8
7.6
8.2
8.0
7.8
7.6
8.2
8.0
7.8
7.6
9-8 -7
Heating capacity (cont.)
Unit
size
027
036
048
Outdoor
air temp.
°CWB
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
SHC
5.6
6.0
6.4
6.6
7.0
7.3
7.7
8.0
8.4
8.7
9.0
9.4
9.4
9.4
9.4
9.4
7.8
8.3
8.9
9.1
9.7
10.2
10.7
11.1
11.6
12.1
12.6
13.0
13.0
13.0
13.0
13.0
10.0
10.7
11.4
11.7
12.4
13.0
13.6
14.3
14.9
15.5
16.1
16.7
16.7
16.7
16.7
16.7
Indoor air temp. °CDB
18.0
20.0
22.0
SHC
SHC
SHC
5.5
5.4
5.3
5.9
5.8
5.6
6.3
6.1
6.0
6.5
6.3
6.2
6.8
6.7
6.5
7.2
7.0
6.9
7.5
7.4
7.2
7.9
7.7
7.5
8.2
8.0
7.8
8.5
8.4
8.2
8.9
8.7
8.5
9.2
9.0
8.8
9.2
9.0
8.8
9.2
9.0
8.8
9.2
9.0
8.8
9.2
9.0
8.8
7.7
7.5
7.3
8.2
8.0
7.8
8.7
8.5
8.3
9.0
8.8
8.6
9.5
9.3
9.1
10.0
9.8
9.5
10.5
10.2
10.0
10.9
10.7
10.5
11.4
11.2
10.9
11.9
11.6
11.3
12.3
12.1
11.8
12.8
12.5
12.2
12.8
12.5
12.2
12.8
12.5
12.2
12.8
12.5
12.2
12.8
12.5
12.2
9.8
9.6
9.4
10.5
10.3
10.0
11.1
10.9
10.7
11.5
11.2
11.0
12.1
11.9
11.6
12.8
12.5
12.2
13.4
13.1
12.8
14.0
13.7
13.4
14.6
14.3
14.0
15.2
14.9
14.5
15.8
15.4
15.1
16.3
16.0
15.6
16.3
16.0
15.6
16.3
16.0
15.6
16.3
16.0
15.6
16.3
16.0
15.6
24.0
SHC
5.1
5.5
5.8
6.0
6.3
6.7
7.0
7.3
7.6
7.9
8.3
8.6
8.6
8.6
8.6
8.6
7.2
7.6
8.1
8.3
8.8
9.3
9.7
10.2
10.6
11.0
11.5
11.9
11.9
11.9
11.9
11.9
9.1
9.7
10.4
10.7
11.3
11.9
12.4
13.0
13.6
14.1
14.7
15.2
15.2
15.2
15.2
15.2
9-8 -8
9-8-5. Air throw distance chart
MMC-AP0181H,AP0481H
1m
MMC-AP0361H
1m
2m
2m
1.0
3m
0.3
1m
3m
4m
1m
1m
2m
1.0
0.3
0.3
1m
2m
0.3
0.5
MMC-AP015H,AP0241H,AP0271H
3m
0.3
0.5
3m
0.5
2m
1.0
0.3
0.5
3m
4m
9-8 -9
2m
3m
4m
9-8-6. Sound characteristics (NC-Curve)
Sound level values shown are based on a measurement in a non resound room.
MMC-AP0151H
H
M
L
35
32
30
Octave band sound pressure level (dB)
Fan Tap
Sound pressure
level (dB(A))
Microphone
90
H
M
L
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
continuous white level
10
NC-20
~
75
~
150
~
300
~
600
~
1200
~
2400
~
4800
75
150
300
600
1200
2400
4800
9600
~
20
Octave band frequency (Hz)
MMC-AP0181H
MMC-AP0241H,AP0271H
H
M
L
Fan Tap
H
M
L
Sound pressure
level (dB(A))
36
33
30
Sound pressure
level (dB(A))
38
36
33
Octave band sound pressure level (dB)
90
H
M
L
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
NC-20
Audibility limits of
continuous white level
10
Octave band sound pressure level (dB)
Fan Tap
90
H
M
L
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
continuous white level
10
NC-20
~
75
~
150
~
300
~
600
~
1200
~
2400
~
4800
~
20
~
75
~
150
~
300
~
600
~
1200
~
2400
~
4800
75
150
300
600
1200
2400
4800
9600
75
150
300
600
1200
2400
4800
9600
Octave band frequency (Hz)
Octave band frequency (Hz)
MMC-AP0361H
MMC-AP0481H
Fan Tap
H
M
L
Fan Tap
H
M
L
Sound pressure
level (dB(A))
41
38
35
Sound pressure
level (dB(A))
43
40
37
90
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
NC-20
Audibility limits of
continuous white level
10
NC-40
30
NC-30
20
NC-20
Audibility limits of
continuous white level
10
75
150
300
600
1200
2400
4800
9600
75
150
300
600
1200
2400
4800
9600
Octave band frequency (Hz)
Octave band frequency (Hz)
9-8 -10
~
20
~
~
4800
4800
40
~
~
2400
2400
NC-50
~
~
1200
1200
NC-60
50
~
~
600
600
60
~
~
300
300
NC-70
~
~
150
150
70
~
75
75
H
M
L
80
~
20
Octave band sound pressure level (dB)
90
H
M
L
~
Octave band sound pressure level (dB)
~
20
9-8-7. Accessories
Apperarance
Standard accessories
Part name
Qty
Shape
Use
Part name
Qty
Shape
Use
Installation
Manual
1
(Be sure to hand over to the
customer)
Heat
insulator
1
For heat insulation of drain
connecting section
Heat
insulating
pipe
2
For heat insulation of pipe
connecting section
Washer
4
For hanging-down unit
Installation
pattern
1
For confirmation of ceiling
opening and main unit
position
Hose band
2
For connecting drain pipe
Banding
band
2
For drain hose forming
Drain hose
1
For drain piping
Bushing
1
For power supply cord
protection
Heat
insulator
1
For sealing of piping hole
Remote controller
Model Name
Wired remote controller
RBC-AMT31E
Simple wired remote controller
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E2
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
Central remote controller
TCB-SC642TLE2
ON-OFF controller
TCB-CC163TLE2
9-8 -11
Optional accessories
Elbow piping kit
TCB-KP12CE2
TCB-KP22CE2
Drain pump kit
TCB-DP22CE2
Name
Drain Pump Kit
Elbow Piping Kit
Model name
TCB-DP22CE
TCB-KP12CE
Note
Stand-up 600 or less
(from bottom face of ceiling)
MMC-AP0151/0181H Type
(Use with TCB-KP12CE)
MMC-AP0241H/0271/0361H/0481H (Use with
TCB-KP22CE)
Needed when Drain Pump Kid is used
TCB-KP22CE
9-8 -12
9-9-1. Specifications
50Hz
Specifications (50Hz)
Model name
MMK-
AP0071H
AP0091H
AP0121H
AP0151H
AP0181H
AP0241H
(kW)
2.2/2.5
2.8/3.2
3.6/4.0
4.5/5.0
5.6/6.3
7.1/8.0
Cooling/Heating capacity (Note 1)
1 phase 50Hz 230V (220-240V) (Separate power supply for indoor units is required.)
Power supply
Electrical
characteristics
Running current
Power consumption
(A)
0.30
0.32
0.35
(kW)
0.035
0.037
0.040
(A)
0.36
0.42
0.47
Starting current
Suction grille and side panel
Appearance
Outer
dimension
Silky mist (Munsell 1Y 8.9/0.5)
Discharge grille
City gray (Munsell N6.5)
Bottom surface
Silky mist (Munsell 1Y 8.9/0.5)
Height x Width x Depth
Total weight
(mm)
368 x 895 x 210
368 x 1,055 x 210
368 x 1,430 x 210
(kg)
18
19
25
780/660/600
1,200/1,020/900
Heat exchanger
Finned tube
Soundproof/Heat-insulating material
Non-flammable insulation
Cross-flow fan
Fan
Fan unit
Standard air flow
(High/Mid/Low)
Motor outlet
(m3/h)
600/540/480
30
(W)
Standard filter (Simple filter)
Air filter
Remote controller
Controller
Gas side
Connecting
Liquid side
pipe
(mm)
O
/ 9.5
O
/ 6.4
(mm)
(dB(A))
O
/ 15.9
O
/ 9.5
20 (Polyvinyl chloride tube)
Drain port (Nominal dia. mm)
Sound pressure level (Note 2)
(High/Mid/Low)
O
/ 12.7
39/34/31
PMV Kit
42/38/35
42/38/35
Available
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the
actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB
Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB/6oC WB
9-9 -1
60Hz
Specifications (60Hz)
Model name
Cooling/Heating capacity (Note 1)
MMK-
AP0071H
AP0091H
AP0121H
AP0151H
AP0181H
AP0241H
(kW)
2.2/2.5
2.8/3.2
3.6/4.0
4.5/5.0
5.6/6.3
7.1/8.0
1 phase 60Hz 220V (Separate power supply for indoor units is required.)
Power supply
Running current
Electrical
characteristics
Power consumption
(A)
0.32
0.34
0.35
(kW)
0.035
0.037
0.040
(A)
0.46
0.48
0.60
Starting current
Silky mist (Munsell 1Y 8.9/0.5)
Suction grille and side panel
Appearance
Outer
dimension
Discharge grille
City gray (Munsell N6.5)
Bottom surface
Silky mist (Munsell 1Y 8.9/0.5)
Height x Width x Depth
Total weight
(mm)
368 x 895 x 210
368 x 1,055 x 210
368 x 1,430 x 210
(kg)
18
19
25
780/660/600
1,200/1,020/900
Finned tube
Heat exchanger
Non-flammable insulation
Soundproof/Heat-insulating material
Cross-flow fan
Fan
Fan
Standard air flow (High/Mid/Low)
unit
(m3/h)
600/540/480
(W)
Motor outlet
30
Air filter
Standard filter (Simple filter)
Controller
Connecting pipe
Remote controller
Gas side
(mm)
Liquid side
(mm)
O
/ 9.5
O
/ 12.7
O
/ 6.4
Drain port (Nominal dia. mm)
Sound pressure level (Note 2)
(High/Mid/Low)
(dB(A))
O
/ 15.9
O
/ 9.5
20 (Polyvinyl chloride tube)
39/34/31
42/38/35
PMV Kit
42/38/35
Available
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in
the actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions
Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
O
O
O
9-9 -2
O
O
O
9-9-2. Dimension
MMK-AP0071H, AP0091H, AP0121H
Position of holes on the installation plate.
Long hole for
wooden screw
15-6 X 30
690 (Installation plate)
Hole for anchor bolt
10-10 X 20 long hole
(Including installation plate)
210
Including installation plate (Accessory)
Earth screw (M4)
(Inside of electric parts box)
Upper end of installation plate
Refrigerant pipe
connecting port
O
Gas side 9.5
/ 9.5
Refrigerant pipe
connecting port
Liquid side O
/ 6.4
Drain pipe
connecting port
Air suction port
Discharge port
(Air direction upward/downward/leftward/rightward are adjustable.)
Piping port from left/right sides
(Knockout hole)
30 or more
Gas pipe 440
Liquid pipe 540
Drain pipe 560
At shipment
(When drawing pipe from left)
300 or more
300 or more
Space required for service
2.7
Wired remote controller
RBC-AMT31E
4 remote controller
Simple wired
RBC-AS21E2
120
Wireless remote controller kit
TCB-AX21E2
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
120
16
Note: All dimensions are in mm.
9-9 -3
MMK-AP0151H, AP0181H
182.5
Hole for
wooden screw
15-6 X 30
182.5
690 (Installation plate)
Hole for anchor bolt
10-10 X 20 long hole
(Including installation plate)
210
Including installation plate (Accessory)
Earth screw (M4)
(Inside of electric parts box)
Refrigerant pipe
Refrigerant pipe
connecting port
connecting port
Liquid side O
/ 6.4 Gas side O/ 12.7
Upper end of installation plate
Air suction port
Air discharge port
(Air direction upward/downward/leftward/rightward air adjustable.)
Drain pipe
connecting port
Piping port from left/right sides
(Knockout hole)
30 or more
Gas pipe 440
Liquid pipe 540
Drain pipe 560
At shipment
(When drawing pipe from left)
300 or more
Wired remote controller
RBC-AMT31E
300 or more
Space required for service
Simple wired remote controller
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E2
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
Note: All dimensions are in mm.
9-9 -4
MMK-AP0241H
Position of holes on the installation plate
Hole for
wooden screw
21-6 X 30
170
1090 (Installation plate)
Hole for anchor bolt
16-10 X 20 long hole
170
(Including installation plate)
210
Including installation plate (Accessory)
Earth screw (M4)
(Inside of electric parts box)
Upper end of installation plate
Refrigerant pipe
connecting port
Gas side O
/ 15.9
Air discharge port (Air direction upward/ Air suction port
downward/leftward/rightward air adjustable.)
Refrigerant pipe
connecting port
Liquid side O
/ 9.5
Drain pipe
connecting port
Piping port from left/right sides
(Knockout hole)
30 or more
Gas pipe 440
Liquid pipe 540
Drain pipe 560
At shipment
(When drawing pipe from left)
300 or more
300 or more
Space required for service
Wired remote controller
RBC-AMT31E
Simple wired remote controller
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E2
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
Note: All dimensions are in mm.
9-9 -5
9-9 -6
RED : RED
WHI : WHITE
YEL :YELLOW
BLU : BLUE
BLK : BLACK
GRY : GRAY
PNK : PINK
ORN :ORANGE
BRN : BROWN
GRN : GREEN
Color
indication
Earth screw
Indoor unit
Power supply
single phase
220-240V 50Hz
220V 60Hz
R(L) S(N)
Outdoor
unit
X
GRY
1 2
1 2
CN001
(WHI)
BLK
Wired remote Adapter for
controller wireless remote
controller
1 2
1 2
CN1
(WHI)
Y
GRY
BLK
BLK
BLK
WHI
1 2 3
1
3
1 2
1 2
BLU
BLU
CN41
(BLU)
CN40
(BLU)
CN50
(WHI)
1 2
1 2
CN03(RED)
CN01(WHI)
CN02
(BLU)
1 2
1 2
1 2 3 4 5 6
Network Adapter
(Option)
MCC-1401
3 3
2
1 1
TR
1 2 3 4 5
CN61
(YEL)
3
3
1 1
2 2
TC2
Option
1 2 3 4 5
CN81
(BLK)
1 2 3 4 5
CN20
(BLU)
CN70
(WHI)
CN73
(RED)
CN080
(GRN)
CN100
(BRW)
CN103
(GRN)
1
3
1 2 3
TC1
1
2
1
2 EXCT
1
2
3
1
2
3.
Symbol
FM
TA
TC1,TC2,TCJ
PMV
LM
RY303
Parts name
Fan motor
Indoor temp sensor
Temp sensor
Pulse motor valve
Lover motor
Louver control relay
indicates the control P.C. board.
2 . A dotted line and broken line indicate the wiring on site.
indicates the terminal number.
indicates the terminal block, the letter inside
1 2 3 4 5 6
1.
1 1
2 2
TCJ
CN104 CN102 CN101
(YEL) (RED) (BLK)
1 1
2 2
TA
Control P.C. board
for Indoor unit
MCC-1402
1 2
CN60
(WHI)
DC20V
DC15V
DC12V
DC7V
CN34
(RED)
1
1
Fandrive
CN32
(WHI)
Power
supply
circuit
CN33
(WHI)
CN82
(BLU)
FUSE
1 2 3 4 5
1 2 3 4 5 6
1 2 3 4 5 6
T3.15A 250V~
3 CN309
3 (YEL)
5
5
6 4 3 1 2 5
6 4 3 1 2 5
PMV
FUSE
1
1
3
3
Motor drive
circuit
CN333 1
(WHI) 1
1 2 3
1 2 3
FM
T6.3A 250V~
RY303
RY302
BLK WHI
B
CN66
(WHI)
1
2
P301
BLK
3 3
CN67
(BLK)
1 1
3 3
CN304
(GRY)
A
WHI
U1 U2
U1 U2
RED
Closed-end
connector
WHI
Flow selector
unit earth
screw
WHI
RED
LM
3
1
1 1
CN68
(BLU)
CN334 5 4
2 1
(WHI) 5 4 3 2 1
1 1
5 5
4 4
9-9-3. Wiring diagram
Model: MMK-AP0071H, AP0091H, AP0121H, AP0151H, AP0181H, AP0241H
9-9-4. Sensible capacity table
(MMD-AP***H)
Cooling capacity
Unit
size
007
009
012
Outdoor
air temp.
°CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
16.0°CWB
23°CDB
TC
SHC
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
1.9
1.5
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.4
1.8
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.2
2.3
3.1
2.2
18.0°CWB
26°CDB
TC
SHC
2.1
1.7
2.1
1.7
2.1
1.7
2.1
1.7
2.1
1.7
2.1
1.7
2.1
1.7
2.1
1.7
2.1
1.7
2.1
1.7
2.1
1.7
2.1
1.7
2.1
1.7
2.1
1.7
2.1
1.7
2.0
1.6
2.7
2.0
2.7
2.0
2.7
2.0
2.7
2.0
2.7
2.0
2.7
2.0
2.7
2.0
2.7
2.0
2.7
2.0
2.7
2.0
2.7
2.0
2.7
2.0
2.7
2.0
2.7
2.0
2.7
2.0
2.6
1.9
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.4
2.5
3.4
2.4
TC : Total Capacity (kW) SHC : Sensible Heat Capacity (kW)
Indoor air temp.
19.0°CWB
20.0°CWB
22.0°CWB
24.0°CWB
27°CDB
28°CDB
30°CDB
32°CDB
TC
SHC
TC
SHC
TC
SHC
TC
SHC
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.2
1.7
2.4
1.7
2.5
1.6
2.1
1.6
2.2
1.6
2.3
1.6
2.4
1.5
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.7
2.0
2.8
2.0
3.0
1.9
3.1
1.9
2.7
1.9
2.8
1.9
2.9
1.9
3.1
1.8
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.5
2.5
3.6
2.4
3.8
2.4
4.0
2.4
3.5
2.4
3.6
2.4
3.8
2.3
3.9
2.3
9-9 -7
Cooling capacity (cont.)
Unit
size
015
018
024
Outdoor
air temp.
°CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
16.0°CWB
23°CDB
TC
SHC
4.1
2.7
4.1
2.7
4.1
2.7
4.1
2.7
4.1
2.7
4.1
2.7
4.1
2.7
4.1
2.7
4.1
2.7
4.1
2.7
4.1
2.7
4.1
2.7
4.1
2.7
4.1
2.7
4.0
2.7
3.9
2.6
5.1
3.4
5.1
3.4
5.1
3.4
5.1
3.4
5.1
3.4
5.1
3.4
5.1
3.4
5.1
3.4
5.1
3.4
5.1
3.4
5.1
3.4
5.1
3.4
5.1
3.4
5.1
3.4
5.0
3.3
4.9
3.2
6.4
4.4
6.4
4.4
6.4
4.4
6.4
4.4
6.4
4.4
6.4
4.4
6.4
4.4
6.4
4.4
6.4
4.4
6.4
4.4
6.4
4.4
6.4
4.4
6.4
4.4
6.4
4.4
6.3
4.3
6.2
4.2
18.0°CWB
26°CDB
TC
SHC
4.4
2.9
4.4
2.9
4.4
2.9
4.4
2.9
4.4
2.9
4.4
2.9
4.4
2.9
4.4
2.9
4.4
2.9
4.4
2.9
4.4
2.9
4.4
2.9
4.4
2.9
4.4
2.9
4.3
2.9
4.2
2.7
5.4
3.6
5.4
3.6
5.4
3.6
5.4
3.6
5.4
3.6
5.4
3.6
5.4
3.6
5.4
3.6
5.4
3.6
5.4
3.6
5.4
3.6
5.4
3.6
5.4
3.6
5.4
3.6
5.3
3.5
5.2
3.4
6.9
4.7
6.9
4.7
6.9
4.7
6.9
4.7
6.9
4.7
6.9
4.7
6.9
4.7
6.9
4.7
6.9
4.7
6.9
4.7
6.9
4.7
6.9
4.7
6.9
4.7
6.9
4.7
6.7
4.6
6.6
4.4
Indoor air temp.
19.0°CWB
27°CDB
TC
SHC
4.5
2.9
4.5
2.9
4.5
2.9
4.5
2.9
4.5
2.9
4.5
2.9
4.5
2.9
4.5
2.9
4.5
2.9
4.5
2.9
4.5
2.9
4.5
2.9
4.5
2.9
4.5
2.9
4.4
2.8
4.3
2.7
5.6
3.6
5.6
3.6
5.6
3.6
5.6
3.6
5.6
3.6
5.6
3.6
5.6
3.6
5.6
3.6
5.6
3.6
5.6
3.6
5.6
3.6
5.6
3.6
5.6
3.6
5.6
3.6
5.5
3.5
5.4
3.4
7.1
4.7
7.1
4.7
7.1
4.7
7.1
4.7
7.1
4.7
7.1
4.7
7.1
4.7
7.1
4.7
7.1
4.7
7.1
4.7
7.1
4.7
7.1
4.7
7.1
4.7
7.1
4.7
7.0
4.6
6.8
4.4
9-9 -8
20.0°CWB
28°CDB
TC
SHC
4.6
2.9
4.6
2.9
4.6
2.9
4.6
2.9
4.6
2.9
4.6
2.9
4.6
2.9
4.6
2.9
4.6
2.9
4.6
2.9
4.6
2.9
4.6
2.9
4.6
2.9
4.6
2.9
4.5
2.8
4.4
2.7
5.8
3.6
5.8
3.6
5.8
3.6
5.8
3.6
5.8
3.6
5.8
3.6
5.8
3.6
5.8
3.6
5.8
3.6
5.8
3.6
5.8
3.6
5.8
3.6
5.8
3.6
5.8
3.6
5.7
3.5
5.5
3.4
7.3
4.7
7.3
4.7
7.3
4.7
7.3
4.7
7.3
4.7
7.3
4.7
7.3
4.7
7.3
4.7
7.3
4.7
7.3
4.7
7.3
4.7
7.3
4.7
7.3
4.7
7.3
4.7
7.2
4.6
7.0
4.4
22.0°CWB
30°CDB
TC
SHC
4.9
2.9
4.9
2.9
4.9
2.9
4.9
2.9
4.9
2.9
4.9
2.9
4.9
2.9
4.9
2.9
4.9
2.9
4.9
2.9
4.9
2.9
4.9
2.9
4.9
2.9
4.9
2.9
4.8
2.8
4.7
2.7
6.1
3.6
6.1
3.6
6.1
3.6
6.1
3.6
6.1
3.6
6.1
3.6
6.1
3.6
6.1
3.6
6.1
3.6
6.1
3.6
6.1
3.6
6.1
3.6
6.1
3.6
6.1
3.6
6.0
3.5
5.9
3.4
7.7
4.7
7.7
4.7
7.7
4.7
7.7
4.7
7.7
4.7
7.7
4.7
7.7
4.7
7.7
4.7
7.7
4.7
7.7
4.7
7.7
4.7
7.7
4.7
7.7
4.7
7.7
4.7
7.6
4.6
7.4
4.4
24.0°CWB
32°CDB
TC
SHC
5.1
2.8
5.1
2.8
5.1
2.8
5.1
2.8
5.1
2.8
5.1
2.8
5.1
2.8
5.1
2.8
5.1
2.8
5.1
2.8
5.1
2.8
5.1
2.8
5.1
2.8
5.1
2.8
5.0
2.8
4.9
2.6
6.4
3.5
6.4
3.5
6.4
3.5
6.4
3.5
6.4
3.5
6.4
3.5
6.4
3.5
6.4
3.5
6.4
3.5
6.4
3.5
6.4
3.5
6.4
3.5
6.4
3.5
6.4
3.5
6.3
3.4
6.1
3.3
8.1
4.5
8.1
4.5
8.1
4.5
8.1
4.5
8.1
4.5
8.1
4.5
8.1
4.5
8.1
4.5
8.1
4.5
8.1
4.5
8.1
4.5
8.1
4.5
8.1
4.5
8.1
4.5
7.9
4.5
7.8
4.3
Heating capacity
Unit
size
007
009
012
Outdoor
air temp.
°CWB
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
SHC
1.6
1.7
1.8
1.8
1.9
2.0
2.1
2.2
2.3
2.4
2.5
2.6
2.6
2.6
2.6
2.6
2.0
2.1
2.3
2.3
2.5
2.6
2.7
2.9
3.0
3.1
3.2
3.3
3.3
3.3
3.3
3.3
2.5
2.7
2.8
2.9
3.1
3.3
3.4
3.6
3.7
3.9
4.0
4.2
4.2
4.2
4.2
4.2
SHC : Sensible Heat Capacity (kW)
Indoor air temp. °CDB
18.0
20.0
22.0
24.0
SHC
SHC
SHC
SHC
1.5
1.5
1.5
1.4
1.6
1.6
1.6
1.5
1.7
1.7
1.7
1.6
1.8
1.8
1.7
1.7
1.9
1.9
1.8
1.8
2.0
2.0
1.9
1.9
2.1
2.0
2.0
1.9
2.2
2.1
2.1
2.0
2.3
2.2
2.2
2.1
2.4
2.3
2.3
2.2
2.5
2.4
2.4
2.3
2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.0
1.9
1.9
1.8
2.1
2.1
2.0
1.9
2.2
2.2
2.1
2.1
2.3
2.2
2.2
2.1
2.4
2.4
2.3
2.3
2.6
2.5
2.4
2.4
2.7
2.6
2.6
2.5
2.8
2.7
2.7
2.6
2.9
2.9
2.8
2.7
3.0
3.0
2.9
2.8
3.2
3.1
3.0
2.9
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
2.5
2.4
2.3
2.3
2.6
2.6
2.5
2.4
2.8
2.7
2.7
2.6
2.9
2.8
2.7
2.7
3.0
3.0
2.9
2.8
3.2
3.1
3.0
3.0
3.3
3.3
3.2
3.1
3.5
3.4
3.3
3.3
3.7
3.6
3.5
3.4
3.8
3.7
3.6
3.5
3.9
3.9
3.8
3.7
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
9-9 -9
Heating capacity (cont.)
Unit
size
015
018
024
Outdoor
air temp.
°CWB
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
SHC
3.1
3.3
3.6
3.7
3.9
4.1
4.3
4.5
4.7
4.8
5.0
5.2
5.2
5.2
5.2
5.2
3.9
4.2
4.5
4.6
4.9
5.1
5.4
5.6
5.9
6.1
6.3
6.6
6.6
6.6
6.6
6.6
5.0
5.3
5.7
5.8
6.2
6.5
6.8
7.1
7.4
7.7
8.0
8.3
8.3
8.3
8.3
8.3
Indoor air temp. °CDB
18.0
20.0
22.0
SHC
SHC
SHC
3.1
3.0
2.9
3.3
3.2
3.1
3.5
3.4
3.3
3.6
3.5
3.4
3.8
3.7
3.6
4.0
3.9
3.8
4.2
4.1
4.0
4.4
4.3
4.2
4.6
4.5
4.4
4.7
4.6
4.5
4.9
4.8
4.7
5.1
5.0
4.9
5.1
5.0
4.9
5.1
5.0
4.9
5.1
5.0
4.9
5.1
5.0
4.9
3.9
3.8
3.7
4.1
4.0
3.9
4.4
4.3
4.2
4.5
4.4
4.3
4.8
4.7
4.6
5.0
4.9
4.8
5.3
5.2
5.0
5.5
5.4
5.3
5.8
5.6
5.5
6.0
5.9
5.7
6.2
6.1
5.9
6.4
6.3
6.1
6.4
6.3
6.1
6.4
6.3
6.1
6.4
6.3
6.1
6.4
6.3
6.1
4.9
4.8
4.7
5.2
5.1
5.0
5.6
5.5
5.3
5.7
5.6
5.5
6.1
5.9
5.8
6.4
6.2
6.1
6.7
6.6
6.4
7.0
6.9
6.7
7.3
7.1
7.0
7.6
7.4
7.3
7.9
7.7
7.5
8.2
8.0
7.8
8.2
8.0
7.8
8.2
8.0
7.8
8.2
8.0
7.8
8.2
8.0
7.8
24.0
SHC
2.9
3.0
3.2
3.3
3.5
3.7
3.9
4.1
4.2
4.4
4.6
4.8
4.8
4.8
4.8
4.8
3.6
3.8
4.1
4.2
4.4
4.7
4.9
5.1
5.3
5.6
5.8
6.0
6.0
6.0
6.0
6.0
4.6
4.9
5.2
5.3
5.6
5.9
6.2
6.5
6.8
7.1
7.3
7.6
7.6
7.6
7.6
7.6
9-9 -10
9-9-5. Air throw distance chart
MMK-AP0071H, AP0091H, AP0121H
Horizontal discharge
Initial speed High wind: 5.0m/s
Med. wind: 4.4m/s
Horizontal discharge
5
Air speed (m/s)
Air speed (m/s)
5
4
3
2
1
0
MMK-AP0151H, AP0181H
1
2
3
4
5
6
7
Initial speed High wind: 5.0m/s
Med. wind: 4.4m/s
4
3
2
1
0
Horizontal throw (m)
1
2
3
4
5
6
7
Horizontal throw (m)
MMK-AP0241H
Air speed (m/s)
Horizontal discharge
Initial speed High wind: 5.0m/s
Med. wind: 4.4m/s
5
4
3
2
1
0
1
2
3
4
5
6
7
Horizontal throw (m)
9-9 -11
(Revised edition in 7.Apr.2006)
9-9-6. Sound characteristics (NC-Curve)
MMK
-AP0071H, AP0091H, AP0121H
MMK-AP0071H,
Fan Tap
Sound pressure
level(dB(A))
[Measuring location]
H
M
L
39
34
31
Octave band sound pressure level (dB)
90
Microphone
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
M
M
30
Approximate threshold
of hearing for
continuous noise
20
NC-30
L
NC-20
10
60
125
250
500
1000
2000
4000
8000
Octave band frequency(Hz)
MMK
-AP0151H, AP0181H
MMK-AP0151H,
Fan Tap
Sound pressure
level(dB(A))
MMK
-AP0241H
MMK-AP0241H
H
M
L
42
38
35
Fan Tap
Sound pressure
level(dB(A))
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
M
L
38
35
90
90
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
H
M
30
NC-30
L
20
H
42
Approximate threshold
of hearing for
continuous noise
NC-20
10
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
H
M
30
NC-30
L
Approximate threshold
of hearing for
continuous noise
20
NC-20
10
63
125
250
500
1000
2000
4000
8000
63
Octave band frequency(Hz)
125
250
500
1000
2000
4000
Octave band frequency(Hz)
9-9 -12
(Revised edition in 7.Apr.2006)
8000
9-9-7. Accessories
Apperarance
Standard accessories
Part name
Qty
Shape
Use
Part name
Qty
Shape
Use
Installation
Manual
1
(Be sure to hand over to
customer)
Installation
pattern
1
Used for drilling holes and
positioning installation plate
Heat
Insulating
pipe
2
For heat insulating of pipe
connecting section
Screw cap
4
Cover on fixing screw at side
plate
Wood screw
Ø5.1 x 45
12
Used to fix installation plate
Bundling
band
4
Used to fix attached pipe heat
insulating material
Installation
plate
1
Used to install indoor unit wall
unit
Optional accessories
Remote controller
Model Name
Wired remote controller
RBC-AMT31E
Simple wired remote controller
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E2
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
Central remote controller
TCB-SC642TLE2
ON-OFF controller
TCB-CC163TLE2
9-9 -13
9-10-1. Specifications
50Hz
Specifications (50Hz)
Model name
MMK-
AP0072H
AP0092H
AP0122H
(kW)
2.2/2.5
2.8/3.2
3.6/4.0
Cooling/Heating capacity (Note 1)
1 phase 50Hz 230V (220-240V) (Separate power supply for indoor units is required.)
Power supply
Electrical
characteristics
(A)
0.17
0.18
0.19
(kW)
0.017
0.018
0.019
(A)
0.22
0.23
0.24
Running current
Power consumption
Starting current
Appearance
Outer
dimension
Suction grille and side panel
Moon white
Discharge grille
Moon white
Bottom surface
Moon white
Height x Width x Depth
Total weight
(mm)
275 x 790 x 208
(kg)
11
Finned tube
Heat exchanger
Non-flammable insulation
Soundproof/Heat-insulating material
Cross-flow fan
Fan
Fan unit
Standard air flow
(High/Mid/Low)
Motor outlet
(m3/h)
480/420/360
510/450/360
540/450/360
30
(W)
Standard filter (Simple filter)
Air filter
Wireless remote controller (WH-H2UE, Packed with indoor unit)
Controller
Gas side
Connecting
Liquid side
pipe
Drain port
(mm)
O
/ 9.5
(mm)
O
/ 6.4
(Nominal dia. mm)
Sound pressure level (Note 2)
(High/Mid/Low)
(dB(A))
16 (Polyvinyl chloride tube)
35/32/29
36/33/29
PMV Kit
37/33/29
Available
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the
actual operating environment become larger than the indicated values due to the effects of external sound.
Note 3 : Wireless remote controller is packed with indoor unit.
Wired remote controller (RBC-AMT31E, RBC-AS21E2) can be also connected.
Note : Rated conditions
Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB
Heating : 20oC DB, Outdoor air temperature 7oC DB/6oC WB
9-10 -1
60Hz
Specifications (60Hz)
Model name
MMK-
AP0072H
AP0092H
AP0122H
(kW)
2.2/2.5
2.8/3.2
3.6/4.0
Cooling/Heating capacity (Note 1)
1 phase 60Hz 220V (Separate power supply for indoor units is required.)
Power supply
Electrical
characteristics
Running current
Power consumption
(A)
0.18
0.19
0.20
(kW)
0.017
0.018
0.019
(A)
0.22
0.23
0.24
Starting current
Appearance
Outer
dimension
Suction grille and side panel
Moon white
Discharge grille
Moon white
Bottom surface
Moon white
Height x Width x Depth
Total weight
(mm)
275 x 790 x 208
(kg)
11
Heat exchanger
Finned tube
Soundproof/Heat-insulating material
Non-flammable insulation
Cross-flow fan
Fan
Fan unit
Standard air flow
(High/Mid/Low)
Motor outlet
(m3/h)
480/420/360
510/450/360
540/450/360
30
(W)
Standard filter (Simple filter)
Air filter
Wireless remote controller (WH-H2UE, Packed with indoor unit)
Controller
Gas side
Connecting
Liquid side
pipe
Drain port
(mm)
O
/ 9.5
(mm)
O
/ 6.4
(Nominal dia. mm)
Sound pressure level (Note 2)
(High/Mid/Low)
(dB(A))
16 (Polyvinyl chloride tube)
35/32/29
36/33/29
37/33/29
Available
PMV Kit
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the
actual operating environment become larger than the indicated values due to the effects of external sound.
Note 3 : Wireless remote controller is packed with indoor unit.
Wired remote controller (RBC-AMT31E, RBC-AS21E2) can be also connected.
Note : Rated conditions
Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB
Heating : 20oC DB, Outdoor air temperature 7oC DB/6oC WB
9-10 -2
9-10-2. Dimension
MMK-AP0072H, AP0092H, AP0122H
Air inlet part
790
275
275
208
275
208
Knockout
60
48
Air outlet gril
6
6
60
48
Knockout
54.5
60
60
48
48
208
790
54.5
208
790
275
790
Hock for insulation plate
Drain pipe
321
Refrigerant pipe connecting port
Liquid side O
/ 6.4
Refrigerant pipe connecting port
Gas side O
/ 9.5
100mm or more
170mm or more
*300mm or more
170mm or more
Wired remote controller
RBC-AMT31E
*(For attached Flow Selector unit of
heat recovery model)
Space required for service
Simple wired remote controller
RBC-AS21E2
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
Note: All dimensions are in mm.
9-10 -3
9-10-3. Wiring diagram
Model: MMK-AP0072H, AP0092H, AP0122H
9-10 -4
9-10-4. Sensible capacity table
(MMD-AP***H)
Cooling capacity
Unit
size
007
009
012
Outdoor
air temp.
˚CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
16.0˚CWB
23˚CDB
TC
SHC
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.6
1.9
1.5
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.5
1.9
2.4
1.8
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.3
2.4
3.2
2.3
3.1
2.2
18.0˚CWB
26˚CDB
TC
SHC
2.1
1.7
2.1
1.7
2.1
1.7
2.1
1.7
2.1
1.7
2.1
1.7
2.1
1.7
2.1
1.7
2.1
1.7
2.1
1.7
2.1
1.7
2.1
1.7
2.1
1.7
2.1
1.7
2.1
1.7
2.0
1.6
2.7
2.0
2.7
2.0
2.7
2.0
2.7
2.0
2.7
2.0
2.7
2.0
2.7
2.0
2.7
2.0
2.7
2.0
2.7
2.0
2.7
2.0
2.7
2.0
2.7
2.0
2.7
2.0
2.7
2.0
2.6
1.9
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.5
2.5
3.4
2.5
3.4
2.4
TC : Total Capacity (kW) SHC : Sensible Heat Capacity (kW)
Indoor air temp.
19.0˚CWB
20.0˚CWB
22.0˚CWB
24.0˚CWB
27˚CDB
28˚CDB
30˚CDB
32˚CDB
TC
SHC
TC
SHC
TC
SHC
TC
SHC
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.3
1.7
2.4
1.7
2.5
1.6
2.2
1.7
2.2
1.7
2.4
1.7
2.5
1.6
2.1
1.6
2.2
1.6
2.3
1.6
2.4
1.5
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.8
2.0
2.9
2.0
3.1
2.0
3.2
1.9
2.7
2.0
2.8
2.0
3.0
1.9
3.1
1.9
2.7
1.9
2.8
1.9
2.9
1.9
3.1
1.8
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.6
2.5
3.7
2.5
3.9
2.5
4.1
2.4
3.5
2.5
3.6
2.4
3.8
2.4
4.0
2.4
3.5
2.4
3.6
2.4
3.8
2.3
3.9
2.3
9-10 -5
Heating capacity
Unit
size
007
009
012
Outdoor
air temp.
˚CWB
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
SHC
1.6
1.7
1.8
1.8
1.9
2.0
2.1
2.2
2.3
2.4
2.5
2.6
2.6
2.6
2.6
2.6
2.0
2.1
2.3
2.3
2.5
2.6
2.7
2.9
3.0
3.1
3.2
3.3
3.3
3.3
3.3
3.3
2.5
2.7
2.8
2.9
3.1
3.3
3.4
3.6
3.7
3.9
4.0
4.2
4.2
4.2
4.2
4.2
SHC : Sensible Heat Capacity (kW)
Indoor air temp. ˚CDB
18.0
20.0
22.0
24.0
SHC
SHC
SHC
SHC
1.5
1.5
1.5
1.4
1.6
1.6
1.6
1.5
1.7
1.7
1.7
1.6
1.8
1.8
1.7
1.7
1.9
1.9
1.8
1.8
2.0
2.0
1.9
1.9
2.1
2.0
2.0
1.9
2.2
2.1
2.1
2.0
2.3
2.2
2.2
2.1
2.4
2.3
2.3
2.2
2.5
2.4
2.4
2.3
2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.0
1.9
1.9
1.8
2.1
2.1
2.0
1.9
2.2
2.2
2.1
2.1
2.3
2.2
2.2
2.1
2.4
2.4
2.3
2.3
2.6
2.5
2.4
2.4
2.7
2.6
2.6
2.5
2.8
2.7
2.7
2.6
2.9
2.9
2.8
2.7
3.0
3.0
2.9
2.8
3.2
3.1
3.0
2.9
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
2.5
2.4
2.3
2.3
2.6
2.6
2.5
2.4
2.8
2.7
2.7
2.6
2.9
2.8
2.7
2.7
3.0
3.0
2.9
2.8
3.2
3.1
3.0
3.0
3.3
3.3
3.2
3.1
3.5
3.4
3.3
3.3
3.7
3.6
3.5
3.4
3.8
3.7
3.6
3.5
3.9
3.9
3.8
3.7
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
9-10 -6
9-10-5. Air throw distance chart
Model : MMK-AP0072H, AP0092H, AP0122H
Horizontal discharge Initial speed
High wind : 4.5m/s
Med wind : 3.7m/s
Low wind : 3.2m/s
Air speed (m/s)
5
4
High
Mid
Low
3
2
1
0
0
1
2
3
4
Horizontal throw (m)
9-10 -7
5
6
7
9-10-6. Sound characteristics (NC-Curve)
Model : MMK-AP0072H, AP0092H, AP0122H
1m
1m
Microphone
MMK-AP0072H
Fan tap
H
M
L
Sound pressure level (dB(A))
35
32
29
Octave band sound pressure level (dB)
90
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
20
10
20-75
NC-30
Audibility limits of
continuous white level
75-150
NC-20
150-300
300-600
600-1200
1200-2400
Octave band frequency (Hz)
9-10 -8
2400-4800
4800-10000
MMK-AP0092H
Fan tap
H
M
L
Sound pressure level (dB(A))
36
33
29
Octave band sound pressure level (dB)
90
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
Audibility limits of
continuous white level
10
20-75
75-150
NC-20
150-300
300-600
600-1200
1200-2400
2400-4800
4800-10000
Octave band frequency (Hz)
MMK-AP0122H
Fan tap
H
M
L
Sound pressure level (dB(A))
35
33
29
Octave band sound pressure level (dB)
90
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
20
10
20-75
NC-30
Audibility limits of
continuous white level
75-150
NC-20
150-300
300-600
600-1200
1200-2400
Octave band frequency (Hz)
9-10 -9
2400-4800
4800-10000
9-10-7. Accessories
Apperarance
Standard accessories
Part
No.
Part name (Qty)
1
Part
No.
Part name (Qty)
3
Installation plate × 1
2
Part name (Qty)
5
Battery × 2
Mounting screw Ø4 × 25 x 6
4
Wireless remote controller × 1
Part
No.
6
Remote controller holder × 1
Optional accessories
Remote controller
Model Name
Wired remote controller
RBC-AMT31E
Simple wired remote controller
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E2
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
Central remote controller
TCB-SC642TLE2
ON-OFF controller
TCB-CC163TLE2
9-10 -10
Pan head wood screw Ø3.1 × 16 × 2
9-11-1. Specifications
50Hz
Specifications (50Hz)
Model name
Cooling/Heating capacity (Note 1)
MML-
AP0071H
AP0091H
AP0121H
AP0151H
AP0181H
AP0241H
(kW)
2.2/2.5
2.8/3.2
3.6/4.0
4.5/5.0
5.6/6.3
7.1/8.0
1 phase 50Hz 230V (220-240V) (Separate power supply for indoor units is required.)
Power supply
(A)
0.26
0.43
0.47
(kW)
0.056
0.092
0.102
Power factor
(%)
94
93
94
Starting current
(A)
0.60
0.80
1.10
Running current
Electrical
characteristics
Power consumption
Silky shade (1Y8.5/0.5)
Appearance
Outer
dimension
Height x Width x Depth
630 x 950 x 230
(mm)
Total weight
37
(kg)
40
Finned tube
Heat exchanger
Non-flammable insulation
Soundproof/Heat-insulating material
Centrifugal fan
Fan
Fan unit
Standard air flow
(High/Mid/Low)
Motor outlet
40
(m3/h)
480/420/360
900/780/650
1,080/930/780
45
(W)
70
Standard filter (Simple filter)
Air filter
Remote controller
Controller
Gas side
Connecting
Liquid side
pipe
O
/ 9.5
(mm)
(dB(A))
O
/ 15.9
O
/ 9.5
O
/ 6.4
(mm)
Drain port (Nominal dia. mm)
Sound pressure level (Note 2)
(High/Mid/Low)
O
/ 12.7
20 (Polyvinyl chloride tube)
39/37/35
45/41/38
49/44/39
Available
PMV Kit
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the
actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions
Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB
Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB/6oC WB
9-11 -1
60Hz
Specifications (60Hz)
Model name
Cooling/Heating capacity (Note 1)
MML-
AP0071H
AP0091H
AP0121H
AP0151H
AP0181H
AP0241H
(kW)
2.2/2.5
2.8/3.2
3.6/4.0
4.5/5.0
5.6/6.3
7.1/8.0
Power supply
1 phase 60Hz 220V (Separate power supply for indoor units is required.)
Running current
Electrical
characteristics
(A)
0.25
0.44
0.53
(kW)
0.053
0.092
0.113
Power factor
(%)
96
95
97
Starting current
(A)
0.60
0.80
1.10
Power consumption
Silky shade (1Y8.5/0.5)
Appearance
Outer
dimension
Height x Width x Depth
Total weight
(mm)
630 x 950 x 230
37
(kg)
40
Finned tube
Heat exchanger
Soundproof/Heat-insulating material
Non-flammable insulation
Fan
Fan unit
Centrifugal fan
Standard air flow
(High/Mid/Low)
Motor outlet
(m3/h)
480/420/360
900/780/650
45
(W)
Air filter
70
Standard filter (Simple filter)
Controller
Connecting
pipe
1,080/930/780
Remote controller
Gas side
(mm)
Liquid side
(mm)
Drain port
Sound pressure level (Note 2)
(High/Mid/Low)
O
/ 9.5
O
/ 12.7
O
/ 6.4
(Nominal dia. mm)
(dB(A))
O
/ 15.9
O
/ 9.5
20 (Polyvinyl chloride tube)
39/37/35
45/41/38
PMV Kit
49/44/39
Available
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in
the actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions
Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
O
O
O
9-11 -2
O
O
O
9-11-2. Dimension
MML-AP0071H, AP0091H, AP0121H, AP0151H, AP0181H, AP0241H
Lower refrigerant piping port
(50 X 100 knockout hole)
130
Fixing hole (Floor)
(2-O
/ 10)
Operation switch section
(Sold separately)
Fixing hole (Wall)
(Two off knockout holes O
/ 10-O/ 20)
Air discharge port
Hole fixing wall
(2-10 X 24 long hole)
Air suction port
( left100
side )
Refrigerant pipe port
(50 X 100 knockout
hole on both sides)
Earth screw
(M6)
Refrigerant pipe port
(O
/ 130 knockout hole)
Power supply cord hole
(O
/ 26 knockout on both sides)
Wired remote controller
RBC-AMT31E
Dimensions
A
B
AP0071H, AP0091H, AP0121H
O
/ 9.5
O
/ 6.4
AP0151H, AP0181H
O
/ 12.7
O
/ 6.4
AP0241H
O
/ 15.9
O
/ 9.5
Model MML-
Simple wired remote controller
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E2
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
Refrigerant pipe
connecting port
(Liquid side O
/ B)
Refrigerant pipe
connecting port
(Gas side O
/ A)
Drain pipe connecting port
(O
/ 20)
500
(Front side) or more
300
or more
1000 or more
Positional
Space required for service
Figure shows piping at the left side drawing of piping
Wall
Wall
(Front side)
Note: All dimensions are in mm.
9-11 -3
TR
CN066
(WHI)
1 1
2 2
RED
Closed-end
connector
WHI
Power supply
single phase
220-240V 50Hz
220V 60Hz
R(L) S(N)
Indoor unit
earth screw
1 1
3 3
WHI
CN067
(BLK)
RED
3 3
1 1
3 3
1 1
P301
(BLK)
FUSE
(YEL)
CN309
(GRY)
CN304
1 2
1 2
CN040
(BLU)
Outdoor unit
U1 U2
U1 U2
B
1 2
1 2
CN1
A
3 3
2
1 1
L
X Y
1 2
1 2
CN03(RED)
CN02
(BLU)
CN074 1
(WHI) 1
RY002
CN068
(BLU) 1
3
3
3
LM
1
1 2 3 4 5 6
1 2 3 4 5 6
Sub P.C. board
MCC-1520
1 2 3 4 5 6
1 2 3 4 5 6
1 2 3 4 5 6
1 2 3 4 5 6
PMV
1 2 3 4 5 6 CN082
1 2 3 4 5 6 (BLU)
TR
CN01
(WHI)
CN02
(YEL)
1 2 3 4 5 6
T10
CN061
(YEL)
1
2
3
4
5
CN081
(BLK)
OPTION
Symbol
FM
RC
TR
TA
TC1,TC2,TCJ
RY001
RY002
RY004
RY005~007
PMV
1 2 3 4 5 6
1 2
CN060
(WHI)
1
2
CN070
(WHI)
RED : RED
WHI : WHITE
YEL :YELLOW
BLU : BLUE
BLK : BLACK
GRY : GRAY
PNK : PINK
ORN :ORANGE
BRN : BROWN
GRN : GREEN
Color
indication
Parts name
Fan motor
Running capacitor
Transformer
Indoor temp sensor
Temp sensor
Louver control relay
Drain control relay
Heater control relay
Fan motor control relay
Pulse motor valve
FILTER
1
EXCT
2
TC1
TC2
TCJ
TA
CN073
(RED)
1
2 PNL
3
1 1
2 2
CN100
(BRN)
CN080
(GRN)
1 1
2 2
1 1
2 2
1 1
2 2
CN101
(BLK)
CN102
(RED)
CN104
(YEL)
FS
1
3 CN030
1 2 3 (RED)
FAN
DRIVE
CN032
(WHI)
Control P.C. board
for Indoor unit
MCC-1403
CN075
(WHI)
CN033
3 (GRN)
Power supply
circuit
RY001
DP
6 4 3 1 2 5
6 4 3 1 2 5
PMV
indicates the terminal block.
the letter inside indicates the terminal number.
2. A dotted line and broken line indicate
the wiring on site.
Indicates the control p.c. board.
3.
1.
MCC-1401
Network Adapter
(Option)
UL
CN01(WHI)
1 2
1 2
1 2 3 4 5
CN050
(WHI)
RY005
RY006
M
Remote Controller
1 2 3 RC
1
3
RY007
H
RED BLK ORN BLU YEL
FAN
7
5
3
1
CN083 9
(WHI) 9
7
5
3
1
CN041
(BLU)
RY004
T5.0A 250V~
Flow selector
unit earth
screw
Line Filter
AC IN
RC
BLU
2
3
4
5
6
BLU
2
3
4
5
6
BLK
9-11 -4
BLK
FM
9-11-3. Wiring diagram
Model: MML-AP0071H, AP0091H, AP0121H, AP0151H, AP0181H, AP0241H
9-11-4. Sensible capacity table
(MML-AP***H)
Cooling capacity
Unit
size
007
009
012
Outdoor
air temp.
˚CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
16.0˚CWB
23˚CDB
TC
SHC
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
1.9
1.2
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.4
1.4
3.2
2.0
3.2
2.0
3.2
2.0
3.2
2.0
3.2
2.0
3.2
2.0
3.2
2.0
3.2
2.0
3.2
2.0
3.2
2.0
3.2
2.0
3.2
2.0
3.2
2.0
3.2
2.0
3.1
1.9
3.1
1.9
18.0˚CWB
26˚CDB
TC
SHC
2.1
1.4
2.1
1.4
2.1
1.4
2.1
1.4
2.1
1.4
2.1
1.4
2.1
1.4
2.1
1.4
2.1
1.4
2.1
1.4
2.1
1.4
2.1
1.4
2.1
1.4
2.1
1.4
2.1
1.4
2.0
1.3
2.7
1.6
2.7
1.6
2.7
1.6
2.7
1.6
2.7
1.6
2.7
1.6
2.7
1.6
2.7
1.6
2.7
1.6
2.7
1.6
2.7
1.6
2.7
1.6
2.7
1.6
2.7
1.6
2.7
1.6
2.6
1.5
3.4
2.1
3.4
2.1
3.4
2.1
3.4
2.1
3.4
2.1
3.4
2.1
3.4
2.1
3.4
2.1
3.4
2.1
3.4
2.1
3.4
2.1
3.4
2.1
3.4
2.1
3.4
2.1
3.3
2.1
3.3
2.0
TC : Total Capacity (kW) SHC : Sensible Heat Capacity (kW)
Indoor air temp.
19.0˚CWB
20.0˚CWB
22.0˚CWB
24.0˚CWB
27˚CDB
28˚CDB
30˚CDB
32˚CDB
TC
SHC
TC
SHC
TC
SHC
TC
SHC
2.2
1.4
2.3
1.4
2.4
1.4
2.5
1.4
2.2
1.4
2.3
1.4
2.4
1.4
2.5
1.4
2.2
1.4
2.3
1.4
2.4
1.4
2.5
1.4
2.2
1.4
2.3
1.4
2.4
1.4
2.5
1.4
2.2
1.4
2.3
1.4
2.4
1.4
2.5
1.4
2.2
1.4
2.3
1.4
2.4
1.4
2.5
1.4
2.2
1.4
2.3
1.4
2.4
1.4
2.5
1.4
2.2
1.4
2.3
1.4
2.4
1.4
2.5
1.4
2.2
1.4
2.3
1.4
2.4
1.4
2.5
1.4
2.2
1.4
2.3
1.4
2.4
1.4
2.5
1.4
2.2
1.4
2.3
1.4
2.4
1.4
2.5
1.4
2.2
1.4
2.3
1.4
2.4
1.4
2.5
1.4
2.2
1.4
2.3
1.4
2.4
1.4
2.5
1.4
2.2
1.4
2.3
1.4
2.4
1.4
2.5
1.4
2.2
1.4
2.2
1.4
2.4
1.4
2.5
1.3
2.1
1.3
2.2
1.3
2.3
1.3
2.4
1.3
2.8
1.6
2.9
1.6
3.1
1.6
3.2
1.5
2.8
1.6
2.9
1.6
3.1
1.6
3.2
1.5
2.8
1.6
2.9
1.6
3.1
1.6
3.2
1.5
2.8
1.6
2.9
1.6
3.1
1.6
3.2
1.5
2.8
1.6
2.9
1.6
3.1
1.6
3.2
1.5
2.8
1.6
2.9
1.6
3.1
1.6
3.2
1.5
2.8
1.6
2.9
1.6
3.1
1.6
3.2
1.5
2.8
1.6
2.9
1.6
3.1
1.6
3.2
1.5
2.8
1.6
2.9
1.6
3.1
1.6
3.2
1.5
2.8
1.6
2.9
1.6
3.1
1.6
3.2
1.5
2.8
1.6
2.9
1.6
3.1
1.6
3.2
1.5
2.8
1.6
2.9
1.6
3.1
1.6
3.2
1.5
2.8
1.6
2.9
1.6
3.1
1.6
3.2
1.5
2.8
1.6
2.9
1.6
3.1
1.6
3.2
1.5
2.7
1.6
2.8
1.6
3.0
1.6
3.1
1.5
2.7
1.5
2.8
1.5
2.9
1.5
3.1
1.5
3.5
2.1
3.6
2.1
3.8
2.1
4.0
2.0
3.5
2.1
3.6
2.1
3.8
2.1
4.0
2.0
3.5
2.1
3.6
2.1
3.8
2.1
4.0
2.0
3.5
2.1
3.6
2.1
3.8
2.1
4.0
2.0
3.5
2.1
3.6
2.1
3.8
2.1
4.0
2.0
3.5
2.1
3.6
2.1
3.8
2.1
4.0
2.0
3.5
2.1
3.6
2.1
3.8
2.1
4.0
2.0
3.5
2.1
3.6
2.1
3.8
2.1
4.0
2.0
3.5
2.1
3.6
2.1
3.8
2.1
4.0
2.0
3.5
2.1
3.6
2.1
3.8
2.1
4.0
2.0
3.5
2.1
3.6
2.1
3.8
2.1
4.0
2.0
3.5
2.1
3.6
2.1
3.8
2.1
4.0
2.0
3.5
2.1
3.6
2.1
3.8
2.1
4.0
2.0
3.5
2.1
3.6
2.1
3.8
2.1
4.0
2.0
3.4
2.1
3.5
2.1
3.7
2.0
3.9
2.0
3.4
2.0
3.5
2.0
3.7
2.0
3.8
1.9
9-11 -5
Cooling capacity (cont.)
Unit
size
015
018
024
Outdoor
air temp.
˚CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
16.0˚CWB
23˚CDB
TC
SHC
4.1
2.6
4.1
2.6
4.1
2.6
4.1
2.6
4.1
2.6
4.1
2.6
4.1
2.6
4.1
2.6
4.1
2.6
4.1
2.6
4.1
2.6
4.1
2.6
4.1
2.6
4.1
2.6
4.0
2.6
3.9
2.5
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.0
3.2
4.9
3.1
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.3
4.2
6.2
4.0
18.0˚CWB
26˚CDB
TC
SHC
4.4
2.8
4.4
2.8
4.4
2.8
4.4
2.8
4.4
2.8
4.4
2.8
4.4
2.8
4.4
2.8
4.4
2.8
4.4
2.8
4.4
2.8
4.4
2.8
4.4
2.8
4.4
2.8
4.3
2.8
4.2
2.6
5.4
3.5
5.4
3.5
5.4
3.5
5.4
3.5
5.4
3.5
5.4
3.5
5.4
3.5
5.4
3.5
5.4
3.5
5.4
3.5
5.4
3.5
5.4
3.5
5.4
3.5
5.4
3.5
5.3
3.4
5.2
3.3
6.9
4.5
6.9
4.5
6.9
4.5
6.9
4.5
6.9
4.5
6.9
4.5
6.9
4.5
6.9
4.5
6.9
4.5
6.9
4.5
6.9
4.5
6.9
4.5
6.9
4.5
6.9
4.5
6.7
4.4
6.6
4.2
Indoor air temp.
19.0˚CWB
27˚CDB
TC
SHC
4.5
2.8
4.5
2.8
4.5
2.8
4.5
2.8
4.5
2.8
4.5
2.8
4.5
2.8
4.5
2.8
4.5
2.8
4.5
2.8
4.5
2.8
4.5
2.8
4.5
2.8
4.5
2.8
4.4
2.7
4.3
2.6
5.6
3.5
5.6
3.5
5.6
3.5
5.6
3.5
5.6
3.5
5.6
3.5
5.6
3.5
5.6
3.5
5.6
3.5
5.6
3.5
5.6
3.5
5.6
3.5
5.6
3.5
5.6
3.5
5.5
3.4
5.4
3.3
7.1
4.5
7.1
4.5
7.1
4.5
7.1
4.5
7.1
4.5
7.1
4.5
7.1
4.5
7.1
4.5
7.1
4.5
7.1
4.5
7.1
4.5
7.1
4.5
7.1
4.5
7.1
4.5
7.0
4.4
6.8
4.2
20.0˚CWB
28˚CDB
TC
SHC
4.6
2.8
4.6
2.8
4.6
2.8
4.6
2.8
4.6
2.8
4.6
2.8
4.6
2.8
4.6
2.8
4.6
2.8
4.6
2.8
4.6
2.8
4.6
2.8
4.6
2.8
4.6
2.8
4.5
2.7
4.4
2.6
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.7
3.4
5.5
3.3
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.2
4.4
7.0
4.2
9-11 -6
22.0˚CWB
30˚CDB
TC
SHC
4.9
2.8
4.9
2.8
4.9
2.8
4.9
2.8
4.9
2.8
4.9
2.8
4.9
2.8
4.9
2.8
4.9
2.8
4.9
2.8
4.9
2.8
4.9
2.8
4.9
2.8
4.9
2.8
4.8
2.7
4.7
2.6
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.0
3.4
5.9
3.3
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.6
4.4
7.4
4.2
24.0˚CWB
32˚CDB
TC
SHC
5.1
2.7
5.1
2.7
5.1
2.7
5.1
2.7
5.1
2.7
5.1
2.7
5.1
2.7
5.1
2.7
5.1
2.7
5.1
2.7
5.1
2.7
5.1
2.7
5.1
2.7
5.1
2.7
5.0
2.7
4.9
2.5
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.3
3.3
6.1
3.2
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
7.9
4.3
7.8
4.1
Heating capacity
Unit
size
007
009
012
Outdoor
air temp.
˚CWB
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
SHC
1.6
1.7
1.8
1.8
1.9
2.0
2.1
2.2
2.3
2.4
2.5
2.6
2.6
2.6
2.6
2.6
2.0
2.1
2.3
2.3
2.5
2.6
2.7
2.9
3.0
3.1
3.2
3.3
3.3
3.3
3.3
3.3
2.5
2.7
2.8
2.9
3.1
3.3
3.4
3.6
3.7
3.9
4.0
4.2
4.2
4.2
4.2
4.2
SHC : Sensible Heat Capacity (kW)
Indoor air temp. ˚CDB
18.0
20.0
22.0
24.0
SHC
SHC
SHC
SHC
1.5
1.5
1.5
1.4
1.6
1.6
1.6
1.5
1.7
1.7
1.7
1.6
1.8
1.8
1.7
1.7
1.9
1.9
1.8
1.8
2.0
2.0
1.9
1.9
2.1
2.0
2.0
1.9
2.2
2.1
2.1
2.0
2.3
2.2
2.2
2.1
2.4
2.3
2.3
2.2
2.5
2.4
2.4
2.3
2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.0
1.9
1.9
1.8
2.1
2.1
2.0
1.9
2.2
2.2
2.1
2.1
2.3
2.2
2.2
2.1
2.4
2.4
2.3
2.3
2.6
2.5
2.4
2.4
2.7
2.6
2.6
2.5
2.8
2.7
2.7
2.6
2.9
2.9
2.8
2.7
3.0
3.0
2.9
2.8
3.2
3.1
3.0
2.9
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
2.5
2.4
2.3
2.3
2.6
2.6
2.5
2.4
2.8
2.7
2.7
2.6
2.9
2.8
2.7
2.7
3.0
3.0
2.9
2.8
3.2
3.1
3.0
3.0
3.3
3.3
3.2
3.1
3.5
3.4
3.3
3.3
3.7
3.6
3.5
3.4
3.8
3.7
3.6
3.5
3.9
3.9
3.8
3.7
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
9-11 -7
Heating capacity (cont.)
Unit
size
015
018
024
Outdoor
air temp.
˚CWB
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
SHC
3.1
3.3
3.6
3.7
3.9
4.1
4.3
4.5
4.7
4.8
5.0
5.2
5.2
5.2
5.2
5.2
3.9
4.2
4.5
4.6
4.9
5.1
5.4
5.6
5.9
6.1
6.3
6.6
6.6
6.6
6.6
6.6
5.0
5.3
5.7
5.8
6.2
6.5
6.8
7.1
7.4
7.7
8.0
8.3
8.3
8.3
8.3
8.3
Indoor air temp. ˚CDB
18.0
20.0
22.0
SHC
SHC
SHC
3.1
3.0
2.9
3.3
3.2
3.1
3.5
3.4
3.3
3.6
3.5
3.4
3.8
3.7
3.6
4.0
3.9
3.8
4.2
4.1
4.0
4.4
4.3
4.2
4.6
4.5
4.4
4.7
4.6
4.5
4.9
4.8
4.7
5.1
5.0
4.9
5.1
5.0
4.9
5.1
5.0
4.9
5.1
5.0
4.9
5.1
5.0
4.9
3.9
3.8
3.7
4.1
4.0
3.9
4.4
4.3
4.2
4.5
4.4
4.3
4.8
4.7
4.6
5.0
4.9
4.8
5.3
5.2
5.0
5.5
5.4
5.3
5.8
5.6
5.5
6.0
5.9
5.7
6.2
6.1
5.9
6.4
6.3
6.1
6.4
6.3
6.1
6.4
6.3
6.1
6.4
6.3
6.1
6.4
6.3
6.1
4.9
4.8
4.7
5.2
5.1
5.0
5.6
5.5
5.3
5.7
5.6
5.5
6.1
5.9
5.8
6.4
6.2
6.1
6.7
6.6
6.4
7.0
6.9
6.7
7.3
7.1
7.0
7.6
7.4
7.3
7.9
7.7
7.5
8.2
8.0
7.8
8.2
8.0
7.8
8.2
8.0
7.8
8.2
8.0
7.8
8.2
8.0
7.8
24.0
SHC
2.9
3.0
3.2
3.3
3.5
3.7
3.9
4.1
4.2
4.4
4.6
4.8
4.8
4.8
4.8
4.8
3.6
3.8
4.1
4.2
4.4
4.7
4.9
5.1
5.3
5.6
5.8
6.0
6.0
6.0
6.0
6.0
4.6
4.9
5.2
5.3
5.6
5.9
6.2
6.5
6.8
7.1
7.3
7.6
7.6
7.6
7.6
7.6
9-11 -8
9-11-5. Air throw distance chart
High wind
2
Med. wind
Low wind
1
0
1
2
3
4
5
6
Distance from discharge grille (m)
7
3
High wind
Med. wind
Low wind
2
1
0
1
2
3
4
MML-AP0181H, AP0241H
Air speed (m/s)
3
MML-AP0121H, AP0151H
Air speed (m/s)
Air speed (m/s)
MML-AP0071H, AP0091H
5
6
7
Distance from discharge grille (m)
4
High wind
3
Med. wind
2
Low wind
1
0
1
2
3
4
5
6
7
Distance from discharge grille (m)
9-11 -9
8
9-11-6. Sound characteristics (NC-Curve)
[Measuring location]
Microphon
Air outlet
1m
1m
MML-AP0071H,MML-AP0091H
Fan tap
H
39
L
Fan tap
H
M
L
35
Sound pressure
level (dB(A))
45
41
38
M
37
90
90
80
80
70
NC- 7 0
60
NC- 6 0
50
NC- 5 0
40
NC- 4 0
H
30
M
Oct ave band sound pressure level (dB)
Oct ave band sound pressure level (dB)
Sound pressure
level (dB(A))
MML-AP0121H,MML-AP0151H
NC- 3 0
L
20
NC- 7 0
60
NC- 6 0
50
NC- 5 0
H
M
30
NC- 3 0
L
Approximate threshold of
hearing for continuous noise
NC- 2 0
10
10
63
125
250
500
1000 2000 4000
Octave band center frequency (Hz)
8000
MML-AP0181H,MML-AP0241H
Fan tap
H
M
L
Sound pressure
level (dB(A))
49
44
39
90
80
Oct ave band sound pressure level (dB)
NC- 4 0
40
20
NC- 2 0
Approximate threshold of
hearing for continuous noise
70
70
NC- 7 0
60
NC- 6 0
50
NC- 5 0
H
40
NC- 4 0
M
L
30
20
Approximate threshold of
hearing for continuous noise
NC- 3 0
NC- 2 0
10
63
125
250
500
1000 2000 4000
Octave band center frequency (Hz)
8000
9-11 -10
63
125
250
500
1000 2000 4000
Octave band center frequency (Hz)
8000
9-11-7. Accessories
Apperarance
Standard accessories
Part name
Qty
Installation
Manual
1
Heat
insulation
2
Shape
Use
Part name
Bushing
Qty
1
For insulating the indoor unit
pipe connections
Optional accessories
Remote controller
Model Name
Wired remote controller
RBC-AMT31E
Simple wired remote controller
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E2
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
Central remote controller
TCB-SC642TLE2
ON-OFF controller
TCB-CC163TLE2
9-11 -11
Shape
Use
For installation in the wire
knockout
9-12-1. Specifications
50Hz
Specifications (50Hz)
Model name
Cooling/Heating capacity (Note 1)
MML-
AP0071BH
AP0091BH
AP0121BH
AP0151BH
AP0181BH
AP0241BH
(kW)
2.2/2.5
2.8/3.2
3.6/4.0
4.5/5.0
5.6/6.3
7.1/8.0
Power supply
1 phase 50Hz 230V (220-240V) (Separate power supply for indoor units is required.)
(A)
0.25
0.45
0.46
(kW)
0.056
0.090
0.095
Power factor
(%)
97
87
90
Starting current
(A)
0.60
0.80
1.00
Running current
Electrical
characteristics
Power consumption
Zinc hot dipping steel plate
Appearance
Outer
dimension
Height x Width x Depth
Total weight
(mm)
600 x 745 x 220
600 x 1,045 x 220
(kg)
21
29
Finned tube
Heat exchanger
Non-flammable insulation
Soundproof/Heat-insulating material
Centrifugal fan
Fan
Standard air flow
(High/Mid/Low)
(m3/h)
460/400/300
740/600/490
950/790/640
Fan unit
Motor
(W)
19
70
Static pressure range (kPa)
0
Air filter
Standard filter (Simple filter)
Controller
Remote controller
Gas side
Connecting
Liquid side
pipe
(mm)
(mm)
Drain port (Nominal dia. mm)
Sound pressure level (Note 2)
(High/Mid/Low)
(dB(A))
O
/ 9.5
O
/ 12.7
O
/ 6.4
O
/ 15.9
O
/ 9.5
20 (Polyvinyl chloride tube)
36/34/32
PMV Kit
42/37/33
Not available
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the
actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions
Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB
Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB/6oC WB
9-12 -1
60Hz
Specifications (60Hz)
Model name
Cooling/Heating capacity (Note 1)
MML-
AP0071BH
AP0091BH
AP0121BH
AP0151BH
AP0181BH
AP0241BH
(kW)
2.2/2.5
2.8/3.2
3.6/4.0
4.5/5.0
5.6/6.3
7.1/8.0
Power supply
1 phase 60Hz 220V (Separate power supply for indoor units is required.)
Running current
(A)
0.27
0.46
0.51
(kW)
0.058
0.096
0.110
Power factor
(%)
98
95
98
Starting current
(A)
0.60
0.80
1.00
Power consumption
Electrical
characteristics
Appearance
Zinc hot dipping steel plate
Outer
dimension
Height x Width x
Depth
Total weight
(mm)
600 x 745 x 220
600 x 1,045 x 220
(kg)
21
29
Finned tube
Heat exchanger
Non-flammable insulation
Soundproof/Heat-insulating material
Fan
Fan unit
Centrifugal fan
Standard air flow
(High/Mid/Low)
Motor
(m3/h)
460/400/300
(W)
Static pressure range
19
70
(kPa)
0
Standard filter (Simple filter)
Air filter
Remote controller
Controller
Connecting
pipe
950/790/640
740/600/490
Gas side
(mm)
Liquid side
(mm)
Drain port
O
/ 9.5
O
/ 12.7
O
/ 6.4
(Nominal dia. mm)
Sound pressure level (Note 2) (High/Mid/Low)
O
/ 15.9
O
/ 9.5
20 (Polyvinyl chloride tube)
(dB(A))
36/34/32
42/37/33
Not available
PMV Kit
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in
the actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions
Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
O
O
9-12
O
O
O
O
-2 (Revised Edition in 7.Apr.2006)
9-12-2. Dimension
MML-AP0071BH, AP0091BH, AP0121BH, AP0151BH, AP0181BH, AP0241BH
Fixing hole (Floor)
(Discharge port size in flange)
Ceiling board section
150
or more
(Service space)
150
or more
(Air discharge port size in flange)
(Service space)
2-O
/ 4.7 hole
(Left/right side each)
Expansion
valve box
G-O
/ 4.7 hole
(Front side and rear side each)
4-O
/ 15 hole
(For mounting rear side)
2-12 5 18 hole
Fixing hole (Floor)
Name
No.
1
Pipe connecting port at liquid side (O
/ E)
2
Pipe connecting port at gas side (O
/ F)
3
Drain pipe connecting port (20A)
5
Air filter
B
C
AP0151BH, AP0181BH
910 880 850
AP0241BH
D
E
4
6.4
7
9.5
F
G
9.5
5
12.7
15.9
8
Wired remote controller
RBC-AMT31E4
Simple wired remote controller
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E2
120
Electric parts box
(Earth terminal on the inside)
A
Model MML-
AP0071BH, AP0091BH, AP0121BH 610 580 550
2.7
4
Dimensions
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
120
16
Note: All dimensions are in mm.
9-12 -3
9-12 -4
WHI
RC
B
Outdoor unit
1 2
1 2
CN1
Remote Controller
A
X
Y
MCC-1401
CN03(RED)
CN02
(BLU)
1 1
2 2
CN03
(RED)
CN041
(BLU)
1 2 3
1
3
1 2
1 2
RY007
H
indicates the terminal block.
the letter inside indicates the terminal number.
2. A dotted line and broken line indicate
the wiring on site.
3.
Indicates the control p.c. board.
1.
3 3
2
1 1
2
4
5
6
3
L
UL
CN074 1
(WHI) 1
RY002
RED : RED
WHI : WHITE
YEL :YELLOW
BLU : BLUE
BLK : BLACK
GRY : GRAY
PNK : PINK
ORN :ORANGE
BRN : BROWN
GRN : GREEN
Color
indication
1 2 3 4 5
CN050
(WHI)
RY005
RY006
M
RED BLK ORN BLU YEL
FAN
7
5
3
1 CN068 1
CN083 9
(WHI) 9
(BLU) 1
7
5
3
1
2
4
5
6
3
CN040
(BLU)
CN044
(BRW)
1
2
EMG
CN066
(WHI)
(BLK)
CN067
T5.0A 250V~
FUSE
(YEL)
CN309
(GRY)
CN304
RY004
RC
1
2
3 3
3 3
AC IN
1 1
1 1
3
1
RED
FM
R301
(BLK)
GRN
Network
adapter
(Option)
CN01(WHI)
1 2
1 2
RED BLK ORN BLU YEL
FAN
7
5
3
1
CN083 9
(WHI) 9
7
5
3
1
WHI
RED
WHI
FM
1
3
2
4
5
6
For AP0071BH,AP0091BH,AP0121BH
U1 U2
1 2
1 2
GRN
U1 U2
TR
Closed-end
connector
Flow selector
unit earth
screw
RED
R(L) S(N)
RED
Power supply
single phase
220-240V 50Hz
220V 60Hz
Indoor unit
earth screw
WHI
1
3
2
4
5
6
3
3
3
3
CN082
(BLU) CN104
(YEL)
CN030
(RED)
1 2 3 4 5 6 CN02
1 2 3 4 5 6 (YEL)
Symbol
FM
RC
TR
TA
TC1,TC2,TCJ
RY001
RY002
RY004
RY005~007
PMV
TR
1 2 3 4 5 6 CN01
1 2 3 4 5 6 (WHI)
Sub P.C. board
MCC-1520
CN061
(YEL)
1 2 3 4 5 6
CN075
(WHI)
1 2 3 4 5 6
1 2 3 4 5 6
1
2
3
4
5
Parts name
Fan motor
Running capacitor
Transformer
Indoor temp sensor
Temp sensor
Louver control relay
Drain control relay
Heater control relay
Fan motor control relay
Pulse motor valve
OPTION
FAN
DRIVE
CN060
(WHI)
1 2 3 4 5 6
1 2
CN032
(WHI)
CN081
(BLK)
FILTER
1
2
CN070
(WHI)
TC2
TCJ
TA
1
EXCT
2
1
2 PNL
3
1 1
2
3 3
1 1
2 2
1 1
2 2
1 1
2 2
CN073
(RED)
CN080
(GRN)
CN100
(BRW)
CN101
(BLK)
CN102
(RED)
1 2 3 4 5 6
1 2 3 4 5 6 PMV
1
3
1 2 3
Control P.C. board
for undoor unit
MCC-1403
3 CN033
3 (GRN)
Power supply
circuit
RY001
1
1
6 4 3 1 2 5
6 4 3 1 2 5
PMV
TC1
9-12-3. Wiring diagram
Model: MML-AP0071BH, AP0091BH, AP0121BH, AP0151BH, AP0181BH, AP0241BH
9-12-4. Sensible capacity table
(MML-AP***BH)
Cooling capacity
Unit
size
007
009
012
Outdoor
air temp.
˚CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
16.0˚CWB
23˚CDB
TC
SHC
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
2.0
1.3
1.9
1.2
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.4
1.4
3.3
2.1
3.3
2.1
3.3
2.1
3.3
2.1
3.3
2.1
3.3
2.1
3.3
2.1
3.3
2.1
3.3
2.1
3.3
2.1
3.3
2.1
3.3
2.1
3.3
2.1
3.3
2.1
3.2
2.0
3.1
2.0
18.0˚CWB
26˚CDB
TC
SHC
2.1
1.4
2.1
1.4
2.1
1.4
2.1
1.4
2.1
1.4
2.1
1.4
2.1
1.4
2.1
1.4
2.1
1.4
2.1
1.4
2.1
1.4
2.1
1.4
2.1
1.4
2.1
1.4
2.1
1.4
2.0
1.3
2.7
1.6
2.7
1.6
2.7
1.6
2.7
1.6
2.7
1.6
2.7
1.6
2.7
1.6
2.7
1.6
2.7
1.6
2.7
1.6
2.7
1.6
2.7
1.6
2.7
1.6
2.7
1.6
2.7
1.6
2.6
1.5
3.5
2.2
3.5
2.2
3.5
2.2
3.5
2.2
3.5
2.2
3.5
2.2
3.5
2.2
3.5
2.2
3.5
2.2
3.5
2.2
3.5
2.2
3.5
2.2
3.5
2.2
3.5
2.2
3.4
2.2
3.4
2.1
TC : Total Capacity (kW) SHC : Sensible Heat Capacity (kW)
Indoor air temp.
19.0˚CWB
20.0˚CWB
22.0˚CWB
24.0˚CWB
27˚CDB
28˚CDB
30˚CDB
32˚CDB
TC
SHC
TC
SHC
TC
SHC
TC
SHC
2.2
1.4
2.3
1.4
2.4
1.4
2.5
1.4
2.2
1.4
2.3
1.4
2.4
1.4
2.5
1.4
2.2
1.4
2.3
1.4
2.4
1.4
2.5
1.4
2.2
1.4
2.3
1.4
2.4
1.4
2.5
1.4
2.2
1.4
2.3
1.4
2.4
1.4
2.5
1.4
2.2
1.4
2.3
1.4
2.4
1.4
2.5
1.4
2.2
1.4
2.3
1.4
2.4
1.4
2.5
1.4
2.2
1.4
2.3
1.4
2.4
1.4
2.5
1.4
2.2
1.4
2.3
1.4
2.4
1.4
2.5
1.4
2.2
1.4
2.3
1.4
2.4
1.4
2.5
1.4
2.2
1.4
2.3
1.4
2.4
1.4
2.5
1.4
2.2
1.4
2.3
1.4
2.4
1.4
2.5
1.4
2.2
1.4
2.3
1.4
2.4
1.4
2.5
1.4
2.2
1.4
2.3
1.4
2.4
1.4
2.5
1.4
2.2
1.4
2.2
1.4
2.4
1.4
2.5
1.3
2.1
1.3
2.2
1.3
2.3
1.3
2.4
1.3
2.8
1.6
2.9
1.6
3.1
1.6
3.2
1.5
2.8
1.6
2.9
1.6
3.1
1.6
3.2
1.5
2.8
1.6
2.9
1.6
3.1
1.6
3.2
1.5
2.8
1.6
2.9
1.6
3.1
1.6
3.2
1.5
2.8
1.6
2.9
1.6
3.1
1.6
3.2
1.5
2.8
1.6
2.9
1.6
3.1
1.6
3.2
1.5
2.8
1.6
2.9
1.6
3.1
1.6
3.2
1.5
2.8
1.6
2.9
1.6
3.1
1.6
3.2
1.5
2.8
1.6
2.9
1.6
3.1
1.6
3.2
1.5
2.8
1.6
2.9
1.6
3.1
1.6
3.2
1.5
2.8
1.6
2.9
1.6
3.1
1.6
3.2
1.5
2.8
1.6
2.9
1.6
3.1
1.6
3.2
1.5
2.8
1.6
2.9
1.6
3.1
1.6
3.2
1.5
2.8
1.6
2.9
1.6
3.1
1.6
3.2
1.5
2.7
1.6
2.8
1.6
3.0
1.6
3.1
1.5
2.7
1.5
2.8
1.5
2.9
1.5
3.1
1.5
3.6
2.2
3.7
2.2
3.9
2.2
4.1
2.1
3.6
2.2
3.7
2.2
3.9
2.2
4.1
2.1
3.6
2.2
3.7
2.2
3.9
2.2
4.1
2.1
3.6
2.2
3.7
2.2
3.9
2.2
4.1
2.1
3.6
2.2
3.7
2.2
3.9
2.2
4.1
2.1
3.6
2.2
3.7
2.2
3.9
2.2
4.1
2.1
3.6
2.2
3.7
2.2
3.9
2.2
4.1
2.1
3.6
2.2
3.7
2.2
3.9
2.2
4.1
2.1
3.6
2.2
3.7
2.2
3.9
2.2
4.1
2.1
3.6
2.2
3.7
2.2
3.9
2.2
4.1
2.1
3.6
2.2
3.7
2.2
3.9
2.2
4.1
2.1
3.6
2.2
3.7
2.2
3.9
2.2
4.1
2.1
3.6
2.2
3.7
2.2
3.9
2.2
4.1
2.1
3.6
2.2
3.7
2.2
3.9
2.2
4.1
2.1
3.5
2.2
3.6
2.2
3.8
2.1
4.0
2.1
3.5
2.1
3.6
2.1
3.8
2.1
3.9
2.0
9-12 -5
Cooling capacity (cont.)
Unit
size
015
018
024
Outdoor
air temp.
˚CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
16.0˚CWB
23˚CDB
TC
SHC
4.1
2.6
4.1
2.6
4.1
2.6
4.1
2.6
4.1
2.6
4.1
2.6
4.1
2.6
4.1
2.6
4.1
2.6
4.1
2.6
4.1
2.6
4.1
2.6
4.1
2.6
4.1
2.6
4.0
2.6
3.9
2.5
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.1
3.3
5.0
3.2
4.9
3.1
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.4
4.2
6.3
4.2
6.2
4.0
18.0˚CWB
26˚CDB
TC
SHC
4.4
2.8
4.4
2.8
4.4
2.8
4.4
2.8
4.4
2.8
4.4
2.8
4.4
2.8
4.4
2.8
4.4
2.8
4.4
2.8
4.4
2.8
4.4
2.8
4.4
2.8
4.4
2.8
4.3
2.8
4.2
2.6
5.4
3.5
5.4
3.5
5.4
3.5
5.4
3.5
5.4
3.5
5.4
3.5
5.4
3.5
5.4
3.5
5.4
3.5
5.4
3.5
5.4
3.5
5.4
3.5
5.4
3.5
5.4
3.5
5.3
3.4
5.2
3.3
6.9
4.5
6.9
4.5
6.9
4.5
6.9
4.5
6.9
4.5
6.9
4.5
6.9
4.5
6.9
4.5
6.9
4.5
6.9
4.5
6.9
4.5
6.9
4.5
6.9
4.5
6.9
4.5
6.7
4.4
6.6
4.2
Indoor air temp.
19.0˚CWB
27˚CDB
TC
SHC
4.5
2.8
4.5
2.8
4.5
2.8
4.5
2.8
4.5
2.8
4.5
2.8
4.5
2.8
4.5
2.8
4.5
2.8
4.5
2.8
4.5
2.8
4.5
2.8
4.5
2.8
4.5
2.8
4.4
2.7
4.3
2.6
5.6
3.5
5.6
3.5
5.6
3.5
5.6
3.5
5.6
3.5
5.6
3.5
5.6
3.5
5.6
3.5
5.6
3.5
5.6
3.5
5.6
3.5
5.6
3.5
5.6
3.5
5.6
3.5
5.5
3.4
5.4
3.3
7.1
4.5
7.1
4.5
7.1
4.5
7.1
4.5
7.1
4.5
7.1
4.5
7.1
4.5
7.1
4.5
7.1
4.5
7.1
4.5
7.1
4.5
7.1
4.5
7.1
4.5
7.1
4.5
7.0
4.4
6.8
4.2
20.0˚CWB
28˚CDB
TC
SHC
4.6
2.8
4.6
2.8
4.6
2.8
4.6
2.8
4.6
2.8
4.6
2.8
4.6
2.8
4.6
2.8
4.6
2.8
4.6
2.8
4.6
2.8
4.6
2.8
4.6
2.8
4.6
2.8
4.5
2.7
4.4
2.6
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.8
3.5
5.7
3.4
5.5
3.3
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.3
4.5
7.2
4.4
7.0
4.2
9-12 -6
22.0˚CWB
30˚CDB
TC
SHC
4.9
2.8
4.9
2.8
4.9
2.8
4.9
2.8
4.9
2.8
4.9
2.8
4.9
2.8
4.9
2.8
4.9
2.8
4.9
2.8
4.9
2.8
4.9
2.8
4.9
2.8
4.9
2.8
4.8
2.7
4.7
2.6
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.1
3.5
6.0
3.4
5.9
3.3
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.7
4.5
7.6
4.4
7.4
4.2
24.0˚CWB
32˚CDB
TC
SHC
5.1
2.7
5.1
2.7
5.1
2.7
5.1
2.7
5.1
2.7
5.1
2.7
5.1
2.7
5.1
2.7
5.1
2.7
5.1
2.7
5.1
2.7
5.1
2.7
5.1
2.7
5.1
2.7
5.0
2.7
4.9
2.5
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.4
3.4
6.3
3.3
6.1
3.2
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
8.1
4.4
7.9
4.3
7.8
4.1
Heating capacity
Unit
size
007
009
012
Outdoor
air temp.
˚CWB
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
SHC
1.6
1.7
1.8
1.8
1.9
2.0
2.1
2.2
2.3
2.4
2.5
2.6
2.6
2.6
2.6
2.6
2.0
2.1
2.3
2.3
2.5
2.6
2.7
2.9
3.0
3.1
3.2
3.3
3.3
3.3
3.3
3.3
2.5
2.7
2.8
2.9
3.1
3.3
3.4
3.6
3.7
3.9
4.0
4.2
4.2
4.2
4.2
4.2
SHC : Sensible Heat Capacity (kW)
Indoor air temp. ˚CDB
18.0
20.0
22.0
24.0
SHC
SHC
SHC
SHC
1.5
1.5
1.5
1.4
1.6
1.6
1.6
1.5
1.7
1.7
1.7
1.6
1.8
1.8
1.7
1.7
1.9
1.9
1.8
1.8
2.0
2.0
1.9
1.9
2.1
2.0
2.0
1.9
2.2
2.1
2.1
2.0
2.3
2.2
2.2
2.1
2.4
2.3
2.3
2.2
2.5
2.4
2.4
2.3
2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.6
2.5
2.4
2.4
2.0
1.9
1.9
1.8
2.1
2.1
2.0
1.9
2.2
2.2
2.1
2.1
2.3
2.2
2.2
2.1
2.4
2.4
2.3
2.3
2.6
2.5
2.4
2.4
2.7
2.6
2.6
2.5
2.8
2.7
2.7
2.6
2.9
2.9
2.8
2.7
3.0
3.0
2.9
2.8
3.2
3.1
3.0
2.9
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
3.3
3.2
3.1
3.0
2.5
2.4
2.3
2.3
2.6
2.6
2.5
2.4
2.8
2.7
2.7
2.6
2.9
2.8
2.7
2.7
3.0
3.0
2.9
2.8
3.2
3.1
3.0
3.0
3.3
3.3
3.2
3.1
3.5
3.4
3.3
3.3
3.7
3.6
3.5
3.4
3.8
3.7
3.6
3.5
3.9
3.9
3.8
3.7
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
4.1
4.0
3.9
3.8
9-12 -7
Heating capacity (cont.)
Unit
size
015
018
024
Outdoor
air temp.
˚CWB
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
SHC
3.1
3.3
3.6
3.7
3.9
4.1
4.3
4.5
4.7
4.8
5.0
5.2
5.2
5.2
5.2
5.2
3.9
4.2
4.5
4.6
4.9
5.1
5.4
5.6
5.9
6.1
6.3
6.6
6.6
6.6
6.6
6.6
5.0
5.3
5.7
5.8
6.2
6.5
6.8
7.1
7.4
7.7
8.0
8.3
8.3
8.3
8.3
8.3
Indoor air temp. ˚CDB
18.0
20.0
22.0
SHC
SHC
SHC
3.1
3.0
2.9
3.3
3.2
3.1
3.5
3.4
3.3
3.6
3.5
3.4
3.8
3.7
3.6
4.0
3.9
3.8
4.2
4.1
4.0
4.4
4.3
4.2
4.6
4.5
4.4
4.7
4.6
4.5
4.9
4.8
4.7
5.1
5.0
4.9
5.1
5.0
4.9
5.1
5.0
4.9
5.1
5.0
4.9
5.1
5.0
4.9
3.9
3.8
3.7
4.1
4.0
3.9
4.4
4.3
4.2
4.5
4.4
4.3
4.8
4.7
4.6
5.0
4.9
4.8
5.3
5.2
5.0
5.5
5.4
5.3
5.8
5.6
5.5
6.0
5.9
5.7
6.2
6.1
5.9
6.4
6.3
6.1
6.4
6.3
6.1
6.4
6.3
6.1
6.4
6.3
6.1
6.4
6.3
6.1
4.9
4.8
4.7
5.2
5.1
5.0
5.6
5.5
5.3
5.7
5.6
5.5
6.1
5.9
5.8
6.4
6.2
6.1
6.7
6.6
6.4
7.0
6.9
6.7
7.3
7.1
7.0
7.6
7.4
7.3
7.9
7.7
7.5
8.2
8.0
7.8
8.2
8.0
7.8
8.2
8.0
7.8
8.2
8.0
7.8
8.2
8.0
7.8
24.0
SHC
2.9
3.0
3.2
3.3
3.5
3.7
3.9
4.1
4.2
4.4
4.6
4.8
4.8
4.8
4.8
4.8
3.6
3.8
4.1
4.2
4.4
4.7
4.9
5.1
5.3
5.6
5.8
6.0
6.0
6.0
6.0
6.0
4.6
4.9
5.2
5.3
5.6
5.9
6.2
6.5
6.8
7.1
7.3
7.6
7.6
7.6
7.6
7.6
9-12 -8
9-12-5. Sound characteristics (NC-Curve)
Sound level values shown are based on a measurement in a non resound room.
Microphone
MML-AP0071BH, AP0091BH, AP0121BH
50Hz
H
M
L
60Hz
Fan Tap
M
L
A
36.0
34.0
32.0
Overall level
A
36.0
34.0
32.0
(dB)
C
41.7
40.2
37.9
(dB)
C
41.6
39.8
38.1
(standard sound pressure 0.0002 µbar)
Audibility limits
of continuous white level
(standard sound pressure 0.0002 µbar)
Audibility limits
of continuous white level
Octave band center frequency (Hz)
Octave band center frequency (Hz)
MML-AP0151BH, AP0181BH
Fan Tap
50Hz
H
M
L
60Hz
Fan Tap
H
M
L
Overall level
A
36.0
34.0
32.0
Overall level
A
36.0
34.0
32.0
(dB)
C
41.4
40.0
38.8
(dB)
C
41.4
40.0
39.0
(standard sound pressure 0.0002 µbar)
Audibility limits
of continuous white level
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
H
Overall level
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
Fan Tap
(standard sound pressure 0.0002 µbar)
Audibility limits
of continuous white level
Octave band center frequency (Hz)
Octave band center frequency (Hz)
9-12 -9
MML-AP0241BH
Fan Tap
50Hz
H
M
L
60Hz
Fan Tap
M
L
Overall level
A
42.0
37.0
33.0
Overall level
A
42.0
37.0
33.0
(dB)
C
46.4
41.0
37.7
(dB)
C
46.6
41.0
38.0
(standard sound pressure 0.0002 µbar)
Audibility limits
of continuous white level
(standard sound pressure 0.0002 µbar)
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
H
Octave band center frequency (Hz)
Audibility limits
of continuous white level
Octave band center frequency (Hz)
9-12 -10
9-12-6. Accessories
Apperarance
Standard accessories
Part name
Qty
Shape
Use
Part name
Qty
Shape
Use
Drain
receiver
fixing screw
1
For fix the drain receiver
Installation
Manual
1
Heat
insulation
2
For heat insulating the indoor
unit pipe connections
Drain hose
1
For water draining
(Attaches to the drain
receiver.)
Drain pan
1
For water draining
Heat
insulated
pipe
1
For insulating the drain
receiver
(Attaches to the drain
receiver.)
Drain filter
1
Drain filter
(inside the drain receiver)
Optional accessories
Remote controller
Model Name
Wired remote controller
RBC-AMT31E
Simple wired remote controller
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E2
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
Central remote controller
TCB-SC642TLE2
ON-OFF controller
TCB-CC163TLE2
9-12 -11
9-13-1. Specifications
50Hz
Specifications (50Hz)
Model name
MMF-
AP0151H
AP0181H
AP0241H
AP0271H
AP0361H
AP0481H
(kW)
4.5/5.0
5.6/6.3
7.1/8.0
8.0/9.0
11.2/12.5
14.0/16.0
Cooling/Heating capacity (Note 1)
Power supply
1 phase 50Hz 230V (220-240V) (Separate power supply for indoor units is required.)
Running current
Electrical
characteristics
(A)
0.67
0.88
1.29
1.60
(kW)
0.150
0.190
0.280
0.350
Power factor
(%)
97
Starting current
(A)
0.90
Power consumption
1.10
Height x Width x Depth
1,750 x 600 x 210
(mm)
Total weight
(kg)
48
Non-flammable insulation
Centrifugal fan
Fan
Motor
65
Finned tube
Soundproof/Heat-insulating material
Standard air flow
(High/Mid/Low)
1,750 x 600 x 390
49
Heat exchanger
Fan unit
2.10
1.70
W : Silky shade (1Y 8.5/0.5)
Appearance
Outer
dimension
95
94
(m3/h)
(W)
900/780/660
1,200/1,020/840
1,920/
1,680/
1,380
2,160/
1,860/
1,560
37
63
110
160
51/48/44
54/50/46
Standard filter (Simple filter)
Air filter
Remote controller
Controller
Gas side
Connecting
Liquid side
pipe
(mm)
O
/ 12.7
O
/ 15.9
(mm)
O
/ 6.4
O
/ 9.5
Drain port (Nominal dia. mm)
Sound pressure level (Note 2)
(High/Mid/Low)
(dB(A))
20 (Polyvinyl chloride tube)
46/43/38
49/45/40
Not available
PMV Kit
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the
actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions
Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB
Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB/6oC WB
9-13 -1
60Hz
Specifications (60Hz)
Model name
Cooling/Heating capacity (Note 1)
MMF-
AP0151H
AP0181H
AP0241H
AP0271H
AP0361H
AP0481H
(kW)
4.5/5.0
5.6/6.3
7.1/8.0
8.0/9.0
11.2/12.5
14.0/16.0
Power supply
Running current
Electrical
characteristics
1 phase 60Hz 220V (Separate power supply for indoor units is required.)
(A)
0.67
0.90
1.37
1.75
(kW)
0.146
0.195
0.295
0.380
Power factor
(%)
99
Starting current
(A)
0.90
Power consumption
1.10
1.80
Height x Width x
Depth
(mm)
(kg)
Total weight
1,750 x 600 x 390
1,750 x 600 x 210
48
65
49
Heat exchanger
Finned tube
Soundproof/Heat-insulating material
Non-flammable insulation
Fan
Centrifugal fan
Fan unit
Standard air flow
(High/Mid/Low)
(m3/h)
(W)
Motor
900/780/660
1,200/1,020/840
37
63
Air filter
1,920/1,680/1,380 2,160/1,860/1,560
110
160
51/48/44
54/50/46
Standard filter (Simple filter)
Controller
Connecting
pipe
2.30
W : Silky Shade (1Y 8.5/0.5)
Appearance
Outer
dimension
99
98
Remote controller
Gas side
(mm)
O
/ 12.7
O
/ 15.9
Liquid side
(mm)
O
/ 6.4
O
/ 9.5
Drain port
20 (Polyvinyl chloride tube)
(Nominal dia. mm)
Sound pressure level (Note 2)
(High/Mid/Low)
(dB(A))
46/43/38
49/45/40
PMV Kit
Not available
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the
reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.
Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in
the actual operating environment become larger than the indicated values due to the effects of external sound.
Note : Rated conditions
Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB
Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB
O
O
O
9-13 -2
O
O
O
9-13-2. Dimension
MMF-AP0151H, AP0181H, AP0241H, AP0271H
Wall
Dimensions
(
Incase of installing distance
is 50mm from wall
)
Model
Lower refrigerant piping port
(50 x 120 Knockout hole)
Installation plate
Discharge
port
A
B
MMF-AP0151H, AP0181H O
/ 12.7
O
/ 6.4
MMF-AP0241H, AP0271H O
/ 15.7
O
/ 9.5
600
30 x 3 30 x 3
80
Wall
Wall
a
b
Wall
Control
part
More
Front than
500
Front
More than
1000
Wall
More than
200
Space required for service
(In case of right side piping )
Control
cover
Wall
Floor
Refrigerant piping port (Both side)
(O
/ 80 Knockout)
Earth screw (M4)
Drain
hose
Installation plate
Suction port
Refrigerant piping hole (Back side)
(O
/ 130 Knockout )
Refrigerant piping position
Refrigerant piping hole (Bottom side)
(50 x 120 Knockout)
Refrigerant piping joint
(Gas side A)
Wired remote controller
RBC-AMT31E
Simple wired remote controller
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E2
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
Refrigerant piping joint
(Liquid side B)
(
)
In case b 1773
2- lower hole
For M8 Screw bolt
or M8 Anchor bolt
In case a 1770
Details of hole for back side piping
Details of hole for lower side piping
4- lower hole
M8 Screw bolt
( For
or M8 Anchor bolt )
O
/ 130 Knockout
50 x 120 (Square opening)
(For under surface piping)
(For backside piping)
Note: All dimensions are in mm.
9-13 -3
MMF-AP0361H, AP0481H
Wall
of installing distance is
( Incase
)
50mm from wall
Lower refrigerant piping port
(50 x 120 Knockout)
Installation plate
Discharge
port
600
30 x 3 30 x 3
80
Wall
Wall
a
b
Wall
Control
part
Control
cover
More
Front than
500
Wall
Front
More than
1000
Wall
More than 200
Space required for service
(In case of right side piping )
Floor
Refrigerant piping port (Both side)
(O
/ 80 Knockout)
Drain hose
Earth screw (M4)
Installation plate
Dtain hose
Suction port
Refrigerant piping hole
(Back side)
(O
/ 130 Knockout)
Refrigerant piping hole (Bottom side)
(50 x 120 Knockout)
Refrigerant piping position
Refrigerant piping joint
(Gas side O
/ 19)
Wired remote controller
RBC-AMT31E
Gas side
Liquid
side
Simple wired remote controller
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E2
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
Refrigerant piping joint
(Liquid side O
/ 9.5)
Details of hole for lower side piping
In case b 1773
2- lower hole
M8 Screw bolt
( For
or M8 Anchor bolt )
In case a 1770
Details of hole for back side piping
O
/ 130 Knockout
4- lower hole
M8 Screw bolt
( For
or M8 Anchor bolt )
(For backside piping)
50 x 120 (Square opening)
(For under surface piping)
Note: All dimensions are in mm.
9-13 -4
RED
FM
Closed-end
connector
1 1
3
1
P301
(BLK)
FUSE
(YEL)
CN309
1 2
1 2
CN040
(BLU)
(BLK)
CN067
Outdoor unit
U1 U2
U1 U2
1 2
1 2
B
1 2
1 2
CN1
A
3 3
2
1 1
H
MCC-1401
3
3
3
3.
1
1
LM
2 1
2 1
1 2 3 4 5 6 CN02
(YEL)
1 2 3 4 5 6
the letter inside indicates the terminal number.
Indicates the control p.c. board.
the wiring on site.
TR
1 2 3 4 5 6 CN01
1 2 3 4 5 6 (WHI)
Sub P.C. board
MCC-1520
CN061
(YEL)
.
1 2 3 4 5 6
OPTION
1 2
CN060
(WHI)
CN081
(BLK)
CN070
(WHI)
CN073
(RED)
CN080
(GRN)
CN100
(BRW)
CN101
(BLK)
CN102
(RED)
CN104
(YEL)
TC2
TCJ
TA
FILTER
TC1
RED : RED
WHI : WHITE
YEL :YELLOW
BLU : BLUE
BLK : BLACK
GRY : GRAY
PNK : PINK
ORN :ORANGE
BRN : BROWN
GRN : GREEN
Color
indication
Parts name
Fan motor
Running capacitor
Transformer
Lover motor
Indoor temp sensor
Temp sensor
Louver control relay
Drain control relay
Fan motor control relay
Pulse motor valve
1
2
3
4
5
1
2
1
EXCT
2
1
2 PNL
3
3 3
1 1
1 1
2 2
1 1
2 2
1 1
2 2
PMV
1 2 3 4 5 6 CN082
1 2 3 4 5 6 (BLU)
FAN
DRIVE
CN032
(WHI)
PMV
6 4 3 1 2 5
6 4 3 1 2 5
Symbol
FM
RC
TR
LM
TA
TC1,TC2,TCJ
RY001
RY002
RY005~007
PMV
1 2 3 4 5 6
CN075
(WHI)
1 2 3 4 5 6
1 2 3 4 5 6
FS
1
3 CN030
1 2 3 (RED)
Control P.C. board
for Indoor unit
MCC-1403
LM
3 CN033
3 (GRN)
Power supply
circuit
RY001
DP
Indicates the terminal bolock, letter.
X Y
1 2
1 2
CN03(RED)
CN02
(BLU)
CN074 1
(WHI) 1
RY002
Network Adapter
(Option)
CN01(WHI)
1 2
1 2
1 2 3 4 5
CN050
(WHI)
UL
CN068
(BLU) 1
2 . A dotted line and broken line indicate
1.
L
RY005
RY006
M
Remote Controller
1 2 3 RC
1
3
RY007
RED BLK ORN BLU YEL
FAN
7
5
3
1
CN083 9
(WHI) 9
7
5
3
1
CN041
(BLU)
RY004
(GRY)
CN304
T5.0A 250V~
Line Filter
TR
EMG
CN066
(WHI)
1
2
CN044
(BRW)
1
2
3 3
3 3
AC IN
1 1
BRW
Flow selector
unit earth
screw
Power supply
single phase
220-240V 50Hz
220V 60Hz
R(L) S(N)
Indoor unit
earth screw
WHI
RC
BLU
3
4
5
6
7
BLU
3
4
5
6
7
8
BLK
9-13 -5
BLK
1 1
9-13-3. Wiring diagram
Model: MMF-AP0151H, AP0181H, AP0241H, AP0271H, AP0361H, AP0481H, AP0561H
9-13-4. Sensible capacity table
(MMF-AP***H)
Cooling capacity
Unit
size
015
018
024
Outdoor
air temp.
˚CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
16.0˚CWB
23˚CDB
TC
SHC
4.1
3.2
4.1
3.2
4.1
3.2
4.1
3.2
4.1
3.2
4.1
3.2
4.1
3.2
4.1
3.2
4.1
3.2
4.1
3.2
4.1
3.2
4.1
3.2
4.1
3.2
4.1
3.2
4.0
3.1
3.9
3.0
5.1
3.9
5.1
3.9
5.1
3.9
5.1
3.9
5.1
3.9
5.1
3.9
5.1
3.9
5.1
3.9
5.1
3.9
5.1
3.9
5.1
3.9
5.1
3.9
5.1
3.9
5.1
3.9
5.0
3.8
4.9
3.6
6.4
5.0
6.4
5.0
6.4
5.0
6.4
5.0
6.4
5.0
6.4
5.0
6.4
5.0
6.4
5.0
6.4
5.0
6.4
5.0
6.4
5.0
6.4
5.0
6.4
5.0
6.4
5.0
6.3
4.9
6.2
4.7
18.0˚CWB
26˚CDB
TC
SHC
4.4
3.4
4.4
3.4
4.4
3.4
4.4
3.4
4.4
3.4
4.4
3.4
4.4
3.4
4.4
3.4
4.4
3.4
4.4
3.4
4.4
3.4
4.4
3.4
4.4
3.4
4.4
3.4
4.3
3.3
4.2
3.2
5.4
4.1
5.4
4.1
5.4
4.1
5.4
4.1
5.4
4.1
5.4
4.1
5.4
4.1
5.4
4.1
5.4
4.1
5.4
4.1
5.4
4.1
5.4
4.1
5.4
4.1
5.4
4.1
5.3
4.0
5.2
3.9
6.9
5.3
6.9
5.3
6.9
5.3
6.9
5.3
6.9
5.3
6.9
5.3
6.9
5.3
6.9
5.3
6.9
5.3
6.9
5.3
6.9
5.3
6.9
5.3
6.9
5.3
6.9
5.3
6.7
5.2
6.6
5.0
TC : Total Capacity (kW) SHC : Sensible Heat Capacity (kW)
Indoor air temp.
19.0˚CWB
20.0˚CWB
22.0˚CWB
24.0˚CWB
27˚CDB
28˚CDB
30˚CDB
32˚CDB
TC
SHC
TC
SHC
TC
SHC
TC
SHC
4.5
3.4
4.6
3.4
4.9
3.4
5.1
3.3
4.5
3.4
4.6
3.4
4.9
3.4
5.1
3.3
4.5
3.4
4.6
3.4
4.9
3.4
5.1
3.3
4.5
3.4
4.6
3.4
4.9
3.4
5.1
3.3
4.5
3.4
4.6
3.4
4.9
3.4
5.1
3.3
4.5
3.4
4.6
3.4
4.9
3.4
5.1
3.3
4.5
3.4
4.6
3.4
4.9
3.4
5.1
3.3
4.5
3.4
4.6
3.4
4.9
3.4
5.1
3.3
4.5
3.4
4.6
3.4
4.9
3.4
5.1
3.3
4.5
3.4
4.6
3.4
4.9
3.4
5.1
3.3
4.5
3.4
4.6
3.4
4.9
3.4
5.1
3.3
4.5
3.4
4.6
3.4
4.9
3.4
5.1
3.3
4.5
3.4
4.6
3.4
4.9
3.4
5.1
3.3
4.5
3.4
4.6
3.4
4.9
3.4
5.1
3.3
4.4
3.3
4.5
3.3
4.8
3.3
5.0
3.2
4.3
3.2
4.4
3.2
4.7
3.2
4.9
3.1
5.6
4.1
5.8
4.1
6.1
4.1
6.4
4.0
5.6
4.1
5.8
4.1
6.1
4.1
6.4
4.0
5.6
4.1
5.8
4.1
6.1
4.1
6.4
4.0
5.6
4.1
5.8
4.1
6.1
4.1
6.4
4.0
5.6
4.1
5.8
4.1
6.1
4.1
6.4
4.0
5.6
4.1
5.8
4.1
6.1
4.1
6.4
4.0
5.6
4.1
5.8
4.1
6.1
4.1
6.4
4.0
5.6
4.1
5.8
4.1
6.1
4.1
6.4
4.0
5.6
4.1
5.8
4.1
6.1
4.1
6.4
4.0
5.6
4.1
5.8
4.1
6.1
4.1
6.4
4.0
5.6
4.1
5.8
4.1
6.1
4.1
6.4
4.0
5.6
4.1
5.8
4.1
6.1
4.1
6.4
4.0
5.6
4.1
5.8
4.1
6.1
4.1
6.4
4.0
5.6
4.1
5.8
4.1
6.1
4.1
6.4
4.0
5.5
4.0
5.7
4.0
6.0
4.0
6.3
3.9
5.4
3.9
5.5
3.9
5.9
3.8
6.1
3.7
7.1
5.3
7.3
5.3
7.7
5.3
8.1
5.1
7.1
5.3
7.3
5.3
7.7
5.3
8.1
5.1
7.1
5.3
7.3
5.3
7.7
5.3
8.1
5.1
7.1
5.3
7.3
5.3
7.7
5.3
8.1
5.1
7.1
5.3
7.3
5.3
7.7
5.3
8.1
5.1
7.1
5.3
7.3
5.3
7.7
5.3
8.1
5.1
7.1
5.3
7.3
5.3
7.7
5.3
8.1
5.1
7.1
5.3
7.3
5.3
7.7
5.3
8.1
5.1
7.1
5.3
7.3
5.3
7.7
5.3
8.1
5.1
7.1
5.3
7.3
5.3
7.7
5.3
8.1
5.1
7.1
5.3
7.3
5.3
7.7
5.3
8.1
5.1
7.1
5.3
7.3
5.3
7.7
5.3
8.1
5.1
7.1
5.3
7.3
5.3
7.7
5.3
8.1
5.1
7.1
5.3
7.3
5.3
7.7
5.3
8.1
5.1
7.0
5.2
7.2
5.2
7.6
5.1
7.9
5.0
6.8
5.0
7.0
5.0
7.4
4.9
7.8
4.8
9-13 -6
Cooling capacity (cont.)
Unit
size
027
036
048
Outdoor
air temp.
˚CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
16.0˚CWB
23˚CDB
TC
SHC
7.3
5.6
7.3
5.6
7.3
5.6
7.3
5.6
7.3
5.6
7.3
5.6
7.3
5.6
7.3
5.6
7.3
5.6
7.3
5.6
7.3
5.6
7.3
5.6
7.3
5.6
7.3
5.6
7.1
5.5
7.0
5.2
10.2
7.6
10.2
7.6
10.2
7.6
10.2
7.6
10.2
7.6
10.2
7.6
10.2
7.6
10.2
7.6
10.2
7.6
10.2
7.6
10.2
7.6
10.2
7.6
10.2
7.6
10.2
7.6
10.0
7.4
9.8
7.1
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.7
9.3
12.5
9.2
12.2
8.8
18.0˚CWB
26˚CDB
TC
SHC
7.8
5.9
7.8
5.9
7.8
5.9
7.8
5.9
7.8
5.9
7.8
5.9
7.8
5.9
7.8
5.9
7.8
5.9
7.8
5.9
7.8
5.9
7.8
5.9
7.8
5.9
7.8
5.9
7.6
5.8
7.4
5.6
10.9
8.0
10.9
8.0
10.9
8.0
10.9
8.0
10.9
8.0
10.9
8.0
10.9
8.0
10.9
8.0
10.9
8.0
10.9
8.0
10.9
8.0
10.9
8.0
10.9
8.0
10.9
8.0
10.6
7.9
10.4
7.5
13.6
9.9
13.6
9.9
13.6
9.9
13.6
9.9
13.6
9.9
13.6
9.9
13.6
9.9
13.6
9.9
13.6
9.9
13.6
9.9
13.6
9.9
13.6
9.9
13.6
9.9
13.6
9.9
13.3
9.7
13.0
9.3
Indoor air temp.
19.0˚CWB
27˚CDB
TC
SHC
8.0
5.9
8.0
5.9
8.0
5.9
8.0
5.9
8.0
5.9
8.0
5.9
8.0
5.9
8.0
5.9
8.0
5.9
8.0
5.9
8.0
5.9
8.0
5.9
8.0
5.9
8.0
5.9
7.8
5.8
7.7
5.6
11.2
8.0
11.2
8.0
11.2
8.0
11.2
8.0
11.2
8.0
11.2
8.0
11.2
8.0
11.2
8.0
11.2
8.0
11.2
8.0
11.2
8.0
11.2
8.0
11.2
8.0
11.2
8.0
11.0
7.8
10.8
7.5
14.0
9.9
14.0
9.9
14.0
9.9
14.0
9.9
14.0
9.9
14.0
9.9
14.0
9.9
14.0
9.9
14.0
9.9
14.0
9.9
14.0
9.9
14.0
9.9
14.0
9.9
14.0
9.9
13.7
9.7
13.4
9.3
20.0˚CWB
28˚CDB
TC
SHC
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.2
5.9
8.1
5.8
7.9
5.6
11.5
8.0
11.5
8.0
11.5
8.0
11.5
8.0
11.5
8.0
11.5
8.0
11.5
8.0
11.5
8.0
11.5
8.0
11.5
8.0
11.5
8.0
11.5
8.0
11.5
8.0
11.5
8.0
11.3
7.8
11.1
7.5
14.4
9.9
14.4
9.9
14.4
9.9
14.4
9.9
14.4
9.9
14.4
9.9
14.4
9.9
14.4
9.9
14.4
9.9
14.4
9.9
14.4
9.9
14.4
9.9
14.4
9.9
14.4
9.9
14.1
9.7
13.8
9.3
9-13 -7
22.0˚CWB
30˚CDB
TC
SHC
8.7
5.8
8.7
5.8
8.7
5.8
8.7
5.8
8.7
5.8
8.7
5.8
8.7
5.8
8.7
5.8
8.7
5.8
8.7
5.8
8.7
5.8
8.7
5.8
8.7
5.8
8.7
5.8
8.5
5.7
8.4
5.5
12.2
7.9
12.2
7.9
12.2
7.9
12.2
7.9
12.2
7.9
12.2
7.9
12.2
7.9
12.2
7.9
12.2
7.9
12.2
7.9
12.2
7.9
12.2
7.9
12.2
7.9
12.2
7.9
12.0
7.8
11.7
7.5
15.3
9.8
15.3
9.8
15.3
9.8
15.3
9.8
15.3
9.8
15.3
9.8
15.3
9.8
15.3
9.8
15.3
9.8
15.3
9.8
15.3
9.8
15.3
9.8
15.3
9.8
15.3
9.8
15.0
9.6
14.6
9.2
24.0˚CWB
32˚CDB
TC
SHC
9.1
5.7
9.1
5.7
9.1
5.7
9.1
5.7
9.1
5.7
9.1
5.7
9.1
5.7
9.1
5.7
9.1
5.7
9.1
5.7
9.1
5.7
9.1
5.7
9.1
5.7
9.1
5.7
8.9
5.6
8.8
5.4
12.8
7.7
12.8
7.7
12.8
7.7
12.8
7.7
12.8
7.7
12.8
7.7
12.8
7.7
12.8
7.7
12.8
7.7
12.8
7.7
12.8
7.7
12.8
7.7
12.8
7.7
12.8
7.7
12.5
7.6
12.3
7.3
16.0
9.6
16.0
9.6
16.0
9.6
16.0
9.6
16.0
9.6
16.0
9.6
16.0
9.6
16.0
9.6
16.0
9.6
16.0
9.6
16.0
9.6
16.0
9.6
16.0
9.6
16.0
9.6
15.6
9.4
15.3
9.0
Heating capacity
Unit
size
015
018
024
Outdoor
air temp.
˚CWB
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
SHC
3.1
3.3
3.6
3.7
3.9
4.1
4.3
4.5
4.7
4.8
5.0
5.2
5.2
5.2
5.2
5.2
3.9
4.2
4.5
4.6
4.9
5.1
5.4
5.6
5.9
6.1
6.3
6.6
6.6
6.6
6.6
6.6
5.0
5.3
5.7
5.8
6.2
6.5
6.8
7.1
7.4
7.7
8.0
8.3
8.3
8.3
8.3
8.3
SHC : Sensible Heat Capacity (kW)
Indoor air temp. ˚CDB
18.0
20.0
22.0
24.0
SHC
SHC
SHC
SHC
3.1
3.0
2.9
2.9
3.3
3.2
3.1
3.0
3.5
3.4
3.3
3.2
3.6
3.5
3.4
3.3
3.8
3.7
3.6
3.5
4.0
3.9
3.8
3.7
4.2
4.1
4.0
3.9
4.4
4.3
4.2
4.1
4.6
4.5
4.4
4.2
4.7
4.6
4.5
4.4
4.9
4.8
4.7
4.6
5.1
5.0
4.9
4.8
5.1
5.0
4.9
4.8
5.1
5.0
4.9
4.8
5.1
5.0
4.9
4.8
5.1
5.0
4.9
4.8
3.9
3.8
3.7
3.6
4.1
4.0
3.9
3.8
4.4
4.3
4.2
4.1
4.5
4.4
4.3
4.2
4.8
4.7
4.6
4.4
5.0
4.9
4.8
4.7
5.3
5.2
5.0
4.9
5.5
5.4
5.3
5.1
5.8
5.6
5.5
5.3
6.0
5.9
5.7
5.6
6.2
6.1
5.9
5.8
6.4
6.3
6.1
6.0
6.4
6.3
6.1
6.0
6.4
6.3
6.1
6.0
6.4
6.3
6.1
6.0
6.4
6.3
6.1
6.0
4.9
4.8
4.7
4.6
5.2
5.1
5.0
4.9
5.6
5.5
5.3
5.2
5.7
5.6
5.5
5.3
6.1
5.9
5.8
5.6
6.4
6.2
6.1
5.9
6.7
6.6
6.4
6.2
7.0
6.9
6.7
6.5
7.3
7.1
7.0
6.8
7.6
7.4
7.3
7.1
7.9
7.7
7.5
7.3
8.2
8.0
7.8
7.6
8.2
8.0
7.8
7.6
8.2
8.0
7.8
7.6
8.2
8.0
7.8
7.6
8.2
8.0
7.8
7.6
9-13 -8
Heating capacity (cont.)
Unit
size
027
036
048
Outdoor
air temp.
˚CWB
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
-15.0
-13.0
-11.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
SHC
5.6
6.0
6.4
6.6
7.0
7.3
7.7
8.0
8.4
8.7
9.0
9.4
9.4
9.4
9.4
9.4
7.8
8.3
8.9
9.1
9.7
10.2
10.7
11.1
11.6
12.1
12.6
13.0
13.0
13.0
13.0
13.0
10.0
10.7
11.4
11.7
12.4
13.0
13.6
14.3
14.9
15.5
16.1
16.7
16.7
16.7
16.7
16.7
Indoor air temp. ˚CDB
18.0
20.0
22.0
SHC
SHC
SHC
5.5
5.4
5.3
5.9
5.8
5.6
6.3
6.1
6.0
6.5
6.3
6.2
6.8
6.7
6.5
7.2
7.0
6.9
7.5
7.4
7.2
7.9
7.7
7.5
8.2
8.0
7.8
8.5
8.4
8.2
8.9
8.7
8.5
9.2
9.0
8.8
9.2
9.0
8.8
9.2
9.0
8.8
9.2
9.0
8.8
9.2
9.0
8.8
7.7
7.5
7.3
8.2
8.0
7.8
8.7
8.5
8.3
9.0
8.8
8.6
9.5
9.3
9.1
10.0
9.8
9.5
10.5
10.2
10.0
10.9
10.7
10.5
11.4
11.2
10.9
11.9
11.6
11.3
12.3
12.1
11.8
12.8
12.5
12.2
12.8
12.5
12.2
12.8
12.5
12.2
12.8
12.5
12.2
12.8
12.5
12.2
9.8
9.6
9.4
10.5
10.3
10.0
11.1
10.9
10.7
11.5
11.2
11.0
12.1
11.9
11.6
12.8
12.5
12.2
13.4
13.1
12.8
14.0
13.7
13.4
14.6
14.3
14.0
15.2
14.9
14.5
15.8
15.4
15.1
16.3
16.0
15.6
16.3
16.0
15.6
16.3
16.0
15.6
16.3
16.0
15.6
16.3
16.0
15.6
24.0
SHC
5.1
5.5
5.8
6.0
6.3
6.7
7.0
7.3
7.6
7.9
8.3
8.6
8.6
8.6
8.6
8.6
7.2
7.6
8.1
8.3
8.8
9.3
9.7
10.2
10.6
11.0
11.5
11.9
11.9
11.9
11.9
11.9
9.1
9.7
10.4
10.7
11.3
11.9
12.4
13.0
13.6
14.1
14.7
15.2
15.2
15.2
15.2
15.2
9-13 -9
9-13-5. Air throw distance chart
MMF-AP0151H, AP0181H
(m)
(m)
2.7
MMF-AP0241H, AP0271H
2.7
0.5m/s
2.0
2.0
0.5m/s
1.5m/s
0.7m/s
1.0m/s
1.5m/s
1.0
1.0m/s
1.0
1
2
3
4
5
6
7
8
(m)
MMF-AP0361H
(m)
1
(m)
2.7
2
3
4
5
6
7
8
(m)
MMF-AP0481H,AP0561H
2.7
2.0
1.5m/s
2.0m/s
0.5m/s
1.0m/s
2.0
1.5m/s
1.0
1.5m/s
1.5m/s
1.0m/s
1.0
1
2
3
4
5
6
7
8
(m)
1
9-13 -10
2
3
4
5
6
7
8
(m)
9-13-6. Accessories
Apperarance
Standard accessories
Attached position
Part name
Upper part of main unit Bracket for fixing to wall
Qty
Shape
Stored position
1
Installation Manual
1
Thermal insulator
2
Indoor unit
Accessory bag
Screw bolt
Thermal insulator
4 (2)
Base for
transportation
2
Using 4 (2) screw bolts,
fix to the base.
Lower part of main unit Bracket for fixing to floor
2
Quantities in the above table are for MMF-AP0361, AP0481 and AP0561 models.
The brackets for fixing to the floor are already mounted on the indoor unit.
Optional accessories
Remote controller
Model Name
Wired remote controller
RBC-AMT31E
Simple wired remote controller
RBC-AS21E2
Wireless remote controller kit
TCB-AX21E2
Weekly timer application
RBC-AMT31E and RBC-EXW21E2
Central remote controller
TCB-SC642TLE2
ON-OFF controller
TCB-CC163TLE2
9-13 -11
[1] Remote location ON/OFF control box
Model
Name
Features
Appearance
TCB-IFCB-4E2
Start and stop of the air conditioner is possible
by a external signal and indication of
operation/alarm externally.
Application
Function
Monitoring
ON/OFF status (for indoor unit)
Alarm status (system & indoor unit stop)
ON/OFF command
Air conditioner can be turned ON/OFF
by external signals.
The external ON/OFF signals
will initiate the signals shown below.
Operation
Interface
Display
Remote
Controller
ON /OFF
Non-voltage
ON /OFF continious signal
COM
Dimension
Outside view
Inside view
200
Fix this control box to the place
besides the indoor unit.
1
78
6- 5.5 mounting hole
Approx. 300
78
22
66
63.6
6
Approx.
1500
22
78
78
170
5
146.9
3
22
156
2
4
22
Note : All dimensions are in mm
(NOTE) Do not install the accessory parts at
the following locations.
1. Location where combustible gas may leak
2. Location where direct sunlight shines
3. Location with high humidity such as bathroom,
kitchen, etc.
4. Location with high levels of dust
5. Location where rain or dew drops such as
outdoors
6. Location in 1m-range of a TV or radio
Name
No.
Specification
1
Case unit
2
Case cover
Galvanized steel 0.8t
3
Harness to connect indoor unit
P.C. board
CN61 connector
4
Harness for indication cable
UL1015 AWG18 tip-insulation type butt connector
5
Harness for power supply
3-core, 0.75mm2
6
Harness for ON/OFF command
UL1015 AWG18 tip-insulation type butt connector
Galvanized steel 0.8t
9-14 -1
Panels and accessories
Indoor unit type
Accessory parts name
Model
4-way Air Discharge
Cassette Type
Optional
Super Long Life Filter
TCB-LF1601UE2
High Efficiency Filter 65
TCB-UFM1601UE
High Efficiency Filter 90
TCB-UFH1601UE
Fresh air and Filter
Chamber
TCB-GFC1601UE2
Fresh air inlet Box
TCB-GB1601UE2
Auxiliary fresh air Flange
TCB-FF101URE2
Spacer for height
adjustment
TCB-SP1601UE
Optional
2-way Air Discharge
Cassette Type
***
Fresh Air Chamber
***
Fresh Air Intel Box
***
Required accessory Ceiling panel
Required accessory Ceiling panel
1-way Air Discharge
Cassette Type
Optional
China market only
AP0071-0121/AP0241-0301 AP0241-AP0301 use two pcs.
TCB-UFM21BFCE
AP0151-0181/AP0361-0481 AP0361-AP0481 use two pcs.
TCB-UFM11BE
AP0071-0121
TCB-UFM21BE
AP0151-0181
TCB-UFM31BE
AP0241-0301
TCB-UFM41BE
AP0361-0481
TCB-UFH51BFCE
TCB-UFH61BFCE
AP0071-0121/AP0241-0301 AP0241-AP0301 use two pcs.
AP0151-0181/AP0361-0481 AP0361-AP0481 use two pcs.
TCB-UFH51BE
AP0071-0121
TCB-UFH61BE
AP0151-0181
TCB-UFH71BE
AP0241-0301
TCB-UFH81BE
AP0361-0481
RBC-UD281PE(W)
AP0071-0121
RBC-UD501PE(W)
AP0151-0181
RBC-UD801PE(W)
AP0241-0301
RBC-UD1401PE(W)
AP0361-0481
TCB-CA281BE
AP0071-0121
TCB-CA501BE
AP0151-0181
TCB-CA801BE
AP0241-0301
TCB-CA1401BE
AP0361-0481
TCB-FC281BE
AP0071-0121
TCB-FC501BE
AP0151-0181
TCB-FC801BE
AP0241-0301
TCB-FC1401BE
AP0361-0481
TCB-FK281BE
AP0071-0121
TCB-FK501BE
AP0151-0181
TCB-FK801BE
AP0241-0301
TCB-FK1401BE
AP0361-0481
TCB-UFM1D-1E
AP0181/0481
AP0481 use two pcs.
TCB-UFM2D-1E
AP0241-0361
Use two pcs.
TCB-UFH5D-1E
AP0181/0481
AP0481 use two pcs.
TCB-UFH6D-1E
AP0241-0361
Use two pcs.
TCB-PF1D-1E
AP0181/0481
AP0481 use two pcs.
TCB-PF2D-1E
AP0241-0361
Use two pcs.
TCB-FCY21DE
AP0181
TCB-FCY31DE
AP0241-0361
TCB-FCY51DE
AP0481
Drain pump kit
TCB-DP31DE
AP0181-0481
Drain pump kit
TCB-DP22CE2
AP0151-0481
TCB-KP12CE2
AP0151-0181
TCB-KP22CE2
AP0241-0481
Ceiling panel
High Efficiency Filter 65
High Efficiency Filter 90
Long Life Pre-Filter
Filter Chamber
Optional
AP0481
RBC-US21PGE
TCB-UFM11BFCE
Filter kit for underside
Under Ceiling Type
AP0151-0301
RBC-UW466PG
TCB-FF101URE
Filter Chamber
Optional
AP0071-0121
RBC-UW266PG
TCB-BU21HWE
Suction Canvas
Concealed Duct High
Static Pressure Type
***
Auxiliary fresh air flange
High Efficiency Filter 90
Optional
Three-piece set
RBC-UW136PG
Front air discharge unit
High Efficiency Filter 65
Concealed Duct Type
Be used with TCB-GFC1601UE2
RBC-UM11PG(W)E
Spacer for height adjustment
Air Discharge Direction Kit
Remarks
Be used with TCB-GFC1601UE2
TCB-BC1601UE
Air discharge direction kit
Required accessory Ceiling panel
Compact 4-way Air
Discharge Cassette
(600 x 600) Type
Application model
RBC-U21PG(W)-E2
Required accessory Ceiling panel
Elbow piping kit
9-14 -2
For underside suction
For underside suction
(Half panel for underside
suction)
For underside suction
For rear suction
*Required accessories when
using Drain Pump Kit
PMV-Kit (RBM-PMV0361E/RBM-PMV0901E) shall be required for quiter place application as
an optional to reduce refrigerant sound especially in oil retrieval control or in transient operation
as start up.
10-1. Selection
Model name
RBM-PMV0361E
Indoor unit capacity type
007,009,012 type
015,018 type
024 type
RBM-PMV0901E
Diameter of refrigerant pipe
O
/ 6.4
O
/ 6.4
O
/ 9.5
Allowable length of refrigerant piping
2 m to 10 m
NO GOOD
OK
PMV Kit
PMV Kit
Indoor unit
PMV Kit
Refrigerant pipe
Indoor unit
Indoor unit
Note)
Do not connect two or more indoor units to one PMV Kit.
Arrange one indoor unit and one PMV Kit set to 1 by 1.
• Connecting direction of refrigerant pipe
When connecting pipes, be careful of direction of the
main unit. Be sure to install the main unit so that
[
] mark in the label directs upward.
For connection of the refrigerant pipes, follow the
arrow mark in the label and connect pipes after
confirming directions of indoor unit and outdoor unit.
Label
Piping material and dimensions
Model name
Indoor unit capacity type
Diameter of refrigerant pipe
RBM-PMV0361E
007, 009, 012 type
Ø6.4
015, 018 type
Ø6.4
RBM-PMV0901E
Notes
Attached joint
024 type
Ø9.5
10 -1
Attached joint
Fixation after connection pipes
Set the hanging bolts for supporting pipes which are mounted at front and rear sides of PMV
Kit at within 1m intervals.
1 m or less
Hanging bolt
Hanging bolt
Refrigerant pipe
PMV Kit
10 -2
10-2. W
iring connections
Wiring
For this product , the connector co nve rsion ca ble (Accessory) is used according to the
indoor unit to be connected .
For the corresponding unit and how to use the conversio n cable, refer the following desc ription.
Indoor unit which connector conversion ca ble is not used
High Wall Type 2 se ries (MMK-AP0072H, MMK-AP0092H, MMK-AP0122H )
Connector conversion cable
Connection cable
Remove the connector conversio n cable which is attached to the connection cable (11m) out of the box.
Indoor unit whi ch connector
conve rsion ca ble is used
Indoor unit excep t above indoor units
Connection cable
Connector conversion cable
10
.2006)
7.Apr.2006)
-3 (Revised edition in 7.Apr
10-3. Dimension
PMV Kit
RBM-PMV0361E, RBM-PMV0901E
Refrigerant pipe connecting
port (Liquid pipe)
Refrigerant pipe connecting
port (Liquid pipe)
55
58
226
55
Connection cable
(accessory)
30
26
500 or more
Check port
450 x 450
55
55
200 or more
RBM-PMV0901E
(When attached joint are used)200 or more
Installation image
Binding band M
Binding band L
Binding band M
Refrigerant pipe (Gas side)
Heat insulating pipe
Refrigerant pipe (Liquid side)
50 or more
Binding band M
73
200 or more
Heat insulating pipe
73
50 or more
Binding band L
Binding band M
50
or more
Box cover
RBM-PMV0361E,PMV0901E
50
or more
50
or more
161
76
76
36
30
200 or more
Refrigerant pipe (Liquid side)
Note: All dimensions are in mm.
10 -4
11-1. Specifications
50Hz
Specifications (50Hz)
Equivalent HP
Equivalent to 4HP
Equivalent to 5HP
Equivalent to 6HP
MMY-
MCY-MAP0401HT2D
MCY-MAP0501HT2D
MCY-MAP0601HT2D
Cooling capacity (*1)
(kW)
12.1
14.0
15.5
Standard heating capacity (*1)
(kW)
12.5
16.0
18.0
Model name
Outdoor unit type
Inverter unit
Power supply (*2)
1 phase 60Hz 220V
(A)
13.8
16.8
22.4
Power consumption
(kW)
2.82
3.47
4.63
Power factor
(%)
93
94
94
(kW/kW)
4.29
4.03
3.35
Running current
Cooling
EER (Energy Efficiency Ratio)
Electrical
characteristics
(*1)
Heating
Starting current
(A)
Running current
(A)
13.1
19.1
23.2
Power consumption
(kW)
2.71
4.00
4.85
Power factor
(%)
94
95
95
(kW/kW)
4.61
4.00
3.71
EER (Energy Efficiency Ratio)
Starting current
External dimension
Soft start
(A)
Soft start
(mm)
Height 1,340/Width 900/Depth 320
117
(kg)
Total weight
Shilky shade (Munsell 1Y8.5/0.5)
Color
Compressor
Hermetic Type
Type
(kW)
Motor output
2.3
3.1
Propeller fan (Quantity 2)
Fan
Fan unit
Motor output
(kW)
Air volume
(m3 /h)
0.063 + 0.063
5,820
6,120
Finned tube
Heat exchanger
Refrigerant R410A (Charged refrigerant amount) (*3)
High-pressure switch
(kg)
7.2
(MPa)
Open : 3.73 Close : 2.9
6,420
*5
Protective devices
Connecting port dia
Connecting method
Gas side
(mm)
Liquid side
(mm)
15.9
Discharge gas side
Max. equivalent length
Refrigerant piping Max. real length
specifications (*4)
Max. total pipe length (Real length)
Flare
(m)
(m)
15
125 (If the total bend length exceeds 125m, use the max equivalent
length as the standard.)
(m)
(m)
Real length between PMV Kit and indoor unit
(m)
Outdoor unit is higher than indoor unit : 30
Outdoor unit is lower than indoor unit : 20
2-10
Control wiring
Total wire length(indoor unit- indoor unit/ indoor unit-outdoor unit control wiring,
central control wiring)
Shield wire 1.25mm2 2cores, up to 1000m
Shield wire 2.0mm2 2cores, up to 2000m
6
8
9
(dB(A))
49/50
50/52
51/53
(dB(A))
46/48
46/48
47/49
Max. No. of connected indoor units
Night operation (Sound reduction)control*4
Brazing
Flare
Max. Height between indoor units
Sound pressure level (Cooling/Heating) *3
19.1
9.5
Liquid side
Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB
Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB/6oC WB
The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter
height.
The source voltage must not fluctuate more than ±10%.
The amount does not consider extra piping lengths. Refrigerant must be added on site in accordance with the actual piping length.
The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side.
Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure switch, Over-current sensor,
High-pressure sensor, Low pressure sensor, Over-current relay.
*1 : Rated conditions
*2 :
*3 :
*4 :
*5 :
4.2
11 -1
60Hz
Specifications (60Hz)
Equivalent to 4HP
Equivalent to 5HP
Equivalent to 6HP
MMY-
MCY-MAP0401HT2D
MCY-MAP0501HT2D
MCY-MAP0601HT2D
Cooling capacity (*1)
(kW)
12.1
14.0
15.5
Standard heating capacity (*1)
(kW)
12.5
16.0
18.0
Equivalent HP
Model name
Inverter unit
Outdoor unit type
1 phase 60Hz 220V
Power supply (*2)
(A)
13.8
16.8
22.4
Power consumption
(kW)
2.82
3.47
4.63
Power factor
(%)
93
94
94
(kW/kW)
4.29
4.03
3.35
Running current
Cooling
EER (Energy Efficiency Ratio)
Electrical
characteristics
(*1)
Heating
Starting current
(A)
Running current
(A)
13.1
19.1
23.2
Power consumption
(kW)
2.71
4.00
4.85
Power factor
(%)
94
95
95
(kW/kW)
4.61
4.00
3.71
EER (Energy Efficiency Ratio)
Starting current
External dimension
Soft start
(A)
Soft start
(mm)
Height 1,340/Width 900/Depth 320
117
(kg)
Total weight
Shilky shade (Munsell 1Y8.5/0.5)
Color
Compressor
Hermetic Type
Type
(kW)
Motor output
2.3
3.1
Propeller fan (Quantity 2)
Fan
Fan unit
Motor output
(kW)
Air volume
(m3 /h)
0.063 + 0.063
5,820
6,120
Finned tube
Heat exchanger
Refrigerant R410A (Charged refrigerant amount) (*3)
High-pressure switch
(kg)
7.2
(MPa)
Open : 3.73 Close : 2.9
6,420
*5
Protective devices
Connecting port dia
Connecting method
Gas side
(mm)
Liquid side
(mm)
15.9
Flare
Discharge gas side
Max. equivalent length
Refrigerant piping Max. real length
specifications (*4)
Max. total pipe length (Real length)
(m)
15
(m)
125 (If the total bend length exceeds 125m, use the max equivalent
length as the standard.)
(m)
(m)
Real length between PMV Kit and indoor unit
(m)
Outdoor unit is higher than indoor unit : 30
Outdoor unit is lower than indoor unit : 20
2-10
Control wiring
Total wire length(indoor unit- indoor unit/ indoor unit-outdoor unit control wiring,
central control wiring)
Shield wire 1.25mm2 2cores, up to 1000m
Shield wire 2.0mm2 2cores, up to 2000m
6
8
9
(dB(A))
49/50
50/52
51/53
(dB(A))
46/48
46/48
47/49
Max. No. of connected indoor units
Night operation (Sound reduction)control*4
Brazing
Flare
Max. Height between indoor units
Sound pressure level (Cooling/Heating) *3
19.1
9.5
Liquid side
Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB
Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB/6oC WB
The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter
height.
The source voltage must not fluctuate more than ±10%.
The amount does not consider extra piping lengths. Refrigerant must be added on site in accordance with the actual piping length.
The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side.
Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure switch, Over-current sensor,
High-pressure sensor, Low pressure sensor, Over-current relay.
*1 : Rated conditions
*2 :
*3 :
*4 :
*5 :
4.2
11 -2
11-2. Dimension
MCY-MAP0401HT, MCY-MAP0501HT, MCY-MAP0601HT,
MCY-MAP0401HT2D, MCY-MAP0501HT2D, MCY-MAP0601HT2D
in let
Mounting bolt hole
(O/ 12 x 17slot)
A legs
43
Air outlet
40
54
21
60
108
600
150
Mounting bolt hole
Details of A legs Details of B legs (O/ 12 x 17U-shape cut-out)
320
900
Refrigerant pipe connecting port
(O/ 9.5 flare at liquid side)
89
25
722
718
625
1340
Refrigerant pipe connecting port
(O/ 15.9 flare at gas side)
67
154
350
307
27
7
58
161
400
58
314
95
Knockout for lower piping
86 7
60
27
60
Z
Z View
Diameter of refrigerant pipe
Name
Control wiring and
piping hole
Power supply wiring hole
Notes
Knockout hole O
/ 38
Model name
Gas side
MCY-MAP0401HT*
MCY-MAP0501HT*
O
/ 15.9 (Flare)
O
/ 15.9 (Flare)
MCY-MAP0601HT*
O
/ 19.1
Liquid side
O
/ 9.5 (Flare)
O
/ 9.5 (Flare)
Blazing connection with
attached joint socket.
O
/ 9.5 (Flare)
365
150
or more
Space required for service
2-O
/ 12 x 17U -shape cut-out
(F or M 10 Anchor bolt)
Air inlet
150
or more
Mnimum
distance up to wall
Air outlet
500
or more
46
300
or more
2-O
/ 12 x 17 slot
(F or M 10 Anchor bolt)
80
600
60
165
17.5
26
12
40
Knockout(Drain)
17.5
40
43
Air
let
i in
40
40
365
Drain hole(O/ 20x88)
191
20
Drain hole(O/ 25)
Air
B lege
90
21
29
70
17.5
Knockout(Drain)
32
45
Note: All dimensions are in mm.
11 -3
11-3. Units center of gravity
Model name
1340
900
320
Weight (kg)
Main unit
117
610
MCY-AP0401HT
MCY-AP0401HT2D
MCY-AP0501HT
MCY-AP0501HT2D
MCY-AP0601HT
MCY-AP0601HT2D
H (mm) W (mm) D (mm)
440
150
200
600
365
11 -4
11-4. Wiring diagram
11 -5
11 -6
11-5. Part Load Performance
MCY-MAP0401HT*
Cooling
Compressor + Outdoor fan motor Power consumption (kW)
Outdoor
Temperature
DB˚C
40
35
30
25
20
15
Outdoor unit
100%
100%
90%
80%
70%
Cooling
Load
Load
Load
Load
Capacity
(kW)
11.5
3.07
2.58
2.14
1.76
12.1
2.37
1.97
1.62
2.82
12.1
2.39
2.01
1.68
1.39
12.1
2.03
1.72
1.44
1.20
12.1
1.81
1.53
1.29
1.07
12.1
1.64
1.39
1.17
0.98
Indoor air temperature conditions : 27 ˚CDB, 19˚CWB
Indoor unit fan speed : High
60%
Load
50%
Load
1.43
1.31
1.14
0.99
0.89
0.81
1.16
1.06
0.93
0.82
0.74
0.68
Heating
Outdoor
Temparature
DB˚C WB˚C
15
13.7
11
9.8
7
6
1
0.3
-5
-5.6
-10 -10.5
Compressor + Outdoor fan motor Power consumption (kW)
Outdoor unit
100%
100%
90%
80%
70%
60%
50%
Heating
Load
Load
Load
Load
Load
Load
Capacity
(kW)
12.5
2.38
2.02
1.69
1.38
1.11
0.86
12.5
2.53
2.14
1.79
1.46
1.17
0.90
12.5
2.29
1.91
1.56
1.24
0.96
2.71
11.2
2.59
2.19
1.82
1.49
1.18
0.91
9.9
2.46
2.08
1.73
1.41
1.13
0.87
8.7
2.35
1.99
1.66
1.35
1.08
0.83
Indoor air temperature conditions : 20 ˚CDB
Indoor unit fan speed : High
11 -7
MCY-MAP0501HT*
Cooling
Compressor + Outdoor fan motor Power consumption (kW)
Outdoor unit
Outdoor
100%
100%
90%
80%
70%
60%
50%
Temperature
Cooling
Load
Load
Load
Load
Load
Load
Capacity
DB˚C
(kW)
40
13.3
3.78
3.10
2.52
2.03
1.63
1.34
3.47
35
14.0
2.80
2.28
1.85
1.50
1.19
30
14.0
2.90
2.39
1.95
1.59
1.30
1.08
25
14.0
2.45
2.03
1.67
1.37
1.13
0.96
20
14.0
2.17
1.80
1.48
1.22
1.02
0.87
15
14.0
1.96
1.63
1.35
1.12
0.93
0.80
Indoor air temperature conditions : 27 ˚CDB, 19˚CWB
Indoor unit fan speed : High
Heating
Outdoor
Temparature
DB˚C WB˚C
15
13.7
11
9.8
7
6
1
0.3
-5
-5.6
-10 -10.5
Compressor + Outdoor fan motor Power consumption (kW)
Outdoor unit
100%
70%
60%
50%
100%
90%
80%
Heating
Load
Load
Load
Load
Load
Load
Capacity
(kW)
16.0
3.46
2.98
2.49
2.04
1.64
1.27
16.0
3.71
3.16
2.64
2.16
1.72
1.33
4.00
16.0
3.39
2.82
2.30
1.83
1.41
14.4
3.82
3.23
2.69
2.20
1.75
1.35
12.6
3.63
3.07
2.56
2.09
1.66
1.28
11.1
3.47
2.94
2.45
2.00
1.59
1.23
Indoor air temperature conditions : 20 ˚CDB
Indoor unit fan speed : High
11 -8
MCY-MAP0601HT*
Cooling
Compressor + Outdoor fan motor Power consumption (kW)
Outdoor unit
Outdoor
100%
100%
90%
80%
70%
60%
50%
Temperature
Cooling
Load
Load
Load
Load
Load
Load
Capacity
DB˚C
(kW)
40
14.7
5.05
4.14
3.36
2.70
2.18
1.78
4.63
35
15.5
3.74
3.04
2.47
2.01
1.59
30
15.5
3.71
3.19
2.61
2.12
1.73
1.44
25
15.5
3.03
2.71
2.22
1.83
1.51
1.27
20
15.5
2.64
2.40
1.98
1.63
1.36
1.16
15
15.5
2.37
2.17
1.80
1.49
1.24
1.06
Indoor air temperature conditions : 27 ˚CDB, 19˚CWB
Indoor unit fan speed : High
Heating
Outdoor
Temparature
DB˚C WB˚C
15
13.7
11
9.8
7
6
1
0.3
-5
-5.6
-10 -10.5
Compressor + Outdoor fan motor Power consumption (kW)
Outdoor unit
100%
70%
60%
50%
100%
90%
80%
Heating
Load
Load
Load
Load
Load
Load
Capacity
(kW)
18.0
4.21
3.53
2.90
2.33
1.81
1.35
18.0
4.50
3.77
3.10
2.49
1.93
1.44
4.85
18.0
4.06
3.34
2.67
2.08
1.54
16.2
4.63
3.88
3.18
2.55
1.98
1.47
14.2
4.40
3.68
3.03
2.43
1.88
1.40
12.5
4.21
3.52
2.89
2.32
1.80
1.34
Indoor air temperature conditions : 20 ˚CDB
Indoor unit fan speed : High
11 -9
11-6. Sound Characteristics (NC Curve)
MCY-MAP0401HT
MCY-MAP0501HT
Mode
Cooling
Heating
Mode
Cooling
Heating
Sound pressure level (dB(A))
49
50
Sound pressure level (dB(A))
50
52
90
90
Cooling
70
NC-
60
NC-
50
NC-
40
NC-
30
20
NC-
Approximate threshold of
hearing for continuous noise
Cooling
80
Heating
NC-
10
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
80
Heating
70
NC-
60
NC-
50
NC-
40
NC-
30
20
NC-
NC-
Approximate threshold of
hearing for continuous noise
10
63
125
250
500
1000 2000 4000
Octave band center frequency (Hz)
8000
63
125
250
500
1000 2000 4000
Octave band center frequency (Hz)
8000
MCY-MAP0601HT
Mode
Cooling
Heating
Sound pressure level (dB(A))
51
53
90
Cooling
Octave band sound pressure level (dB)
80
Heating
70
NC-
60
NC-
50
NC-
40
NC-
30
20
NC-
NC-
Approximate threshold of
hearing for continuous noise
10
63
125
250
500
1000 2000 4000
Octave band center frequency (Hz)
8000
[Measuring location]
[Conditions]
Center 1m
Cooling
Outdoor temperature: 35˚CDB, 24˚CWB
Indoor air temperature: 27 ˚CDB, 19˚CW B
Microphone
Heating
Outdoor temperature: 7˚CDB, 6˚CWB
Indoor air temperature: 20 ˚CDB
1.5m
Air outlet
Air inlet
This sound pressure level are measured in an anechoic
chamber in accordance.
11 -10
[Night operation (sound reduction) control ]
MCY-MAP0601HT
MCY-MAP0401HT,MCY-MAP0501HT
Mode
Cooling
Heating
Mode
Cooling
Heating
Sound pressure level (dB(A))
46
48
Sound pressure level (dB(A))
47
49
90
90
Cooling
80
Heating
NC-
60
NC-
50
NC-
40
NC-
30
NC-
20
Octave band sound pressure level (dB)
Octave band sound pressure level (dB)
70
Cooling
80
Heating
70
NC-
60
NC-
50
NC-
40
NC-
30
NC-
20
Approximate threshold of
hearing for continuous noise
NC-
10
NC-
Approximate threshold of
hearing for continuous noise
10
63
125
250
500
1000 2000 4000
Octave band center frequency (Hz)
8000
[Measuring location]
63
125
250
500
1000 2000 4000
Octave band center frequency (Hz)
8000
[Conditions]
Center 1m
Cooling
Outdoor temperature: 25˚CDB, 16˚CWB
Indoor air temperature: 27 ˚CDB, 19˚CWB
Microphone
Heating
Outdoor temperature: 7˚CDB, 6˚CWB
Indoor air temperature: 20 ˚CDB
1.5m
Air outlet
Air inlet
This sound pressure level are measured in an anechoic
chamber in accordance.
11 -11
11-7. Accesories
11-7-1. Branching joints and headers
Branch header
RBM-HY1043E, HY1083E
A
Gas side
80 x n
O
/E
50
O
/D
C
B
Insulator
O
/E
A
Liquid side
80 x n
B
O
/D
O
/D
61
B
Insulator
Model
Gas side
A
B
380
90
ØE
n
83.6 22.2 15.9
3
C
ØD
Accessory socket x Q’ty
6 x 4,
9 x 4,
14 x 1,
18 x 1, 70 x 1
RBM-HY1043E
Liquid side 360
60
700
90
Gas side
74.5
_
15.9 9.5
3
83.6 22.2 15.9
7
RBM-HY1083E
Liquid side 680
60
_
15.9 9.5
7
1 x 4,
6 x 1,
9 x 1
6 x 8,
9 x 8,
14 x 1,
18 x 1
70 x 1
1 x 8,
6 x 1,
9 x 1
Note: All dimensions are in mm.
11 -12
Y-shape branch joint
RBM-BY53E, BY103E
O
/B
O
/D
O
/C
O
/D
Gas side
Insulator
A
O
/D
B
O
/C
O
/D
Liquid side
Insulator
A
Model
A
B
ØC
250
80
15.9 12.7
5 x 2,
54 x 2, 9 x 1,
Liquid side 200
70
12.7
9.5
1 x 2,
5 x 1
350
80
22.2 19.1
7 x 1,
10 x 1,
13 x 2,
52 x 2,
70 x 1,
89 x 1
2 x 1,
5 x 2,
6 x 1,
Gas side
ØD
Accessory socket x Q’ty
51 x 1
RBM-BY53E
Gas side
RBM-BY103E
Liquid side 250
80
15.9 12.7
18 x 1,
9 x 1,
54 x 1
Note: All dimensions are in mm.
11 -13
11-7-2. Application controls of outdoor unit
Note : The P.C. boards of outdoor unit (TCB-PCDM2E, TCB-PCMO2E, TCB-PCIN2E)
can be installed up to two boards.
Model
Name
Appearance
Function
[1] Power peak-cut Control
Normal current
Outdoor unit capacity type
MCY- 0401 type 0501 type
25A
28A
Normal current (Maxim running current)
0601 type
31A
Feature
The upper limit capacity and current of the outdoor unit is
restricted based on the demand request signal from outside.
Wiring
Size : 71 x 85
Input wiring
Output wiring
Application
Len gth
Up to 500m
Up to 200m
Up to 400m
Size
2-core or 3-core, 0.75mm2
2-core, 0.75mm2 *
2-core, 1.5mm2 *
Type
Shield wire
Shield wire
* In conformity with design 60245 IEC 57
Function / Electric wiring diagram
Two type control can be selected by setting SW07 on the
interface P.C. board of the outdoor unit.
[Standard funciton]
TCB-PCDM2E
Outdoor unit
Local Supply
TCB-PCDM2E
I/F P.C Boad
Display
Relay
SW07
Bit2 OFF
Connection
Cable
L1
OPERATION
Power Supply
L1
COM
ON
PJ17
CN513
:Display lamp
suring power
peak-cut
control.
*Install this optional
P.C. board in the
inverter assembly
of the outdoor unit.
SW1
ON
SW2
COM
OFF
SW1
SW2
OFF
Shield wire
In case of pulse signal
Be sure to prepare the point of contact for each terminal.
The time of the pulse signal is more than 100msec.
Don't switch on both SW1 and SW2 terminal simultaneously.
SW07-Bit2 OFF
Input
SW1
OFF
SW2
ON
ON
OFF
SW07-Bit1 OFF
Capacity
Current
SW07-Bit1 ON
Capacity
Current
100%
(Nomal)
100%
(Nomal)
100%
(Normal)
100%
(Normal)
OFF
0% (stop)
0% (stop)
Up to 60%
Up to 80%
ON
Display
Relay (L1)
! CAUTION)
Be sure to prepare a non-voltege point for each terminal.
Display Relay capacity of "OPERATION"
Below AC240V 0.5A (COS =100%)
When connecting load such as relay coil to "L1" load, insert the
noise surge absorber.
Below DC24V 1A (Non-indutive load)
When connecting load such as relay coil to "L1" load, insert the bypass circuit.
11 -14
Model
Name
Appearance
Function
[Expansion function]
Local Supply
Outdoor unit
TCB-PCDM2E
I/F P.C Boad
Display
Relay
SW07
Bit2 ON
OPERATIO
Connection
Cable
PJ17
CN513
Power Supply
L1
COM
ON
SW1
ON
COM
OFF
SW2
OFF
Size : 71 x 85
Shield wire
L1
:Display lamp suring power peak-cut control.
Application
SW07-Bit2 ON
TCB-PCDM2E
Input
SW07-Bit1 OFF
Capacity
Current
SW07-Bit1 ON
Capacity
Current
100%
(Nomal)
100%
(Normal)
Display
Relay (L1)
SW1
OFF
SW2
OFF
ON
OFF Up to 80% Up to 80% Up to 85% Up to 90%
ON
OFF
ON
ON
ON
ON
ON
100%
(Nomal)
100%
(Normal)
Up to 60% Up to 70% Up to 75% Up to 80%
0% (stop) 0% (stop) Up to 60% Up to 70%
OFF
! CAUTION)
*Install this optional
P.C. board in the
inverter assembly
of the outdoor unit.
Be sure to prepare non voltage continuous point of contact for each
terminal.
Display Relay capacity of "OPERATION"
Below AC240V 0.5A (COS =100%)
When connecting load such as relay coil to "L1" load, insert the
noise surge absorber.
Below DC24V 1A (Non-indutive load)
When connecting load such as relay coil to "L1" load, insert the
bypass circuit.
11 -15
Model
Name
Appearance
Function
[2] Snowfall fan control
Feature
Outdoor fan is operated by the snowfall signal from outside.
Function
Local Supply
TCB-PCMO2E
COM
SMC
TCB-PCMO2E
Size : 55.5 x 60
Cooling
Application
SMC : Cooling mode select input (switch)
Terminal
Input signal
Operation
ON
Snowfall fan control
(Operates outdoor fan.)
SMC
OFF
ON
Usual operation
OFF
This control is activated when a input signal increases or decreases.
(The increasing or decreasing signal needs to be held for a minimum of
100m/sec in order to activate the control)
[3] External master ON/OFF control
Feature
The outdoor unit starts or stops the system.
Function
Local Supply
TCB-PCMO2E
COM
SMC
Cooling
Heating
SMH
SMC : Input signal for start
SMH : Input signal for stop
Terminal
*Install this optional
P.C. board in the
inverter assembly
of the outdoor unit.
Input signal
Operation
ON
Starts all indoor units.
SMC
OFF
ON
SMH
Stops all indoor units.
OFF
Ensure terminal contacts are securely fixed.
This control is activated when the input signal increases or decreases
(The increasing or decreasing signal needs to be held for a minimum of
100m/sec in order to activate the control.)
11 -16
Model
Name
Appearance
Function
[4] Night operation (Sound reduction) control
Feature
Sound level can be reduced by restricting the compressor and
fan speeds.
Function
Local Supply
TCB-PCMO2E
COM
TCB-PCMO2E
Size : 55.5 x 60
SMC
Cooling
Application
SMC : Cooling mode designated input switch
Terminal
Input signal
Operation
ON
Night operation control
OFF
ON
SMC
Usual Operation
OFF
This control is activated when the input signal increases or decreases.
(The increasing or decreasing signal needs to be held for a minimum of
100m/sec in order to activate the control).
[5] Operation mode selection control
Feature
This control can restrict the selectable operation mode.
Function
*Install this optional
P.C. board in the
inverter assembly
of the outdoor unit.
Local Supply
TCB-PCMO1E
COM
SMC
Cooling
Heating
SMH
SMC : Cooling mode designated input switch
SMH : Heating mode designated input switch
SMC
SMH
ON
OFF
OFF
ON
Selected operation mode
Only cooling mode
permitted
Only heating mode
permitted
Ensure terminal contacts are securely fixed.
11 -17
Model
Name
Appearance
Function
[6] Error / Operation output control
*
I/F P.C. Board
TCB-PCIN2E
Display
Relay
OPERATION
TCB-PCIN2E
CN511
Power Supply
L1
Connection
Cable
Size : 73.0 x 79
Local Supply
PJ20
Display
Relay
Application
EMG
Power Supply
L2
L1 : Operation monitoring lamp
L2 : Error monitoring lamp
*Install this optional
P.C. board in to the
inverter assembly
of the header
outdoor unit.
Ensure terminal contacts are securely fixed.
Display Relay capacity of "OPERATION" and "EMG"
Below AC240V 0.5A(COSφ=100%)
When connecting a load such as a relay coil to "L1,L2",
insert the noise surge absorber.
Below DC24V 1A(Non-inductive load)
When connecting a load such as a relay coil to "L1,L2",
insert the byass circuit.
11 -18
Dimension
TCB-PCDM2E
71
Terminal
Screw M3 x 6
4-4O
/ hole
75
85
61
Terminal
Screw M4 x 8
TCB-PCMO2E
55.5
4-4O/ hole
45.5
50
60
Terminal
Screw M3 x 6
TCB-PCIN2E
63
73
79
69
Terminal (Screw M3 )
11 -19
4-
4 hole
12 -1
Error/operation output
I/F
Local supply
LONWORKS
Error output
control board
TCB-PCIN2E
External master
ON/OFF board
TCB-PCDMO2E
Power peak-cut
control board
TCB-PCDM2E
LON Gateway
Central remote
controller
TCB-SC642TLE2
ON/OFF Command
Alarm Status output
Weekly timer
RBC-EXW21E2
Master ON/OFF signal
Batch drive, error output
Power Meter
Energy
Monitoring relay
Interface
BMS-IFWH3E
TCS-Net Interface
BMS-IFLSV1E
1 BACnetTM : ANSl/ASHRAE135Ð1995, A Data CommuniCation Protocol for Bulding Automation and ControI Networks.
2 LoNWoRKS¨, Resisterd trademark of Echelon Corporation
Power peak-cut control signal
BMS-LSV4E
Intelligent server
Air-conditioning Management
System on site
Master ON/OFF signal
Monitoring
Remote control
Schedule operation
Error code indication
Alarm list indication
Monthly report
Energy monitoring
data etc.
Touch
screen
controller
Side remote
controller
Mini-SMMS
Master remote
controller
Weekly timer
RBC-EXW21E2
Remote location
ON/OFF control board
TCB IPCB-4E
"1:1model" connection
interface
TCB-PCNT30TLE2
Wired remote controller
RBC-AMT31E
Simple remote controller Wireless remote
RBC-AS21E2
controller
Super Modular Multi Outdoor Unit
Super Digital Inverter
Digital Inverter
Outline of application Control
12-1. Applications
12-1-1. Applications for indoor remote controller
Basic function
System diagram
Model
Wired remote controller
RBC-AMT31E
Main remote controller
Simple remote controller
RBC-AS21E2
Indoor
unit
Possible up to Max.
total length 500m
Remote
controller
1-1
Wireless remote controller
kit
TCB-AX21U(W)-E2
RBC-AX22CE2
TCB-AX21E2
Individual
control
Air conditioner is
individually operated
at a distance.
Wireless remote controller
Indoor
unit
(((
Receiver unit
Wireless
Remote
controller
Wired remote controller
RBC-AMT31E
Max.8 indoor units
Simple remote controller
RBC-AS21E2
GROUP control
1-2
One remote controller
can control a group of
up to a maximum. 8
indoor units.Operating
on the same setting
Indoor
unit
Indoor
unit
Indoor
unit
Remote
controller
Possible up to Max.total length 500m
12 -2
Indoor
unit
Basic function
System diagram
Model
Wired remote controller
RBC-AMT31E
Wired system
Simple remote controller
RBC-AS21E2
Indoor
unit
Remote
controller
Remote
controller
Master
Side
Wireless remote controller
kit
TCB-AX21U(W)-E2
RBC-AX22CE2
TCB-AX21E2
Possible up to Max.
total length 500m
Two remote control
1-3
Wireless system
Air conditioner is
controlled by two
remote controllers in
two locations.
Indoor
unit
((
(((
(
Wireless
remote
controller 1
Wireless
remote
controller 2
Master
Side
Indoor
unit
((
(
Wired & Wireless
combination control
(Either one of the
two controllers can
be set as side control).
Remote
controller
Wireless
remote
controller
Weekly timer function
Setting of ON-OFF
3 times par day
Timer operation time is displayed.
Holiday period
1-4
Control by
weekly timer
+
Weekly timer
RBC-EXW21E2
Indoor
unit
Weekly schedule
operation
Remote
controller
Wired remote controller
RBC-AMT31E
Weekly
timer
12 -3
12-1-2. Application controls for central remote controller
Basic function
System diagram
Model
Central remote controller
TCB-SC642TLE2
Mini-SMMS
Outdoor unit
Line-3
Indoor unit
U3, U4
Indoor remote controller
Wired remote controller
RBC-AMT31E
U1, U2
Zone
4
Indoor remote controller
U3, U4
U5, U6
Outdoor unit
Super MMS
Line-2
Indoor unit
Simple remote controller
RBC-AS21E2
U1, U2
Zone
3
Zone
2
Indoor remote controller
Outdoor unit
U3, U4
Mini-SMMS
Indoor unit
Line-1
2-1
Central management
controller for 64 units
U1, U2
Zone
1
PMV Kit
Indoor remote controller
Power
Central
supply
remote controller
Single phase
220/230/240V
Function of central remote controller
Individual control for up to 64 indoor units.
Individual control for max. 64 indoor units divided in to
4 zones. (Up to 16 indoor units for each zone.)
Up to 16 outdoor header units are connectable.
4 specific central control settings to restrict individual
operation by remote controller are selectable.
Different settings for one of 1 to 4 zones.
Usable with other central control devices
(Up to 10 central control devices in one control circuit)
Two selectable control modes
Central controller mode/Remote controller mode
Setting of simultaneous ON/OFF 3 times per day
when a controller is combined with using a weekly
timer.
U3, U4
2-2
Central remote
controller
+
Weekly timer
Weekly operation
schedule
can be set by
connecting a weekly
timer to the central
remote controller
Central remote controller
TCB-SC642TLE2
Outdoor unit
Indoor unit
U1, U2
+
Weekly timer
RBC-EXW21E2
PMV Kit
Indoor remote controller
Indoor remote controller
Single phase
220/230/240V
Power
supply
Weekly timer
Central
remote controller
12 -4
Wired remote controller
RBC-AMT31E
or
Simple remote controller
RBC-AS21E2
Basic function
System diagram
Model
Central remote controller
TCB-SC642TLE2
Indoor remote controller
Wired remote controller
RBC-AMT31E
U3, U4
Outdoor unit
U1, U2
Power
supply
Indoor unit
PMV Kit
Central remote controller
Single phase
220/230/240V
Even when grouping operation is performed
by connecting multiple indoor units to 1 line,
the indoor remote controller is required.
2-3
Central remote
controller without
indoor remote
controller
Example of grouping operation
U3, U4
Power
supply
Outdoor unit
U1, U2
(Group)
Indoor remote controller
is required
Central remote controller
PMV Kit
Available
Single phase
220/230/240V
U3, U4
Outdoor unit
U1, U2
Power
supply
PMV Kit
(Group)
Available
Central remote controller
Single phase
220/230/240V
12 -5
Basic function
System diagram
Model
Central remote controller
TCB-SC642TLE2
TCB-SC163TLE2
"1 : 1 model" connection
interface
TCB-PCNT30TLE2
RAV-SM560KRT-E,
SM800KRT-E are not
compatible to connect
Indoor remote controller
Wired remote controller
RBC-AMT31E
Power
supply
Central remote controller
Simple remote controller
RBC-AS21E2
U3, U4
2-4
Central management control with
"1 : 1 model"
Outdoor
unit
*1
U1, U2
PMV Kit
Indoor unit
Indoor remote controller
"1:1 model"
connection interface
* TOSHIBA Digital Inverter System and Super Digital
Inverter System
12 -6
12-1-3. Application control for network
Basic function
System diagram
Model
LN interface
TCB-IFLN640TLE
"1 : 1 model" connection
interface
TCB-PCNT30TLE2
RAV-SM560KRT-E,
SM800KRT-E are not
compatible to connect
Indoor remote controller
Wired remote controller
RBC-AMT31E
or
Simple remote controller
RBC-AS21E2
LON Center
LON WORKS
LN Interface
TCB-
3-1
LONWORKS
(*1)
R
Outdoor
unit
*1
PMV Kit
Remote controller
"1:1 model"
connection interface
*1 TOSHIBA Digital Inverter System and Super Digital
Inverter System
The LONWORKS interface should be connected
between a building management computer and a
Mini-SMMS / Super HRM / Super MMS system.
Max. 64 indoor units are connectable per interface.
*1) LONWORKS : Registerd trademark Echelon corporation.
12 -7
Basic function
System diagram
Model
BACnet server
BMS-LSV4E
BACnet server software
XXX-XXXXXX
TCS-Net Relay Interface
BMS-IFLSV1E
"1 model" connection
interface
TCB-PCNT30TLE2
RAV-SM560KRT-E,
SM800KRT-E are not
compatible to connect.
BAC net center
BAC net
server
TCB-
Indoor remote controller
Wired remote controller
RBC-AMT31E
TCN-NET
relay interface
Outdoor
unit
*1
Simple remote controller
RBC-AS21E2
PMV Kit
Remote controller
3-2
"1:1 model"
connection interface
BACnet R
(*1)
TOSHIBA Digital Inverter System and Super Digital
Inverter System
The local server should be connected to the BACnet
network and the Mini-SMMS and Super MMS
Super HRM system will be connected through the
interface.
*1) BACnetTM: ANSI/ASHRAE 135-1995, A Data Communication Protocol for Building Automation and Control Networks.
12 -8
12-1-4. Touch screen controller system
System diagram
Setup file
(record in
CF card)
Touch Screen
Controller
Intelligent Server
Intelligent Server Software
Max. 64
indoor units
Max. 16
Refrigerant
systems
per TCSNET relay
interface
Ethernet
connection
RS-485
TCS-Net Relay Interface
Switching HUB
(Local Supply)
Control Maximum
512 indoor units
Control wiring
Control wiring
Maximum 4
Intelligent server
PC for Energy
Monitoring
(Local supply)
RS-485
Control wiring
Report Creation
software
(Excel macro)
Maximum 8 TCS-NET Relay Interface
RS-485
(Note)
Switching HUB (10BASE-T compliant) is required
when using two or more intelligent servers or when
connecting a PC for energy monitoring and billing.
Maximum 4 Energy
Monitoring
Relay Interface
Energy Meter Relay Interface
1kWh/pulse
or 10kWh/pulse
50-1000ms
Maximum 8 digital inputs
I/F
Maximum
4 digital outputs
Digital I/O Relay Interface
Function
Devices
Model Name
Touch Screen controller
(English version)
Intelligent Server
Intelligent Server Software
TCS-Net Relay Interface
Energy Monitoring Relay Interface
Digital I/O Relay Interface
(1) Monitoring air-conditioners
Model Name
BMS-TP0640ACE
BMS-TP5120ACE
BMS-TP0640PWE
BMS-TP5120PWE
BMS-LSV4E
BMS-STCC01E
BMS-IFLSV1E
BMS-IFWH3E
BMS-IFDD01E
Max. 32 (8 X 4)
power meter
per intelligent
server
Maximum 8 Power Meter
Maximum 4 Digital
I/O Relay Interface
3-3
Fire alarm
Door Key Entry ON/OFF
Error code output
Local supply
Pulse Signal
I/F
RS-485
[ Power meter ]
Max. 32 (8 X 4)
digital inputs
Max. 16 (4 X 4)
digital outputs
per intelligent
server
Specification
Max 64 indoor units , without energy monitoring and billing
Max 512 indoor units , without energy monitoring and billing
Max 64 indoor units , with energy monitoring and billing
Max 512 indoor units , with energy monitoring and billing
Server in between Touch Screen controller and RS-485
Installed on Intelligent Server
Interface between intelligent Server Control wiring(TCC-LINK)
Interface for power meter
Interface for input / output signal
Operation status can be viewed according to a unit.
[Unit] All building, All tenants, Each tenant, Each area, Each remote controller group
[Monitoring contents] Operation and alarm status, Setting status for each remote controller group
(2) Operating of air-conditioners
Header / individual control can be performed according to a unit.
[Operating contents] ON/OFF, Operation setting (operation mode, air volume,
louver position, setting temp., restricted setting from remote location)
(3) Schedule operation
Air-conditioners are operated according to the set-up schedule / operation pattern.
Schedule opretaion can be performed according to a unit.
[Operation pattern] Weekly pattern, special day pattern (4 pattern), Non-operation days pattern
(4) Alarm list display
The present alarm contents are displayed.
[Display contents] Alarm contents, Unit number, Generated time
(5) Alarm record display
The alarm history records are displayed.
[Display contents] Alarm contents, Unit number, Generated time
(6) Monthly report data extraction
Monthly report data is written to "Compact Flash". Monthly reports can be created according to
a unit using the monthly report software.
[Monthly report contents] The number of ON/OFF, Operating time, Results of energy monitoring
(7) Energy monitoring data extraction Power consumption data is written to "Compact Flash". Energy monitoring can be performed
according to a unit using the energy monitoring software.
[Energy monitoring data] Power consumption according to the power meter
12 -9
12-2. Controller dimensions
Wired remote controller
RBC-AMT31E
120
120
84
18
62
16
Note : All dimensions are in mm
Simple remote controller
120
80
RBC-AS21E2
13
60
70
16
Note : All dimensions are in mm
12 -10
Wireless remote controller kit
TCB-AX21U (W)-E2
186
19.5
177
186
58
32
61
Note : All dimensions are in mm
RBC-AX22CE2
130
19.5
177
65
58
61
Note : All dimensions are in mm
12 -11
Wireless remote controller kit
TCB-AX21E2
58
19.5
83.5
177
83.5
4.4 x 9.4 long hole
13
70
4.4 x 5.4 long hole
61
Note : All dimensions are in mm
Weekly timer
RBC-EXW21E2
120
2.7
4
16
120
Note : All dimensions are in mm
12 -12
ON-OFF controller
116
TCB-CC163TLE2
Unit: mm
160
(6)
148
14
69
115
121
148
(6)
160
6
6
Z
122
4-Ø5 diameter holes
(for mounting)
128
Hole for electrical wiring
47
80
128
36
13
80
4-Ø5.5 diameter holes (for mounting)
Z-view (back side)
12 -13
Note : All dimensions are in mm
Remote sensor
80
120
TCB-TC21LE2
13
60
70
16
Note : All dimensions are in mm
Central remote controller
TCB-SC642TLE2
160
148
21
69
Z
115
(6)
121
6
148
(6)
160
6
13
15
116
47
121
47
80
128
36
13
128
80
Z view (back side)
12 -14
Note : All dimensions are in mm
TCS-Net relay interface
BMS-IFLSV1E
200
6- 5.5 mounting holes
78
22
22
78
78
22
66
63.6
156
170
78
146.9
22
Note : All dimensions are in mm
Touch screen controller
BMS-TP0640ACE
BMS-TP5120ACE
BMS-TP0640PWE
BMS-TP5120PWE
256
91.75
70
99.3
75
242
95.75
75
302
55.5
19 30
82.5
48
16
5
316
249
54
49
Note : All dimensions are in mm
12 -15
Intelligent server
39
CAUTION
Do not remove.
198
BMS-LSV2E
370
WARNING
Do not decompose.
Note : All dimensions are in mm
Energy monitoring relay interface/Digital I/O relay interface
BMS-IFWH3E
BMS-IFDD01E
18
18
234
Grommet for
power input
92.5
(193)
103.5
Grommet for
power meter
18
18
53.5
64.5
Grommet for
RS-485
63.6
220
246
Note : All dimensions are in mm
12 -16
LON GATEWAY
TCB-IFLN640TLE
Mounting hole 6-O
/ 5.5
18
18
78.5
78.5
193
78.5
78.5
18
18
234
66
63.6
220
246
Note : All dimensions are in mm
12 -17