Download Super-MMS - Home E-shop
Transcript
Super-MMS Super Modular Engineering Data Book Multi System 1 Foreword Foreword 1 The engineering data book details all relevant data, charts and drawings to enable you to get the best performance from the Toshiba Super Modular Multi System for the various applications. The information is aimed to assist you by providing greater detail of the system and the wider applications that the system will cover. It is recommended the use of the data book is used in accordance with the following as references. Design manual : File No.A03-008 Installation manual : File No.A03-012 Service manual : File No.A03-009 1 2 2 Contents 1 2 3 4 5 6 7 8 Foreword Foreword .................................................................. 1 Contents ................................................................... 2 Introduction .............................................................. 5 System overview .........................................................9 Capacity compensation chart .....................................21 Piping requirements ...................................................29 Refrigerant cycle diagram ..........................................35 Sensible capacity table ..............................................45 Part load performance ...............................................71 10 Wiring guideline ........................................................85 11 Wiring diagram .......................................................... 95 9 A. Connection schematic (field wiring) B. Inner circuit 12 Controls ...................................................................111 13 Fan characteristics ..................................................133 A. Static pressure B. Air velocity profile (Air throw distance chart) 14 Sound characteristics (NC curve) .............................143 15 Dimensional drawing ...............................................163 A. Indoor units B. Outdoor units 16 Specifications ..........................................................189 1. 50Hz models 2. 60Hz models Appendix High Wall Type (2 series) 1-Way Air Discharge Cassette Type (2 series) Slim Duct Type 2 3 Introduction 3 4 3 Introduction Foreword , World s Best Technology for Energy Saving System Toshiba has attained the pinnacle of world technology in all aspects of efficiency, durability, and comfort. 3 New large diameter propeller fan (Flash wing fan) High performance new bell mouth (Smooth bell mouth) Enlarged suction R Reversed circular blade Enlarged suction R allows smoother flow. Enlarged fan diameter The reversed circular form reduces the interference of the flow between the blades, and the backward vortex. High efficiency DC fan motor High output/ high efficiency DC motor High efficiency heat transfer pipe R410A + Output 600W + Sine wave drive Configuration of heat transfer pipe AI dual inverter system High speed calculation vector control inverter High efficiency DC twin rotary compressor , World s first core technology: each module (singular outdoor unit) is installed with two (dual) DC twin rotary compressors that work effectively with the highly efficient refrigerant R410A. The system operates in the most optimum pattern for both energy saving and reliability. -Installation Work: Less Piping Material and Higher Efficiency Cost Saving of Piping Material Less piping work Efficient Installation Work Smaller piping diameters than ever before. This is due to the all inverter type dual compressors, Automatic configuration of outdoor unit. Improved reliability with identical casing Each outdoor unit (1 module) is of the same size and design. Therefore the basic installation work will be identical. The unit has been designed for your convenience, so it is possible to fit the unit comfortably into a standard size elevator. Automatic low-noise mode, only possible where dual inverter type compressors are used. Froom the weather data of the Japanese Mechanical and Electrical Engineers building in the year 2000. Tokyo (8:00 21:00) remote control temperature setting at 27 Outside noise(dB) Time generated (Hours/year) 300 60 Time generated Outdoor unit noise 250 55 Automatic low noise mode 200 150 50 45 100 40 50 17 20 25 35 30 35 38 Outside temperature(oC ) * All our compressors are inverter type Numbers used are expected numbers. 5 COP 3 High efficiency DC twin rotary compressor Super-MMS (410A) *1 DC twin rotary compressors are most congenial with R410A and are used within the outdoor units. (Conversion to all inverter type) DC fan motor 10HP System 3.80 20HP System 3.55 Leading the world with high efficiency and high COP in both 1:1 system and VRF system. *1 Super-MMS (8HP) 4.10 high-level DC twin rotary compressor installed on all the outdoor units for combined use!(Conversion to all inverter type) Oil control is the key to the reliability. Flexible to meet the sophisticated condition of buildings or various customer requirements Top Top Outlet disk compressor unit -Design Work: High-speed Calculation Vector Control Inverter Active oil control Large space The longest piping in the industry enabling a flexible floor design. motor Bottom 1) Max Equivalent Length 175m (Max Actual Length 150m) roller oil flow Weight 67% Volume 61% Congenial with high pressure refrigerant R410A Force on the vertical shaft (roller) is small. Range of rotation 15-120rps Compressor efficiency See diagram on the right Oil discharge 1/40 (Compared with the conventional unit) (ratio) Comparison of compressor efficiencies Total compressor efficiency (%) (Compared with the conventional unit) 8 storey building can be covered by one piping system. 4)Max from 1st Branch 65m Compression structure by the rotation of the rollers inside the fixed cylinder allows the easy supply of oil to the swaying surface. The compressing rollers move in the same direction as the rotary shaft. This creates a force in the direction of compression even at high compression. Thus high efficiency and reliability are attained. 3)Max Indoors Difference 30m 2)Height Difference - Upper Outdoor Unit - Lower Outdoor Unit 50m oil TOSHIBA 1 Piping System, 30m (8 floors) This difference is the energy saving Tw i Sc 20 40 ro n 1) ro t ar Max Equivalent Length y ll Super MMS 60 80 Max Actual Length 2) 3) 4) Height Difference Upper Lower Outdoor Unit Outdoor Unit Max Indoors Difference Max from 1st Branch Total Extension 30m 65m 300m 48units 175m 150m 50m 40m Max Connectable Indoor Units Super MMS enable flexible branching. 100 Rotation(rps) You may change branching at installation sites. (of the conventional unit) Super MMS can quickly satisfy such "Header branch after Y joint" a requirement as addition of extra according to original plan, but .... indoor unit(s)... Unique Therefore, all the compressor units can operate equally. Y joint technology Y joint Header branch Header branch Y joint Addition of extra indoor unit e.g. in case of a workload of 2 compressor units; Super MMS ON ON OFF ON OFF 1 2 3 4 INV Comp Master/Follower Part load COP Compressor start ON INV Comp INV Comp INV Comp No Need Higher COP Equal start chance As both heat exchangers on the 2 outdoor units are usable, higher energy-saving (higher efficiency) can be achieved. High level, Energy saving VRF System The sequence of the first compressors start up, changes whenever switching on. Super MMS will offer the best solution for the customers requirements as well as consideration of ecology, with the unique technologies and advantages. today 1 3 4 2 tomorrow the day after tomorrow 2 4 3 1 1 2 3 4 Through avoiding concentration of the load at an individual unit, prevention of failure and improvement of reliability are achieved. 6 Easy "Y joint branch after header branch" solution in this example. 4 System overview 7 8 4 System overviewForeword 1. OUTLINE OF TOSHIBA SUPER MMS (Super Modular Multi System) Shortest route design by free branching 4 The Combination of line and header branching is highly flexible. Following the shortest design route possible, thereby saving on installation time and cost. Line/header branching after the header branching is only available with TOSHIBA Super MMS. Line branching Outdoor unit Branching joint 8F Indoor unit Header branching Outdoor unit 7F Branching header Indoor unit Line + Header branching Outdoor unit Header 2F Branching joint Indoor unit Line branching after header branching Outdoor unit Header 1F Branching joint Super MMS MMS Only Only Indoor unit Header branching after header branching Outdoor unit Header Super MMS Only Header Indoor unit 9 Non-polarized control wiring between the outdoor and indoor units 4 Outdoor unit U1 U2 Indoor unit U1 U2 U1 U2 U1 U2 Wiring diagnosis system 8F Use the switches on the micro processor P.C.B of the outdoor unit. Detect wiring to the indoor unit b4 which should not be in system A. b4 is missing in the system B. Piping A system Outdoor unit a1 a2 Wiring B system a3 a4 Indoor unit Outdoor unit b1 b2 b3 b4 7F Height difference between indoor unit and indoor unit : 30m 2F Height difference between indoor unit and outdoor unit : 50m Outdoor unit Allowable pipe length : 175m equivalent length 1st branching section From 1st branching to the furthest indoor unit : 65m 1F 10 Compact design The design of the modular TOSHIBA Super MMS outdoor unit allows for easy manoeuvering of the unit. The unit will fit into any standard size lift. The compactness of the unit allows for it to be installed into a limited space. Largest system capacity 4 TOSHIBA Super MMS can be combined up to 48 HP (135kW) as one refrigerant system. Energy saving No. 1 COP in VRF industry. Compared with a conventional chiller fan coil system a large energy saving can be achieved. Advanced bus communication system Wiring between indoor and outdoor units is a simple 2 core wire system. Communication of addresses is also automatically configured. A default test mode operation is available. Self diagnostics system Comprehensive troubleshooting codes allows for a timely identification of possible problems arising. High lift design Equivalent pipe length of 175m and vertical lift of 50m is possible with TOSHIBA Super MMS. The maximum vertical lift between indoor units is 30m, this being the highest in the industry. This allows for greater flexibility within the building design of the system. Multiplied indoor units Indoor units with different capacities and configurations can be combined up to a maximum of 135% of the outdoor units capacity. A maximum of 48 indoor units can be combined with the 30 _ 48 HP outdoor units. Intelligent control TOSHIBA Super MMS intelligent controls and modulating valves deliver the required capacity, according to the load variation from 50% to 100%. The intelligent controls and modulating valves limit or increase the cooling capacity dynamically so humidity and temperature are kept within the comfort zone. Conforms to building control law IAQ (Indoor Air Quality) is also achieved by combining various accessories required by the Building Control Law. Wide control applications Artificial Intelligence Network system. Central control and monitoring system available. Weekly schedule operation through weekly timer. Integration with Building Management System (BMS) is available. 11 2. SUMMARY OF SYSTEM EQUIPMENTS Equipment 1. Outdoor units Inverter unit Corresponding HP 4 5 HP 6 HP 8 HP 10 HP Appearance 12 HP Heat pump MMY- MAP0501HT8 MAP0601HT8 MAP0801HT8 MAP1001H8 MAP1201HT8 Model Heat pump MMY- MAP0501HT7 MAP0601HT7 MAP0801HT7 MAP1001HT7 MAP1201HT7 name Cooling only MMY- MAP0501T8 MAP0601T8 MAP0801T8 MAP1001T8 MAP1201T8 Cooling capacity (kW) 14.0 16.0 22.4 28.0 33.5 Heating capacity (kW) 16.0 18.0 25.0 31.5 37.5 2. Outdoor units (Combination of outdoor units) Corresponding HP 5 HP 6 HP 8 HP 10 HP 12 HP MMY- MAP0501HT8 MAP0601HT8 MAP0801HT8 MAP1001HT8 MAP1201HT8 MMY- MAP0501HT7 MAP0601HT7 MAP0801HT7 MAP1001HT7 MAP1201HT7 MMY- MAP0501T8 MAP0601T8 MAP0801T8 MAP1001T8 MAP1201T8 Cooling capacity(kW) 14.0 16.0 22.4 28.0 33.5 Heating capacity(kW) 16.0 18.0 25.0 31.5 37.5 5 HP 6 HP 8 HP 10 HP 12 HP Combined outdoor units Combined Model No. of connectable indoor units 8 Corresponding HP 22 HP MMY- AP2211HT8 MMY- AP2211HT7 MMYAP2211T8 Cooling capacity(kW) 61.5 Heating capacity(kW) 69.0 12 HP 10 HP Combined outdoor units Combined Model No. of connectable indoor units 16 HP AP1601HT8 AP1601HT7 AP1601T8 45.0 50.0 8 HP 8 HP 18 HP AP1801HT8 AP1801HT7 AP1801T8 50.4 56.5 10 HP 8 HP 20 HP AP2001HT8 AP2001HT7 AP2001T8 56.0 63.0 10 HP 10 HP 22 HP AP2201HT8 AP2201HT7 AP2201T8 61.5 69.0 8 HP 8 HP 6 HP 10 13 16 20 23 27 30 33 37 24 HP AP2401HT8 AP2401HT7 AP2401T8 68.0 76.5 8 HP 8 HP 8 HP 24 HP AP2411HT8 AP2411HT7 AP2411T8 68.0 76.5 12 HP 12 HP 26 HP AP2601HT8 AP2601HT7 AP2601T8 73.0 81.5 10 HP 8 HP 8 HP 28 HP AP2801HT8 AP2801HT7 AP2801T8 78.5 88.0 10 HP 10 HP 8 HP 30 HP AP3001HT8 AP3001HT7 AP3001T8 84.0 95.0 10 HP 10 HP 10 HP 32 HP AP3201HT8 AP3201HT7 AP3201T8 90.0 100.0 8 HP 8 HP 8 HP 8 HP 32 HP AP3211HT8 AP3211HT7 AP3211T8 90.0 100.0 12 HP 10 HP 10 HP 34 HP AP3401HT8 AP3401HT7 AP3401T8 96.0 108.0 10 HP 8 HP 8 HP 8 HP 34 HP AP3411HT8 AP3411HT7 AP3411T8 96.0 108.0 12 HP 12 HP 10 HP 48 48 37 Corresponding HP 36 HP MMY- AP3601HT8 Combined MMY- AP3601HT7 Model MMYAP3601T8 101.0 Cooling capacity(kW) 113.0 Heating capacity(kW) 10 HP 10 HP Combined outdoor units 8 HP 8 HP No. of connectable 48 indoor units 14 HP AP1401HT8 AP1401HT7 AP1401T8 38.4 43.0 8 HP 6 HP 40 40 43 47 48 48 48 36 HP AP3611HT8 AP3611HT7 AP3611T8 101.0 113.0 12 HP 12 HP 12 HP 38 HP AP3801HT8 AP3801HT7 AP3801T8 106.5 119.5 10 HP 10 HP 10 HP 8 HP 40 HP AP4001HT8 AP4001HT7 AP4001T8 112.0 126.5 10 HP 10 HP 10 HP 10 HP 42 HP AP4201HT8 AP4201HT7 AP4201T8 118.0 132.0 12 HP 10 HP 10 HP 10 HP 44 HP AP4401HT8 AP4401HT7 AP4401T8 123.5 138.0 12 HP 12 HP 10 HP 10 HP 46 HP AP4601HT8 AP4601HT7 AP4601T8 130.0 145.0 12 HP 12 HP 12 HP 10 HP 48 HP AP4801HT8 AP4801HT7 AP4801T8 135.0 150.0 12 HP 12 HP 12 HP 12 HP 48 48 48 48 48 48 48 3. Branching joints and headers Y-shape branching joint (*3) 4-branching header (*4) 8-branching header (*4) (*5) T-shape branching joint (For connection of outdoor units) 12 *12 *3 *4 *5 *6 * Model name RBM-BY53E RBM-BY103E RBM-BY203E RBM-BY303E RBM-HY1043E RBM-HY2043E RBM-HY1083E RBM-HY2083E RBM-BT13E Usage Indoor unit capacity code (*1) : Total below 6.4 Indoor unit capacity code (*1) : Total 6.4 or more and below 14.2 (*2) Indoor unit capacity code (*1) : Total 14.2 or more and below 25.2 (*2) Indoor unit capacity code (*1) : Total 25.2 or more (*2) Indoor unit capacity code (*1) : Total below 14.2 Max.4 Indoor unit capacity code (*1) : Total 14.2 or more and below 25.2 branches Indoor unit capacity code (*1) : Total below 14.2 Max.8 Indoor unit capacity code (*1) : Total 14.2 or more and below 25.2 branches 1 set of 3 types of T-shape joint pipes as described below: The required quantity is arranged and they are combined at the site. Connection piping Corresponded dia. (mm) o/9.5 Balance pipe o/9.5 to o/22.2 Piping at liquid side Piping at gas side o/15.9 to o/41.3 Appearance Qty 1 1 1 ‘‘Capacity code’’ can be obtained. (Capacity code is not actual capacity) If total capacity code value of indoor unit exceeds that of outdoor unit, apply capacity code of outdoor unit. When using Y-shape branching joint for 1st branching, select according to the capacity code of the outdoor unit. Max. capacity code of 6.0 in total can be connected. If capacity code of outdoor unit is 26 or more, it is not used for 1st branching. Model names for outdoor and indoor units described in this guide are shortened because of the space constraint. Cooling Only model 50Hz Super Modular Multi System Outdoor Unit : List of Product and Combined Model Name HP No. of (Capacity Model name combined MMYcode) units Inverter 5 HP MMY- Used Qty 5HP ( 5) MAP0501T8 1 MAP0501T8 1 6HP ( 6) MAP0601T8 1 8HP ( 8) MAP0801T8 1 10HP (10) MAP1001T8 1 12HP (12) MAP1201T8 1 14HP (14) AP1401T8 2 16HP (16) AP1601T8 18HP (18) AP1801T8 20HP (20) AP2001T8 2 22HP (22) AP2201T8 3 22HP (22) AP2211T8 2 24HP (24) AP2401T8 3 24HP (24) AP2411T8 2 26HP (26) AP2601T8 28HP (28) 30HP (30) Inverter 6 HP MMY- Used Qty MAP0601T8 1 MAP0601T8 Inverter 8HP MMY- Used Qty MAP0801T8 1 MAP0801T8 1 2 MAP0801T8 2 2 MAP0801T8 1 MAP0601T8 1 Inverter 10HP MMY- Used Qty MAP1001T8 1 MAP1001T8 1 MAP1001T8 2 MAP1001T8 1 MAP0801T8 2 MAP0801T8 3 3 MAP0801T8 2 MAP1001T8 1 AP2801T8 3 MAP0801T8 1 MAP1001T8 2 AP3001T8 3 MAP1001T8 3 32HP (32) AP3201T8 4 32HP (32) AP3211T8 3 MAP1001T8 2 34HP (34) AP3401T8 4 MAP1001T8 1 34HP (34) AP3411T8 3 36HP (36) AP3601T8 4 36HP (36) AP3611T8 3 38HP (38) AP3801T8 4 40HP (40) AP4001T8 42HP (42) AP4201T8 44HP (44) 1 Inverter 12HP MMY- Used Qty MAP1201T8 1 MAP1201T8 1 MAP1201T8 2 MAP1201T8 1 MAP1201T8 2 MAP1201T8 3 MAP0801T8 4 MAP0801T8 3 MAP1001T8 1 MAP0801T8 2 MAP1001T8 2 MAP0801T8 1 MAP1001T8 3 4 MAP1001T8 4 4 MAP1001T8 3 MAP1201T8 1 AP4401T8 4 MAP1001T8 2 MAP1201T8 2 46HP (46) AP4601T8 4 MAP1001T8 1 MAP1201T8 3 48HP (48) AP4801T8 4 MAP1201T8 4 4 1. Allocation standard of model name MMY_ M AP T 8 Power supply specifications, 3O / 380_415 V, 50Hz ....... 8 T : Capacity variable unit Development series No. Capacity rank HP x 10 New refrigerant R410A M : Single module unit, No mark : Combined Model name Modular Multi 2. Range of combined capacity No. of combined units: 1 to 4 units Capacity of combined units: 14 HP (140 type) to 48 HP (480 type) 3. Rated conditions (Rated mode : Condition) Cooling: Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB 13 Heat Pump model 4 50Hz HP No. of (Capacity Model name combined MMYcode) units Inverter 5 HP MMY- Used Qty 5HP ( 5) MAP0501HT8 1 MAP0501HT8 1 6HP ( 6) MAP0601HT8 1 8HP ( 8) MAP0801HT8 1 10HP (10) MAP1001HT8 1 12HP (12) MAP1201HT8 1 Inverter 6 HP MMY- Used Qty MAP0601HT8 1 MAP0601HT8 Inverter 8 HP MMY- Used Qty MAP0801HT8 1 MAP0801HT8 1 2 MAP0801HT8 2 2 MAP0801HT8 1 14HP (14) AP1401HT8 2 16HP (16) AP1601HT8 18HP (18) AP1801HT8 20HP (20) AP2001HT8 2 22HP (22) AP2201HT8 3 22HP (22) AP2211HT8 2 24HP (24) AP2401HT8 3 24HP (24) AP2411HT8 2 26HP (26) AP2601HT8 28HP (28) 30HP (30) MAP0601HT8 1 Inverter 10 HP MMY- Used Qty MAP1001HT8 1 MAP1001HT8 1 MAP1001HT8 2 MAP1001HT8 1 MAP0801HT8 2 MAP0801HT8 3 3 MAP0801HT8 2 MAP1001HT8 1 AP2801HT8 3 MAP0801HT8 1 MAP1001HT8 2 AP3001HT8 3 MAP1001HT8 3 32HP (32) AP3201HT8 4 32HP (32) AP3211HT8 3 34HP (34) AP3401HT8 4 34HP (34) AP3411HT8 3 36HP (36) AP3601HT8 4 36HP (36) AP3611HT8 3 38HP (38) AP3801HT8 4 40HP (40) AP4001HT8 42HP (42) 1 Inverter 12 HP MMY- Used Qty MAP1201HT8 1 MAP1201HT8 1 MAP1201HT8 2 MAP1201HT8 1 MAP1201HT8 2 MAP1201HT8 3 MAP0801HT8 4 MAP0801HT8 3 MAP1001HT8 1 MAP0801HT8 2 MAP1001HT8 2 MAP0801HT8 1 MAP1001HT8 3 4 MAP1001HT8 4 AP4201HT8 4 MAP1001HT8 3 MAP1201HT8 1 44HP (44) AP4401HT8 4 MAP1001HT8 2 MAP1201HT8 2 46HP (46) AP4601HT8 4 MAP1001HT8 1 MAP1201HT8 3 48HP (48) AP4801HT8 4 MAP1201HT8 4 MAP1001HT8 2 MAP1001HT8 1 1. Allocation standard of model name MMY_ M AP H T 8 Power supply specifications, 3O / 380_415 V, 50Hz ....... 8 T : Capacity variable unit H : Heat pump Development series No. Capacity rank HP x 10 New refrigerant R410A M : Single module unit, No mark : Combined Model name Modular Multi 2. Range of combined capacity No. of combined units: 1 to 4 units Capacity of combined units: 14 HP (140 type) to 48 HP (480 type) 3. Rated conditions (Rated mode : Condition) Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB/6oC WB 14 Heat Pump model 60Hz Super Modular Multi System Outdoor Unit : List of Product and Combined Model Name HP No. of (Capacity Model name combined MMYcode) units Inverter 5 HP MMY- Used Qty 5HP ( 5) MAP0501HT7 1 MAP0501HT7 1 6HP ( 6) MAP0601HT7 1 8HP ( 8) MAP0801HT7 1 10HP (10) MAP1001HT7 1 12HP (12) MAP1201HT7 1 14HP (14) AP1401HT7 2 16HP (16) AP1601HT7 18HP (18) AP1801HT7 20HP (20) AP2001HT7 2 22HP (22) AP2201HT7 3 22HP (22) AP2211HT7 2 24HP (24) AP2401HT7 3 24HP (24) AP2411HT7 2 26HP (26) AP2601HT7 28HP (28) 30HP (30) Inverter 6 HP MMY- Used Qty MAP0601HT7 1 MAP0601HT7 Inverter 8 HP MMY- Used Qty MAP0801HT7 1 MAP0801HT7 1 2 MAP0801HT7 2 2 MAP0801HT7 1 MAP0601HT7 1 Inverter 10 HP MMY- Used Qty MAP1001HT7 1 MAP1001HT7 1 MAP1001HT7 2 MAP1001HT7 1 MAP0801HT7 2 MAP0801HT7 3 3 MAP0801HT7 2 MAP1001HT7 1 AP2801HT7 3 MAP0801HT7 1 MAP1001HT7 2 AP3001HT7 3 MAP1001HT7 3 32HP (32) AP3201HT7 4 32HP (32) AP3211HT7 3 34HP (34) AP3401HT7 4 34HP (34) AP3411HT7 3 36HP (36) AP3601HT7 4 36HP (36) AP3611HT7 3 38HP (38) AP3801HT7 4 40HP (40) AP4001HT7 42HP (42) AP4201HT7 1 Inverter 12 HP MMY- Used Qty MAP1201HT7 1 MAP1201HT7 1 MAP1201HT7 2 MAP1201HT7 1 MAP1201HT7 2 MAP1201HT7 3 MAP0801HT7 4 MAP0801HT7 3 MAP1001HT7 1 MAP0801HT7 2 MAP1001HT7 2 MAP0801HT7 1 MAP1001HT7 3 4 MAP1001HT7 4 4 MAP1001HT7 3 MAP1201HT7 1 44HP (44) AP4401HT7 4 MAP1001HT7 2 MAP1201HT7 2 46HP (46) AP4601HT7 4 MAP1001HT7 1 MAP1201HT7 3 48HP (48) AP4801HT7 4 MAP1201HT7 4 MAP1001HT7 2 MAP1001HT7 1 4 1. Allocation standard of model name MMY_ M AP H T 7 Power supply specifications, 3O / 380 V, 60Hz ....... 7 T : Capacity variable unit H : Heat pump Development series No. Capacity rank HP x 10 New refrigerant R410A M : Single module unit, No mark : Combined Model name Modular Multi 2. Range of combined capacity No. of combined units: 1 to 4 units Capacity of combined units: 14 HP (140 type) to 48 HP (480 type) 3. Rated conditions (Rated mode : Condition) Cooling : Indoor air temperature 27oC DB/19oC WB, Outdoor air temperature 35oC DB Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB/6oC WB 15 4. Indoor unit Type 4 4-way Air Discharge Cassette Type 2-way Air Discharge Cassette Type 1-way Air Discharge Cassette Type Slim Duct Type Concealed Duct Standard Type Concealed Duct High Static Pressure Type Under Ceilling Type 16-1 16 *1) China market only Appearance Model name MMU-AP0091H MMU-AP0121H MMU-AP0151H MMU-AP0181H MMU-AP0241H MMU-AP0271H MMU-AP0301H MMU-AP0361H MMU-AP0481H MMU-AP0561H MMU-AP0071WH MMU-AP0091WH MMU-AP0121WH MMU-AP0151WH MMU-AP0181WH MMU-AP0241WH MMU-AP0271WH MMU-AP0301WH MMU-AP0481WH*1) MMU-AP0071YH MMU-AP0091YH MMU-AP0121YH MMU-AP0151SH MMU-AP0181SH MMU-AP0241SH MMU-AP0152SH MMU-AP0182SH MMU-AP0242SH MMD-AP0071SPH MMD-AP0091SPH MMD-AP0121SPH MMD-AP0151SPH MMD-AP0181SPH MMD-AP0071SPH(SH)-C*1) MMD-AP0091SPH(SH)-C*1) MMD-AP0121SPH(SH)-C*1) MMD-AP0151SPH(SH)-C*1) MMD-AP0181SPH(SH)-C*1) MMD-AP0071SPH-K*3) MMD-AP0091SPH-K*3) MMD-AP0121SPH-K*3) MMD-AP0151SPH-K*3) MMD-AP0181SPH-K*3) MMD-AP0071BH MMD-AP0091BH MMD-AP0121BH MMD-AP0151BH MMD-AP0181BH MMD-AP0241BH MMD-AP0271BH MMD-AP0301BH MMD-AP0361BH MMD-AP0481BH MMD-AP0561BH MMD-AP0181H MMD-AP0241H MMD-AP0271H MMD-AP0361H MMD-AP0481H MMD-AP0721H MMD-AP0961H MMC-AP0151H MMC-AP0181H MMC-AP0241H MMC-AP0271H MMC-AP0361H MMC-AP0481H *2) European market only *3) Korea market only Cooling Heating Capacity rank Capacity code capacity (kW) capacity (kW) 009 012 015 018 024 027 030 036 048 056 007 009 012 015 018 024 027 030 048 007 009 012 015 018 024 015 018 024 007 009 012 015 018 007 009 012 015 018 007 009 012 015 018 007 009 012 015 018 024 027 030 036 048 056 018 024 027 036 048 072 096 015 018 024 027 036 048 type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type type 1.00 1.25 1.70 2.00 2.50 3.00 3.20 4.00 5.00 6.00 0.8 1.00 1.25 1.70 2.00 2.50 3.00 3.20 5.00 0.80 1.00 1.25 1.70 2.00 2.50 1.70 2.00 2.50 0.80 1.00 1.25 1.70 2.00 0.80 1.00 1.25 1.70 2.00 0.80 1.00 1.25 1.70 2.00 0.80 1.00 1.25 1.70 2.00 2.50 3.00 3.20 4.00 5.00 6.00 2.00 2.50 3.00 4.00 5.00 8.00 10.00 1.70 2.00 2.50 3.00 4.00 5.00 2.8 3.6 4.5 5.6 7.1 8.0 9.0 11.2 14.0 16.0 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 14.0 2.2 2.8 3.6 4.5 5.6 7.1 4.5 5.6 7.1 2.2 2.8 3.6 4.5 5.6 2.2 2.8 3.6 4.5 5.6 2.2 2.8 3.6 4.5 5.6 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 11.2 14.0 16.0 5.6 7.1 8.0 11.2 14.0 22.4 28.0 4.5 5.6 7.1 8.0 11.2 14.0 3.2 4.0 5.0 6.3 8.0 9.0 10.0 12.5 16.0 18.0 2.5 3.2 4.0 5.0 6.3 8.0 9.0 10.0 16.0 2.5 3.2 4.0 5.0 6.3 8.0 5.0 6.3 8.0 2.5 3.2 4.0 5.0 6.3 2.5 3.2 4.0 5.0 6.3 2.5 3.2 4.0 5.0 6.3 2.5 3.2 4.0 5.0 6.3 8.0 9.0 10.0 12.5 16.0 18.0 6.3 8.0 9.0 10.0 16.0 25.0 31.5 5.0 6.3 8.0 9.0 12.5 16.0 4. Indoor unit Type High Wall Type (1 series) High Wall Type (2 series) Floor Standing Cabinet Type Floor Standind Concealed Type Floor Standind Type *1) China market only Appearance Model name MMK-AP0071H MMK-AP0091H MMK-AP0121H MMK-AP0151H MMK-AP0181H MMK-AP0241H MMK-AP0072H*2) MMK-AP0092H*2) MMK-AP0122H*2) MML-AP0071H MML-AP0091H MML-AP0121H MML-AP0151H MML-AP0181H MML-AP0241H MML-AP0071H MML-AP0091H MML-AP0121H MML-AP0151H MML-AP0181H MML-AP0241H MMF-AP0151H MMF-AP0181H MMF-AP0241H MMF-AP0271H MMF-AP0361H MMF-AP0481H MMF-AP0561H *2) European market only *3) Korea market only Cooling Heating Capacity rank Capacity code capacity (kW) capacity (kW) 007 009 012 015 018 024 007 009 012 007 009 012 015 018 024 007 009 012 015 018 024 015 018 024 027 036 048 056 type type type type type type type type type type type type type type type type type type type type type type type type type type type type 0.80 1.00 1.25 1.70 2.00 2.50 0.80 1.00 1.25 0.80 1.00 1.25 1.70 2.00 2.50 0.80 1.00 1.25 1.70 2.00 2.50 1.70 2.00 2.50 3.00 4.00 5.00 6.00 2.2 2.8 3.6 4.5 5.6 7.1 2.2 2.8 3.6 2.2 2.8 3.6 4.5 5.6 7.1 2.2 2.8 3.6 4.5 5.6 7.1 4.5 5.6 7.1 8.0 11.2 14.0 16.0 2.5 3.2 4.0 5.0 6.3 8.0 2.5 3.2 4.0 2.5 3.2 4.0 5.0 6.3 8.0 2.5 3.2 4.0 5.0 6.3 8.0 5.0 6.3 8.0 9.0 10.0 16.0 18.0 4 16-2 17 5. Remote controller Name Model name Appearance Application 18 16-3 RBC-AMT21E/RBC-AMT31E RBC-AS21E/RBC-AS21E2 TCB-AX21U(W)-E TCB-AX21U(W)-E2 RBC-AX22CE RBC-AX22CE2 TCB-AX21E TCB-AX21E2 Wireless remote controller kit Simple wired remote controller 4 Wired remote controller Connected to indoor unit Function Start / Stop Mode Change Temperature setting Change of air flow Timer function 1 On or off timer operation, setting in 30 CODE No. SET DATA UNIT No. SETTING TEST R.C. No. UNIT SET Wired remote Wired remote controller controller (In case of control by 2 remote controllers) CL Connected to indoor unit TEST SETTING minute increments. Automatic Off function. 2 Combined with the weekly timer, weekly schedule operation can be operated. Filter sign Displays automatically maintenance time of indoor filter. Filter sign flashes. Self-diagnosis function Pressing‘‘CHECK’’ button displays cause of fault on the check code. Control by 2 remote controllers is available. Two remote controllers can be connected to one indoor unit. The indoor unit can be separately operated from a different location. Start / Stop Temperature setting Change of air flow Check code display ûC ûF Simple remote controller Connected to indoor unit Start / Stop Mode change Temperature setting Change of air flow Timer function On or off timer operation, setting in 30 minute increments. Automatic Off function. Control by 2 remote controllers is available. Two wireless remote controllers can operate one indoor unit. The indoor unit can be separately operated from a different location. Check code display TCB-AX21U(W)-E (for 4-way airdischarge cassette) RBC-AX22CE (for under ceiling) TCB-AX21-E (for other units except for the concealsed duct high static pressure) Name Model name Appearance Application Performance Connected to central remote controller or wired remote controller Weekly schedule operation 1 Setting different start / stop time for each day of the week 2 ON / OFF can be set 3 times a day. ON OFF ON RBC-EXW21E RBC-EXW21E2 Weekly timer 8:00 OFF ON 4 OFF 12:00 13:00 18:00 19:00 21:00 3 ‘‘CHECK’’ ‘‘PROGRAM’’ ‘‘DAY’’ SuMoTuWeTh Fr Sa Wired remote controller Weekly timer 4 Two different schedules for a week can be specified. (Summer schedule and winter schedule, etc.) PROGRAM1 ERROR PROGRAM2 button copying of setting easy. PROGRAM3 WEEKLY TIMER Outdoor unit 5 ‘‘CANCEL’’ ‘‘DAY’’ button enables holiday setting. 6 If power supply fails, the setting contents are stored in the memory for 100 hours. Weekly timer Central remote controller Connected to outdoor unit, indoor unit Header Follower Individual control up to 64 indoor units. Individual control for max. 64 indoor units divided into 4 zones. Up to 16 indoor units for each zone Up to 16 outdoor header units are connectable. Outdoor unit ZONE ALL ZONE GROUP TCB-SC642TLE TCB-SC642TLE2 Central remote controller 4 type central control setting to inhibit individual operation by remote controller can be selected. CODE No. 1234 SET DATA SETTING R.C. UNIT No. TEST No. GROUP SELECT ZONE CL Central remote controller Setting for one of 1 to 4 zones is available. Can be used with other central control devices (Up to 10 central control devices with in one control circuit) SET Two selectable control modes Central controller mode Remote controller mode Central remote controller Indoor remote controller Setting of simultaneous ON/OFF 3 times for each day of the week combined with a weekly timer. 1719 Name Model name Appearance Application Performance Connected to outdoor unit, indoor unit Header Follower Individual control up to 16 indoor units. Setting of simultaneous ON/OFF 3 times for each day of the week when combined with a weekly timer. Outdoor unit TCB-CC163TLE TCB-CC163TLE2 ON-OFF controller Connected to 2 remote controllers is possible. ON-OFF controller Outdoor unit ON-OFF controller Indoor remote controller 18 20 5 Capacity compensation chart 19 Foreword 20 5 Foreword Capacity compensation chart 3. Cooling/heating capacity characteristics 1. Cooling capacity calculation method : Required cooling capacity = Cooling capacity x Factor ( 1 , 2 , 3 , 4 , 5 *1) kW Capacity correction value 1 Indoor air wet bulb temperature vs. capacity correction value 1.2 1.1 5 1.0 0.9 0.8 20 15 24 Indoor air wet bulb temp. ( ) Capacity correction value 2 Outdoor air dry bulb temperature vs.capacity correction value 1.2 1.1 1.0 0.9 -5 0 5 10 15 20 25 30 35 Outdoor air dry bulb temp. ( ) 40 43 Capacity correction value 3 Air flow variation ratio of indoor unit vs. capacity correction (For concealed duct type only) 1.1 1.0 0.9 80 90 100 110 Air flow variation ratio (%) 120 *1 : Coefficient to use for the correction of the outdoor unit capacity when the total capacity of the indoor units are not equal to the outdoor unit capacity. 21 5 Outdoor unit (5 to 44HP) 75 76 78 80 82 84 86 88 90 92 94 %100 50 40 30 20 10 0 -10 -20 -30 -40 98 9 Height of outdoor unit H (m) Connecting pipe length and lift difference between indoor and outdoor units vs. capacity correction value 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 Pipe length (Equivalent length) L (m) Outdoor unit (46 to 48HP) ho l'o L' is the longest one of (l'o + l'a, l'o + l'b, l'o + l'c) 72 74 76 78 80 82 84 86 88 H = ho + (Largest one of ha, hb, and hc) 90 50 40 30 20 10 0 -10 -20 -30 -40 100% 98 96 94 92 Height of outdoor unit H (m) Outdoor unit hc hb ha l'a l'b l'c A B Indoor unit C 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 Pipe length (Equivalent length) L (m) Correction of outdoor unit diversity Correction (%) 120 100 80 60 40 20 0 20 40 60 80 100 120 135 Standard capacity ratio Indoor units total capacity ratio (%) *1 : Coefficient to use for the correction of the outdoor unit capacity when the total capacity of the indoor units are not equal to the outdoor unit capacity. 22 Foreword 2. Heating capacity calculation method: Required heating capacity = Heating capacity x Factor ( )kW Capacity correction value 1 Indoor air dry bulb temperature vs. capacity correction value 1.2 1.1 1.0 5 0.9 0.8 15 20 24 Indoor air dry bulb temp. ( ) Capacity correction value 2 Outdoor air wet bulb temperature vs. capacity correction value 1.2 1.1 1.0 0.9 0.8 0.7 0.6 0.5 -15 -10 -5 0 5 10 15 Outdoor air wet bulb temp. ( ) Capacity correction value 3 Air flow variation ratio of indoor unit vs. capacity correction (For concealed duct type only) 1.1 1.0 0.9 80 90 100 110 Air flow variation ratio (%) 120 *1 : Coefficient to use for the correction of the outdoor unit capacity when the total capacity of the indoor units are not equal to the outdoor unit capacity. 2 : Refer to item 3 * 23 Outdoor unit (5 to 48HP) 89 90 91 92 93 94 95 96 97 98 100% 50 40 30 20 10 0 -10 -20 -30 -40 9 5 Height of outdoor unit H (m) 4 Connecting pipe length and lift difference between indoor and outdoor units vs. capacity correction value 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 Pipe length (Equivalent length) L (m) Outdoor unit ho l'o L' is the longest one of (l'o + l'a, l'o + l'b, l'o + l'c) H = ho + (Largest one of ha, hb, and hc) hc hb ha l'a l'b l'c A B Indoor unit C 5 Correction of outdoor unit diversity 120 Correction (%) 100 80 60 40 20 0 20 40 60 80 100 120 135 Standard capacity ratio Indoor units total capacity ratio (%) *1 : Coefficient to use for the correction of the outdoor unit capacity when the total capacity of 24 the indoor units are not equal to the outdoor unit capacity. 3. Capacity correction in case of frost on the outdoor heat exchanger when in heating Correct the heating capacity when frost can be found on the outdoor heat exchanger. Heating capacity = Capacity after correction of outdoor unit x Correction value of capacity resulted from frost (Capacity after correction of outdoor unit : Heating capacity calculated in the above item 2.) Capacity correction value 6 Capacity correction in case of frost on the outdoor heat exchanger 1.0 5 0.9 0.8 -15 -10 -5 0 5 10 Outdoor air wet bulb temp. ( ) 4. Capacity calculation for each indoor unit Capacity for each indoor unit Required standard capacity of indoor unit = Capacity after correction of outdoor unit x Total value of standard indoor unit capacity 5. Operating temperature range In heating time In cooling time 20 Outdoor air wet bulb temp. ( ) 35 30 25 Continuously operable range 20 15 Usable range (in pull down) Outdoor air dry bulb temp. ( ) 40 10 5 0 15 10 5 Usable range (in warming-up) 45 0 -5 Continuously operable range -10 -15 -5 -10 10 -20 15 20 25 28 Indoor air wet bulb temp. ( ) 30 5 10 15 20 25 30 Indoor air dry bulb temp. ( ) * The unit can be operated even if outdoor tem- 6. Rated conditions Cooling : Indoor air temperature 27 Heating : Indoor air temperature 20 perature gets down to -20 . However, note that the warranty covers only up to -15 because operation beyond that temperature is out of specification. * When outdoor air temperature falls below -15 , it may cause shortening of the products lifetime. DB/19.0 WB, Outdoor air temperature 35 DB DB, Outdoor air temperature 7 DB/6 WB 25 26 6 Piping requirements 27 Foreword 28 6 Foreword Piping requirements 1. Allowable length/height difference of refrigerant piping D Follower unit 3 Height difference between Outdoor unit outdoor units H3 5m A Header unit B Follower unit 1 Lb Header unit Follower unit 2 Follower unit 1 Follower unit 2 Lc Ld LB Main connecting piping between outdoor units Length corresponded to farthest piping between outdoor units LO 25 m L1 Height difference between outdoor units H1 50m C Follower unit 2 Ex.2 Follower unit 1 Connecting piping of outdoor unit T-shape branching La joint LA Main piping Ex.1 Header unit NOTE : In case of connecting method Ex. 2, a large amount of refrigerant and refrigerant oil may return to the head unit. Therefore, set the T-shape joint so that oil does not enter directly. Connecting piping of indoor unit 1st branching section 6 Branching header Branching piping L2 a L7 b c d e Indoor unit L3 Equivalent length corresponded to farthest piping L 175 m Equivalent length corresponded to farthest piping after 1st branching Li f g Height difference between indoor units H2 30m L6 L5 L4 Y-joint 65 m h i j Indoor unit System restrictions Max. No. of combined outdoor units 4 units Max. capacity of combined outdoor units 48 HP Max. No. of connected indoor units 48 units H2 <15 Max. capacity of combined indoor units H2 >15 135% 105% Note 1) Combination of outdoor units : Header unit (1 unit) + Follower units (0 to 3 units). Header unit is the outdoor unit nearest to the connected indoor units. Note 2) Install the outdoor units in order of capacity. (Header unit Follower unit 1 Follower unit 2 Follower unit 3) Note 3) Refer to outdoor unit combination table. Note 4) Piping to indoor units shall be perpendicular to piping to the header outdoor unit as <Ex.1>. Do not connect piping to indoor units in the same direction of Header outdoor unit as <Ex.2>. Allowable length and height difference of refrigerant piping Allowable value Total extension of pipe (Liquid pipe, real length) Farthest piping length L (*) Piping length 300 m Real length 150 m Equivalent length 175 m Piping section LA + LB + La + Lb + Lc + Ld + L1 + L2 + L3 + L4+ L5 + L6 + L7 + a + b + c + d + e + f + g + h + i + j LA + LB + Ld + L1 + L3 + L4 + L5 + L6 + j Equivalent length of farthest piping from 1st branching Li (*) 65 m L3 + L4 + L5 + L6 + j Equivalent length of farthest piping between outdoor units LO (*) 25 m LA + LB + Ld, (LA + Lb, LA + LB + Lc) Max. equivalent length of main piping (***) Max. equivalent length of outdoor unit connecting piping 85 m L1 10 m Ld, (La, Lb, Lc) 30 m a, b, c, d, e, f, g, h, i, j _ Max. real length of indoor unit connecting piping Height between indoor and outdoor units H1 Upper outdoor unit Lower outdoor unit Height difference Height between indoor units H2 Height between outdoor units H3 50 m 40 m (**) _ 30 m _ 5m _ * (D) is outdoor unit furthest from the 1st branch and ( j ) is the indoor unit furthest from the 1st branch. ** If the height difference (H2) between indoor units exceeds 3m, set below 30m. *** If the maximum combined outdoor unit capacity is 46 HP or more, then the maximum equivalent length is restricted to 70m. 29 2. Selection of refrigerant piping Branching piping Follower unit 3 Follower unit 2 Follower unit 1 Header unit 6 Header branching pipe 4 Indoor unit connecting piping Outdoor unit 5 4 5 5 5 5 5 5 2 Balance pipe Indoor unit 6 T-shape 1 Outdoor unit 1 connecting piping 1 branching joint 1 3 Main piping 2 2 branching joint 4 4 4 5 5 5 4 Main connecting piping between outdoor units 6 6 Y-shape 1st branching Indoor unit section connecting piping Indoor unit 1 Pipe size of outdoor unit (Table 1) Model name 5 Piping of indoor unit (Table 5) Gas side Liquid side MAP0501T8 MAP0501HT8 MAP0501HT7 O / 15.9 O / 9.5 MAP0601T8 MAP0601HT8 MAP0601HT7 O / 19.1 O / 9.5 MAP0801T8 MAP0801HT8 MAP0801HT7 O / 22.2 O / 12.7 MAP1001T8 MAP1001HT8 MAP1001HT7 O / 22.2 MAP1201T8 MAP1201HT8 MAP1201HT7 O / 28.6 MMY- Gas side Liquid side Real length 15m or less O / 9.5 O / 6.4 Real length exceeds 15m O / 12.7 O / 6.4 015 type to 018 type O / 12.7 O / 6.4 O / 12.7 024 type to 056 type O / 15.9 O / 9.5 O / 12.7 072 type to 096 type O / 22.2 O / 12.7 2 Connecting pipe size between outdoor units (Table 2) Total capacity code of outdoor units at downstream side Gas side Liquid side 14 to below 22 O / 28.6 O / 15.9 22 to below 26 O / 34.9 O / 15.9 26 to below 36 O / 34.9 O / 19.1 36 or more O / 41.3 O / 22.2 O / 9.5 Gas side Liquid side Below 6 O / 15.9 O / 9.5 6 to below 8 O / 19.1 O / 9.5 8 to below 12 O / 22.2 O / 12.7 12 to below 14 O / 28.6 O / 12.7 14 to below 22 O / 28.6 O / 15.9 22 to below 26 O / 34.9 O / 15.9 26 to below 36 O / 34.9 O / 19.1 36 to below 46 O / 41.3 O / 22.2 *5 Total capacity code of indoor unit *1 Y-shape branching joint 2 * For 4 branching * Branching header 3 *6 For 8 branching T-shape branching joint (For connecting outdoor unit) 4 Pipe size between branching sections (Table 4) RBM-BY53E 6.4 to below 14.2 RBM-BY103E 14.2 to below 25.2 RBM-BY203E 25.2 or more RBM-BY303E Below 14.2 RBM-HY1043E 14.2 to below 25.2 RBM-HY2043E Below 14.2 RBM-HY1083E 14.2 to below 25.2 RBM-HY2083E 1 set of 3 types of T-shape joint pipes as described below: The required quantity is arranged and combined at the site. Balance pipe (Corresponded difference O/ 9.52) 1 Piping at liquid side (Corresponded difference O/ 9.5 to O/ 22.1) 1 RBM-BT13E Piping at gas side (Corresponded difference O/ 15.9 to O/ 41.3) 1 O / 22.2 Determine thickness of the main pipe according to capacity of the outdoor units. 7 Minimum wall thickness for R410A application (Table 7) Total capacity code of indoor units at downstream side *1 Gas side Liquid side OD (mm) Minimum wall thickness (mm) 2.8 or less O / 12.7 O / 9.5 OK OK 1/4'' 6.35 0.80 2.8 to below 6.4 O / 15.9 O / 9.5 OK OK 3/8'' 9.52 0.80 6.4 to below 12.2 O / 22.2 O / 12.7 OK OK 1/2'' 12.70 0.80 12.2 to below 20.2 O / 28.6 O / 15.9 OK OK 5/8'' 15.88 1.00 20.2 to below 25.2 O / 34.9 O / 15.9 NG*4 OK 3/4'' 19.05 1.00 25.2 to below 35.2 O / 34.9 O / 19.1 NG*4 OK 7/8'' 22.20 1.00 35.2 or more O / 41.3 O / 22.2 NG*4 OK 1.1/8'' 28.58 1.00 NG*4 OK 1.3/8'' 34.92 1.10 NG*4 OK 1.5/8'' 41.28 1.25 If the total capacity code value of indoor units exceeds that of the outdoor units, apply the capacity code of outdoor units. *1 *2 *3 *4 *5 *6 30 Model name Below 6.4 Total capacity code of all outdoor units *1 O / 41.3 6 Selection of branching section (Table 6) Balance pipe 3 Size of main pipe (Table 3) 46 or more Capacity rank 007 type to 012 type Soft Half hard or hard OD (Inch) Code is determined according to the capacity rank. When using a Y-shape branching joint for the 1st branch, select according to capacity code of the outdoor unit. For 1 line after branching header indoor units with a maximum capacity code of 6.0 in total can be connected. If the pipe size is O / 19.0 or more, use a suitable material as detailed in the installation manual. The maximum equivalent length of the main pipe should be 70m. When the first branch is a header with the outdoor total capacity codes of 12 to 26, apply the model RBMHY2043E(4-branch) or RBM-HY2083E(8-branch) regardless of the total capacity codes of the down-stream indoor units. Foreword 3. Charging requirement with additional refrigerant After the system has been vacuumed, replace the vacuum pump with a refrigerant cylinder and charge the system with additional refrigerant. Calculating the amount of additional refrigerant required R410A Refrigerant in the system when shipped from the factory Refrigerant amount charged in factory 5HP 6HP 8HP 10HP 12HP Heat pump model 8.5kg 8.5kg 12.5kg 12.5kg 12.5kg Cooling only model 8.0kg 8.0kg 11.0kg 11.0kg 11.0kg When the system is charged with refrigerant at the factory, the amount of refrigerant needed for the pipes at the site is not included. Therefore, calculate the additional amount needed and add the required amount to the system. (Calculation) 6 Additional refrigerant charge amount is calculated based on the size of liquid pipe at site and its real length. Additional refrigerant charge amount at site = Additional refrigerant charge amount + Real length of liquid pipe X Compensation by system HP (Table 2) per liquid pipe 1m (Table 1) Example : Additional charge amount R (kg) = (L1 x 0.025kg/m) + (L2 x 0.055kg/m) + (L3 x 0.105kg/m) + (3.0kg) L1 : Real total length of liquid pipe 6.4 (m) L2 : Real total length of liquid pipe 9.5 (m) L3 : Real total length of liquid pipe 12.7 (m) Table 7-1 Pipe dia. at liquid side Additional refrigerant amount/1m o/ 6.4 o/ 9.5 o/ 12.7 o/ 15.9 o/ 19.0 o/ 22.2 0.025kg 0.055kg 0.105kg 0.160kg 0.250kg 0.350kg Table 7-2 Combined horse power (HP) Outdoor combination (HP) Compensation by System HP (kg) Combined horse power (HP) Outdoor combination (HP) Compensation by System HP (kg) 5 5 0.0 28 10 10 8 -2.0 6 6 0.0 30 10 10 10 0.0 8 8 1.5 12 10 10 1.0 10 10 2.5 8 8 8 12 12 3.5 12 12 10 14 8 6 0.0 10 8 8 16 8 8 0.0 12 12 12 18 10 8 0.0 10 10 8 8 -6.0 20 10 10 3.0 38 10 10 10 8 -6.0 12 10 5.0 40 10 10 10 10 -5.0 8 8 0.0 42 12 10 10 10 -4.0 12 12 7.0 44 12 12 10 10 -2.0 8 8 8 -4.0 46 12 12 12 10 0.0 10 8 8 -4.0 48 12 12 12 12 2.0 22 24 26 6 32 34 36 8 -6.0 3.0 8 -6.0 4.0 31 32 7 Refrigerant cycle diagram 33 Foreword 34 7 Refrigerant cycleForeword diagram 1. Inverter Unit (5, 6, 8, 10, 12HP) Model: MMY-MAP0501HT, MAP0601HT, MAP0801HT, MAP1001HT, MAP1201HT (8,10,12HP) Propeller fan (PMV1) (PMV2) M Sensor (TE1) Fan motor (Right side) Sensor (TO) Air heat exchanger at outdoor side Strainer (Left side) Pulse motor valve (PMV) Air heat exchanger at outdoor side (5,6HP) 7 (PMV1) Strainer 4-Way valve Solenoid valve (SV5) Check valve Sensor (TS1) Solenoid valve (SV2) Capillary tube High-pressure sensor Check joint Sensor (TL) Low-pressure sensor Check joint Capillary tube Oil Solenoid valve Strainer separator (SV3D) Capillary tube Strainer Check valve Solenoid valve (SV41) Check valve High-pressure switch High-pressure switch Check joint Capillary tube Compressor 1 (Inverter) Sensor (TD1) Solenoid valve (SV3C) Sensor (TK3) Strainer Check valve Capillary tube Sensor (TK1) Solenoid valve (SV3E) Strainer Check valve Oil tank Sensor (TK4) Capillary tube Strainer Strainer Accumulator Sensor (TD2) Capillary tube Sensor (TK2) Capillary tube Strainer Solenoid valve (SV42) Compressor 2 (Inverter) Liquid tank Check valve Solenoid valve (SV3A) Solenoid valve (SV3B) Check valve Balance Liquid pipe side servise servise valve valve Gas side servise valve 35 2. Explanation of Functional Parts Functional part name Solenoid valve 1.SV3A 2.SV3B (Connector CN313: Blue) 1) Returns oil in the balance pipe to the compressor. 3.SV3C (Connector CN314: Black) 1) Pressurizes oil reserved in the oil tank during operation. 4.SV3D (Connector CN323: White) 1) Reserves oil in the oil separator during OFF time, and supplies oil during operation. 5.SV3E (Connector CN323: White) 1) Turns on during operation and balances oil between the compressors. 6.SV2 (Hot gas bypass) (Connector CN312: White) 1) Low pressure release function 2) High pressure release function 3) Gas balance during off status 7.SV4(n) (Start compensation valve of compressor) (Connector CN311: Blue) 1) For gas balance start 2) High pressure release function 3) Low pressure release function 8.SV5 (Connector CN310: White) (for Heating model only) 1) Preventive function for high-pressure rising in heating operation 7 4-way valve (Connector CN317: Blue) 1) Cooling/heating exchange 2) Reverse defrost Pulse motor valve PMV1,2 (Connector CN300, 301: White) 1) Super heat control function in heating operation 2) Liquid line shut-down function while follower unit stops 3) Under-cool adjustment function in cooling operation Oil separator Temp. sensor 1) Prevention for rapid decreasing of oil (Decreases oil flowing to the cycle) 2) Reserve function of surplus oil 1. TD1 TD2 (TD1: Connector, CN502: White, TD2: Connector, CN503: Pink) 1) Protection of compressor discharge temp. Used for release 2. TS1 (Connector CN504: White) 1) Controls super heat in heating operation 3. TE1 (Connector CN505: Green) 1) Controls defrost in heating operation 2) Controls outdoor fan in heating operation 4. TK1, TK2, TK3, TK4 Pressure sensor Heater Balance pipe 36 Functional outline (Connector CN324: Red) 1) Collects oil in the oil tank during OFF time. 2) Supplies oil in the oil tank during ON time. Connector CN514: Black, TK2 Connector CN515: Green, ( TK1 TK3 Connector CN516: Red, TK4 Connector CN523: Yellow ) 1) Judges oil level of the compressor 5. TL (Connector CN521: White) 1) Detects under cool in cooling operation 6. TO (Connector CN507: Yellow) 1) Detects outside temperature 1.High pressure sensor (Connector CN501: Red) 1) Detects high pressure and controls compressor capacity 2) Detects high pressure in cooling operation, and controls the fan in low ambient cooling operation 2. Low pressure sensor (Connector CN500: White) 1) Detects low pressure in cooling operation and controls compressor capacity 2) Detects low pressure in heating operation, and controls the super heat Compressor case heater (Compressor 1 Connector CN316: White, Compressor 2 Connector CN315: Blue) 1) Prevents liquid accumulation to compressor Accumulator case heater (Connector CN321: Red) 1) Prevents liquid accumulation to accumulator 1) Oil balancing in each outdoor unit Foreword 3. Indoor Unit Liquid side Gas side Strainer Capillary tube Air heat exchanger at indoor side 7 Pulse Motor Valve (PMV) Strainer Sensor (TCJ) Sensor (TC2) Fan Sensor (TC1) Sensor (TA) M Fan motor (NOTE) MMU-AP0071YH to AP0121YH type air conditioners do not have a TC2 sensor. Functional part name Pulse Motor Valve PMV Temp. sensor Functional outline (Connector CN082 (6P): Blue) 1)Controls super heat in cooling operation 2)Controls under cool in heating operation 3)Recovers refrigerant oil in cooling operation 4)Recovers refrigerant oil in heating operation 1. TA (Connector CN104 (2P): Yellow) 1)Detects indoor suction temperature 2. TC1 (Connector CN100 (3P): Brown) 1)Controls PMV super heat in cooling operation 3. TC2 (Connector CN101 (2P): Black) 1)Controls PMV under cool in heating operation 4. TCJ (Connector CN102 (2P): Red) 1)Controls PMV super heat in cooling operation 2) MMU-AP0071 to AP0121YH only Controls PMV under cool in heating operation 37 COMBINED REFRIGERANT PIPES SYSTEMATIC DRAWING 1. Normal Operation (COOL Mode / DEFROST Mode) Header unit (MMY-MAP1001H) Follower unit (MMY-MAP1001H) FM FM TE1 TE1 TO PMV1 PMV2 TO 4-Way valve SV5 PMV1 PMV2 4-Way valve SV5 TS1 TL TS1 SV2 Pd sensor SV2 Pd sensor TL Ps sensor Ps sensor OS OS SV3D Liquid tank SV41 SV42 HP HP SV3C TK1 SV3E HP TK2 TK3 TK1 Oil tank TK4 SV3C TD1 Compressor 1 TK3 SV42 HP Accumulator TD2 Compressor 2 Compressor 1 TD1 SV41 SV3E SV3A Accumulator TD2 Compressor 2 7 SV3D Liquid tank TK2 Oil tank TK4 SV3A SV3B SV3B Balance pipe Liquid pipe Gas pipe Gas pipe Liquid pipe Strainer Strainer Strainer PMV TC2 TCJ Strainer Strainer PMV TC1 TC2 TCJ Strainer Strainer PMV TC1 TC2 TCJ Strainer PMV TC1 TC2 TCJ TC1 Indoor unit High-pressure gas or condensate liquid refrigerant Evaporative gas refrigerant (Low-pressure gas) NOTE An outdoor unit which is connected with indoor/outdoor communication lines is referred to as the ‘‘Header unit’’, and the other unit is called the ‘‘Follower unit’’. 38 (Example: 20HP system) 2. Normal Operation (HEAT Mode) Header unit (MMY-MAP1001H) Follower unit (MMY-MAP1001H) FM FM TE1 TE1 TO PMV1 PMV2 TO 4-Way valve SV5 PMV1 PMV2 4-Way valve SV5 TS1 TL TS1 SV2 Pd sensor SV2 Pd sensor TL Ps sensor Ps sensor OS OS SV3D SV3D Liquid tank Liquid tank SV42 HP HP SV3C TK1 SV3E HP TK2 TK3 TK1 Oil tank TK4 SV3C TD1 Compressor 1 TK3 SV3E SV3A 7 SV42 HP Accumulator TD2 Compressor 2 Compressor 1 TD1 SV41 Accumulator TD2 Compressor 2 SV41 TK2 Oil tank TK4 SV3A SV3B SV3B Balance pipe Liquid pipe Gas pipe Gas pipe Liquid pipe Strainer Strainer Strainer PMV TC2 TCJ Strainer Strainer PMV TC1 TC2 TCJ Strainer Strainer PMV TC1 TC2 TCJ Strainer PMV TC1 TC2 TCJ TC1 Indoor unit High-pressure gas or condensate liquid refrigerant Evaporative gas refrigerant (Low-pressure gas) NOTE An outdoor unit which is connected with indoor/outdoor communication lines is referred to as the ‘‘Header unit’’, and the other unit is called the ‘‘Follower unit’’. (Example: 20HP system) 39 3. Backup Operation (Cooling Operation when Header Outdoor unit failure) Header unit (MMY-MAP1001H) Follower unit (MMY-MAP1001H) Unit set temporarily to header unit during emergent operation. Failure FM FM TE1 TE1 TO TO *1 PMV1 PMV2 4-Way valve SV5 PMV1 PMV2 4-Way valve SV5 TS1 TL TS1 SV2 Pd sensor SV2 Pd sensor TL Ps sensor Ps sensor OS OS SV3D Liquid tank SV41 SV42 HP HP SV3C TK1 SV3E HP TK2 TK3 TK1 Oil tank TK4 SV3C TD1 Compressor 1 TK3 SV42 HP Accumulator TD2 Compressor 2 Compressor 1 TD1 SV41 SV3E SV3A TK2 Oil tank TK4 SV3A SV3B *3 *2 Accumulator TD2 Compressor 2 7 SV3D Liquid tank SV3B Balance pipe *1 When liquid leaks from PMV, packed valve Liquid pipe at liquid side = Close fully Gas pipe *2 Gas pipe service valve = Close fully *3 Balance pipe packed valve = Open fully Gas pipe Liquid pipe Strainer Strainer Strainer PMV TC2 TCJ Strainer Strainer PMV TC1 TC2 TCJ Strainer Strainer PMV TC1 TC2 TCJ Strainer PMV TC1 TC2 TCJ TC1 Indoor unit High-pressure gas or condensate liquid refrigerant Evaporative gas refrigerant (Low-pressure gas) NOTE An outdoor unit which is connected with indoor/outdoor communication lines is referred to as the ‘‘Header unit’’, and the other unit is called the ‘‘Follower unit’’. 40 (Example: 20HP system) 4. Emergent Operation (Heating Operation when Header Outdoor unit failure) Header unit (MMY-MAP1001H) Failure Follower unit (MMY-MAP1001H) Unit set temporarily to header unit during emergent operation. FM FM TE1 TE1 TO TO *1 PMV1 PMV2 4-Way valve SV5 PMV1 PMV2 4-Way valve SV5 TS1 TS1 SV2 Pd sensor TL SV2 Pd sensor TL Ps sensor Ps sensor OS OS SV3D SV3D Liquid tank Liquid tank SV42 HP HP SV3C TK1 SV3E HP TK2 TK3 TK1 Oil tank TK4 SV3C TD1 Compressor 1 TK3 SV3E SV3A *2 Accumulator TD2 TK2 Oil tank TK4 SV3A SV3B *3 7 SV42 HP Accumulator TD2 Compressor 2 Compressor 1 TD1 SV41 Compressor 2 SV41 SV3B Balance pipe *1 When liquid leaks from PMV, packed valve Liquid pipe at liquid side = Close fully Gas pipe *2 Gas pipe service valve = Close fully *3 Balance pipe packed valve = Open fully Gas pipe Liquid pipe Strainer Strainer Strainer PMV TC2 TCJ Strainer Strainer PMV TC1 TC2 TCJ Strainer Strainer PMV TC1 TC2 TCJ Strainer PMV TC1 TC2 TCJ TC1 Indoor unit High-pressure gas or condensate liquid refrigerant Evaporative gas refrigerant (Low-pressure gas) NOTE An outdoor unit which is connected with indoor/outdoor communication lines is referred to as the ‘‘Header unit’’, and the other unit is called the ‘‘Follower unit’’. (Example: 20HP system) 41 5. Recovery of Refrigerant in Failed Outdoor Unit (In Case of Failure of Follower Unit) Header unit (MMY-MAP1001H) Follower unit (MMY-MAP1001H) Failure FM FM TE1 TE1 TO PMV1 PMV2 TO 4-Way valve SV5 PMV1 PMV2 4-Way valve SV5 TS1 TS1 SV2 Pd sensor TL SV2 Pd sensor TL Ps sensor Ps sensor OS OS SV3D SV3D Liquid tank SV42 HP HP SV3C TK3 TK1 SV3E SV42 HP Accumulator TD2 HP TK2 TK3 TK1 Oil tank TK4 SV3C TD1 Compressor 2 Compressor 1 TD1 SV41 SV3E SV3A Accumulator TD2 Compressor 2 SV41 Compressor 1 7 Liquid tank TK2 Oil tank TK4 SV3A SV3B SV3B *1 Balance pipe *2 Liquid pipe *3 Gas pipe *1 Packed valve of balance pipe = Open fully *2 Packed valve at liquid side = Close fully *3 Service valve open fully at gas side Close fully 10 minutes after operation start Gas pipe Liquid pipe Strainer Strainer Strainer PMV TC2 TCJ Strainer Strainer PMV TC1 TC2 TCJ Strainer Strainer PMV TC1 TC2 TCJ Strainer PMV TC1 TC2 TCJ TC1 Indoor unit High-pressure gas or condensate liquid refrigerant Evaporative gas refrigerant (Low-pressure gas) NOTE An outdoor unit which is connected with indoor/outdoor communication lines is referred to as ‘‘Header unit’’, and the other unit is called the ‘‘Follower unit’’. 42 (Example: 20HP system) 8 Sensible capacity table 43 Foreword 44 8 Foreword Sensible capacity table 4-way Discharge Cassette Type ( MMU-AP****H) unit size 009 012 015 018 outdoor air temp. o CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 o 14.0 CWB o 20 CDB TC SHC 2.3 1.9 2.3 1.9 2.3 1.9 2.3 1.9 2.3 1.9 2.3 1.9 2.3 1.9 2.3 1.9 2.3 1.9 2.3 1.9 2.3 1.9 2.3 1.9 2.3 1.9 2.3 1.9 2.2 1.8 2.2 1.8 3.0 2.3 3.0 2.3 3.0 2.3 3.0 2.3 3.0 2.3 3.0 2.3 3.0 2.3 2.3 3.0 3.0 2.3 3.0 2.3 3.0 2.3 3.0 2.3 3.0 2.3 3.0 2.3 2.9 2.2 2.8 2.2 3.7 2.8 3.7 2.8 3.7 2.8 3.7 2.8 3.7 2.8 3.7 2.8 3.7 2.8 3.7 2.8 3.7 2.8 3.7 2.8 3.7 2.8 3.7 2.8 3.7 2.8 3.7 2.8 3.6 2.7 3.5 2.7 4.6 3.5 4.6 3.5 4.6 3.5 4.6 3.5 4.6 3.5 4.6 3.5 4.6 3.5 4.6 3.5 4.6 3.5 4.6 3.5 4.6 3.5 4.6 3.5 4.6 3.5 4.6 3.5 4.5 3.4 4.3 3.3 o 16.0 CWB o 23 CDB TC SHC 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 1.9 2.4 1.9 3.3 2.5 3.3 2.5 3.3 2.5 3.3 2.5 3.3 2.5 3.3 2.5 3.3 2.5 3.3 2.5 3.3 2.5 3.3 2.5 3.3 2.5 3.3 2.5 3.3 2.5 3.3 2.5 3.2 2.4 3.1 2.3 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.0 2.9 3.8 2.8 5.1 3.8 5.1 3.8 5.1 3.8 5.1 3.8 5.1 3.8 5.1 3.8 5.1 3.8 5.1 3.8 5.1 3.8 5.1 3.8 5.1 3.8 5.1 3.8 5.1 3.8 5.1 3.8 4.9 3.7 4.8 3.6 TC : Total capacity [kW] indoor air temp. o o o 18.0 CWB 19.0 CWB 20.0 CWB o o o 26 CDB 27 CDB 28 CDB TC SHC TC SHC TC SHC 2.7 2.1 2.8 2.1 2.9 2.1 2.7 2.1 2.8 2.1 2.9 2.1 2.7 2.1 2.8 2.1 2.9 2.1 2.7 2.1 2.8 2.1 2.9 2.1 2.7 2.1 2.8 2.1 2.9 2.1 2.7 2.1 2.8 2.1 2.9 2.1 2.7 2.1 2.8 2.1 2.9 2.1 2.7 2.1 2.8 2.1 2.9 2.1 2.7 2.1 2.8 2.1 2.9 2.1 2.7 2.1 2.8 2.1 2.9 2.1 2.7 2.1 2.8 2.1 2.9 2.1 2.7 2.1 2.8 2.1 2.9 2.1 2.7 2.1 2.8 2.1 2.9 2.1 2.7 2.1 2.8 2.1 2.9 2.1 2.6 2.0 2.7 2.0 2.8 2.0 2.6 2.0 2.6 2.0 2.7 2.0 3.5 2.6 3.6 2.6 3.7 2.6 3.5 2.6 3.6 2.6 3.7 2.6 3.5 2.6 3.6 2.6 3.7 2.6 3.5 2.6 3.6 2.6 3.7 2.6 3.5 2.6 3.6 2.6 3.7 2.6 3.5 2.6 3.6 2.6 3.7 2.6 3.5 2.6 3.6 2.6 3.7 2.6 3.5 2.6 3.6 2.6 3.7 2.6 3.5 2.6 3.6 2.6 3.7 2.6 3.5 2.6 3.6 2.6 3.7 2.6 3.5 2.6 3.6 2.6 3.7 2.6 3.5 2.6 3.6 2.6 3.7 2.6 3.5 2.6 3.6 2.6 3.7 2.6 3.5 2.6 3.6 2.6 3.7 2.6 3.4 2.5 3.5 2.5 3.6 2.5 3.3 2.5 3.4 2.4 3.5 2.4 4.4 3.2 4.5 3.2 4.6 3.2 4.4 3.2 4.5 3.2 4.6 3.2 4.4 3.2 4.5 3.2 4.6 3.2 4.4 3.2 4.5 3.2 4.6 3.2 4.4 3.2 4.5 3.2 4.6 3.2 4.4 3.2 4.5 3.2 4.6 3.2 4.4 3.2 4.5 3.2 4.6 3.2 4.4 3.2 4.5 3.2 4.6 3.2 4.4 3.2 4.5 3.2 4.6 3.2 4.4 3.2 4.5 3.2 4.6 3.2 4.4 3.2 4.5 3.2 4.6 3.2 4.4 3.2 4.5 3.2 4.6 3.2 4.4 3.2 4.5 3.2 4.6 3.2 4.4 3.2 4.5 3.2 4.6 3.2 4.2 3.1 4.4 3.1 4.5 3.1 4.1 3.0 4.2 3.0 4.4 3.0 5.4 4.0 5.6 4.0 5.8 4.0 5.4 4.0 5.6 4.0 5.8 4.0 5.4 4.0 5.6 4.0 5.8 4.0 5.4 4.0 5.6 4.0 5.8 4.0 5.4 4.0 5.6 4.0 5.8 4.0 5.4 4.0 5.6 4.0 5.8 4.0 5.4 4.0 5.6 4.0 5.8 4.0 5.4 4.0 5.6 4.0 5.8 4.0 5.4 4.0 5.6 4.0 5.8 4.0 5.4 4.0 5.6 4.0 5.8 4.0 5.4 4.0 5.6 4.0 5.8 4.0 5.4 4.0 5.6 4.0 5.8 4.0 5.4 4.0 5.6 4.0 5.8 4.0 5.4 4.0 5.6 4.0 5.8 4.0 5.3 3.9 5.4 3.9 5.6 3.9 5.1 3.8 5.3 3.8 5.4 3.8 SHC : Sensible capacity [kW] o 22.0 CWB o 30 CDB TC SHC 3.1 2.1 3.1 2.1 3.1 2.1 3.1 2.1 3.1 2.1 3.1 2.1 3.1 2.1 3.1 2.1 3.1 2.1 3.1 2.1 3.1 2.1 3.1 2.1 3.1 2.1 3.1 2.1 3.0 2.0 2.9 2.0 3.9 2.6 3.9 2.6 3.9 2.6 3.9 2.6 3.9 2.6 3.9 2.6 3.9 2.6 3.9 2.6 3.9 2.6 3.9 2.6 3.9 2.6 3.9 2.6 3.9 2.6 3.9 2.6 3.8 2.5 3.7 2.4 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.7 3.1 4.6 3.0 6.1 4.0 6.1 4.0 6.1 4.0 6.1 4.0 6.1 4.0 6.1 4.0 6.1 4.0 6.1 4.0 6.1 4.0 6.1 4.0 6.1 4.0 6.1 4.0 6.1 4.0 6.1 4.0 5.9 3.8 5.7 3.7 o 24.0 CWB o 32 CDB TC SHC 3.2 2.0 3.2 2.0 3.2 2.0 3.2 2.0 3.2 2.0 3.2 2.0 3.2 2.0 3.2 2.0 3.2 2.0 3.2 2.0 3.2 2.0 3.2 2.0 3.2 2.0 3.2 2.0 3.1 2.0 3.0 1.9 4.1 2.5 4.1 2.5 4.1 2.5 4.1 2.5 4.1 2.5 4.1 2.5 4.1 2.5 4.1 2.5 4.1 2.5 4.1 2.5 4.1 2.5 4.1 2.5 4.1 2.5 4.1 2.5 4.0 2.4 3.9 2.4 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.0 3.0 4.8 2.9 6.4 3.9 6.4 3.9 6.4 3.9 6.4 3.9 6.4 3.9 6.4 3.9 6.4 3.9 6.4 3.9 6.4 3.9 6.4 3.9 6.4 3.9 6.4 3.9 6.4 3.9 6.4 3.9 6.2 3.7 6.0 3.6 8 45 4-way Discharge Cassette Type ( MMU-AP****H) unit size 024 8 027 030 036 46 outdoor air temp. o CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 o 14.0 CWB o 20 CDB TC SHC 5.8 4.3 5.8 4.3 5.8 4.3 5.8 4.3 5.8 4.3 5.8 4.3 5.8 4.3 5.8 4.3 5.8 4.3 5.8 4.3 5.8 4.3 5.8 4.3 5.8 4.3 5.8 4.3 5.6 4.2 5.5 4.1 6.6 4.9 6.6 4.9 6.6 4.9 6.6 4.9 6.6 4.9 6.6 4.9 6.6 4.9 6.6 4.9 6.6 4.9 6.6 4.9 6.6 4.9 6.6 4.9 6.6 4.9 6.6 4.9 6.4 4.7 6.2 4.6 7.4 5.5 7.4 5.5 7.4 5.5 7.4 5.5 7.4 5.5 7.4 5.5 7.4 5.5 7.4 5.5 7.4 5.5 7.4 5.5 7.4 5.5 7.4 5.5 7.4 5.5 7.4 5.5 7.2 5.3 7.0 5.2 9.2 6.8 9.2 6.8 9.2 6.8 9.2 6.8 9.2 6.8 9.2 6.8 9.2 6.8 9.2 6.8 9.2 6.8 9.2 6.8 9.2 6.8 9.2 6.8 9.2 6.8 9.2 6.8 8.9 6.6 8.7 6.4 o 16.0 CWB o 23 CDB TC SHC 6.4 4.6 6.4 4.6 6.4 4.6 6.4 4.6 6.4 4.6 6.4 4.6 6.4 4.6 6.4 4.6 6.4 4.6 6.4 4.6 6.4 4.6 6.4 4.6 6.4 4.6 6.4 4.6 6.2 4.5 6.1 4.4 7.3 5.2 7.3 5.2 7.3 5.2 7.3 5.2 7.3 5.2 7.3 5.2 7.3 5.2 7.3 5.2 7.3 5.2 7.3 5.2 7.3 5.2 7.3 5.2 7.3 5.2 7.3 5.2 7.0 5.0 6.8 4.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 7.9 5.7 7.7 5.5 10.2 7.3 10.2 7.3 10.2 7.3 10.2 7.3 10.2 7.3 10.2 7.3 10.2 7.3 10.2 7.3 10.2 7.3 10.2 7.3 10.2 7.3 10.2 7.3 10.2 7.3 10.2 7.3 9.8 7.0 9.6 6.8 TC : Total capacity [kW] indoor air temp. o o o 18.0 CWB 19.0 CWB 20.0 CWB o o o 26 CDB 27 CDB 28 CDB TC SHC TC SHC TC SHC 6.9 4.9 7.1 4.9 7.3 4.9 6.9 4.9 7.1 4.9 7.3 4.9 6.9 4.9 7.1 4.9 7.3 4.9 6.9 4.9 7.1 4.9 7.3 4.9 6.9 4.9 7.1 4.9 7.3 4.9 6.9 4.9 7.1 4.9 7.3 4.9 6.9 4.9 7.1 4.9 7.3 4.9 6.9 4.9 7.1 4.9 7.3 4.9 6.9 4.9 7.1 4.9 7.3 4.9 6.9 4.9 7.1 4.9 7.3 4.9 6.9 4.9 7.1 4.9 7.3 4.9 6.9 4.9 7.1 4.9 7.3 4.9 6.9 4.9 7.1 4.9 7.3 4.9 6.9 4.9 7.1 4.9 7.3 4.9 6.7 4.8 6.9 4.7 7.1 4.7 6.5 4.6 6.7 4.6 6.9 4.6 7.8 5.5 8.0 5.5 8.2 5.5 7.8 5.5 8.0 5.5 8.2 5.5 7.8 5.5 8.0 5.5 8.2 5.5 7.8 5.5 8.0 5.5 8.2 5.5 7.8 5.5 8.0 5.5 8.2 5.5 7.8 5.5 8.0 5.5 8.2 5.5 7.8 5.5 8.0 5.5 8.2 5.5 7.8 5.5 8.0 5.5 8.2 5.5 7.8 5.5 8.0 5.5 8.2 5.5 7.8 5.5 8.0 5.5 8.2 5.5 7.8 5.5 8.0 5.5 8.2 5.5 7.8 5.5 8.0 5.5 8.2 5.5 7.8 5.5 8.0 5.5 8.2 5.5 7.8 5.5 8.0 5.5 8.2 5.5 7.5 5.3 7.7 5.3 8.0 5.3 7.3 5.2 7.5 5.2 7.8 5.2 8.7 6.2 9.0 6.2 9.3 6.2 8.7 6.2 9.0 6.2 9.3 6.2 8.7 6.2 9.0 6.2 9.3 6.2 8.7 6.2 9.0 6.2 9.3 6.2 8.7 6.2 9.0 6.2 9.3 6.2 8.7 6.2 9.0 6.2 9.3 6.2 8.7 6.2 9.0 6.2 9.3 6.2 8.7 6.2 9.0 6.2 9.3 6.2 8.7 6.2 9.0 6.2 9.3 6.2 8.7 6.2 9.0 6.2 9.3 6.2 8.7 6.2 9.0 6.2 9.3 6.2 8.7 6.2 9.0 6.2 9.3 6.2 8.7 6.2 9.0 6.2 9.3 6.2 8.7 6.2 9.0 6.2 9.3 6.2 8.5 6.0 8.7 6.0 9.0 6.0 8.2 5.9 8.5 5.8 8.7 5.8 10.9 7.7 11.2 7.7 11.5 7.7 10.9 7.7 11.2 7.7 11.5 7.7 10.9 7.7 11.2 7.7 11.5 7.7 10.9 7.7 11.2 7.7 11.5 7.7 10.9 7.7 11.2 7.7 11.5 7.7 10.9 7.7 11.2 7.7 11.5 7.7 10.9 7.7 11.2 7.7 11.5 7.7 10.9 7.7 11.2 7.7 11.5 7.7 10.9 7.7 11.2 7.7 11.5 7.7 10.9 7.7 11.2 7.7 11.5 7.7 10.9 7.7 11.2 7.7 11.5 7.7 10.9 7.7 11.2 7.7 11.5 7.7 10.9 7.7 11.2 7.7 11.5 7.7 10.9 7.7 11.2 7.7 11.5 7.7 10.5 7.5 10.8 7.5 11.2 7.5 10.2 7.3 10.5 7.2 10.9 7.2 SHC : Sensible capacity [kW] o 22.0 CWB o 30 CDB TC SHC 7.7 4.9 7.7 4.9 7.7 4.9 7.7 4.9 7.7 4.9 7.7 4.9 7.7 4.9 7.7 4.9 7.7 4.9 7.7 4.9 7.7 4.9 7.7 4.9 7.7 4.9 7.7 4.9 7.5 4.7 7.3 4.6 8.7 5.4 8.7 5.4 8.7 5.4 8.7 5.4 8.7 5.4 8.7 5.4 8.7 5.4 8.7 5.4 8.7 5.4 8.7 5.4 8.7 5.4 8.7 5.4 8.7 5.4 8.7 5.4 8.4 5.3 8.2 5.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.5 5.9 9.2 5.8 12.2 7.6 12.2 7.6 12.2 7.6 12.2 7.6 12.2 7.6 12.2 7.6 12.2 7.6 12.2 7.6 12.2 7.6 12.2 7.6 12.2 7.6 12.2 7.6 12.2 7.6 12.2 7.6 11.8 7.4 11.5 7.2 o 24.0 CWB o 32 CDB TC SHC 8.1 4.7 8.1 4.7 8.1 4.7 8.1 4.7 8.1 4.7 8.1 4.7 8.1 4.7 8.1 4.7 8.1 4.7 8.1 4.7 8.1 4.7 8.1 4.7 8.1 4.7 8.1 4.7 7.8 4.6 7.6 4.5 9.1 5.3 9.1 5.3 9.1 5.3 9.1 5.3 9.1 5.3 9.1 5.3 9.1 5.3 9.1 5.3 9.1 5.3 9.1 5.3 9.1 5.3 9.1 5.3 9.1 5.3 9.1 5.3 8.8 5.2 8.6 5.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 9.9 5.8 9.7 5.6 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.4 7.2 12.0 7.0 Foreword 4-way Discharge Cassette Type ( MMU-AP****H) unit size 048 056 outdoor air temp. o CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 o 14.0 CWB o 20 CDB TC SHC 11.5 8.7 11.5 8.7 11.5 8.7 11.5 8.7 11.5 8.7 11.5 8.7 11.5 8.7 11.5 8.7 11.5 8.7 11.5 8.7 11.5 8.7 11.5 8.7 11.5 8.7 11.5 8.7 11.1 8.4 10.8 8.2 13.1 9.8 13.1 9.8 13.1 9.8 13.1 9.8 13.1 9.8 13.1 9.8 13.1 9.8 13.1 9.8 13.1 9.8 13.1 9.8 13.1 9.8 13.1 9.8 13.1 9.8 13.1 9.8 12.7 9.4 12.4 9.2 o 16.0 CWB o 23 CDB TC SHC 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.3 9.0 12.0 8.7 14.5 10.4 14.5 10.4 14.5 10.4 14.5 10.4 14.5 10.4 14.5 10.4 14.5 10.4 14.5 10.4 14.5 10.4 14.5 10.4 14.5 10.4 14.5 10.4 14.5 10.4 14.5 10.4 14.1 10.1 13.7 9.8 TC : Total capacity [kW] indoor air temp. o o o 18.0 CWB 19.0 CWB 20.0 CWB o o o 26 CDB 27 CDB 28 CDB TC SHC TC SHC TC SHC 13.6 9.8 14.0 9.8 14.4 9.8 13.6 9.8 14.0 9.8 14.4 9.8 13.6 9.8 14.0 9.8 14.4 9.8 13.6 9.8 14.0 9.8 14.4 9.8 13.6 9.8 14.0 9.8 14.4 9.8 13.6 9.8 14.0 9.8 14.4 9.8 13.6 9.8 14.0 9.8 14.4 9.8 13.6 9.8 14.0 9.8 14.4 9.8 13.6 9.8 14.0 9.8 14.4 9.8 13.6 9.8 14.0 9.8 14.4 9.8 13.6 9.8 14.0 9.8 14.4 9.8 13.6 9.8 14.0 9.8 14.4 9.8 13.6 9.8 14.0 9.8 14.4 9.8 13.6 9.8 14.0 9.8 14.4 9.8 13.1 9.5 13.6 9.5 14.0 9.5 12.8 9.2 13.2 9.2 13.6 9.2 15.5 11.0 16.0 11.0 16.5 11.0 15.5 11.0 16.0 11.0 16.5 11.0 15.5 11.0 16.0 11.0 16.5 11.0 15.5 11.0 16.0 11.0 16.5 11.0 15.5 11.0 16.0 11.0 16.5 11.0 15.5 11.0 16.0 11.0 16.5 11.0 15.5 11.0 16.0 11.0 16.5 11.0 15.5 11.0 16.0 11.0 16.5 11.0 15.5 11.0 16.0 11.0 16.5 11.0 15.5 11.0 16.0 11.0 16.5 11.0 15.5 11.0 16.0 11.0 16.5 11.0 15.5 11.0 16.0 11.0 16.5 11.0 15.5 11.0 16.0 11.0 16.5 11.0 15.5 11.0 16.0 11.0 16.5 11.0 15.0 10.7 15.5 10.6 16.0 10.6 14.6 10.4 15.1 10.4 15.5 10.4 SHC : Sensible capacity [kW] o 22.0 CWB o 30 CDB TC SHC 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 14.8 9.4 14.4 9.1 17.4 10.9 17.4 10.9 17.4 10.9 17.4 10.9 17.4 10.9 17.4 10.9 17.4 10.9 17.4 10.9 17.4 10.9 17.4 10.9 17.4 10.9 17.4 10.9 17.4 10.9 17.4 10.9 16.9 10.5 16.4 10.3 o 24.0 CWB o 32 CDB TC SHC 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 15.4 9.2 15.0 8.9 18.2 10.6 18.2 10.6 18.2 10.6 18.2 10.6 18.2 10.6 18.2 10.6 18.2 10.6 18.2 10.6 18.2 10.6 18.2 10.6 18.2 10.6 18.2 10.6 18.2 10.6 18.2 10.6 17.7 10.3 17.2 10.0 8 47 2-way Air Discharge Cassette Type ( MMU-AP****WH) TC : Total capacity [kW] unit size 007 8 009 012 015 48 outdoor air temp. o CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 o 14.0 CWB o 20 CDB TC SHC 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.7 1.5 1.7 1.4 2.3 1.8 2.3 1.8 2.3 1.8 2.3 1.8 2.3 1.8 2.3 1.8 2.3 1.8 2.3 1.8 2.3 1.8 2.3 1.8 2.3 1.8 2.3 1.8 2.3 1.8 2.3 1.8 2.2 1.7 2.2 1.7 3.0 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 2.0 2.9 2.0 2.8 1.9 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.6 2.6 3.5 2.5 o 16.0 CWB o 23 CDB TC SHC 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 1.9 1.6 1.9 1.5 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.8 2.4 1.8 3.3 2.2 3.3 2.2 3.3 2.2 3.3 2.2 3.3 2.2 3.3 2.2 3.3 2.2 3.3 2.2 3.3 2.2 3.3 2.2 3.3 2.2 3.3 2.2 3.3 2.2 3.3 2.2 3.2 2.1 3.1 2.0 4.1 2.9 4.1 2.9 4.1 2.9 4.1 2.9 4.1 2.9 4.1 2.9 4.1 2.9 4.1 2.9 4.1 2.9 4.1 2.9 4.1 2.9 4.1 2.9 4.1 2.9 4.1 2.9 4.0 2.8 3.8 2.7 indoor air temp. o o 18.0 CWB 19.0 CWB o o 26 CDB 27 CDB TC SHC TC SHC 2.1 1.7 2.2 1.7 2.1 1.7 2.2 1.7 2.1 1.7 2.2 1.7 2.1 1.7 2.2 1.7 2.1 1.7 2.2 1.7 2.1 1.7 2.2 1.7 2.1 1.7 2.2 1.7 2.1 1.7 2.2 1.7 2.1 1.7 2.2 1.7 2.1 1.7 2.2 1.7 2.1 1.7 2.2 1.7 2.1 1.7 2.2 1.7 2.1 1.7 2.2 1.7 2.1 1.7 2.2 1.7 2.1 1.7 2.1 1.6 2.0 1.6 2.1 1.6 2.7 2.0 2.8 2.0 2.7 2.0 2.8 2.0 2.7 2.0 2.8 2.0 2.7 2.0 2.8 2.0 2.7 2.0 2.8 2.0 2.7 2.0 2.8 2.0 2.7 2.0 2.8 2.0 2.7 2.0 2.8 2.0 2.7 2.0 2.8 2.0 2.7 2.0 2.8 2.0 2.7 2.0 2.8 2.0 2.7 2.0 2.8 2.0 2.7 2.0 2.8 2.0 2.7 2.0 2.8 2.0 2.6 1.9 2.7 1.9 2.6 1.9 2.6 1.9 3.5 2.3 3.6 2.3 3.5 2.3 3.6 2.3 3.5 2.3 3.6 2.3 3.5 2.3 3.6 2.3 3.5 2.3 3.6 2.3 3.5 2.3 3.6 2.3 3.5 2.3 3.6 2.3 3.5 2.3 3.6 2.3 3.5 2.3 3.6 2.3 3.5 2.3 3.6 2.3 3.5 2.3 3.6 2.3 3.5 2.3 3.6 2.3 3.5 2.3 3.6 2.3 3.5 2.3 3.6 2.3 3.4 2.2 3.5 2.2 3.3 2.2 3.4 2.2 4.4 3.1 4.5 3.1 4.4 3.1 4.5 3.1 4.4 3.1 4.5 3.1 4.4 3.1 4.5 3.1 4.4 3.1 4.5 3.1 4.4 3.1 4.5 3.1 4.4 3.1 4.5 3.1 4.4 3.1 4.5 3.1 4.4 3.1 4.5 3.1 4.4 3.1 4.5 3.1 4.4 3.1 4.5 3.1 4.4 3.1 4.5 3.1 4.4 3.1 4.5 3.1 4.4 3.1 4.5 3.1 4.2 3.0 4.4 3.0 4.1 2.9 4.2 2.9 o 20.0 CWB o 28 CDB TC SHC 2.3 1.7 2.3 1.7 2.3 1.7 2.3 1.7 2.3 1.7 2.3 1.7 2.3 1.7 2.3 1.7 2.3 1.7 2.3 1.7 2.3 1.7 2.3 1.7 2.3 1.7 2.3 1.7 2.2 1.6 2.1 1.6 2.9 2.0 2.9 2.0 2.9 2.0 2.9 2.0 2.9 2.0 2.9 2.0 2.9 2.0 2.9 2.0 2.9 2.0 2.9 2.0 2.9 2.0 2.9 2.0 2.9 2.0 2.9 2.0 2.8 1.9 2.7 1.9 3.7 2.3 3.7 2.3 3.7 2.3 3.7 2.3 3.7 2.3 3.7 2.3 3.7 2.3 3.7 2.3 3.7 2.3 3.7 2.3 3.7 2.3 3.7 2.3 3.7 2.3 3.7 2.3 3.6 2.2 3.5 2.2 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.5 3.0 4.4 2.9 SHC : Sensible capacity [kW] o 22.0 CWB o 30 CDB TC SHC 2.4 1.7 2.4 1.7 2.4 1.7 2.4 1.7 2.4 1.7 2.4 1.7 2.4 1.7 2.4 1.7 2.4 1.7 2.4 1.7 2.4 1.7 2.4 1.7 2.4 1.7 2.4 1.7 2.3 1.6 2.3 1.6 3.1 2.0 3.1 2.0 3.1 2.0 3.1 2.0 3.1 2.0 3.1 2.0 3.1 2.0 3.1 2.0 3.1 2.0 3.1 2.0 3.1 2.0 3.1 2.0 3.1 2.0 3.1 2.0 3.0 1.9 2.9 1.9 3.9 2.3 3.9 2.3 3.9 2.3 3.9 2.3 3.9 2.3 3.9 2.3 3.9 2.3 3.9 2.3 3.9 2.3 3.9 2.3 3.9 2.3 3.9 2.3 3.9 2.3 3.9 2.3 3.8 2.2 3.7 2.1 4.9 3.0 4.9 3.0 4.9 3.0 4.9 3.0 4.9 3.0 4.9 3.0 4.9 3.0 4.9 3.0 4.9 3.0 4.9 3.0 4.9 3.0 4.9 3.0 4.9 3.0 4.9 3.0 4.7 2.9 4.6 2.8 o 24.0 CWB o 32 CDB TC SHC 2.5 1.6 2.5 1.6 2.5 1.6 2.5 1.6 2.5 1.6 2.5 1.6 2.5 1.6 2.5 1.6 2.5 1.6 2.5 1.6 2.5 1.6 2.5 1.6 2.5 1.6 2.5 1.6 2.4 1.6 2.4 1.5 3.2 1.9 3.2 1.9 3.2 1.9 3.2 1.9 3.2 1.9 3.2 1.9 3.2 1.9 3.2 1.9 3.2 1.9 3.2 1.9 3.2 1.9 3.2 1.9 3.2 1.9 3.2 1.9 3.1 1.9 3.0 1.8 4.1 2.2 4.1 2.2 4.1 2.2 4.1 2.2 4.1 2.2 4.1 2.2 4.1 2.2 4.1 2.2 4.1 2.2 4.1 2.2 4.1 2.2 4.1 2.2 4.1 2.2 4.1 2.2 4.0 2.2 3.9 2.1 5.1 3.0 5.1 3.0 5.1 3.0 5.1 3.0 5.1 3.0 5.1 3.0 5.1 3.0 5.1 3.0 5.1 3.0 5.1 3.0 5.1 3.0 5.1 3.0 5.1 3.0 5.1 3.0 5.0 2.9 4.8 2.8 2-way Air Discharge Cassette Type ( MMU-AP****WH) TC : Total capacity [kW] unit size 018 024 027 030 outdoor air temp. o CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 o 14.0 CWB o 20 CDB TC SHC 4.6 3.4 4.6 3.4 4.6 3.4 4.6 3.4 4.6 3.4 4.6 3.4 4.6 3.4 4.6 3.4 4.6 3.4 4.6 3.4 4.6 3.4 4.6 3.4 4.6 3.4 4.6 3.4 4.5 3.3 4.3 3.2 5.8 4.3 5.8 4.3 5.8 4.3 5.8 4.3 5.8 4.3 5.8 4.3 5.8 4.3 5.8 4.3 5.8 4.3 5.8 4.3 5.8 4.3 5.8 4.3 5.8 4.3 5.8 4.3 5.6 4.1 5.5 4.0 6.6 4.9 6.6 4.9 6.6 4.9 6.6 4.9 6.6 4.9 6.6 4.9 6.6 4.9 6.6 4.9 6.6 4.9 6.6 4.9 6.6 4.9 6.6 4.9 6.6 4.9 6.6 4.9 6.4 4.7 6.2 4.6 7.4 5.3 7.4 5.3 7.4 5.3 7.4 5.3 7.4 5.3 7.4 5.3 7.4 5.3 7.4 5.3 7.4 5.3 7.4 5.3 7.4 5.3 7.4 5.3 7.4 5.3 7.4 5.3 7.2 5.1 7.0 5.0 o 16.0 CWB o 23 CDB TC SHC 5.1 3.6 5.1 3.6 5.1 3.6 5.1 3.6 5.1 3.6 5.1 3.6 5.1 3.6 5.1 3.6 5.1 3.6 5.1 3.6 5.1 3.6 5.1 3.6 5.1 3.6 5.1 3.6 4.9 3.5 4.8 3.4 6.4 4.5 6.4 4.5 6.4 4.5 6.4 4.5 6.4 4.5 6.4 4.5 6.4 4.5 6.4 4.5 6.4 4.5 6.4 4.5 6.4 4.5 6.4 4.5 6.4 4.5 6.4 4.5 6.2 4.4 6.1 4.3 7.3 5.2 7.3 5.2 7.3 5.2 7.3 5.2 7.3 5.2 7.3 5.2 7.3 5.2 7.3 5.2 7.3 5.2 7.3 5.2 7.3 5.2 7.3 5.2 7.3 5.2 7.3 5.2 7.0 5.0 6.8 4.9 8.2 5.7 8.2 5.7 8.2 5.7 8.2 5.7 8.2 5.7 8.2 5.7 8.2 5.7 8.2 5.7 8.2 5.7 8.2 5.7 8.2 5.7 8.2 5.7 8.2 5.7 8.2 5.7 7.9 5.5 7.7 5.3 indoor air temp. o o 18.0 CWB 19.0 CWB o o 26 CDB 27 CDB TC SHC TC SHC 5.4 3.8 5.6 3.8 5.4 3.8 5.6 3.8 5.4 3.8 5.6 3.8 5.4 3.8 5.6 3.8 5.4 3.8 5.6 3.8 5.4 3.8 5.6 3.8 5.4 3.8 5.6 3.8 5.4 3.8 5.6 3.8 5.4 3.8 5.6 3.8 5.4 3.8 5.6 3.8 5.4 3.8 5.6 3.8 5.4 3.8 5.6 3.8 5.4 3.8 5.6 3.8 5.4 3.8 5.6 3.8 5.3 3.7 5.4 3.7 5.1 3.6 5.3 3.6 6.9 4.8 7.1 4.8 6.9 4.8 7.1 4.8 6.9 4.8 7.1 4.8 6.9 4.8 7.1 4.8 6.9 4.8 7.1 4.8 6.9 4.8 7.1 4.8 6.9 4.8 7.1 4.8 6.9 4.8 7.1 4.8 6.9 4.8 7.1 4.8 6.9 4.8 7.1 4.8 6.9 4.8 7.1 4.8 6.9 4.8 7.1 4.8 6.9 4.8 7.1 4.8 6.9 4.8 7.1 4.8 6.7 4.7 6.9 4.6 6.5 4.5 6.7 4.5 7.8 5.5 8.0 5.5 7.8 5.5 8.0 5.5 7.8 5.5 8.0 5.5 7.8 5.5 8.0 5.5 7.8 5.5 8.0 5.5 7.8 5.5 8.0 5.5 7.8 5.5 8.0 5.5 7.8 5.5 8.0 5.5 7.8 5.5 8.0 5.5 7.8 5.5 8.0 5.5 7.8 5.5 8.0 5.5 7.8 5.5 8.0 5.5 7.8 5.5 8.0 5.5 7.8 5.5 8.0 5.5 7.5 5.3 7.7 5.3 7.3 5.2 7.5 5.2 8.7 6.0 9.0 6.0 8.7 6.0 9.0 6.0 8.7 6.0 9.0 6.0 8.7 6.0 9.0 6.0 8.7 6.0 9.0 6.0 8.7 6.0 9.0 6.0 8.7 6.0 9.0 6.0 8.7 6.0 9.0 6.0 8.7 6.0 9.0 6.0 8.7 6.0 9.0 6.0 8.7 6.0 9.0 6.0 8.7 6.0 9.0 6.0 8.7 6.0 9.0 6.0 8.7 6.0 9.0 6.0 8.5 5.8 8.7 5.8 8.2 5.7 8.5 5.6 o 20.0 CWB o 28 CDB TC SHC 5.8 3.8 5.8 3.8 5.8 3.8 5.8 3.8 5.8 3.8 5.8 3.8 5.8 3.8 5.8 3.8 5.8 3.8 5.8 3.8 5.8 3.8 5.8 3.8 5.8 3.8 5.8 3.8 5.6 3.7 5.4 3.6 7.3 4.8 7.3 4.8 7.3 4.8 7.3 4.8 7.3 4.8 7.3 4.8 7.3 4.8 7.3 4.8 7.3 4.8 7.3 4.8 7.3 4.8 7.3 4.8 7.3 4.8 7.3 4.8 7.1 4.6 6.9 4.5 8.2 5.5 8.2 5.5 8.2 5.5 8.2 5.5 8.2 5.5 8.2 5.5 8.2 5.5 8.2 5.5 8.2 5.5 8.2 5.5 8.2 5.5 8.2 5.5 8.2 5.5 8.2 5.5 8.0 5.3 7.8 5.2 9.3 6.0 9.3 6.0 9.3 6.0 9.3 6.0 9.3 6.0 9.3 6.0 9.3 6.0 9.3 6.0 9.3 6.0 9.3 6.0 9.3 6.0 9.3 6.0 9.3 6.0 9.3 6.0 9.0 5.8 8.7 5.6 SHC : Sensible capacity [kW] o 22.0 CWB o 30 CDB TC SHC 6.1 3.8 6.1 3.8 6.1 3.8 6.1 3.8 6.1 3.8 6.1 3.8 6.1 3.8 6.1 3.8 6.1 3.8 6.1 3.8 6.1 3.8 6.1 3.8 6.1 3.8 6.1 3.8 5.9 3.6 5.7 3.5 7.7 4.8 7.7 4.8 7.7 4.8 7.7 4.8 7.7 4.8 7.7 4.8 7.7 4.8 7.7 4.8 7.7 4.8 7.7 4.8 7.7 4.8 7.7 4.8 7.7 4.8 7.7 4.8 7.5 4.6 7.3 4.5 8.7 5.4 8.7 5.4 8.7 5.4 8.7 5.4 8.7 5.4 8.7 5.4 8.7 5.4 8.7 5.4 8.7 5.4 8.7 5.4 8.7 5.4 8.7 5.4 8.7 5.4 8.7 5.4 8.4 5.3 8.2 5.1 9.8 5.9 9.8 5.9 9.8 5.9 9.8 5.9 9.8 5.9 9.8 5.9 9.8 5.9 9.8 5.9 9.8 5.9 9.8 5.9 9.8 5.9 9.8 5.9 9.8 5.9 9.8 5.9 9.5 5.8 9.2 5.6 o 24.0 CWB o 32 CDB TC SHC 6.4 3.7 6.4 3.7 6.4 3.7 6.4 3.7 6.4 3.7 6.4 3.7 6.4 3.7 6.4 3.7 6.4 3.7 6.4 3.7 6.4 3.7 6.4 3.7 6.4 3.7 6.4 3.7 6.2 3.6 6.0 3.5 8.1 4.6 8.1 4.6 8.1 4.6 8.1 4.6 8.1 4.6 8.1 4.6 8.1 4.6 8.1 4.6 8.1 4.6 8.1 4.6 8.1 4.6 8.1 4.6 8.1 4.6 8.1 4.6 7.8 4.5 7.6 4.4 9.1 5.3 9.1 5.3 9.1 5.3 9.1 5.3 9.1 5.3 9.1 5.3 9.1 5.3 9.1 5.3 9.1 5.3 9.1 5.3 9.1 5.3 9.1 5.3 9.1 5.3 9.1 5.3 8.8 5.2 8.6 5.0 10.3 5.8 10.3 5.8 10.3 5.8 10.3 5.8 10.3 5.8 10.3 5.8 10.3 5.8 10.3 5.8 10.3 5.8 10.3 5.8 10.3 5.8 10.3 5.8 10.3 5.8 10.3 5.8 9.9 5.6 9.7 5.5 8 49 2-way Air Discharge Cassette Type ( MMU-AP****WH) TC : Total capacity [kW] unit size 048 8 50 outdoor air temp. o CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 o 14.0 CWB o 20 CDB TC SHC 11.5 8.4 11.5 8.4 11.5 8.4 11.5 8.4 11.5 8.4 11.5 8.4 11.5 8.4 11.5 8.4 11.5 8.4 11.5 8.4 11.5 8.4 11.5 8.4 11.5 8.4 11.5 8.4 11.1 8.2 10.8 7.9 o 16.0 CWB o 23 CDB TC SHC 12.7 9.0 12.7 9.0 12.7 9.0 12.7 9.0 12.7 9.0 12.7 9.0 12.7 9.0 12.7 9.0 12.7 9.0 12.7 9.0 12.7 9.0 12.7 9.0 12.7 9.0 12.7 9.0 12.3 8.7 12.0 8.4 indoor air temp. o o 18.0 CWB 19.0 CWB o o 26 CDB 27 CDB TC SHC TC SHC 13.6 9.5 14.0 9.5 13.6 9.5 14.0 9.5 13.6 9.5 14.0 9.5 13.6 9.5 14.0 9.5 13.6 9.5 14.0 9.5 13.6 9.5 14.0 9.5 13.6 9.5 14.0 9.5 13.6 9.5 14.0 9.5 13.6 9.5 14.0 9.5 13.6 9.5 14.0 9.5 13.6 9.5 14.0 9.5 13.6 9.5 14.0 9.5 13.6 9.5 14.0 9.5 13.6 9.5 14.0 9.5 13.1 9.2 13.6 9.2 12.8 9.0 13.2 8.9 o 20.0 CWB o 28 CDB TC SHC 14.4 9.5 14.4 9.5 14.4 9.5 14.4 9.5 14.4 9.5 14.4 9.5 14.4 9.5 14.4 9.5 14.4 9.5 14.4 9.5 14.4 9.5 14.4 9.5 14.4 9.5 14.4 9.5 14.0 9.2 13.6 8.9 SHC : Sensible capacity [kW] o 22.0 CWB o 30 CDB TC SHC 15.3 9.4 15.3 9.4 15.3 9.4 15.3 9.4 15.3 9.4 15.3 9.4 15.3 9.4 15.3 9.4 15.3 9.4 15.3 9.4 15.3 9.4 15.3 9.4 15.3 9.4 15.3 9.4 14.8 9.1 14.4 8.9 o 24.0 CWB o 32 CDB TC SHC 16.0 9.2 16.0 9.2 16.0 9.2 16.0 9.2 16.0 9.2 16.0 9.2 16.0 9.2 16.0 9.2 16.0 9.2 16.0 9.2 16.0 9.2 16.0 9.2 16.0 9.2 16.0 9.2 15.4 8.9 15.0 8.7 1-way Air Discharge Cassette Type ( MMU-AP****YH [007 unit size 007 009 012 015 outdoor air temp. o CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 o 14.0 CWB o 20 CDB TC SHC 1.8 1.6 1.8 1.6 1.8 1.6 1.8 1.6 1.8 1.6 1.8 1.6 1.8 1.6 1.8 1.6 1.8 1.6 1.8 1.6 1.8 1.6 1.8 1.6 1.8 1.6 1.8 1.6 1.7 1.5 1.7 1.5 2.3 2.0 2.3 2.0 2.3 2.0 2.3 2.0 2.3 2.0 2.3 2.0 2.3 2.0 2.3 2.0 2.3 2.0 2.3 2.0 2.3 2.0 2.3 2.0 2.3 2.0 2.3 2.0 2.2 1.9 2.2 1.8 3.0 2.4 3.0 2.4 3.0 2.4 3.0 2.4 3.0 2.4 3.0 2.4 3.0 2.4 3.0 2.4 3.0 2.4 3.0 2.4 3.0 2.4 3.0 2.4 3.0 2.4 3.0 2.4 2.9 2.3 2.8 2.3 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.6 2.6 3.5 2.5 o 16.0 CWB o 23 CDB TC SHC 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 2.0 1.7 1.9 1.6 1.9 1.6 2.5 2.1 2.5 2.1 2.5 2.1 2.5 2.1 2.5 2.1 2.5 2.1 2.5 2.1 2.5 2.1 2.5 2.1 2.5 2.1 2.5 2.1 2.5 2.1 2.5 2.1 2.5 2.1 2.5 2.0 2.4 2.0 3.3 2.5 3.3 2.5 3.3 2.5 3.3 2.5 3.3 2.5 3.3 2.5 3.3 2.5 3.3 2.5 3.3 2.5 3.3 2.5 3.3 2.5 3.3 2.5 3.3 2.5 3.3 2.5 3.2 2.5 3.1 2.4 4.1 2.9 4.1 2.9 4.1 2.9 4.1 2.9 4.1 2.9 4.1 2.9 4.1 2.9 4.1 2.9 4.1 2.9 4.1 2.9 4.1 2.9 4.1 2.9 4.1 2.9 4.1 2.9 4.0 2.8 3.8 2.7 012] , -AP****SH [015 TC : Total capacity [kW] indoor air temp. o o o 18.0 CWB 19.0 CWB 20.0 CWB o o o 26 CDB 27 CDB 28 CDB TC SHC TC SHC TC SHC 2.1 1.8 2.2 1.8 2.3 1.8 2.1 1.8 2.2 1.8 2.3 1.8 2.1 1.8 2.2 1.8 2.3 1.8 2.1 1.8 2.2 1.8 2.3 1.8 2.1 1.8 2.2 1.8 2.3 1.8 2.1 1.8 2.2 1.8 2.3 1.8 2.1 1.8 2.2 1.8 2.3 1.8 2.1 1.8 2.2 1.8 2.3 1.8 2.1 1.8 2.2 1.8 2.3 1.8 2.1 1.8 2.2 1.8 2.3 1.8 2.1 1.8 2.2 1.8 2.3 1.8 2.1 1.8 2.2 1.8 2.3 1.8 2.1 1.8 2.2 1.8 2.3 1.8 2.1 1.8 2.2 1.8 2.3 1.8 2.1 1.7 2.1 1.7 2.2 1.7 2.0 1.7 2.1 1.7 2.1 1.7 2.7 2.2 2.8 2.2 2.9 2.2 2.7 2.2 2.8 2.2 2.9 2.2 2.7 2.2 2.8 2.2 2.9 2.2 2.7 2.2 2.8 2.2 2.9 2.2 2.7 2.2 2.8 2.2 2.9 2.2 2.7 2.2 2.8 2.2 2.9 2.2 2.7 2.2 2.8 2.2 2.9 2.2 2.7 2.2 2.8 2.2 2.9 2.2 2.7 2.2 2.8 2.2 2.9 2.2 2.7 2.2 2.8 2.2 2.9 2.2 2.7 2.2 2.8 2.2 2.9 2.2 2.7 2.2 2.8 2.2 2.9 2.2 2.7 2.2 2.8 2.2 2.9 2.2 2.7 2.2 2.8 2.2 2.9 2.2 2.6 2.1 2.7 2.1 2.8 2.1 2.6 2.1 2.6 2.1 2.7 2.1 3.5 2.7 3.6 2.7 3.7 2.7 3.5 2.7 3.6 2.7 3.7 2.7 3.5 2.7 3.6 2.7 3.7 2.7 3.5 2.7 3.6 2.7 3.7 2.7 3.5 2.7 3.6 2.7 3.7 2.7 3.5 2.7 3.6 2.7 3.7 2.7 3.5 2.7 3.6 2.7 3.7 2.7 3.5 2.7 3.6 2.7 3.7 2.7 3.5 2.7 3.6 2.7 3.7 2.7 3.5 2.7 3.6 2.7 3.7 2.7 3.5 2.7 3.6 2.7 3.7 2.7 3.5 2.7 3.6 2.7 3.7 2.7 3.5 2.7 3.6 2.7 3.7 2.7 3.5 2.7 3.6 2.7 3.7 2.7 3.4 2.6 3.5 2.6 3.6 2.6 3.3 2.5 3.4 2.5 3.5 2.5 4.4 3.1 4.5 3.1 4.6 3.1 4.4 3.1 4.5 3.1 4.6 3.1 4.4 3.1 4.5 3.1 4.6 3.1 4.4 3.1 4.5 3.1 4.6 3.1 4.4 3.1 4.5 3.1 4.6 3.1 4.4 3.1 4.5 3.1 4.6 3.1 4.4 3.1 4.5 3.1 4.6 3.1 4.4 3.1 4.5 3.1 4.6 3.1 4.4 3.1 4.5 3.1 4.6 3.1 4.4 3.1 4.5 3.1 4.6 3.1 4.4 3.1 4.5 3.1 4.6 3.1 4.4 3.1 4.5 3.1 4.6 3.1 4.4 3.1 4.5 3.1 4.6 3.1 4.4 3.1 4.5 3.1 4.6 3.1 4.2 3.0 4.4 3.0 4.5 3.0 4.1 2.9 4.2 2.9 4.4 2.9 024] ) SHC : Sensible capacity [kW] o 22.0 CWB o 30 CDB TC SHC 2.4 1.8 2.4 1.8 2.4 1.8 2.4 1.8 2.4 1.8 2.4 1.8 2.4 1.8 2.4 1.8 2.4 1.8 2.4 1.8 2.4 1.8 2.4 1.8 2.4 1.8 2.4 1.8 2.3 1.7 2.3 1.7 3.1 2.2 3.1 2.2 3.1 2.2 3.1 2.2 3.1 2.2 3.1 2.2 3.1 2.2 3.1 2.2 3.1 2.2 3.1 2.2 3.1 2.2 3.1 2.2 3.1 2.2 3.1 2.2 3.0 2.1 2.9 2.1 3.9 2.7 3.9 2.7 3.9 2.7 3.9 2.7 3.9 2.7 3.9 2.7 3.9 2.7 3.9 2.7 3.9 2.7 3.9 2.7 3.9 2.7 3.9 2.7 3.9 2.7 3.9 2.7 3.8 2.6 3.7 2.5 4.9 3.0 4.9 3.0 4.9 3.0 4.9 3.0 4.9 3.0 4.9 3.0 4.9 3.0 4.9 3.0 4.9 3.0 4.9 3.0 4.9 3.0 4.9 3.0 4.9 3.0 4.9 3.0 4.7 2.9 4.6 2.8 o 24.0 CWB o 32 CDB TC SHC 2.5 1.7 2.5 1.7 2.5 1.7 2.5 1.7 2.5 1.7 2.5 1.7 2.5 1.7 2.5 1.7 2.5 1.7 2.5 1.7 2.5 1.7 2.5 1.7 2.5 1.7 2.5 1.7 2.4 1.7 2.4 1.6 3.2 2.1 3.2 2.1 3.2 2.1 3.2 2.1 3.2 2.1 3.2 2.1 3.2 2.1 3.2 2.1 3.2 2.1 3.2 2.1 3.2 2.1 3.2 2.1 3.2 2.1 3.2 2.1 3.1 2.1 3.0 2.0 4.1 2.6 4.1 2.6 4.1 2.6 4.1 2.6 4.1 2.6 4.1 2.6 4.1 2.6 4.1 2.6 4.1 2.6 4.1 2.6 4.1 2.6 4.1 2.6 4.1 2.6 4.1 2.6 4.0 2.5 3.9 2.5 5.1 3.0 5.1 3.0 5.1 3.0 5.1 3.0 5.1 3.0 5.1 3.0 5.1 3.0 5.1 3.0 5.1 3.0 5.1 3.0 5.1 3.0 5.1 3.0 5.1 3.0 5.1 3.0 5.0 2.9 4.8 2.8 8 51 1-way Air Discharge Cassette Type ( MMU-AP****YH [007 unit size 018 8 52 024 outdoor air temp. o CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 o 14.0 CWB o 20 CDB TC SHC 4.6 3.4 4.6 3.4 4.6 3.4 4.6 3.4 4.6 3.4 4.6 3.4 4.6 3.4 4.6 3.4 4.6 3.4 4.6 3.4 4.6 3.4 4.6 3.4 4.6 3.4 4.6 3.4 4.5 3.3 4.3 3.2 5.8 4.4 5.8 4.4 5.8 4.4 5.8 4.4 5.8 4.4 5.8 4.4 5.8 4.4 5.8 4.4 5.8 4.4 5.8 4.4 5.8 4.4 5.8 4.4 5.8 4.4 5.8 4.4 5.6 4.3 5.5 4.2 o 16.0 CWB o 23 CDB TC SHC 5.1 3.6 5.1 3.6 5.1 3.6 5.1 3.6 5.1 3.6 5.1 3.6 5.1 3.6 5.1 3.6 5.1 3.6 5.1 3.6 5.1 3.6 5.1 3.6 5.1 3.6 5.1 3.6 4.9 3.5 4.8 3.4 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.2 4.6 6.1 4.4 012] , -AP****SH [015 TC : Total capacity [kW] indoor air temp. o o o 18.0 CWB 19.0 CWB 20.0 CWB o o o 26 CDB 27 CDB 28 CDB TC SHC TC SHC TC SHC 5.4 3.8 5.6 3.8 5.8 3.8 5.4 3.8 5.6 3.8 5.8 3.8 5.4 3.8 5.6 3.8 5.8 3.8 5.4 3.8 5.6 3.8 5.8 3.8 5.4 3.8 5.6 3.8 5.8 3.8 5.4 3.8 5.6 3.8 5.8 3.8 5.4 3.8 5.6 3.8 5.8 3.8 5.4 3.8 5.6 3.8 5.8 3.8 5.4 3.8 5.6 3.8 5.8 3.8 5.4 3.8 5.6 3.8 5.8 3.8 5.4 3.8 5.6 3.8 5.8 3.8 5.4 3.8 5.6 3.8 5.8 3.8 5.4 3.8 5.6 3.8 5.8 3.8 5.4 3.8 5.6 3.8 5.8 3.8 5.3 3.7 5.4 3.7 5.6 3.7 5.1 3.6 5.3 3.6 5.4 3.6 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.7 4.9 6.9 4.8 7.1 4.8 6.5 4.7 6.7 4.7 6.9 4.7 024] ) SHC : Sensible capacity [kW] o 22.0 CWB o 30 CDB TC SHC 6.1 3.8 6.1 3.8 6.1 3.8 6.1 3.8 6.1 3.8 6.1 3.8 6.1 3.8 6.1 3.8 6.1 3.8 6.1 3.8 6.1 3.8 6.1 3.8 6.1 3.8 6.1 3.8 5.9 3.6 5.7 3.5 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.5 4.8 7.3 4.7 o 24.0 CWB o 32 CDB TC SHC 6.4 3.7 6.4 3.7 6.4 3.7 6.4 3.7 6.4 3.7 6.4 3.7 6.4 3.7 6.4 3.7 6.4 3.7 6.4 3.7 6.4 3.7 6.4 3.7 6.4 3.7 6.4 3.7 6.2 3.6 6.0 3.5 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 7.8 4.7 7.6 4.6 Concealed Duct Standard Type ( MMD-AP****BH ) unit size 007 009 012 015 outdoor air temp. o CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 o 14.0 CWB o 20 CDB TC SHC 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.7 1.5 1.7 1.4 2.3 1.9 2.3 1.9 2.3 1.9 2.3 1.9 2.3 1.9 2.3 1.9 2.3 1.9 2.3 1.9 2.3 1.9 2.3 1.9 2.3 1.9 2.3 1.9 2.3 1.9 2.3 1.9 2.2 1.8 2.2 1.8 3.0 2.2 3.0 2.2 3.0 2.2 3.0 2.2 3.0 2.2 3.0 2.2 3.0 2.2 3.0 2.2 3.0 2.2 3.0 2.2 3.0 2.2 3.0 2.2 3.0 2.2 3.0 2.2 2.9 2.1 2.8 2.1 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.7 2.7 3.6 2.6 3.5 2.5 o 16.0 CWB o 23 CDB TC SHC 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 1.9 1.6 1.9 1.5 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 2.5 1.9 2.4 1.9 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.2 2.3 3.1 2.2 4.1 2.8 4.1 2.8 4.1 2.8 4.1 2.8 4.1 2.8 4.1 2.8 4.1 2.8 4.1 2.8 4.1 2.8 4.1 2.8 4.1 2.8 4.1 2.8 4.1 2.8 4.1 2.8 4.0 2.7 3.8 2.7 TC : Total capacity [kW] indoor air temp. o o o 18.0 CWB 19.0 CWB 20.0 CWB o o o 26 CDB 27 CDB 28 CDB TC SHC TC SHC TC SHC 2.1 1.7 2.2 1.7 2.3 1.7 2.1 1.7 2.2 1.7 2.3 1.7 2.1 1.7 2.2 1.7 2.3 1.7 2.1 1.7 2.2 1.7 2.3 1.7 2.1 1.7 2.2 1.7 2.3 1.7 2.1 1.7 2.2 1.7 2.3 1.7 2.1 1.7 2.2 1.7 2.3 1.7 2.1 1.7 2.2 1.7 2.3 1.7 2.1 1.7 2.2 1.7 2.3 1.7 2.1 1.7 2.2 1.7 2.3 1.7 2.1 1.7 2.2 1.7 2.3 1.7 2.1 1.7 2.2 1.7 2.3 1.7 2.1 1.7 2.2 1.7 2.3 1.7 2.1 1.7 2.2 1.7 2.3 1.7 2.1 1.7 2.1 1.6 2.2 1.6 2.0 1.6 2.1 1.6 2.1 1.6 2.7 2.1 2.8 2.1 2.9 2.1 2.7 2.1 2.8 2.1 2.9 2.1 2.7 2.1 2.8 2.1 2.9 2.1 2.7 2.1 2.8 2.1 2.9 2.1 2.7 2.1 2.8 2.1 2.9 2.1 2.7 2.1 2.8 2.1 2.9 2.1 2.7 2.1 2.8 2.1 2.9 2.1 2.7 2.1 2.8 2.1 2.9 2.1 2.7 2.1 2.8 2.1 2.9 2.1 2.7 2.1 2.8 2.1 2.9 2.1 2.7 2.1 2.8 2.1 2.9 2.1 2.7 2.1 2.8 2.1 2.9 2.1 2.7 2.1 2.8 2.1 2.9 2.1 2.7 2.1 2.8 2.1 2.9 2.1 2.6 2.0 2.7 2.0 2.8 2.0 2.6 2.0 2.6 2.0 2.7 2.0 3.5 2.5 3.6 2.5 3.7 2.5 3.5 2.5 3.6 2.5 3.7 2.5 3.5 2.5 3.6 2.5 3.7 2.5 3.5 2.5 3.6 2.5 3.7 2.5 3.5 2.5 3.6 2.5 3.7 2.5 3.5 2.5 3.6 2.5 3.7 2.5 3.5 2.5 3.6 2.5 3.7 2.5 3.5 2.5 3.6 2.5 3.7 2.5 3.5 2.5 3.6 2.5 3.7 2.5 3.5 2.5 3.6 2.5 3.7 2.5 3.5 2.5 3.6 2.5 3.7 2.5 3.5 2.5 3.6 2.5 3.7 2.5 3.5 2.5 3.6 2.5 3.7 2.5 3.5 2.5 3.6 2.5 3.7 2.5 3.4 2.4 3.5 2.4 3.6 2.4 3.3 2.4 3.4 2.4 3.5 2.4 4.4 3.0 4.5 3.0 4.6 3.0 4.4 3.0 4.5 3.0 4.6 3.0 4.4 3.0 4.5 3.0 4.6 3.0 4.4 3.0 4.5 3.0 4.6 3.0 4.4 3.0 4.5 3.0 4.6 3.0 4.4 3.0 4.5 3.0 4.6 3.0 4.4 3.0 4.5 3.0 4.6 3.0 4.4 3.0 4.5 3.0 4.6 3.0 4.4 3.0 4.5 3.0 4.6 3.0 4.4 3.0 4.5 3.0 4.6 3.0 4.4 3.0 4.5 3.0 4.6 3.0 4.4 3.0 4.5 3.0 4.6 3.0 4.4 3.0 4.5 3.0 4.6 3.0 4.4 3.0 4.5 3.0 4.6 3.0 4.2 2.9 4.4 2.9 4.5 2.9 4.1 2.8 4.2 2.8 4.4 2.8 SHC : Sensible capacity [kW] o 22.0 CWB o 30 CDB TC SHC 2.4 1.7 2.4 1.7 2.4 1.7 2.4 1.7 2.4 1.7 2.4 1.7 2.4 1.7 2.4 1.7 2.4 1.7 2.4 1.7 2.4 1.7 2.4 1.7 2.4 1.7 2.4 1.7 2.3 1.6 2.3 1.6 3.1 2.1 3.1 2.1 3.1 2.1 3.1 2.1 3.1 2.1 3.1 2.1 3.1 2.1 3.1 2.1 3.1 2.1 3.1 2.1 3.1 2.1 3.1 2.1 3.1 2.1 3.1 2.1 3.0 2.0 2.9 2.0 3.9 2.5 3.9 2.5 3.9 2.5 3.9 2.5 3.9 2.5 3.9 2.5 3.9 2.5 3.9 2.5 3.9 2.5 3.9 2.5 3.9 2.5 3.9 2.5 3.9 2.5 3.9 2.5 3.8 2.4 3.7 2.3 4.9 3.0 4.9 3.0 4.9 3.0 4.9 3.0 4.9 3.0 4.9 3.0 4.9 3.0 4.9 3.0 4.9 3.0 4.9 3.0 4.9 3.0 4.9 3.0 4.9 3.0 4.9 3.0 4.7 2.9 4.6 2.8 o 24.0 CWB o 32 CDB TC SHC 2.5 1.6 2.5 1.6 2.5 1.6 2.5 1.6 2.5 1.6 2.5 1.6 2.5 1.6 2.5 1.6 2.5 1.6 2.5 1.6 2.5 1.6 2.5 1.6 2.5 1.6 2.5 1.6 2.4 1.6 2.4 1.5 3.2 2.0 3.2 2.0 3.2 2.0 3.2 2.0 3.2 2.0 3.2 2.0 3.2 2.0 3.2 2.0 3.2 2.0 3.2 2.0 3.2 2.0 3.2 2.0 3.2 2.0 3.2 2.0 3.1 2.0 3.0 1.9 4.1 2.4 4.1 2.4 4.1 2.4 4.1 2.4 4.1 2.4 4.1 2.4 4.1 2.4 4.1 2.4 4.1 2.4 4.1 2.4 4.1 2.4 4.1 2.4 4.1 2.4 4.1 2.4 4.0 2.3 3.9 2.3 5.1 2.9 5.1 2.9 5.1 2.9 5.1 2.9 5.1 2.9 5.1 2.9 5.1 2.9 5.1 2.9 5.1 2.9 5.1 2.9 5.1 2.9 5.1 2.9 5.1 2.9 5.1 2.9 5.0 2.8 4.8 2.7 8 53 Concealed Duct Standard Type ( MMD-AP***BH ) unit size 018 8 024 027 030 54 outdoor air temp. o CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 o 14.0 CWB o 20 CDB TC SHC 4.6 3.3 4.6 3.3 4.6 3.3 4.6 3.3 4.6 3.3 4.6 3.3 4.6 3.3 4.6 3.3 4.6 3.3 4.6 3.3 4.6 3.3 4.6 3.3 4.6 3.3 4.6 3.3 4.5 3.2 4.3 3.1 5.8 4.4 5.8 4.4 5.8 4.4 5.8 4.4 5.8 4.4 5.8 4.4 5.8 4.4 5.8 4.4 5.8 4.4 5.8 4.4 5.8 4.4 5.8 4.4 5.8 4.4 5.8 4.4 5.6 4.3 5.5 4.2 6.6 5.0 6.6 5.0 6.6 5.0 6.6 5.0 6.6 5.0 6.6 5.0 6.6 5.0 6.6 5.0 6.6 5.0 6.6 5.0 6.6 5.0 6.6 5.0 6.6 5.0 6.6 5.0 6.4 4.8 6.2 4.7 7.4 5.5 7.4 5.5 7.4 5.5 7.4 5.5 7.4 5.5 7.4 5.5 7.4 5.5 7.4 5.5 7.4 5.5 7.4 5.5 7.4 5.5 7.4 5.5 7.4 5.5 7.4 5.5 7.2 5.3 7.0 5.2 o 16.0 CWB o 23 CDB TC SHC 5.1 3.5 5.1 3.5 5.1 3.5 5.1 3.5 5.1 3.5 5.1 3.5 5.1 3.5 5.1 3.5 5.1 3.5 5.1 3.5 5.1 3.5 5.1 3.5 5.1 3.5 5.1 3.5 4.9 3.4 4.8 3.3 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.2 4.6 6.1 4.4 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.0 5.1 6.8 5.0 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 8.2 5.9 7.9 5.7 7.7 5.5 TC : Total capacity [kW] indoor air temp. o o o 18.0 CWB 19.0 CWB 20.0 CWB o o o 26 CDB 27 CDB 28 CDB TC SHC TC SHC TC SHC 5.4 3.7 5.6 3.7 5.8 3.7 5.4 3.7 5.6 3.7 5.8 3.7 5.4 3.7 5.6 3.7 5.8 3.7 5.4 3.7 5.6 3.7 5.8 3.7 5.4 3.7 5.6 3.7 5.8 3.7 5.4 3.7 5.6 3.7 5.8 3.7 5.4 3.7 5.6 3.7 5.8 3.7 5.4 3.7 5.6 3.7 5.8 3.7 5.4 3.7 5.6 3.7 5.8 3.7 5.4 3.7 5.6 3.7 5.8 3.7 5.4 3.7 5.6 3.7 5.8 3.7 5.4 3.7 5.6 3.7 5.8 3.7 5.4 3.7 5.6 3.7 5.8 3.7 5.4 3.7 5.6 3.7 5.8 3.7 5.3 3.6 5.4 3.6 5.6 3.6 5.1 3.5 5.3 3.5 5.4 3.5 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.7 4.9 6.9 4.8 7.1 4.8 6.5 4.7 6.7 4.7 6.9 4.7 7.8 5.6 8.0 5.6 8.2 5.6 7.8 5.6 8.0 5.6 8.2 5.6 7.8 5.6 8.0 5.6 8.2 5.6 7.8 5.6 8.0 5.6 8.2 5.6 7.8 5.6 8.0 5.6 8.2 5.6 7.8 5.6 8.0 5.6 8.2 5.6 7.8 5.6 8.0 5.6 8.2 5.6 7.8 5.6 8.0 5.6 8.2 5.6 7.8 5.6 8.0 5.6 8.2 5.6 7.8 5.6 8.0 5.6 8.2 5.6 7.8 5.6 8.0 5.6 8.2 5.6 7.8 5.6 8.0 5.6 8.2 5.6 7.8 5.6 8.0 5.6 8.2 5.6 7.8 5.6 8.0 5.6 8.2 5.6 7.5 5.4 7.7 5.4 8.0 5.4 7.3 5.3 7.5 5.3 7.8 5.3 8.7 6.2 9.0 6.2 9.3 6.2 8.7 6.2 9.0 6.2 9.3 6.2 8.7 6.2 9.0 6.2 9.3 6.2 8.7 6.2 9.0 6.2 9.3 6.2 8.7 6.2 9.0 6.2 9.3 6.2 8.7 6.2 9.0 6.2 9.3 6.2 8.7 6.2 9.0 6.2 9.3 6.2 8.7 6.2 9.0 6.2 9.3 6.2 8.7 6.2 9.0 6.2 9.3 6.2 8.7 6.2 9.0 6.2 9.3 6.2 8.7 6.2 9.0 6.2 9.3 6.2 8.7 6.2 9.0 6.2 9.3 6.2 8.7 6.2 9.0 6.2 9.3 6.2 8.7 6.2 9.0 6.2 9.3 6.2 8.5 6.0 8.7 6.0 9.0 6.0 8.2 5.9 8.5 5.8 8.7 5.8 SHC : Sensible capacity [kW] o 22.0 CWB o 30 CDB TC SHC 6.1 3.7 6.1 3.7 6.1 3.7 6.1 3.7 6.1 3.7 6.1 3.7 6.1 3.7 6.1 3.7 6.1 3.7 6.1 3.7 6.1 3.7 6.1 3.7 6.1 3.7 6.1 3.7 5.9 3.5 5.7 3.4 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.5 4.8 7.3 4.7 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.4 5.4 8.2 5.2 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.8 6.1 9.5 5.9 9.2 5.8 o 24.0 CWB o 32 CDB TC SHC 6.4 3.6 6.4 3.6 6.4 3.6 6.4 3.6 6.4 3.6 6.4 3.6 6.4 3.6 6.4 3.6 6.4 3.6 6.4 3.6 6.4 3.6 6.4 3.6 6.4 3.6 6.4 3.6 6.2 3.5 6.0 3.4 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 7.8 4.7 7.6 4.6 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 8.8 5.2 8.6 5.1 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 10.3 6.0 9.9 5.8 9.7 5.6 Concealed Duct Standard Type ( MMD-AP***BH ) unit size 036 048 056 outdoor air temp. o CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 o 14.0 CWB o 20 CDB TC SHC 9.2 6.5 9.2 6.5 9.2 6.5 9.2 6.5 9.2 6.5 9.2 6.5 9.2 6.5 9.2 6.5 9.2 6.5 9.2 6.5 9.2 6.5 9.2 6.5 9.2 6.5 9.2 6.5 8.9 6.3 8.7 6.1 11.5 8.2 11.5 8.2 11.5 8.2 11.5 8.2 11.5 8.2 11.5 8.2 11.5 8.2 11.5 8.2 11.5 8.2 11.5 8.2 11.5 8.2 11.5 8.2 11.5 8.2 11.5 8.2 11.1 7.9 10.8 7.7 13.1 9.6 13.1 9.6 13.1 9.6 13.1 9.6 13.1 9.6 13.1 9.6 13.1 9.6 13.1 9.6 13.1 9.6 13.1 9.6 13.1 9.6 13.1 9.6 13.1 9.6 13.1 9.6 12.7 9.3 12.4 9.0 o 16.0 CWB o 23 CDB TC SHC 10.2 6.9 10.2 6.9 10.2 6.9 10.2 6.9 10.2 6.9 10.2 6.9 10.2 6.9 10.2 6.9 10.2 6.9 10.2 6.9 10.2 6.9 10.2 6.9 10.2 6.9 10.2 6.9 9.8 6.7 9.6 6.5 12.7 8.7 12.7 8.7 12.7 8.7 12.7 8.7 12.7 8.7 12.7 8.7 12.7 8.7 12.7 8.7 12.7 8.7 12.7 8.7 12.7 8.7 12.7 8.7 12.7 8.7 12.7 8.7 12.3 8.4 12.0 8.2 14.5 10.2 14.5 10.2 14.5 10.2 14.5 10.2 14.5 10.2 14.5 10.2 14.5 10.2 14.5 10.2 14.5 10.2 14.5 10.2 14.5 10.2 14.5 10.2 14.5 10.2 14.5 10.2 14.1 9.9 13.7 9.6 TC : Total capacity [kW] indoor air temp. o o o 18.0 CWB 19.0 CWB 20.0 CWB o o o 26 CDB 27 CDB 28 CDB TC SHC TC SHC TC SHC 10.9 7.3 11.2 7.3 11.5 7.3 10.9 7.3 11.2 7.3 11.5 7.3 10.9 7.3 11.2 7.3 11.5 7.3 10.9 7.3 11.2 7.3 11.5 7.3 10.9 7.3 11.2 7.3 11.5 7.3 10.9 7.3 11.2 7.3 11.5 7.3 10.9 7.3 11.2 7.3 11.5 7.3 10.9 7.3 11.2 7.3 11.5 7.3 10.9 7.3 11.2 7.3 11.5 7.3 10.9 7.3 11.2 7.3 11.5 7.3 10.9 7.3 11.2 7.3 11.5 7.3 10.9 7.3 11.2 7.3 11.5 7.3 10.9 7.3 11.2 7.3 11.5 7.3 10.9 7.3 11.2 7.3 11.5 7.3 10.5 7.1 10.8 7.1 11.2 7.1 10.2 6.9 10.5 6.9 10.9 6.9 13.6 9.2 14.0 9.2 14.4 9.2 13.6 9.2 14.0 9.2 14.4 9.2 13.6 9.2 14.0 9.2 14.4 9.2 13.6 9.2 14.0 9.2 14.4 9.2 13.6 9.2 14.0 9.2 14.4 9.2 13.6 9.2 14.0 9.2 14.4 9.2 13.6 9.2 14.0 9.2 14.4 9.2 13.6 9.2 14.0 9.2 14.4 9.2 13.6 9.2 14.0 9.2 14.4 9.2 13.6 9.2 14.0 9.2 14.4 9.2 13.6 9.2 14.0 9.2 14.4 9.2 13.6 9.2 14.0 9.2 14.4 9.2 13.6 9.2 14.0 9.2 14.4 9.2 13.6 9.2 14.0 9.2 14.4 9.2 13.1 8.9 13.6 8.9 14.0 8.9 12.8 8.7 13.2 8.7 13.6 8.7 15.5 10.8 16.0 10.8 16.5 10.8 15.5 10.8 16.0 10.8 16.5 10.8 15.5 10.8 16.0 10.8 16.5 10.8 15.5 10.8 16.0 10.8 16.5 10.8 15.5 10.8 16.0 10.8 16.5 10.8 15.5 10.8 16.0 10.8 16.5 10.8 15.5 10.8 16.0 10.8 16.5 10.8 15.5 10.8 16.0 10.8 16.5 10.8 15.5 10.8 16.0 10.8 16.5 10.8 15.5 10.8 16.0 10.8 16.5 10.8 15.5 10.8 16.0 10.8 16.5 10.8 15.5 10.8 16.0 10.8 16.5 10.8 15.5 10.8 16.0 10.8 16.5 10.8 15.5 10.8 16.0 10.8 16.5 10.8 15.0 10.5 15.5 10.5 16.0 10.5 14.6 10.2 15.1 10.2 15.5 10.2 SHC : Sensible capacity [kW] o 22.0 CWB o 30 CDB TC SHC 12.2 7.2 12.2 7.2 12.2 7.2 12.2 7.2 12.2 7.2 12.2 7.2 12.2 7.2 12.2 7.2 12.2 7.2 12.2 7.2 12.2 7.2 12.2 7.2 12.2 7.2 12.2 7.2 11.8 7.0 11.5 6.8 15.3 9.1 15.3 9.1 15.3 9.1 15.3 9.1 15.3 9.1 15.3 9.1 15.3 9.1 15.3 9.1 15.3 9.1 15.3 9.1 15.3 9.1 15.3 9.1 15.3 9.1 15.3 9.1 14.8 8.8 14.4 8.6 17.4 10.7 17.4 10.7 17.4 10.7 17.4 10.7 17.4 10.7 17.4 10.7 17.4 10.7 17.4 10.7 17.4 10.7 17.4 10.7 17.4 10.7 17.4 10.7 17.4 10.7 17.4 10.7 16.9 10.4 16.4 10.1 o 24.0 CWB o 32 CDB TC SHC 12.8 7.1 12.8 7.1 12.8 7.1 12.8 7.1 12.8 7.1 12.8 7.1 12.8 7.1 12.8 7.1 12.8 7.1 12.8 7.1 12.8 7.1 12.8 7.1 12.8 7.1 12.8 7.1 12.4 6.8 12.0 6.6 16.0 8.9 16.0 8.9 16.0 8.9 16.0 8.9 16.0 8.9 16.0 8.9 16.0 8.9 16.0 8.9 16.0 8.9 16.0 8.9 16.0 8.9 16.0 8.9 16.0 8.9 16.0 8.9 15.4 8.6 15.0 8.4 18.2 10.5 18.2 10.5 18.2 10.5 18.2 10.5 18.2 10.5 18.2 10.5 18.2 10.5 18.2 10.5 18.2 10.5 18.2 10.5 18.2 10.5 18.2 10.5 18.2 10.5 18.2 10.5 17.7 10.1 17.2 9.8 8 55 Concealed Duct High Static Pressure Type ( MMD-AP****H ) unit size 018 8 024 027 036 56 outdoor air temp. o CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 o 14.0 CWB o 20 CDB TC SHC 4.6 3.6 4.6 3.6 4.6 3.6 4.6 3.6 4.6 3.6 4.6 3.6 4.6 3.6 4.6 3.6 4.6 3.6 4.6 3.6 4.6 3.6 4.6 3.6 4.6 3.6 4.6 3.6 4.5 3.5 4.3 3.4 5.8 4.4 5.8 4.4 5.8 4.4 5.8 4.4 5.8 4.4 5.8 4.4 5.8 4.4 5.8 4.4 5.8 4.4 5.8 4.4 5.8 4.4 5.8 4.4 5.8 4.4 5.8 4.4 5.6 4.3 5.5 4.2 6.6 4.8 6.6 4.8 6.6 4.8 6.6 4.8 6.6 4.8 6.6 4.8 6.6 4.8 6.6 4.8 6.6 4.8 6.6 4.8 6.6 4.8 6.6 4.8 6.6 4.8 6.6 4.8 6.4 4.6 6.2 4.5 9.2 6.9 9.2 6.9 9.2 6.9 9.2 6.9 9.2 6.9 9.2 6.9 9.2 6.9 9.2 6.9 9.2 6.9 9.2 6.9 9.2 6.9 9.2 6.9 9.2 6.9 9.2 6.9 8.9 6.7 8.7 6.5 o 16.0 CWB o 23 CDB TC SHC 5.1 3.8 5.1 3.8 5.1 3.8 5.1 3.8 5.1 3.8 5.1 3.8 5.1 3.8 5.1 3.8 5.1 3.8 5.1 3.8 5.1 3.8 5.1 3.8 5.1 3.8 5.1 3.8 4.9 3.7 4.8 3.6 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.4 4.7 6.2 4.6 6.1 4.4 7.3 5.1 7.3 5.1 7.3 5.1 7.3 5.1 7.3 5.1 7.3 5.1 7.3 5.1 7.3 5.1 7.3 5.1 7.3 5.1 7.3 5.1 7.3 5.1 7.3 5.1 7.3 5.1 7.0 4.9 6.8 4.8 10.2 7.4 10.2 7.4 10.2 7.4 10.2 7.4 10.2 7.4 10.2 7.4 10.2 7.4 10.2 7.4 10.2 7.4 10.2 7.4 10.2 7.4 10.2 7.4 10.2 7.4 10.2 7.4 9.8 7.1 9.6 6.9 TC : Total capacity [kW] indoor air temp. o o o 18.0 CWB 19.0 CWB 20.0 CWB o o o 26 CDB 27 CDB 28 CDB TC SHC TC SHC TC SHC 5.4 4.0 5.6 4.0 5.8 4.0 5.4 4.0 5.6 4.0 5.8 4.0 5.4 4.0 5.6 4.0 5.8 4.0 5.4 4.0 5.6 4.0 5.8 4.0 5.4 4.0 5.6 4.0 5.8 4.0 5.4 4.0 5.6 4.0 5.8 4.0 5.4 4.0 5.6 4.0 5.8 4.0 5.4 4.0 5.6 4.0 5.8 4.0 5.4 4.0 5.6 4.0 5.8 4.0 5.4 4.0 5.6 4.0 5.8 4.0 5.4 4.0 5.6 4.0 5.8 4.0 5.4 4.0 5.6 4.0 5.8 4.0 5.4 4.0 5.6 4.0 5.8 4.0 5.4 4.0 5.6 4.0 5.8 4.0 5.3 3.9 5.4 3.9 5.6 3.9 5.1 3.8 5.3 3.8 5.4 3.8 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.9 5.0 7.1 5.0 7.3 5.0 6.7 4.9 6.9 4.8 7.1 4.8 6.5 4.7 6.7 4.7 6.9 4.7 7.8 5.4 8.0 5.4 8.2 5.4 7.8 5.4 8.0 5.4 8.2 5.4 7.8 5.4 8.0 5.4 8.2 5.4 7.8 5.4 8.0 5.4 8.2 5.4 7.8 5.4 8.0 5.4 8.2 5.4 7.8 5.4 8.0 5.4 8.2 5.4 7.8 5.4 8.0 5.4 8.2 5.4 7.8 5.4 8.0 5.4 8.2 5.4 7.8 5.4 8.0 5.4 8.2 5.4 7.8 5.4 8.0 5.4 8.2 5.4 7.8 5.4 8.0 5.4 8.2 5.4 7.8 5.4 8.0 5.4 8.2 5.4 7.8 5.4 8.0 5.4 8.2 5.4 7.8 5.4 8.0 5.4 8.2 5.4 7.5 5.2 7.7 5.2 8.0 5.2 7.3 5.1 7.5 5.1 7.8 5.1 10.9 7.8 11.2 7.8 11.5 7.8 10.9 7.8 11.2 7.8 11.5 7.8 10.9 7.8 11.2 7.8 11.5 7.8 10.9 7.8 11.2 7.8 11.5 7.8 10.9 7.8 11.2 7.8 11.5 7.8 10.9 7.8 11.2 7.8 11.5 7.8 10.9 7.8 11.2 7.8 11.5 7.8 10.9 7.8 11.2 7.8 11.5 7.8 10.9 7.8 11.2 7.8 11.5 7.8 10.9 7.8 11.2 7.8 11.5 7.8 10.9 7.8 11.2 7.8 11.5 7.8 10.9 7.8 11.2 7.8 11.5 7.8 10.9 7.8 11.2 7.8 11.5 7.8 10.9 7.8 11.2 7.8 11.5 7.8 10.5 7.6 10.8 7.6 11.2 7.5 10.2 7.4 10.5 7.3 10.9 7.3 SHC : Sensible capacity [kW] o 22.0 CWB o 30 CDB TC SHC 6.1 4.0 6.1 4.0 6.1 4.0 6.1 4.0 6.1 4.0 6.1 4.0 6.1 4.0 6.1 4.0 6.1 4.0 6.1 4.0 6.1 4.0 6.1 4.0 6.1 4.0 6.1 4.0 5.9 3.9 5.7 3.8 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.7 5.0 7.5 4.8 7.3 4.7 8.7 5.3 8.7 5.3 8.7 5.3 8.7 5.3 8.7 5.3 8.7 5.3 8.7 5.3 8.7 5.3 8.7 5.3 8.7 5.3 8.7 5.3 8.7 5.3 8.7 5.3 8.7 5.3 8.4 5.2 8.2 5.0 12.2 7.7 12.2 7.7 12.2 7.7 12.2 7.7 12.2 7.7 12.2 7.7 12.2 7.7 12.2 7.7 12.2 7.7 12.2 7.7 12.2 7.7 12.2 7.7 12.2 7.7 12.2 7.7 11.8 7.5 11.5 7.3 o 24.0 CWB o 32 CDB TC SHC 6.4 3.9 6.4 3.9 6.4 3.9 6.4 3.9 6.4 3.9 6.4 3.9 6.4 3.9 6.4 3.9 6.4 3.9 6.4 3.9 6.4 3.9 6.4 3.9 6.4 3.9 6.4 3.9 6.2 3.8 6.0 3.7 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 8.1 4.8 7.8 4.7 7.6 4.6 9.1 5.2 9.1 5.2 9.1 5.2 9.1 5.2 9.1 5.2 9.1 5.2 9.1 5.2 9.1 5.2 9.1 5.2 9.1 5.2 9.1 5.2 9.1 5.2 9.1 5.2 9.1 5.2 8.8 5.1 8.6 4.9 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.8 7.5 12.4 7.3 12.0 7.1 Concealed Duct High Static Pressure Type ( MMD-AP****H ) unit size 048 072 096 outdoor air temp. o CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 o 14.0 CWB o 20 CDB TC SHC 11.5 8.4 11.5 8.4 11.5 8.4 11.5 8.4 11.5 8.4 11.5 8.4 11.5 8.4 11.5 8.4 11.5 8.4 11.5 8.4 11.5 8.4 11.5 8.4 11.5 8.4 11.5 8.4 11.1 8.2 10.8 7.9 18.4 13.2 18.4 13.2 18.4 13.2 18.4 13.2 18.4 13.2 18.4 13.2 18.4 13.2 18.4 13.2 18.4 13.2 18.4 13.2 18.4 13.2 18.4 13.2 18.4 13.2 18.4 13.2 17.8 12.8 17.3 12.4 23.0 16.2 23.0 16.2 23.0 16.2 23.0 16.2 23.0 16.2 23.0 16.2 23.0 16.2 23.0 16.2 23.0 16.2 23.0 16.2 23.0 16.2 23.0 16.2 23.0 16.2 23.0 16.2 22.3 15.7 21.6 15.3 o 16.0 CWB o 23 CDB TC SHC 12.7 9.0 12.7 9.0 12.7 9.0 12.7 9.0 12.7 9.0 12.7 9.0 12.7 9.0 12.7 9.0 12.7 9.0 12.7 9.0 12.7 9.0 12.7 9.0 12.7 9.0 12.7 9.0 12.3 8.7 12.0 8.4 20.3 14.1 20.3 14.1 20.3 14.1 20.3 14.1 20.3 14.1 20.3 14.1 20.3 14.1 20.3 14.1 20.3 14.1 20.3 14.1 20.3 14.1 20.3 14.1 20.3 14.1 20.3 14.1 19.7 13.6 19.1 13.2 25.4 17.3 25.4 17.3 25.4 17.3 25.4 17.3 25.4 17.3 25.4 17.3 25.4 17.3 25.4 17.3 25.4 17.3 25.4 17.3 25.4 17.3 25.4 17.3 25.4 17.3 25.4 17.3 24.6 16.7 23.9 16.3 TC : Total capacity [kW] indoor air temp. o o o 18.0 CWB 19.0 CWB 20.0 CWB o o o 26 CDB 27 CDB 28 CDB TC SHC TC SHC TC SHC 13.6 9.5 14.0 9.5 14.4 9.5 13.6 9.5 14.0 9.5 14.4 9.5 13.6 9.5 14.0 9.5 14.4 9.5 13.6 9.5 14.0 9.5 14.4 9.5 13.6 9.5 14.0 9.5 14.4 9.5 13.6 9.5 14.0 9.5 14.4 9.5 13.6 9.5 14.0 9.5 14.4 9.5 13.6 9.5 14.0 9.5 14.4 9.5 13.6 9.5 14.0 9.5 14.4 9.5 13.6 9.5 14.0 9.5 14.4 9.5 13.6 9.5 14.0 9.5 14.4 9.5 13.6 9.5 14.0 9.5 14.4 9.5 13.6 9.5 14.0 9.5 14.4 9.5 13.6 9.5 14.0 9.5 14.4 9.5 13.1 9.2 13.6 9.2 14.0 9.2 12.8 9.0 13.2 8.9 13.6 8.9 21.7 14.9 22.4 14.9 23.1 14.9 21.7 14.9 22.4 14.9 23.1 14.9 21.7 14.9 22.4 14.9 23.1 14.9 21.7 14.9 22.4 14.9 23.1 14.9 21.7 14.9 22.4 14.9 23.1 14.9 21.7 14.9 22.4 14.9 23.1 14.9 21.7 14.9 22.4 14.9 23.1 14.9 21.7 14.9 22.4 14.9 23.1 14.9 21.7 14.9 22.4 14.9 23.1 14.9 21.7 14.9 22.4 14.9 23.1 14.9 21.7 14.9 22.4 14.9 23.1 14.9 21.7 14.9 22.4 14.9 23.1 14.9 21.7 14.9 22.4 14.9 23.1 14.9 21.7 14.9 22.4 14.9 23.1 14.9 21.0 14.5 21.7 14.4 22.3 14.4 20.4 14.1 21.1 14.0 21.7 14.0 27.2 18.4 28.0 18.3 28.8 18.3 27.2 18.4 28.0 18.3 28.8 18.3 27.2 18.4 28.0 18.3 28.8 18.3 27.2 18.4 28.0 18.3 28.8 18.3 27.2 18.4 28.0 18.3 28.8 18.3 27.2 18.4 28.0 18.3 28.8 18.3 27.2 18.4 28.0 18.3 28.8 18.3 27.2 18.4 28.0 18.3 28.8 18.3 27.2 18.4 28.0 18.3 28.8 18.3 27.2 18.4 28.0 18.3 28.8 18.3 27.2 18.4 28.0 18.3 28.8 18.3 27.2 18.4 28.0 18.3 28.8 18.3 27.2 18.4 28.0 18.3 28.8 18.3 27.2 18.4 28.0 18.3 28.8 18.3 26.3 17.8 18.3 17.7 27.9 17.7 25.6 17.3 26.3 17.2 27.1 17.2 SHC : Sensible capacity [kW] o 22.0 CWB o 30 CDB TC SHC 15.3 9.4 15.3 9.4 15.3 9.4 15.3 9.4 15.3 9.4 15.3 9.4 15.3 9.4 15.3 9.4 15.3 9.4 15.3 9.4 15.3 9.4 15.3 9.4 15.3 9.4 15.3 9.4 14.8 9.1 14.4 8.9 24.4 14.8 24.4 14.8 24.4 14.8 24.4 14.8 24.4 14.8 24.4 14.8 24.4 14.8 24.4 14.8 24.4 14.8 24.4 14.8 24.4 14.8 24.4 14.8 24.4 14.8 24.4 14.8 23.6 14.3 23.0 13.9 30.5 18.1 30.5 18.1 30.5 18.1 30.5 18.1 30.5 18.1 30.5 18.1 30.5 18.1 30.5 18.1 30.5 18.1 30.5 18.1 30.5 18.1 30.5 18.1 30.5 18.1 30.5 18.1 29.5 17.6 28.7 17.1 o 24.0 CWB o 32 CDB TC SHC 16.0 9.2 16.0 9.2 16.0 9.2 16.0 9.2 16.0 9.2 16.0 9.2 16.0 9.2 16.0 9.2 16.0 9.2 16.0 9.2 16.0 9.2 16.0 9.2 16.0 9.2 16.0 9.2 15.4 8.9 15.0 8.7 25.5 14.4 25.5 14.4 25.5 14.4 25.5 14.4 25.5 14.4 25.5 14.4 25.5 14.4 25.5 14.4 25.5 14.4 25.5 14.4 25.5 14.4 25.5 14.4 25.5 14.4 25.5 14.4 24.7 14.0 24.0 13.6 31.9 17.7 31.9 17.7 31.9 17.7 31.9 17.7 31.9 17.7 31.9 17.7 31.9 17.7 31.9 17.7 31.9 17.7 31.9 17.7 31.9 17.7 31.9 17.7 31.9 17.7 31.9 17.7 30.9 17.1 30.0 16.7 8 57 Under Ceiling Type ( MMC-AP****H ) unit size 015 8 018 024 027 58 outdoor air temp. o CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 o 14.0 CWB o 20 CDB TC SHC 3.7 2.8 3.7 2.8 3.7 2.8 3.7 2.8 3.7 2.8 3.7 2.8 3.7 2.8 3.7 2.8 3.7 2.8 3.7 2.8 3.7 2.8 3.7 2.8 3.7 2.8 3.7 2.8 3.6 2.7 3.5 2.7 4.6 3.5 4.6 3.5 4.6 3.5 4.6 3.5 4.6 3.5 4.6 3.5 4.6 3.5 4.6 3.5 4.6 3.5 4.6 3.5 4.6 3.5 4.6 3.5 4.6 3.5 4.6 3.5 4.5 3.3 4.3 3.3 5.8 4.5 5.8 4.5 5.8 4.5 5.8 4.5 5.8 4.5 5.8 4.5 5.8 4.5 5.8 4.5 5.8 4.5 5.8 4.5 5.8 4.5 5.8 4.5 5.8 4.5 5.8 4.5 5.6 4.4 5.5 4.3 6.6 5.0 6.6 5.0 6.6 5.0 6.6 5.0 6.6 5.0 6.6 5.0 6.6 5.0 6.6 5.0 6.6 5.0 6.6 5.0 6.6 5.0 6.6 5.0 6.6 5.0 6.6 5.0 6.4 4.8 6.2 4.7 o 16.0 CWB o 23 CDB TC SHC 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.1 3.0 4.0 2.9 3.8 2.8 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 5.1 3.7 4.9 3.6 4.8 3.5 6.4 4.8 6.4 4.8 6.4 4.8 6.4 4.8 6.4 4.8 6.4 4.8 6.4 4.8 6.4 4.8 6.4 4.8 6.4 4.8 6.4 4.8 6.4 4.8 6.4 4.8 6.4 4.8 6.2 4.7 6.1 4.5 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.3 5.3 7.0 5.1 6.8 5.0 TC : Total capacity [kW] indoor air temp. o o o 18.0 CWB 19.0 CWB 20.0 CWB o o o 26 CDB 27 CDB 28 CDB TC SHC TC SHC TC SHC 4.4 3.2 4.5 3.2 4.6 3.2 4.4 3.2 4.5 3.2 4.6 3.2 4.4 3.2 4.5 3.2 4.6 3.2 4.4 3.2 4.5 3.2 4.6 3.2 4.4 3.2 4.5 3.2 4.6 3.2 4.4 3.2 4.5 3.2 4.6 3.2 4.4 3.2 4.5 3.2 4.6 3.2 4.4 3.2 4.5 3.2 4.6 3.2 4.4 3.2 4.5 3.2 4.6 3.2 4.4 3.2 4.5 3.2 4.6 3.2 4.4 3.2 4.5 3.2 4.6 3.2 4.4 3.2 4.5 3.2 4.6 3.2 4.4 3.2 4.5 3.2 4.6 3.2 4.4 3.2 4.5 3.2 4.6 3.2 4.2 3.1 4.4 3.1 4.5 3.1 4.1 3.0 4.2 3.0 4.4 3.0 5.4 3.9 5.6 3.9 5.8 3.9 5.4 3.9 5.6 3.9 5.8 3.9 5.4 3.9 5.6 3.9 5.8 3.9 5.4 3.9 5.6 3.9 5.8 3.9 5.4 3.9 5.6 3.9 5.8 3.9 5.4 3.9 5.6 3.9 5.8 3.9 5.4 3.9 5.6 3.9 5.8 3.9 5.4 3.9 5.6 3.9 5.8 3.9 5.4 3.9 5.6 3.9 5.8 3.9 5.4 3.9 5.6 3.9 5.8 3.9 5.4 3.9 5.6 3.9 5.8 3.9 5.4 3.9 5.6 3.9 5.8 3.9 5.4 3.9 5.6 3.9 5.8 3.9 5.4 3.9 5.6 3.9 5.8 3.9 5.3 3.8 5.4 3.8 5.6 3.8 5.1 3.7 5.3 3.7 5.4 3.7 6.9 5.1 7.1 5.1 7.3 5.1 6.9 5.1 7.1 5.1 7.3 5.1 6.9 5.1 7.1 5.1 7.3 5.1 6.9 5.1 7.1 5.1 7.3 5.1 6.9 5.1 7.1 5.1 7.3 5.1 6.9 5.1 7.1 5.1 7.3 5.1 6.9 5.1 7.1 5.1 7.3 5.1 6.9 5.1 7.1 5.1 7.3 5.1 6.9 5.1 7.1 5.1 7.3 5.1 6.9 5.1 7.1 5.1 7.3 5.1 6.9 5.1 7.1 5.1 7.3 5.1 6.9 5.1 7.1 5.1 7.3 5.1 6.9 5.1 7.1 5.1 7.3 5.1 6.9 5.1 7.1 5.1 7.3 5.1 6.7 5.0 6.9 4.9 7.1 4.9 6.5 4.8 6.7 4.8 6.9 4.8 7.8 5.6 8.0 5.6 8.2 5.6 7.8 5.6 8.0 5.6 8.2 5.6 7.8 5.6 8.0 5.6 8.2 5.6 7.8 5.6 8.0 5.6 8.2 5.6 7.8 5.6 8.0 5.6 8.2 5.6 7.8 5.6 8.0 5.6 8.2 5.6 7.8 5.6 8.0 5.6 8.2 5.6 7.8 5.6 8.0 5.6 8.2 5.6 7.8 5.6 8.0 5.6 8.2 5.6 7.8 5.6 8.0 5.6 8.2 5.6 7.8 5.6 8.0 5.6 8.2 5.6 7.8 5.6 8.0 5.6 8.2 5.6 7.8 5.6 8.0 5.6 8.2 5.6 7.8 5.6 8.0 5.6 8.2 5.6 7.5 5.4 7.7 5.4 8.0 5.4 7.3 5.3 7.5 5.3 7.8 5.3 SHC : Sensible capacity [kW] o 22.0 CWB o 30 CDB TC SHC 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.9 3.2 4.7 3.1 4.6 3.0 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 6.1 3.9 5.9 3.7 5.7 3.6 7.7 5.1 7.7 5.1 7.7 5.1 7.7 5.1 7.7 5.1 7.7 5.1 7.7 5.1 7.7 5.1 7.7 5.1 7.7 5.1 7.7 5.1 7.7 5.1 7.7 5.1 7.7 5.1 7.5 4.9 7.3 4.8 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.7 5.5 8.4 5.4 8.2 5.2 o 24.0 CWB o 32 CDB TC SHC 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.1 3.1 5.0 3.0 4.8 2.9 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.4 3.8 6.2 3.7 6.0 3.6 8.1 4.9 8.1 4.9 8.1 4.9 8.1 4.9 8.1 4.9 8.1 4.9 8.1 4.9 8.1 4.9 8.1 4.9 8.1 4.9 8.1 4.9 8.1 4.9 8.1 4.9 8.1 4.9 7.8 4.8 7.6 4.6 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 9.1 5.4 8.8 5.2 8.6 5.1 Under Ceiling Type ( MMC-AP****H ) unit size 036 048 outdoor air temp. o CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 o 14.0 CWB o 20 CDB TC SHC 9.2 6.7 9.2 6.7 9.2 6.7 9.2 6.7 9.2 6.7 9.2 6.7 9.2 6.7 9.2 6.7 9.2 6.7 9.2 6.7 9.2 6.7 9.2 6.7 9.2 6.7 9.2 6.7 8.9 6.5 8.7 6.3 11.5 8.7 11.5 8.7 11.5 8.7 11.5 8.7 11.5 8.7 11.5 8.7 11.5 8.7 11.5 8.7 11.5 8.7 11.5 8.7 11.5 8.7 11.5 8.7 11.5 8.7 11.5 8.7 11.1 8.4 10.8 8.2 o 16.0 CWB o 23 CDB TC SHC 10.2 7.2 10.2 7.2 10.2 7.2 10.2 7.2 10.2 7.2 10.2 7.2 10.2 7.2 10.2 7.2 10.2 7.2 10.2 7.2 10.2 7.2 10.2 7.2 10.2 7.2 10.2 7.2 9.8 6.9 9.6 6.8 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.3 9.0 12.0 8.7 TC : Total capacity [kW] indoor air temp. o o o 18.0 CWB 19.0 CWB 20.0 CWB o o o 26 CDB 27 CDB 28 CDB TC SHC TC SHC TC SHC 10.9 7.6 11.2 7.6 11.5 7.6 10.9 7.6 11.2 7.6 11.5 7.6 10.9 7.6 11.2 7.6 11.5 7.6 10.9 7.6 11.2 7.6 11.5 7.6 10.9 7.6 11.2 7.6 11.5 7.6 10.9 7.6 11.2 7.6 11.5 7.6 10.9 7.6 11.2 7.6 11.5 7.6 10.9 7.6 11.2 7.6 11.5 7.6 10.9 7.6 11.2 7.6 11.5 7.6 10.9 7.6 11.2 7.6 11.5 7.6 10.9 7.6 11.2 7.6 11.5 7.6 10.9 7.6 11.2 7.6 11.5 7.6 10.9 7.6 11.2 7.6 11.5 7.6 10.9 7.6 11.2 7.6 11.5 7.6 10.5 7.4 10.8 7.4 11.2 7.4 10.2 7.2 10.5 7.2 10.9 7.2 13.6 9.8 14.0 9.8 14.4 9.8 13.6 9.8 14.0 9.8 14.4 9.8 13.6 9.8 14.0 9.8 14.4 9.8 13.6 9.8 14.0 9.8 14.4 9.8 13.6 9.8 14.0 9.8 14.4 9.8 13.6 9.8 14.0 9.8 14.4 9.8 13.6 9.8 14.0 9.8 14.4 9.8 13.6 9.8 14.0 9.8 14.4 9.8 13.6 9.8 14.0 9.8 14.4 9.8 13.6 9.8 14.0 9.8 14.4 9.8 13.6 9.8 14.0 9.8 14.4 9.8 13.6 9.8 14.0 9.8 14.4 9.8 13.6 9.8 14.0 9.8 14.4 9.8 13.6 9.8 14.0 9.8 14.4 9.8 13.1 9.5 13.6 9.5 14.0 9.5 12.8 9.2 13.2 9.2 13.6 9.2 SHC : Sensible capacity [kW] o 22.0 CWB o 30 CDB TC SHC 12.2 7.5 12.2 7.5 12.2 7.5 12.2 7.5 12.2 7.5 12.2 7.5 12.2 7.5 12.2 7.5 12.2 7.5 12.2 7.5 12.2 7.5 12.2 7.5 12.2 7.5 12.2 7.5 11.8 7.3 11.5 7.1 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 15.3 9.7 14.8 9.4 14.4 9.1 o 24.0 CWB o 32 CDB TC SHC 12.8 7.4 12.8 7.4 12.8 7.4 12.8 7.4 12.8 7.4 12.8 7.4 12.8 7.4 12.8 7.4 12.8 7.4 12.8 7.4 12.8 7.4 12.8 7.4 12.8 7.4 12.8 7.4 12.4 7.1 12.0 6.9 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 16.0 9.5 15.4 9.2 15.0 8.9 8 59 High Wall Type ( MMK-AP****H ) unit size 007 8 009 012 015 60 outdoor air temp. o CDB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 o 14.0 CWB o 20 CDB TC SHC 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.8 1.5 1.7 1.5 1.7 1.4 2.3 1.8 2.3 1.8 2.3 1.8 2.3 1.8 2.3 1.8 2.3 1.8 2.3 1.8 2.3 1.8 2.3 1.8 2.3 1.8 2.3 1.8 2.3 1.8 2.3 1.8 2.3 1.8 2.2 1.7 2.2 1.7 3.0 2.2 3.0 2.2 3.0 2.2 3.0 2.2 3.0 2.2 3.0 2.2 3.0 2.2 3.0 2.2 3.0 2.2 3.0 2.2 3.0 2.2 3.0 2.2 3.0 2.2 3.0 2.2 2.9 2.1 2.8 2.1 3.7 2.6 3.7 2.6 3.7 2.6 3.7 2.6 3.7 2.6 3.7 2.6 3.7 2.6 3.7 2.6 3.7 2.6 3.7 2.6 3.7 2.6 3.7 2.6 3.7 2.6 3.7 2.6 3.6 2.5 3.5 2.4 o 16.0 CWB o 23 CDB TC SHC 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 2.0 1.6 1.9 1.6 1.9 1.5 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.9 2.5 1.8 2.4 1.8 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.3 2.4 3.2 2.3 3.1 2.2 4.1 2.7 4.1 2.7 4.1 2.7 4.1 2.7 4.1 2.7 4.1 2.7 4.1 2.7 4.1 2.7 4.1 2.7 4.1 2.7 4.1 2.7 4.1 2.7 4.1 2.7 4.1 2.7 4.0 2.6 3.8 2.6 TC : Total capacity [kW] indoor air temp. o o o 18.0 CWB 19.0 CWB 20.0 CWB o o o 26 CDB 27 CDB 28 CDB TC SHC TC SHC TC SHC 2.1 1.7 2.2 1.7 2.3 1.7 2.1 1.7 2.2 1.7 2.3 1.7 2.1 1.7 2.2 1.7 2.3 1.7 2.1 1.7 2.2 1.7 2.3 1.7 2.1 1.7 2.2 1.7 2.3 1.7 2.1 1.7 2.2 1.7 2.3 1.7 2.1 1.7 2.2 1.7 2.3 1.7 2.1 1.7 2.2 1.7 2.3 1.7 2.1 1.7 2.2 1.7 2.3 1.7 2.1 1.7 2.2 1.7 2.3 1.7 2.1 1.7 2.2 1.7 2.3 1.7 2.1 1.7 2.2 1.7 2.3 1.7 2.1 1.7 2.2 1.7 2.3 1.7 2.1 1.7 2.2 1.7 2.3 1.7 2.1 1.7 2.1 1.6 2.2 1.6 2.0 1.6 2.1 1.6 2.1 1.6 2.7 2.0 2.8 2.0 2.9 2.0 2.7 2.0 2.8 2.0 2.9 2.0 2.7 2.0 2.8 2.0 2.9 2.0 2.7 2.0 2.8 2.0 2.9 2.0 2.7 2.0 2.8 2.0 2.9 2.0 2.7 2.0 2.8 2.0 2.9 2.0 2.7 2.0 2.8 2.0 2.9 2.0 2.7 2.0 2.8 2.0 2.9 2.0 2.7 2.0 2.8 2.0 2.9 2.0 2.7 2.0 2.8 2.0 2.9 2.0 2.7 2.0 2.8 2.0 2.9 2.0 2.7 2.0 2.8 2.0 2.9 2.0 2.7 2.0 2.8 2.0 2.9 2.0 2.7 2.0 2.8 2.0 2.9 2.0 2.6 1.9 2.7 1.9 2.8 1.9 2.6 1.9 2.6 1.9 2.7 1.9 3.5 2.5 3.6 2.5 3.7 2.5 3.5 2.5 3.6 2.5 3.7 2.5 3.5 2.5 3.6 2.5 3.7 2.5 3.5 2.5 3.6 2.5 3.7 2.5 3.5 2.5 3.6 2.5 3.7 2.5 3.5 2.5 3.6 2.5 3.7 2.5 3.5 2.5 3.6 2.5 3.7 2.5 3.5 2.5 3.6 2.5 3.7 2.5 3.5 2.5 3.6 2.5 3.7 2.5 3.5 2.5 3.6 2.5 3.7 2.5 3.5 2.5 3.6 2.5 3.7 2.5 3.5 2.5 3.6 2.5 3.7 2.5 3.5 2.5 3.6 2.5 3.7 2.5 3.5 2.5 3.6 2.5 3.7 2.5 3.4 2.4 3.5 2.4 3.6 2.4 3.3 2.4 3.4 2.4 3.5 2.4 4.4 2.9 4.5 2.9 4.6 2.9 4.4 2.9 4.5 2.9 4.6 2.9 4.4 2.9 4.5 2.9 4.6 2.9 4.4 2.9 4.5 2.9 4.6 2.9 4.4 2.9 4.5 2.9 4.6 2.9 4.4 2.9 4.5 2.9 4.6 2.9 4.4 2.9 4.5 2.9 4.6 2.9 4.4 2.9 4.5 2.9 4.6 2.9 4.4 2.9 4.5 2.9 4.6 2.9 4.4 2.9 4.5 2.9 4.6 2.9 4.4 2.9 4.5 2.9 4.6 2.9 4.4 2.9 4.5 2.9 4.6 2.9 4.4 2.9 4.5 2.9 4.6 2.9 4.4 2.9 4.5 2.9 4.6 2.9 4.2 2.8 4.4 2.8 4.5 2.8 4.1 2.7 4.2 2.7 4.4 2.7 SHC : Sensible capacity [kW] o 22.0 CWB o 30 CDB TC SHC 2.4 1.7 2.4 1.7 2.4 1.7 2.4 1.7 2.4 1.7 2.4 1.7 2.4 1.7 2.4 1.7 2.4 1.7 2.4 1.7 2.4 1.7 2.4 1.7 2.4 1.7 2.4 1.7 2.3 1.6 2.3 1.6 3.1 2.0 3.1 2.0 3.1 2.0 3.1 2.0 3.1 2.0 3.1 2.0 3.1 2.0 3.1 2.0 3.1 2.0 3.1 2.0 3.1 2.0 3.1 2.0 3.1 2.0 3.1 2.0 3.0 1.9 2.9 1.9 3.9 2.5 3.9 2.5 3.9 2.5 3.9 2.5 3.9 2.5 3.9 2.5 3.9 2.5 3.9 2.5 3.9 2.5 3.9 2.5 3.9 2.5 3.9 2.5 3.9 2.5 3.9 2.5 3.8 2.4 3.7 2.3 4.9 2.9 4.9 2.9 4.9 2.9 4.9 2.9 4.9 2.9 4.9 2.9 4.9 2.9 4.9 2.9 4.9 2.9 4.9 2.9 4.9 2.9 4.9 2.9 4.9 2.9 4.9 2.9 4.7 2.8 4.6 2.7 o 24.0 CWB o 32 CDB TC SHC 2.5 1.6 2.5 1.6 2.5 1.6 2.5 1.6 2.5 1.6 2.5 1.6 2.5 1.6 2.5 1.6 2.5 1.6 2.5 1.6 2.5 1.6 2.5 1.6 2.5 1.6 2.5 1.6 2.4 1.6 2.4 1.5 3.2 1.9 3.2 1.9 3.2 1.9 3.2 1.9 3.2 1.9 3.2 1.9 3.2 1.9 3.2 1.9 3.2 1.9 3.2 1.9 3.2 1.9 3.2 1.9 3.2 1.9 3.2 1.9 3.1 1.9 3.0 1.8 4.1 2.4 4.1 2.4 4.1 2.4 4.1 2.4 4.1 2.4 4.1 2.4 4.1 2.4 4.1 2.4 4.1 2.4 4.1 2.4 4.1 2.4 4.1 2.4 4.1 2.4 4.1 2.4 4.0 2.3 3.9 2.3 5.1 2.8 5.1 2.8 5.1 2.8 5.1 2.8 5.1 2.8 5.1 2.8 5.1 2.8 5.1 2.8 5.1 2.8 5.1 2.8 5.1 2.8 5.1 2.8 5.1 2.8 5.1 2.8 5.0 2.7 4.8 2.6 High Wall Type ( MMK-AP****H ) unit size 018 024 outdoor air temp. o C DB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 o 14.0 CWB o 20 CDB TC SHC 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.6 3.2 4.5 3.1 4.3 3.0 5.8 4.2 5.8 4.2 5.8 4.2 5.8 4.2 5.8 4.2 5.8 4.2 5.8 4.2 5.8 4.2 5.8 4.2 5.8 4.2 5.8 4.2 5.8 4.2 5.8 4.2 5.8 4.2 5.6 4.0 5.5 3.9 o 16.0 CWB o 23 CDB TC SHC 5.1 3.4 5.1 3.4 5.1 3.4 5.1 3.4 5.1 3.4 5.1 3.4 5.1 3.4 5.1 3.4 5.1 3.4 5.1 3.4 5.1 3.4 5.1 3.4 5.1 3.4 5.1 3.4 4.9 3.3 4.8 3.2 6.4 4.4 6.4 4.4 6.4 4.4 6.4 4.4 6.4 4.4 6.4 4.4 6.4 4.4 6.4 4.4 6.4 4.4 6.4 4.4 6.4 4.4 6.4 4.4 6.4 4.4 6.4 4.4 6.2 4.3 6.1 4.2 TC : Total indoor air temp. o o 18.0 CWB 19.0 CWB o o 26 CDB 27 CDB TC SHC TC SHC 5.4 3.6 5.6 3.6 5.4 3.6 5.6 3.6 5.4 3.6 5.6 3.6 5.4 3.6 5.6 3.6 5.4 3.6 5.6 3.6 5.4 3.6 5.6 3.6 5.4 3.6 5.6 3.6 5.4 3.6 5.6 3.6 5.4 3.6 5.6 3.6 5.4 3.6 5.6 3.6 5.4 3.6 5.6 3.6 5.4 3.6 5.6 3.6 5.4 3.6 5.6 3.6 5.4 3.6 5.6 3.6 5.3 3.5 5.4 3.5 5.1 3.4 5.3 3.4 6.9 4.7 7.1 4.7 6.9 4.7 7.1 4.7 6.9 4.7 7.1 4.7 6.9 4.7 7.1 4.7 6.9 4.7 7.1 4.7 6.9 4.7 7.1 4.7 6.9 4.7 7.1 4.7 6.9 4.7 7.1 4.7 6.9 4.7 7.1 4.7 6.9 4.7 7.1 4.7 6.9 4.7 7.1 4.7 6.9 4.7 7.1 4.7 6.9 4.7 7.1 4.7 6.9 4.7 7.1 4.7 6.7 4.6 6.9 4.5 6.5 4.4 6.7 4.4 capacity [kW] o 20.0 CWB o 28 CDB TC SHC 5.8 3.6 5.8 3.6 5.8 3.6 5.8 3.6 5.8 3.6 5.8 3.6 5.8 3.6 5.8 3.6 5.8 3.6 5.8 3.6 5.8 3.6 5.8 3.6 5.8 3.6 5.8 3.6 5.6 3.5 5.4 3.4 7.3 4.7 7.3 4.7 7.3 4.7 7.3 4.7 7.3 4.7 7.3 4.7 7.3 4.7 7.3 4.7 7.3 4.7 7.3 4.7 7.3 4.7 7.3 4.7 7.3 4.7 7.3 4.7 7.1 4.5 6.9 4.4 SHC : Sensible capacity [kW] o 22.0 CWB o 30 CDB TC SHC 6.1 3.6 6.1 3.6 6.1 3.6 6.1 3.6 6.1 3.6 6.1 3.6 6.1 3.6 6.1 3.6 6.1 3.6 6.1 3.6 6.1 3.6 6.1 3.6 6.1 3.6 6.1 3.6 5.9 3.5 5.7 3.4 7.7 4.7 7.7 4.7 7.7 4.7 7.7 4.7 7.7 4.7 7.7 4.7 7.7 4.7 7.7 4.7 7.7 4.7 7.7 4.7 7.7 4.7 7.7 4.7 7.7 4.7 7.7 4.7 7.5 4.5 7.3 4.4 o 24.0 CWB o 32 CDB TC SHC 6.4 3.5 6.4 3.5 6.4 3.5 6.4 3.5 6.4 3.5 6.4 3.5 6.4 3.5 6.4 3.5 6.4 3.5 6.4 3.5 6.4 3.5 6.4 3.5 6.4 3.5 6.4 3.5 6.2 3.4 6.0 3.3 8.1 4.5 8.1 4.5 8.1 4.5 8.1 4.5 8.1 4.5 8.1 4.5 8.1 4.5 8.1 4.5 8.1 4.5 8.1 4.5 8.1 4.5 8.1 4.5 8.1 4.5 8.1 4.5 7.8 4.4 7.6 4.3 8 61 Floor Standing Cabinet Type ( MML-AP****H ) unit size 007 8 009 012 015 62 outdoor air temp. o C DB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 o 14.0 C WB o 20 C DB TC SHC 1.8 1.2 1.8 1.2 1.8 1.2 1.8 1.2 1.8 1.2 1.8 1.2 1.8 1.2 1.8 1.2 1.8 1.2 1.8 1.2 1.8 1.2 1.8 1.2 1.8 1.2 1.8 1.2 1.7 1.2 1.7 1.2 2.3 1.4 2.3 1.4 2.3 1.4 2.3 1.4 2.3 1.4 2.3 1.4 2.3 1.4 2.3 1.4 2.3 1.4 2.3 1.4 2.3 1.4 2.3 1.4 2.3 1.4 2.3 1.4 2.2 1.4 2.2 1.3 3.0 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 2.0 2.9 1.9 2.8 1.8 3.5 2.3 3.5 2.3 3.5 2.3 3.5 2.3 3.5 2.3 3.5 2.3 3.5 2.3 3.5 2.3 3.5 2.3 3.5 2.3 3.5 2.3 3.5 2.3 3.5 2.3 3.6 2.4 3.5 2.3 3.4 2.3 o 16.0 C WB o 23 C DB TC SHC 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 1.9 1.3 1.9 1.2 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.4 1.4 3.3 2.1 3.3 2.1 3.3 2.1 3.3 2.1 3.3 2.1 3.3 2.1 3.3 2.1 3.3 2.1 3.3 2.1 3.3 2.1 3.3 2.1 3.3 2.1 3.3 2.1 3.3 2.1 3.2 2.0 3.1 2.0 3.8 2.5 3.8 2.5 3.8 2.5 3.8 2.5 3.8 2.5 3.8 2.5 3.8 2.5 3.8 2.5 3.8 2.5 3.8 2.5 3.8 2.5 3.8 2.5 3.8 2.5 4.0 2.6 3.8 2.5 3.7 2.4 TC : Total capacity [kW] indoor air temp. o o o 18.0 C WB 19.0 C WB 20.0 C WB o o o 26 C DB 27 C DB 28 C DB TC SHC TC SHC TC SHC 2.1 1.4 2.2 1.4 2.3 1.4 2.1 1.4 2.2 1.4 2.3 1.4 2.1 1.4 2.2 1.4 2.3 1.4 2.1 1.4 2.2 1.4 2.3 1.4 2.1 1.4 2.2 1.4 2.3 1.4 2.1 1.4 2.2 1.4 2.3 1.4 2.1 1.4 2.2 1.4 2.3 1.4 2.1 1.4 2.2 1.4 2.3 1.4 2.1 1.4 2.2 1.4 2.3 1.4 2.1 1.4 2.2 1.4 2.3 1.4 2.1 1.4 2.2 1.4 2.3 1.4 2.1 1.4 2.2 1.4 2.3 1.4 2.1 1.4 2.2 1.4 2.3 1.4 2.1 1.4 2.2 1.4 2.3 1.4 2.1 1.4 2.1 1.4 2.2 1.4 2.0 1.3 2.1 1.3 2.1 1.3 2.7 1.6 2.8 1.6 2.9 1.6 2.7 1.6 2.8 1.6 2.9 1.6 2.7 1.6 2.8 1.6 2.9 1.6 2.7 1.6 2.8 1.6 2.9 1.6 2.7 1.6 2.8 1.6 2.9 1.6 2.7 1.6 2.8 1.6 2.9 1.6 2.7 1.6 2.8 1.6 2.9 1.6 2.7 1.6 2.8 1.6 2.9 1.6 2.7 1.6 2.8 1.6 2.9 1.6 2.7 1.6 2.8 1.6 2.9 1.6 2.7 1.6 2.8 1.6 2.9 1.6 2.7 1.6 2.8 1.6 2.9 1.6 2.7 1.6 2.8 1.6 2.9 1.6 2.7 1.6 2.8 1.6 2.9 1.6 2.6 1.6 2.7 1.5 2.8 1.5 2.6 1.5 2.6 1.5 2.7 1.5 3.5 2.2 3.6 2.2 3.7 2.2 3.5 2.2 3.6 2.2 3.7 2.2 3.5 2.2 3.6 2.2 3.7 2.2 3.5 2.2 3.6 2.2 3.7 2.2 3.5 2.2 3.6 2.2 3.7 2.2 3.5 2.2 3.6 2.2 3.7 2.2 3.5 2.2 3.6 2.2 3.7 2.2 3.5 2.2 3.6 2.2 3.7 2.2 3.5 2.2 3.6 2.2 3.7 2.2 3.5 2.2 3.6 2.2 3.7 2.2 3.5 2.2 3.6 2.2 3.7 2.2 3.5 2.2 3.6 2.2 3.7 2.2 3.5 2.2 3.6 2.2 3.7 2.2 3.5 2.2 3.6 2.2 3.7 2.2 3.4 2.1 3.5 2.1 3.6 2.1 3.3 2.1 3.4 2.1 3.5 2.1 4.1 2.6 4.4 2.7 4.3 2.6 4.1 2.6 4.4 2.7 4.3 2.6 4.1 2.6 4.4 2.7 4.3 2.6 4.1 2.6 4.4 2.7 4.3 2.6 4.1 2.6 4.4 2.7 4.3 2.6 4.1 2.6 4.4 2.7 4.3 2.6 4.1 2.6 4.4 2.7 4.3 2.6 4.1 2.6 4.4 2.7 4.3 2.6 4.1 2.6 4.4 2.7 4.3 2.6 4.1 2.6 4.4 2.7 4.3 2.6 4.1 2.6 4.4 2.7 4.3 2.6 4.1 2.6 4.4 2.7 4.3 2.6 4.1 2.6 4.4 2.7 4.3 2.6 4.2 2.7 4.5 2.8 4.5 2.7 4.1 2.6 4.4 2.7 4.3 2.6 4.0 2.6 4.2 2.6 4.2 2.6 SHC : Sensible capacity [kW] o 22.0 C WB o 30 C DB TC SHC 2.4 1.4 2.4 1.4 2.4 1.4 2.4 1.4 2.4 1.4 2.4 1.4 2.4 1.4 2.4 1.4 2.4 1.4 2.4 1.4 2.4 1.4 2.4 1.4 2.4 1.4 2.4 1.4 2.3 1.3 2.3 1.3 3.1 1.6 3.1 1.6 3.1 1.6 3.1 1.6 3.1 1.6 3.1 1.6 3.1 1.6 3.1 1.6 3.1 1.6 3.1 1.6 3.1 1.6 3.1 1.6 3.1 1.6 3.1 1.6 3.0 1.5 2.9 1.5 3.9 2.2 3.9 2.2 3.9 2.2 3.9 2.2 3.9 2.2 3.9 2.2 3.9 2.2 3.9 2.2 3.9 2.2 3.9 2.2 3.9 2.2 3.9 2.2 3.9 2.2 3.9 2.2 3.8 2.1 3.7 2.1 4.6 2.6 4.6 2.6 4.6 2.6 4.6 2.6 4.6 2.6 4.6 2.6 4.6 2.6 4.6 2.6 4.6 2.6 4.6 2.6 4.6 2.6 4.6 2.6 4.6 2.6 4.7 2.7 4.6 2.6 4.5 2.5 o 24.0 C WB o 32 C DB TC SHC 2.5 1.4 2.5 1.4 2.5 1.4 2.5 1.4 2.5 1.4 2.5 1.4 2.5 1.4 2.5 1.4 2.5 1.4 2.5 1.4 2.5 1.4 2.5 1.4 2.5 1.4 2.5 1.4 2.4 1.3 2.4 1.3 3.2 1.5 3.2 1.5 3.2 1.5 3.2 1.5 3.2 1.5 3.2 1.5 3.2 1.5 3.2 1.5 3.2 1.5 3.2 1.5 3.2 1.5 3.2 1.5 3.2 1.5 3.2 1.5 3.1 1.5 3.0 1.5 4.1 2.1 4.1 2.1 4.1 2.1 4.1 2.1 4.1 2.1 4.1 2.1 4.1 2.1 4.1 2.1 4.1 2.1 4.1 2.1 4.1 2.1 4.1 2.1 4.1 2.1 4.1 2.1 4.0 2.1 3.9 2.0 4.8 2.6 4.8 2.6 4.8 2.6 4.8 2.6 4.8 2.6 4.8 2.6 4.8 2.6 4.8 2.6 4.8 2.6 4.8 2.6 4.8 2.6 4.8 2.6 4.8 2.6 5.0 2.6 4.8 2.6 4.7 2.5 Floor Standing Cabinet Type ( MML-AP****H ) unit size 018 024 outdoor air temp. o C DB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 o 14.0 C WB o 20 C DB TC SHC 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.5 3.0 4.3 2.9 5.8 4.0 5.8 4.0 5.8 4.0 5.8 4.0 5.8 4.0 5.8 4.0 5.8 4.0 5.8 4.0 5.8 4.0 5.8 4.0 5.8 4.0 5.8 4.0 5.8 4.0 5.8 4.0 5.6 3.9 5.5 3.8 o 16.0 C WB o 23 C DB TC SHC 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 4.9 3.2 4.8 3.1 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.2 4.1 6.1 4.0 TC : Total indoor air temp. o o 18.0 C WB 19.0 C WB o o 26 C DB 27 C DB TC SHC TC SHC 5.4 3.5 5.6 3.5 5.4 3.5 5.6 3.5 5.4 3.5 5.6 3.5 5.4 3.5 5.6 3.5 5.4 3.5 5.6 3.5 5.4 3.5 5.6 3.5 5.4 3.5 5.6 3.5 5.4 3.5 5.6 3.5 5.4 3.5 5.6 3.5 5.4 3.5 5.6 3.5 5.4 3.5 5.6 3.5 5.4 3.5 5.6 3.5 5.4 3.5 5.6 3.5 5.4 3.5 5.6 3.5 5.3 3.4 5.4 3.4 5.1 3.3 5.3 3.3 6.9 4.5 7.1 4.5 6.9 4.5 7.1 4.5 6.9 4.5 7.1 4.5 6.9 4.5 7.1 4.5 6.9 4.5 7.1 4.5 6.9 4.5 7.1 4.5 6.9 4.5 7.1 4.5 6.9 4.5 7.1 4.5 6.9 4.5 7.1 4.5 6.9 4.5 7.1 4.5 6.9 4.5 7.1 4.5 6.9 4.5 7.1 4.5 6.9 4.5 7.1 4.5 6.9 4.5 7.1 4.5 6.7 4.4 6.9 4.4 6.5 4.2 6.7 4.2 capacity [kW] o 20.0 C WB o 28 C DB TC SHC 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.6 3.4 5.4 3.3 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.1 4.4 6.9 4.2 SHC : Sensible capacity [kW] o 22.0 C WB o 30 C DB TC SHC 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 5.9 3.4 5.7 3.3 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.5 4.3 7.3 4.2 o 24.0 C WB o 32 C DB TC SHC 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.2 3.3 6.0 3.2 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 7.8 4.2 7.6 4.1 8 63 Floor Standing Concealed Type ( MML-AP****BH ) unit size 007 8 009 012 015 64 outdoor air temp. o C DB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 o 14.0 C WB o 20 C DB TC SHC 1.8 1.2 1.8 1.2 1.8 1.2 1.8 1.2 1.8 1.2 1.8 1.2 1.8 1.2 1.8 1.2 1.8 1.2 1.8 1.2 1.8 1.2 1.8 1.2 1.8 1.2 1.8 1.2 1.7 1.2 1.7 1.2 2.3 1.4 2.3 1.4 2.3 1.4 2.3 1.4 2.3 1.4 2.3 1.4 2.3 1.4 2.3 1.4 2.3 1.4 2.3 1.4 2.3 1.4 2.3 1.4 2.3 1.4 2.3 1.4 2.2 1.4 2.2 1.3 3.0 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 2.0 3.0 2.0 2.9 1.9 2.8 1.8 3.7 2.5 3.7 2.5 3.7 2.5 3.7 2.5 3.7 2.5 3.7 2.5 3.7 2.5 3.7 2.5 3.7 2.5 3.7 2.5 3.7 2.5 3.7 2.5 3.7 2.5 3.7 2.5 3.6 2.4 3.5 2.3 o 16.0 C WB o 23 C DB TC SHC 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 2.0 1.3 1.9 1.3 1.9 1.2 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.5 1.5 2.4 1.4 3.3 2.1 3.3 2.1 3.3 2.1 3.3 2.1 3.3 2.1 3.3 2.1 3.3 2.1 3.3 2.1 3.3 2.1 3.3 2.1 3.3 2.1 3.3 2.1 3.3 2.1 3.3 2.1 3.2 2.0 3.1 2.0 4.1 2.7 4.1 2.7 4.1 2.7 4.1 2.7 4.1 2.7 4.1 2.7 4.1 2.7 4.1 2.7 4.1 2.7 4.1 2.7 4.1 2.7 4.1 2.7 4.1 2.7 4.1 2.7 4.0 2.6 3.8 2.5 TC : Total capacity [kW] indoor air temp. o o o 18.0 C WB 19.0 C WB 20.0 C WB o o o 26 C DB 27 C DB 28 C DB TC SHC TC SHC TC SHC 2.1 1.4 2.2 1.4 2.3 1.4 2.1 1.4 2.2 1.4 2.3 1.4 2.1 1.4 2.2 1.4 2.3 1.4 2.1 1.4 2.2 1.4 2.3 1.4 2.1 1.4 2.2 1.4 2.3 1.4 2.1 1.4 2.2 1.4 2.3 1.4 2.1 1.4 2.2 1.4 2.3 1.4 2.1 1.4 2.2 1.4 2.3 1.4 2.1 1.4 2.2 1.4 2.3 1.4 2.1 1.4 2.2 1.4 2.3 1.4 2.1 1.4 2.2 1.4 2.3 1.4 2.1 1.4 2.2 1.4 2.3 1.4 2.1 1.4 2.2 1.4 2.3 1.4 2.1 1.4 2.2 1.4 2.3 1.4 2.1 1.4 2.1 1.4 2.2 1.4 2.0 1.3 2.1 1.3 2.1 1.3 2.7 1.6 2.8 1.6 2.9 1.6 2.7 1.6 2.8 1.6 2.9 1.6 2.7 1.6 2.8 1.6 2.9 1.6 2.7 1.6 2.8 1.6 2.9 1.6 2.7 1.6 2.8 1.6 2.9 1.6 2.7 1.6 2.8 1.6 2.9 1.6 2.7 1.6 2.8 1.6 2.9 1.6 2.7 1.6 2.8 1.6 2.9 1.6 2.7 1.6 2.8 1.6 2.9 1.6 2.7 1.6 2.8 1.6 2.9 1.6 2.7 1.6 2.8 1.6 2.9 1.6 2.7 1.6 2.8 1.6 2.9 1.6 2.7 1.6 2.8 1.6 2.9 1.6 2.7 1.6 2.8 1.6 2.9 1.6 2.6 1.6 2.7 1.5 2.8 1.5 2.6 1.5 2.6 1.5 2.7 1.5 3.5 2.2 3.6 2.2 3.7 2.2 3.5 2.2 3.6 2.2 3.7 2.2 3.5 2.2 3.6 2.2 3.7 2.2 3.5 2.2 3.6 2.2 3.7 2.2 3.5 2.2 3.6 2.2 3.7 2.2 3.5 2.2 3.6 2.2 3.7 2.2 3.5 2.2 3.6 2.2 3.7 2.2 3.5 2.2 3.6 2.2 3.7 2.2 3.5 2.2 3.6 2.2 3.7 2.2 3.5 2.2 3.6 2.2 3.7 2.2 3.5 2.2 3.6 2.2 3.7 2.2 3.5 2.2 3.6 2.2 3.7 2.2 3.5 2.2 3.6 2.2 3.7 2.2 3.5 2.2 3.6 2.2 3.7 2.2 3.4 2.1 3.5 2.1 3.6 2.1 3.3 2.1 3.4 2.1 3.5 2.1 4.4 2.8 4.5 2.8 4.6 2.8 4.4 2.8 4.5 2.8 4.6 2.8 4.4 2.8 4.5 2.8 4.6 2.8 4.4 2.8 4.5 2.8 4.6 2.8 4.4 2.8 4.5 2.8 4.6 2.8 4.4 2.8 4.5 2.8 4.6 2.8 4.4 2.8 4.5 2.8 4.6 2.8 4.4 2.8 4.5 2.8 4.6 2.8 4.4 2.8 4.5 2.8 4.6 2.8 4.4 2.8 4.5 2.8 4.6 2.8 4.4 2.8 4.5 2.8 4.6 2.8 4.4 2.8 4.5 2.8 4.6 2.8 4.4 2.8 4.5 2.8 4.6 2.8 4.4 2.8 4.5 2.8 4.6 2.8 4.2 2.7 4.4 2.7 4.5 2.7 4.1 2.7 4.2 2.6 4.4 2.6 SHC : Sensible capacity [kW] o 22.0 C WB o 30 C DB TC SHC 2.4 1.4 2.4 1.4 2.4 1.4 2.4 1.4 2.4 1.4 2.4 1.4 2.4 1.4 2.4 1.4 2.4 1.4 2.4 1.4 2.4 1.4 2.4 1.4 2.4 1.4 2.4 1.4 2.3 1.3 2.3 1.3 3.1 1.6 3.1 1.6 3.1 1.6 3.1 1.6 3.1 1.6 3.1 1.6 3.1 1.6 3.1 1.6 3.1 1.6 3.1 1.6 3.1 1.6 3.1 1.6 3.1 1.6 3.1 1.6 3.0 1.5 2.9 1.5 3.9 2.2 3.9 2.2 3.9 2.2 3.9 2.2 3.9 2.2 3.9 2.2 3.9 2.2 3.9 2.2 3.9 2.2 3.9 2.2 3.9 2.2 3.9 2.2 3.9 2.2 3.9 2.2 3.8 2.1 3.7 2.1 4.9 2.8 4.9 2.8 4.9 2.8 4.9 2.8 4.9 2.8 4.9 2.8 4.9 2.8 4.9 2.8 4.9 2.8 4.9 2.8 4.9 2.8 4.9 2.8 4.9 2.8 4.9 2.8 4.7 2.7 4.6 2.6 o 24.0 C WB o 32 C DB TC SHC 2.5 1.4 2.5 1.4 2.5 1.4 2.5 1.4 2.5 1.4 2.5 1.4 2.5 1.4 2.5 1.4 2.5 1.4 2.5 1.4 2.5 1.4 2.5 1.4 2.5 1.4 2.5 1.4 2.4 1.3 2.4 1.3 3.2 1.5 3.2 1.5 3.2 1.5 3.2 1.5 3.2 1.5 3.2 1.5 3.2 1.5 3.2 1.5 3.2 1.5 3.2 1.5 3.2 1.5 3.2 1.5 3.2 1.5 3.2 1.5 3.1 1.5 3.0 1.5 4.1 2.1 4.1 2.1 4.1 2.1 4.1 2.1 4.1 2.1 4.1 2.1 4.1 2.1 4.1 2.1 4.1 2.1 4.1 2.1 4.1 2.1 4.1 2.1 4.1 2.1 4.1 2.1 4.0 2.1 3.9 2.0 5.1 2.7 5.1 2.7 5.1 2.7 5.1 2.7 5.1 2.7 5.1 2.7 5.1 2.7 5.1 2.7 5.1 2.7 5.1 2.7 5.1 2.7 5.1 2.7 5.1 2.7 5.1 2.7 5.0 2.6 4.8 2.6 Floor Standing Concealed Type ( MML-AP****BH ) unit size 018 024 outdoor air temp. o C DB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 o 14.0 CWB o 20 CDB TC SHC 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.6 3.1 4.5 3.0 4.3 2.9 5.8 4.0 5.8 4.0 5.8 4.0 5.8 4.0 5.8 4.0 5.8 4.0 5.8 4.0 5.8 4.0 5.8 4.0 5.8 4.0 5.8 4.0 5.8 4.0 5.8 4.0 5.8 4.0 5.6 3.9 5.5 3.8 o 16.0 CWB o 23 CDB TC SHC 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 4.9 3.2 4.8 3.1 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.4 4.2 6.2 4.1 6.1 4.0 TC : Total indoor air temp. o o 18.0 CWB 19.0 CWB o o 26 CDB 27 CDB TC SHC TC SHC 5.4 3.5 5.6 3.5 5.4 3.5 5.6 3.5 5.4 3.5 5.6 3.5 5.4 3.5 5.6 3.5 5.4 3.5 5.6 3.5 5.4 3.5 5.6 3.5 5.4 3.5 5.6 3.5 5.4 3.5 5.6 3.5 5.4 3.5 5.6 3.5 5.4 3.5 5.6 3.5 5.4 3.5 5.6 3.5 5.4 3.5 5.6 3.5 5.4 3.5 5.6 3.5 5.4 3.5 5.6 3.5 5.3 3.4 5.4 3.4 5.1 3.3 5.3 3.3 6.9 4.5 7.1 4.5 6.9 4.5 7.1 4.5 6.9 4.5 7.1 4.5 6.9 4.5 7.1 4.5 6.9 4.5 7.1 4.5 6.9 4.5 7.1 4.5 6.9 4.5 7.1 4.5 6.9 4.5 7.1 4.5 6.9 4.5 7.1 4.5 6.9 4.5 7.1 4.5 6.9 4.5 7.1 4.5 6.9 4.5 7.1 4.5 6.9 4.5 7.1 4.5 6.9 4.5 7.1 4.5 6.7 4.4 6.9 4.4 6.5 4.2 6.7 4.2 capacity [kW] o 20.0 CWB o 28 CDB TC SHC 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.8 3.5 5.6 3.4 5.4 3.3 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.3 4.5 7.1 4.4 6.9 4.2 SHC : Sensible capacity [kW] o 22.0 CWB o 30 CDB TC SHC 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 6.1 3.5 5.9 3.4 5.7 3.3 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.7 4.5 7.5 4.3 7.3 4.2 o 24.0 CWB o 32 CDB TC SHC 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.4 3.4 6.2 3.3 6.0 3.2 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 8.1 4.4 7.8 4.2 7.6 4.1 8 65 Floor Standing Type ( MMF-AP****H ) unit size 015 8 018 024 027 66 outdoor air temp. o C DB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 o 14.0 C WB o 20 C DB TC SHC 3.7 3.0 3.7 3.0 3.7 3.0 3.7 3.0 3.7 3.0 3.7 3.0 3.7 3.0 3.7 3.0 3.7 3.0 3.7 3.0 3.7 3.0 3.7 3.0 3.7 3.0 3.7 3.0 3.6 2.9 3.5 2.8 4.6 3.6 4.6 3.6 4.6 3.6 4.6 3.6 4.6 3.6 4.6 3.6 4.6 3.6 4.6 3.6 4.6 3.6 4.6 3.6 4.6 3.6 4.6 3.6 4.6 3.6 4.6 3.6 4.5 3.5 4.3 3.4 5.8 4.7 5.8 4.7 5.8 4.7 5.8 4.7 5.8 4.7 5.8 4.7 5.8 4.7 5.8 4.7 5.8 4.7 5.8 4.7 5.8 4.7 5.8 4.7 5.8 4.7 5.8 4.7 5.6 4.5 5.5 4.4 6.6 5.2 6.6 5.2 6.6 5.2 6.6 5.2 6.6 5.2 6.6 5.2 6.6 5.2 6.6 5.2 6.6 5.2 6.6 5.2 6.6 5.2 6.6 5.2 6.6 5.2 6.6 5.2 6.4 5.1 6.2 4.9 o 16.0 C WB o 23 C DB TC SHC 4.1 3.2 4.1 3.2 4.1 3.2 4.1 3.2 4.1 3.2 4.1 3.2 4.1 3.2 4.1 3.2 4.1 3.2 4.1 3.2 4.1 3.2 4.1 3.2 4.1 3.2 4.1 3.2 4.0 3.1 3.8 3.0 5.1 3.9 5.1 3.9 5.1 3.9 5.1 3.9 5.1 3.9 5.1 3.9 5.1 3.9 5.1 3.9 5.1 3.9 5.1 3.9 5.1 3.9 5.1 3.9 5.1 3.9 5.1 3.9 4.9 3.7 4.8 3.6 6.4 5.0 6.4 5.0 6.4 5.0 6.4 5.0 6.4 5.0 6.4 5.0 6.4 5.0 6.4 5.0 6.4 5.0 6.4 5.0 6.4 5.0 6.4 5.0 6.4 5.0 6.4 5.0 6.2 4.8 6.1 4.7 7.3 5.6 7.3 5.6 7.3 5.6 7.3 5.6 7.3 5.6 7.3 5.6 7.3 5.6 7.3 5.6 7.3 5.6 7.3 5.6 7.3 5.6 7.3 5.6 7.3 5.6 7.3 5.6 7.0 5.4 6.8 5.2 TC : Total capacity [kW] indoor air temp. o o o 18.0 C WB 19.0 C WB 20.0 C WB o o o 26 C DB 27 C DB 28 C DB TC SHC TC SHC TC SHC 4.4 3.4 4.5 3.4 4.6 3.4 4.4 3.4 4.5 3.4 4.6 3.4 4.4 3.4 4.5 3.4 4.6 3.4 4.4 3.4 4.5 3.4 4.6 3.4 4.4 3.4 4.5 3.4 4.6 3.4 4.4 3.4 4.5 3.4 4.6 3.4 4.4 3.4 4.5 3.4 4.6 3.4 4.4 3.4 4.5 3.4 4.6 3.4 4.4 3.4 4.5 3.4 4.6 3.4 4.4 3.4 4.5 3.4 4.6 3.4 4.4 3.4 4.5 3.4 4.6 3.4 4.4 3.4 4.5 3.4 4.6 3.4 4.4 3.4 4.5 3.4 4.6 3.4 4.4 3.4 4.5 3.4 4.6 3.4 4.2 3.3 4.4 3.3 4.5 3.3 4.1 3.2 4.2 3.2 4.4 3.2 5.4 4.1 5.6 4.1 5.8 4.1 5.4 4.1 5.6 4.1 5.8 4.1 5.4 4.1 5.6 4.1 5.8 4.1 5.4 4.1 5.6 4.1 5.8 4.1 5.4 4.1 5.6 4.1 5.8 4.1 5.4 4.1 5.6 4.1 5.8 4.1 5.4 4.1 5.6 4.1 5.8 4.1 5.4 4.1 5.6 4.1 5.8 4.1 5.4 4.1 5.6 4.1 5.8 4.1 5.4 4.1 5.6 4.1 5.8 4.1 5.4 4.1 5.6 4.1 5.8 4.1 5.4 4.1 5.6 4.1 5.8 4.1 5.4 4.1 5.6 4.1 5.8 4.1 5.4 4.1 5.6 4.1 5.8 4.1 5.3 4.0 5.4 4.0 5.6 4.0 5.1 3.9 5.3 3.9 5.4 3.9 6.9 5.3 7.1 5.3 7.3 5.3 6.9 5.3 7.1 5.3 7.3 5.3 6.9 5.3 7.1 5.3 7.3 5.3 6.9 5.3 7.1 5.3 7.3 5.3 6.9 5.3 7.1 5.3 7.3 5.3 6.9 5.3 7.1 5.3 7.3 5.3 6.9 5.3 7.1 5.3 7.3 5.3 6.9 5.3 7.1 5.3 7.3 5.3 6.9 5.3 7.1 5.3 7.3 5.3 6.9 5.3 7.1 5.3 7.3 5.3 6.9 5.3 7.1 5.3 7.3 5.3 6.9 5.3 7.1 5.3 7.3 5.3 6.9 5.3 7.1 5.3 7.3 5.3 6.9 5.3 7.1 5.3 7.3 5.3 6.7 5.1 6.9 5.1 7.1 5.1 6.5 5.0 6.7 5.0 6.9 5.0 7.8 5.9 8.0 5.9 8.2 5.9 7.8 5.9 8.0 5.9 8.2 5.9 7.8 5.9 8.0 5.9 8.2 5.9 7.8 5.9 8.0 5.9 8.2 5.9 7.8 5.9 8.0 5.9 8.2 5.9 7.8 5.9 8.0 5.9 8.2 5.9 7.8 5.9 8.0 5.9 8.2 5.9 7.8 5.9 8.0 5.9 8.2 5.9 7.8 5.9 8.0 5.9 8.2 5.9 7.8 5.9 8.0 5.9 8.2 5.9 7.8 5.9 8.0 5.9 8.2 5.9 7.8 5.9 8.0 5.9 8.2 5.9 7.8 5.9 8.0 5.9 8.2 5.9 7.8 5.9 8.0 5.9 8.2 5.9 7.5 5.7 7.7 5.7 8.0 5.7 7.3 5.6 7.5 5.6 7.8 5.6 SHC : Sensible capacity [kW] o 22.0 C WB o 30 C DB TC SHC 4.9 3.4 4.9 3.4 4.9 3.4 4.9 3.4 4.9 3.4 4.9 3.4 4.9 3.4 4.9 3.4 4.9 3.4 4.9 3.4 4.9 3.4 4.9 3.4 4.9 3.4 4.9 3.4 4.7 3.3 4.6 3.2 6.1 4.1 6.1 4.1 6.1 4.1 6.1 4.1 6.1 4.1 6.1 4.1 6.1 4.1 6.1 4.1 6.1 4.1 6.1 4.1 6.1 4.1 6.1 4.1 6.1 4.1 6.1 4.1 5.9 3.9 5.7 3.8 7.7 5.3 7.7 5.3 7.7 5.3 7.7 5.3 7.7 5.3 7.7 5.3 7.7 5.3 7.7 5.3 7.7 5.3 7.7 5.3 7.7 5.3 7.7 5.3 7.7 5.3 7.7 5.3 7.5 5.1 7.3 4.9 8.7 5.8 8.7 5.8 8.7 5.8 8.7 5.8 8.7 5.8 8.7 5.8 8.7 5.8 8.7 5.8 8.7 5.8 8.7 5.8 8.7 5.8 8.7 5.8 8.7 5.8 8.7 5.8 8.4 5.7 8.2 5.5 o 24.0 C WB o 32 C DB TC SHC 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.1 3.3 5.0 3.2 4.8 3.1 6.4 4.0 6.4 4.0 6.4 4.0 6.4 4.0 6.4 4.0 6.4 4.0 6.4 4.0 6.4 4.0 6.4 4.0 6.4 4.0 6.4 4.0 6.4 4.0 6.4 4.0 6.4 4.0 6.2 3.8 6.0 3.7 8.1 5.1 8.1 5.1 8.1 5.1 8.1 5.1 8.1 5.1 8.1 5.1 8.1 5.1 8.1 5.1 8.1 5.1 8.1 5.1 8.1 5.1 8.1 5.1 8.1 5.1 8.1 5.1 7.8 5.0 7.6 4.8 9.1 5.7 9.1 5.7 9.1 5.7 9.1 5.7 9.1 5.7 9.1 5.7 9.1 5.7 9.1 5.7 9.1 5.7 9.1 5.7 9.1 5.7 9.1 5.7 9.1 5.7 9.1 5.7 8.8 5.5 8.6 5.4 Floor Standing Type ( MMF-AP****H ) unit size 036 048 056 outdoor air temp. o C DB 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 o 14.0 C WB o 20 CDB TC SHC 9.2 7.1 9.2 7.1 9.2 7.1 9.2 7.1 9.2 7.1 9.2 7.1 9.2 7.1 9.2 7.1 9.2 7.1 9.2 7.1 9.2 7.1 9.2 7.1 9.2 7.1 9.2 7.1 8.9 6.9 8.7 6.7 11.5 8.8 11.5 8.8 11.5 8.8 11.5 8.8 11.5 8.8 11.5 8.8 11.5 8.8 11.5 8.8 11.5 8.8 11.5 8.8 11.5 8.8 11.5 8.8 11.5 8.8 11.5 8.8 11.1 8.5 10.8 8.3 13.1 10.1 13.1 10.1 13.1 10.1 13.1 10.1 13.1 10.1 13.1 10.1 13.1 10.1 13.1 10.1 13.1 10.1 13.1 10.1 13.1 10.1 13.1 10.1 13.1 10.1 13.1 10.1 12.7 9.8 12.4 9.5 o 16.0 C WB o 23 C DB TC SHC 10.2 7.6 10.2 7.6 10.2 7.6 10.2 7.6 10.2 7.6 10.2 7.6 10.2 7.6 10.2 7.6 10.2 7.6 10.2 7.6 10.2 7.6 10.2 7.6 10.2 7.6 10.2 7.6 9.8 7.3 9.6 7.1 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.7 9.3 12.3 9.0 12.0 8.8 14.5 10.8 14.5 10.8 14.5 10.8 14.5 10.8 14.5 10.8 14.5 10.8 14.5 10.8 14.5 10.8 14.5 10.8 14.5 10.8 14.5 10.8 14.5 10.8 14.5 10.8 14.5 10.8 14.1 10.4 13.7 10.1 TC : Total capacity [kW] indoor air temp. o o o 18.0 C WB 19.0 C WB 20.0 C WB o o o 26 C DB 27 C DB 28 C DB TC SHC TC SHC TC SHC 10.9 8.0 11.2 8.0 11.5 8.0 10.9 8.0 11.2 8.0 11.5 8.0 10.9 8.0 11.2 8.0 11.5 8.0 10.9 8.0 11.2 8.0 11.5 8.0 10.9 8.0 11.2 8.0 11.5 8.0 10.9 8.0 11.2 8.0 11.5 8.0 10.9 8.0 11.2 8.0 11.5 8.0 10.9 8.0 11.2 8.0 11.5 8.0 10.9 8.0 11.2 8.0 11.5 8.0 10.9 8.0 11.2 8.0 11.5 8.0 10.9 8.0 11.2 8.0 11.5 8.0 10.9 8.0 11.2 8.0 11.5 8.0 10.9 8.0 11.2 8.0 11.5 8.0 10.9 8.0 11.2 8.0 11.5 8.0 10.5 7.8 10.8 7.7 11.2 7.7 10.2 7.6 10.5 7.5 10.9 7.5 13.6 9.9 14.0 9.9 14.4 9.9 13.6 9.9 14.0 9.9 14.4 9.9 13.6 9.9 14.0 9.9 14.4 9.9 13.6 9.9 14.0 9.9 14.4 9.9 13.6 9.9 14.0 9.9 14.4 9.9 13.6 9.9 14.0 9.9 14.4 9.9 13.6 9.9 14.0 9.9 14.4 9.9 13.6 9.9 14.0 9.9 14.4 9.9 13.6 9.9 14.0 9.9 14.4 9.9 13.6 9.9 14.0 9.9 14.4 9.9 13.6 9.9 14.0 9.9 14.4 9.9 13.6 9.9 14.0 9.9 14.4 9.9 13.6 9.9 14.0 9.9 14.4 9.9 13.6 9.9 14.0 9.9 14.4 9.9 13.1 9.6 13.6 9.6 14.0 9.6 12.8 9.3 13.2 9.3 13.6 9.3 15.5 11.4 16.0 11.4 16.5 11.4 15.5 11.4 16.0 11.4 16.5 11.4 15.5 11.4 16.0 11.4 16.5 11.4 15.5 11.4 16.0 11.4 16.5 11.4 15.5 11.4 16.0 11.4 16.5 11.4 15.5 11.4 16.0 11.4 16.5 11.4 15.5 11.4 16.0 11.4 16.5 11.4 15.5 11.4 16.0 11.4 16.5 11.4 15.5 11.4 16.0 11.4 16.5 11.4 15.5 11.4 16.0 11.4 16.5 11.4 15.5 11.4 16.0 11.4 16.5 11.4 15.5 11.4 16.0 11.4 16.5 11.4 15.5 11.4 16.0 11.4 16.5 11.4 15.5 11.4 16.0 11.4 16.5 11.4 15.0 11.1 15.5 11.0 16.0 11.0 14.6 10.8 15.1 10.7 15.5 10.7 SHC : Sensible capacity [kW] o 22.0 C WB o 30 C DB TC SHC 12.2 7.9 12.2 7.9 12.2 7.9 12.2 7.9 12.2 7.9 12.2 7.9 12.2 7.9 12.2 7.9 12.2 7.9 12.2 7.9 12.2 7.9 12.2 7.9 12.2 7.9 12.2 7.9 11.8 7.7 11.5 7.5 15.3 9.8 15.3 9.8 15.3 9.8 15.3 9.8 15.3 9.8 15.3 9.8 15.3 9.8 15.3 9.8 15.3 9.8 15.3 9.8 15.3 9.8 15.3 9.8 15.3 9.8 15.3 9.8 14.8 9.5 14.4 9.2 17.4 11.3 17.4 11.3 17.4 11.3 17.4 11.3 17.4 11.3 17.4 11.3 17.4 11.3 17.4 11.3 17.4 11.3 17.4 11.3 17.4 11.3 17.4 11.3 17.4 11.3 17.4 11.3 16.9 10.9 16.4 10.6 o 24.0 C WB o 32 C DB TC SHC 12.8 7.7 12.8 7.7 12.8 7.7 12.8 7.7 12.8 7.7 12.8 7.7 12.8 7.7 12.8 7.7 12.8 7.7 12.8 7.7 12.8 7.7 12.8 7.7 12.8 7.7 12.8 7.7 12.4 7.5 12.0 7.3 16.0 9.6 16.0 9.6 16.0 9.6 16.0 9.6 16.0 9.6 16.0 9.6 16.0 9.6 16.0 9.6 16.0 9.6 16.0 9.6 16.0 9.6 16.0 9.6 16.0 9.6 16.0 9.6 15.4 9.3 15.0 9.0 18.2 11.0 18.2 11.0 18.2 11.0 18.2 11.0 18.2 11.0 18.2 11.0 18.2 11.0 18.2 11.0 18.2 11.0 18.2 11.0 18.2 11.0 18.2 11.0 18.2 11.0 18.2 11.0 17.7 10.7 17.2 10.4 8 67 68 9 Part load performance 69 Foreword 70 9 Foreword Part load performance Part Load Performance MMY-MAP0501 (5HP, 14kW system) Cooling Compressor + Oudoor Fan Power consumption (kW) Outdoor Outdoor 90% 80% 70% 60% 50% 40% 30% Unit Unit 100% 100% Dry-Bulb Cooling Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity ( C) Capacity (kW) 40 C 13.0 3.86 3.16 2.54 2.02 1.59 1.24 1.03 0.88 o o o 14.0 3.65 2.98 2.40 1.90 1.49 1.16 0.96 0.82 o 14.0 3.02 2.48 2.00 1.60 1.27 1.00 0.84 0.73 o 14.0 2.71 2.22 1.80 1.45 1.15 0.92 0.78 0.68 o 14.0 2.52 2.07 1.68 1.35 1.08 0.87 0.74 0.65 o 14.0 2.34 1.93 1.57 1.26 1.01 0.82 0.70 0.61 35 C 30 C 25 C 20 C 15 C Indoor air temperature conditions : 27.0 Heating dry-bulb / 19.0 Compressor + Oudoor Fan wet bulb 9 Power consumption (kW) Outdoor Outdoor 90% 80% 70% 60% 50% 40% 30% Unit Unit 100% 100% Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity Dry-Bulb Heating Capacity ( C) (kW) 16.0 3.35 2.80 2.32 1.90 1.53 1.23 0.99 0.80 15 C o o o 11 C 16.0 3.61 3.01 2.48 2.01 1.61 1.28 1.01 0.81 o 7C 16.0 3.84 3.19 2.62 2.12 1.69 1.32 1.03 0.81 o 1C 14.9 3.90 3.24 2.65 2.14 1.69 1.32 1.02 0.80 o 12.8 3.63 3.02 2.47 1.99 1.58 1.24 0.96 0.75 10.9 3.26 2.72 2.23 1.81 1.44 1.14 0.89 0.71 -5 C o -10 C Indoor air temperature conditions : 20.0 dry-bulb 71 Part Load Performance MMY-MAP0601 (6HP, 16kW system) Cooling Compressor + Oudoor Fan Power consumption (kW) Outdoor Outdoor 90% 80% 70% 60% 50% 40% 30% Unit 100% 100% Unit Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity Cooling Dry-Bulb ( C) Capacity (kW) 40 C 14.9 4.91 4.01 3.23 2.57 2.02 1.58 1.26 1.05 o o o 16.0 4.64 3.79 3.05 2.42 1.90 1.48 1.17 0.97 o 16.0 3.84 3.15 2.55 2.03 1.61 1.28 1.03 0.87 o 16.0 3.44 2.83 2.29 1.84 1.46 1.17 0.95 0.82 o 16.0 3.20 2.63 2.14 1.72 1.37 1.10 0.90 0.78 o 16.0 2.97 2.45 1.99 1.61 1.29 1.04 0.86 0.74 35 C 30 C 25 C 20 C 15 C Indoor air temperature conditions : 27.0 9 Heating dry-bulb / 19.0 Compressor + Oudoor Fan wet bulb Power consumption (kW) Outdoor Outdoor 90% 80% 70% 60% 50% 40% 30% Unit 100% 100% Unit Dry-Bulb Heating Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity ( C) (kW) 15 C 18.0 3.97 3.33 2.76 2.25 1.82 1.46 1.17 0.96 o o o 11 C 18.0 4.28 3.57 2.94 2.39 1.92 1.52 1.20 0.96 o 7C 18.0 4.56 3.79 3.11 2.52 2.00 1.57 1.23 0.97 o 1C 16.7 4.64 3.85 3.15 2.54 2.01 1.57 1.22 0.95 o 14.4 4.31 3.58 2.93 2.37 1.88 1.47 1.14 0.89 12.2 3.87 3.23 2.65 2.15 1.71 1.35 1.06 0.84 -5 C o -10 C Indoor air temperature conditions : 20.0 72 dry-bulb Foreword Part Load Performance MMY-MAP0801 (8HP, 22.4kW system) Cooling Compressor + Oudoor Fan Power consumption (kW) Outdoor Outdoor 90% 80% 70% 60% 50% 40% 30% Unit 100% 100% Unit Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity Cooling Dry-Bulb ( C) Capacity (kW) 40 C 20.8 6.00 4.91 3.95 3.14 2.47 1.93 1.54 1.28 o o o 22.4 5.67 4.63 3.73 2.96 2.32 1.81 1.43 1.19 o 22.4 4.69 3.85 3.11 2.49 1.97 1.56 1.26 1.07 o 22.4 4.20 3.45 2.80 2.25 1.79 1.43 1.16 1.00 o 22.4 3.91 3.21 2.61 2.10 1.68 1.35 1.10 0.95 o 22.4 3.63 2.99 2.44 1.96 1.57 1.27 1.05 0.91 35 C 30 C 25 C 20 C 15 C Indoor air temperature conditions : 27.0 Heating dry-bulb / 19.0 Compressor + Oudoor Fan wet bulb 9 Power consumption (kW) Outdoor Outdoor 90% 80% 70% 60% 50% 40% 30% Unit 100% 100% Unit Dry-Bulb Heating Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity ( C) (kW) 25.0 5.12 4.29 3.55 2.91 2.35 1.89 1.51 1.23 15 C o o o 11 C 25.0 5.52 4.61 3.79 3.08 2.47 1.96 1.55 1.24 o 7C 25.0 5.88 4.89 4.01 3.24 2.58 2.03 1.58 1.25 o 1C 23.3 5.98 4.97 4.06 3.27 2.59 2.02 1.57 1.22 o 20.0 5.55 4.62 3.78 3.05 2.42 1.90 1.47 1.15 17.0 5.00 4.16 3.42 2.77 2.21 1.74 1.37 1.08 -5 C o -10 C Indoor air temperature conditions : 20.0 dry-bulb 73 Part Load Performance MMY-MAP1001 (10HP, 28kW system) Cooling Compressor + Oudoor Fan Power consumption (kW) Outdoor Outdoor 90% 80% 70% 60% 50% 40% 30% Unit 100% 100% Unit Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity Cooling Dry-Bulb ( C) Capacity (kW) 40 C 26.0 8.13 6.65 5.35 4.25 3.34 2.62 2.08 1.73 o o o 28.0 7.68 6.27 5.05 4.00 3.14 2.45 1.94 1.61 o 28.0 6.36 5.21 4.22 3.37 2.67 2.11 1.71 1.45 o 28.0 5.69 4.68 3.79 3.04 2.42 1.93 1.58 1.35 o 28.0 5.29 4.35 3.54 2.84 2.27 1.82 1.50 1.29 o 28.0 4.92 4.05 3.30 2.66 2.13 1.72 1.42 1.23 35 C 30 C 25 C 20 C 15 C Indoor air temperature conditions : 27.0 9 Heating dry-bulb / 19.0 Compressor + Oudoor Fan wet bulb Power consumption (kW) Outdoor Outdoor 90% 80% 70% 60% 50% 40% 30% Unit 100% 100% Unit Dry-Bulb Heating Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity ( C) (kW) 31.5 6.94 5.82 4.82 3.94 3.18 2.56 2.05 1.67 15 C o o o 11 C 31.5 7.49 6.25 5.14 4.18 3.35 2.65 2.10 1.68 o 7C 31.5 7.97 6.63 5.44 4.40 3.50 2.75 2.15 1.69 o 1C 29.3 8.10 6.73 5.51 4.44 3.52 2.74 2.12 1.66 o 25.2 7.53 6.26 5.13 4.13 3.28 2.57 2.00 1.56 21.4 6.77 5.64 4.63 3.75 2.99 2.36 1.85 1.47 -5 C o -10 C Indoor air temperature conditions : 20.0 74 dry-bulb Part Load Performance MMY-MAP1201 (12HP, 33.5kW system) Cooling Compressor + Oudoor Fan Power consumption (kW) Outdoor Outdoor 90% 80% 70% 60% 50% 40% 30% Unit 100% 100% Unit Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity Cooling Dry-Bulb ( C) Capacity (kW) 40 C 31.2 12.61 9.39 7.47 5.82 4.44 3.32 2.48 1.92 o o o 33.5 11.92 8.87 7.05 5.49 4.18 3.12 2.33 1.79 o 33.5 9.87 7.33 5.85 4.57 3.51 2.65 2.01 1.58 o 33.5 8.84 6.56 5.24 4.11 3.17 2.41 1.85 1.47 o 33.5 8.22 6.10 4.88 3.83 2.96 2.26 1.74 1.40 o 33.5 7.64 5.66 4.54 3.57 2.76 2.12 1.64 1.33 35 C 30 C 25 C 20 C 15 C Indoor air temperature conditions : 27.0 Heating dry-bulb / 19.0 Compressor + Oudoor Fan wet bulb 9 Power consumption (kW) Outdoor Outdoor 90% 80% 70% 60% 50% 40% 30% Unit 100% 100% Unit Dry-Bulb Heating Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity ( C) (kW) 37.5 8.88 7.53 6.26 5.14 4.06 3.15 2.42 1.87 15 C o o o 11 C 37.5 9.57 8.12 6.73 5.50 4.31 3.31 2.51 1.90 o 7C 37.5 10.19 8.66 7.16 5.82 4.54 3.46 2.59 1.93 o 1C 34.9 10.36 8.81 7.27 5.90 4.58 3.48 2.58 1.91 o 30.0 9.63 8.18 6.76 5.49 4.27 3.25 2.42 1.79 25.5 8.66 7.35 6.08 4.96 3.87 2.96 2.23 1.67 -5 C o -10 C Indoor air temperature conditions : 20.0 dry-bulb 75 Part Load Performance MMY-AP1601 (16HP, 45kW system) Cooling Compressor + Oudoor Fan Power consumption (kW) Outdoor Outdoor 90% 80% 70% 60% 50% 40% 30% Unit 100% 100% Unit Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity Cooling Dry-Bulb ( C) Capacity (kW) 40 C 41.9 12.91 10.01 8.11 6.48 5.13 4.06 3.27 2.76 o o o 45.0 12.20 9.46 7.66 6.11 4.83 3.82 3.07 2.58 o 45.0 10.10 7.90 6.43 5.17 4.14 3.32 2.72 2.34 o 45.0 9.04 7.11 5.80 4.69 3.78 3.05 2.53 2.20 o 45.0 8.41 6.63 5.42 4.40 3.55 2.89 2.41 2.10 o 45.0 7.82 6.19 5.07 4.13 3.35 2.73 2.29 2.02 35 C 30 C 25 C 20 C 15 C Indoor air temperature conditions : 27.0 9 Heating dry-bulb / 19.0 Compressor + Oudoor Fan wet bulb Power consumption (kW) Outdoor Outdoor 90% 80% 70% 60% 50% 40% 30% Unit 100% 100% Unit Dry-Bulb Heating Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity ( C) (kW) 50.0 10.70 8.80 7.33 6.03 4.92 3.99 3.25 2.69 15 C o o o 11 C 50.0 11.53 9.44 7.81 6.38 5.16 4.14 3.31 2.69 o 7C 50.0 12.28 10.00 8.25 6.71 5.38 4.28 3.39 2.71 o 1C 46.5 12.49 10.15 8.35 6.77 5.41 4.27 3.36 2.66 o 40.0 11.60 9.45 7.78 6.32 5.06 4.01 3.17 2.53 34.0 10.43 8.54 7.06 5.76 4.64 3.70 2.95 2.39 -5 C o -10 C Indoor air temperature conditions : 20.0 76 dry-bulb Part Load Performance MMY-AP2001 (20HP, 56kW system) Cooling Compressor + Oudoor Fan Power consumption (kW) Outdoor Outdoor 90% 80% 70% 60% 50% 40% 30% Unit 100% 100% Unit Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity Cooling Dry-Bulb ( C) Capacity (kW) 40 C 52.1 17.11 13.49 10.91 8.70 6.88 5.43 4.36 3.67 o o o 56.0 16.17 12.75 10.30 8.21 6.48 5.10 4.09 3.43 o 56.0 13.38 10.62 8.63 6.93 5.53 4.42 3.61 3.09 o 56.0 11.99 9.56 7.79 6.28 5.04 4.07 3.35 2.90 o 56.0 10.82 8.66 7.08 5.74 4.63 3.76 3.13 2.73 o 56.0 10.06 8.08 6.62 5.37 4.35 3.55 2.97 2.61 35 C 30 C 25 C 20 C 15 C Indoor air temperature conditions : 27.0 Heating dry-bulb / 19.0 Compressor + Oudoor Fan wet bulb 9 Power consumption (kW) Outdoor Outdoor 90% 80% 70% 60% 50% 40% 30% Unit 100% 100% Unit Dry-Bulb Heating Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity ( C) (kW) 63.0 14.34 11.86 9.85 8.10 6.59 5.33 4.32 3.56 15 C o o o 11 C 63.0 15.46 12.71 10.51 8.57 6.91 5.53 4.41 3.57 o 7C 63.0 16.46 13.48 11.10 9.01 7.22 5.72 4.51 3.60 o 1C 58.6 16.74 13.68 11.24 9.09 7.25 5.71 4.47 3.53 o 50.4 15.55 12.74 10.47 8.49 6.79 5.36 4.21 3.35 42.8 13.98 11.50 9.49 7.72 6.21 4.94 3.93 3.16 -5 C o -10 C Indoor air temperature conditions : 20.0 dry-bulb 77 Part Load Performance MMY-AP2601 (26HP, 73kW system) Cooling Compressor + Oudoor Fan Power consumption (kW) Outdoor Outdoor 90% 80% 70% 60% 50% 40% 30% Unit 100% 100% Unit Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity Cooling Dry-Bulb ( C) Capacity (kW) 40 C 67.9 21.47 16.76 13.56 10.83 8.57 6.78 5.45 4.60 o o o 73.0 20.29 15.84 12.81 10.22 8.07 6.37 5.11 4.29 o 73.0 16.79 13.21 10.74 8.64 6.90 5.53 4.52 3.88 o 73.0 15.04 11.88 9.70 7.83 6.30 5.09 4.20 3.65 o 73.0 13.98 11.08 9.06 7.34 5.93 4.81 4.00 3.49 o 73.0 13.00 10.34 8.47 6.88 5.58 4.55 3.81 3.34 35 C 30 C 25 C 20 C 15 C Indoor air temperature conditions : 27.0 9 Heating dry-bulb / 19.0 Compressor + Oudoor Fan wet bulb Power consumption (kW) Outdoor Outdoor 90% 80% 70% 60% 50% 40% 30% Unit 100% 100% Unit Dry-Bulb Heating Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity ( C) (kW) 81.5 17.87 14.73 12.25 10.08 8.21 6.66 5.41 4.47 15 C o o o 11 C 81.5 19.26 15.79 13.06 10.67 8.62 6.90 5.52 4.48 o 7C 81.5 20.51 16.75 13.80 11.21 8.99 7.14 5.64 4.52 o 1C 75.8 20.86 16.99 13.97 11.31 9.03 7.12 5.59 4.43 o 65.2 19.37 15.82 13.02 10.57 8.46 6.69 5.27 4.20 55.4 17.42 14.29 11.80 9.62 7.74 6.18 4.92 3.96 -5 C o -10 C Indoor air temperature conditions : 20.0 78 dry-bulb Part Load Performance MMY-AP3001 (30HP, 84kW system) Cooling Compressor + Oudoor Fan Power consumption (kW) Outdoor Outdoor 90% 80% 70% 60% 50% 40% 30% Unit 100% 100% Unit Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity Cooling Dry-Bulb ( C) Capacity (kW) 40 C 78.1 25.67 20.24 16.36 13.06 10.32 8.15 6.54 5.50 o o o 84.0 24.26 19.12 15.45 12.31 9.72 7.65 6.13 5.14 o 84.0 20.08 15.94 12.95 10.40 8.30 6.64 5.42 4.64 o 84.0 17.98 14.33 11.68 9.43 7.57 6.10 5.03 4.35 o 84.0 16.72 13.36 10.91 8.83 7.12 5.77 4.79 4.17 o 84.0 15.55 12.46 10.20 8.27 6.69 5.45 4.55 3.99 35 C 30 C 25 C 20 C 15 C Indoor air temperature conditions : 27.0 Heating dry-bulb / 19.0 Compressor + Oudoor Fan wet bulb 9 Power consumption (kW) Outdoor Outdoor 90% 80% 70% 60% 50% 40% 30% Unit 100% 100% Unit Dry-Bulb Heating Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity ( C) (kW) 95.0 21.63 17.78 14.78 12.14 9.88 8.00 6.48 5.34 15 C o o o 11 C 95.0 23.31 19.07 15.76 12.86 10.37 8.29 6.62 5.36 o 7C 95.0 24.82 20.22 16.65 13.52 10.83 8.58 6.77 5.40 o 1C 88.4 25.24 20.52 16.85 13.64 10.88 8.56 6.70 5.30 o 76.0 23.45 19.10 15.71 12.73 10.18 8.04 6.32 5.02 64.6 21.09 17.25 14.23 11.59 9.31 7.41 5.89 4.73 -5 C o -10 C Indoor air temperature conditions : 20.0 dry-bulb 79 Part Load Performance MMY-AP3411 (34HP, 96kW system) Cooling Compressor + Oudoor Fan Power consumption (kW) Outdoor Outdoor 90% 80% 70% 60% 50% 40% 30% Unit 100% 100% Unit Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity Cooling Dry-Bulb ( C) Capacity (kW) 40 C 89.3 35.00 25.73 20.59 16.18 12.51 9.56 7.35 5.87 o o o 96.0 33.08 24.32 19.45 15.28 11.79 9.00 6.90 5.48 o 96.0 27.38 20.18 16.21 12.81 9.98 7.72 6.03 4.91 o 96.0 24.52 18.10 14.58 11.56 9.06 7.06 5.57 4.59 o 96.0 22.80 16.85 13.59 10.80 8.49 6.65 5.28 4.38 o 96.0 21.20 15.68 12.67 10.10 7.96 6.26 5.00 4.18 35 C 30 C 25 C 20 C 15 C Indoor air temperature conditions : 27.0 9 Heating dry-bulb / 19.0 Compressor + Oudoor Fan wet bulb Power consumption (kW) Outdoor Outdoor 90% 80% 70% 60% 50% 40% 30% Unit 100% 100% Unit Dry-Bulb Heating Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity ( C) (kW) 108.0 25.74 21.20 17.66 14.54 11.63 9.19 7.23 5.75 15 C o o o 11 C 108.0 27.74 22.82 18.94 15.50 12.29 9.61 7.44 5.81 o 7C 108.0 29.54 24.28 20.08 16.37 12.90 10.00 7.66 5.89 o 100.4 30.04 24.68 20.38 16.56 13.01 10.03 7.62 5.80 86.4 27.90 22.95 18.97 15.44 12.15 9.39 7.17 5.48 73.4 25.10 20.68 17.13 13.99 11.07 8.61 6.64 5.14 1C o -5 C o -10 C Indoor air temperature conditions : 20.0 80 dry-bulb Part Load Performance MMY-AP4001 (40HP, 112kW system) Cooling Compressor + Oudoor Fan Power consumption (kW) Outdoor Outdoor 90% 80% 70% 60% 50% 40% 30% Unit 100% 100% Unit Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity Cooling Dry-Bulb ( C) Capacity (kW) 40 C 104.2 34.22 26.98 21.82 17.41 13.76 10.86 8.72 7.34 o o o 112.0 32.34 25.49 20.60 16.42 12.95 10.20 8.17 6.85 o 112.0 26.77 21.25 17.26 13.87 11.06 8.85 7.22 6.19 o 112.0 23.97 19.11 15.58 12.57 10.09 8.13 6.71 5.81 o 112.0 22.29 17.82 14.55 11.78 9.49 7.69 6.38 5.56 o 112.0 20.72 16.61 13.60 11.03 8.92 7.27 6.07 5.32 35 C 30 C 25 C 20 C 15 C Indoor air temperature conditions : 27.0 Heating dry-bulb / 19.0 Compressor + Oudoor Fan wet bulb 9 Power consumption (kW) Outdoor Outdoor 90% 80% 70% 60% 50% 40% 30% Unit 100% 100% Unit Dry-Bulb Heating Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity ( C) (kW) 126.5 28.80 23.71 19.70 16.19 13.18 10.66 8.64 7.12 15 C o o o 11 C 126.5 31.04 25.42 21.01 17.15 13.83 11.05 8.83 7.15 o 7C 126.5 33.05 26.96 22.20 18.02 14.44 11.44 9.03 7.20 o 1C 117.6 33.61 27.36 22.47 18.19 14.50 11.42 8.94 7.06 o 101.2 31.22 25.47 20.95 16.98 13.57 10.72 8.43 6.69 86.0 28.08 23.00 18.98 15.45 12.42 9.89 7.85 6.31 -5 C o -10 C Indoor air temperature conditions : 20.0 dry-bulb 81 Part Load Performance MMY-AP4801 (48HP, 135kW system) Cooling Compressor + Oudoor Fan Power consumption (kW) Outdoor Outdoor 90% 80% 70% 60% 50% 40% 30% Unit 100% 100% Unit Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity Cooling Dry-Bulb ( C) Capacity (kW) 40 C 125.6 52.55 37.96 30.27 23.67 18.14 13.70 10.34 8.06 o o o 135.0 49.67 35.89 28.61 22.35 17.11 12.90 9.71 7.54 o 135.0 41.11 29.74 23.79 18.69 14.43 11.02 8.45 6.72 o 135.0 36.82 26.65 21.37 16.84 13.07 10.05 7.78 6.27 o 135.0 34.23 24.79 19.90 15.72 12.24 9.45 7.37 5.98 o 135.0 31.83 23.06 18.54 14.68 11.46 8.89 6.97 5.70 35 C 30 C 25 C 20 C 15 C Indoor air temperature conditions : 27.0 9 Heating dry-bulb / 19.0 Compressor + Oudoor Fan wet bulb Power consumption (kW) Outdoor Outdoor 90% 80% 70% 60% 50% 40% 30% Unit 100% 100% Unit Dry-Bulb Heating Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity ( C) (kW) 150.0 36.42 30.54 25.48 20.98 16.66 13.05 10.14 7.93 15 C o o o 11 C 150.0 39.26 32.93 27.37 22.42 17.67 13.68 10.47 8.04 o 7C 150.0 41.80 35.07 29.06 23.72 18.59 14.28 10.81 8.17 o 1C 139.5 42.50 35.68 29.51 24.04 18.76 14.34 10.77 8.06 o 120.0 39.49 33.17 27.46 22.39 17.51 13.42 10.12 7.61 102.0 35.51 29.85 24.77 20.26 15.92 12.29 9.36 7.13 -5 C o -10 C Indoor air temperature conditions : 20.0 82 dry-bulb 10 Wiring guideline 83 Foreword 84 10 Wiring guideline Foreword WIRING DESIGN 1. General (1) Perform wiring of the power supplies in conformance with the regulations of the local electrical authorities. (2) Use a 2 core shielded wire for control wiring on connecting indoor units, and connecting of indoor units to outdoor units. This is recommended to prevent possible noise issues. (3) Be sure to connect an earth leakage breaker to the power supply of the indoor units. (4) Supply a separate power supply to each outdoor unit ensuring use of an earth leakage breaker and isolator. (5) Never connect 220_240V power to the terminal block (U1, U2, U3, U4, U5, U6) (Fault will be caused.) (6) Locate wiring system for the control and refrigerant piping system in the same line. (7) Arrange the electrical cables so that they do not come in to contact with high-temperature parts of the pipework; otherwise insulation will melt and an accident may be caused. (8) Do not turn on the power supply of the indoor units until vacuuming of the refrigerant pipe has finished. 2. For outdoor unit power supply Select the power supply cabling and fuse of each outdoor unit from the following specifications: 5 core cable in conformance with Design 60245 IEC 66 Do not connect the outdoor units by crossing outside of them, but connect them via the terminal block (L1, L2, L3, N). Outdoor power supply _ 3-phase 380V 415, 50Hz 380V, 60Hz L1 L2 L3 N L1 L2 L3 N L1 L2 L3 N L1 L2 L3 N 3. Electrical wiring design 3-phase 50Hz 380-415V or 60Hz 380V 10 Earth Earth leakage breaker hand switch Outdoor power source Isolator box Indoor power source Single phase 50Hz 220-240V or 60Hz 220V Earth leakage breaker Power switch Model Outdoor power supply MMY-AP T8, HT8 3phase, 380_415 V, 50Hz MMY-AP HT7 3phase, 380 V, 60Hz Unit capacities and power supply wire sizes (Reference) MAP0501T8 MAP0601T8 MAP0801T8 MAP1001T8 MAP1201T8 Model MMYMAP0501HT8 MAP0601HT8 MAP0801HT8 MAP1001HT8 MAP1201HT8 MAP0501HT7 MAP0601HT7 MAP0801HT7 MAP1001HT7 MAP1201HT7 Power supply wiring Wire size Field size 20 A 3.5mm2 (A WG #12) Max. 26 m 2 20 A 3.5mm (A WG #12) Max. 26 m 30 A 3.5mm2 (A WG #10) Max. 20 m 30 A 5.5mm2 (A WG #10) Max. 28 m 5.5mm2 (A WG #10) Max. 27 m 30 A Determine the wire size for the indoor unit according to the number of connected indoor units downstream. Observe local regulations in reference to the wire size selection and installation. 85 4. For Indoor unit power supply (Must be independent from the outdoor unit power supply.) Power supply wiring Item Wire size Model All models of indoor units 2.0m2 (AWG#14) Max. 20m Field fuse 3.5m2 (AWG#12) Max. 50m 15A NOTE : The above connecting lengths stated in the table, indicate the length from the isolator to the outdoor unit. When the power supply of the indoor units are connected in parallel, it is assumed that no more than a 2% voltage drop will occur. If the connecting length is to exceed the stated lengths, select a suitable wire in accordance with the local wiring standards. CAUTIONS (1) Keep the refrigerant piping system and the indoor-indoor/indoor-outdoor control wiring systems together. (2) When running power supplies and control wires parallel to each other, either run them through separate conduits or maintain a suitable distance between them. (Current capacity of power supplies: 10A or less for 300m, 50A or less for 500m) 5. Design of control wiring Power supply Single phase 220-240V 50Hz 220Hz ~ 60Hz (Open) Earth [Central remote controller] (Option) TCB-SC642TLE (For Line 64) Communication wire for control between outdoor units Communication wire for control between outdoor unit and indoor unit Connection of shield wire must be connected (Connected to all connecting sections in each outdoor unit) Connection of shield wire must be connected (Connected to all connecting sections in each indoor unit) 10 Wired remote controller Wire specification, quantity, size of crossover wiring and remote controller wiring Name Crossover wiring (indoor-indoor / indoor-outdoor / outdoor-indoor control wiring, central control wiring) Remote controller wiring Qty 2 cores 2 cores Up to 500m Size Up to 1000m 1.25mm2 0.5 to 2.0mm2 _ 1000 to 2000m Specification 2.0mm2 Shield wire _ _ (1) The crossover wiring and central control wiring uses a 2-core non-polarity communication wire. Use 2-core shielded wire to prevent possible noise issues. Connect the end of the shielded wires and earth(ground) at both the outdoor and indoor unit. Where the shielded wire is connected between a central controller and a outdoor unit, only earth(ground) at one end of the central control line. (2) Use 2-core non-polarity wire for remote controller. (A, B terminals) Use 2-core non-polarity wire for wiring of group control. (A, B terminals) 86 Foreword 6. Control wiring Diagram 1. All control wiring is 2-core non-polarity wire. 2. Be sure to use shield wire for the following wiring to prevent noise issues. Outdoor-outdoor / indoor-indoor / outdoor-indoor control wiring, Central control wiring. Central control device U1 U2 U3 U4 Super modular multi system Header unit Header unit Table-1 L4 Follower unit Follower unit Follower unit Header unit Follower unit U3 U4 U3 U4 U3 U4 U3 U4 U3 U4 U3 U4 U3 U4 U1 U2 U5 U6 U1 U2 U5 U6 U1 U2 U5 U6 U1 U2 U5 U6 U1 U2 U5 U6 U1 U2 U5 U6 U1 U2 U5 U6 Outdoor unit Table-1 L5 L1 Table-2 L2 Indoor unit U1 U2 U1 U2 A B U1 U2 A B L3 U1 U2 A B A B U1 U2 U1 U2 A B Table-3 A B L7 Remote controller Remote controller U1 U2 A B Type Size Length A B L6 Remote controller Table-1 Control wiring between indoor and outdoor units (L1, L2, L3), Central control wiring (L4) Wiring U1 U2 10 2-core, non-polarity Shield wire 1.25 m2 : Up to 1000 m 2.0 m2 : Up to 2000 m (*1) Note (*1) : Total length of control wiring length for all refrigerant circuits ( L1 + L2 + L3 + L4 ) Table-2 Control wiring between outdoor units (L5) Wiring Type Size Length 2-core, non-polarity Shield wire 1.25 m2 to 2.0 m2 Up to 100 m (L5) Table-3 Remote controller wiring (L6, L7) Wire 2-core Size 0.5 m2 Length to 2.0 m2 Up to 500 m ( L6 + L7) Up 400m in case of wireless remote controller in group control. Up to 200m total length of control wiring between indoor units ( L6 ) 87 50Hz Type MMU-AP MMU-AP MMU-AP MMU-AP MMU-AP MMU-AP MMU-AP MMU-AP MMU-AP MMU-AP MMU-AP 2-Way Air MMU-AP Discharge MMU-AP Cassette Type MMU-AP MMU-AP MMU-AP MMU-AP MMU-AP MMU-AP MMU-AP 1-Way Air MMU-AP Discharge MMU-AP Cassette Type MMU-AP MMU-AP MMU-AP MMD-AP Concealed Duct Type MMD-AP MMD-AP MMD-AP MMD-AP MMD-AP MMD-AP MMD-AP MMD-AP MMD-AP MMD-AP MMD-AP Concealed Duct MMD-AP High Static MMD-AP Pressure Type MMD-AP MMD-AP MMD-AP MMD-AP MMC-AP Under Ceiling Type MMC-AP MMC-AP MMC-AP MMC-AP MMC-AP MMK-AP Hige Wall Type MMK-AP MMK-AP MMK-AP MMK-AP MMK-AP MML-AP Floor Standing MML-AP Cabinet Type MML-AP MML-AP MML-AP MML-AP MML-AP Floor Standing MML-AP Concealed Type MML-AP MML-AP MML-AP MML-AP MMF-AP Floor Standing Type MMF-AP MMF-AP MMF-AP MMF-AP MMF-AP MMF-AP 4-Way Air Discharge Cassette Type 10 88 Model 0091 0121 0151 0181 0241 0271 0301 0361 0481 0561 0071 0091 0121 0151 0181 0241 0271 0301 0481 0071 0091 0121 0151 0181 0241 0071 0091 0121 0151 0181 0241 0271 0301 0361 0481 0561 0181 0241 0271 0361 0481 0721 0961 0151 0181 0241 0271 0361 0481 0071 0091 0121 0151 0181 0241 0071 0091 0121 0151 0181 0241 0071 0091 0121 0151 0181 0241 0151 0181 0241 0271 0361 0481 0561 H H H H H H H H H H WH WH WH WH WH WH WH WH WH YH YH YH SH SH SH BH BH BH BH BH BH BH BH BH BH BH H H H H H H H H H H H H H H H H H H H H H H H H H BH BH BH BH BH BH H H H H H H H Nominal Voltage (V-Ph-Hz) 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 220-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 Voltage Range Min Max 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 242 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 198 264 Fan Motor kW FLA 0.060 0.20 0.060 0.20 0.060 0.22 0.060 0.24 0.060 0.28 0.060 0.28 0.060 0.40 0.090 0.68 0.090 0.93 0.090 0.95 0.053 0.36 0.053 0.36 0.053 0.36 0.039 0.37 0.039 0.37 0.053 0.53 0.053 0.53 0.053 0.54 0.092 1.33 0.022 0.28 0.022 0.28 0.022 0.28 0.034 0.55 0.034 0.55 0.034 0.63 0.120 0.33 0.120 0.33 0.120 0.39 0.120 0.39 0.120 0.50 0.120 0.60 0.120 0.60 0.120 0.70 0.120 0.96 0.120 1.13 0.120 1.13 0.160 0.93 0.160 1.55 0.160 1.55 0.260 1.87 0.260 2.12 0.370 x 3 6.04 0.370 x 3 6.35 0.030 0.33 0.030 0.37 0.040 0.48 0.040 0.48 0.080 0.90 0.080 0.96 0.030 0.35 0.030 0.35 0.030 0.35 0.030 0.37 0.030 0.37 0.030 0.40 0.045 0.30 0.045 0.30 0.045 0.49 0.045 0.49 0.070 0.54 0.070 0.54 0.019 0.29 0.019 0.29 0.019 0.29 0.070 0.52 0.070 0.52 0.070 0.53 0.037 0.77 0.037 0.77 0.063 1.01 0.063 1.01 0.110 1.48 0.160 1.84 0.160 1.84 Power Supply MCA MOCP 0.25 15 0.25 15 0.28 15 0.30 15 0.35 15 0.35 15 0.50 15 0.85 15 1.16 15 1.19 15 0.45 15 0.45 15 0.45 15 0.46 15 0.46 15 0.66 15 0.66 15 0.68 15 1.67 15 0.35 15 0.35 15 0.35 15 0.69 15 0.69 15 0.79 15 0.41 15 0.41 15 0.49 15 0.49 15 0.62 15 0.75 15 0.75 15 0.88 15 1.20 15 1.41 15 1.41 15 1.16 15 1.94 15 1.94 15 2.34 15 2.65 15 7.55 15 7.94 15 0.41 15 0.46 15 0.60 15 0.60 15 1.13 15 1.20 15 0.44 15 0.44 15 0.44 15 0.46 15 0.46 15 0.50 15 0.37 15 0.37 15 0.62 15 0.62 15 0.68 15 0.68 15 0.36 15 0.36 15 0.36 15 0.65 15 0.65 15 0.66 15 0.96 15 0.96 15 1.27 15 1.27 15 1.85 15 2.30 15 2.30 15 60Hz Type Model MMU-AP MMU-AP MMU-AP MMU-AP MMU-AP MMU-AP MMU-AP MMU-AP MMU-AP MMU-AP MMU-AP MMU-AP 2-Way Air MMU-AP Discharge MMU-AP Cassette Type MMU-AP MMU-AP MMU-AP MMU-AP MMU-AP MMU-AP 1-Way Air MMU-AP Discharge MMU-AP Cassette Type MMU-AP MMU-AP MMD-AP Concealed Duct Type MMD-AP MMD-AP MMD-AP MMD-AP MMD-AP MMD-AP MMD-AP MMD-AP MMD-AP MMD-AP MMD-AP MMD-AP Concealed Duct MMD-AP High Static MMD-AP Pressure Type MMD-AP MMD-AP MMD-AP MMC-AP MMC-AP Under Ceiling Type MMC-AP MMC-AP MMC-AP MMC-AP MMK-AP Hige Wall Type MMK-AP MMK-AP MMK-AP MMK-AP MMK-AP MML-AP Floor Standing MML-AP Cabinet Type MML-AP MML-AP MML-AP MML-AP MML-AP Floor Standing MML-AP Concealed Type MML-AP MML-AP MML-AP MML-AP MMF-AP Floor Standing Type MMF-AP MMF-AP MMF-AP MMF-AP MMF-AP MMF-AP 4-Way Air Discharge Cassette Type 0091 0121 0151 0181 0241 0271 0301 0361 0481 0561 0071 0091 0121 0151 0181 0241 0271 0301 0071 0091 0121 0151 0181 0241 0071 0091 0121 0151 0181 0241 0271 0301 0361 0481 0561 0181 0241 0271 0361 0481 0721 0961 0151 0181 0241 0271 0361 0481 0071 0091 0121 0151 0181 0241 0071 0091 0121 0151 0181 0241 0071 0091 0121 0151 0181 0241 0151 0181 0241 0271 0361 0481 0561 H H H H H H H H H H WH WH WH WH WH WH WH WH YH YH YH SH SH SH BH BH BH BH BH BH BH BH BH BH BH H H H H H H H H H H H H H H H H H H H H H H H H H BH BH BH BH BH BH H H H H H H H Nominal Voltage (V-Ph-Hz) 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 Voltage Range Min Max 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 198 242 Fan Motor kW FLA 0.060 0.21 0.060 0.21 0.060 0.23 0.060 0.25 0.060 0.29 0.060 0.29 0.060 0.42 0.090 0.70 0.090 0.98 0.090 1.00 0.053 0.38 0.053 0.38 0.053 0.38 0.039 0.44 0.039 0.44 0.053 0.61 0.053 0.61 0.053 0.67 0.022 0.30 0.022 0.30 0.022 0.30 0.034 0.62 0.034 0.62 0.034 0.70 0.120 0.35 0.120 0.35 0.120 0.41 0.120 0.41 0.120 0.52 0.120 0.63 0.120 0.63 0.120 0.73 0.120 1.00 0.120 1.18 0.120 1.18 0.160 1.06 0.160 2.07 0.160 2.07 0.260 2.38 0.260 2.60 0.370 x 3 8.17 0.370 x 3 8.53 0.030 0.35 0.030 0.39 0.040 0.50 0.040 0.50 0.080 0.94 0.080 1.00 0.030 0.37 0.030 0.37 0.030 0.37 0.030 0.39 0.030 0.39 0.030 0.40 0.045 0.29 0.045 0.29 0.045 0.51 0.045 0.51 0.070 0.61 0.070 0.61 0.019 0.31 0.019 0.31 0.019 0.31 0.070 0.53 0.070 0.53 0.070 0.59 0.037 0.77 0.037 0.77 0.063 1.04 0.063 1.04 0.110 1.58 0.160 2.01 0.160 2.01 Power Supply MCA MOCP 0.26 15 0.26 15 0.29 15 0.31 15 0.37 15 0.37 15 0.52 15 0.88 15 1.22 15 1.25 15 0.47 15 0.47 15 0.47 15 0.55 15 0.55 15 0.76 15 0.76 15 0.84 15 0.37 15 0.37 15 0.37 15 0.78 15 0.78 15 0.88 15 0.43 15 0.43 15 0.51 15 0.51 15 0.65 15 0.78 15 0.78 15 0.91 15 1.25 15 1.48 15 1.48 15 1.32 15 2.59 15 2.59 15 2.98 15 3.25 15 10.2 15 10.7 15 0.43 15 0.48 15 0.63 15 0.63 15 1.18 15 1.25 15 0.46 15 0.46 15 0.46 15 0.48 15 0.48 15 0.50 15 0.36 15 0.36 15 0.63 15 0.63 15 0.76 15 0.76 15 0.39 15 0.39 15 0.39 15 0.66 15 0.66 15 0.73 15 0.96 15 0.96 15 1.29 15 1.29 15 1.97 15 2.52 15 2.52 15 10 89 90 Nominal Voltage (V-Ph-Hz) 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 Legend AP1401HT8 AP1601HT8 AP1801HT8 AP2001HT8 AP2201HT8 AP2211HT8 AP2401HT8 AP2411HT8 AP2601HT8 AP2801HT8 AP3001HT8 AP3201HT8 AP3211HT8 AP3401HT8 AP3411HT8 AP3601HT8 AP3611HT8 AP3801HT8 AP4001HT8 AP4201HT8 AP4401HT8 AP4601HT8 AP4801HT8 MCA MOCP ICF RLA 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 Voltage Range Min Max 342 457 342 457 342 457 342 457 342 457 342 457 342 457 342 457 342 457 342 457 342 457 342 457 342 457 342 457 342 457 342 457 342 457 342 457 342 457 342 457 342 457 342 457 342 457 Voltage Range Min Max 342 457 342 457 342 457 342 457 342 457 LRA Unit No.1 RLA LRA _ 5.2 + 5.2 _ 5.2 + 5.2 _ 6.5 + 6.5 _ 6.5 + 6.5 _ 5.2 + 5.2 _ 9.5 + 9.5 _ 5.2 + 5.2 _ 9.5 + 9.5 _ 6.5 + 6.5 _ 6.5 + 6.5 _ 6.5 + 6.5 _ 5.2 + 5.2 _ 9.5 + 9.5 _ 6.5 + 6.5 _ 9.5 + 9.5 _ 6.5 + 6.5 _ 9.5 + 9.5 _ 6.5 + 6.5 _ 6.5 + 6.5 _ 9.5 + 9.5 _ 9.5 + 9.5 _ 9.5 + 9.5 _ 9.5 + 9.5 RLA 4.0 + 4.0 4.6 + 4.6 5.2 + 5.2 6.5 + 6.5 9.5 + 9.5 : Minimum Circuit Amps : Maximum Overcurrent Protection (Amps) : Maximum Instantaneous Current Flow Start : Rated Load Amps AP1401T8 AP1601T8 AP1801T8 AP2001T8 AP2201T8 AP2211T8 AP2401T8 AP2411T8 AP2601T8 AP2801T8 AP3001T8 AP3201T8 AP3211T8 AP3401T8 AP3411T8 AP3601T8 AP3611T8 AP3801T8 AP4001T8 AP4201T8 AP4401T8 AP4601T8 AP4801T8 Heat Pump Nominal Cooling Model Only model Voltage MMY(V-Ph-Hz) MMY- Combination of outdoor unit Heat Pump Cooling Model Only model MMYMMYMAP0501HT8 MAP0501T8 MAP0601HT8 MAP0601T8 MAP0801HT8 MAP0801T8 MAP1001HT8 MAP1001T8 MAP1201HT8 MAP1201T8 Single outdoor unit Compressor LRA FLA kW Unit No.4 RLA LRA _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 5.2 + 5.2 _ _ _ 5.2 + 5.2 _ _ _ 5.2 + 5.2 _ _ _ 5.2 + 5.2 _ 6.5 + 6.5 _ 6.5 + 6.5 _ 6.5 + 6.5 _ 6.5 + 6.5 _ 9.5 + 9.5 : Locked Rotor Amps : Full Load Amps : Fan Motor Rated Output (kW) Compressor Unit No.2 Unit No.3 RLA LRA RLA LRA _ _ _ 4.6 + 4.6 _ _ _ 5.2 + 5.2 _ _ _ 5.2 + 5.2 _ _ _ 6.5 + 6.5 _ _ 5.2 + 5.2 4.6 + 4.6 _ _ _ 6.5 + 6.5 _ _ 5.2 + 5.2 5.2 + 5.2 _ _ _ 9.5 + 9.5 _ _ 5.2 + 5.2 5.2 + 5.2 _ _ 6.5 + 6.5 5.2 + 5.2 _ _ 6.5 + 6.5 6.5 + 6.5 _ _ 5.2 + 5.2 5.2 + 5.2 _ _ 6.5 + 6.5 6.5 + 6.5 _ _ 5.2 + 5.2 5.2 + 5.2 _ _ 9.5 + 9.5 6.5 + 6.5 _ _ 6.5 + 6.5 5.2 + 5.2 _ _ 9.5 + 9.5 9.5 + 9.5 _ _ 6.5 + 9.5 6.5 + 6.5 _ _ 6.5 + 6.5 6.5 + 6.5 _ _ 6.5 + 6.5 6.5 + 6.5 _ _ 9.5 + 9.5 6.5 + 6.5 _ _ 9.5 + 9.5 9.5 + 9.5 _ _ 9.5 + 9.5 9.5 + 9.5 10 kW 0.6 x 2 0.6 x 2 0.6 x 2 0.6 x 2 0.6 x 3 0.6 x 2 0.6 x 3 0.6 x 2 0.6 x 3 0.6 x 3 0.6 x 3 0.6 x 4 0.6 x 3 0.6 x 4 0.6 x 3 0.6 x 4 0.6 x 3 0.6 x 4 0.6 x 4 0.6 x 4 0.6 x 4 0.6 x 4 0.6 x 4 kW 0.60 0.60 0.60 0.60 0.60 o o o MCA MOCP ICF _ 36.5 40 _ 40.0 50 _ 42.5 50 _ 45.0 60 _ 56.5 70 _ 47.0 60 _ 60.0 70 _ 49.0 60 _ 62.5 70 _ 65.0 80 _ 67.5 80 _ 80.0 90 _ 69.5 80 _ 82.5 100 _ 71.5 80 _ 85.0 100 _ 73.5 90 _ 87.5 100 _ 90.0 100 _ 92.0 110 _ 94.0 110 _ 96.0 110 _ 98.0 110 Power Supply MCA MOCP ICF _ 16.5 20 _ 16.5 20 _ 20.0 30 _ 22.5 30 _ 24.5 30 Power Supply NOTE : RLA is based on the following conditions. Indoor temperature : 27 C DB/19 C WB Outdoor temperature : 35 C DB FLA 1.0 + 0.8 1.0 + 1.0 1.0 + 1.1 1.1 + 1.1 1.0 + 1.0 + 0.8 1.1 + 1.1 1.0 + 1.0 + 1.0 1.1 + 1.1 1.1 + 1.1 + 1.0 1.1 + 1.1 + 1.0 1.1 + 1.1 + 1.1 1.0 + 1.0 + 1.0 + 1.0 1.1 + 1.1 + 1.1 1.1 + 1.0 + 1.0 + 1.0 1.1 + 1.1 + 1.1 1.1 + 1.1 + 1.0 + 1.0 1.1 + 1.1 + 1.1 1.1 + 1.1 + 1.1 + 1.0 1.1 + 1.1 + 1.1 + 1.1 1.1 + 1.1 + 1.1 + 1.1 1.1 + 1.1 + 1.1 + 1.1 1.1 + 1.1 + 1.1 + 1.1 1.1 + 1.1 + 1.1 + 1.1 Fan Motor FLA 0.8 0.8 1.0 1.1 1.1 Fan Motor 50Hz 380-3-60 380-3-60 380-3-60 380-3-60 380-3-60 MAP0501HT7 MAP0601HT7 MAP0801HT7 MAP1001HT7 MAP1201HT7 MCA MOCP ICF RLA Voltage Range Min Max 342 418 342 418 342 418 342 418 342 418 342 418 342 418 342 418 342 418 342 418 342 418 342 418 342 418 342 418 342 418 342 418 342 418 342 418 342 418 342 418 342 418 342 418 342 418 LRA FLA kW Unit No.4 RLA LRA _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 5.4 + 5.4 _ _ _ 5.4 + 5.4 _ _ _ 5.4 + 5.4 _ _ _ 5.4 + 5.4 _ 6.9 + 6.9 _ 6.9 + 6.9 _ 6.9 + 6.9 _ 6.9 + 6.9 _ 10.0 + 10.0 : Locked Rotor Amps : Full Load Amps : Fan Motor Rated Output (kW) Unit No.3 RLA LRA _ _ _ _ _ _ _ _ _ 4.8 + 4.8 _ _ _ 5.4 + 5.4 _ _ _ 5.4 + 5.4 _ 5.4 + 5.4 _ 6.9 + 6.9 _ 5.4 + 5.4 _ 6.9 + 6.9 _ 5.4 + 5.4 _ 6.9 + 6.9 _ 5.4 + 5.4 _ 10.0 + 10.0 _ 6.9 + 6.9 _ 6.9 + 6.9 _ 6.9 + 6.9 _ 6.9 + 6.9 _ 10.0 + 10.0 _ 10.0 + 10.0 Compressor Compressor Unit No.2 RLA LRA _ 4.8 + 4.8 _ 5.4 + 5.4 _ 5.4 + 5.4 _ 6.9 + 6.9 _ 5.4 + 5.4 _ 6.9 + 6.9 _ 5.4 + 5.4 _ 10.0 + 10.0 _ 5.4 + 5.4 _ 6.9 + 6.9 _ 6.9 + 6.9 _ 5.4 + 5.4 _ 6.9 + 6.9 _ 5.4 + 5.4 _ 10.0 + 10.0 _ 6.9 + 6.9 _ 10.0 + 10.0 _ 6.9 + 9.9 _ 6.9 + 6.9 _ 6.9 + 6.9 _ 10.0 + 10.0 _ 10.0 + 10.0 _ 10.0 + 10.0 : Minimum Circuit Amps : Maximum Overcurrent Protection (Amps) : Maximum Instantaneous Current Flow Start : Rated Load Amps 380-3-60 380-3-60 380-3-60 380-3-60 380-3-60 380-3-60 380-3-60 380-3-60 380-3-60 380-3-60 380-3-60 380-3-60 380-3-60 380-3-60 380-3-60 380-3-60 380-3-60 380-3-60 380-3-60 380-3-60 380-3-60 380-3-60 380-3-60 AP1401HT7 AP1601HT7 AP1801HT7 AP2001HT7 AP2201HT7 AP2211HT7 AP2401HT7 AP2411HT7 AP2601HT7 AP2801HT7 AP3001HT7 AP3201HT7 AP3211HT7 AP3401HT7 AP3411HT7 AP3601HT7 AP3611HT7 AP3801HT7 AP4001HT7 AP4201HT7 AP4401HT7 AP4601HT7 AP4801HT7 Legend Nominal Voltage (V-Ph-Hz) Heat Pump Model MMY- LRA Unit No.1 RLA LRA _ 5.4 + 5.4 _ 5.4 + 5.2 _ 6.9 + 6.9 _ 6.9 + 6.9 _ 5.4 + 5.4 _ 10.0 + 10.0 _ 5.4 + 5.4 _ 10.0 + 10.0 _ 6.9 + 6.9 _ 6.9 + 6.9 _ 6.9 + 6.9 _ 5.4 + 5.4 _ 10.0 + 10.0 _ 6.9 + 6.9 _ 10.0 + 10.0 _ 6.9 + 6.9 _ 10.0 + 10.0 _ 6.9 + 6.9 _ 6.9 + 6.9 _ 10.0 + 10.0 _ 10.0 + 10.0 _ 10.0 + 10.0 _ 10.0 + 10.0 Voltage Range Min RLA Max 342 418 4.2 + 4.2 342 418 4.8 + 4.8 342 418 5.4 + 5.4 342 418 6.9 + 6.9 342 418 10.0 + 10.0 Combination of outdoor unit Nominal Voltage (V-Ph-Hz) Heat Pump Model MMY- Single outdoor unit 10 91 kW 0.6 x 2 0.6 x 2 0.6 x 2 0.6 x 2 0.6 x 3 0.6 x 2 0.6 x 3 0.6 x 2 0.6 x 3 0.6 x 3 0.6 x 3 0.6 x 4 0.6 x 3 0.6 x 4 0.6 x 3 0.6 x 4 0.6 x 3 0.6 x 4 0.6 x 4 0.6 x 4 0.6 x 4 0.6 x 4 0.6 x 4 kW 0.60 0.60 0.60 0.60 0.60 FLA 0.8 1.0 1.1 1.1 1.0 + 0.8 1.1 1.0 + 1.0 1.1 1.1 + 1.0 1.1 + 1.0 1.1 + 1.1 1.0 + 1.0 + 1.1 + 1.1 1.0 + 1.0 + 1.1 + 1.1 1.1 + 1.0 + 1.1 + 1.1 1.1 + 1.1 + 1.1 + 1.1 + 1.1 + 1.1 + 1.1 + 1.1 + 1.1 + 1.1 + 1.1 + 1.1 + 1.0 1.1 1.1 1.1 1.1 1.1 1.0 1.0 1.0 MCA 36.5 40.0 42.5 45.0 56.5 47.0 60.0 49.0 62.5 65.0 67.5 80.0 69.5 82.5 71.5 85.0 73.5 87.5 90.0 92.0 94.0 96.0 98.0 o o ICF _ _ _ _ _ o MOCP 40 50 50 60 70 60 70 60 70 80 80 90 80 100 80 100 90 100 100 110 110 110 110 ICF _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Power Supply MCA MOCP 16.5 20 16.5 20 20.0 30 22.5 30 24.5 30 Power Supply NOTE : RLA is based on the following conditions. Indoor temperature : 27 C DB/19 C WB Outdoor temperature : 35 C DB 1.0 + 1.0 + 1.0 + 1.1 + 1.0 + 1.1 + 1.0 + 1.1 + 1.1 + 1.1 + 1.1 + 1.0 + 1.1 + 1.1 + 1.1 + 1.1 + 1.1 + 1.1 + 1.1 + 1.1 + 1.1 + 1.1 + 1.1 + Fan Motor FLA 0.8 0.8 1.0 1.1 1.1 Fan Motor 60Hz 10 92 11 Wiring diagram 93 Foreword 94 R(L) S(N) Closed end connector RED WHI Symbol FM TA TC1 TCJ TC2 LM1, LM2 DM FS RY302 PMV Parts name 1 1 2 2 3 3 CN44 1 (BLN) 2 CN66 1 (WHI) 2 BLK 1 1 CN67 (BLK) 2 2 3 3 WHI RED 1 CN304 (GRY) 2 3 BLK : BLACK GRY : GRAY PNK : PINK ORN : ORANGE GRN : GREEN Fan motor Indoor temp sensor Temp sensor Temp sensor Temp sensor Lover motor Drain pump motor Float switch Drain control relay Pulse Motor Valve RED : RED WHI : WHITE YEL : YELLOW BLU : BLUE BRN : BROWN Color identification Power supply Single phase 220-240V 50Hz 220V 60Hz Earth screw Indoor unit Flow selector unit earth screw DM CN68 (BLU) indicates the terminal number. CN60 (WHI) 3. indicates the control P.C. board. Power supply circuit Outdoor unit U1 U2 (Option) Wired remote controller 1 2 1 2 CN1 (WHI) BLK A B WHI U1 U2 1 2 3 4 5 CN81 (BLK) DC20V DC15V DC12V DC7V 1 2 1 2 CN001 (WHI) BLK Adaptor for wireless remote controller WHI WHI BLK 1 2 3 1 2 3 CN41 (BLU) 1 2 1 2 CN40 (BLU) TR CN02 (BLU) 3 3 2 2 1 1 1 1 2 2 1 1 2 2 1 1 2 2 3 3 1 2 PNL 3 1 EXCT 2 CN102 (RED) CN101 (BLK) CN100 (BRN) CN80 (GRN) CN73 (RED) 1 2 3 4 5 MCC-1401 X Y TA 1 Filter input 2 TC1 TC2 TCJ 1 1 2 2 CN104 (YEL) CN20 CN70 (BLU) (WHI) 1 2 CN03 1 2 (RED) Network adaptor P.C. board FS 3 1 CN34 3 2 1 (RED) CN01 1 2 Network adaptor (WHI) 1 2 (Option) 1 2 3 1 2 3 CN309 (YEL) Indoor control P.C. board MCC-1402 1 2 3 4 5 CN33 1 2 3 4 5 (WHI) LM1 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 LM2 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 6 CN82 1 2 3 4 5 6 (BLU) 1 2 3 4 5 6 Fuse T3.15A 250V~ indicates the terminal block, the letter inside (Fandrive) 1 2 CN61 (YEL) T10 1 2 3 4 5 6 Ð ~ CN32 (WHI) + ~ Motor drive circuit PMV 6 4 3 1 2 5 6 4 3 1 2 5 2. A dotted line and broken line indicate the wiring on site. 1. 1 2 3 4 5 CN50 (WHI) P301 Fuse T6.3A 250V~ RY303 RY302 5 4 3 2 1 CN334 1 2 3 4 5 CN333 5 4 3 2 1 (BLU) 1 2 3 4 5 (WHI) FM BLU BLU BLK 60Hz 380V BLK 11 Wiring diagram Foreword 1. Indoor Unit 1-1. 4-way Air Discharge Cassette Type Model: MMU-AP0091H, AP0121H, AP0151H, AP0181H, AP0241H, MMU-AP0271H, AP0301H, AP0361H, AP0481H, AP0561H 11 95 Power supply Single phase 220-240V 50Hz 220V 60Hz Closed end connector Flow selector unit earth screw Indoor unit Earth screw R(L) S(N) RED : RED WHI : WHITE YEL : YELLOW BLU : BLUE BLK : BLACK GRY : GRAY PNK : PINK ORN :ORANGE BRN : BROWN GRN : GREEN Color indication FM 1 (BLK) CN044 1 (BRW) 2 Outdoor unit U1 U2 CN1 (WHI) 1 2 1 2 Remote controller U1 U2 BLK RC YEL BLU L 1 2 3 4 5 RY005 RY006 M CN050 (WHI) H 1 2 3 1 2 3 CN074 (WHI) RY002 UL DP 1 2 1 2 LM FS FS Sub P.C. board MCC-1520 1 2 3 4 5 6 CN02 1 2 3 4 5 6 (YEL) CN075 (WHI) 1 2 3 4 5 6 CN061 (YEL) 1 2 3 4 5 6 CN01 1 2 3 4 5 6 (WHI) PMV 1 2 PNL 3 1 EXCT 2 1 1 2 2 CN080 (GRN) CN073 (RED) CN070 (WHI) CN060 (WHI) Parts name Fan motor Running capacitor Transformer Louver motor Indoor temp sensor Temp sensor Louver control relay Drain control relay Heater control relay Fan motor control relay Float switch Drain pump motor Pulse Motor Valve Option 1 2 3 4 5 6 Fan drive 1 2 CN032 (WHI) 1 1 2 2 3 3 CN100 (BRW) 1 2 3 4 5 1 1 2 2 CN101 (BLK) CN081 (BLK) 1 1 2 2 CN102 (RED) TA Filter TC1 TC2 TCJ 1 1 2 2 CN104 (YEL) 1 2 3 4 5 6 (BLU) 1 2 3 4 5 6 CN082 6 4 3 1 2 5 6 4 3 1 2 5 PMV Indoor control P.C. board 1 2 3 4 5 6 1 2 3 4 5 6 Power supply circuit RY001 1 2 3 (BLU) 1 2 3 (GRN) 1 2 3 (RED) 1 2 3 CN068 1 2 3 CN033 1 2 3 CN030 DM LM Symbol FM Network RC CN01 1 2 adaptor LM (WHI) 1 2 (Option) TR 3 3 TA TR 1 1 2 TC1,TC2,TCJ 2 2 1 1 RY001 CN03 RY002 CN02 (RED) (BLU) MCC-1401 RY004 1. indicates the terminal block, the letter inside RY005~007 indicates the terminal number. FS DM 2. A dotted line and broken line indicate the wiring on site. PMV 3. indicates the control P.C. board. RY007 RED FAN 9 8 7 6 5 4 3 2 1 CN083(WHI) 9 8 7 6 5 4 3 2 1 A B X Y 1 2 3 1 2 3 CN040 CN041 (BLU) (BLU) 1 2 1 2 Line Filter TR Fuse T5.0A RY004 P301 1 1 2 2 CN067 250V~ (BLK) 3 3 1 1 2 2 3 3 CN066 1 (WHI) 2 CN039 (YEL) 3 CN304 (GRY) 2 9 WHI 1 2 RED 3 4 5 6 7 BLU BLU ORN 96 BLK 11 BLK 1 2 3 4 5 6 7 1-2. 2-way Air Discharge Cassette Type Model: MMU-AP0071WH, AP0091WH, AP0121WH, AP0151WH, AP0181WH, MMU-AP0241WH, AP0271WH, AP0301WH, AP0481WH RED : RED WHI : WHITE YEL : YELLOW BLU : BLUE BLK : BLACK GRY : GRAY PNK : PINK ORN :ORANGE BRN : BROWN GRN : GREEN Color indication WHI RED Power supply Single phase 220-240V 50Hz 220V 60Hz WHI 1 1 3 CN304 (GRY) 2 1 Heater BLU RY004 Line Filter TR BLU 1 2 1 2 Outdoor unit U1 U2 1 2 1 2 CN1 (WHI) AI-NET central control terminal A B X Y 1 2 3 1 3 Remote controller U1 U2 BLU 1 2 1 2 YEL BLU ORN BLK RED L CN03 (RED) 1 1 2 2 3 2 1 CN02 3 2 1 (BLU) Network adaptor P.C. board Network CN01 1 2 adaptor (WHI) 1 2 (Option) 1 2 3 4 5 RY005 RY006 M CN050 (WHI) H MCC-1401 RY007 DP 2 1 2 1 LM LM 2 1 2 1 FS FS TR 1 2 3 4 5 6 CN01 1 2 3 4 5 6 (WHI) Sub P.C. board MCC-1520 1 2 3 4 5 6 CN02 1 2 3 4 5 6 (YEL) 1 2 3 4 5 6 1 2 3 4 5 6 CN075 (WHI) 1 2 3 4 5 6 CN061 (YEL) 3. indicates the control P.C. board. 2. A dotted line and broken line indicate the wiring on site. indicates the terminal number. PMV 1 EXCT 2 1 1 Filter 2 2 CN080 (GRN) CN073 (RED) CN070 (WHI) CN060 (WHI) Symbol FM RC TR LM TA TC1,TCJ RY001 RY002 RY004 RY005~007 FS DM PMV Parts name Fan motor Running capacitor Power transformer Louver motor Indoor temp sensor Temp sensor Flap motor control relay Drain pump control relay Heater control relay Fan motor control relay Float switch Drain pump motor Pulse Motor Valve Option 1 2 3 4 5 6 Fan drive 1 2 CN032 (WHI) 1 2 PNL 3 1 2 3 4 5 1 1 2 2 3 3 CN100 (BRW) CN081 (BLK) 1 2 CN101 (BLK) TC1 TCJ 1 1 2 2 CN102 (RED) TA 1 1 2 2 CN104 (YEL) 1 2 3 4 5 6 (BLU) 1 2 3 4 5 6 CN082 6 4 3 1 2 5 6 4 3 1 2 5 PMV Indoor control P.C. board indicates the terminal block, the letter inside 1 2 3 1 2 3 Power supply circuit RY001 1 2 3 (BLU) 1 2 3 (GRN) 1 2 3 (RED) 1 2 3 CN068 1 2 3 CN033 1 2 3 CN030 CN074 (WHI) 1. DM 1 2 3 1 2 3 RY002 UL FAN 9 8 7 6 5 4 3 2 1 CN083(WHI) 9 8 7 6 5 4 3 2 1 CN044 CN040 CN041 (BRW) (BLU) (BLU) 1 1 2 2 CN067 Fuse (BLK) T5.0A 3 3 CN066 1 (WHI) 2 AC IN 3 3 CN309 (YEL) 2 2 Closed end connector Flow selector unit earth screw Indoor unit Earth screw R(L) S(N) RED CN301 (BLK) BLU RC BLK FM BLU 1 2 3 4 5 6 BLK 1 2 3 4 5 6 1-3. 1-way Air Discharge Cassette Type (Compact type) Model: MMU-AP0071YH, AP0091YH, AP0121YH 11 97 TR EMG CN066 (WHI) 1 2 CN044 (BRW) 1 2 3 3 3 3 AC IN 1 1 1 1 3 1 P301 BLK 3 4 5 6 Power supply single phase 220-240V 50Hz 220V 60Hz 1 2 1 2 CN040 (BLU) (BLK) CN067 U1 U2 1 2 1 2 Outdoor unit U1 U2 Closed-end connector FUSE (YEL) CN309 (GRY) CN304 B 1 2 1 2 CN1 A 3 3 2 1 1 H L 3 3 3 3 3. 1 1 1 2 1 2 LM 1 2 3 4 5 6 CN02 1 2 3 4 5 6 (YEL) the letter inside indicates the terminal number. indicates the control P.C. board. the wiring on site. TR 1 2 3 4 5 6 CN01 1 2 3 4 5 6 (WHI) Sub P.C. board MCC-1520 3 CN030 3 (RED) CN061 (YEL) 1 2 CN070 (WHI) OPTION FAN DRIVE TC1 RED : RED WHI : WHITE YEL : YELLOW BLU : BLUE BLK : BLACK GRY : GRAY PNK : PINK ORN :ORANGE BRN : BROWN GRN : GREEN Color indication Parts name Fan motor Running capacitor Transformer Lover motor Indoor temp sensor Temp sensor Louver control relay Drain control relay Fan motor control relay Float switch Drain pump motor Pulse motor valve 1 2 3 4 5 6 CN060 (WHI) 1 2 3 4 5 1 EXCT 2 CN073 (RED) CN081 (BLK) 1 2 PNL 3 CN080 (GRN) FILTER 1 1 2 3 3 CN100 (BRW) TC2 TCJ TA 1 1 2 2 1 1 2 2 1 1 2 2 CN101 (BLK) CN102 (RED) CN104 (YEL) PMV 1 2 3 4 5 6 CN082 1 2 3 4 5 6 (BLU) 6 4 3 1 2 5 6 4 3 1 2 5 PMV 1 2 CN032 (WHI) Symbol FM RC TR LM TA TC1,TC2,TCJ RY001 RY002 RY005~007 FS DM PMV 1 2 3 4 5 6 CN075 (WHI) 1 2 3 4 5 6 1 2 3 4 5 6 1 1 FS FS Control P.C. board for Indoor unit MCC-1403 3 CN033 3 (GRN) LM Power supply circuit RY001 DM Indicates the terminal bolock, MCC-1401 DM 2. A dotted line and broken line indicate 1. X Y 1 2 1 2 CN03(RED) CN02 (BLU) CN074 1 (WHI) 1 RY002 CN068 1 (BLU) 1 Network Adapter (Option) UL CN01(WHI) 1 2 1 2 1 2 3 4 5 CN050 (WHI) RY005 RY006 M Remote Controller 1 2 3 RC 1 3 RY007 RED BLK ORN BLU YEL FAN 7 5 3 1 CN083 9 (WHI) 9 7 5 3 1 CN041 (BLU) RY004 T5.0A 250V~ Line Filter Flow selector unit earth screw RC R(L) S(N) Indoor unit earth screw FM BLU 1 BLU 98 BLK 11 BLK 1 2 3 4 5 6 Model: MMU-AP0151SH, AP0181SH, AP0241SH R(L) S(N) Outdoor unit U1 U2 1 1 1 2 2 3 3 1 1 CN44 1 (BRW) 2 Ð ~ Adaputor for wired remote controller Wired remote controller CN001 (WHI) BLK CN50 (WHI) 5 5 FM X Y 1 2 CN03 1 2 (RED) Network adaptor P.C. board (Signal output) indicates the terminal number. indicates the terminal block, the letter inside 1 2 3 4 5 6 1 2 CN60 (WHI) (Fan drive) CN32 (WHI) 3. indicates the control P.C. board. FS Symbol FM TA TC1,TC2,TCJ DM FS RY302 PMV Parts name Fan motor Indoor temp sensor Indoor temp sensor Drain pump motor Float switch Drain pump control relay Pulse Motor Valve BLK : BLACK GRY : GRAY PNK : PINK ORN : ORANGE GRN : GREEN Color identification 1 2 3 4 5 1 2 1 EXCT 2 CN73 (RED) TC1 TC2 CN80 (GRN) CN20 CN70 (BLU) (WHI) TA TCJ 1 2 PNL 3 1 1 2 2 CN101 (BLK) 1 1 2 2 3 3 1 1 2 2 CN102 (RED) CN100 (BRN) 1 1 2 2 CN104 (YEL) 3 1 CN34 3 2 1 (RED) RED : RED WHI : WHITE YEL : YELLOW BLU : BLUE BRN : BROWN 1 2 3 4 5 CN81 (BLK) 2. A dotted line and broken line indicate the wiring on site. 1. Network CN01 1 2 adaptor (WHI) 1 2 (Option) 3 3 2 2 1 1 CN61 (YEL) Power supply circuit DC20V DC15V DC12V DC7V CN33 1 2 3 4 5 (WHI) Indoor control P.C. board 1 2 3 4 5 6 CN82 1 2 3 4 5 6 (BLU) 6 4 3 1 2 5 6 4 3 1 2 5 PMV T10 1 2 3 4 5 6 250V~ Fuse T3.15A 1 2 3 4 5 CN02 (BLU) TR 1 2 3 1 2 3 + CN309 (YEL) 3 3 1 2 3 1 2 3 Motor drive circuit CN333 1 (WHI) 1 1 1 ~ 1 2 1 2 WHI WHI BLK 1 2 3 1 2 3 CN41 (BLU) CN334 (WHI) 1 2 1 2 CN40 (BLU) P301 250V~ Fuse T6.3A RY302 1 2 1 2 CN1 (WHI) BLK A B WHI U1 U2 BLK 3 3 CN66 1 (WHI) 2 WHI CN67 (BLK) 2 2 RED 3 CN304 (GRY) 2 Flow selector unit earth screw Closed end connector WHI Reactor WHI Indoor unit power supply Single phase 220-240V 50Hz 220V 60Hz Earth screw Indoor unit RED 1 3 1 2 2 DM 5 4 2 1 5 4 3 2 1 BLU BLU BLK CN68 (BLU) BLK 5 5 4 4 1-4. Concealed Duct Standard Type Model: MMD-AP0071BH, AP0091BH, AP0121BH, AP0151BH, AP0181BH, AP0241BH MMD-AP0271BH, AP0301BH, AP0361BH, AP0481BH, AP0561BH 11 99 Indoor unit Earth screw Closed end connector WHI RED S(N) F CN067 (BLK) RY007 1 2 1 2 4 43F1 3 5 43F1 1 2 3 4 1 2 3 4 GRY FM Remote controller 1 2 1 2 CN1 (WHI) A B 1 2 3 1 3 RC U1 U2 OC U1 U2 EMG 1 2 CN044 CN040 CN041 (BRW) (BLU) (BLU) Outdoor unit YEL Closed end connector Fuse T5.0A CN066 (WHI) RED RED 6 Flow selector unit earth screw TR 1 2 1 1 2 2 3 3 RED RC L 3 3 2 1 1 F4 F3 F2 X Y F1 WHI MCC-1401 DP LM CN074 (WHI) RY001 1 2 3 1 2 3 1 2 1 2 CN075 CN061 (WHI) (YEL) CN032 (WHI) CN060 (WHI) CN082 (BLU) TR 1 2 3 4 5 6 CN01 1 2 3 4 5 6 (WHI) Sub P.C. board MCC-1520 1 2 3 4 5 6 CN02 1 2 3 4 5 6 (YEL) Motor over heating protection switch WHI GRY RED BLK Wired for MMD-AP0481 only (BRN Wire) 49F ORN BRN BLU 5 2 1 3 4 6 Symbol FM RC TR TA TC1,TC2,TCJ RY005~007 RY001 RY002 PMV F 43F1 Sold DM separately FS 6 5 4 3 2 1 6 5 4 3 2 1 1 Filter 2 CN070 (WHI) 1 2 3 4 5 1 EXCT 2 CN073 (RED) CN081 (BLK) 1 2 PNL 3 CN080 (GRN) 1 2 3 CN100 1 2 3 (BRN) TC1 1 2 3 4 5 6 1 2 3 4 5 6 1 2 1 2 3 4 5 6 Option 1 2 3 4 5 6 T10 Fan drive Power supply circuit 1 2 1 2 TC2 CN104 CN102 CN101 (YEL) (RED) (BLK) 1 2 1 2 TCJ Indoor control P.C. board FS CN030 (RED) 1 2 3 1 2 3 TA 1. indicates the terminal block, the letter inside indicates the terminal number. 2. A dotted line and broken line indicate the wiring on site. 3. indicates the control P.C. board. 4. When installing a drain pump, Remove CN030 connector and connect float switch. 5. A part is connected to the terminal block. When a change is required due to the outside static pressure at site, check the terminal No. and lead colour of the fan motor in the below diagram and then change the lead wire as indicated by the arrow mark ( ), 6. Pay attention when changing static pressure because the outside static pressure of H tap in 50 or 60Hz. Network adaptor (Option) 1 2 CN03 1 2 (RED) CN01 1 2 (WHI) 1 2 DP 1 2 3 (BLU) 1 2 3 (GRN) 1 2 3 CN068 1 2 3 CN033 RY002 UL 1 2 3 4 5 CN050 (WHI) RY005 RY006 M CN02 (BLU) H FAN 9 8 7 6 4 2 CN083(WHI) 9 8 7 6 5 4 3 2 1 7 RY004 P301 43F1 1 1 CN309 2 2 (YEL) 3 3 3 CN304 (GRY) 2 1 (BLK) T10A,250V~ Power supply Single phase 220-240V 50Hz 220V 60Hz R(L) RED RED : RED WHI : WHITE YEL : YELLOW BLU : BLUE BLK : BLACK GRY : GRAY PNK : PINK ORN :ORANGE BRN : BROWN GRN : GREEN 8 BLU WHI ORN Color indication WHI RED GRY WHI RED BLK 100 (Option) 11 BRN Spark killer PMV Parts name Fan motor Running capacitor Transformer Indoor temp sensor Temp sensor Fan motor control relay Flap motor control relay Drain control relay Pulse Motor Valve Fuse Fan motor control relay Drain pump motor Float switch 5 2 1 3 4 6 1-5. Concealed Duct High Static Pressure Type Model: MMD-AP0181H, AP0241H, AP0271H, AP0361H, AP0481H Symbol FM RC TR TA TC1,TC2,TC3 RY005~007 RY001 RY002 PMV F1~3 43F1,43F2 DM FS R(L) S(N) WHI Power supply single phase 220-240V 50Hz 220V 60Hz Indoor unit earth screw RED WHI RED Parts name Fan motor Running capacitor Transformer Indoor temp sensor Temp sensor Fan motor control relay Louver control relay Drain control relay Pulse motor valve Fuse for fan motor Fan motor control relay Drain pump motor Float switch RED : RED WHI : WHITE YEL : YELLOW BLU : BLUE BLK : BLACK GRY : GRAY PNK : PINK ORN :ORANGE BRN : BROWN GRN : GREEN Closed-end connector Motor over heating protection switch 49F Color indication WHI GRY RED WHI RED 7 WHI 8 AC IN S.K F3 F2 1 2 3 3 1 1 F1 WHI RED 3 3 1 1 3 1 P301 (BLK) 43F1 3 FAN3 1 2 3 4 4P 1 2 3 4 (RED) 5 RED FM3 RC F1 ORW F2 F3 X Y F4 CN03(RED) 1 2 1 2 RY001 DP 3 CN068 3 (BLU) 1 CN074 1 (WHI) 1 4 6 43F2 MCC-1401 FAN2 1 2 3 4 4P 1 2 3 4 (BLU) 3 3 FM2 F1 ORW RC LM CN033 3 (GRN) Network Adapter (Option) CN01(WHI) CN02 (BLU) 1 2 1 2 1 2 3 4 5 CN050 (WHI) 3 3 2 1 1 1 1 RY002 UL 1 1 Indicates the terminal bolock, Letter on the inside indicates the terminal number. 2. A dotted line and broken line indicate the wiring on site. 3. indicate the control p.c. board. 4. When fitting a drain pump remove CN030 connector and connect float switch. 1. Closed-end connector 3 5 43F2 Outdoor unit U1 U2 B L RY005 1 2 1 2 CN1 Remote Controller RED A T10.0A, 250V~ 5 M H 3 3 RY006 5 5 7 7 1 2 1 2 3 1 2 CO 1 3 RC CN041 (BLU) RY007 U1 U2 Line Filter 1 2 EMG TR CN044 CN040 (BRW) (BLU) CN066 (WHI) CN067 (BLK) T5.0A 250V~ FUSE (YEL) CN309 (GRY) CN304 RY004 T10.0A, 250V~ T10.0A, 250V~ RED RED RED Sold separately WHI BLK YEL BLU ORN 8 S.K WHI 8 BLU 43F2 BLU 43F1 BLK Fan motor inside wiring diagram BLK WHI RED GRY WHI RED GRY YEL FAN CN083 9 (WHI) 9 YEL Spark Killer BLU 7 ORN WHI RED GRY WHI RED GRY 7 YEL 6 1 1 3 3 F2 F3 43F1 PMV FAN1 1 2 3 4 4P 1 2 3 4 (WHI) FM1 F1 ORW RC F2 F3 F4 5. A Position is connected to the terminal block when there is a change to static pressure. change the lead wire of arrow position after checking the terminal number as per figure and the lead wire's checking fan motor. 6. When setting to the high tap, take care as the static pressures are different at50Hz and 60Hz. F4 4 5 2 1 3 4 6 Terminal Fan motor Static pressure Note No. wiring Pa (mmAg) F1 YEL 69(7) F2 BLU 137(14) Setting from factory F3 ORN 196(20) FAN DRIVE 6 OPTION 1 2 CN060 (WHI) 1 2 3 4 5 6 CN032 (WHI) 6 5 4 3 2 1 CN082 (BLU) 5 2 1 3 4 6 1 2 3 4 5 CN081 (BLK) 6 5 4 3 2 1 1 FILTER 2 CN070 (WHI) Control P.C. board for Indoor unit MCC-1403 1 EXCT 2 1 2 PNL 3 CN073 (RED) CN100 (BRW) CN080 (GRN) 1 3 1 2 3 CN061 (YEL) 1 2 3 4 5 6 CN01 1 2 3 4 5 6 (YEL) TR 1 2 1 2 TC1 1 2 3 4 5 6 1 2 3 4 5 6 CN02 1 2 3 4 5 6 (YEL) Sub P.C. board MCC-1520 1 2 1 2 1 2 1 2 TC2 CN104 CN102 CN101 (YEL) (RED) (BLK) TCJ TA Control P.C. board for Indoor unit MCC-1403 CN030 (RED) FS CN075 (WHI) 1 2 3 4 5 6 1 2 3 4 5 6 Power supply circuit BLU RED ORN WHI RED GRY WHI RED GRY DM YEL (Option) BLU RED ORN RED Model: MMD-AP0721H, AP0961H 11 101 102 RED WHI Flow selector unit earth screw 3 CN304 1 (GRY) 2 1 1 2 2 3 3 CN41 (BLU) CN40 (BLU) CN66 (WHI) Fuse T6.3A 250V~ P301 RY303 RY302 BLK Adpter for wireless remote controller CN001 (WHI) BLK WHI BLK 1 2 3 4 5 Wired remote controller WHI Ð + CN50 (WHI) 1 2 1 2 CN1 (WHI) 1 2 3 1 2 3 CN309 (YEL) ~ ~ indicates the terminal number. indicates the terminal block, the letter inside X Y 1 2 CN03 1 2 (RED) Network adaptor P.C. board Option 1 2 3 4 5 6 CN60 (WHI) DC20V DC15V DC12V DC7V 3. indicates the control P.C. board. CN81 (BLK) CN70 (WHI) CN73 (RED) CN80 (GRN) CN100 (BRW) TA 1 FILTER 2 BLK : BLACK GRY : GRAY PNK : PINK ORN : ORANGE GRN : GREEN Parts name Fan motor Indoor temp sensor Temp sensor Louver motor Drain control relay Drain pump motor Float switch RED : RED WHI : WHITE YEL : YELLOW BLU : BLUE BRN : BROWN TC1 TC2 TCJ 1 EXCT 2 1 2 PNL 3 1 1 2 2 3 3 1 1 2 2 1 1 2 2 CN102 (RED) CN101 (BLK) 1 1 2 2 CN104 (YEL) Color identification GRL FS 1 3 CN34 1 2 3 (RED) 1 2 3 4 5 CN20 (BLU) Symbol FM TA TC1,TC2,TCJ LM RY302 DM Sold separately FS 1 2 3 4 5 2. A dotted line and broken line indicate the wiring on site. 1. 3 3 2 2 1 1 Network CN01 1 2 adaptor (WHI) 1 2 (Option) CN02 (BLU) TR 1 2 Fandrive CN32 (WHI) Power supply circuit T10 CN61 (YEL) Fuse T3.15A Indoor control P.C. board 1 2 3 4 5 CN33 1 2 3 4 5 (WHI) 1 2 3 4 5 6 CN82 1 2 3 4 5 6 (BLU) LM 1 2 3 4 5 1 2 3 4 5 PMV 6 4 3 1 2 5 6 4 3 1 2 5 1 2 3 4 5 6 Motor drive circuit 5 4 1 CN334 1 2 3 4 5 CN333 5 4 3 2 1 (WHI) 1 2 3 4 5 (WHI) 1 2 1 2 WHI U1 U2 A B 1 1 2 BLK 3 3 BLK 2 2 BLU 1 1 BLU 1 2 BLK 1 1 CN67 (BLK) 2 2 3 3 Outdoor unit U1 U2 Closed end terminal RED WHI Power supply single phase 200-240V 50Hz 200V 60Hz R(L) S(N) Earth screw Indoor unit DM CN68 (BLU) 11 FM 1-6. Under Ceiling Type Model: MMC-AP0151H, AP0181H, AP0241H, AP0271H, AP0361H, AP0481H RED : RED WHI : WHITE YEL : YELLOW BLU : BLUE BLK : BLACK GRY : GRAY PNK : PINK ORN :ORANGE BRN : BROWN GRN : GREEN Color indication Earth screw Indoor unit Power supply single phase 220-240V 50Hz 220V 60Hz R(L) S(N) Outdoor unit X GRY 1 2 1 2 CN001 (WHI) BLK Wired remote Adapter for controller wireless remote controller 1 2 1 2 CN1 (WHI) Y GRY BLK BLK BLK WHI 1 2 3 1 3 1 2 1 2 BLU BLU CN41 (BLU) CN40 (BLU) T6.3A 250V~ FUSE RY303 RY302 BLK WHI B CN66 (WHI) 1 2 P301 BLK 3 3 CN67 (BLK) 1 1 3 3 CN304 (GRY) A WHI U1 U2 U1 U2 RED Closed-end connector WHI Flow selector unit earth screw WHI RED LM 3 1 1 1 CN68 (BLU) 1 1 CN334 5 4 2 1 (WHI) 5 4 3 2 1 5 5 1 2 1 2 CN03(RED) CN01(WHI) CN02 (BLU) 1 2 1 2 1 2 3 4 5 CN50 (WHI) PMV 3 3 1 1 2 2 TC2 Option 1 2 3 4 5 CN81 (BLK) 1 2 3 4 5 CN20 (BLU) Symbol FM TA TC1,TC2,TCJ PMV LM RY303 1 2 CN70 (WHI) Parts name Fan motor Indoor temp sensor Temp sensor Pulse motor valve Lover motor Louver control relay indicates the control P.C. board. the wiring on site. 2. A dotted line and broken line indicate 3. 1 2 EXCT CN73 (RED) the letter inside indicates the terminal number. 1 2 3 1 2 CN080 (GRN) CN100 (BRW) CN103 (GRN) 1 3 1 2 3 TC1 Indicates the terminal bolock, 1 2 3 4 5 6 1 2 Fandrive 1 2 3 4 5 6 1. 1 1 2 2 TCJ CN104 CN102 CN101 (YEL) (RED) (BLK) 1 1 2 2 TA Control P.C. board for Indoor unit MCC-1402 CN32 (WHI) CN60 (WHI) DC20V DC15V DC12V DC7V CN34 (RED) 1 1 CN61 (YEL) T3.15A 250V~ Power supply circuit CN33 (WHI) CN82 (BLU) FUSE 1 2 3 4 5 1 2 3 4 5 6 1 2 3 4 5 6 6 4 3 1 2 5 6 4 3 1 2 5 Network Adapter (Option) MCC-1401 3 3 2 1 1 TR 3 CN309 3 (YEL) 3 3 1 2 3 1 2 3 FM Motor drive circuit CN333 1 (WHI) 1 1 1 5 5 4 4 1-7. High Wall Type Model: MMK-AP0071H, AP0091H, AP0121H, AP0151H, AP0181H, AP0241H 11 103 TR CN066 (WHI) 1 1 2 2 RED Closed-end connector WHI Power supply single phase 220-240V 50Hz 220V 60Hz R(L) S(N) Indoor unit earth screw 3 3 1 1 WHI CN067 (BLK) RED 3 3 1 1 3 3 1 1 P301 (BLK) FUSE (YEL) CN309 (GRY) CN304 1 2 1 2 CN040 (BLU) Outdoor unit U1 U2 U1 U2 B 1 2 1 2 CN1 A 3 3 2 1 1 L X Y 1 2 1 2 CN03(RED) CN02 (BLU) CN074 1 (WHI) 1 RY002 CN068 (BLU) 1 3 3 3 LM 1 1 2 3 4 5 6 1 2 3 4 5 6 Sub P.C. board MCC-1520 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 PMV 1 2 3 4 5 6 CN082 1 2 3 4 5 6 (BLU) TR CN01 (WHI) CN02 (YEL) 1 2 3 4 5 6 T10 CN061 (YEL) 1 EXCT 2 1 2 1 2 3 4 5 CN073 (RED) CN070 (WHI) CN081 (BLK) OPTION Symbol FM RC TR TA TC1,TC2,TCJ RY001 RY002 RY004 RY005~007 PMV 1 2 3 4 5 6 1 2 CN060 (WHI) 1 2 PNL 3 CN080 (GRN) RED : RED WHI : WHITE YEL : YELLOW BLU : BLUE BLK : BLACK GRY : GRAY PNK : PINK ORN :ORANGE BRN : BROWN GRN : GREEN Color indication Parts name Fan motor Running capacitor Transformer Indoor temp sensor Temp sensor Louver control relay Drain control relay Heater control relay Fan motor control relay Pulse motor valve FILTER TC1 1 1 2 2 CN100 (BRN) TC2 TCJ TA 1 1 2 2 1 1 2 2 1 1 2 2 CN101 (BLK) CN102 (RED) CN104 (YEL) FS 1 3 CN030 1 2 3 (RED) FAN DRIVE CN032 (WHI) Control P.C. board for Indoor unit MCC-1403 CN075 (WHI) CN033 3 (GRN) Power supply circuit RY001 DP 6 4 3 1 2 5 6 4 3 1 2 5 PMV indicates the terminal block. the letter inside indicates the terminal number. 2. A dotted line and broken line indicate the wiring on site. 3. Indicates the control p.c. board. 1. MCC-1401 Network Adapter (Option) UL CN01(WHI) 1 2 1 2 1 2 3 4 5 CN050 (WHI) RY005 RY006 M Remote Controller 1 2 3 RC 1 3 RY007 H RED BLK ORN BLU YEL FAN 7 5 3 1 CN083 9 (WHI) 9 7 5 3 1 CN041 (BLU) RY004 T5.0A 250V~ Flow selector unit earth screw Line Filter AC IN RC 2 3 4 5 6 BLU 2 3 4 5 6 BLU 104 BLK 11 BLK FM 1-8. Floor Standing Cabinet Type Model: MML-AP0071H, AP0091H, AP0121H, AP0151H, AP0181H, AP0241H WHI A B Outdoor unit 1 2 1 2 CN1 Remote Controller U1 U2 1 2 1 2 RC X Y MCC-1401 CN03(RED) CN02 (BLU) 1 1 2 2 CN03 (RED) CN041 (BLU) 1 2 3 1 3 1 2 1 2 RY007 H L UL CN074 1 (WHI) 1 RY002 RED : RED WHI : WHITE YEL : YELLOW BLU : BLUE BLK : BLACK GRY : GRAY PNK : PINK ORN :ORANGE BRN : BROWN GRN : GREEN Color indication 1 2 3 4 5 CN050 (WHI) RY005 RY006 M RED BLK ORN BLU YEL FAN 7 5 3 1 CN068 1 CN083 9 (WHI) 9 (BLU) 1 7 5 3 1 2 4 5 6 3 CN040 (BLU) CN044 (BRW) CN066 (WHI) (BLK) CN067 T5.0A 250V~ FUSE (YEL) CN309 (GRY) CN304 RY004 RC 2 4 5 6 3 indicates the terminal block. the letter inside indicates the terminal number. 2. A dotted line and broken line indicate the wiring on site. 3. Indicates the control p.c. board. 1. 3 3 2 1 1 EMG 1 2 1 2 3 3 3 3 AC IN 1 1 1 1 3 1 RED FM R301 (BLK) GRN Network adapter (Option) CN01(WHI) 1 2 1 2 RED BLK ORN BLU YEL FAN 7 5 3 1 CN083 9 (WHI) 9 7 5 3 1 WHI RED For AP0071BH,AP0091BH,AP0121BH FM 1 3 2 4 5 6 WHI GRN U1 U2 TR Closed-end connector Flow selector unit earth screw RED R(L) S(N) RED Power supply single phase 220-240V 50Hz 220V 60Hz Indoor unit earth screw WHI 1 3 2 4 5 6 3 3 3 3 CN082 (BLU) CN104 (YEL) CN030 (RED) 1 2 3 4 5 6 Symbol FM RC TR TA TC1,TC2,TCJ RY001 RY002 RY004 RY005~007 PMV TR 1 2 3 4 5 6 CN01 1 2 3 4 5 6 (WHI) Sub P.C. board MCC-1520 1 2 3 4 5 6 CN02 1 2 3 4 5 6 (YEL) 1 2 3 4 5 6 1 2 3 4 5 6 CN061 CN075 (YEL) (WHI) CN081 (BLK) OPTION Parts name Fan motor Running capacitor Transformer Indoor temp sensor Temp sensor Louver control relay Drain control relay Heater control relay Fan motor control relay Pulse motor valve 1 2 3 4 5 6 1 2 CN060 (WHI) FAN DRIVE CN032 (WHI) 1 2 3 4 5 FILTER 1 2 CN070 (WHI) TC2 TCJ TA 1 EXCT 2 1 2 PNL 3 1 1 2 3 3 1 1 2 2 1 1 2 2 1 1 2 2 CN073 (RED) CN080 (GRN) CN100 (BRW) CN101 (BLK) CN102 (RED) 1 2 3 4 5 6 1 2 3 4 5 6 PMV 1 3 1 2 3 Control P.C. board for undoor unit MCC-1403 3 CN033 3 (GRN) Power supply circuit RY001 1 1 6 4 3 1 2 5 6 4 3 1 2 5 PMV TC1 1-9. Floor Standing Concealed Type Model: MML-AP0071BH, AP0091BH, AP0121BH, AP0151BH, AP0181BH, AP0241BH 11 105 RED WHI Closed-end connector Power supply single phase 220-240V 50Hz 220V 60Hz R(L) S(N) Indoor unit earth screw 1 1 3 1 P301 (BLK) FUSE (YEL) CN309 1 2 1 2 CN040 (BLU) (BLK) CN067 Outdoor unit U1 U2 U1 U2 1 2 1 2 B 1 2 1 2 CN1 A 3 3 2 1 1 H MCC-1401 3 3 3 3. 1 1 LM 2 1 2 1 1 2 3 4 5 6 CN02 (YEL) 1 2 3 4 5 6 the letter inside indicates the terminal number. Indicates the control p.c. board. the wiring on site. TR 1 2 3 4 5 6 CN01 1 2 3 4 5 6 (WHI) Sub P.C. board MCC-1520 CN061 (YEL) . CN081 (BLK) 1 2 3 4 5 6 OPTION 1 2 CN060 (WHI) FAN DRIVE CN032 (WHI) TC1 RED : RED WHI : WHITE YEL : YELLOW BLU : BLUE BLK : BLACK GRY : GRAY PNK : PINK ORN :ORANGE BRN : BROWN GRN : GREEN Color indication Parts name Fan motor Running capacitor Transformer Lover motor Indoor temp sensor Temp sensor Louver control relay Drain control relay Fan motor control relay Pulse motor valve FILTER 1 2 CN070 (WHI) 1 2 3 4 5 1 EXCT 2 CN073 (RED) TC2 TCJ TA 1 2 PNL 3 3 3 1 1 1 1 2 2 1 1 2 2 1 1 2 2 CN080 (GRN) CN100 (BRW) CN101 (BLK) CN102 (RED) CN104 (YEL) PMV 1 2 3 4 5 6 CN082 1 2 3 4 5 6 (BLU) 6 4 3 1 2 5 6 4 3 1 2 5 PMV Symbol FM RC TR LM TA TC1,TC2,TCJ RY001 RY002 RY005~007 PMV 1 2 3 4 5 6 CN075 (WHI) 1 2 3 4 5 6 1 2 3 4 5 6 1 3 CN030 1 2 3 (RED) FS Control P.C. board for Indoor unit MCC-1403 3 CN033 3 (GRN) LM Power supply circuit RY001 DP Indicates the terminal bolock, letter. X Y 1 2 1 2 CN03(RED) CN02 (BLU) CN074 1 (WHI) 1 RY002 Network Adapter (Option) CN01(WHI) 1 2 1 2 1 2 3 4 5 CN050 (WHI) UL CN068 (BLU) 1 2. A dotted line and broken line indicate 1. L RY005 RY006 M Remote Controller 1 2 3 RC 1 3 RY007 RED BLK ORN BLU YEL FAN 7 5 3 1 CN083 9 (WHI) 9 7 5 3 1 CN041 (BLU) RY004 (GRY) CN304 RC T5.0A 250V~ Line Filter TR EMG CN066 (WHI) 1 2 CN044 (BRW) 1 2 3 3 3 3 AC IN 1 1 BRW Flow selector unit earth screw FM 3 4 5 6 7 BLU 3 4 5 6 7 8 BLU 106 BLK 11 BLK 1 1 1-10. Floor Standing Type Model: MMF-AP0151H, AP0181H, AP0241H, AP0271H, AP0361H, AP0481H, AP0561H Symbol SV42 BLU BLU 1 1 3 3 BLU 5 5 7 7 3 3 T Heater 2 Heater 1 CN315(BLU) 1 1 BRW 3 3 CN316(WHI) 1 1 BRW CN310(WHI) 4 3 SV51 BLU 2 2 BLU 1 1 CN312(WHI) BLU 3 3 SV2 BLU 1 1 CN324(RED)BLU 3 3 SV3A BLU 1 1 CN313(YEL) BLU 3 3 SV3B BLU 1 1 CN314(BLK) BLU 3 3 SV3C BLU 1 1 SV41 CN311(BLU) BLU CM1, CM2 PMV1, PMV2 SV2, SV41, SV42, SV51, SV3A, SV3B, SV3C, SV3D, SV3E 4WV1 COMP1, COMP2 TS1 TD1, TD2 TE1 TO TK1, TK2, TK3, TK4 TL HEATER1, HEATER2, ACCU MEATER FM PS PD 63H1, 63H2 MG-SW OCR RED : RED WHI : WHITE YEL : YELLOW BLU : BLUE BLK : BLACK GRY : GRAY PNK : PINK ORN :ORANGE BRN : BROWN GRN : GREEN Color indication Central remote controller U1 U2 U3 U4 U5 U6 Outdoor unit U1 U2 Indoor unit WHI WHI BLU BLU RY508 RY509 CR508 CR509 Parts name Compressor Pulse motor valve 2-way valve coil 4-way valve coil Compressor case thermo. Pipe temp. sensor (Inlet) Pipe temp. sensor (Outlet) Heat exchange temp. sensor Air temp. sensor Oil temp. sensor Liquid temp. sensor Case heater, 230V, 26W Fan motor (DC) Low pressure sensor High pressure sensor High pressure switch Magnet switch Overcurrent relay L3 CR517 RY517 RY516 RY507 CR507 CR516 RY506 CR506 RY502 RY503 RY504 L1 CN300 (WHI) 1 1 RY518 CN301 (WHI) 6 5 4 3 2 1 6 5 4 3 2 1 CR504 CR502 CR503 CN01 CN03 (BLU) (WHI) RED BRN BLU ORN YEL WHI 6 5 4 3 2 1 6 5 4 3 2 1 Accumulator heater 2 CN321 2 (RED) CR 518 RY510 CR511 SV 3E 4WV1 OCR MGSW Comp. IPDU No.1 MCC-1502 Power supply for fan MCC-1439 3 3 Interface control P.C. board (I/F) MCC-1429 Comp1 BLK BLK 3 1 3 1 ORN ORN Comp. IPDU No.2 MCC-1502 Fan IPDU MCC-896 Connecting terminal U1 U2 U3 U4 U5 U6 Comp2 5 5 7 7 1 1 T6.3A FUSE SW10 ON 1 2 3 4 CN305(RED) SW03 2 CN317 4 3 2 1 2 (BLU) 2 1 Parts layout Power supply terminal L1 L2 L3 N Noise filter P.C. board MCC-1366 SV 3D SW02 CN307(WHI) CR521 SW01 D600 D601 D602 D603 D604 SW32 RY521 SW30 SW09 ON 1 2 3 4 SW04 SW05 SW06 SW08 SW07 SW06 SW31 ON 1 ON 1 2 3 4 ON 1 2 3 4 SW14 SW13 SW12 SW11 1 2 3 4 CN323 1 1 2 3 4 (WHI) 1 CR 510 RY511 CN802 Flash 1 2 3 4 5 6 7 8 9 CN800 1 2 3 (Srvice) 4 5 6 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 SW30 ON 3 3 1 1 3 3 63H2 2 1 BLU BLU N L3 L2 L1 GRY BLK WHI RED Earth screw CN402 Transformer WHI CN401 RED CN600(WHI) 5 5 4 4 3 3 2 2 1 1 1 1 3 3 Option board TL (WHI) TK4 (GRN) TK3 (BLU) TK2 (BLU) TK1 (BLK) TO (BLK) TE1 (BLK) TS1 (GRY) TD2 (RED) TD1 (YEL) RED V U + Ð CM2 BLK WHI RED YEL BLU CN25 3 (WHI) 3 3 1 5 4 3 2 1 BLK WHI BLU RED PNK W V U CN26 (BLU) 1 1 GRY BLK WHI RED BLK 5 4 3 2 1 1 1 5 4 3 2 1 1 1 3 3 W V U BLK Ð + BLK CN18 CN19 CN02 CN03 1 1 3 3 3 3 BLU Reactor CN08 WHI CN15 CN13 YEL 1 1 6 5 A1 A2 4 3 Mg-SW 1 2 GRY 6 4 OCR 2 RED BLK WHI RED RED CN20 WHI 1 1 Ð PTC Themistor RED BLK WHI RED CN07 WHI CN17 (BLK) T CN02 S CN01 R CN18 (RED) 5 4 3 2 1 5 4 3 2 1 3 3 RED RED RED WHI BLK BLK GRY GRY GRY IPDU Board (2) MCC-1502 CN03 CN11 CN10 CN09 CN22 CN23 CN06 (WHI) 5 4 3 2 1 5 4 3 2 1 1 1 CN04 CN20 CN22(WHI) CN23(BLU) CN17 CN01 CN21 Ð Reactor CN21 WHI BLU CN15 CN13 CN17 (BLK) 3 3 YEL BLU 1 1 3 3 5 5 1 1 3 3 + T CN02 S CN01 R IPDU P.C. Board (1) MCC-1502 CN03 CN18 (RED) 1 2 3 4 5 1 2 3 4 5 5 4 3 2 1 5 4 3 2 1 CN06 (WHI) 1 2 3 4 5 1 2 3 4 5 CN501 (RED) CN505(RED) 1 2 3 4 5 CN504 (WHI) Noise filter P.C. board MCC-1366 + 3 3 1 1 CN506(BLK) CN502 (BLU) Power supply P.C. board for FAN CN503 MCC-1439 CN500 (WHI) CN11 CN10 CN09 CN22 CN23 CN26 (BLU) CN25 3 (WHI) 3 5 4 3 2 1 YEL BLU 1 1 2 2 BLU 3 3 BLK WHI CM1 RED YEL BLU YEL CN01 (WHI) FAN IPDU P.C. Board MCC-896, 897 W FM WHI 3. 2. , and indicate the terminal blocks and the numerals indicate the terminal numbers. indicates P.C. board. (Otherwise water enters into the box resulting in a trouble.) *Be sure to fix the electric parts cover surely with two screws. , accessories sold separately and service cables, respectively. 1. The two-dot chain line indicates wiring at the local site, and the dashed line indicates Power Supply 3phase 380-415V 50Hz 380 60Hz 1 2 3 4 CN400 3 2 1 1 2 3 4 (WHI) CN325 (YEL) CN100 (BLK) CN511 (GRN) 4 3 2 1 4 3 2 1 BLU(BLK) BLU(BLK) BLU(BLK) BLU(BLK) CN521 (WHI) 1 1 3 3 1 1 3 3 1 1 BLU(BLK) BLU(BLK) BLK 2 2 BLK 1 1 CN523 (YEL) CN516 (RED) CN515 (GRN) 3 3 BLU(BLK) BLK 2 BLK 1 BLK 2 BLK 1 BLU(BLK) 3 1 1 3 2 1 CN507 (YEL) CN514 (BLK) BLU(BLK) BLU(BLK) BLU(BLK) BLU(BLK) BLK 2 2 BLK 1 1 1 1 3 3 1 1 3 3 CN505 (GRN) CN504 (WHI) CN503 (PNK) CN308 (BLU) CN502 (WHI) 63H1 CN306 (WHI) 1 1 T6.3A FUSE T6.3A FUSE CN512 (BLU) CN513 (BLU) CN510 (WHI) CN509 (BLK) CN508 (RED) CN501 (RED) CN500 (WHI) Interface Control P.C. Board MCC-1429 4 3 2 1 4 3 2 1 5 4 3 2 1 5 4 3 2 1 4 3 2 1 4 3 2 1 4 3 2 1 4 3 2 1 Option Board Option Board 4 3 2 1 4 3 2 1 Option Board Option Board 4 3 1 4 3 2 1 RED BLK WHI 4 3 2 4 3 2 1 PNK PNK PNK PNK 3 2 1 3 2 1 BLK(PNK) 2 1 2 1 Option Board BLK(PNK) U1 U2 U3 U4 U5 U6 WHI Pressure Sensor PD ORN ORN RED BRN BLU ORN YEL WHI BRN RED BLK Pressure Sensor PS BLU PMV2 RED BLK Except 5HP, 6HP RED WHI BLK GRY L1 L2 L3 N YEL BLK WHI BLU RED PNK BLK BLK WHI BLU RED PNK PMV1 PNK RED BLU WHI BLK YEL YEL BLK WHI BLU RED PNK BLU PNK RED BLU WHI BLK BLU 1 2 1 2 2. Outdoor Unit Model: MMY-MAP0501HT , MAP0601HT , MAP0801HT , MAP1001HT , MAP1201HT 11 107 108 12 Controls 109 Foreword 110 LONWORKS Weekly timer RBC-EXW21E2 Master ON/OFF signal Batch drive, error output Energy monitoring Local supply“ TCS-Net Interface BMS-IFLSV1E Energy meter relay I/F Interface BMS-IFWH3E BMS-LSV2E Intelligent server Air-conditioning Management System on site Power peak-cut control signal Control remote controller TCB-SC642TLE2 Alarm Status output ON/OFF Command External master ON/OFF board TCB-PCDMO2E Power peak-cut control board TCB-PCDM2E LON Gateway 1 BACnetTM : ANSl/ASHRAE135Ð1995, A Data CommuniCation Protocol for Bulding Automation and ControI Networks. 2 LoNWoRKS¨, Resisterd trademark of Echelon Corporation Operation status output Operation control command Monitoring Remote control Schedule operation Error code indication Alarm list indication Monthly report Energy monitoring data etc. Touch screen controller Master ON/OFF signal Side remote controller Master remote controller Weekly timer RBC-EXW21E2 Remote location ON/OFF control board TCB IPCB-4E Super Modular Multi Outdoor Unit Wired remote controller RBC-AMT21E Simple remote controller Wireless remote RBC-AMT31E RBC-AS21E2 controller ``1:1model`` connection interface TCB-PCNT301TLE2 AI-NET Central control devices AI-NETWORK Network adapter TCB-PCNT20E Super Digital Inverter Digital Inverter 12 Controls Foreword 1:1 Outline of application Control 12 111 1. Applications for indoor remote controller Basic function Individual control 1-1 Model Main remote controller Wireless remote controller Wired remote controller RBC-AMT21E RBC-AMT31E Simple wired remote controller RBC-AS21E2 Wireless remote controller kit TCB-AX21U(W)-E2 RBC-AX22CE2 TCB-AX21E2 Indoor unit Indoor unit Possible up to Max. total length 500m Remote controller ((( Air conditioner is individually operated at a distance. System diagram Receiver unit Wireless CAUTIONS Remote controller Max.8 indoor units GROUP control 1-2 One remote controller can control a group of up to a maximum. 8 indoor units. Operating on the same setting Indoor unit Indoor unit Indoor unit Remote controller Possible up to Max.total length 500m Wired system Wireless system Indoor unit Indoor unit Air conditioner is controlled by two remote controllers in two locations. 12 Master Side ( 1-3 Wireless remote controller 1 Master Remote Remote controller controller (( ((( Two remote control Indoor unit Wireless remote controller2 Side Possible up to Max. total length 500m Wired remote controller RBC-AMT21E RBC-AMT31E Simple wired remote controller RBC-AS21E2 Wired remote controller RBC-AMT21E RBC-AMT31E Simple wired remote controller RBC-AS21E2 Wireless remote controller kit TCB-AX21U(W)-E2 RBC-AX22CE2 TCB-AX21E2 Indoor unit (( ( Wired & Wireless combination control (Either one of the two controllers can be set as side control.) Remote controller Wireless remote controller Weekly timer function 1-4 Control by weekly timer Weekly schedule operation Indoor unit Wired remote controller RBC-AMT21E RBC-AMT31E + Weekly timer RBC-EXW21E2 Remote controller 112 Setting of ON-OFF 3 times par day Timer operation time is displayed. Holiday period Weekly timer Foreword 2. Application controls for central remote controller Basic function Model System diagram Header unit U3, U4 Outdoor unit Line-3 Indoor unit U5, U6 U1, U2 Zone 4 Header unit Indoor remote controller U3, U4 Outdoor unit U5, U6 Line-2 Indoor unit U1, U2 Zone 3 Zone 2 U3, U4 Outdoor unit Line-1 2-1 Central management controller for 64 units Central remote controller TCB-SC642TLE2 Indoor remote controller Header unit <Indoor remote controller> Wired remote controller RBC-AMT21E RBC-AMT31E Indoor unit U1, U2 Zone 1 Indoor remote controller Power Central supply remote controller Single phase 220/230/240V Simple wired remote controller RBC-AS21E2 Function of central remote controller Individual control for up to 64 indoor units Individual control for max. 64 indoor units divided in to 4 zones. (Up to 16 indoor units for each zone.) Up to 16 outdoor header units are connectable. 4 specific central control settings to restrict individual operation by remote controller are selectable. Different settings for 1 to 4 zones. Usable with other central control devices (Up to 10 central control devices in one control circuit) Two selectable control modes Central controller mode/Remote controller mode Setting of simultaneous ON/OFF 3 times per day of the week combined with weekly timer. U3, U4 Outdoor unit Central remote controller + 2-2 Weekly timer Weekly operation schedule can be set by connecting a weekly timer to the central remote controller Indoor unit Indoor remote controller Single phase 220/230/240V Power supply Central remote controller Weekly timer U1, U2 12 Central remote controller TCB-SC642TLE2 + Weekly timer RBC-EXW21E2 Indoor remote controller Wired remote controller RBC-AMT21E RBC-AMT31E or Simple wired remote controller RBC-AS21E2 113 Basic function System diagram U3, U4 Model Outdoor unit U1, U2 Power supply Indoor unit Central remote controller Single phase 220/230/240V 2-3 Either one of the two controllers can be set as side control. without indoor remote controller Even when grouping operation is performed by connecting multiple indoor units to 1 line, the indoor remote controller is required. Central remote controller TCB-SC642TLE2 Example of grouping operation U3, U4 Power supply Outdoor unit U1, U2 (Group) Indoor remote controller is required Central remote controller Single phase 220/230/240V U3, U4 Available Indoor remote controller Wired remote controller RBC-AMT21E RBC-AMT31E Outdoor unit U1, U2 (Group) Power supply Available Single phase 220/230/240V Central remote controller Power supply 12 Central remote controller TCB-SC642TLE2 TCB-CC163TLE2 Central remote controller U3, U4 2-4 Central management control with ‘‘1 : 1 model’’ Header unit Super MMS U1, U2 Indoor unit *1 ‘‘1:1 model’’ connection interface Indoor remote controller * TOSHIBA Digital Inverter System and Super Digital Inverter System 114 ‘‘1 : 1 model’’ connection interface TCB-PCNT30TLE2 RAV-SM560KRT-E, SM800KRT-E are not compatible to connect Indoor remote controller Wired remote controller RBC-AMT21E RBC-AMT31E Simple wired remote controller RBC-AS21E2 3. Application control for network Basic function 3-1-1 System diagram Model LONWORKS LN interface TCB-IFLN640TLE ‘‘1 : 1 model’’ connection interface TCB-PCNT30TLE2 RAV-SM560KRT-E, SM800KRT-E are not compatible to connect LON Center LON WORKS LN Interface TCB- TCBTCBIFLN060 • • • Super MMS Remote controller *1 ``1:1 model`` connection interface *1 TOSHIBA Digital Inverter System and Super Digital Inverter System Indoor remote controller Wired remote controller RBC-AMT21E RBC-AMT31E or Simple wired remote controller RBC-AS21E2 The LONWORKS interface should be connected between a building management computer and a Super MMS air conditioning system. 3-1-2 BACnet BACnet center Local server BACnet local server BMS-LSV2E TCB- TCB- TCS-Net Relay Interface Super MMS Remote controller *1 ``1:1 model`` connection interface *1 TOSHIBA Digital Inverter System and Super Digital Inverter System TCS-Net Relay Interface BMS-IFLSV1E ‘‘1 : 1 model’’ connection interface TCB-PCNT30TLE2 RAV-SM560KRT-E, SM800KRT-E are not compatible to connect 12 Indoor remote controller Wired remote controller RBC-AMT21E RBC-AMT31E Simple wired remote controller RBC-AS21E2 The local server should be connected to the BACnet network, and the Super MMS air conditioning system through the interface. 115 Touch screen controller system System Diagram Intelligent Server Software Ethernet connection RS-485 Control wiring Outdoor units TCS-Net Relay Interface Intelligent Server Touch Screen Controller Indoor units Control wiring Remote controller Control Maximum 512 FCU Control wiring Maximum 4 Intelligent server Maximum 8 Relay Interface Maximum 4 Energy Monitoring Relay Interface I/F Energy Meter Relay Interface Fire alarm Door Key Entry ON/OFF Error code output 3-2-1 Maximum 8 Power Meter Maximum 4 Digital I/O Relay Interface Digital I/O Relay Interface Function Devices Model Name Touch Screen controller (English version) 12 I/F Local supply 1kWh/pulse or 10kWh/pulse 50-1000 ms Pulse Signal Intelligent Server Intelligent Server Software TCS-Net Relay Interface Energy Monitoring Relay Interface Digital I/O Relay Interface Model Name BMS-TP0640ACE BMS-TP5120ACE BMS-TP0640PWE BMS-TP5120PWE BMS-LSV2E BMS-STCC01E BMS-IFLSV1E BMS-IFWH3E BMS-IFDD01E Specification Max 64 FCU , without electrical bill calculation Max 512 FCU , without electrical bill calculation Max 64 FCU , with electrical bill calculation Max 512 FCU , with electrical bill calculation Server in between Touch Screen controller & RS-485 Installed on Intelligent Server I/F in between Intelligent server & Control wiring I/F for Power Meter I/F for I/O signal (1) Monitoring air-conditioners Operation status can be viewed according to a unit. Unit All building, All tenants, Each tenant, Each area, Each air-conditioning system Monitoring contents Operation and alarm status, Setting status for each air-conditioning system (2) Operating of air-conditioners Header / individual control can be performed according to a unit. Operating contents ON/OFF, Operation setting (operation mode, air volume, louver position, setting temp., restricted setting from remote location) (3) Schedule operation Air-conditioners are operated according to the set-up schedule / operation pattern. Schedule opretaion can be performed according to a unit. Operation pattern Weekly pattern, special day pattern (4 pattern), Non-operation days pattern (4) Alarm list display The present alarm contents are list-displayed. Display contents Alarm contents, Unit number, Generated time The alarm history records are displayed. Display contents Alarm contents, Unit number, Generated time Monthly report data is wrtten to ‘‘Compact Flash’’. Monthly reports can be created according to a unit using the monthly report software. Monthly report contents The number of ON/OFF, Operating time, Results of energy monitoring (5) Alarm record display (6) Monthly report data extraction (7) Energy monitoring data extraction Power consumption data is written to ‘‘Compact Flash’’. Energy monitoring can be performed according to a unit using the energy monitoring software. Energy monitoring data Power consumption according to the power meter 116 3-2-2 Basic function System diagram Windows based central controller (Now planning) Personal computer on site Model server Relay Interface *1 Super MMS Remote controller ‘‘1:1 model’’ connection interface Energy monitoring relay interface Digital I/O relay interface *1 TOSHIBA Digital Inverter System and Super Digital Inverter System 12 117 Application control of optional devices connectable to indoor units Remote location ON/OFF control box Model Name Appearance Features Start and stop of the air conditioner is possible by a external signal and indication of operation/alarm externally. TCB-IFCB-4E Application Function Monitoring ON/OFF status (for indoor unit) Alarm status (system & indoor unit stop) ON/OFF command Air conditioner can be turned ON/OFF by external signals. The external ON/OFF signals will initiate the signals shown below. Operation Interface Display Remote Controller ON /OFF COM Non-voltage ON /OFF continious signal Network adapter Model Name Appearance Features Indoor units of Super MMS system are controlled by AI-NETWORK central remote controller. Connectable indoor units per group. 12 TCB-PCNT20E Connection of cables Install optional P.C. board in Electrical parts box of indoor unit. Application Power Supply AI Network Wiring diagram of indoor P.C. board Central Remote Controller TCB-SC641E Network Adapter Indoor unit 118 ‘‘1:1 model’’ connection interface Model Name Appearance Features Link adapter for ‘‘1:1 model’’ into super modular muti network 1:1 model : Super digital inverter Digital inverter TCB-PCNT30TLE2 Connection of cables Install optional P.C. board in Electrical parts box of indoor unit. ON-OFF control devices Application TCB-CC163TLE2 Central Remote Controller TCB-SC642TLE2 Super MMS control wiring Wiring diagram of indoor P.C. board 1:1 model connection interface Indoor units Digital Inverter Super Digital Inverter adoptor Outdoor unit 12 119 Application controls by optional P.C. board of outdoor unit Model Name Appearance Function 1 Power peak-cut Control Feature The upper limit capacity of the outdoor unit is restricted based on the power peak cut request signal from outside. Size : 71 x 85 Function Two types of control can be selected by setting SW07 on the interface P.C. board on the header outdoor unit. TCB-PCDM2E Local Supply ON Application TCB-PCDM2E OFF SW2 COM *Install this optional P.C. board in the inverter assembly of the header outdoor unit. 12 SW1 COM Standard funciton SW07-2 OFF Input SW01 SW02 ON OFF OFF ON SW07-1 OFF ON 0% (stop) Up to 60% 100%(Nomal) 100%(Normal) Expansion function SW07-2 ON Input SW01 SW02 OFF OFF ON OFF OFF ON ON ON SW07-1 ON OFF 100%(Nomal) 100%(Normal) Up to 80% Up to 85% Up to 60% Up to 75% 0%(stop) Up to 60% Ensure terminal contacts are securely fixed. Do not turn on both SW1 and SW2 terminals simultaneously. 120 Model Name Appearance Function 2 Snowfall fan control Feature Outdoor fan is operated by a snowfall signal from outside. Function TCB-PCMO2E Local Supply COM TCB-PCM02E SMC Size : 55.5 x 60 Cooling Application SMC : Cooling mode select input (switch) Terminal Input signal Operation ON Snowfall fan control (Operates outdoor fan.) SMC OFF ON Usual operation OFF This control is activated when a input signal increases or decreases. (The increasing or decreasing signal needs to be held for a minimum of 100m/sec in order to activate the control). 3 External master ON/OFF control Feature The outdoor unit starts or stops the system. Function TCB-PCMO2E Local Supply COM SMC Cooling Heating *Install this optional P.C. board in the inverter assembly of the header outdoor unit. SMH 12 SMC : Input signal for start SMH : Input signal for stop Terminal Input signal Operation Starts all indoor units. ON SMC SMH ON OFF Stops all indoor units. OFF Ensure terminal contacts are securely fixed. This control is activated when a input signal increases or decreases. (The increasing or decreasing signal needs to be held for a minimum of 100m/sec in order to activate the control). 121 Model Name Appearance Function 4 Night operation (Sound reduction) control Feature Sound level can be reduced by restricting the compressor and fan speeds. Function TCB-PCM02E TCB-PCMO2E Size : 55.5 x 60 Local Supply COM SMC Cooling Application SMC : Cooling mode designated input switch Terminal Input signal Operation ON Night operation control OFF ON SMC Usual operation OFF This control is activated when a input signal increases or decreases. (The increasing or decreasing signal needs to held for a minimum of 100m/sec in order to activate the control). 5 Operation mode selection control Feature This control can restrict the selectable operation mode. Function 12 *Install this optional P.C. board in the inverter assembly of the header outdoor unit. TCB-PCMO1E Local Supply COM SMC Cooling Heating SMH SMC : Cooling mode designated input switch SMH : Heating mode designated input switch SMC ON SMH OFF OFF ON Selected operation mode Only cooling mode permitted Only heating mode permitted Ensure terminal contacts are securely fixed. 122 Remote controller Wired remote controller RBC-AMT31E 120 120 84 18 62 16 RBC-AMT21E 2.7 4 120 12 16 120 123 Simple wired remote controller 60 70 12 124 120 80 RBC-AS21E / RBC-AS21E2 13 16 Wireless remote controller TCB-AX21U (W)-E / TCB-AX21U (W)-E2 186 19.5 32 177 186 58 61 Wireless remote controller kit RBC-AX22CE / RBC-AX22CE2 130 19.5 12 177 65 58 61 125 Wireless remote controller kit TCB-AX21E / TCB-AX21E2 58 19.5 83.5 177 83.5 4.4 x 9.4 long hole 13 70 4.4 x 5.4 long hole 61 Weekly timer RBC-EXW21E / RBC-EXW21E2 2.7 4 120 12 16 120 126 Remote sensor 120 80 TCB-TC21LE / TCB-TC21LE2 13 60 70 16 Central remote controller TCB-SC642TLE / TCB-SC642TLE2 160 148 21 69 Z 115 (6) 121 6 148 (6) 160 6 13 15 116 47 12 121 47 80 128 36 13 128 80 Z view (back side) 127-1 127 ON-OFF controller TCB-CC163TLE2 116 Unit: mm 160 (6) 148 14 69 115 121 148 (6) 160 6 6 Z 122 4-Ø5 diameter holes (for mounting) 128 Hole for electrical wiring 80 47 80 128 36 13 12 4-Ø5.5 diameter holes (for mounting) Z-view (back side) 128 127-2 TCS-Net relay interface BMS-IFLSV1E 200 6- 5.5 mounting holes 78 78 22 22 78 78 22 66 63.6 156 170 146.9 22 Touch screen controller BMS-TP0640ACE BMS-TP5120ACE BMS-TP0640PWE BMS-TP5120PWE 256 91.75 70 99.3 75 242 95.75 75 302 55.5 19 30 82.5 48 16 5 12 316 249 54 49 127-3 129 Intelligent server 39 CAUTION Do not remove. 198 BMS-LSV2E 370 WARNING Do not decompose. Energy monitoring relay interface / Digital I/O relay interface BMS-IFWH3E BMS-IFDDO1 63.6 200 (2.4) 5.5 mounting hole 63.6 130 128 78 78 22 12.55 22 170 144.9 146.9 7 156 7 6 12.55 (2.4) 12 Dimension TCB-PCDM2E 71 Terminal Screw M3 x 6 4-4ø hole 75 85 61 Terminal Screw M4 x 8 TCB-PCMO2E 55.5 4-4ø hole 45.5 50 60 Terminal Screw M3 x 6 12 TCB-PCIN2E 4- 4 hole 63 73 79 69 Terminal (Screw M3 ) 129 131 12 130 132 13 Fan characteristics 131 Foreword 13 132 13 Fan characteristics Foreword A MMD-AP0121BH Standard air volume:480m3/h gh Hi ati cp 120 res su lim it -st re 2 H at pl Ap Sta Lo 40 w sta Sta nd tic nd ard pre ard tat H ss ic ss ure 1H tap tap ure Lt pre H tap Ap 100 80 60 ic pl a ti on lim Lo 40 w Sta an sta nd ap gh da rd tic sta H pr es ard Lt tic ta pr es long life filter 0 200 0 300 600 480 H su re 2 su re H ta H ta p tap p ap Air volume(m /h) MMD-AP0181BH Standard air volume:650m3/h 140 Standard air volume:780m3/h 140 Hig ic Hig h st Sta Low sta tic atic nda pre 40 Sta nda pre ssu re 1 rd H tap pre H ta ssu p re 2 H tap A 100 80 60 Air volume limit (Min) pl tatic External static pressure (Pa) Air volume limit (Min) Ap at ion lim it h-s 120 Air volume limit (Max) Hig 120 100 700 570 3 MMD-AP0151BH External static pressure (Pa) re 1 pr es p 500 Air volume(m /h) l pp ti ica o i nl ssu re H Hig Sta hs nda rd sta tat Sta rd Lt ap nd 20 ic p Ht tic 40 tap h-s t mi Low 20 ard res s tat ic p ure 1H ap pre Lt ssu re H res s ure tap 2H tap 13 tap ap long life filter long life filter 0 400 su tic long life filter 400 3 60 ta 20 20 80 -s it Hi St gh Air volume limit (Max) 60 hs tap Air volume limit (Max) n io 80 Hig ic 100 Air volume limit (Min) External static pressure (Pa) 120 Air volume limit (Min) Hi Standard air volume:570m3/h 140 External static pressure (Pa) 140 Air volume limit (Max) MMD-AP0071BH, AP0091BH 600 650 Air volume(m3/h) 800 0 500 700 780 900 Air volume(m3/h) 133 MMD-AP0241BH, AP0271BH MMD-AP0301BH Standard air volume:1140m3/h on High Air volume limit (Min) 100 80 60 static Stand Low static press ure 1 H tap ard H tap 2H ta p Ap plic ure H tap 100 High 80 60 Stan ard L tap 1000 0 900 1200 1140 pres sure re 2H tap 1H ta p H ta p ure H tap dard L tap 1100 MMD-AP0481BH, AP0561BH Standard air volume:1980m3/h High Air volume limit (Min) 100 static Stan Low dard static Stan dard pres ic pre ssu sure sure re 2H tap 1H t ap H ta p pres 40 -stat 120 H ta p 100 80 60 c pli o ati im nl Hig it Hig h st Sta Low stat h-s atic nda Sta L tap pre ic p ress u nda tati cp ssu res s re 1 ure H ta 2H p rd H tap 40 20 re H tap rd L tap 20 long life filter 0 1200 Ap Air volume limit (Min) ca pli tio i nl High t mi 140 External static pressure (Pa) 120 Air volume limit (Max) 140 long life filter 1620 Air volume(m3/h) 2000 0 1400 1800 1980 Air volume(m3/h) 2200 tap Air volume limit (Max) Standard air volume:1620m /h 3 Ap 1260 1300 Air volume(m3/h) MMD-AP0361BH External static pressure (Pa) ic pre ssu long life filter Air volume(m3/h) 134 static dard press -stat 20 0 800 60 static Stan long life filter 13 nl t imi 40 20 80 atio Low press 40 Stand High 120 Air volume limit (Min) ati ic pre ssure External static pressure (Pa) A lic pp lim it -stat Air volume limit (Max) High 120 External static pressure (Pa) Standard air volume:1260m3/h 140 Air volume limit (Max) 140 Foreword Concealed Duct High Static Pressure type MMD-AP0241H, AP0271H Standard air volume: 900 m3/h 1.5 High static pressure tap Medium static pressure tap 1.0 Low static pressure tap 0.5 Fan motor current (A) Fan motor current (A) MMD-AP0181H 2.0 Standard air volume: 1320 m3/h High static pressure tap Medium static pressure tap 1.5 Low static pressure tap 1.0 300 250 w m st at ic es pr es st at m st at ic pr es 100 p 900 su re re ta ta p p 1000 p 800 su ta 50 700 es re 0 iu pr su ta ed ic es re 50 p 150 M at pr su ta 200 ic es re ap st at pr su re t gh st ic su Hi Air volume upper limit iu pr Air volume lower limit Lo ed tic 50Hz 60Hz w 100 M sta 250 Outside static pressure (Pa) 150 Air volume lower limit 200 50Hz 60Hz Air volume upper limit gh Lo Outside static pressure (Pa) Hi 0 1000 1100 1100 1320 1300 1400 1200 1500 1600 Air volume (m3/h) Air volume (m3/h) MMD-AP0361H MMD-AP0481H Standard air volume: 1600 m3/h Standard air volume: 2100 m3/h 3.0 Fan motor current (A) Fan motor current (A) 2.5 High static pressure tap 2.0 Medium static pressure tap 1.5 Low static pressure tap High static pressure tap 2.5 2.0 Medium static pressure tap 1.5 1.0 Lo Low static pressure tap 100 diu m Lo 50Hz 60Hz tati sta w cp tic sta res pre tic sur e ta ssu pre ss re t ure 50 0 1400 1500 1600 ap tap 1700 Air volume (m3/h) p 250 200 150 Hi M ed iu Lo 100 gh sta m w st st at 50Hz 60Hz tic at ic ic pr pr es pr es es su su su re 50 1800 0 re t re ta ap ta Air volume upper limit 150 Me hs Air volume lower limit 200 Air volume lower limit Outside static pressure (Pa) Hig Outside static pressure (Pa) 250 Air volume upper limit 0.5 13 p p 2100 1500 2000 2500 Air volume (m3/h) 135 MMD-AP0721H Standard air volume : 3600m3/h 8 High static pressure tap (60Hz) Current of fan motor (A) 7.5 7 Medium static pressure tap (60Hz) Low static pressure tap (60Hz) 6.5 6 High static pressure tap (50Hz) Medium static pressure tap (50Hz) 5.5 5 4.5 Low static pressure tap External static pressure (Pa) 4 300 High static pressure tap (50Hz) 250 200 150 High static pressure tap (60Hz) 100 50 Medium static pressure tap (50Hz) Medium static pressure tap (60Hz) Low static pressure tap (50Hz) 5 2880 3000 3200 3400 3600 3800 4000 4200 4320 Air volume (m3/h) Lower limit of air volume Low static pressure tap (60Hz) Upper limit of air volume MMD-AP0961H Standard air volume : 4200m3/h 8.5 Current of fan motor (A) 8 High static pressure tap (60Hz) Medium static pressure tap (60Hz) Low static pressure tap (60Hz) 7.5 7 High static pressure tap (50Hz) 6.5 Medium static pressure tap (50Hz) 6 5.5 5 Low static pressure tap 4.5 13 External static pressure (Pa) 4 350 High static pressure tap (60Hz) 300 High static pressure tap (50Hz) 250 200 150 100 50 5 3360 Lower limit of air volume Medium static pressure tap (50Hz) Low static pressure tap (50Hz) Low static pressure tap (60Hz) 3600 4000 4400 Air volume (m3/h) 4800 5040 Medium static pressure tap (60Hz) Upper limit of air volume REQUIREMENT Add a air volume damper to the supplied air duct, and adjust the air volume from 80% to 120% of the standard air volume. 136 AIR SPEED CHARACTERISTICS Air Speed Distribution B 4-way air discharge cassette type MMU-AP0091H, AP0121H MMU-AP0151H 2.8m 2.7m 0.7m/s 2 0.3m/s 2 0.5m/s 0.5m/s 0.7m/s 1 1 0.3m/s 0 0 1 2 3 4 1 2 3 4 5m 5m MMU-AP0181H MMU-AP0241H,AP0271H 3.6m 3 2.8m 0.7m/s 2 0.7m/s 1 1 2 3 4 0.3m/s 1 0.3m/s 0 0.5m/s 2 0.5m/s 0 5m 1 2 3 4 5m MMU-AP0301H MMU-A0361H 3.6m 3 3.6m 2 0.7m/s 3 0.7m/s 0.5m/s 2 0.5m/s 0.3m/s 1 1 0.3m/s 0 0 1 2 3 4 1 2 3 4 5m 5m MMU-AP0561H MMU-A0481H 3.6m 3 0.7m/s 3.6m 3 0.3m/s 0.5m/s 2 1 0.3m/s 1 0 0.5m/s 2 0.7m/s 1 2 3 13 4 5m 0 1 2 3 4 5m 137 Air Speed Distribution 2-way air discharge cassette type MMUAP0071WH, AP0091WH, AP0121WH MMUAP0151WH, AP0181WH 2.7m Ceiling height (m) Ceiling height (m) 2.7m 2 1.0 0.5 (m) 1 0.3 0.3 0 1 2 2 1.0 (m) 1 0.5 0.3 0.3 0 3m Horizontal distance (m) 1 2 3m Horizontal distance (m) MMU-AP0241WH, AP0271WH Ceiling height (m) 2.7m 2 1.0 (m) 1 0.5 0.3 0.3 0 1 2 3m Horizontal distance (m) MMU-AP0481WH MMU-AP0301WH 13 2.7 Ceiling height (m) Ceiling height (m) 2.7 2 1.0 1 0.5 0.3 0 1.0 1 0.3 1 2 3 Horizontal distance (m) 138 2 0.5 0.3 0.3 4 0 1 2 3 Horizontal distance (m) 4 Air Speed Distribution 1-way air discharge cassette type MMU-AP0071YH, AP0091YH, AP0121YH H (High wind, blowing downward) 2.7m L (Low wind, blowing downward) 5.0 4.0 2.7m 2 2 H (High wind, blowing horizontally) 2.7m 4.5 1.7 2 2.5 L (Low wind, blowing horizontally) 2.7m 3.0 0.3 2 1.5 0.4 1.5 1.1 0.3 2.3 1 1 1 0.4 0 0.6 1 1 0.5 0.9 0.4 2 3m 0.2 0 0.2 0.3 1 2 3m 0 MMU-AP0151SH,AP0181SH 1 2 3m 0 1 2 3m MMU-AP0241SH 2.7m 2.7m 2 2 1.0 1.0 0.3 0 0.5 1 1 0.5 1 0.3 0.3 2 0.3 0 3m 1 2 3m Under ceiling type MMC-AP0181H,AP0481H 1m MMC-AP0361H 1m 2m 2m 1.0 3m 0.3 1m 0.3 0.5 3m 0.5 2m 1.0 0.3 0.3 0.5 3m 4m 1m 2m 3m 13 4m MMC-AP015H,AP0241H,AP0271H 1m 2m 1.0 3m 0.3 0.3 1m 2m 0.5 3m 4m 139 Discharge Air Speed and Air Throw High wall type MMK-AP0071H, AP0091H, AP0121H High wind: 5.0m/s Med. wind: 4.4m/ s 4 3 2 1 0 1 2 3 4 5 6 High wind: 5.0m/s Med. wind: 4.4m/ s Horizontal discharge Initial speed 5 Air speed (m/s) Horizontal discharge Initial speed 5 Air speed (m/s) MMK-AP0151H, AP0181H 7 4 3 2 1 0 1 2 Horizontal throw (m) 3 4 5 6 7 Horizontal throw (m) MMK-AP0241H High wind: 5.0m/s Med. wind: 4.4m/ s Air speed (m/s) Horizontal discharge Initial speed 5 4 3 2 1 0 1 2 3 4 5 6 7 Horizontal throw (m) Floor standing cabinet type High wind 2 Med. wind Low wind 1 0 1 2 3 4 5 6 7 Distance from discharge grille (m) 3 High wind Med. wind Low wind 2 1 0 1 2 3 4 5 6 7 Distance from discharge grille (m) MML-AP0181H, AP0241H Air speed (m/s) 3 MML-AP0121H, AP0151H Air speed (m/s) Air speed (m/s) 13 MML-AP0071H, AP0091H 4 High wind 3 Med. wind 2 Low wind 1 0 1 2 3 4 5 6 7 Distance from discharge grille (m) 140 8 Air Speed Distribution Floor standing type (m) MMF-AP0151H, AP0181H (m) 2.7 MMF-AP0241H, AP0271H 2.7 0.5m/s 2.0 2.0 0.5m/s 1.5m/s 1.0m/s 0.7m/s 1.5m/s 1.0 1.0m/s 1.0 1 2 3 4 5 6 7 8 (m) MMF-AP0361H (m) 1 (m) 2.7 2 3 4 5 6 7 8 (m) MMF-AP0481H,AP0561H 2.7 2.0 1.5m/s 2.0m/s 0.5m/s 1.0m/s 2.0 1.5m/s 1.0 1.5m/s 1.5m/s 1.0m/s 1.0 1 2 3 4 5 6 7 8 (m) 1 2 3 4 5 6 7 8 (m) 13 141 142 14 Sound characteristics (NC CURVE) 143 Foreword 144 14 Sound characteristics Foreword (NC CURVE) Sound level data (NC CURVE) Sound level values shown are based on a measurement in a non resound room. Microphone Octave band sound pressure level (dB) MMU-AP0091H, AP0121H Fan Tap H M L Sound pressure level(dB(A)) 30 29 27 Audibility limits of continous white sound Octave band frequency(Hz) MMU-AP0181H Fan Tap H M L Fan Tap H M L Sound pressure level(dB(A)) 31 29 27 Sound pressure level(dB(A)) 32 29 28 Octave band sound pressure level (dB) Octave band sound pressure level (dB) MMU-AP0151H Audibility limits of continous white sound Octave band frequency(Hz) Audibility limits of continous white sound Octave band frequency(Hz) Octave band sound pressure level (dB) MMU-AP0241H, AP0271H Fan Tap H M L Sound pressure level(dB(A)) 34 31 28 14 Audibility limits of continous white sound Octave band frequency(Hz) 145 Sound level data (NC CURVE) MMU-AP0301H MMU-AP0361H H M L 37 33 30 Octave band sound pressure level (dB) Fan Tap Sound pressure level(dB(A)) Octave band sound pressure level (dB) Sound level values shown are based on a measurement in a non resound room. Audibility limits of continous white sound Fan Tap H M L Sound pressure level(dB(A)) 40 36 33 Audibility limits of continous white sound Octave band frequency(Hz) MMU-AP0561H Fan Tap H M L Fan Tap H M L Sound pressure level(dB(A)) 44 38 34 Sound pressure level(dB(A)) 45 48 34 Audibility limits of continous white sound Octave band frequency(Hz) 14 146 Octave band sound pressure level (dB) Octave band sound pressure level (dB) MMU-AP0481H Octave band frequency(Hz) Audibility limits of continous white sound Octave band frequency(Hz) Foreword Sound level data (NC CURVE) Sound level values shown are based on a measurement in a non resound room. MMU-AP0071WH, AP0091WH, AP0121WH Fan Tap H M L Sound pressure level(dB(A)) 34 32 30 Microphone Octave band sound pressure level (dB) standard sound pressure 0.0002 µbar Audibility limits of continous white level Octave band frequency (Hz) MMU-AP0241WH, AP0271WH MMU-AP0151WH, AP0181WH Fan Tap H M L Sound pressure level(dB(A)) 35 33 30 Audibility limits of continous white level Octave band frequency (Hz) H M L 38 35 33 standard sound pressure 0.0002 µbar Octave band sound pressure level (dB) Octave band sound pressure level (dB) standard sound pressure 0.0002 µbar Fan Tap Sound pressure level(dB(A)) 14 Audibility limits of continous white level Octave band frequency (Hz) 147 Sound level data (NC CURVE) MMU-AP0301WH MMU-AP0481WH H Fan Tap Sound pressure level(dB(A)) 40 M L 37 34 H M L 45 42 39 90 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 H M 20 Audibility limits of continous white level NC-20 L 10 63 125 250 500 1000 2000 4000 8000 Octave band sound pressure level (dB) 90 Octave band sound pressure level (dB) Fan Tap Sound pressure level(dB(A)) 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 H M 30 NC-30 L 20 NC-20 Audibility limits of continous white level 10 63 Octave band center frequency (Hz) 125 250 500 1000 2000 4000 MMU-AP0151SH, AP0181SH Fan Tap H M L Sound pressure level(dB(A)) 42 39 36 Octave band sound pressure level (dB) Microphone NC-70 NC-60 NC-50 NC-40 NC-30 Audibility limits of continous white level Octave band frequency (Hz) MMU-AP0241SH 148 H M L 43 41 37 Octave band sound pressure level (dB) 14 Fan Tap Sound pressure level(dB(A)) NC-70 NC-60 NC-50 NC-40 NC-30 NC-20 Audibility limits of continous white level Octave band frequency (Hz) 8000 Octave band center frequency (Hz) NC-20 Sound level data (NC CURVE) MMD-AP0071BH, AP0091BH Fan Tap Sound pressure level (dB(A)) H M L 30 28 26 Octave band sound pressure level(dB) 90 Microphone 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 H M 30 NC-30 L 20 Audibility limits of white level NC-20 10 63 125 250 500 1000 2000 4000 8000 Octave band center frequency (Hz) MMD-AP0121BH MMD-AP0151BH H M L 31 29 27 Fan Tap Sound pressure level (dB(A)) 90 90 80 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 H 20 Audibility limits of white level NC-20 M L 10 Octave band sound pressure level(dB) Octave band sound pressure level(dB) Fan Tap Sound pressure level (dB(A)) H M L 31 29 27 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 H Audibility limits of white level 20 NC-20 M L 10 63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 Octave band center frequency (Hz) Octave band center frequency (Hz) MMD-AP0181BH Fan Tap Overall level dB(A) H M L 32 30 28 Octave band sound pressure level(dB) 90 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 H M 20 L Audibility limits of white level 14 NC-20 10 63 125 250 500 1000 2000 4000 8000 Octave band center frequency (Hz) 149 Sound level data (NC CURVE) MMD-AP0241BH, AP0271BH H M L 33 31 29 Fan Tap Sound pressure level (dB(A)) 90 90 80 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of white level Octave band sound pressure level(dB) Octave band sound pressure level(dB) Fan Tap Sound pressure level (dB(A)) MMD-AP0301BH 10 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 Audibility limits of white level 125 250 500 1000 2000 4000 8000 63 125 MMD-AP0361BH H M L 36 34 32 500 Fan Tap Sound pressure level (dB(A)) 90 80 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 NC-20 Audibility limits of white level 10 Octave band sound pressure level(dB) 90 20 250 1000 2000 4000 8000 MMD-AP0481BH, AP0561BH Fan Tap Sound pressure level (dB(A)) Octave band sound pressure level(dB) NC-20 Octave band center frequency (Hz) Octave band center frequency (Hz) H M L 38 36 32 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of white level NC-20 10 63 125 250 500 1000 2000 4000 8000 Octave band center frequency (Hz) 150 L 29 10 63 14 M 32 70 20 NC-20 H 34 63 125 250 500 1000 2000 4000 8000 Octave band center frequency (Hz) Sound level data (NC CURVE) Sound level values shown are based on a measurement in a non resound room. Microphone MMD-AP0181H (dB) 196.0 (Pa) Overall level A 33 37 40 C 46 51 53 (dB) (standard sound pressure 0.0002 µbar) 196.0(external static pressure(Pa)) Audibility limits of continous white level Octave band center frequency (Hz) MMD-AP0241H, AP0271H Outside still pressure 68.6 (Pa) Octave band sound pressure level (dB) (dB) Outside still pressure 68.6 (Pa) Octave band sound pressure level (dB) 137.2 (Pa) 196.0 (Pa) Overall level A 36 40 44 C 50 53 57 (dB) 137.2 (Pa) 196.0 (Pa) Overall level A 33 37 40 C 47 49 53 (dB) (standard sound pressure 0.0002 µbar) 196.0(external static pressure(Pa)) Audibility limits of continous white level Octave band center frequency (Hz) (dB) 137.2 (Pa) (standard sound pressure 0.0002 µbar) 196.0(external static pressure(Pa)) Audibility limits of continous white level Octave band center frequency (Hz) (dB) Outside still pressure 68.6 (Pa) Octave band sound pressure level (dB) Octave band sound pressure level (dB) Outside still pressure 68.6 (Pa) Overall level A (dB) C 137.2 (Pa) 196.0 (Pa) 36 40 44 50.5 53 57 (standard sound pressure 0.0002 µbar) 196.0(external static pressure(Pa)) 14 Audibility limits of continous white level Octave band center frequency (Hz) 151 MMD-AP0361H (dB) (dB) Overall level A (dB) C 36 49.5 137.2 (Pa) 196.0 (Pa) 40 44 54 Outside still pressure 68.6 (Pa) Octave band sound pressure level (dB) Octave band sound pressure level (dB) Outside still pressure 68.6 (Pa) 59 (standard sound pressure 0.0002 µbar) 196.0(external static pressure(Pa)) Audibility limits of continous white level Octave band center frequency (Hz) 137.2 (Pa) 196.0 (Pa) Overall level A 36 40 44 C 49 53.5 57 (dB) (standard sound pressure 0.0002 µbar) 196.0(external static pressure(Pa)) Audibility limits of continous white level Octave band center frequency (Hz) (dB) (dB) 14 152 137.2 (Pa) 196.0 (Pa) Overall level A 36 40 44 C 47 51 54 (dB) (standard sound pressure 0.0002 µbar) 196.0(external static pressure(Pa)) Audibility limits of continous white level Octave band center frequency (Hz) Outside still pressure 68.6 (Pa) Octave band sound pressure level (dB) Octave band sound pressure level (dB) Outside still pressure 68.6 (Pa) 137.2 (Pa) 196.0 (Pa) Overall level A 36 40 44 C 47 51 54 (dB) (standard sound pressure 0.0002 µbar) 196.0(external static pressure(Pa)) Audibility limits of continous white level Octave band center frequency (Hz) Sound level data (NC CURVE) Sound level values shown are based on a measurement in a non resound room. MMD-AP0721H (60Hz) 69 (Pa) 137 (Pa) 196 (Pa) Outside still pressure 69 (Pa) 137 (Pa) 196 (Pa) Overall level A 48 49 50.5 Overall level A 48 49 50.5 54 55 57 55 50 58 C (dB) Octave band sound pressure level (dB) (dB) Octave band sound pressure level (dB) (50Hz) Outside still pressure Audibility limits of continous white level C Audibility limits of continous white level Octave band center frequency (Hz) Octave band center frequency (Hz) MMD-AP0961H (50Hz) 69 (Pa) 137 (Pa) 196 (Pa) Outside still pressure 69 (Pa) 137 (Pa) 196 (Pa) Overall level A 49 50 51.5 Overall level A 49 50 51.5 56 59 61 57 59 61 C Audibility limits of continous white level Octave band center frequency (Hz) (dB) Octave band sound pressure level (dB) (dB) Octave band sound pressure level (dB) (60Hz) Outside still pressure C 14 Audibility limits of continous white level Octave band center frequency (Hz) 153 Sound level data (NC CURVE) Sound level values shown are based on a measurement in a non resound room. MMC-AP0151H Fan Tap H M L Sound pressure level(dB(A)) 35 32 30 Octave band sound pressure level (dB) 90 Microphone H M L 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 10 Audibility limits of continous white sound NC-20 ~ 75 ~ 150 ~ 300 ~ 600 ~ 1200 ~ 2400 ~ 4800 75 150 300 600 1200 2400 4800 9600 ~ 20 Octave band frequency (Hz) MMC-AP0181H MMC-AP0241H,AP0271H Fan Tap H M L Fan Tap H M L Sound pressure level(dB(A)) 36 33 30 Sound pressure level(dB(A)) 38 36 33 90 H M L 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of continous white sound 10 NC-20 Octave band sound pressure level (dB) Octave band sound pressure level (dB) 90 H M L 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of continous white sound 10 ~ 75 ~ 150 ~ 300 ~ 600 ~ 1200 ~ 2400 ~ 4800 ~ 20 ~ 75 ~ 150 ~ 300 ~ 600 ~ 1200 ~ 2400 ~ 4800 75 150 300 600 1200 2400 4800 9600 75 150 300 600 1200 2400 4800 9600 Octave band frequency (Hz) MMC-AP0361H MMC-AP0481H Fan Tap H M L Fan Tap H M L Sound pressure level(dB(A)) 41 38 35 Sound pressure level(dB(A)) 43 40 37 90 H M L 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of continous white sound NC-20 H M L 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of continous white sound 10 NC-20 ~ 75 ~ 150 ~ 300 ~ 600 ~ 1200 ~ 2400 ~ 4800 ~ 20 ~ 75 ~ 150 ~ 300 ~ 600 ~ 1200 ~ 2400 ~ 4800 75 150 300 600 1200 2400 4800 9600 75 150 300 600 1200 2400 4800 9600 Octave band frequency (Hz) ~ 20 Octave band frequency (Hz) 154 Octave band sound pressure level (dB) Octave band sound pressure level (dB) 90 10 ~ 20 Octave band frequency (Hz) 14 NC-20 Sound level data (NC CURVE) MMK-AP0071H, AP0091H, AP0121H Fan Tap Sound pressure level(dB(A)) H M L 39 34 31 Octave band sound pressure level (dB) 90 Microphone 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 M M 30 Audibility limits of continous white level 20 NC-30 L NC-20 10 60 125 250 500 1000 2000 4000 8000 Octave band frequency (Hz) MMK-AP0151H, AP0181H Fan Tap Sound pressure level(dB(A)) MMK-AP0241H H M L 42 38 35 Fan Tap Sound pressure level(dB(A)) M L 38 35 90 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 H M 30 NC-30 L Audibility limits of continous white level 20 NC-20 10 Octave band sound pressure level (dB) 90 Octave band sound pressure level (dB) H 42 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 H M 30 NC-30 L Audibility limits of continous white level 20 NC-20 10 63 125 250 500 1000 2000 Octave band frequency (Hz) 4000 8000 63 125 250 500 1000 2000 4000 8000 14 Octave band frequency (Hz) 155 Sound level data (NC CURVE) Sound level values shown are based on a measurement in a non resound room. Microphone MML-AP0071BH, AP0091BH, AP0121BH 50Hz H M L 60Hz Fan Tap A 36.0 34.0 32.0 Overall level A 36.0 34.0 32.0 41.7 40.2 37.9 (dB) C 41.6 39.8 38.1 (standard sound pressure 0.0002 µbar) Audibility limits of continous white level Fan Tap (standard sound pressure 0.0002 µbar) Audibility limits of continous white level Octave band center frequency (Hz) 50Hz H M L 60Hz Fan Tap H M L Overall level A 36.0 34.0 32.0 Overall level A 36.0 34.0 32.0 (dB) C 41.4 40.0 38.8 (dB) C 41.4 40.0 39.0 (standard sound pressure 0.0002 µbar) Audibility limits of continous white level Octave band center frequency (Hz) Octave band sound pressure level (dB) Octave band sound pressure level (dB) L C MML-AP0151BH, AP0181BH 156 M (dB) Octave band center frequency (Hz) 14 H Overall level Octave band sound pressure level (dB) Octave band sound pressure level (dB) Fan Tap (standard sound pressure 0.0002 µbar) Audibility limits of continous white level Octave band center frequency (Hz) MML-AP0241BH 50Hz Fan Tap H M L 60Hz Fan Tap M L Overall level A 42.0 37.0 33.0 Overall level A 42.0 37.0 33.0 (dB) C 46.4 41.0 37.7 (dB) C 46.6 41.0 38.0 (standard sound pressure 0.0002 µbar) Audibility limits of continous white level Octave band center frequency (Hz) (standard sound pressure 0.0002 µbar) Octave band sound pressure level (dB) Octave band sound pressure level (dB) H Audibility limits of continous white level Octave band center frequency (Hz) 14 157 Sound level data (NC CURVE) Sound level values shown are based on a measurement in a non resound room. MMY-MAP0501HT8, MAP0501HT7, MAP0501T8 Octave band sound pressure level(dB) Sound pressure Level (dB(A)) Microphone 55 90 Cooling Heating 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of continous white sound 10 20~75 75~150 150~300 NC-20 300~600 600~1200 1200~2400 2400~4800 4800~10000 Octave band frequency(Hz) MMY-MAP0601HT8, MAP0601HT7, MAP0601T8 56 Sound pressure Level (dB(A)) 90 Cooling Heating 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of continous white sound 10 20~75 75~150 150~300 Octave band sound pressure level(dB) Octave band sound pressure level(dB) Sound pressure Level (dB(A)) MMY-MAP0801HT8, MAP0801HT7, MAP0801T8 90 Cooling Heating 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of continous white sound NC-20 300~600 600~1200 1200~2400 10 20~75 2400~4800 4800~10000 75~150 Octave band frequency(Hz) 58 Cooling Heating 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of continous white sound 75~150 150~300 NC-20 300~600 600~1200 1200~2400 2400~4800 4800~10000 Octave band frequency(Hz) 158 600~1200 Sound pressure Level (dB(A)) 90 10 20~75 NC-20 300~600 1200~2400 2400~4800 4800~10000 MMY-MAP1201HT8, MAP1201HT7, MAP1201T8 Octave band sound pressure level(dB) Octave band sound pressure level(dB) 14 150~300 Octave band frequency(Hz) MMY-MAP1001HT8, MAP1001HT7, MAP1001T8 Sound pressure Level (dB(A)) 57 59 90 Cooling Heating 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of continous white sound 10 20~75 75~150 150~300 NC-20 300~600 600~1200 1200~2400 2400~4800 4800~10000 Octave band frequency(Hz) Sound level data (NC CURVE) Sound level values shown are based on a measurement in a non resound room. MMY-AP1401HT8, AP1401HT7, AP1401T8 59.5 Sound pressure Level (dB(A)) 90 Cooling Heating 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of continous white sound 10 20~75 75~150 150~300 NC-20 300~600 600~1200 1200~2400 Octave band sound pressure level(dB) Octave band sound pressure level(dB) Sound pressure Level (dB(A)) MMY-AP1601HT8, AP1601HT7, AP1601T8 Octave band frequency(Hz) 80 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of continous white sound 75~150 150~300 Octave band sound pressure level(dB) Octave band sound pressure level(dB) Heating 10 20~75 70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of continous white sound 600~1200 1200~2400 75~150 80 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 150~300 NC-20 300~600 600~1200 1200~2400 2400~4800 4800~10000 Octave band frequency(Hz) Octave band sound pressure level(dB) Octave band sound pressure level(dB) Heating 75~150 61 Heating 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of continous white sound 75~150 150~300 NC-20 300~600 600~1200 Sound pressure Level (dB(A)) 61.5 Audibility limits of continous white sound 2400~4800 4800~10000 1200~2400 2400~4800 4800~10000 MMY-AP2211HT8, AP2211HT7, AP2211T8 Cooling 10 20~75 1200~2400 Octave band frequency(Hz) MMY-AP2201HT8, AP2201HT7, AP2201T8 70 600~1200 80 10 20~75 2400~4800 4800~10000 90 NC-20 300~600 Cooling Octave band frequency(Hz) Sound pressure Level (dB(A)) 150~300 90 NC-20 300~600 NC-70 Sound pressure Level (dB(A)) Cooling 70 Heating 80 MMY-AP2001HT8, AP2001HT7, AP2001T8 60.5 90 Cooling Octave band frequency(Hz) MMY-AP1801HT8, AP1801HT7, MAP1801T8 Sound pressure Level (dB(A)) 90 10 20~75 2400~4800 4800~10000 60 61.5 90 Cooling Heating 80 70 NC-70 14 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of continous white sound 10 20~75 75~150 150~300 NC-20 300~600 600~1200 1200~2400 2400~4800 4800~10000 Octave band frequency(Hz) 159 Sound level data (NC CURVE) Sound level values shown are based on a measurement in a non resound room. MMY-AP2401HT8, AP2401HT7, AP2401T8 62 Sound pressure Level (dB(A)) 90 Cooling Heating 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of continous white sound 10 20~75 75~150 150~300 Octave band sound pressure level(dB) Octave band sound pressure level(dB) Sound pressure Level (dB(A)) MMY-AP2411HT8, AP2411HT7, AP2411T8 90 600~1200 1200~2400 Cooling Heating 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of continous white sound NC-20 300~600 10 20~75 2400~4800 4800~10000 75~150 Octave band frequency(Hz) 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of continous white sound NC-20 300~600 600~1200 1200~2400 2400~4800 4800~10000 Octave band frequency(Hz) Octave band sound pressure level(dB) 14 63 90 Cooling Heating 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of continous white sound 10 20~75 75~150 150~300 NC-20 300~600 600~1200 1200~2400 2400~4800 4800~10000 Octave band frequency(Hz) 160 1200~2400 2400~4800 4800~10000 62.5 90 Cooling Heating 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of continous white sound 10 20~75 75~150 150~300 NC-20 300~600 600~1200 1200~2400 2400~4800 4800~10000 Octave band frequency(Hz) MMY-AP3001HT8, AP3001HT7, AP3001T8 Sound pressure Level (dB(A)) Octave band sound pressure level(dB) Octave band sound pressure level(dB) Heating 150~300 600~1200 Sound pressure Level (dB(A)) Cooling 75~150 NC-20 300~600 MMY-AP2801HT8, AP2801HT7, AP2801T8 62 90 10 20~75 150~300 Octave band frequency(Hz) MMY-AP2601HT8, AP2601HT7, AP2601T8 Sound pressure Level (dB(A)) 62 Sound level data (NC CURVE) Sound level values shown are based on a measurement in a non resound room. MMY-AP3201HT8, AP3201HT7, AP3201T8 63 Sound pressure Level (dB(A)) 90 Cooling Heating 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of continous white sound 10 20~75 75~150 150~300 Octave band sound pressure level(dB) Octave band sound pressure level(dB) Sound pressure Level (dB(A)) MMY-AP3211HT8, AP3211HT7, AP3211T8 90 600~1200 1200~2400 Cooling Heating 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of continous white sound NC-20 300~600 10 20~75 2400~4800 4800~10000 63 75~150 150~300 NC-20 300~600 600~1200 1200~2400 2400~4800 4800~10000 Octave band frequency(Hz) Octave band frequency(Hz) MMY-AP3401HT8, AP3401HT7, AP3401T8 MMY-AP3411HT8, AP3411HT7, AP3411T8 63.5 90 Sound pressure Level (dB(A)) Cooling Heating 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of continous white sound 10 20~75 75~150 150~300 Octave band sound pressure level(dB) Octave band sound pressure level(dB) Sound pressure Level (dB(A)) 90 600~1200 1200~2400 Cooling Heating 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of continous white sound NC-20 300~600 10 20~75 2400~4800 4800~10000 63.5 75~150 150~300 NC-20 300~600 600~1200 1200~2400 2400~4800 4800~10000 Octave band frequency(Hz) Octave band frequency(Hz) MMY-AP3601HT8, AP3601HT7, AP3601T8 MMY-AP3611HT8, AP3611HT7, AP3611T8 63.5 90 Sound pressure Level (dB(A)) Cooling Heating 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of continous white sound 10 20~75 75~150 150~300 NC-20 300~600 600~1200 1200~2400 2400~4800 4800~10000 Octave band frequency(Hz) Octave band sound pressure level(dB) Octave band sound pressure level(dB) Sound pressure Level (dB(A)) 64 90 Cooling Heating 80 70 NC-70 14 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of continous white sound 10 20~75 75~150 150~300 NC-20 300~600 600~1200 1200~2400 2400~4800 4800~10000 Octave band frequency(Hz) 161 Sound level data (NC CURVE) Sound level values shown are based on a measurement in a non resound room. MMY-AP3801HT8, AP3801HT7, AP3801T8 64 Sound pressure Level (dB(A)) 90 Cooling Heating 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of continous white sound 10 20~75 75~150 150~300 Octave band sound pressure level(dB) Octave band sound pressure level(dB) Sound pressure Level (dB(A)) MMY-AP4001HT8, AP4001HT7, AP4001T8 90 600~1200 1200~2400 Cooling Heating 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of continous white sound NC-20 300~600 10 20~75 2400~4800 4800~10000 75~150 NC-20 300~600 600~1200 1200~2400 2400~4800 4800~10000 Octave band frequency(Hz) MMY-AP4201HT8, AP4201HT7, AP4201T8 MMY-AP4401HT8, AP4401HT7, AP4401T8 Sound pressure Level (dB(A)) Octave band sound pressure level(dB) Cooling Heating 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of continous white sound 10 20~75 75~150 150~300 Octave band sound pressure level(dB) 64.5 90 NC-20 300~600 600~1200 1200~2400 Cooling Heating 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of continous white sound 10 20~75 75~150 2400~4800 4800~10000 MMY-AP4601HT8, AP4601HT7, AP4601T8 Heating 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of continous white sound 150~300 NC-20 300~600 600~1200 1200~2400 600~1200 Sound pressure Level (dB(A)) Cooling 75~150 NC-20 300~600 2400~4800 4800~10000 Octave band frequency(Hz) 1200~2400 2400~4800 4800~10000 MMY-AP4801HT8, AP4801HT7, AP4801T8 65 90 10 20~75 150~300 Octave band frequency(Hz) Octave band sound pressure level(dB) Octave band sound pressure level(dB) Sound pressure Level (dB(A)) 64.5 90 Octave band frequency(Hz) 162 150~300 Octave band frequency(Hz) Sound pressure Level (dB(A)) 14 64 65 90 Cooling Heating 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Audibility limits of continous white sound 10 20~75 75~150 150~300 NC-20 300~600 600~1200 1200~2400 2400~4800 4800~10000 Octave band frequency(Hz) 15 Dimensional drawing 163 Foreword 164 15 Dimensional drawing Foreword Indoor unit 4-way Air Discharge Cassette Type MMU-AP0091H to P0561H 860 to 910 ceiling open dimension 254.5 346.5 790 hanging bolt pitch 950 panel external dimension 415 Suction grille (Air suction port) Electric parts box Air discharge port (4-way) o 35.. 381.6 723 hanging bolt pitch Z 860 to 910 ceiling open dimension 950 panel external dimension For branch duct knockout square hole O/ 150 (2 positions at right side) Refrigerant pipe connecting port 840 (Gas) 250 70 Refrigerant pipe Drain discharge port 270 connecting port 105 (Liquid) 45 113 174 Model AP0091H to AP0301H AP0361H to AP0561H Bottom face of ceiling 15 or more Stand-up 850 or less Indoor unit Bottom face of ceiling (NOTE) As ABS is used for the drain discharge port of the main unit, the vinyl chloride paste cannot be used. Use the flexible hose (Band fix) included in the package. 64 Knockout for flesh air intake For O / 100 Z view Drain-up standing-up size 120 2.7 Wired remote controller RBC-AMT21E RBC-AMT31E 4 Simple wired remote controller RBC-AS21E RBC-AS21E2 Wireless remote controller kit TCB-AX21U(W)-E TCB-AX21U(W)-E2 16 120 Weekly timer application RBC-AMT31E and RBC-EXW21E2 1000 or more A 250 319 mm B 120 183 1000 or more 1000 or more Bottom face of ceiling 57 8 .5 57 5 2 18 Stand-up 640 or less 360 15 or more Bottom face of ceiling 30 Space required for installation and servicing 200 Check port ( 450) Check port ( 450) 200 88 130 210 A 97 B 35 840 480 227 105 Hanging bolt M10 or W3/8 local arrange 15 165 2-way Air Discharge Cassette Type MMU-AP0071WH, AP0091WH, AP0121WH Z view Center of panel Center of main unit Air discharge port (2-way) 1000 Electric parts box 95 650 Hanging bolt pitch 480 Unit external dimension 550 Ceiling open dimension 620 Panel external dimension 650 35 Air discharge port (2-way) 30 Unit external dimension 830 Hanging bolt pitch 880 Ceiling open dimension 960 Panel external dimension 1000 156 398 1000 or more 1000 or more Ceiling panel (Procured by locally) Indoor unit Bottom face of ceiling 166 Wired remote controller RBC-AMT21E RBC-AMT31E Simple wired remote controller RBC-AS21E RBC-AS21E2 Wireless remote controller kit TCB-AX21E TCB-AX21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 Z Bottom face of ceiling Branch duct knockout hole (Also on opposite side) Refrigerant pipe connecting port (Gas side O / 9.5) 100 Refrigerant pipe connecting port (Liquid side O / 6.4) 35 Drain pipe connecting port Inner O / 32, Nominal O/ 25 for vinyl chloride pipe 56 75 55 Pour water port O / 150 78 508mm or less 100mm or less 160mm or less Space required for installation and servicing 60 210 Power supply connecting port 35 178 242 282 348 Obstruction 00 O/ 2 8 1000 or more 222 Ceiling 15 Hanging bolt 4-M10 procured locally 265 53 5mm or more Knockout hole for taking-in air (Only at reverse side) Foreword MMU-AP0151WH, AP0181WH, AP0241WH, AP0271WH, AP0301WH Z view Center of main unit Center of panel Air discharge port (2-way) Electric parts box Air suction port (2-way) 650 Hanging bolt pitch 480 Unit external dimension 550 Ceiling open imension 620 Panel external dimension 650 95 35 30 Unit external dimension 1350 Hanging bolt pitch 1400 Ceiling open dimension 1480 Panel external dimension 1520 Obstruction 1000 or more 1000 or more Space required for installation and servicing 222 156 Ceiling 60 8 398 5mm or more 1000 or more 0 ¯ 20 53 Hanging bolt 4-M10 procured locally 295 Ceiling panel (Procured locally) Bottom face of ceiling Z 508mm or less Bottom face of ceiling Drain pipe connecting port Inner O / 3̄2, Nominal O/ 25 for vinyl chloride pipe 75 55 Pour water port Refrigerant pipe connecting port (Gas side O / B) 56 Refrigerant pipe connecting port 100 (Liquid side OA) / 35 ¯ 150 78 Wired remote controller RBC-AMT21E RBC-AMT31E Simple wired remote controller RBC-AS21E RBC-AS21E2 Wireless remote controller kit TCB-AX21E TCB-AX21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 210 Power supply connecting port 35 178 242 282 348 100mm or less 160mm or less Branch duct knockout hole (Also on opposite side) Knockout hole for taking-in air (Only at reverse side) B Model A MMU-AP0151WH to AP0181WH O / 6.4 O/ 12.7 MMU-AP0241WH to AP0301WH O / 9.5 O/ 15.9 15 167 MMU-AP0481WH Z view Center of panel Center of main unit Air suction port (2-way) 680 Ceiling open dimension 650 Panel external dimension 680 Hanging bolt pitch 510 Unit external dimension 620 5 95 Air discharge port (2-way) 1898 Electric parts box 105 Unit external dimension 1650 Hanging bolt pitch 1700 Ceiling open dimension 1850 Panel external dimension 1898 1000 Obstruction or more 1000 or more Space required for installation and servicing 68 ¯2 00 ¯2 00 230 166 Ceiling 60 8 406 5mm or more 1000 or more Hanging bolt 4-M10 procured locally 150 455 Ceiling panel (Procured locally) Z Bottom face of ceiling 15 Drain pipe connecting port (VP25) 75 55 Pour water port 50 ¯1 15 186 250 290 356 Bottom face of ceiling Refrigerant pipe connecting port (Gas side O / 15.9) Refrigerant pipe 56 connecting port 100 (Liquid side O / 9.5) 86 516mm or less 100mm or less 160mm or less Branch duct knockout hole (Also on reverse side) 4 168 Wired remote controller RBC-AMT21E RBC-AMT31E Simple wired remote controller RBC-AS21E RBC-AS21E2 Wireless remote controller kit TCB-AX21E 16 120 TCB-AX21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 120 15 2.7 210 Power supply Knockout hole for taking-in air connecting port (Only at reverse side) 1-way Air Discharge Cassette Type MMU-AP0071YH, AP0091YH, AP0121YH Panel external dimension 1050 Drain pipe connecting port (VP25) 20 Power supply connecting port Panel external dimension 470 Ceiling open dimension 430 20 Ceiling open dimension 1010 Center of panel Hanging bolt 4-M10 procured locally Support metal Refrigerant pipe connecting port (Gas side) 9.5 Discharge louver Refrigerant pipe connecting port (Liquid side) 6.4 Ceiling panel Procured by locally Air discharge port Bottom face of ceiling Panel mounting hole 5 positions Air suction port Dimensions Model MMU- A B C AP0071YH, AP0091YH, AP0121YH 235 245 200 B or more 120 2.7 Wired remote controller 4 RBC-AMT21E RBC-AMT31E Simple wired remote controller RBC-AS21E RBC-AS21E2 Wireless remote controller kit TCB-AX21E 100 or more 100 or more 200 or more TCB-AX21E2 Weekly timer application 120 16 RBC-AMT31E and RBC-EXW21E2 Space required for installation and servicing 15 169 MMU-AP0151SH, AP0181SH, AP0241SH 150 knockout hole (For air intake) 18 96 0 Panel external dimension A Ceiling open dimension B Center of panel Pitch 200 N 20 110 10 H 755 Air discharge port Power supply connecting port 10 130 100 100 Z view 440 335 255 160 120 100 10 F Z 198 E 80 80 60 50 A 125 530 655 D 30 C 65 Suction port 30 Ceiling open dimension 695 Panel external dimension 755 30 30 20 G 100 Refrigerant pipe connecting port (Liquid side) I Knockout hole for discharge forward Refrigerant pipe connecting port (Gas side) J Drain pipe connecting port (VP25) Z Dimensions A B C D E F G AP0151SH, AP0181SH 1220 1160 545 485 530 470 AP0241SH 1420 1360 645 585 630 570 200 or more Model MMU- 170 I J N 254 800 6.4 12.7 4 460 1000 9.5 15.9 5 Wired remote controller 1000 or more 1000 or more 4 Ceiling RBC-AMT21E Obstacle RBC-AMT31E Simple wired remote controller Space required for installation and servicing RBC-AS21E RBC-AS21E2 Wireless remote controller kit TCB-AX21E TCB-AX21E2 Weekly timer application 120 16 RBC-AMT31E and RBC-EXW21E2 120 2.7 15 1000 or more H Concealed Duct Standard Type MMD-AP0071BH, AP0091BH, AP0121BH, AP0151BH, AP0181BH, AP0241BH, AP0271BH, AP0301BH, AP0361BH, AP0481BH, AP0561BH Drain pipe connecting port (Inner O / 32 vinyl chloride pipe VP25 connection) Unit external dimension 40 800 Hanging bolt pitch 700 59 25 41 Hanging bolt pitch A 7.5 50 638 498 393 B 41 Refrigerant pipe connecting port (Gas side O/ F) 215 44 49 70 to 270 10-O / 4 tapping screw O / 160 142 C 131 50 knockout hole (For air intake) (When attaching directly) O / 125 91 150 Air Discharge Refrigerant pipe connecting port (Liquid side O/ G) 50 243 Hanging bolt 4-M10 (Procured locally) O / 26 power supply, remote controller wires drawing-out port 196 Air Suction Panel C, L Ceiling opening 470 240 Ceiling open dimension D E Air Suction Model MMD- AP0071BH, AP0091BH, AP0121BH AP0151BH, AP0181BH AP0241BH, AP0271BH, AP0301BH AP0361BH, AP0481BH, AP0561BH A 616 766 1066 1416 B 550 700 1000 1350 C 350 500 800 1150 (Note) Two of f high efficiency filters available. Deodorant filter not available. (Note) Be sure to create a check port at position A as indicated in the following figure. This is for maintenance of the equipment. Air outlet Ceiling opening part D 600 750 1050 1400 E 470 620 920 1270 F 9.5 12.7 15.9 15.9 G 6.4 9.4 9.5 9.5 Wired remote controller RBC-AMT21E RBC-AMT31E Simple wired remote controller RBC-AS21E RBC-AS21E2 Wireless remote controller kit TCB-AX21E TCB-AX21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 Check port B 450mm Air filter 700mm for maintenance of air filter 271mm or less 300mm Check port A 450mm 550mm or less (150mm) 15 100mm or less Drain-up piping 700mm for maintenance of air filter 171 Concealed Duct High Static Pressure Type MMD-AP0181H, AP0241H, AP0271H, AP0361H, AP0481H, AP0721H, AP0961H MMD-AP0181H to AP0361H MMD-AP0481H 710 (Hanging bolt mounting pitch 800) Hole for hanging bolt (4-O/ 12 x 72) Power supply/ communication piping port (O/ 26) (Under electric parts box) Electric parts box Hole for hanging bolt (4-O/ 12 x 72) Power supply/ communication piping port (O/ 26) (Under electric parts box) Refrigerant pipe connecting port (Liquid side O/ A) Refrigerant pipe connecting port (Gas side O/ B) Electric parts box Refrigerant pipe connecting port (Liquid side O/ 9.5) Refrigerant pipe connecting port (Gas side O/ 15.9) Screw hole for duct mounting (6-M6) Air suction port Drain pipe connecting port (VP25) Screw hole for duct mounting (8-M6) Air suction port Drain pipe connectingport (VP25) Z view Z view Air discharge port Screw hole for duct mounting (8-M6) Air discharge port Screw hole for duct mounting (6-M6) AP0181H to AP0271H type AP0361H type Model MMDAP0181H AP0241H, AP0271H, AP0361H, AP0481H A 6.4 9.5 B 12.7 15.9 Space required for installation and servicing *1 Service space Service space 1288 (Hanging bolt mounting pitch) 1328 Refrigerant pipe connecting port (Gas side O/ A) 65 370 Drain pipe connecting port (VP25) Model MMD- Gas pipe O/ A AP0721H O / 22.2 AP0961H O / 22.2 120 Screw hole for duct Suction port mounting (10-M6) 250 250 250 250 190 Wired remote controller RBC-AMT21E RBC-AMT31E Simple wired4remote controller RBC-AS21E RBC-AS21E2 Wireless remote controller kit TCB-AX21E TCB-AX21E2 Weekly timer application 120and RBC-EXW21E2 16 RBC-AMT31E 2.7 35 470 31 624 698 406 190 250 250 250 250 200 150 45 1380 Refrigerant pipe connecting port (Liquid side O/ 12.7) Discharge port Screw hole for duct mounting (10-M6) 172 *1 Service space requirement for MMD-AP0721H and AP0961H are different from those in the above figure. For details make enquiries to your dealer. Electric parts box 1250 15 Check port 600 100 1260 (Hanging bolt mounting pitch) MMD-AP0721H, AP0961H Long hole for hanging bolt (4-O/ 12 92) Air discharge port 500 mm or more Screw hole for duct mounting (4-M6) 600 mm or more Z view Under Ceiling Type MMC-AP0151H, AP0181H, AP0241H, AP0271H, AP0361H, AP0481H Upper piping drawing-out port (Knockout) 70 Piping drawing-out port (Knockout port) Drain port VP20 (Inner diam. O / 26, hose supplied) Left drain size Drain pipe connecting port B (Hanging position) Refrigerant pipe (Liquid side O / D) Refrigerant pipe (Gas side O / C) Model MMC- A A B C D AP0151H, AP0181H 910 855 12.7 6.4 AP0241H to AP0271H 1180 1125 15.9 9.5 AP0361H, AP0481H 1595 1540 15.9 9.5 Wireless sensor mounting section (Optional) Ceiling surface Unit 250 or more 250 or more (Front side to be positioned horizontally.) 500 or more Within 50 Hanging bolt Space required for installation and servicing Remote controller cable taking-in port Wired remote controller Power supply taking-in port RBC-AMT21E (Knockout hole) RBC-AMT31E 4 Remote controller cable taking-in port (Knockout) Simple wired remote controller RBC-AS21E RBC-AS21E2 Wireless remote controller kit RBC-AX22CE Air taking-in port RBC-AX22CE2 (Duct sold separately) (Knockout hole O / 92) Weekly timer application Drain left piping drawing-out port Piping hole on the wall 120 (Knockout) (O / 100 hole) 16 RBC-AMT31E and RBC-EXW21E2 120 2.7 320 170 (Hanging position) Power supply cable taking-in port (Knockout) Remote controller piping taking-in port (Knockout hole) 15 173 High Wall Type MMK-AP0071H, AP0091H, AP0121H Position of holes on the installation plate. Long hole for wooden screw 15-6 x 30 690 (Installation plate) Hole for anchor bolt 10-10 x 20 long hole (Including installation plate) 210 Including installation plate (Accessory) Earth screw (M4) (Inside of electric parts box) Upper end of installation plate Refrigerant pipe connecting port O Gas side 9.5 / 9.5 Drain pipe connecting port Air suction port Discharge port (Air direction upward/downward/leftward/rightward are adjustable.) Piping port from left/right sides (Knockout) 30 or more Gas pipe 440 Liquid pipe 540 Drain pipe 560 At shipment (When drawing pipe from left) 300 or more 300 or more Space required for service Wired remote controller RBC-AMT21E RBC-AMT31E 4 Simple wired remote controller RBC-AS21E RBC-AS21E2 Wireless remote controller kit TCB-AX21E TCB-AX21E2 Weekly timer application 120 16 RBC-AMT31E and RBC-EXW21E2 174 120 2.7 15 Refrigerant pipe connecting port Liquid side O/ 6.4 MMK-AP0151H, AP0181H Position of holes on the installation plate 182.5 690 (Installation plate) hole for wooden screw 15-6 x 30 182.5 Hole for anchor bolt 10-10 x 20 long hole Upper end of installation plate (Including installation plate) 210 Including installation plate (Accessory) Earth screw (M4) (Inside of electric parts box) Refrigerant pipe Refrigerant pipe connecting port connecting port Liquid side O/ 6.4 Gas side O/ 12.7 Air suction port Air discharge port (Air direction upward/downward/leftward/rightward is adjustable.) Drain pipe connecting port Piping port from left/right sides (Knockout) 30 or more Gas pipe 440 Liquid pipe 540 Drain pipe 560 At shipment (When drawing pipe from left) Wired remote controller RBC-AMT21E 300 or more 300 or more RBC-AMT31E Space required for service Simple wired remote controller RBC-AS21E RBC-AS21E2 Wireless remote controller kit TCB-AX21E TCB-AX21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 15 175 MMK-AP0241H Position of holes on the installation plate hole for wooden screw 21-6 x 30 170 1090 (Installation plate) Hole for anchor bolt 16-10 x 20 long hole 170 (Including installation plate) 210 Including installation plate (Accessory) Earth screw (M4) (Inside of electric parts box) Upper end of installation plate Refrigerant pipe connecting port Gas side O/ 15.9 Air discharge port (Air direction upward/ Air suction port downward/leftward/rightward are adjustable.) Drain pipe connecting port Piping port from left/right sides (Knockout) 30 or more Gas pipe 440 Liquid pipe 540 Drain pipe 560 At shipment (When drawing pipe from left) 300 or more 15 176 Refrigerant pipe connecting port Liquid side O/ 9.5 300 or more Wired remote controller Space required for service RBC-AMT21E RBC-AMT31E Simple wired remote controller RBC-AS21E RBC-AS21E2 Wireless remote controller kit TCB-AX21E TCB-AX21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 Floor Standing Cabinet Type MML-AP0071H, AP0091H, AP0121H, AP0151H, AP0181H, AP0241H Lower refrigerant piping port (50 x 100 knockout hole) 130 Fixing hole (Floor) (2-O/ 10) Operation switch section (Sold separately) Fixing hole (Floor) (Two off knockout holes O/ 10-O/ 20) Air discharge port Hole fixing wall (2-10 x 24 long hole) Air suction port Refrigerant pipe port (50 x 100 knockout hole) ( left100 side ) Power supply cord hole (O/ 26 knockout on both sides) Dimensions Model MMC- A B AP0071H, AP0091H, AP0121H O / 9.5 O / 6.4 AP0151H, AP0181H O / 12.7 O / 6.4 AP0241H O / 15.9 O / 9.5 Earth screw (M6) Refrigerant pipe port (O/ 130 knockout hole) Wired remote controller RBC-AMT21E RBC-AMT31E Simple wired remote controller RBC-AS21E RBC-AS21E2 Wireless remote controller kit TCB-AX21E TCB-AX21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 Refrigerant pipe connecting port (Liquid side O/ B) Refrigerant pipe connecting port (Gas side O/ A) Drain pipe connecting port (O/ 20) Space required for service Figure shows piping at the left side Positional drawing of piping 500 (Front side) or more 15 300 or more 1000 or more Wall Wall (Front side) 177 Floor Standing Concealed Type MML-AP0071BH, AP0091BH, AP0121BH, AP0151BH, AP0181BH, AP0241BH Fixing hole (Floor) (Discharge port size in flange) Ceiling board section 150 or more (Service space) 150 or more (Air discharge port size in flange) (Service space) 2-O/ 4.7 hole (Left/right side each) Expansion valve box G-O/ 4.7 hole (Front side and rear side each) 4-O/ 15 hole (For mounting rear side) 2-12 x 18 hole Fixing hole (floor) Name Pipe connecting port at liquid side (O/ E) Dimensions Pipe connecting port at gas side (O/ F) Electric parts box (Earth terminal is on the inside) Air filter Model MMLAP0151BH, AP0181BH AP0241BH 4 15 178 A AP0071BH, AP0091BH, AP0121BH B C D 610 580 550 4 910 880 850 7 Wired remote controller RBC-AMT21E RBC-AMT31E Simple wired remote controller RBC-AS21E RBC-AS21E2 120 16 Weekly timer application RBC-AMT31E and RBC-EXW21E2 120 Drain pipe connecting port (20A) 2.7 No. E 6.4 9.5 F G 9.5 5 12.7 15.9 8 Floor Standing Type MMF-AP0151H, AP0181H, AP0241H, AP0271H Wall of installing distance ( Incase ) is 50mm from wall Dimensions Model Lower refrigerant piping port (50 x 120 Knockout hole) Installation plate Discharge port A B MMF-AP0151H, AP0181H O/ 12.7 O / 6.4 MMF-AP0241H, AP0271H O/ 15.7 O / 9.5 600 30 x 3 30 x 3 80 Wall Wall a b Wall Control part More Front than 500 Front More than 1000 Wall More than 200 Space required for service (In case of right side piping ) Control cover Wall Floor Refrigerant piping port (Both side) (O/ 80 Knockout) Earth screw (M4) Drain hose Installation plate Suction port Refrigerant piping hole (Back side) (O/ 130 Knockout) Refrigerant piping hole (Bottom side) (50 x 120 Knockout) Refrigerant piping position Refrigerant piping joint (Gas side A) Wired remote controller RBC-AMT21E RBC-AMT31E Simple wired remote controller RBC-AS21E RBC-AS21E2 Wireless remote controller kit TCB-AX21E TCB-AX21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 Refrigerant piping joint (Liquid side B) Details of hole for lower side piping ( ) O / 130 In case b 1773 2- lower hole For M8 Screw bolt or M8 Anchor bolt In case a 1770 Details of hole for back side piping Knockout (For backside piping) 15 4- lower hole M8 Screw bolt ( For or M8 Anchor bolt ) 50 x 120 (Square) (For under surface piping) 179 MMF-AP0361H, AP0481H, AP0561H Wall Incase of installing distance is ( 50mm ) from wall Lower refrigerant piping port (50 x 120 Knockout) Installation plate Discharge port 600 30 x 3 30 x 3 80 Wall Wall a b Wall Control part Control cover More Front than 500 Wall Front More than 1000 Wall More than 200 Space required for service (In case of right side piping ) Floor Refrigerant piping port (Both side) (O / 80 Knockout) Drain hose Installation plate Earth screw (M4) Dtain hose Suction port Refrigerant piping hole (Back side) (O / 130 Knockout) Refrigerant piping hole (Bottom side) (50 x 120 Knockout) Refrigerant piping position Gas side Refrigerant piping joint (Gas side O / 19) Liquid side Wired remote controller RBC-AMT21E RBC-AMT31E Simple wired remote controller RBC-AS21E RBC-AS21E2 Wireless remote controller kit TCB-AX21E TCB-AX21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 Refrigerant piping joint (Liquid side O / 9.5) 2- lower hole M8 Screw bolt ( For or M8 Anchor bolt ) In case b 1773 15 In case a 1770 Details of hole for back side piping O / 130 Knockout (For backside piping) 180 Details of hole for lower side piping 4- lower hole For M8 Screw bolt or M8 Anchor bolt ( ) 50 x 120 (Square) (For under surface piping) Outdoor module (NOTES) 1. If there is an obstacle above the outdoor unit, ensure there is a minimum space of 2000mm or more above the unit. 2. Any obstacle around the perimeter of the outdoor unit must be kept 800mm or less. 3. Draw out the locally supplied piping at the front of the outdoor unit horizontally, keep a minimum of 500mm or more. between the outdoor unit and traversing pipe If the pipework is to be installed in this method. 790 (including steady leg) 755 anchor bolt pitch 750 MMY-MAP0501T8, MAP0601T8, MAP0801T8, MAP1001T8, MAP1201T8 MMY-MAP0501HT8, MAP0601HT8, MAP0801HT8, MAP1001HT8, MAP1201HT8 MMY-MAP0501HT7, MAP0601HT7, MAP0801HT7, MAP1001HT7, MAP1201HT7 700 anchor bolt pitch 4-15 x 20 (Long hole) 990 A 165 Applied model B C MMY-MAP0501T8, MAP0501HT8, MAP0501HT7 O/ 15.9 O/ 9.5 280 MMY-MAP0601T8, MAP0601HT8, MAP0601HT7 O/ 19.1 O/ 9.5 280 MMY-MAP0801T8, MAP0801HT8, MAP0801HT7 O/ 22.2 O/ 12.7 (205) MMY-MAP1001T8, MAP1001HT8, MAP1001HT7 O/ 22.2 O/ 12.7 (205) 1800 1640 MMY-MAP1201T8, MAP1201HT8, MAP1201HT7 O/ 28.6 O/ 12.7 (205) *1 Cutting position of L-shape pipe when pipe 700 Refrigerant pipe connecting port (Gas side) A at gas side is connected (Recommended pipe connecting position) 1750 or more 500 or more * Refrigerant pipe connecting port (Liquid side) B Balance pipe connecting port O / 9.5 Front side (For work and service) 10 or more 10 or more Space required for service Knockout hole for power piping (O / 48) Balance pipe connecting port 115 88 Square hole 64 125 136 140 215 Refrigerant pipe connecting port (Liquid side) 135 88 155 67 55 Front side Front side Front side 800 or less Foundation 700 anchor bolt pitch (Note 3) 600 (1000 or more) 500 600 or more or more or more 630 80 610 Knockout for control piping (O / 27) 100 MMY-MAP0501T8 MMY-MAP0501T8 MMY-MAP0501HT8 MMY-MAP0601HT8 MMY-MAP0601HT7 MMY-MAP0601HT7 Front side Front side 500 or more 755 anchor bolt pitch Foundation C 80 100 Earth-attaching section of bottom plate (Note 3) 500 (1000 or more) 500 600 or more or more or more 500 500 or more 2-60 x 150 square hole (Hole for handling goods) 1 88 241 C 1010 or more 15 20 Refrigerant pipe connecting port (Gas side) 225 230 173 Details of front pipe/cabling holes Details of hole for piping at lower side (Plane view) 52 181 Two units connected MMY-AP1401T8, AP1601T8, AP1801T8, AP2001T8, AP2211T8, AP2411T8 MMY-AP1401HT8, AP1601HT8, AP1801HT8, AP2001HT8, AP2211HT8, AP2411HT8 MMY-AP1401HT7, AP1601HT7, AP1801HT7, AP2001HT7, AP2211HT7, AP2411HT7 (NOTES) 1. If there is an obstacle above the outdoor unit, ensure there is a minimum space of 2000mm or more above the unit. 2. Any obstacle around the perimeter of the outdoor unit must be kept 800mm or less. 3. Draw out the locally supplied piping at the front of the outdoor unit horizontally, keep a minimum of 500mm or more. between the outdoor unit and traversing pipe If the pipework is to be installed in this method. 4. Arrange each of the outdoor units in order of their capacity. _ Follower) (Header > 20 or more 990 750 755 anchor bolt pitch 790 (including steady leg) 990 (310) 700 anchor bolt pitch 2 8-15 x 20 (Long hole) 88 700 1800 1640 165 1 700 anchor bolt pitch 2000 Combination outdoor unit Combination unit Header Follower MMY-AP1401T8, AP1401HT8, AP1401HT7 MMY-MAP0801T8, MAP0801HT8, MAP0801HT7 MMY-MAP0601T8, MAP0601HT8, MAP0601HT7 MMY-AP1601T8, AP1601HT8, AP1601HT7 MMY-MAP0801T8, MAP0801HT8, MAP0801HT7 MMY-MAP0801T8, MAP0801HT8, MAP0801HT7 MMY-AP1801T8, AP1801HT8, AP1801HT7 MMY-MAP1001T8, MAP1001HT8, MAP1001HT7 MMY-MAP0801T8, MAP0801HT8, MAP0801HT7 MMY-AP2001T8, AP2001HT8, AP2001HT7 MMY-MAP1001T8, MAP1001HT8, MAP1001HT7 MMY-MAP1001T8, MAP1001HT8, MAP1001HT7 MMY-AP2211T8, AP2211HT8, AP2211HT7 MMY-MAP1201T8, MAP1201HT8, MAP1201HT7 MMY-MAP1001T8, MAP1001HT8, MAP1001HT7 Front side Front side 1750mm or more (Note 4) 500mm or more 500mm or more (Note 3) (Note 4) (1000 or more) 500 600 or more or more Front side Front side Front side Front side 600 or more Front side Front side Front side Front side 500 or more 15 (Note 4) (Note 3) (Note 4) 500 (1000 or more) 500 or more 600 or more or more MMY-AP2411T8, AP2411HT8, AP2411HT7 MMY-MAP1201T8, MAP1201HT8, MAP1201HT7 MMY-MAP1201T8, MAP1201HT8, MAP1201HT7 10mm or more 20mm or more Front side (For work and service) 182 800 or less 800 or less 2020mm or more Space required for service 10mm or more Three units connected MMY-AP2201T8, AP2401T8, AP2601T8, AP2801T8, AP3001T8, AP3211T8, AP3411T8, AP3611T8 MMY-AP2201HT8, AP2401HT8, AP2601HT8, AP2801HT8, AP3001HT8, AP3211HT8, AP3411HT8, AP3611HT8 MMY-AP2201HT7, AP2401HT7, AP2601HT7, AP2801HT7, AP3001HT7, AP3211HT7, AP3411HT7, AP3611HT7 990 20 or more 990 20 or more 990 750 755 anchor bolt pitch 790 (including steady leg) (NOTES) 1. If there is an obstacle above the outdoor unit, ensure there is a minimum space of 2000mm or more above the unit. 2. Any obstacle around the perimeter of the outdoor unit must be kept 800mm or less. 3. Draw out the locally supplied piping at the front of the outdoor unit horizontally, keep a minimum of 500mm or more. between the outdoor unit and traversing pipe If the pipework is to be installed in this method. 4. Arrange each of the outdoor units in order of their capacity. _ Follower 3 ) _ Follower 2 > (Header > (310) 700 anchor bolt pitch 2 700 anchor bolt pitch 3 12-15 x 20 (Long hole) 88 700 1800 1640 165 1 (310) 700 anchor bolt pitch 3010 Combination outdoor unit Combination unit MMY-MAP0601T8, HT8, HT7 MMY-AP2401T8, HT8, HT7 MMY-MAP0801T8, HT8, HT7 MMY-MAP0801T8, HT8, HT7 MMY-MAP0801T8, HT8, HT7 MMY-AP2601T8, HT8, HT7 MMY-MAP1001T8, HT8, HT7 MMY-MAP0801T8, HT8, HT7 MMY-MAP0801T8, HT8, HT7 MMY-AP2801T8, HT8, HT7 MMY-MAP1001T8, HT8, HT7 MMY-MAP1001T8, HT8, HT7 MMY-MAP0801T8, HT8, HT7 MMY-AP3001T8, HT8, HT7 MMY-MAP1001T8, HT8, HT7 MMY-MAP1001T8, HT8, HT7 MMY-MAP1001T8, HT8, HT7 MMY-AP3221T8, HT8, HT7 MMY-MAP1201T8, HT8, HT7 MMY-MAP1001T8, HT8, HT7 MMY-MAP1001T8, HT8, HT7 MMY-AP3411T8, HT8, HT7 MMY-MAP1201T8, HT8, HT7 MMY-MAP1201T8, HT8, HT7 MMY-MAP1001T8, HT8, HT7 MMY-AP3611T8, HT8, HT7 MMY-MAP1201T8, HT8, HT7 MMY-MAP1201T8, HT8, HT7 MMY-MAP1201T8, HT8, HT7 3030mm or more 1750mm or more 500mm or more Front side (For work and service) (Front side) 500 or more Front side Front side Front side 10mm or more 20mm or more 20mm or more 10mm or more 15 Space required for service 800 or less 800 or less Front side Front side Front side Front side Front side Front side Front side Front side Front side Front side Front side Front side (Rear side) MMY-MAP0801T8, HT8, HT7 (Note 4) 500mm or more Follower MMY-MAP0801T8, HT8, HT7 (Note 3) 600 (1000 or more) (Note 4) or more 600 or more 500 or more Follower MMY-AP2201T8, HT8, HT7 (Note 4) (Note 3) (Note 4) (1000 or more) 500 or more 600 or more 500 or more Header 183 Four units connected MMY-AP3201T8, AP3401T8, AP3601T8, AP3801T8, AP4001T8, AP4201T8, AP4401T8, AP4601T8, AP4801T8 MMY-AP3201HT8, AP3401HT8, AP3601HT8, AP3801HT8, AP4001HT8, AP4201HT8, AP4401HT8, AP4601HT8, AP4801HT8 MMY-AP3201HT7, AP3401HT7, AP3601HT7, AP3801HT7, AP4001HT7, AP4201HT7, AP4401HT7, AP4601HT7, AP4801HT7 20 or more 990 20 or more 20 or more 990 990 750 755 anchor bolt pitch 790 (including steady leg) 990 700 anchor bolt pitch (310) 700 anchor bolt pitch 700 (310) anchor bolt pitch 2 700 anchor bolt pitch 3 16-15 x 20 (Long hole) 4 88 700 1800 1640 165 1 (310) 4020 500mm or more 15 ) (Note 4) (Note 3) (1000 or more) 500 600 600 or more or more or more Follower MMY-MAP0801T8, MMY-MAP0801T8, MMY-MAP0801T8, MMY-MAP0801T8, MMY-MAP1001T8, MMY-MAP1001T8, MMY-MAP1001T8, MMY-MAP1001T8, MMY-MAP1201T8, Front side Front side Front side Front side Front side Front side Front side Front side Front side Front side Front side Front side 10mm or more 20mm or more 20mm or more 20mm or more Front side (For work and service) 4040mm or more 184 HT7 HT7 HT7 HT7 HT7 HT7 HT7 HT7 HT7 500 or more Front side Front side Front side Front side Front side Front side Front side Front side HT8, HT8, HT8, HT8, HT8, HT8, HT8, HT8, HT8, HT8, HT8, HT8, HT8, HT8, HT8, HT8, HT8, HT8, HT7 HT7 HT7 HT7 HT7 HT7 HT7 HT7 HT7 10mm or more 1750mm or more ( HT7 HT7 HT7 HT7 HT7 HT7 HT7 HT7 HT7 800 or less (NOTES) 1. If there is an obstacle above the outdoor unit, ensure there is a minimum space of 2000mm or more above the unit. 2. Any obstacle around the perimeter of the outdoor unit must be kept 800mm or less. 3. Draw out the locally supplied piping at the front of the outdoor unit horizontally, keep a minimum of 500mm or more. between the outdoor unit and traversing pipe If the pipework is to be installed in this method. 4. Arrange each outdoor unit in order of its capacity. _ _ Follower 2 > Header > _ Follower 4 Follower 3 > HT8, HT8, HT8, HT8, HT8, HT8, HT8, HT8, HT8, 500mm or more HT7 HT7 HT7 HT7 HT7 HT7 HT7 HT7 HT7 Combination outdoor unit Follower Follower MMY-MAP0801T8, HT8, HT7 MMY-MAP0801T8, MMY-MAP0801T8, HT8, HT7 MMY-MAP0801T8, MMY-MAP1001T8, HT8, HT7 MMY-MAP0801T8, MMY-MAP1001T8, HT8, HT7 MMY-MAP1001T8, MMY-MAP1001T8, HT8, HT7 MMY-MAP1001T8, MMY-MAP1001T8, HT8, HT7 MMY-MAP1001T8, MMY-MAP1201T8, HT8, HT7 MMY-MAP1001T8, MMY-MAP1201T8, HT8, HT7 MMY-MAP1201T8, MMY-MAP1201T8, HT8, HT7 MMY-MAP1201T8, 800 or less HT8, HT8, HT8, HT8, HT8, HT8, HT8, HT8, HT8, (Note 3) (Note 4) (1000 or more) (Note 4) 500 or more 600 or more 500 or more MMY-AP3201T8, MMY-AP3401T8, MMY-AP3601T8, MMY-AP3801T8, MMY-AP4001T8, MMY-AP4201T8, MMY-AP4401T8, MMY-AP4601T8, MMY-AP4801T8, Header MMY-MAP0801T8, MMY-MAP1001T8, MMY-MAP1001T8, MMY-MAP1001T8, MMY-MAP1001T8, MMY-MAP1201T8, MMY-MAP1201T8, MMY-MAP1201T8, MMY-MAP1201T8, (Note 4) Combination unit Space required for service Branch header/Branch joint Branch header RBM-HY1043E, HY1083E, HY2043E, HY2083E Gas side A 80 x n 50 C B Insulator Liquid side A 80 x n B 61 B 74.5 Insulator Model RBM-HY1043E RBM-HY1083E RBM-HY2043E RBM-HY2083E Gas side A B 380 90 Liquid side 360 60 Gas side 700 90 Liquid side 680 60 Gas side 385.5 95.5 Liquid side 360 60 Gas side 705.5 95.5 Liquid side 680 60 C O /D O /E n , Accessory soket Q ty 83.6 _ 22.2 15.9 3 6 x 4, 9 x 4, 14 x 1, 18 x 1, 70 x 1 15.9 9.5 3 1 x 4, 6 x 1, 9 x 1 83.6 _ 22.2 15.9 7 6 x 8, 9 x 8, 14 x 1, 18 x 1, 70 x 1 15.9 9.5 7 1 x 8, 6 x 1, 9 x 1 89.3 _ 31.8 15.9 3 6 x 2, 9 x 2, 27 x 1, 59 x 1 15.9 9.5 3 1 x2 89.3 _ 31.8 15.9 7 6 x 7, 9 x 7, 27 x 1, 59 x 1 15.9 9.5 7 1 x7 T-shape branch joint RBM-BT13E Balance pipe Liquid side Gas side O / 38.1 O / 22.2 10 14 14 7 13 O / 9.5 O / 9.5 10 26 O / 22.2 O / 22.2 O / 38.1 O / 38.1 39 14 O / 9.5 7 10 7 32 52 78 15 , Accessory soket Q ty Gas side Liquid side 61 x 1, 62 x 1, 71 x 2, 73 x 2, 74 x 1, 14 x 2, 18 x 1, 85 x 2, 86 x 1 185 Y-shape branch joint RBM-BY53E, BY103E Liquid side O /D B O /B O /D O /C O /C O /D O /D Gas side Insulator Insulator A A RBM-BY203E, BY303E Liquid side O /D Insulator A 15 RBM-BY103E RBM-BY203E RBM-BY303E 186 A , Accessory soket Q ty Model RBM-BY53E Insulator 250 80 15.9 12.7 5 x 2, 54 x 2, 9 x 1, 51 x 1 Liquid side 200 70 12.7 1 x 2, 5 x 1 350 80 22.2 19.1 7 x 1, 10 x 1, 13 x 2, 18 x 1, 52 x 2, 70 x 1, 89 x 1 Liquid side 250 80 15.9 12.7 2 x 1, 5 x 2, 6 x 1, 9 x 1, 54 x 1 350 80 31.8 28.6 16 x 1, 20 x 1, 27 x 1, 43 x 2, 48 x 1, 49 x 1, 58 x 1, 59 x 1 Liquid side 250 80 15.9 15.9 3 x 1, 6 x 1, 9 x 2 Gas side Gas side Gas side Gas side 9.5 400 110 38.1 38.1 Liquid side 350 80 22.2 19.1 61 x 3, 62 x 2, 71 x 2, 73 x 1, 74 x 1, 75 x 1, 76 x 1, 77 x 1 4 x 1, 7 x 1, 10 x 1, 13 x 2, 14 x 1, 18 x 1, 52 x 1 B O /D O /C B O /C O /D O /D Gas side Accessory socket 1 2 O / 6.4 5 54 24 O /B A A O / 9.5 Outer dia O / 12.7 O /B 2 29 6.4 5 26 9.5 54 31 15.9 4 39 6.4 Outer dia 3 6 9 51 4 O /B O /B 7 39 9.5 36 12.7 32 9.5 13 33 15.9 9 28 12.7 52 43 22.2 51 38 19.1 89 53 28.6 6 O / 19.1 Outer dia 14 18 70 85 86 16 20 43 48 49 58 O /B A O /B O /B A O /B 14 40 15.9 16 50 15.9 18 40 19.1 20 52 19.1 70 54 28.6 43 50 22.2 85 41 12.7 48 54 9.5 86 44 9.5 49 52 12.7 58 62 34.9 A A A 10 35 6.4 A A O /B 3 Outer dia O / 22.2 10 13 52 89 O /B A O / 15.9 7 Outer dia O / 28.6 Outer dia 27 59 61 62 73 74 75 76 77 O /B A A O /B A O / 31.8 Outer dia O /B 27 49 28.6 59 59 34.9 O / 38.1 A O /B 61 55 34.9 62 66 41.3 71 66 28.6 73 66 22.2 74 66 19.1 75 64 15.9 76 62 12.7 77 62 9.5 15 Outer dia 187 188 16 Specifications 189 Foreword 190 16 Specifications Foreword TECHNICAL SPECIFICATIONS 50Hz Indoor unit (50Hz specification) 4-way Air Discharge Cassette Type MMU- AP0091H AP0121H AP0151H AP0181H AP0241H AP0271H AP0301H AP0361H AP0481H AP0561H Model name Cooling/Heating capacity (Note 1) (kW) 2.8/3.2 3.6/4.0 7.1/8.0 8.0/9.0 9.0/10.0 11.2/12.5 14.0/16.0 16.0/18.0 (A) 0.17 0.19 0.21 0.24 0.35 0.59 0.81 0.83 Power consumption (kW) 0.020 0.022 0.026 0.032 0.048 0.070 0.110 0.112 (A) 0.30 0.33 0.36 0.42 0.59 0.87 1.23 1.26 Running current Starting current Heat-insulating material attached Zinc hot dipping steel plate Main unit Appearance 5.6/6.3 1 phase 50Hz 230V (220 - 240V) (Separate power supply for indoor units is required.) Power supply Electrical characteristics 4.5/5.0 Ceiling Panel RBC-U21PG (W) -E Model Moon white (Munsell/2.5GY 9.0/0.5) Panel colour Height (mm) Main unit Width (mm) 840 Depth (mm) 840 Height (mm) 35 Width (mm) 950 Depth (mm) 950 Outer dimension Ceiling panel Main unit (kg) Ceiling panel (kg) 256 20 319 22 23 28 Total weight 4.5 Heat exchanger Finned tube Soundproof/Heat-insulating material Non-flammable insulation Turbo fan Fan Fan unit Standard air flow High (m3/h) (Mid./Low) Motor 800 (730/680) 930 (830/790) 1,050 (920/800) (W) 1,200 (920/820) 1,320 1,680 2,040 2,090 (1,110/850) (1,300/1,070) (1,430/1,130) (1,520/1,230) 60 90 Standard filter (Long life filter) Air filter Remote controller Controller Gas side Connecting Liquid side pipe (mm) O / 9.5 (mm) O / 12.7 O / 9.5 O / 6.4 Drain port (Nominal dia. mm) Sound pressure level(Note 2) (High/Mid./Low) (dB(A)) O / 15.9 25 (Polyvinyl chloride tube) 30/29/27 31/29/27 32/29/28 34/31/28 37/33/30 40/36/33 44/38/34 45/40/34 Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB O O O 16 O O O 191 50Hz 2-way Air Discharge Cassette Type MMU- AP0071WH AP0091WH AP0121WH AP0151WH AP0181WH AP0241WH AP0271WH AP0301WH Model name Cooling/Heating capacity (kW) 2.2/2.5 2.8/3.2 3.6/4.0 4.5/5.0 Running current 8.0/9.0 9.0/10.0 14.0/16.0 1 phase 50Hz 220V (A) 0.31 0.32 0.46 0.47 1.16 Electrical Power characteristics consumption (kW) 0.070 0.072 0.105 0.106 0.250 Power factor (%) 99 98 98 0.89 0.98 1.33 Starting current (A) 97 0.47 Main unit Appearance Ceiling panel 0.60 Heat-insulating material attached Model RBC-UW136PG Main unit Panel colour Outer dimension Width (mm) Depth (mm) Total weight Width (mm) Depth (mm) 398 1,350 1,650 550 620 8 1,520 1,000 1,898 680 650 (kg) 33 Ceiling panel (kg) 8 44 48 52 11 Heat exchanger 18 Finned tube Non-flammable insulation Soundproof/Heat-insulating material Centrifugal fan Fan Motor 406 830 Main unit Standard air flow Fan unit (High/Mid./Low) RBCUW466PG Light ivory (Munsell 10Y 9/0.5) Height (mm) Ceiling panel Zinc hot dipping steel plate RBC-UW266PG Height (mm) (m3/h) (W) 570/510/450 780/700/600 53 39 Air filter 1260/1140/960 1920/1500/1050 1140/960/720 53 92 Standard filter (Long life filter) Remote controller Controller Gas side Connecting Liquid side pipe (mm) O / 9.5 O / 12.7 Sound pressure level(Note 2) (High/Mid./Low) (dB(A)) O / 15.9 O / 9.5 O / 6.4 (mm) Drain port (Nominal dia. mm) 25 (Polyvinyl chloride tube) 34/32/30 35/33/30 38/35/33 40/37/34 45/42/39 Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB O O 192 7.1/8.0 1 phase 50Hz 230V (220 - 240V) (Separate power supply for indoor units is required.) Power supply 16 5.6/6.3 AP0481WH China only O O O O Foreword 50Hz 1-way Air Discharge Cassette Type Model name MMU- Cooling/Heating capacity (Note 1) (kW) Running current Power consumption Power factor Starting current Ceiling panel AP0121YH AP0151SH AP0181SH AP0241SH 2.2/2.5 2.8/3.2 3.6/4.0 4.5/5.0 5.6/6.3 7.1/8.0 (A) 0.24 0.48 0.55 (kW) 0.053 0.103 0.115 (%) 95 93 91 (A) 0.6 0.8 1.1 Heat-insulating material attached Main unit Appearance AP0091YH 1 phase 50Hz 230V (220 - 240V) (Separate power supply for indoor units is required.) Power supply Electrical characteristics (Note 2) AP0071YH Model Zinc hot dipping steel plate RBC-UY135PG RBC-US165PG RBC-US265PG W : Silky shade (1Y8.5/0.5) Panel colour Height (mm) 235 Width (mm) 850 Depth (mm) 400 655 Height (mm) 18 10 Width (mm) 1,050 Depth (mm) 470 Main unit (kg) 22 27 31 Ceiling panel (kg) 3.5 8 9 780/720/660 1,200/1,140/1,020 Main unit Outer dimension Ceiling panel 198 1,000 1,200 1,220 1,420 755 Total weight Heat exchanger Finned tube Soundproof/Heat-insulating material Non-flammable insulation Centrifugal fan Fan Fan unit Standard air flow (High/Mid./Low) Motor (m3h) (W) 540/480/420 34 22 Controller Remote controller Room thermostat Attached Air filter Connecting pipe Standard filter (Long life filter) Gas side (mm) Liquid side (mm) Drain port O / 9.5 O / 12.7 O / 9.5 O / 6.4 (Nominal dia. mm) Sound pressure level(Note 2)(High/Mid./Low) (dB(A)) O / 15.9 25 (Polyvinyl chloride tube) 42/39/34 42/39/35 43/41/37 Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB O O O 16 O O O 193 50Hz Concealed Duct Type MMD- AP0071BH AP0091BH AP0121BH AP0151BH AP0181BH AP0241BH AP0271BH AP0301BH AP0361BH AP0481BH AP0561BH Model name Cooling/Heating capacity (Note 1) (kW) 2.2/2.5 2.8/3.2 4.5/5.0 5.6/6.3 7.1/8.0 8.0/9.0 9.0/10.0 11.2/12.5 14.0/16.0 16.0/18.0 1 phase 50Hz 230V (220 - 240V) (Separate power supply for indoor units is required.) Power supply Electrical characteristics 3.6/4.0 (A) 0.29 0.34 0.43 0.52 0.61 0.83 0.98 Power consumption(kW) 0.033 0.039 0.050 0.060 0.071 0.107 0.128 0.5 0.59 0.75 0.90 1.05 1.44 1.70 Running current Starting current (A) Appearance Main unit Zinc hot dipping steel plate Height (mm) Main unit Width (mm) Depth (mm) 800 Height (mm) 9 Width (mm) Depth (mm) Outer dimension Suction ceiling panel 320 700 550 780 630 1,000 1,350 1,080 1,430 500 Main unit (kg) 28 32 43 55 Ceiling panel (kg) 3.5 4 6 7 Total weight Heat exchanger Finned tube Non-flammable insulation Soundproof/Heat-insulating material Centrifugal fan Fan Standard air flow High (Mid./Low) (m3/h) 480 (420/340) 570 650 780 (490/400) (540/480) (660/540) (W) 120 External static pressure (factory setting) (Pa) 50 (4 mmAq) External static pressure (Pa) 110 (10 mmAq) Fan unit Motor Air filter Connecting pipe 1,980 (1710/1490) Remote controller Gas side (mm) Liquid side (mm) O / 9.5 O / 12.7 Sound pressure level(Note 2) (High/Mid./Low) (dB(A)) O / 15.9 O / 6.4 O / 9.5 Drain port (Nominal dia. mm) 25 (Polyvinyl chloride tube) 30/28/26 31/29/27 32/30/28 33/31/29 34/32/29 36/34/32 36/34/32 Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB O O 194 1,260 1,620 (1080/870) (1410/1200) Standard filter (Long life filter) Controller 16 1,140 (990/870) O O O O 50Hz Concealed Duct High Static Pressure Type Model name MMD- Cooling/Heating capacity (Note 1) (kW) AP0181H AP0241H AP0271H AP0361H AP0481H AP0721H AP0961H 5.6/6.3 7.1/8.0 8.0/9.0 11.2/12.5 14.0/16.0 22.4/25.0 28.0/31.5 1 phase 50Hz 230V (220 - 240V) (Separate power supply for indoor units is required.) Power supply Running current Electrical Power consumption characteristics Power factor Starting current (A) 0.81 1.35 1.63 1.84 5.25 5.52 (kW) 0.184 0.299 0.368 0.414 1.200 1.260 (%) 99 96 98 98 99 99 (A) 1.3 3.5 4.1 4.8 13.6 14.8 Appearance Zinc hot dipping steel plate Outer Height x Width x Depth dimension (kg) Total weight 380 x 850 x 660 (mm) 50 52 470 x 1,380 x 1,250 67 150 56 Finned tube Heat exchanger Soundproof/Heat-insulating material Non-flammable insulation Centrifugal fan Fan (m3/h) Standard air flow Fan unit 380 x 1,200 x 660 900 1,320 1,600 2,100 260 160 Motor (W) External static pressure (Factory setting) (Pa) 137 External static pressure (Pa) 68.6-137-196 Air flow limit Lower limit/Upper limit (m3/h) 720/1,080 3,600 1,060/1,580 1,280/1,920 Air filter 4,200 370 x 3 1,680/2,520 2,880/4,320 3,360/5,040 Option or field supply Controller Remote controller Gas side Connecting Liquid side pipe Drain port (mm) O / 12.7 O / 15.9 O / 22.2 (mm) O / 6.4 O / 9.5 O / 12.7 (Nominal dia. mm) Sound pressure level(Note 2) (High/Mid./Low) (dB(A)) 25 (One side of male screw) 37 40 49 50 Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB O O O O O O 16 195 50Hz Under Ceiling Type Model name MMC- Cooling/Heating capacity (Note 1) (kW) AP0151H AP0181H AP0241H AP0271H AP0361H AP0481H 4.5/5.0 5.6/6.3 7.1/8.0 8.0/9.0 11.2/12.5 14.0/16.0 1 phase 50Hz 230V (220 - 240V) (Separate power supply for indoor units is required.) Power supply Electrical characteristics Running current (A) 0.29 0.32 0.42 0.78 0.84 Power consumption (kW) 0.033 0.038 0.050 0.091 0.110 Starting current 0.43 0.48 0.62 1.17 1.25 (A) Appearance White (Munsell 10Y 9.3/0.4) Outer dimension Height x Width x Depth (mm) 210 x 910 x 680 210 x 1,180 x 680 210 x 1,595 x 680 22 26 34 (kg) Total weight Finned tube Heat exchanger Non-flammable insulation Soundproof/Heat-insulating material Fan Fan unit Standard air flow (High/Mid./Low) Motor Centrifugal fan (m3/h) 720/600/540 (W) 780/660/540 30 Controller 1,110/900/840 1,650/1,380/1,2001,800/1,560/1,320 40 80 Remote controller Room thermostat Attached Air filter Standard filter (Long life filter) Gas side Connecting Liquid side pipe (mm) O / 12.7 O / 15.9 (mm) O / 6.4 O / 9.5 Drain port (Nominal dia. mm) Sound pressure level(Note 2) (High/Mid./Low) (dB(A)) 20 (Polyvinyl chloride tube) 35/32/30 36/33/30 38/36/33 41/38/35 43/40/37 Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB O O 16 196 O O O O 50Hz High Wall Type Model name MMK- Cooling/Heating capacity (Note 1) (kW) Running current Power consumption AP0091H AP0121H AP0151H AP0181H AP0241H 2.2/2.5 2.8/3.2 3.6/4.0 4.5/5.0 5.6/6.3 7.1/8.0 1 phase 50Hz 230V (220 - 240V) (Separate power supply for indoor units is required.) Power supply Electrical characteristics AP0071H (A) 0.30 0.32 0.35 (kW) 0.035 0.037 0.040 (A) 0.36 0.42 0.47 368 x 895 x 210 368 x 1,055 x 210 368 x 1,430 x 210 18 19 25 780/660/600 1,200/1,020/900 Starting current Suction grille and side panel Appearance Outer dimension Silky mist (Munsell 1Y 8.9/0.5) Discharge grille City gray (Munsell N6.5) Bottom surface Silky mist (Munsell 1Y 8.9/0.5) Height x Width x Depth Total weight (mm) (kg) Heat exchanger Finned tube Soundproof/Heat-insulating material Non-flammable insulation Fan Cross-flow fan Fan unit Standard air flow (High/Mid./Low) (m3/h) 600/540/480 (W) Motor outlet 30 Air filter Standard filter (Simple filter) Remote controller Controller Gas side (mm) Connecting Liquid side (mm) pipe Drain port (Nominal dia. mm) Sound pressure level(Note 2) (High/Mid./Low) (dB(A)) O / 12.7 O / 9.5 O / 15.9 O / 9.5 O / 6.4 20 (Polyvinyl chloride tube) 42/38/35 39/34/31 42/38/35 Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB O O O O O O 16 197 50Hz Floor Standing Cabinet Type Model name MML- Cooling/Heating capacity (Note 1) (kW) Electrical characteristics Power consumption Power factor Starting current AP0091H AP0121H AP0151H AP0181H AP0241H 2.2/2.5 2.8/3.2 3.6/4.0 4.5/5.0 5.6/6.3 7.1/8.0 1 phase 50Hz 230V (220 - 240V) (Separate power supply for indoor units is required.) Power supply Running current AP0071H (A) 0.26 0.43 0.47 (kW) 0.056 0.092 0.102 (%) 94 93 94 (A) 0.60 0.80 1.10 Appearance Outer dimension Silky shade (1Y8.5/0.5) Height x Width x Depth Total weight 630 x 950 x 230 (mm) 37 (kg) 40 Heat exchanger Finned tube Soundproof/Heat-insulating material Non-flammable insulation Fan Centrifugal fan Fan unit Standard air flow (High/Mid./Low) Motor outlet (m3/h) 900/780/650 480/420/360 (W) 1,080/930/780 70 45 Air filter Standard filter (Simple filter) Controller Connecting pipe 40 Remote controller Gas side (mm) Liquid side (mm) O / 9.5 O / 12.7 O / 6.4 (dB(A)) O / 9.5 20 (Polyvinyl chloride tube) Drain port (Nominal dia. mm) Sound pressure level(Note 2) (High/Mid./Low) O / 15.9 39/37/35 45/41/38 49/44/39 Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB O O 16 198 O O O O 50Hz Floor Standing Concealed Type Model name MML- Cooling/Heating capacity (Note 1) (kW) Electrical characteristics Power consumption Power factor Starting current AP0091BH AP0121BH AP0151BH AP0181BH AP0241BH 2.2/2.5 2.8/3.2 3.6/4.0 4.5/5.0 5.6/6.3 7.1/8.0 1 phase 50Hz 230V (220 - 240V) (Separate power supply for indoor units is required.) Power supply Running current AP0071BH (A) 0.25 0.45 0.46 (kW) 0.056 0.090 0.095 (%) 97 87 90 (A) 0.60 0.80 1.00 Appearance Zinc hot dipping steel plate Height x Width x Depth Outer dimension (mm) (kg) Total weight 600 x 745 x 220 600 x 1,045 x 220 21 29 Finned tube Heat exchanger Soundproof/Heat-insulating material Non-flammable insulation Centrifugal fan Fan Fan unit Standard air flow (High/Mid./Low) Motor Static pressure range (m3/h) (W) 460/400/300 740/600/490 19 70 (kPa) 0 Standard filter (Simple filter) Air filter Remote controller Controller Connecting pipe 950/790/640 Gas side (mm) Liquid side (mm) O / 9.5 O / 12.7 O / 15.9 O / 6.4 Drain port (Nominal dia. mm) O / 9.5 20 (One side of male screw) Sound pressure level(Note 2)(High/Mid./Low)(dB(A)) 36 (34/32) 42 (37/33) Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB O O O O O O 16 199 50Hz Floor Standing Type Model name MMF- Cooling/Heating capacity (Note 1) (kW) Electrical Power consumption characteristics Power factor Starting current AP0181H AP0241H AP0271H AP0361H AP0481H AP0561H 4.5/5.0 5.6/6.3 7.1/8.0 8.0/9.0 11.2/12.5 14.0/16.0 16.0/18.0 1 phase 50Hz 230V (220 - 240V) (Separate power supply for indoor units is required.) Power supply Running current AP0151H (A) 0.67 0.88 1.29 1.60 (kW) 0.150 0.190 0.280 0.350 (%) 97 (A) 0.90 94 1.10 Appearance Height x Width x Depth (mm) (kg) Total weight 1750 x 600 x 210 2.10 1750 x 600 x 390 49 48 Heat exchanger 65 Finned tube Soundproof/Heat-insulating material Non-flammable insulation Fan Standard air flow (High/Mid./Low) Motor Centrifugal fan (m3/h) (W) 900/780/660 1,200/1,020/840 1,920/1,680/1,380 2,160/1,860/1,560 37 63 11 16 Standard filter (Simple filter) Air filter Controller Connecting pipe 1.70 W : Silky shade (1Y 8.5/0.5) Outer dimension Fan unit 95 Remote controller Gas side (mm) O / 12.7 O / 15.9 Liquid side (mm) O / 6.4 O / 9.5 Drain port (Nominal dia. mm) Sound pressure level(Note 2)(High/Mid./Low) (dB(A)) 20 (One side of male screw) 46/43/38 49/45/40 51/48/44 54/50/46 Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB O O 16 200 O O O O 60Hz Indoor unit (60Hz specifications) 4-way Air Discharge Cassette Type Model name MMU- AP0091H AP0121H AP0151H AP0181H AP0241H AP0271H AP0301H AP0361H AP0481H AP0561H Cooling/Heating capacity (Note 1) (kW) 2.8/3.2 3.6/4.0 Power supply Starting current 7.1/8.0 8.0/9.0 (A) 0.22 0.26 0.37 0.61 0.85 0.87 0.020 0.022 0.026 0.032 0.048 0.070 0.110 0.112 0.30 0.33 0.36 0.42 0.59 0.87 1.23 1.26 Heat-insulating material attached Zinc hot dipping steel plate RBC-U21PG (W) -E Model Panel colour Moon white (Munsell/2.5GY 9.0/0.5) (mm) Main unit Width (mm) 840 Depth (mm) 840 Height (mm) 35 Width (mm) 950 Depth (mm) 950 Ceiling panel Main unit (kg) Ceiling panel (kg) Total weight 256 319 22 20 23 28 4.5 Heat exchanger Finned tube Soundproof/Heat-insulating material Non-flammable insulation Fan Turbo fan Fan unit Standard air flow High 3 (m /h) (Mid./Low) Motor 11.2/12.5 14.0/16.0 16.0/18.0 0.20 Height Outer dimension 9.0/10.0 0.18 Main unit Ceiling Panel 5.6/6.3 1 phase 60Hz 220V (Separate power supply for indoor units is required.) (A) Running current Electrical characteristics Power consumption (kW) Appearance 4.5/5.0 800 (730/680) 930 1,050 (830/790) (920/800) (W) 1,200 (920/820) 1,320 1,680 2,040 2,090 (1,110/850) (1,300/1,070) (1,430/1,130) (1,520/1,230) 60 Air filter 90 Standard filter (Long life filter) Controller Remote controller Gas side Connecting Liquid side pipe (mm) O / 9.5 (mm) O / 12.7 O / 6.4 O / 9.5 Drain port (Nominal dia. mm) Sound pressure level(Note 2) (High/Mid./Low) (dB(A)) O / 15.9 25 (Polyvinyl chloride tube) 30/29/27 31/29/27 32/29/28 34/31/28 37/33/30 40/36/33 44/38/34 45/40/34 Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB O O O 16 O O O 201 60Hz 2-way Air Discharge Cassette Type Model name MMU- Cooling/Heating capacity (kW) Electrical characteristics AP0091WH AP0121WH AP0151WH AP0181WH AP0241WH AP0271WH AP0301WH 2.2/2.5 2.8/3.2 3.6/4.0 4.5/5.0 5.6/6.3 7.1/8.0 8.0/9.0 9.0/10.0 1 phase 60Hz 220V (Separate power supply for indoor units is required.) Power supply Running current AP0071WH (A) 0.33 0.38 0.53 0.58 Power consumption (kW) 0.070 0.076 0.115 0.123 Power factor (%) 97 90 99 96 (A) 0.46 0.59 0.87 0.96 Heat-insulating material attached Zinc hot dipping steel plate Starting current Main unit Appearance Ceiling panel Main unit Outer dimension Model RBC-UW266PG RBC-UW136PG Panel colour Light ivory (Munsell 10Y 9/0.5) Height (mm) 398 Width (mm) Depth (mm) 1.350 830 550 Height (mm) Ceiling panel Width (mm) Depth (mm) 8 1,520 1,000 650 Main unit (kg) 33 Ceiling panel (kg) 8 44 48 Total weight 11 Heat exchanger Finned tube Soundproof/Heat-insulating material Non-flammable insulation Centrifugal fan Fan Fan unit Standard air flow (High/Mid./Low) Motor (m3/h) (W) 570/510/450 780/700/600 1,140/960/720 53 39 53 Air filter Standard filter (Long life filter) Controller Remote controller Gas side Connecting Liquid side pipe (mm) O / 12.7 O / 9.5 (mm) Sound pressure level(Note 2) (dB(A)) (High/Mid./Low) O / 9.5 25 (Polyvinyl chloride tube) 35/33/30 34/32/30 38/35/33 40/37/34 Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB O O 202 O / 15.9 O / 6.4 Drain port (Nominal dia.mm) 16 1,260/1,140/960 O O O O 60Hz 1-way Air Discharge Cassette Type Model name MMU- Cooling/Heating capacity (Note 1) (kW) Power supply Running current Electrical characteristics (Note 2) Power consumption Power factor Starting current Ceiling panel AP0091YH AP0121YH AP0151SH AP0181SH AP0241SH 2.2/2.5 2.8/3.2 3.6/4.0 4.5/5.0 5.6/6.3 7.1/8.0 1 phase 60Hz 220V (Separate power supply for indoor units is required.) (A) 0.26 0.54 0.61 (kW) 0.056 0.115 0.130 (%) 98 97 97 (A) 0.60 0.80 1.10 Main unit Appearance AP0071YH Heat-insulating material attached Model Zinc hot dipping steel plate RBC-US165PG RBC-UY135PG Panel colour RBC-US265PG W : Silky shade (1Y8.5/0.5) Height (mm) 235 Width (mm) 850 Depth (mm) 400 655 Height (mm) 18 10 Width (mm) 1,050 Depth (mm) 470 Main unit (kg) 22 27 31 Ceiling panel (kg) 3.5 8 9 780/720/660 1,200/1,140/1,020 Main unit Outer dimension Ceiling panel 198 1,000 1,200 1,220 1,420 755 Total weight Heat exchanger Finned tube Soundproof/Heat-insulating material Non-flammable insulation Centrifugal fan Fan Fan Standard air flow (High/Mid./Low) unit Motor (m3/h) (W) 540/480/420 34 22 Controller Remote controller Room thermostat Attached Air filter Connecting pipe Standard filter (Long life filter) Gas side (mm) Liquid side (mm) Drain port O / 12.7 O / 9.5 O / 9.5 O / 6.4 (Nominal dia. mm) Sound pressure level(Note 2)(High/Mid./Low) (dB(A)) O / 15.9 25 (Polyvinyl chloride tube) 42/39/35 42/39/34 43/41/37 Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB O O O 16 O O O 203 60Hz Concealed Duct Type Model name MMD- AP0071BH AP0091BH AP0121BH AP0151BH AP0181BH AP0241BH AP0271BH AP0301BH AP0361BH AP0481BH AP0561BH Cooling/Heating capacity (Note 1) (kW) 2.2/2.5 2.8/3.2 4.5/5.0 5.6/6.3 7.1/8.0 8.0/9.0 9.0/10.0 11.2/12.5 14.0/16.0 16.0/18.0 1 phase 60Hz 220V (Separate power supply for indoor units is required.) Power supply Electrical characteristics 3.6/4.0 (A) 0.30 0.35 0.45 0.55 0.64 0.87 1.03 Power consumption (kW) 0.033 0.039 0.050 0.060 0.071 0.107 0.128 0.5 0.59 0.75 0.90 1.05 1.44 1.70 Running current (A) Starting current Appearance Main unit Zinc hot dipping steel plate 320 Height (mm) Main unit Width (mm) Depth (mm) 800 Height (mm) 9 Width (mm) Depth (mm) Outer dimension Suction ceiling panel 550 700 630 780 1,000 1,350 1,080 1,430 500 Main unit (kg) 28 32 43 55 Ceiling panel (kg) 3.5 4 6 7 Total weight Heat exchanger Finned tube Non-flammable insulation Soundproof/Heat-insulating material Centrifugal fan Fan Standard air flow High (Mid./Low) (m3/h) 480 (420/340) 570 650 780 (490/400) (540/480) (660/540) (W) 120 External static pressure (factory setting) (Pa) 50 (4 mmAq) External static pressure (pa) 110 (10 mmAq) Fan unit Motor Air filter Connecting pipe 1,980 (1,710/1,490) Remote controller Gas side (mm) Liquid side (mm) O / 9.5 O / 12.7 Sound pressure level(Note 2) (High/Mid./Low) (dB(A)) O / 15.9 O / 6.4 O / 9.5 25 (Polyvinyl chloride tube) Drain port(Nominal dia. mm) 30/28/26 31/29/27 31/29/27 32/30/28 33/31/29 34/32/29 36/34/32 38/36/32 Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB O O 204 1,260 1,620 (1,080/870) (1,410/1,200) Standard filter (Long life filter) Controller 16 1,140 (990/870) O O O O 60Hz Concealed Duct High Static Pressure Type Model name MMD- Cooling/Heating capacity (Note 1) (kW) AP0181H AP0241H AP0271H AP0361H AP0481H AP0721H AP0961H 5.6/6.3 7.1/8.0 8.0/9.0 11.2/12.5 14.0/16.0 22.4/25.0 28.0/31.5 Power supply Running current Electrical characteristics Power consumption Power factor Starting current 1 phase 60Hz 220V (Separate power supply for indoor units is required.) (A) 0.92 1.80 2.07 2.26 7.10 7.42 (kW) 0.198 0.385 0.450 0.490 1.540 1.610 (%) 98 97 (A) 1.30 3.40 Appearance 99 3.90 4.35 13.00 13.60 Zinc hot dipping steel plate Outer Height x Width x Depth dimension (mm) (kg) Total weight 380 x 850 x 660 50 380 x 1,200 x 660 470 x 1,380 x 1,250 67 150 56 52 Heat exchanger Finned tube Soundproof/Heat-insulating material Non-flammable insulation Fan Centrifugal fan Standard air flow Fan unit 99 (m3/h) 900 1,600 1,320 2,100 Motor (W) External static pressure (Factory setting) (Pa) 137 External static pressure (Pa) 68.6-137-196 Air flow limit Lower limit/Upper limit (m3/h) 160 720/1,080 3,600 260 1,280/1,920 1,060/1,580 Air filter 4,200 370 x 3 1,680/2,520 2,880/4,320 3,360/5,040 Option or field supply Controller Remote controller Gas side Connecting Liquid side pipe (mm) O / 12.7 O / 15.9 O / 22.2 (mm) O / 6.4 O / 9.5 O / 12.7 Drain port (Nominal dia. mm) Sound pressure level(Note 2) (High/Mid./Low) (dB(A)) 25 (One side of male screw) 37 49 40 50 Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB O O O O O O 16 205 60Hz Under Ceiling Type Model name MMC- Cooling/Heating capacity (Note 1) (kW) AP0151H AP0181H AP0241H AP0271H AP0361H AP0481H 4.5/5.0 5.6/6.3 7.1/8.0 8.0/9.0 11.2/12.5 14.0/16.0 1 phase 60Hz 220V (Separate power supply for indoor units is required.) Power supply Electrical characteristics Running current (A) 0.30 0.34 0.44 0.82 0.87 Power consumption (kW) 0.033 0.038 0.050 0.091 0.110 (A) 0.43 0.48 0.62 1.17 1.25 Starting current White (Munsell 10Y 9.3/0.4) Appearance Outer Height x Width x Depth (mm) dimension 210 x 910 x 680 210 x 1,180 x 680 210 x 1,595 x 680 22 26 34 (kg) Total weight Heat exchanger Finned tube Soundproof/Heat-insulating material Non-flammable insulation Fan Centrifugal fan Fan unit Standard air flow (High/Mid./Low) Motor (m3/h) 780/660/540 720/600/540 30 (W) 1,110/900/840 1,650/1,380/1,2001,800/1,560/1,320 40 80 Remote controller Controller Attached Room thermostat Air filter Standard filter (Long life filter) Gas side Connecting Liquid side pipe (mm) O / 12.7 O / 15.9 (mm) O / 6.4 O / 9.5 Drain port(Nominal dia. mm) Sound pressure level(Note 2) (High/Mid./Low) (db(A)) 20 (Polyvinyl chloride tube) 35/32/30 36/33/30 38/36/33 41/38/35 43/40/37 Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB O O 16 206 O O O O 60Hz High Wall Type MMK- Model name Cooling/Heating capacity (Note 1) (kW) Power supply Electrical characteristics Running current Power consumption Starting current AP0071H AP0091H AP0121H AP0151H AP0181H AP0241H 2.2/2.5 2.8/3.2 3.6/4.0 4.5/5.0 5.6/6.3 7.1/8.0 1 phase 60Hz 220V (Separate power supply for indoor units is required.) (A) 0.32 0.34 0.35 (kW) 0.035 0.037 0.040 (A) 0.46 0.48 0.60 368 x 895 x 210 368 x 1,055 x 210 368 x 1,430 x 210 18 19 25 780/660/600 1,200/1,020/900 Silky mist (Munsell 1Y 8.9/0.5) Suction grille and side panel Appearance Outer dimension Discharge grille City gray (Munsell N6.5) Bottom surface Silky mist (Munsell 1Y 8.9/0.5) Height x Width x Depth (mm) (kg) Total weight Finned tube Heat exchanger Non-flammable insulation Soundproof/Heat-insulating material Cross-flow fan Fan Fan Standard air flow (High/Mid./Low) unit (m3/h) 600/540/480 (W) Motor outlet 30 Air filter Standard filter (Simple filter) Controller Remote controller Gas side (mm) Connecting Liquid side (mm) pipe Drain port (Nominal dia. mm) Sound pressure level(Note 2) (High/Mid./Low) (dB(A)) O / 9.5 O / 12.7 O / 15.9 O / 6.4 O / 9.5 20 (Polyvinyl chloride tube) 39/34/31 42/38/35 42/38/35 Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB O O O O O O 16 207 60Hz Floor Standing Cabinet Type Model name MML- Cooling/Heating capacity (Note 1) (kW) Power supply Running current Electrical characteristics Power consumption Power factor Starting current AP0071H AP0091H AP0121H AP0151H AP0181H AP0241H 2.2/2.5 2.8/3.2 3.6/4.0 4.5/5.0 5.6/6.3 7.1/8.0 1 phase 60Hz 220V (Separate power supply for indoor units is required.) (A) 0.25 0.44 0.53 (kW) 0.053 0.092 0.113 (%) 96 95 97 (A) 0.60 0.80 1.10 Silky shade (1Y8.5/0.5) Appearance Outer dimension Height x Width x Depth Total weight (mm) 630 x 950 x 230 37 (kg) 40 Heat exchanger Finned tube Soundproof/Heat-insulating material Non-flammable insulation Fan Centrifugal fan Fan unit Standard air flow (High/Mid./Low) Motor outlet (m3/h) 480/420/360 900/780/650 45 (W) 70 Air filter Standard filter (Simple filter) Controller Connecting pipe 1,080/930/780 Remote controller Gas side (mm) Liquid side (mm) O / 12.7 O / 9.5 O / 6.4 Drain port (Nominal dia. mm) Sound pressure level(Note 2) (High/Mid./Low) (dB(A)) O / 15.9 O / 9.5 20 (Polyvinyl chloride tube) 39/37/35 45/41/38 49/44/39 Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB O O 16 208 O O O O 60Hz Floor Standing Concealed Type Model name MML- Cooling/Heating capacity (Note 1) (kW) Power supply Running current Power consumption Electrical characteristics Power factor Starting current AP0071BH AP0091BH AP0121BH AP0151BH AP0181BH AP0241BH 2.2/2.5 2.8/3.2 3.6/4.0 4.5/5.0 5.6/6.3 7.1/8.0 1 phase 60Hz 220V (Separate power supply for indoor units is required.) (A) 0.27 0.46 0.51 (kW) 0.058 0.096 0.110 (%) 98 95 98 (A) 0.60 0.80 1.00 Appearance Zinc hot dipping steel plate Outer dimension Height x Width x Depth Total weight (mm) (kg) 600 x 745 x 220 600 x 1,045 x 220 21 29 Finned tube Heat exchanger Non-flammable insulation Soundproof/Heat-insulating material Fan Fan unit Standard air flow (High/Mid./Low) Motor Static pressure range Centrifugal fan (m3/h) (W) 460/400/300 740/600/490 19 70 (kPa) 0 Air filter Standard filter (Simple filter) Remote controller Controller Connecting pipe 950/790/640 Gas side (mm) Liquid side (mm) O / 9.5 O / 12.7 O / 15.9 O / 6.4 Drain port (Nominal dia. mm) O / 9.5 20 (One side of male screw) 36/34/32 Sound pressure level(Note 2)(High/Mid./Low) (dB(A)) 42/37/33 Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB O O O O O O 16 209 60Hz Floor Standing Type Model name MMF- Cooling/Heating capacity (Note 1) (kW) AP0151H AP0181H AP0241H AP0271H AP0361H AP0481H AP0561H 4.5/5.0 5.6/6.3 7.1/8.0 8.0/9.0 11.2/12.5 14.0/16.0 16.0/18.0 Power supply 1 phase 60Hz 220V (Separate power supply for indoor units is required.) Running current Electrical characteristics (A) 0.67 0.90 1.37 1.75 Power consumption (kW) 0.146 0.195 0.295 0.380 Power factor Starting current (%) 99 (A) 0.90 1.10 1.18 Height x Width x Depth (mm) (kg) Total weight 1,750 x 600 x 390 1,750 x 600 x 210 48 65 49 Heat exchanger Finned tube Soundproof/Heat-insulating material Non-flammable insulation Fan Centrifugal fan Fan unit Standard air flow (High/Mid./Low) Motor (m3/h) (W) 900/780/660 1,200/1,020/840 1,680/1,920/1,380 2,160/1,860/1,560 37 63 110 160 Air filter Standard filter (Simple filter) Controller Connecting pipe 2.30 W : Silky Shade (1Y 8.5/0.5) Appearance Outer dimension 99 98 Remote controller Gas side (mm) O / 12.7 O / 15.9 Liquid side (mm) O / 6.4 O / 9.5 20 (One side of male screw) Drain port (Nominal dia. mm) Sound pressure level(Note 2) (High/Mid./Low) (dB(A)) 46/43/38 49/45/40 51/48/44 54/50/46 Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. Note 2 : The sound levels are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB O O 16 210 O O O O 50Hz Outdoor unit (50Hz) Cooling Only Model name Heat Pump Outdoor unit type * Cooling capacity ( 1) * Standard heating capacity ( 1) * Power supply ( 2) Running current Power consumption Cooling Power factor Electrical characteristics ( 1) * Equivalent to 6HP Equivalent to 5HP Equivalent HP EER (Energy Efficiency Ratio) MMY- MAP0501T8 MAP0601T8 MAP0801T8 MAP1001T8 MAP1201T8 MMY- MAP0501HT8 MAP0601HT8 MAP1001HT8 MAP1201HT8 (kW) 14.0 16.0 MAP0801HT8 Inverter unit 22.4 28.0 33.5 (kW) 16.0 18.0 25.0 31.5 37.5 (A) 5.85 3 phase 50Hz 400V (380 - 415V) 11.55 8.62 7.28 18.30 (kW) 3.65 4.64 5.67 7.68 11.92 90 92 95 96 94 3.84 3.45 3.95 3.65 2.81 (%) (kW/kW) 1.0 1.0 1.0 1.0 1.0 Running current (A) 6.09 7.08 8.93 11.98 15.65 (kW) (%) 3.84 4.56 5.88 7.97 10.19 91 4.17 93 3.95 95 4.25 96 3.95 94 3.68 1.0 1.0 1.0 1.0 Height 1,800 x Width 990 x Depth 750 1.0 Power consumption Heating Power factor Starting current Total weight (kW/kW) (A) (mm) Cooling Only (kg) 227 Heat Pump (kg) 228 256 258 Colour Silky shade (Munsell 1Y8.5/0.5) Type (kW) Motor output 1.1 x 2 1.4 x 2 Fan 9,000 9,900 * Connecting method 4.2 x 2 10,500 Finned tube * (kg) 8.0 11 (kg) 8.5 12.5 (MPa) OFF : 2.90 Protective devices Connecting port dia 3.1 x 2 0.60 (m3/h) Cooling Only Refrigerant R410A (Charged refrigerant amount) ( 3) Heat Pump High-pressure switch Hermetic type 2.3 x 2 Propeller fan (kW) Motor output Air volume Heat exchanger Refrigerant piping specifications ( 4) Equivalent to 12HP (A) External dimension Fan unit Equivalent to 10HP Starting current EER (Energy Efficiency Ratio) Compressor Equivalent to 8HP ON : 3.73 * ( 5) Gas side (mm) Liquid side (mm) Balance pipe (mm) Gas side O / 15.9 O / 19.1 O / 9.5 Flare Brazing Flare Flare Balance pipe Max. equivalent length (m) Max. real length (m) Max. total pipe length (Real length) (m) Max. height difference (m) Control wiring 175 150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.) 300 Outdoor unit is higher than indoor unit : 50 * Outdoor unit is lower than indoor unit : 40 ( 6) Shield wire 1.25mm2 x 2 cores. up to 2000m When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m (Shield wire) 2.0mm2 x 2 cores. up to 2000m Central remote controller Max. No. of connected indoor units * 1 : Rated conditions O / 28.6 O / 12.7 Liquid side Sound pressure level O / 22.2 O / 9.5 (dB(A)) 8 10 13 16 20 55 56 57 58 59 Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height. + 10%. * 2 : The source voltage must not fluctuate more than 3 : The amount does not consider extra piping lengths. Refrigerant must be added on site in accordance with the actual piping length. * 4 : The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side. * O O O O O O System safety protection * 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor, High-pressure Sensor, Low pressure sensor, Over-current relay. 6 : * 30m when the height difference between indoor units exceeds 3m. 16 211 50Hz Outdoor unit (Combination) (50Hz) Equivalent HP Equivalent to 14HP AP1401T8 AP1401HT8 Equivalent to 16HP Equivalent to 18HP Equivalent to 20HP AP1601T8 AP1801T8 AP2001T8 Set Model name AP1601HT8 AP1801HT8 AP2001HT8 Outdoor unit type Inverter Cooling Only MMY- MAP0801T8 MAP0601T8 MAP0801T8 MAP0801T8 MAP1001T8 MAP0801T8 MAP1001T8 MAP1001T8 Outdoor unit model Heat Pump MMY- MAP0801HT8 MAP0601HT8 MAP0801HT8 MAP0801HT8 MAP1001HT8 MAP0801HT8 MAP1001HT8 MAP1001HT8 (kW) 38.4 45 50.4 56.0 Rated cooling capacity ( 1) 43.0 50.0 56.5 63.0 (kW) Standard heating capacity ( 1) Power supply ( 2) 3 phase 50Hz 400V (380 - 415V) (A) 21.29 24.31 17.08 18.54 Running current 14.16 16.17 11.12 12.20 Power consumption (kW) (%) 96 96 Power factor 94 95 Cooling (kW/kW) EER 3.56 3.46 3.45 3.69 (Energy Efficiency Ratio) Electrical 1.0 1.0 1.0 1.0 Starting current (A) characteristics 21.61 24.75 Running current 16.83 18.65 (A) ( 1) 14.37 16.46 10.96 12.28 Power consumption (kW) Power factor 96 96 94 95 (%) Heating EER (kW/kW) 3.93 3.83 3.92 4.07 (Energy Efficiency Ratio) Starting current 1.0 1.0 1.0 1.0 (A) (mm) External dimension Height 1,800 x Width 990 x Depth 750 (kg) Cooling Only 256 227 256 256 256 256 256 256 Total weight (kg) Heat Pump 258 228 258 258 258 258 258 258 Silky shade (Munsell 1Y8.5/0.5) Colour Hermetic type Type Compressor Motor output 3.1 x 2 2.3 x 2 2.3 x 2 1.4 x 2 2.3 x 2 3.1 x 2 (kW) Fan Propeller fan (kW) Motor output Fan unit 0.6 (m3/h) Air volume 10,500 9,900 9,900 9,000 9,900 10,500 Heat exchanger Finned tube (kg) Cooling Only Refrigerant R410A 11.0 8.0 11.0 11.0 11.0 11.0 11.0 11.0 Charged amount ( 3) (kg) Heat Pump 12.5 8.5 12.5 12.5 12.5 12.5 12.5 12.5 (MPa) High-pressure switch OFF : 2.90 ON : 3.73 Protective devices ( 5) O O O Gas side / 22.2 / 19.1 / 22.2 (m) Connecting O O O (m) Liquid side / 12.7 / 9.5 / 12.7 port dia. (m) Balance side O / 9.5 Brazing Gas side Connecting Flare Liquid side method Refrigerant Flare Balance side pipe spec. ( 4) 175 (m) Max. equivalent length Cooling Only Heat Pump * * MMYMMY- * * * * * Max. real length Max. total pipe length (Real length) Max. height difference (m) (m) Control wiring Central remote controller Max. No. of connected indoor units Sound pressure level * 1 : Rated conditions 150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.) (m) (dB(A)) 300 Outdoor unit is higher than indoor unit : 50 Outdoor unit is lower than indoor unit : 40 ( 6) Shield wire 1.25mm2 x 2 cores. up to 2000m When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and (Shield wire) 2.0mm2 x 2 cores. up to 2000m 27 30 33 23 60 60.5 61 59.5 * Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height. + 10%. * 2 : The source voltage must not fluctuate more than 3 : The amount does not consider extra piping lengths. Refrigerant must be added on site in accordance with the actual piping length. * 4 : The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side. * O O O System safety protection O O O * 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor, 16 212 High-pressure Sensor, Low pressure sensor, Over-current relay. 6 : * 30m when the height difference between indoor units exceeds 3m. 50Hz Equivalent HP Equivalent to 22HP Cooling Only Heat Pump Set Model name MMYMMY- AP2201T8 AP2201HT8 Outdoor unit type MMYCooling Only Outdoor unit model MMYHeat Pump (kW) Rated cooling capacity ( 1) (kW) Standard heating capacity ( 1) Power supply ( 2) (A) Running current Power consumption (kW) Power factor (%) Cooling (kW/kW) EER (Energy Efficiency Ratio) Electrical Starting current (A) characteristics Running current (A) ( 1) Power consumption (kW) (%) Power factor Heating (kW/kW) EER (Energy Efficiency Ratio) (A) Starting current (mm) External dimension (kg) Cooling Only Total weight Heat Pump (kg) Colour Type Compressor Motor output (kW) Fan (kW) Motor output Fan unit Air volume (m3/h) Heat exchanger (kg) Cooling Only Refrigerant R410A Charged amount ( 3) (kg) Heat Pump (MPa) High-pressure switch Protective devices (mm) Gas side Connecting (mm) Liquid side port dia. Balance side (mm) Gas side Connecting Liquid side method Refrigerant Balance side pipe spec. Max. equivalent length (m) ( 4) * * Inverter MAP0601T8 MAP1201T8 MAP0601HT8 MAP1201HT8 61.5 69.0 3 phase 50Hz 400V (380 - 415V) MAP0801T8 MAP0801HT8 MAP0801T8 MAP0801HT8 * * Max. real length Max. total pipe length (Real length) Max. height difference (m) 95 Control wiring Central remote controller Max. No. of connected indoor units Sound pressure level * 1 : Rated conditions 3.54 3.01 1.0 26.36 17.35 1.0 28.38 18.68 95 3.98 3.69 1.0 1.0 11.0 Height 1,800 x Width 990 x Depth 750 256 227 256 258 228 258 Silky shade (Munsell 1Y8.5/0.5) Hermetic type 1.4 x 2 4.2 x 2 Propeller fan 0.6 9,000 Finned tube 11.0 8.0 11.0 12.5 12.5 256 258 2.3 x 2 9,900 8.5 * O / 22.2 O / 12.7 (dB(A)) 256 258 3.1 x 2 10,500 11.0 12.5 OFF : 2.90 ON : 3.73 ( 5) O / 19.1 O / 9.5 O / 9.5 Brazing Flare Flare 175 12.5 O / 28.6 O / 22.2 O / 12.7 150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.) 300 (m) (m) MAP1001T8 MAP1001HT8 31.01 20.41 26.42 17.39 * * AP2211T8 AP2211HT8 Outdoor unit is higher than indoor unit : 50 Outdoor unit is lower than indoor unit : 40 ( 6) Shield wire 1.25mm2 x 2 cores. up to 2000m When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and (Shield wire) 2.0mm2 x 2 cores. up to 2000m 37 61.5 * Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height. + 10%. * 2 : The source voltage must not fluctuate more than 3 : The amount does not consider extra piping lengths. Refrigerant must be added on site in accordance with the actual piping length. * * 4 : The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side. O O O O O O System safety protection * 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor, High-pressure Sensor, Low pressure sensor, Over-current relay. * 6 : 30m when the height difference between indoor units exceeds 3m. 16 213 50Hz Equivalent HP Equivalent to 24HP Cooling Only Heat Pump Set Model name MMYMMY- Outdoor unit type Cooling Only MMYOutdoor unit model Heat Pump MMYRated cooling capacity ( 1) (kW) Standard heating capacity ( 1) (kW) Power supply ( 2) (A) Running current Power consumption (kW) Cooling Power factor (%) (kW/kW) EER (Energy Efficiency Ratio) Electrical Starting current (A) characteristics Running current (A) ( 1) Power consumption (kW) Heating Power factor (%) (kW/kW) EER (Energy Efficiency Ratio) (A) Starting current (mm) External dimension (kg) Cooling Only Total weight (kg) Heat Pump Colour Type Compressor (kW) Motor output Fan (kW) Motor output Fan unit Air volume (m3/h) Heat exchanger (kg) Cooling Only Refrigerant R410A Charged amount ( 3) Heat Pump (kg) High-pressure switch (MPa) Protective devices Gas side (mm) Connecting Liquid side (mm) port dia. Balance side (mm) Gas side Connecting Liquid side method Refrigerant Balance side pipe spec. Max. equivalent length (m) ( 4) Max. real length (m) Max. total pipe length (m) (Real length) * * Inverter MAP0801T8 MAP1201T8 MAP0801HT8 MAP1201HT8 68.0 76.5 3 phase 50Hz 400V (380 - 415V) MAP0801T8 MAP0801HT8 MAP0801T8 MAP0801HT8 * * * * Max. height difference (m) Control wiring Central remote controller Max. No. of connected indoor units Sound pressure level * 1 : Rated conditions AP2411T8 AP2411HT8 AP2401T8 AP2401HT8 27.73 18.44 96 38.02 25.02 95 3.69 2.72 1.0 27.96 18.79 97 1.0 32.06 21.32 96 4.07 3.59 1.0 1.0 Height 1,800 x Width 990 x Depth 750 256 256 256 258 258 258 Silky shade (Munsell 1Y8.5/0.5) Hermetic type 2.3 x 2 Propeller fan 0.6 9,900 Finned tube 11.0 11.0 11.0 12.5 12.5 12.5 OFF : 2.90 ON : 3.73 ( 5) O / 22.2 O / 12.7 O / 9.5 Brazing Flare Flare 175 256 258 11.0 12.5 MAP1201T8 MAP1201HT8 * 256 258 4.2 x 2 10,500 11.0 12.5 O / 28.6 150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.) 300 Outdoor unit is higher than indoor unit : 50 Outdoor unit is lower than indoor unit : 40 ( 6) Shield wire 1.25mm2 x 2 cores. up to 2000m When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and (Shield wire) 2.0mm2 x 2 cores. up to 2000m * 40 62 (dB(A)) Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height. + 10%. * 2 : The source voltage must not fluctuate more than 3 : The amount does not consider extra piping lengths. Refrigerant must be added on site in accordance with the actual piping length. * * 4 : The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side. O O O System safety protection O O O * 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor, 16 214 High-pressure Sensor, Low pressure sensor, Over-current relay. * 6 : 30m when the height difference between indoor units exceeds 3m. 50Hz Equivalent to 26HP Equivalent HP Cooling Only Heat Pump MMYMMY- AP2601T8 AP2601HT8 (A) (mm) (kg) (kg) 1.0 Equivalent to 28HP Equivalent to 30HP AP2801T8 AP3001T8 Set Model name AP2801HT8 AP3001HT8 Outdoor unit type Inverter Cooling Only MMY- MAP1001T8 MAP0801T8 MAP0801T8 MAP1001T8 MAP1001T8 MAP0801T8 MAP1001T8 MAP1001T8 MAP1001T8 Outdoor unit model Heat Pump MMY- MAP1001HT8 MAP0801HT8 MAP0801HT8 MAP1001HT8 MAP1001HT8 MAP0801HT8 MAP1001HT8 MAP1001HT8 MAP1001HT8 (kW) 78.5 84.0 73 Rated cooling capacity ( 1) (kW) Standard heating capacity ( 1) 88.0 95.0 81.5 3 phase 50Hz 400V (380 - 415V) Power supply ( 2) (A) 33.48 36.48 30.51 Running current 22.27 24.26 Power consumption (kW) 20.29 (%) Power factor 96 Cooling (kW/kW) EER 3.52 3.46 3.60 (Energy Efficiency Ratio) Electrical (A) 1.0 1.0 1.0 Starting current characteristics (A) Running current 33.98 36.93 31.16 ( 1) Power consumption (kW) 22.60 24.82 20.51 (%) 96 97 95 Heating Power factor (kW/kW) EER 3.89 3.83 3.97 (Energy Efficiency Ratio) * * * * Starting current External dimension Cooling Only Heat Pump Total weight 256 258 256 258 256 258 Colour Type Motor output Fan Motor output Fan unit Air volume Heat exchanger Cooling Only Refrigerant R410A Charged amount ( 3) Heat Pump High-pressure switch Protective devices Gas side Connecting Liquid side port dia. Balance side Gas side Connecting Liquid side method Refrigerant Balance side pipe spec. ( 4) Max. equivalent length Compressor * * Max. real length Max. total pipe length (Real length) Max. height difference (kW) (kW) (m3/h) (kg) (kg) (MPa) 11.0 12.5 9,900 11.0 12.5 11.0 12.5 1.0 256 258 256 258 256 258 3.1 x 2 10,500 11.0 12.5 11.0 12.5 11.0 12.5 * (m) 175 (m) 150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.) (m) 300 (m) Outdoor unit is higher than indoor unit : 50 Outdoor unit is lower than indoor unit : 40 ( 6) Shield wire 1.25mm2 x 2 cores. up to 2000m When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and (Shield wire) 2.0mm2 x 2 cores. up to 2000m 47 48 43 62.5 63 62 Central remote controller * 1 : Rated conditions 10,500 (mm) (mm) (mm) Control wiring Max. No. of connected indoor units Sound pressure level 2.3 x 2 1.0 Height 1,800 x Width 990 x Depth 750 256 256 256 258 258 258 Silky shade (Munsell 1Y8.5/0.5) Hermetic type 3.1 x 2 2.3 x 2 Propeller fan 0.6 9,900 10,500 Finned tube 11.0 11.0 11.0 12.5 12.5 12.5 OFF : 2.90 ON : 3.73 ( 5) O / 22.2 O / 12.7 O / 9.5 Brazing Flare Flare (dB(A)) * Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height. + 10%. * 2 : The source voltage must not fluctuate more than 3 : The amount does not consider extra piping lengths. Refrigerant must be added on site in accordance with the actual piping length. * * 4 : The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side. O O O O O O System safety protection * 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor, High-pressure Sensor, Low pressure sensor, Over-current relay. * 6 : 30m when the height difference between indoor units exceeds 3m. 16 215 50Hz Equivalent to 32HP Equivalent HP Cooling Only Heat Pump Set Model name MMYMMY- AP3201T8 AP3201HT8 Outdoor unit type Cooling Only MMYOutdoor unit model Heat Pump MMYRated cooling capacity ( 1) (kW) Standard heating capacity ( 1) (kW) Power supply ( 2) Running current (A) Power consumption (kW) Power factor (%) Cooling EER (kW/kW) (Energy Efficiency Ratio) Electrical Starting current (A) characteristics Running current (A) ( 1) Power consumption (kW) (%) Power factor Heating EER (kW/kW) (Energy Efficiency Ratio) Starting current (A) (mm) External dimension Cooling Only (kg) Total weight (kg) Heat Pump Colour Type Compressor (kW) Motor output * * MAP0801T8 MAP0801T8 MAP0801HT8 MAP0801HT8 Fan Fan unit Motor output Air volume Heat exchanger Cooling Only Refrigerant R410A Charged amount ( 3) Heat Pump High-pressure switch Protective devices Gas side Connecting Liquid side port dia. Balance side Gas side Connecting Liquid side method Refrigerant Balance side pipe spec. ( 4) Max. equivalent length * * Inverter MAP0801T8 MAP1201T8 MAP0801HT8 MAP1201HT8 90.0 100.0 3 phase 50Hz 400V (380 - 415V) MAP0801T8 MAP0801HT8 * * Max. real length Max. total pipe length (Real length) Max. height difference (kg) (kg) (MPa) 11.0 12.5 MAP1001T8 MAP1001T8 MAP1001HT8 MAP1001HT8 37.09 24.41 95 43.08 28.65 96 3.69 3.14 1.0 37.32 24.56 95 1.0 40.69 26.78 95 4.07 3.73 1.0 1.0 Height 1,800 x Width 990 x Depth 750 256 256 256 258 258 258 Silky shade (Munsell 1Y8.5/0.5) Hermetic type 2.3 x 2 4.2 x 2 Propeller fan 0.6 9,900 Finned tube 11.0 12.5 11.0 12.5 O / 22.2 (mm) (mm) (mm) 256 258 256 258 3.1 x 2 10,500 11.0 11.0 12.5 12.5 OFF : 2.90 ON : 3.73 ( 5) O / 28.6 O / 12.7 O / 9.5 Brazing Flare Flare 11.0 12.5 * 11.0 12.5 O / 22.2 (m) 175 (m) 150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.) (m) (m) Central remote controller * 1 : Rated conditions 256 258 (kW) (m3/h) Control wiring Max. No. of connected indoor units Sound pressure level 256 258 AP3211T8 AP3211HT8 (dB(A)) 300 Outdoor unit is higher than indoor unit : 50 Outdoor unit is lower than indoor unit : 40 ( 6) Shield wire 1.25mm2 x 2 cores. up to 2000m When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and (Shield wire) 2.0mm2 x 2 cores. up to 2000m 48 63 * Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height. + 10%. * 2 : The source voltage must not fluctuate more than 3 : The amount does not consider extra piping lengths. Refrigerant must be added on site in accordance with the actual piping length. * 4 : The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side. * O O O System safety protection O O O * 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor, 16 216 High-pressure Sensor, Low pressure sensor, Over-current relay. 6 : * 30m when the height difference between indoor units exceeds 3m. 50Hz Equivalent to 34HP Equivalent HP Cooling Only Heat Pump Set Model name MMYMMY- AP3411T8 AP3411HT8 AP3401T8 AP3401HT8 Inverter Outdoor unit type Cooling Only MMY- MAP1001T8 Outdoor unit model Heat Pump MMY- MAP1001HT8 (kW) Rated cooling capacity ( 1) Standard heating capacity ( 1) (kW) Power supply ( 2) (A) Running current Power consumption (kW) (%) Power factor Cooling (kW/kW) EER (Energy Efficiency Ratio) Electrical (A) Starting current characteristics (A) Running current ( 1) Power consumption (kW) (%) Power factor Heating (kW/kW) EER (Energy Efficiency Ratio) Starting current (A) (mm) External dimension (kg) 256 Cooling Only Total weight (kg) Heat Pump 258 Colour Type Compressor (kW) 3.1 x 2 Motor output Fan (kW) Motor output Fan unit Air volume (m3/h) 10,500 Heat exchanger 11.0 Refrigerant R410A (kg) Cooling Only Charged amount ( 3) Heat Pump 12.5 (kg) (MPa) High-pressure switch Protective devices Gas side (mm) Connecting Liquid side (mm) port dia. Balance side (mm) Gas side Connecting Liquid side Refrigerant method Balance side pipe spec. ( 4) (m) Max. equivalent length * * MAP0801T8 MAP0801HT8 MAP0801T8 MAP0801HT8 MAP0801T8 MAP1201T8 MAP0801HT8 MAP1201HT8 96.0 108.0 3 phase 50Hz 400V (380 - 415V) * * * * Max. real length Max. total pipe length (Real length) Max. height difference (m) Control wiring Central remote controller Max. No. of connected indoor units Sound pressure level * 1 : Rated conditions 39.89 26.53 96 50.26 33.08 95 3.62 2.90 1.0 40.22 27.03 97 1.0 44.42 29.54 96 4.00 3.66 1.0 Height 1,800 x Width 990 x Depth 750 256 256 256 256 256 258 258 258 258 258 Silky shade (Munsell 1Y8.5/0.5) Hermetic type 2.3 x 2 4.2 x 2 Propeller fan 0.6 9,900 10,500 Finned tube 11.0 11.0 11.0 11.0 11.0 12.5 12.5 12.5 12.5 12.5 OFF : 2.90 ON : 3.73 ( 5) O O / 22.2 / 28.6 O / 12.7 O / 9.5 Brazing Flare Flare 175 1.0 * (dB(A)) 256 258 3.1 x 2 11.0 12.5 O / 22.2 150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.) (m) (m) MAP1201T8 MAP1001T8 MAP1201HT8 MAP1001HT8 300 Outdoor unit is higher than indoor unit : 50 Outdoor unit is lower than indoor unit : 40 ( 6) Shield wire 1.25mm2 x 2 cores. up to 2000m When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and (Shield wire) 2.0mm2 x 2 cores. up to 2000m 48 63.5 63.5 * Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height. + 10%. * 2 : The source voltage must not fluctuate more than 3 : The amount does not consider extra piping lengths. Refrigerant must be added on site in accordance with the actual piping length. * * 4 : The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side. O O O O O O System safety protection * 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor, High-pressure Sensor, Low pressure sensor, Over-current relay. * 6 : 30m when the height difference between indoor units exceeds 3m. 16 217 50Hz Equivalent HP Equivalent to 36HP Cooling Only Heat Pump Set Model name AP3601T8 AP3601HT8 MMYMMY- AP3611T8 AP3611HT8 Inverter Cooling Only MMY- MAP1001T8 MAP1001T8 MAP0801T8 MAP0801T8 MAP1201T8 Outdoor unit model Heat Pump MMY- MAP1001HT8 MAP1001HT8 MAP0801HT8 MAP0801HT8 MAP1201HT8 (kW) 101.0 Rated cooling capacity ( 1) (kW) Standard heating capacity ( 1) 113.0 3 phase 50Hz 400V (380 - 415V) Power supply ( 2) 42.67 (A) Running current Power consumption (kW) 28.38 (%) Power factor 96 Cooling EER (kW/kW) 3.56 (Energy Efficiency Ratio) Electrical (A) Starting current 1.0 characteristics ( 1) (A) Running current 43.21 Power consumption (kW) 28.74 (%) 96 Heating Power factor EER (kW/kW) 3.93 (Energy Efficiency Ratio) (A) Starting current 1.0 (mm) External dimension Height 1,800 x Width 990 x Depth 750 Cooling Only (kg) 256 256 256 256 256 Total weight Heat Pump (kg) 258 258 258 258 258 Colour Silky shade (Munsell 1Y8.5/0.5) Type Hermetic type Compressor (kW) 2.3 x 2 Motor output 3.1 x 2 Propeller fan Fan Motor output 0.6 (kW) Fan unit (m3/h) 9,900 Air volume 10,500 Finned tube Heat exchanger Outdoor unit type * * MAP1201T8 MAP1201T8 MAP1201HT8 MAP1201HT8 * 57.06 37.16 94 2.72 1.0 48.36 31.49 94 * Cooling Only Heat Pump (kg) (kg) (MPa) Gas side Connecting Liquid side port dia. Balance side Gas side Connecting Liquid side method Balance side (mm) (mm) (mm) Refrigerant R410A Charged amount ( 3) High-pressure switch Protective devices * Refrigerant pipe spec. ( 4) * 11.0 12.5 11.0 12.5 11.0 12.5 O / 22.2 3.59 1.0 256 258 256 258 4.2 x 2 10,500 11.0 11.0 12.5 12.5 OFF : 2.90 ON : 3.73 ( 5) 11.0 12.5 * 11.0 12.5 O / 28.6 O / 12.7 Max. equivalent length (m) O / 9.5 Brazing Flare Flare 175 Max. real length Max. total pipe length (Real length) (m) 150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.) Max. height difference (m) (m) Control wiring Central remote controller Max. No. of connected indoor units Sound pressure level * 1 : Rated conditions (dB(A)) 300 Outdoor unit is higher than indoor unit : 50 Outdoor unit is lower than indoor unit : 40 ( 6) Shield wire 1.25mm2 x 2 cores. up to 2000m When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and (Shield wire) 2.0mm2 x 2 cores. up to 2000m 48 63.5 64 * Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height. + 10%. * 2 : The source voltage must not fluctuate more than 3 : The amount does not consider extra piping lengths. Refrigerant must be added on site in accordance with the actual piping length. * * 4 : The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side. O O O System safety protection O O O * 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor, 16 218 High-pressure Sensor, Low pressure sensor, Over-current relay. * 6 : 30m when the height difference between indoor units exceeds 3m. 50Hz Equivalent HP Cooling Only Heat Pump Set Model name MMYMMY- Equivalent to 38HP Equivalent to 40HP AP3801T8 AP3801HT8 AP4001T8 AP4001HT8 Outdoor unit type Inverter Cooling Only MMY- MAP1001T8 MAP1001T8 MAP1001T8 MAP0801T8 MAP1001T8 MAP1001T8 MAP1001T8 MAP1001T8 Outdoor unit model Heat Pump MMY- MAP1001HT8 MAP1001HT8 MAP1001HT8 MAP0801HT8 MAP1001HT8 MAP1001HT8 MAP1001HT8 MAP1001HT8 (kW) Rated cooling capacity ( 1) 112.0 106.5 Standard heating capacity ( 1) (kW) 126.5 119.5 Power supply ( 2) 3 phase 50Hz 400V (380 - 415V) (A) Running current 48.63 45.65 32.34 Power consumption (kW) 30.36 Power factor 96 (%) Cooling EER (kW/kW) 3.46 3.51 (Energy Efficiency Ratio) Electrical Starting current (A) 1.0 1.0 characteristics (A) Running current 49.69 46.36 ( 1) Power consumption (kW) 33.05 30.83 (%) 96 Heating Power factor (kW/kW) EER 3.83 3.88 (Energy Efficiency Ratio) (A) 1.0 Starting current 1.0 (mm) External dimension Height 1,800 x Width 990 x Depth 750 (kg) Cooling Only 256 256 256 256 256 256 256 256 Total weight (kg) Heat Pump 258 258 258 258 258 258 258 258 Colour Silky shade (Munsell 1Y8.5/0.5) Type Hermetic type Compressor (kW) Motor output 3.1 x 2 2.3 x 2 3.1 x 2 Fan Propeller fan Fan unit Motor output (kW) 0.6 10,500 9,900 10,500 (m3/h) Air volume Finned tube Heat exchanger (kg) Cooling Only 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 Refrigerant R410A (kg) Charged amount ( 3) Heat Pump 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 High-pressure switch (MPa) OFF : 2.90 ON : 3.73 ( 5) Protective devices Gas side (mm) O / 22.2 Connecting Liquid side O / 12.7 (mm) port dia. Balance side (mm) O / 9.5 Gas side Brazing Connecting Liquid side Flare method Flare Balance side Refrigerant pipe spec. (m) 175 Max. equivalent length ( 4) 150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.) (m) Max. real length Max. total pipe length (m) 300 (Real length) Outdoor unit is higher than indoor unit : 50 (m) Max. height difference Outdoor unit is lower than indoor unit : 40 ( 6) Control wiring Shield wire 1.25mm2 x 2 cores. up to 2000m When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and Central remote controller (Shield wire) 2.0mm2 x 2 cores. up to 2000m Max. No. of connected indoor units 48 (dB(A)) 64 Sound pressure level * * * * * * * * * 1 : Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height. + 10%. * 2 : The source voltage must not fluctuate more than 3 : The amount does not consider extra piping lengths. Refrigerant must be added on site in accordance with the actual piping length. * * 4 : The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side. O O O O O O System safety protection * 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor, High-pressure Sensor, Low pressure sensor, Over-current relay. * 6 : 30m when the height difference between indoor units exceeds 3m. 16 219 50Hz Equivalent to 42HP AP4201T8 AP4201HT8 Equivalent HP Cooling Only Heat Pump Set Model name MMYMMY- Outdoor unit type Cooling Only MMYOutdoor unit model Heat Pump MMY(kW) Rated cooling capacity ( 1) (kW) Standard heating capacity ( 1) Power supply ( 2) (A) Running current Power consumption (kW) (%) Power factor Cooling EER (kW/kW) (Energy Efficiency Ratio) Electrical Starting current (A) characteristics ( 1) Running current (A) Power consumption (kW) (%) Heating Power factor EER (kW/kW) (Energy Efficiency Ratio) (A) Starting current (mm) External dimension (kg) Cooling Only Total weight (kg) Heat Pump Colour Type Compressor (kW) Motor output Fan Fan unit (kW) Motor output (m3/h) Air volume Heat exchanger (kg) Cooling Only Refrigerant R410A Charged amount ( 3) (kg) Heat Pump (MPa) High-pressure switch Protective devices Gas side (mm) Connecting Liquid side (mm) port dia. Balance side (mm) Gas side Connecting Liquid side method Balance side Refrigerant pipe spec. Max. equivalent length (m) ( 4) Max. real length (m) Max. total pipe length (m) (Real length) * * * Inverter MAP1201T8 MAP1001T8 MAP1001T8 MAP1001T8 MAP1201T8 MAP1201T8 MAP1001T8 MAP1001T8 MAP1201HT8 MAP1001HT8 MAP1001HT8 MAP1001HT8 MAP1201HT8 MAP1201HT8 MAP1001HT8 MAP1001HT8 123.5 118.0 138.5 132.0 3 phase 50Hz 400V (380 - 415V) 55.24 62.28 36.74 40.99 96 95 * * * Max. height difference (m) Control wiring Central remote controller Max. No. of connected indoor units Sound pressure level * 1 : Rated conditions (dB(A)) Equivalent to 44HP AP4401T8 AP4401HT8 3.21 3.01 1.0 5.39 35.14 1.0 56.76 37.36 95 3.76 3.69 1.0 256 258 256 258 4.2 x 2 11.0 12.5 11.0 12.5 1.0 Height 1,800 x Width 990 x Depth 750 256 256 256 256 258 258 258 258 Silky shade (Munsell 1Y8.5/0.5) Hermetic type 3.1 x 2 4.2 x 2 11.0 12.5 O / 22.2 O / 28.6 256 258 256 258 3.1 x 2 Propeller fan 0.6 10,500 Finned tube 11.0 11.0 11.0 12.5 12.5 12.5 OFF : 2.90 ON : 3.73 ( 5) O / 28.6 O / 12.7 O / 9.5 Brazing Flare Flare 175 11.0 12.5 * 11.0 12.5 O / 22.2 150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.) 300 Outdoor unit is higher than indoor unit : 50 Outdoor unit is lower than indoor unit : 40 ( 6) Shield wire 1.25mm2 x 2 cores. up to 2000m When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and (Shield wire) 2.0mm2 x 2 cores. up to 2000m 48 64.5 * Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height. + 10%. * 2 : The source voltage must not fluctuate more than 3 : The amount does not consider extra piping lengths. Refrigerant must be added on site in accordance with the actual piping length. * * 4 : The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side. O O O System safety protection O O O * 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor, 16 220 High-pressure Sensor, Low pressure sensor, Over-current relay. * 6 : 30m when the height difference between indoor units exceeds 3m. 50Hz Equivalent HP Cooling Only Heat Pump Set Model name MMYMMY- Equivalent to 46HP AP4601T8 AP4601HT8 Equivalent to 48HP AP4801T8 AP4801HT8 Outdoor unit type Inverter Cooling Only MMY- MAP1201T8 MAP1201T8 MAP1201T8 MAP1001T8 MAP1201T8 MAP1201T8 MAP1201T8 MAP1201T8 Heat Pump MMY- MAP1201HT8 MAP1201HT8 MAP1201HT8 MAP1001HT8 MAP1201HT8 MAP1201HT8 MAP1201HT8 MAP1201HT8 (kW) Rated cooling capacity ( 1) 135.0 130.0 Standard heating capacity ( 1) (kW) 150.0 145.0 3 phase 50Hz 400V (380 - 415V) Power supply ( 2) 75.47 Running current (A) 69.27 49.67 45.59 Power consumption (kW) Power factor 95 (%) Cooling EER (kW/kW) 2.72 2.85 (Energy Efficiency Ratio) Electrical Starting current (A) 1.0 1.0 characteristics (A) 64.19 Running current 60.55 ( 1) Power consumption (kW) 41.80 39.85 (%) 94 95 Heating Power factor (kW/kW) EER 3.59 3.64 (Energy Efficiency Ratio) (A) Starting current 1.0 1.0 (mm) Height 1,800 x Width 990 x Depth 750 External dimension (kg) 256 256 256 256 256 256 256 256 Cooling Only Total weight Heat Pump (kg) 258 258 258 258 258 258 258 258 Silky shade (Munsell 1Y8.5/0.5) Colour Type Hermetic type Compressor (kW) 3.1 x 2 4.2 x 2 4.2 x 2 Motor output Fan Propeller fan Fan unit Motor output 0.6 (kW) 10,500 (m3/h) Air volume Finned tube Heat exchanger (kg) Cooling Only 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 Refrigerant R410A (kg) Charged amount ( 3) Heat Pump 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 (MPa) High-pressure switch OFF : 2.90 ON : 3.73 ( 5) Protective devices Gas side (mm) O O O / 28.6 / 22.2 / 28.6 Connecting Liquid side O / 12.7 (mm) port dia. Balance side (mm) O / 9.5 Brazing Gas side Connecting Liquid side Flare method Balance side Flare Refrigerant pipe spec. (m) 160 Max. equivalent length ( 4) 135 (If the total bend length exceeds 135m, use the max equivalent length as the standard.) Max. real length (m) Outdoor unit model * * * * * * * Max. total pipe length (Real length) Max. height difference (m) Control wiring Central remote controller Max. No. of connected indoor units Sound pressure level * 1 : Rated conditions 300 (m) (dB(A)) Outdoor unit is higher than indoor unit : 50 Outdoor unit is lower than indoor unit : 40 ( 6) Shield wire 1.25mm2 x 2 cores. up to 2000m When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and (Shield wire) 2.0mm2 x 2 cores. up to 2000m 48 65 * Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height. + 10%. * 2 : The source voltage must not fluctuate more than 3 : The amount does not consider extra piping lengths. Refrigerant must be added on site in accordance with the actual piping length. * * 4 : The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side. O O O O O O System safety protection * 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor, High-pressure Sensor, Low pressure sensor, Over-current relay. * 6 : 30m when the height difference between indoor units exceeds 3m. 16 221 60Hz Outdoor unit (60Hz) Equivalent HP Model name MMY- Heat Pump Equivalent to 5HP Equivalent to 6HP Equivalent to 8HP Equivalent to 10HP Equivalent to 12HP MAP0501HT7 MAP0601HT7 MAP0801HT7 MAP1001HT7 MAP1201HT7 Inverter unit Outdoor unit type * Cooling capacity ( 1) * Standard heating capacity ( 1) * Power supply ( 2) Running current 16.0 22.4 28.0 33.5 16.0 18.0 25.0 31.5 37.5 (A) 6.16 7.66 9.07 12.16 19.27 (kW) 3.65 4.64 5.67 7.68 11.92 (%) 90 92 95 96 94 EER (Energy Efficiency Ratio) (kW/kW) 3.84 3.45 3.95 3.65 2.81 Starting current (A) 1.0 1.0 1.0 1.0 1.0 Cooling Power factor * 14.0 (kW) 3 phase 60Hz 380V Power consumption Electrical characteristics ( 1) (kW) Running current (A) 6.41 7.45 9.40 12.61 16.47 (kW) 3.84 4.56 5.88 7.97 10.19 (%) 91 93 95 96 94 EER (Energy Efficiency Ratio) (kW/kW) 4.17 3.95 4.25 3.95 3.68 (A) 1.0 1.0 1.0 1.0 1.0 Power consumption Heating Power factor Starting current (mm) External dimension Height 1,800 x Width 990 x Depth 750 (kg) Total weight 228 258 Silky shade (Munsell 1Y8.5/0.5) Colour Compressor Hermetic type Type (kW) Motor output 1.1 x 2 1.4 x 2 Fan unit Motor output 9,000 9,900 Heat exchanger * High-pressure switch (kg) R410A (8.5) ON : 3.73 * ( 5) Gas side (mm) Liquid side (mm) Balance pipe (mm) Gas side * 10,500 R410A (12.5) OFF : 2.90 (MPa) Protective devices Refrigerant piping specifications ( 4) 4.2 x 2 Finned tube Refrigerant R410A(Charged refrigerant amount) ( 3) Connecting method 3.1 x 2 0.60 (kW) (m3/h) Air volume Connecting port dia 2.3 x 2 Propeller fan Fan O / 15.9 O / 19.1 O / 22.2 O / 9.5 O / 28.6 O / 12.7 O / 9.5 Flare Brazing Flare Liquid side Flare Balance pipe Max. equivalent length (m) 175 Max. real length (m) 150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.) Max. total pipe length (Real length) (m) Max. height difference 300 Outdoor unit is higher than indoor unit : 50 (m) * Outdoor unit is lower than indoor unit : 40 ( 6) Shield wire 1.25mm2 x 2 cores. up to 2000m Control wiring When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and (Shield wire) 2.0mm2 x 2 cores. up to 2000m Central remote controller Max. No. of connected indoor units Sound pressure level * 1 : Rated conditions (dB(A)) 8 10 13 16 20 55 56 57 58 59 Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height. + 10%. * 2 : The source voltage must not fluctuate more than 3 : The amount does not consider extra piping lengths. Refrigerant must be added on site in accordance with the actual piping length. * 4 : The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side. * O O O System safety protection 16 222 O O O * 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor, High-pressure Sensor, Low pressure sensor, Over-current relay. 6 : * 30m when the height difference between indoor units exceeds 3m. 60Hz Outdoor unit (Combination) (60Hz) Equivalent HP Set Model name Outdoor unit type Outdoor unit type Heat Pump MMY- Equivalent to 14HP Equivalent to 16HP Equivalent to 18HP Equivalent to 20HP AP1401HT7 AP1601HT7 AP1801HT7 AP2001HT7 Inverter Heat Pump * MMY- MAP0801HT7 MAP0601HT7 MAP0801HT7 MAP0801HT7 MAP1001HT7 MAP0801HT7 MAP1001HT7 MAP1001HT7 (kW) 38.4 45 50.4 56.0 Rated cooling capacity ( 1) * (kW) Standard heating capacity ( 1) Power supply ( 2) (A) Running current Power consumption (kW) Power factor (%) Cooling EER (kW/kW) (Energy Efficiency Ratio) Electrical (A) Starting current characteristics (A) Running current ( 1) * * 43.0 (%) Power factor (kW/kW) EER (Energy Efficiency Ratio) Starting current Compressor Type Motor output (A) 19.51 12.20 22.41 14.16 25.59 16.17 94 95 96 96 3.45 3.69 3.56 3.46 1.0 17.72 1.0 19.64 1.0 22.74 1.0 26.05 10.96 94 12.28 95 14.37 96 16.46 96 3.92 4.07 3.93 3.83 1.0 1.0 1.0 1.0 Height 1,800 x Width 990 x Depth 750 (kg) 258 228 (kW) 2.3 x 2 1.4 x 2 258 258 258 258 Silky shade (Munsell 1Y8.5/0.5) Hermetic type 2.3 x 2 3.1 x 2 2.3 x 2 Fan (kW) Motor output (m3/h) Air volume Heat exchanger Refrigerant R410A Charged amount ( 3) (kg) High-pressure switch (MPa) * 258 3.1 x 2 0.6 9,900 9,000 12.5 8.5 9,900 10,500 Finned tube 9,900 10,5000 12.5 OFF : 2.90 ON : 3.73 * ( 5) Protective devices Gas side * 258 Propeller fan Fan unit Refrigerant pipe spec. ( 4) 63.0 17.97 11.12 (mm) External dimension Total weight Colour 56.5 3 phase 60Hz 380V Power consumption (kW) Heating 50.0 Connecting Liquid side port dia. Balance side Gas side Connecting Liquid side method Balance side (mm) O / 22.2 O / 19.1 (mm) O / 12.7 O / 9.5 O / 22.2 O / 12.7 (mm) O / 9.5 Brazing Flare Flare Max. equivalent length (m) 175 Max. real length Max. total pipe length (Real length) (m) 150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.) Max. height difference (m) (m) Control wiring Central remote controller Max. No. of connected indoor units Sound pressure level * 1 : Rated conditions (dB(A)) 300 Outdoor unit is higher than indoor unit : 50 * Outdoor unit is lower than indoor unit : 40 ( 6) Shield wire 1.25mm2 x 2 cores. up to 2000m When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and (Shield wire) 2.0mm2 x 2 cores. up to 2000m 23 27 30 33 59.5 60 60.5 61 Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height. + 10%. * 2 : The source voltage must not fluctuate more than 3 : The amount does not consider extra piping lengths. Refrigerant must be added on site in accordance with the actual piping length. * 4 : The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side. * O O O O O O System safety protection * 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor, High-pressure Sensor, Low pressure sensor, Over-current relay. 6 : * 30m when the height difference between indoor units exceeds 3m. 16 223 60Hz Equivalent HP Equivalent to 22HP Set Model name Outdoor unit type Outdoor unit model Heat Pump MMY- Inverter MMY(kW) Heat Pump * Rated cooling capacity ( 1) Standard heating capacity ( 1) * Power supply ( 2) Electrical characteristics ( 1) * * MAP1001HT7 3.54 3.01 1.0 27.75 17.35 1.0 29.88 18.68 95 3.98 3.69 1.0 1.0 Height 1,800 x Width 990 x Depth 750 258 258 228 Silky shade (Munsell 1Y8.5/0.5) Type Motor output Fan (kW) 2.3 x 2 Motor output Air volume (kW) (m3/h) 9,900 * 20.41 95 (A) (mm) (kg) 32.64 17.39 (A) Starting current (A) Running current Power consumption (kW) (%) Power factor Heating EER (kW/kW) (Energy Efficiency Ratio) Heat exchanger Refrigerant R410A Charged amount ( 3) (kg) (MPa) High-pressure switch Protective devices (mm) Gas side Connecting (mm) Liquid side port dia. Balance side (mm) * MAP1201HT7 27.81 Power factor (%) Cooling (kW/kW) EER (Energy Efficiency Ratio) Total weight Colour Refrigerant pipe spec. ( 4) MAP0601HT7 61.5 69.0 3 phase 60Hz 380V (A) Running current Power consumption (kW) External dimension Fan unit MAP0801HT7 MAP0801HT7 (kW) Starting current Compressor AP2211HT7 AP2201HT7 Hermetic type 1.4 x 2 Propeller fan 12.5 0.6 9,000 Finned tube 8.5 O / 22.2 OFF : 2.90 ON : 3.73 ( 5) O / 19.1 O / 12.7 O / 9.5 258 258 4.2 x 2 3.1 x 2 10,500 12.5 * O / 28.6 O / 22.2 O / 12.7 O / 9.5 Brazing Flare Gas side Connecting Liquid side method Balance side Flare Max. equivalent length (m) 175 Max. real length Max. total pipe length (Real length) (m) 150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.) (m) 300 Max. height difference (m) Control wiring Max. No. of connected indoor units * 1 : Rated conditions * Shield wire 1.25mm2 x 2 cores. up to 2000m When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and (Shield wire) 2.0mm2 x 2 cores. up to 2000m 37 Central remote controller Sound pressure level Outdoor unit is higher than indoor unit : 50 Outdoor unit is lower than indoor unit : 40 ( 6) (dB(A)) 61.5 Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height. + 10%. * 2 : The source voltage must not fluctuate more than 3 : The amount does not consider extra piping lengths. Refrigerant must be added on site in accordance with the actual piping length. * * 4 : The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side. O O O System safety protection O O O * 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor, 16 224 High-pressure Sensor, Low pressure sensor, Over-current relay. * 6 : 30m when the height difference between indoor units exceeds 3m. 60Hz Equivalent HP Set Model name Outdoor unit type Equivalent to 24HP MMY- Heat Pump Inverter MMY- Outdoor unit model Heat Pump Rated cooling capacity ( 1) * * Standard heating capacity ( 1) Power supply ( 2) Running current * Electrical characteristics ( 1) MAP0801HT7 MAP1201HT7 3 phase 60Hz 380V 40.02 18.44 96 25.02 95 3.69 2.72 1.0 1.0 Running current (A) Power consumption (kW) Power factor (%) 29.43 18.79 97 33.74 21.32 96 4.07 3.59 1.0 1.0 EER (kW/kW) (Energy Efficiency Ratio) (A) Starting current (mm) (kg) Total weight Colour Height 1,800 x Width 990 x Depth 750 258 258 258 258 258 Silky shade (Munsell 1Y8.5/0.5) Hermetic type Type Motor output Fan (kW) Motor output Air volume (kW) (m3/h) 2.3 x 2 4.2 x 2 Propeller fan 0.6 9,900 10,500 Finned tube 12.5 Heat exchanger Refrigerant R410A Charged amount ( 3) (kg) High-pressure switch (MPa) * OFF : 2.90 ON : 3.73 ( 5) Protective devices Gas side Connecting Liquid side port dia. Balance side * MAP1201HT7 Power consumption (kW) Power factor (%) Cooling (kW/kW) EER (Energy Efficiency Ratio) Starting current (A) External dimension Refrigerant pipe spec. ( 4) MAP0801HT7 68.0 76.5 29.19 Heating Fan unit MAP0801HT7 (kW) (kW) (A) * Compressor AP2411HT7 AP2401HT7 (mm) (mm) O / 22.2 * O / 28.6 O / 12.7 O / 9.5 (mm) Brazing Flare Gas side Connecting Liquid side method Balance side Max. equivalent length (m) Flare 175 Max. real length (m) 150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.) Max. total pipe length (Real length) (m) 300 Max. height difference (m) Control wiring Central remote controller Outdoor unit is higher than indoor unit : 50 * Outdoor unit is lower than indoor unit : 40 ( 6) Shield wire 1.25mm2 x 2 cores. up to 2000m When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and (Shield wire) 2.0mm2 x 2 cores. up to 2000m Max. No. of connected indoor units Sound pressure level * 1 : Rated conditions 40 62 (dB(A)) Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height. + 10%. * 2 : The source voltage must not fluctuate more than * 3 : The amount does not consider extra piping lengths. Refrigerant must be added on site in accordance with the actual piping length. * 4 : The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side. O O O O O O System safety protection * 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor, High-pressure Sensor, Low pressure sensor, Over-current relay. * 6 : 30m when the height difference between indoor units exceeds 3m. 16 225 60Hz Equivalent HP Set Model name Outdoor unit type * Cooling Electrical characteristics ( 1) Equivalent to 30HP AP2801HT7 Inverter AP3001HT7 (kW) 81.5 (A) Running current Power consumption (kW) 32.11 20.29 Standard heating capacity ( 1) Power supply ( 2) * Equivalent to 28HP AP2601HT7 MMY- MAP1001HT7 MAP0801HT7 MAP0801HT7 MAP1001HT7 MAP1001HT7 MAP0801HT7 MAP1001HT7 MAP1001HT7 MAP1001HT7 (kW) 73 78.5 84.0 Outdoor unit model Heat Pump Rated cooling capacity ( 1) * Equivalent to 26HP MMY- Heat Pump (%) Power factor EER (kW/kW) (Energy Efficiency Ratio) Starting current (A) (%) Heating Power factor EER (kW/kW) (Energy Efficiency Ratio) Starting current External dimension Total weight (A) (mm) (kg) Fan unit 1.0 1.0 32.80 20.51 35.77 22.60 38.88 24.82 95 96 97 3.97 3.89 3.83 1.0 Height 1,800 x Width 990 x Depth 750 258 258 258 258 1.0 258 258 Motor output 2.3 x 2 (kW) Fan Motor output (kW) (m3/h) * 9,900 10,500 258 258 258 3.1 x 2 Propeller fan 0.6 2.3 x 2 3.1 x 2 10,500 9,900 10,500 Finned tube 12.5 Refrigerant R410A Charged amount ( 3) (kg) * 1.0 Silky shade (Munsell 1Y8.5/0.5) Hermetic type Air volume Heat exchanger Refrigerant pipe spec. ( 4) 3.46 3.52 1.0 Type High-pressure switch Protective devices 38.40 24.26 3.60 Colour Compressor 95.0 96 (A) Running current Power consumption (kW) * 88.0 3 phase 60Hz 380V 35.25 22.27 OFF : 2.90 ON : 3.73 ( 5) (MPa) * O / 22.2 (mm) Gas side Connecting Liquid side (mm) port dia. Balance side (mm) Gas side Connecting Liquid side method Balance side O / 12.7 O / 9.5 Brazing Flare Max. equivalent length (m) Flare 175 Max. real length (m) 150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.) Max. total pipe length (Real length) (m) Max. height difference (m) Control wiring Max. No. of connected indoor units * 1 : Rated conditions * Outdoor unit is lower than indoor unit : 40 ( 6) Shield wire 1.25mm2 x 2 cores. up to 2000m When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and (Shield wire) 2.0mm2 x 2 cores. up to 2000m Central remote controller Sound pressure level 300 Outdoor unit is higher than indoor unit : 50 (dB(A)) 43 62 47 62.5 48 63 Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height. + 10%. * 2 : The source voltage must not fluctuate more than * 3 : The amount does not consider extra piping lengths. Refrigerant must be added on site in accordance with the actual piping length. * 4 : The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side. O O O System safety protection O O O * 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor, 16 226 High-pressure Sensor, Low pressure sensor, Over-current relay. * 6 : 30m when the height difference between indoor units exceeds 3m. 60Hz Equivalent to 32HP Equivalent HP Set Model name Outdoor unit type Heat Pump Outdoor unit model Heat Pump MMY- Inverter * MMY- MAP0801HT7 MAP0801HT7 MAP0801HT7 MAP0801HT7 MAP1201HT7 MAP1001HT7 MAP1001HT7 (kW) 90.0 Rated cooling capacity ( 1) * Standard heating capacity ( 1) Power supply ( 2) * Cooling Electrical characteristics ( 1) (kW) 100.0 3 phase 60Hz 380V 39.04 45.34 24.41 95 28.65 96 (kW/kW) EER (Energy Efficiency Ratio) 3.69 3.14 Starting current 1.0 1.0 39.28 24.56 42.83 26.78 95 95 4.07 3.73 Running current Power consumption (A) (kW) (%) Power factor Running current Power consumption * (A) (A) (kW) (%) Heating Power factor (kW/kW) EER (Energy Efficiency Ratio) Starting current External dimension Total weight 1.0 (A) (mm) (kg) 1.0 Height 1,800 x Width 990 x Depth 750 258 258 258 Fan unit Type (kW) Motor output 2.3 x 2 (kW) 258 4.2 x 2 258 3.1 x 2 0.6 10,500 9,900 (m3/h) Finned tube * 12.5 (kg) Refrigerant R410A Charged amount ( 3) High-pressure switch (MPa) Protective devices Gas side Connecting Liquid side port dia. Balance side OFF : 2.90 ON : 3.73 ( 5) O / 22.2 (mm) * (mm) O / 12.7 (mm) O / 9.5 Brazing Gas side * 258 Propeller fan Fan Motor output Air volume Heat exchanger Refrigerant pipe spec. ( 4) 258 Silky shade (Munsell 1Y8.5/0.5) Hermetic type Colour Compressor AP3211HT7 AP3201HT7 O / 28.6 O / 22.2 Connecting Liquid side method Balance side Max. equivalent length (m) Flare 175 Max. real length (m) 150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.) Max. total pipe length (Real length) (m) Max. height difference Flare (m) Control wiring Central remote controller 300 Outdoor unit is higher than indoor unit : 50 * Outdoor unit is lower than indoor unit : 40 ( 6) Shield wire 1.25mm2 x 2 cores. up to 2000m When connecting to outdoor unit : MVVS (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and MVVS (Shield wire) 2.0mm2 x 2 cores. up to 2000m Max. No. of connected indoor units Sound pressure level * 1 : Rated conditions 48 (dB(A)) 63 Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height. + 10%. * 2 : The source voltage must not fluctuate more than * 3 : The amount does not consider extra piping lengths. Refrigerant must be added on site in accordance with the actual piping length. * 4 : The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side. O O O O O O System safety protection * 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor, High-pressure Sensor, Low pressure sensor, Over-current relay. * 6 : 30m when the height difference between indoor units exceeds 3m. 16 227 60Hz Equivalent HP Equivalent to 34HP Set Model name Outdoor unit type Outdoor unit model MMY- Heat Pump Inverter MMY- MAP1001HT7 MAP0801HT7 MAP0801HT7 MAP0801HT7 MAP1201HT7 MAP1201HT7 MAP1001HT7 96.0 (kW) Heat Pump * Rated cooling capacity ( 1) * * * (A) Running current Power consumption (kW) (%) Power factor Cooling EER (kW/kW) (Energy Efficiency Ratio) 41.99 26.53 Starting current (A) (A) Power consumption (kW) (%) Heating Power factor (kW/kW) EER (Energy Efficiency Ratio) (A) Starting current Running current External dimension Fan unit 258 Type Motor output Fan (kW) 3.1 x 2 Motor output Air volume (kW) (m3/h) Heat exchanger Refrigerant R410A Charged amount ( 3) * High-pressure switch 52.91 96 33.08 95 3.62 2.90 1.0 42.34 1.0 46.75 27.03 97 29.54 96 4.00 3.66 1.0 (mm) (kg) Total weight Colour Compressor 108.0 3 phase 60Hz 380V (kW) Standard heating capacity ( 1) Power supply ( 2) Electrical characteristics ( 1) 1.0 Height 1,800 x Width 990 x Depth 750 258 258 258 Silky shade (Munsell 1Y8.5/0.5) Hermetic type 258 2.3 x 2 Gas side * Connecting Liquid side port dia. Balance side Gas side Connecting Liquid side method Balance side 258 258 4.2 x 2 3.1 x 2 10,500 9,900 O / 28.6 O / 22.2 Propeller fan 0.6 9,900 10,500 Finned tube 12.5 (kg) (MPa) OFF : 2.90 ON : 3.73 ( 5) Protective devices Refrigerant pipe spec. ( 4) AP3411HT7 AP3401HT7 (mm) O / 22.2 * (mm) O / 12.7 (mm) O / 9.5 Brazing Flare Flare Max. equivalent length (m) 175 Max. real length Max. total pipe length (Real length) (m) 150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.) Max. height difference (m) 300 Outdoor unit is higher than indoor unit : 50 (m) * Outdoor unit is lower than indoor unit : 40 ( 6) Shield wire 1.25mm2 x 2 cores. up to 2000m Control wiring When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and (Shield wire) 2.0mm2 x 2 cores. up to 2000m 48 Central remote controller Max. No. of connected indoor units Sound pressure level * 1 : Rated conditions (dB(A)) 63.5 63.5 Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height. + 10%. * 2 : The source voltage must not fluctuate more than 3 : The amount does not consider extra piping lengths. Refrigerant must be added on site in accordance with the actual piping length. * 4 : The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side. * O O O System safety protection O O O * 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor, 16 228 High-pressure Sensor, Low pressure sensor, Over-current relay. 6 : * 30m when the height difference between indoor units exceeds 3m. 60Hz Equivalent HP Equivalent to 36HP Set Model name Outdoor unit type Outdoor unit model Heat Pump MMY- Inverter Heat Pump * MMY- MAP1001HT7 MAP1001HT7 MAP0801HT7 MAP0801HT7 MAP1201HT7 MAP1201HT7 MAP1201HT7 101.0 (kW) Rated cooling capacity ( 1) * Standard heating capacity ( 1) Power supply ( 2) * Cooling Electrical characteristics ( 1) 113.0 3 phase 60Hz 380V (kW) Running current (A) Power consumption (kW) (%) 44.92 28.38 60.06 37.16 96 94 (kW/kW) EER (Energy Efficiency Ratio) 3.56 2.72 Starting current 1.0 1.0 45.49 28.74 50.90 31.49 96 94 3.93 3.59 Power factor (A) Running current (A) Power consumption (kW) * (%) Heating Power factor (kW/kW) EER (Energy Efficiency Ratio) Starting current External dimension Total weight (A) (mm) (kg) 1.0 1.0 Height 1,800 x Width 990 x Depth 750 258 258 258 Fan unit Type (kW) Motor output Fan Motor output * Refrigerant R410A Charged amount ( 3) Refrigerant pipe spec. ( 4) * Gas side Connecting Liquid side port dia. Balance side Gas side Connecting Liquid side method Balance side Max. equivalent length Max. real length Max. total pipe length (Real length) Max. height difference 4.2 x 2 10,500 9,900 Finned tube 10,500 258 12.5 (kg) OFF : 2.90 ON : 3.73 ( 5) O / 22.2 (mm) * (mm) O / 12.7 (mm) O / 9.5 Brazing O / 28.6 Flare (m) Flare 175 (m) 150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.) (m) 300 Outdoor unit is higher than indoor unit : 50 (m) Central remote controller * 1 : Rated conditions 258 2.3 x 2 Propeller fan 0.6 (MPa) Control wiring Max. No. of connected indoor units Sound pressure level 258 3.1 x 2 (kW) (m3/h) Air volume Heat exchanger High-pressure switch Protective devices 258 Silky shade (Munsell 1Y8.5/0.5) Hermetic type Colour Compressor AP3611HT7 AP3601HT7 (dB(A)) * Outdoor unit is lower than indoor unit : 40 ( 6) Shield wire 1.25mm2 x 2 cores. up to 2000m When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and (Shield wire) 2.0mm2 x 2 cores. up to 2000m 48 64 63.5 Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height. + 10%. * 2 : The source voltage must not fluctuate more than * 3 : The amount does not consider extra piping lengths. Refrigerant must be added on site in accordance with the actual piping length. * 4 : The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side. O O O O O O System safety protection * 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor, High-pressure Sensor, Low pressure sensor, Over-current relay. * 6 : 30m when the height difference between indoor units exceeds 3m. 16 229 60Hz Equivalent to 38HP Equivalent HP Set Model name Outdoor unit type Heat Pump MMY- * MMY- MAP1001HT7 MAP1001HT7 MAP1001HT7 MAP0801HT7 MAP1001HT7 MAP1001HT7 MAP1001HT7 MAP1001HT7 (kW) 112.0 106.5 * Standard heating capacity ( 1) Power supply ( 2) Running current Power consumption * Electrical characteristics ( 1) * Power factor Fan unit (A) (kW) (%) 51.18 32.34 48.05 30.36 96 1.0 1.0 48.79 30.83 52.31 33.05 (A) (A) (kW) 3.46 (%) 96 EER (kW/kW) (Energy Efficiency Ratio) (A) Starting current (mm) (kg) 3.83 3.88 1.0 1.0 Height 1,800 x Width 990 x Depth 750 258 258 258 258 258 258 258 258 Silky shade (Munsell 1Y8.5/0.5) Hermetic type Type Motor output Fan (kW) (m3/h) * High-pressure switch Protective devices Gas side Connecting Liquid side port dia. Balance side Gas side Connecting Liquid side method Balance side Max. equivalent length Max. real length Max. total pipe length (Real length) Max. height difference 3.1 x 2 2.3 x 2 Propeller fan 10,500 9,900 Finned tube (kW) Motor output Refrigerant R410A Charged amount ( 3) * 3 phase 60Hz 380V 3.51 Air volume Heat exchanger Refrigerant pipe spec. ( 4) 126.5 119.5 Starting current Total weight Colour Compressor (kW) EER (kW/kW) (Energy Efficiency Ratio) Running current Power consumption Heating Power factor External dimension AP4001HT7 Inverter Heat Pump Outdoor unit model Rated cooling capacity ( 1) Cooling Equivalent to 40HP AP3801HT7 0.6 (kg) 12.5 OFF : 2.90 ON : 3.73 ( 5) (mm) O / 22.2 (mm) (mm) O / 12.7 * O / 9.5 Brazing Flare Flare (m) 175 (m) 150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.) (m) 300 (m) Outdoor unit is higher than indoor unit : 50 Outdoor unit is lower than indoor unit : 40 ( 6) * Shield wire 1.25mm2 x 2 cores. up to 2000m When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and (Shield wire) 2.0mm2 x 2 cores. up to 2000m Central remote controller Max. No. of connected indoor units * 1 : Rated conditions 10,500 (MPa) Control wiring Sound pressure level 3.1 x 2 48 64 (dB(A)) Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height. + 10%. * 2 : The source voltage must not fluctuate more than 3 : The amount does not consider extra piping lengths. Refrigerant must be added on site in accordance with the actual piping length. * 4 : The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side. * O O O System safety protection O O O * 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor, 16 230 High-pressure Sensor, Low pressure sensor, Over-current relay. 6 : * 30m when the height difference between indoor units exceeds 3m. 60Hz Equivalent to 44HP Equivalent to 42HP Equivalent HP Set Model name Outdoor unit type Heat Pump Outdoor unit model Heat Pump MMY- AP4401HT7 AP4201HT7 Inverter MMY- MAP1201HT7 MAP1001HT7 MAP1001HT7 MAP1001HT7 MAP1201HT7 MAP1201HT7 MAP1001HT7 MAP1001HT7 (kW) 123.5 118.0 (kW) 138.0 132.0 3 phase 60Hz 380V 60.56 58.15 Running current (A) Power consumption (kW) 40.99 36.74 * Rated cooling capacity ( 1) Standard heating capacity ( 1) Power supply ( 2) * Cooling * (%) Power factor (kW/kW) EER (Energy Efficiency Ratio) Electrical Starting current (A) characteristics Running current (A) ( 1) Power consumption (kW) (%) Heating Power factor EER (kW/kW) (Energy Efficiency Ratio) Starting current (A) * External dimension Compressor Fan unit Type Motor output Fan Motor output Air volume 95 3.01 1.0 1.0 56.20 35.14 59.75 37.36 95 3.76 3.69 1.0 (mm) Total weight Colour 96 3.21 1.0 Height 1,800 x Width 990 x Depth 750 (kg) 258 (kW) 4.2 x 2 258 258 258 (kW) (m3/h) * Connecting Liquid side port dia. Balance side (mm) 3.1 x 2 12.5 OFF : 2.90 ON : 3.73 ( 5) Protective devices Gas side 4.2 x 2 Propeller fan 0.6 10,500 Finned tube (kg) Refrigerant R410A Charged amount ( 3) High-pressure switch (MPa) * 258 Hermetic type 3.1 x 2 Heat exchanger Refrigerant pipe spec. ( 4) 258 258 258 Silky shade (Munsell 1Y8.5/0.5) O / 28.6 O / 22.2 (mm) (mm) * O / 28.6 O / 22.2 O / 12.7 O / 9.5 Brazing Flare Gas side Connecting Liquid side method Balance side Flare Max. equivalent length (m) 175 Max. real length (m) 150 (If the total bend length exceeds 150m, use the max equivalent length as the standard.) Max. total pipe length (Real length) (m) 300 (m) Outdoor unit is higher than indoor unit : 50 Outdoor unit is lower than indoor unit : 40 ( 6) Max. height difference Control wiring Central remote controller Max. No. of connected indoor units Sound pressure level * 1 : Rated conditions * Shield wire 1.25mm2 x 2 cores. up to 2000m When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and (Shield wire) 2.0mm2 x 2 cores. up to 2000m 48 64.5 (dB(A)) Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height. + 10%. * 2 : The source voltage must not fluctuate more than 3 : The amount does not consider extra piping lengths. Refrigerant must be added on site in accordance with the actual piping length. * 4 : The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side. * O O O O O O System safety protection * 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor, High-pressure Sensor, Low pressure sensor, Over-current relay. 6 : * 30m when the height difference between indoor units exceeds 3m. 16 231 60Hz Equivalent HP Set Model name Outdoor unit type Outdoor unit model Equivalent to 46HP Heat Pump MMY- Equivalent to 48HP AP4601HT7 AP4801HT7 Inverter Heat Pump Rated cooling capacity ( 1) MMY- MAP1201HT7 MAP1201HT7 MAP1201HT7 MAP1001HT7 MAP1201HT7 MAP1201HT7 MAP1201HT7 MAP1201HT7 (kW) 135.0 130.0 Standard heating capacity ( 1) (kW) 150.0 145 Power supply ( 2) 3 phase 60Hz 380V Running current (A) 72.92 79.44 Power consumption (kW) 45.59 49.67 (%) Power factor 95 Cooling * * * Electrical characteristics ( 1) * (kW/kW) EER (Energy Efficiency Ratio) 2.85 (A) 1.0 1.0 63.73 39.85 95 67.56 41.80 94 3.64 3.59 Starting current (A) Power consumption (kW) Power factor (%) Heating (kW/kW) EER (Energy Efficiency Ratio) Running current Starting current External dimension (A) (mm) (kg) Total weight 2.72 1.0 1.0 Height 1,800 x Width 990 x Depth 750 258 258 258 Colour Compressor Fan unit Type (kW) Motor output Fan Motor output Air volume Heat exchanger * Refrigerant R410A Charged amount ( 3) High-pressure switch Protective devices Gas side Connecting Liquid side port dia. Balance side 3.1 x 2 Propeller fan 4.2 x 2 (kW) 0.6 (m3/h) 10,500 Finned tube (kg) (mm) * 258 258 4.2 x 2 12.5 (MPa) OFF : 2.90 ON : 3.73 ( 5) O / 28.6 O / 22.2 * O / 28.6 O / 12.7 (mm) (mm) O / 9.5 Brazing Gas side Refrigerant pipe spec. ( 4) 258 258 258 Silky shade (Munsell 1Y8.5/0.5) Hermetic type Connecting Liquid side method Balance side Flare Flare Max. equivalent length (m) 160 Max. real length Max. total pipe length (Real length) (m) 135 (If the total bend length exceeds 135m, use the max equivalent length as the standard.) Max. height difference (m) 300 (m) Outdoor unit is higher than indoor unit : 50 Outdoor unit is lower than indoor unit : 40 ( 6) * Shield wire 1.25mm2 x 2 cores. up to 2000m When connecting to outdoor unit : (Shield wire) 1.25mm2 x 2 cores. up to 1000m, and (Shield wire) 2.0mm2 x 2 cores. up to 2000m Control wiring Central remote controller 48 Max. No. of connected indoor units Sound pressure level * 1 : Rated conditions (dB(A)) 65 Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20 C DB, Outdoor air temperature 7 C DB/6 C WB The standard piping means that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height. + 10%. * 2 : The source voltage must not fluctuate more than 3 : The amount does not consider extra piping lengths. Refrigerant must be added on site in accordance with the actual piping length. * 4 : The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side. * O O O System safety protection O O O * 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure Switch, Over-current sensor, 16 232 High-pressure Sensor, Low pressure sensor, Over-current relay. 6 : * 30m when the height difference between indoor units exceeds 3m. Oct. 05’ Engineering Data High Wall Type ( 2 Series ) Indoor Unit MMK-AP0072H MMK-AP0092H MMK-AP0122H 1. Equipments 2. Technical Specifications 3. Dimensional Drawing 4. Wiring Diagram 5. Refrigerant Cycle Diagram 6. Sensible Capacity Table 7. Fan characteristics 8. Sound Characteristics (NC curve) 9. Wireless Remote controller A-1 A-2 1. Equipment 1-1. Line up Type Appearance High Wall type (2 series) MMK-AP0072H 007 type 0.8 2.2 2.5 MMK-AP0092H 009 type 1.0 2.8 3.2 MMK-AP0122H 012 type 1.25 3.6 4.0 Appearance (Packed with the indoor unit) Application Function Start / Stop Changing mode Temperature setting Air flow changing (5 step) Clock Timer function - ON/OFF timer (10 min. step) - Daily timer High power mode ECO mode (Sleep timer with ECO-logic) One-touch pre-set memory One-touch Auto (*1) WH-H2UE Wireless remote controller Model name Cooling Heating Capacity (kW) Capacity (kW) Capacity rank 1-2. Remote controller Name Capacity code Model Name (Note.1) Super MMS can not accept “AUTO” mode, Super HRM can accept “AUTO” mode. 1-3. Wiring Design Model Nominal Voltage 50Hz Voltage Fan Motor Power Supply (V-Ph-Hz) Min Max kW FLA MCA MOCP MMK-AP0072H 230-1-50 198 264 0.03 0.20 0.24 15 MMK-AP0092H 230-1-50 198 264 0.03 0.21 0.26 15 MMK-AP0122H 230-1-50 198 264 0.03 0.22 0.27 15 Legend MCA MOCP : Minimum Circuit Amps : Maximum Overcurrent Protection (Amps) FLA kW : Full Load Amps : Fan Motor Rated Output (kW) 1-4. Accessories Accessory parts name Model Remarks Wired remote controller RBC-AMT31E Simple remote controller RBC-AS21E2 Wireless remote controller kit TCB-AX21E2 with separated receiver unit Central remote controller TCB-SC642TLE2 Max. 64 group / unit Weekly timer RBC-EXW21E2 Use with RBC-AMT31E A-31 2. Technical Specifications 50Hz High Wall type (2 Series) Model name MMK- Cooling / Heating capacity (Note 1) (kW) Electrical Running current Characteristics Power consumption Starting current Outer dimension AP0092H AP0122H 2.2 / 2.5 2.8 / 3.2 3.6 / 4.0 1 phase 50Hz 230V (220-240V) (Power exclusive for indoor is required.) Power Supply Appearance AP0072H (A) 0.17 0.18 0.19 (kW) 0.017 0.018 0.019 (A) 0.22 0.23 0.24 Suction grille and side panel Moon white Discharge grille Moon white Bottom surface Moon white Height x Width x Depth Total weight (mm) 275 x 790 x 208 (kg) 11 Heat exchanger Finned tube Soundproof/Heat-insulating material Non-flammable insulation Cross-flow fan Fan Fan unit Standard air flow (High/Mid/Low)(m3/h) 480 / 420 /360 Motor 30 Air filter Standard filter attached (Simple filter) Controller Connecting pipe (Note 3) Gas side Liquid side Drain port Sound level (Note 2) (High / Mid / Low) 2 A-4 510 / 450 / 360 540 / 450 / 360 Note 1 : Note 2 : Note 3 : Note 4 : Wireless remote controller (WH-H2UE, Packed with indoor unit) 9.5 (mm) 6.4 (mm) 16 (Polyvinyl chloride tube) (Outer dia.) (dB(A)) 35-32-29 36-33-29 37-33-29 The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height. The sound level are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Wireless remote controller is packed with indoor unit. Wired remote controller (RBC-AMT31E,RBC-AS21E2) can be also connected. Rated conditions Cooling : Indoor air temperature 27 C DB/19 C WB, Outdoor air temperature 35 C DB Heating : Indoor air temperature 20C DB, Outdoor air temperature 7C DB/6C WB 3. Dimensional Drawing Model : MMK-AP0072H, AP0092H, AP0122H Air inlet port 790 275 275 208 275 208 Knockout 60 48 Air outlet port 6 6 60 48 Knockout 54.5 60 60 48 48 208 790 54.5 790 275 Wired remote controller RBC-AMT21E RBC-AMT31E Simple wired remote controller RBC-AS21E RBC-AS21E2 Wireless remote controller kit RBC-AX22CE RBC-AX22CE2 208 790 Tab for insulation plate Refrigerant pipe connecting port Gas side O9.5 321 Drain pipe Refrigerant pipe connecting port Liquid side O6.4 (Installation space) 100mm or more 170mm or more 170mm or more *300mm or more *(For attached Flow Selector unit when used in heat recovery model) Note : All dimensions are in mm. A-53 4. Wiring Diagram Model : MMK-AP0072H, AP0092H, AP0122H 4 A-6 5. Refrigerant Cycle Diagram Model : MMK-AP0072H, AP0092H, AP0122H Liquid side Gas side Strainer Capillary tube Air heat exchanger at indoor side Pulse Motor Valve (PMV) Sensor (TC2) Sensor (TCJ) Fan Sensor (TC1) Sensor (TA) Functional part name Fan motor Functional outline Pulse Motor Valve (PMV) PMV (Connector CN082 (6P): Blue) 1) Controls super heat in cooling operation 2) Controls under cool in heating operation 3) Recovers refrigerant oil in cooling operation 4) Recovers refrigerant oil in heating operation Temp. sensor 1.TA (Connector CN104 (2P): Yellow) 1) Detects indoor suction temperature 2.TC1 (Connector CN100 (3P): Brown) 1) Controls PMV super heat in cooling operation 3.TC2 (Connector CN101 (2P): Black 1) Controls PMV under cool in heating operation 4.TCJ (Connector CN102 (2P): Red) 1) Controls PMV super heat in cooling operation A-75 6. Sensible Capacity Table High Wall Type ( MMK-AP****2H ) 2 series TC: Total capacity [kW] SHC: Sensible capacity [kW] Indoor Air Temp. unit outdoor size air temp. 007 009 012 6 A-8 14.0CWB 16.0CWB 18.0CWB 19.0CWB 20.0CWB 22.0CWB 20CDB 23CDB 26CDB 27CDB 28CDB 30CDB 24.0CWB 32CDB CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC 10.0 1.8 1.5 2.0 1.6 2.1 1.7 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 12.0 1.8 1.5 2.0 1.6 2.1 1.7 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 14.0 1.8 1.5 2.0 1.6 2.1 1.7 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 16.0 1.8 1.5 2.0 1.6 2.1 1.7 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 18.0 1.8 1.5 2.0 1.6 2.1 1.7 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 20.0 1.8 1.5 2.0 1.6 2.1 1.7 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 21.0 1.8 1.5 2.0 1.6 2.1 1.7 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 23.0 1.8 1.5 2.0 1.6 2.1 1.7 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 25.0 1.8 1.5 2.0 1.6 2.1 1.7 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 27.0 1.8 1.5 2.0 1.6 2.1 1.7 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 29.0 1.8 1.5 2.0 1.6 2.1 1.7 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 31.0 1.8 1.5 2.0 1.6 2.1 1.7 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 33.0 1.8 1.5 2.0 1.6 2.1 1.7 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 35.0 1.8 1.5 2.0 1.6 2.1 1.7 2.2 1.7 2.3 1.7 2.4 1.7 2.5 1.6 37.0 1.7 1.5 1.9 1.6 2.1 1.7 2.1 1.6 2.2 1.6 2.3 1.6 2.4 1.6 39.0 1.7 1.4 1.9 1.5 2.0 1.6 2.1 1.6 2.1 1.6 2.3 1.6 2.4 1.5 10.0 2.3 1.8 2.5 1.9 2.7 2.0 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 12.0 2.3 1.8 2.5 1.9 2.7 2.0 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 14.0 2.3 1.8 2.5 1.9 2.7 2.0 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 16.0 2.3 1.8 2.5 1.9 2.7 2.0 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 18.0 2.3 1.8 2.5 1.9 2.7 2.0 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 20.0 2.3 1.8 2.5 1.9 2.7 2.0 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 21.0 2.3 1.8 2.5 1.9 2.7 2.0 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 23.0 2.3 1.8 2.5 1.9 2.7 2.0 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 25.0 2.3 1.8 2.5 1.9 2.7 2.0 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 27.0 2.3 1.8 2.5 1.9 2.7 2.0 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 29.0 2.3 1.8 2.5 1.9 2.7 2.0 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 31.0 2.3 1.8 2.5 1.9 2.7 2.0 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 33.0 2.3 1.8 2.5 1.9 2.7 2.0 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 35.0 2.3 1.8 2.5 1.9 2.7 2.0 2.8 2.0 2.9 2.0 3.1 2.0 3.2 1.9 37.0 2.2 1.7 2.5 1.8 2.6 1.9 2.7 1.9 2.8 1.9 3.0 1.9 3.1 1.9 39.0 2.2 1.7 2.4 1.8 2.6 1.9 2.6 1.9 2.7 1.9 2.9 1.9 3.0 1.8 10.0 3.0 2.2 3.3 2.4 3.5 2.5 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 12.0 3.0 2.2 3.3 2.4 3.5 2.5 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 14.0 3.0 2.2 3.3 2.4 3.5 2.5 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 16.0 3.0 2.2 3.3 2.4 3.5 2.5 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 18.0 3.0 2.2 3.3 2.4 3.5 2.5 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 20.0 3.0 2.2 3.3 2.4 3.5 2.5 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 21.0 3.0 2.2 3.3 2.4 3.5 2.5 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 23.0 3.0 2.2 3.3 2.4 3.5 2.5 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 25.0 3.0 2.2 3.3 2.4 3.5 2.5 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 27.0 3.0 2.2 3.3 2.4 3.5 2.5 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 29.0 3.0 2.2 3.3 2.4 3.5 2.5 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 31.0 3.0 2.2 3.3 2.4 3.5 2.5 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 33.0 3.0 2.2 3.3 2.4 3.5 2.5 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 35.0 3.0 2.2 3.3 2.4 3.5 2.5 3.6 2.5 3.7 2.5 3.9 2.5 4.1 2.4 37.0 2.9 2.1 3.2 2.3 3.4 2.4 3.5 2.4 3.6 2.4 3.8 2.4 4.0 2.3 39.0 2.8 2.1 3.1 2.2 3.3 2.4 3.4 2.4 3.5 2.4 3.7 2.3 3.9 2.3 7. Fan Characteristics Discharge Air Speed and Air Throw High Wall Type (2 series) Model : MMK-AP0072H, AP0092H, AP0122H Horizontal discharge Initial speed High wind : 4.5m/s Med wind : 3.7m/s Low wind : 3.2m/s Air speed (m/s) 5 4 High Mid Low 3 2 1 0 0 1 2 3 4 5 6 7 Horizontal throw (m) A-97 8. Sound Characteristics (NC curve) High Wall Type (2 series) Model : MMK-AP0072H, AP0092H, AP0122H 1m 1m Microphone MMK-AP0072H Fan tap H M L Sound pressure level (dB(A)) 35 32 29 Octave band sound pressure level (dB) 90 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 20 10 20-75 NC-30 Audibility limits of continuous white level 75-150 NC-20 150-300 300-600 600-1200 1200-2400 Octave band frequency (Hz) 8 A-10 2400-4800 4800-10000 MMK-AP0092H Fan tap H M L Sound pressure level (dB(A)) 36 33 29 Octave band sound pressure level (dB) 90 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 20 10 20-75 NC-30 Audibility limits of continuous white level 75-150 NC-20 150-300 300-600 600-1200 1200-2400 2400-4800 4800-10000 Octave band frequency (Hz) MMK-AP0122H Fan tap H M L Sound pressure level (dB(A)) 35 33 29 Octave band sound pressure level (dB) 90 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 20 10 20-75 NC-30 Audibility limits of continuous white level 75-150 NC-20 150-300 300-600 600-1200 1200-2400 2400-4800 4800-10000 Octave band frequency (Hz) A-11 9 9. Wireless Remote controller High wall (1 series) High Wall (2 series) TCB-AX21E2(sold TCB-AX21E (Sold Separately) WH-H2UE External View Function Button Start/Stop Setting temp. Start/Stop Contents Button OK START/STOP Contents OK AUTO 17~27 °C 17~30 °C COOL 18~30 °C 17~30 °C DRY 18~30 °C 17~30 °C 16~26 °C 17~30 °C HEAT Fahrenheit display - Air Volume Control Flap Swing Swing/Frap OK - - 3-Speed, Auto FAN 5-Speed, Auto FIX OK SWING OK MODE Auto,Cool,Dry, Heat, Fan OK Auto, Heat, Dry, Cool, Fan Operation select Remarks No Fahrenheit display function 5-step control No switch setting for cooling only One-touch auto ( Auto mode, One-touch Auto Setting temperature :22 °C, Air volume : Auto, Flap position : Auto, Swing : Off) One-touch Auto - - AUTO Preset mode - - MEMO / PRESET OK Clock - - CLOCK OK OFF timer, ON timer, Clock display Repeat timer, 30 ON/OFF/SET system, minutes interval, 10 minutes interval, max. 72 hours, max. 24 hours, Memorizing of setting contents for preset mode freely. Available for ON / OFF working together ON/OFF timer SET ECONO mode - - ECO OK Sleep timer with ECO logic Daily timer - - ON/OFF/SET OK Setting both ON and OFF timer simultaneously and daily CL OK - - Filter reset Filter reset Reset Reset Timer cancel High Power mode Sensor button SENSOR OK - Hi-POWER OK Automatic controls for quick cooling and heating OK FILTER OK - OK RESET OK - OK - - No remote controller sensor (Note) 1. Automatic operation mode can not be accepted by heat pump system. If transmission is sent as auto mode, operation lamp and timer lamp of the indoor unit will light up with a beep as notification. In this case, change the other operation mode. (Heat recovery system can accept automatic operation by using this wireless remote controller.) 2. Group control using the wired remote controller (WH-H2UE) is not available. If it is incorrect action or display disagreement may occur. 3. A wired remote controller is required for the group control. (sold separately.) 4. When the wired remote controller is connected to this high wall unit, two remote control with the wireless remote controller (WH-H2UE) can be used. In this case, last-push priority control is performed. 5. When the unit is controlled in a group through a wired control, ECO-Timer and Hi-POWER operation will not function. 10 A-12 Oct. 05’ Engineering Data 1-way (2 series) Air Discharge Cassette Type Indoor Unit MMU-AP0152SH MMU-AP0182SH MMU-AP0242SH Contents 1. Specifications 2. Dimensions 3. Electrical current characteristics 4. Sensible capacity table 5. Wiring diagrams 6. Air speed characteristics 7. Sound characteristics (NC Curve) 8. Fresh air intake (Design guide) 9. Barycentric position A-13 A-14 1. Specification 1-way (2 series) Air Discharge Cassette Type 50Hz Model name MMUAP0152SH AP0182SH AP0242SH Cooling/Heating capacity (kW) 4.5/5.0 5.6/6.3 7.1/8.0 Electrical Power supply 1 phase 50Hz 230V (220-240V) characteristics Running current (A) 0.34 0.37 0.62 Power consumption (kW) 0.042 0.046 0.075 Starting current (A) 0.51 0.54 0.80 Appearance Main unit Heat-insulating material attached Zinc hot dipping steel plate Ceiling panel RBC-US21PGE Panel color Moon white (Munsel 2.5GY9.0/0.5) Dimension Main unit Height (mm) 200 Total weight Width Depth Ceiling panel Height Width Depth Main unit Ceiling panel (mm) (mm) (mm) (mm) (mm) (kg) (kg) 1000 710 20 1230 800 21 22 5.5 Finned tube Polyethylene foam + Expanded polystyrene Centrifugal fan (Sirocco fan) 3 (m /h) 750 780 1140 (m3/h) 690/630 720/660 960/810 Motor (W) 30 Air filter Standard filter attached (Long life filter) Controller Remote controller Connecting pipe Gas pipe (mm) 12.7 15.9 Liquid pipe (mm) 6.4 9.5 Drain pipe (Nominal dia.mm) 25 (Polyvinyl chloride tube : External dia.32 Internal dia.25) Sound pressure level High/Mid./Low (dB(A)) 37/35/32 38/36/34 45/41/37 Heat exchanger Soundproof / Heat-insulating material Fan High Standard air flow (Mid./Low) A-15 1 1. Specification 1-way (2 series) Air Discharge Cassette Type 60Hz Model name MMUAP0152SH AP0182SH AP0242SH Cooling/Heating capacity (kW) 4.5/5.0 5.6/6.3 7.1/8.0 Electrical Power supply 1 phase 60Hz 220V characteristics Running current (A) 0.35 0.39 0.62 Power consumption (kW) 0.041 0.045 0.073 Starting current (A) 0.53 0.54 0.80 Appearance Main unit Heat-insulating material attached Zinc hot dipping steel plate Ceiling panel RBC-US21PGE Panel color Moon white (Munsel 2.5GY9.0/0.5) Dimension Main unit Height (mm) 200 Total weight Width Depth Ceiling panel Height Width Depth Main unit Ceiling panel (mm) (mm) (mm) (mm) (mm) (kg) (kg) 1000 710 20 1230 800 21 22 5.5 Finned tube Polyethylene foam + Expanded polystyrene Centrifugal fan (Sirocco fan) 3 (m /h) 750 780 1140 (m3/h) 690/630 720/660 960/810 Motor (W) 30 Air filter Standard filter attached (Long life filter) Controller Remote controller Connecting pipe Gas pipe (mm) 12.7 15.9 Liquid pipe (mm) 6.4 9.5 Drain pipe (Nominal dia.mm) 25 (Polyvinyl chloride tube : External dia.32 Internal dia.25) Sound pressure level High/Mid./Low (dB(A)) 37/35/32 38/36/34 45/41/37 Heat exchanger Soundproof / Heat-insulating material Fan High Standard air flow (Mid./Low) 2 A-16 2. Dimensions 1-way (2 series) Air Discharge Cassette Type (MMU-AP***SH) 56 Cable inlet (Knockout hole) 252 248 Drain pipe connecting port (Be sure to connect the attached flexible hose.) 112 72 Fresh air inlet (Ø92 knockout hole) 20 C/L 1060 Hanging bolt pitch 1190 Ceiling opening size 1230 Panel external size 20 1000 Unit external size 706 20 216 800 Panel external size 20 135 220 760 Ceiling opening size 475 Hanging bolt pitch 233 122 710 Unit external size C/L 80 60 43 Cable inlet 100 Ø112 (4-tapping screw under-hole) 94 154 Refrigerant pipe connecting port Gas side B Refrigerant pipe connecting port Liquid side A 20 73.4 93 200 76 Hanging bolt M10 or W3/8 (Local supply) Lower surface of ceiling Ceiling panel (Sold separately) Model name MMU- A B AP015, AP018 type Ø6.4 Ø12.7 AP024 type Ø9.5 Ø15.9 120 2.7 Wired remote controller RBC-AMT21E 4 RBC-AMT31E Simple wired remote controller RBC-AS21E RBC-AS21E2 Wireless remote controller kit 16 TCB-AX21E 120 TCB-AX21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 For front air discharge unit (Sold separately) knockout hole A-17 3 3. Electrical current characteristics 1-way (2 series) Air Discharge Cassette Type 4 A-18 Type Model Nominal Voltage Voltage Range (V-Ph-Hz) Min Max 230-1-50 198 264 230-1-50 198 264 230-1-50 198 264 S-MMS (50Hz) MMU-AP0152SH MMU-AP0182SH MMU-AP0242SH S-MMS (60Hz) MMU-AP0152SH MMU-AP0182SH MMU-AP0242SH 220-1-60 220-1-60 220-1-60 198 198 198 S-HRM MMU-AP0152SH MMU-AP0182SH MMU-AP0242SH 230-1-50 230-1-50 230-1-50 198 198 198 Fan Motor kW FLA 0.030 0.40 0.030 0.42 0.030 0.71 Power Supply MCA MOCP 0.49 15 0.53 15 0.88 15 264 264 264 0.030 0.030 0.030 0.40 0.45 0.75 0.50 0.57 0.94 15 15 15 264 264 264 0.030 0.030 0.030 0.40 0.42 0.71 0.49 0.53 0.88 15 15 15 4. Sensible capacity table 1-way (2 series) Air Discharge Cassette Type (MMU-AP***SH) 14.0CWB 20CDB TC SHC 16.0CWB 23CDB TC SHC TC : Total capacity [kW] SHC : Sensible capacity [kW] Indoor air temp. 18.0CWB 19.0CWB 20.0CWB 22.0CWB 24.0CWB 26CDB 27CDB 28CDB 30CDB 32CDB TC SHC TC SHC TC SHC TC SHC TC SHC 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.6 3.5 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.7 2.7 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.0 3.8 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 2.9 2.8 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.2 4.1 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.1 3.0 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.4 4.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.1 3.0 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.5 4.4 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.1 3.0 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.7 4.6 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.1 3.0 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.0 4.8 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.0 2.9 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.5 4.3 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.3 3.3 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 4.9 4.8 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.6 3.5 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.3 5.1 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.8 3.7 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.4 5.3 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.8 3.7 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.6 5.4 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.8 3.7 6.1 6.1 6.1 6.1 6.1 6.1 6.1 6.1 6.1 6.1 6.1 6.1 6.1 6.1 5.9 5.7 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.7 3.6 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.2 6.0 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.7 3.6 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.6 5.5 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.3 4.2 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.2 6.1 4.7 4.7 4.7 4.7 4.7 4.7 4.7 4.7 4.7 4.7 4.7 4.7 4.7 4.7 4.6 4.4 6.9 6.9 6.9 6.9 6.9 6.9 6.9 6.9 6.9 6.9 6.9 6.9 6.9 6.9 6.7 6.5 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 4.9 4.7 7.1 7.1 7.1 7.1 7.1 7.1 7.1 7.1 7.1 7.1 7.1 7.1 7.1 7.1 6.9 6.7 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 4.8 4.7 7.3 7.3 7.3 7.3 7.3 7.3 7.3 7.3 7.3 7.3 7.3 7.3 7.3 7.3 7.1 6.9 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 4.8 4.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.5 7.3 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 4.8 4.7 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.1 7.8 7.6 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.7 4.6 Unit Outdoor size air temp. CDB 015 018 024 A-19 5 5. Wiring diagrams on side 1-way (2 series) Air Discharge Cassette Type (MMU-AP***SH) 6 A-20 6. Air speed characteristics 1-way (2 series) Air Discharge Cassette Type Heating mode MMU-AP0152SH, AP0182SH 3.5m Main unit 3m 2m 1m 0.3 1.0 0.3 0.5 0.5 1m 2m 3m 4m MMU-AP0242SH 3.5m Main unit 3m 2m 0.3 1.0 1m 0.3 0.5 0.5 1m 2m 3m 4m A-21 7 7. Sound Characteristics (NC Curve) 1-way (2 series) Air Discharge Cassette Type MMU-AP0242SH MMU-AP0152SH Fan tap Sound pressure level (dB(A)) H M L 37 35 32 Fan tap Sound pressure level (dB(A)) M L 45 41 37 90 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 H 30 M NC-30 L 20 Approximate threshold of hearing for continuous noise NC-20 10 Octave band sound pressure level (dB) Octave band sound pressure level (dB) 90 H 80 70 NC-70 60 NC-60 50 NC-50 40 H M NC-40 30 L NC-30 20 Approximate threshold of hearing for continuous noise NC-20 10 63 125 250 500 1000 2000 4000 8000 Octave band center frequency (Hz) 63 125 250 500 1000 2000 4000 8000 Octave band center frequency (Hz) MMU-AP0182SH Fan tap Sound pressure level (dB(A)) H M L 38 36 34 Octave band sound pressure level (dB) 90 80 70 NC-70 60 NC-60 50 NC-50 40 H M 30 L 20 Approximate threshold of hearing for continuous noise 10 63 125 250 NC-40 NC-30 NC-20 500 1000 2000 4000 8000 Octave band center frequency (Hz) 8 A-22 Center 1.5m Microphone 8. Fresh air intake (Design guide) 1-way (2 series) Air Discharge Cassette Type Caution The fresh air shall be conditioned by a heat reclaim ventilator or similar. Ensure the fresh air volume is determined so that mixed suction air and fresh air can maintain the operating temperature. *1.Recommended conditioned air temperature is 12 °C to 30 °C. However, Make a fresh air volume within 20% of standard. Model name Standard air flow MMU(m3/h) AP0152SH 750 AP0182SH 780 AP0242SH 1140 Install a filter within the fresh air duct. (Fresh air does not pass through the filter of Indoor unit.) Insulate the fresh air duct. Electrically connect the fan of the Heat exchanger unit and the Indoor unit to a single isolator. 80 70 Static Pressure (Pa) MMU-AP0152SH,MMU-AP182SH 60 50 40 30 MMU-AP0242SH 20 10 0 0 50 100 150 200 250 Fresh Air Volume (m3/h) Indoor unit Duct fan motor Fresh Air Volume Flange Option :TCB-FF101URE Inter - lock circuit Connect the driving relay of the duct fan(DC 12V) between 1 and 6 on the indoor P.C. board. (Rated current of the relay for duct fan should be up to 75mA.) After installation, carry out a trial operation to check that the duct fan of the indoor unit start/stop simultaneously. (Carry out the trial operation following the installation manual of the indoor unit.) A-23 9 9. Units center of gravity 1-way (2 series) Air Discharge Cassette Type Model name X (mm) Y (mm) Z (mm) 370 475 80 MMU-AP0152SH MMU-AP0182SH MMU-AP0242SH 10 A-24 Weight (kg) Main unit Ceiling panel 20 5.5 21 5.5 Oct. 05’ Engineering Data Slim Duct Type Indoor Unit MMD-AP0071SPH MMD-AP0091SPH MMD-AP0121SPH MMD-AP0151SPH MMD-AP0181SPH MMD-AP0071SPH (SH)-C MMD-AP0091SPH (SH)-C MMD-AP0121SPH (SH)-C MMD-AP0151SPH (SH)-C MMD-AP0181SPH (SH)-C MMD-AP0071SPH-K MMD-AP0091SPH-K MMD-AP0121SPH-K MMD-AP0151SPH-K MMD-AP0181SPH-K Contents 1. 2. 3. 4. 5. 6. 7. 8. Specifications Electrical current characteristics Dimensions Sensible capacity table Wiring diagrams Fan characteristics Sound characteristics (NC Curve) Fresh air intake (Design guide) A-25 A-26 1. Specification 50Hz Model name MMD- AP0071SPH AP0091SPH AP0121SPH AP0151SPH Cooling/Heating capacity (kW) 2.2/2.5 2.8/3.2 3.6/4.0 4.5/5.0 Electrical 1 phase 50Hz 230V (220-240V) Power supply characteristics Running current (A) 0.29 0.29 0.31 0.32 Power consumption (kW) 0.039 0.039 0.043 0.045 Starting current (A) 0.51 0.51 0.54 0.56 Appearance Zinc hot dipping steel plate Dimension Height (mm) 210 Width (mm) 845 Depth (mm) 645 Total weight (kg) 22 22 22 23 Heat exchanger Soundproof / Heat-insulating material Fan High Standard air (Mid./Low) flow Motor External static pressure (m3/h) (m3/h) (W) (Pa) Air filter pressure loss (Pa) Controller Air filter Connecting pipe Gas pipe (mm) Liquid pipe (mm) Drain pipe (Nominal dia.mm) (dB(A)) Sound pressure level Under air inlet (dB(A)) High/Mid./Low Back air inlet Sound power level (dB(A)) AP0181SPH 5.6/6.3 0.39 0.054 0.68 23 Finned tube Polyethylene foam + Polyurethane foam Centrifugal fan (Sirocco fan) 540 600 690 780 470/400 520/450 600/520 680/580 60 6 (Factory setting) 5 (Factory setting) 4 (Factory setting) -16-31-46 4steps -15-30-45 4steps -14-29-44 4steps 4 5 6 Remote controller Standard filter supplied (Long life filter) 9.5 12.7 6.4 25 (Polyvinyl chloride tube : External dia.32 Internal dia.25) 36/33/30 38/35/32 39/36/33 40/38/36 28/26/24 29/27/25 32/30/28 33/3129 51 53 54 55 * This sound pressure level is measured on the condition of Factory setting external static pressure. * This sound pressure level are measured in an anechoic chamber in accordance with JIS B8616. A-27 1 1. Specification 60Hz Model name MMD- AP0071SPH AP0091SPH AP0121SPH AP0151SPH Cooling/Heating capacity (kW) 2.2/2.5 2.8/3.2 3.6/4.0 4.5/5.0 Electrical Power supply 1 phase 60Hz 220V characteristics Running current (A) 0.27 0.27 0.30 0.31 Power consumption (kW) 0.037 0.037 0.041 0.043 Starting current (A) 0.47 0.47 0.53 0.54 Appearance Zinc hot dipping steel plate Dimension Height (mm) 210 Width (mm) 845 Depth (mm) 645 Total weight (kg) 22 22 22 23 Heat exchanger Soundproof / Heat-insulating material Fan High Standard air (Mid./Low) flow Motor External static pressure (m3/h) (m3/h) (W) (Pa) Air filter pressure loss (Pa) Controller Air filter Connecting pipe Gas pipe (mm) Liquid pipe (mm) Drain pipe (Nominal dia.mm) Sound pressure level Under air inlet (dB(A)) High/Mid./Low Back air inlet (dB(A)) Sound power level (dB(A)) AP0181SPH 5.6/6.3 0.37 0.052 0.65 23 Finned tube Polyethylene foam + Polyurethane foam Centrifugal fan (Sirocco fan) 540 600 690 780 470/400 520/450 600/520 680/580 60 6 (Factory setting) 5 (Factory setting) 4 (Factory setting) -16-31-46 4steps -15-30-45 4steps -14-29-44 4steps 4 5 6 Remote controller Standard filter supplied (Long life filter) 9.5 12.7 6.4 25 (Polyvinyl chloride tube : External dia.32 Internal dia.25) 36/33/30 38/35/32 39/36/33 40/38/36 28/26/24 29/27/25 32/30/28 33/31/29 51 53 54 55 * This sound pressure level is measured on the condition of Factory setting external static pressure. * This sound pressure level are measured in an anechoic chamber in accordance with JIS B8616. 2 A-28 1. Specification China Model Model name MMD- AP0071SPH-C AP0091SPH-C AP0121SPH-C AP0151SPH-C AP0181SPH-C Cooling/Heating capacity (kW) 2.2/2.5 2.8/3.2 3.6/4.0 4.5/5.0 5.6/6.3 Electrical Power supply 1 phase 50Hz 220V characteristics Running current (A) 0.29 0.29 0.31 0.32 0.39 Power consumption (kW) 0.039 0.039 0.043 0.045 0.054 Starting current (A) 0.51 0.51 0.54 0.56 0.68 Appearance Zinc hot dipping steel plate Dimension Height (mm) 210 Width (mm) 845 Depth (mm) 645 Total weight (kg) 22 22 22 23 23 Heat exchanger Finned tube Soundproof / Heat-insulating material Polyethylene foam + Polyurethane foam Fan Centrifugal fan (Sirocco fan) 3 High (m /h) Standard air 540 600 690 780 (Mid./Low) (m3/h) flow 470/400 520/450 600/520 680/580 Motor External static pressure Controller Air filter Connecting Gas pipe pipe Liquid pipe (W) (Pa) (mm) (mm) Drain pipe (Nominal dia.mm) Sound pressure level Under air inlet (dB(A)) High/Mid./Low Back air inlet (dB(A)) 60 10(factory setting)-20-35-50 4steps Remote controller Field supply 9.5 12.7 6.4 25 (Polyvinyl chloride tube : External dia.32 Internal dia.25) 36/33/30 38/35/32 39/36/33 40/38/36 28/26/24 29/27/25 32/30/28 33/31/29 * This sound pressure level is measured on the condition of Factory setting external static pressure. * This sound pressure level are measured in an anechoic chamber in accordance with JIS B8616. A-29 3 1. Specification China Model Model name MMD- AP0071SH-C P0091SH-C AP0121SH-C AP0151SH-C Cooling/Heating capacity (kW) 2.2/2.5 2.8/3.2 3.6/4.0 4.5/5.0 Electrical 1 phase 50Hz 220V Power supply characteristics Running current (A) 0.26 0.26 0.27 0.28 Power consumption (kW) 0.027 0.027 0.031 0.033 Starting current (A) 0.46 0.46 0.47 0.49 Appearance Zinc hot dipping steel plate Dimension Height (mm) 210 Width (mm) 845 Depth (mm) 645 Total weight (kg) 22 22 22 23 Heat exchanger Soundproof / Heat-insulating material Fan High Standard air (Mid./Low) flow Motor External static pressure Controller Air filter Connecting Gas pipe pipe Liquid pipe (m3/h) (m3/h) (W) (Pa) (mm) (mm) Drain pipe (Nominal dia.mm) Sound pressure level Under air inlet (dB(A)) High/Mid./Low Back air inlet (dB(A)) 4 A-30 AP0181SH-C 5.6/6.3 0.35 0.042 0.61 23 Finned tube Polyethylene foam + Polyurethane foam Centrifugal fan (Sirocco fan) 540 600 690 780 470/400 520/450 600/520 680/580 60 10(factory setting)-20-35-50 4steps Remote controller Field supply 9.5 12.7 6.4 20 (Polyvinyl chloride tube : External dia.26 Internal dia.20) 36/33/30 38/35/32 39/36/33 40/38/36 28/26/24 29/27/25 32/30/28 33/31/29 1. Specification 60Hz Model name MMD- AP0071SPH-K AP0091SPH-K AP0121SPH-K AP0151SPH-K Cooling/Heating capacity (kW) 2.2/2.5 2.8/3.2 3.6/4.0 4.5/5.0 Electrical 1 phase 60Hz 220V Power supply characteristics Running current (A) 0.27 0.27 0.30 0.31 Power consumption (kW) 0.037 0.037 0.041 0.043 Starting current (A) 0.47 0.47 0.53 0.54 Appearance Zinc hot dipping steel plate Dimension Height (mm) 210 Width (mm) 845 Depth (mm) 645 Total weight (kg) 22 22 22 23 Heat exchanger Soundproof / Heat-insulating material Fan High Standard air (Mid./Low) flow Motor External static pressure (m3/h) (m3/h) (W) (Pa) Air filter pressure loss (Pa) Controller Air filter Connecting pipe Gas pipe (mm) Liquid pipe (mm) Drain pipe (Nominal dia.mm) (dB(A)) Sound pressure level Under air inlet (dB(A)) High/Mid./Low Back air inlet AP0181SPH-K 5.6/6.3 0.37 0.052 0.65 23 Finned tube Polyethylene foam + Polyurethane foam Centrifugal fan (Sirocco fan) 540 600 690 780 470/400 520/450 600/520 680/580 60 6 (Factory setting) 5 (Factory setting) 4 (Factory setting) -16-31-46 4steps -15-30-45 4steps -14-29-44 4steps 4 5 6 Remote controller Standard filter supplied (Long life filter) 9.5 12.7 6.4 25 (Polyvinyl chloride tube : External dia.32 Internal dia.25) 36/33/30 38/35/32 39/36/33 40/38/36 28/26/24 29/27/25 32/30/28 33/31/29 * This sound pressure level is measured on the condition of Factory setting external static pressure. * This sound pressure level are measured in an anechoic chamber in accordance with JIS B8616. A-31 5 2. Electrical current characteristics Type 6 A-32 Model Nominal Voltage Voltage Range (V-Ph-Hz) Min Max 230-1-50 198 264 230-1-50 198 264 230-1-50 198 264 230-1-50 198 264 230-1-50 198 264 Fan Motor kW FLA 0.060 0.35 0.060 0.35 0.060 0.37 0.060 0.38 0.060 0.47 Power Supply MCA MOCP 0.44 15 0.44 15 0.47 15 0.48 15 0.59 15 S-MMS (50Hz) MMD-AP0071SPH MMD-AP0091SPH MMD-AP0121SPH MMD-AP0151SPH MMD-AP0181SPH S-MMS (60Hz) MMD-AP0071SPH MMD-AP0091SPH MMD-AP0121SPH MMD-AP0151SPH MMD-AP0181SPH 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 198 198 198 198 198 264 264 264 264 264 0.060 0.060 0.060 0.060 0.060 0.32 0.32 0.36 0.37 0.44 0.41 0.41 0.45 0.47 0.56 15 15 15 15 15 S-HRM MMD-AP0071SPH MMD-AP0091SPH MMD-AP0121SPH MMD-AP0151SPH MMD-AP0181SPH 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 198 198 198 198 198 264 264 264 264 264 0.060 0.060 0.060 0.060 0.060 0.35 0.35 0.37 0.38 0.47 0.44 0.44 0.47 0.48 0.59 15 15 15 15 15 3. Dimensions MMD-AP0071SPH(-K), AP0091SPH(-K), AP0121SPH(-K), AP0151SPH(-K), AP0181SPH(-K) 210 21 21 803 (inside) 103 Air filter Refrigerant piping 511 645 19 4-Ø4 67 20 21 168 (inside) 57 21 845 359 372 422 502 168 40 67 120 80 Ø9 2 31 805 80 59 33 163 910 Fresh air inlet (Knock-out hole) Drain-up port Hanger plate Air inlet connecting flange (Field supply) 100 266.5 100 805 12.5 286.8 41.5 8.2 or less Underside 100 100 100 100 100 100 100 100 100 100 45.3 12.5 100 825 n=24 M5 (Ø4.2 mounting hole) 805 12.5 12.5 100 100 100 100 100 188.6 44.3 100 170 44.3 Rearside Wired remote controller RBC-AMT21E RBC-AMT31E Simple wired remote controller RBC-AS21E RBC-AS21E2 Wireless remote controller kit TCB-AX21E TCB-AX21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 825 n=22 M5 (Ø4.2 mounting hole) A-33 7 3. Dimensions Installation space (length:mm) 5 or more 210 Air outlet 100 or more Under air inlet 250 or more Rear air inlet 5 or more 5 or more 210 210 235 or m Air inlet Ceiling 235 or more Air intlet 235 or more Ceiling 300 or more 50 or more 2500 or more 2500 or more Floor surface Floor surface Service space (length:mm) Air outlet 50 50 645 945 Air filter Service door (Ceiling opening) 645 645 945 Service door (Ceiling opening) Air filter 745 745 945 8 A-34 3. Dimensions 21 MMD-AP007SPH-C, AP0091SPH-C, AP0121SPH-C, AP0151SPH-C, AP0181SPH-C, MMD-AP0071SH-C, AP0091SH-C, AP0121SH-C, AP0151SH-C, AP0181SH-C 210 803 (inside) 21 21 Natural drain port 103 Refrigerant piping 80 511 645 19 359 372 422 502 805 910 59 40 168 67 80 146 31 120 Ø9 2 4-Ø4 67 20 21 168 (inside) 57 845 33 163 Fresh air inlet (Knock-out hole) Drain-up port (SPH model only) Hanger plate Air inlet connecting flange (Field supply) 100 266.5 100 805 12.5 286.8 41.5 8.2 or less Underside 100 100 100 100 100 100 100 100 100 100 45.3 12.5 100 825 n=24 M5 (Ø4.2 mounting hole) Rearside 12.5 12.5 100 100 100 100 100 188.6 44.3 100 170 44.3 805 Wired remote controller RBC-AMT21E RBC-AMT31E Simple wired remote controller RBC-AS21E RBC-AS21E2 Wireless remote controller kit TCB-AX21E TCB-AX21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2 825 n=22 M5 (Ø4.2 mounting hole) A-35 9 3. Dimensions Installation space (length:mm) MMD-AP0071SPH-C, MMD-AP0091SPH-C, MMD-AP0121SPH-C, MMD-AP0151SPH-C, MMD-AP0181SPH-C 5 or more 235 or more 210 Air outlet 100 or more 250 or more MMD-AP0071SH-C, MMD-AP0091SH-C, MMD-AP0121SH-C, MMD-AP0151SH-C, MMD-AP0181SH-C Drain piping left side Drain piping 5 or more Air outlet 210 100 or more 235 or more 250 or more Drain pipng right side Drain piping 5 or more Air outlet 210 250 or more 235 or more 200 or more (Refrigerant piping space) MMD-AP0071SPH-C, MMD-AP0091SPH-C, MMD-AP0121SPH-C, MMD-AP0151SPH-C, MMD-AP0181SPH-C MMD-AP0071SH-C, MMD-AP0091SH-C, MMD-AP0121SH-C, MMD-AP0151SH-C, MMD-AP0181SH-C Under air inlet 5 or more 210 235 or more Air inlet Ceiling 50 or more 2500 or more Floor surface Rear air inlet 5 or more Air intlet Ceiling 300 or more 2500 or more Floor surface 10 A-36 210 235 or more 3. Dimensions Service space (length:mm) MMD-AP0071SPH-C, MMD-AP0091SPH-C, MMD-AP0121SPH-C, MMD-AP0151SPH-C, MMD-AP0181SPH-C Air outlet 50 50 945 645 Service door (Ceiling opening) 645 945 MMD-AP0071SH-C, MMD-AP0091SH-C, MMD-AP0121SH-C, MMD-AP0151SH-C, MMD-AP0181SH-C Drain piping left side Drain piping Air outlet 50 100 645 995 Service door (Ceiling opening) 645 995 Drain pipng right side Drain piping Air outlet 100 50 995 645 Service door (Ceiling opening) 645 995 A-37 11 4. Sensible capacity table Slim Duct Type ( MMD-AP***SPH ) 14.0CWB 20CDB TC SHC 16.0CWB 23CDB TC SHC TC : Total capacity [kW] Indoor air temp. 18.0CWB 19.0CWB 20.0CWB 26CDB 27CDB 28CDB TC SHC TC SHC TC SHC 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.7 1.7 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.5 1.5 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 1.9 1.9 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.6 1.6 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.0 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.7 1.7 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.1 2.1 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.7 1.7 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.2 2.1 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.2 2.2 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.8 1.8 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.4 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 1.9 1.9 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.6 2.6 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.0 2.0 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.7 2.6 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.0 2.0 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 2.9 2.8 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.1 2.1 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.2 3.1 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.3 2.2 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.4 3.3 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.4 2.4 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.5 3.4 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.4 2.4 Unit Outdoor size air temp. CDB 007 009 012 12 A-38 SHC : Sensible capacity [kW] 22.0CWB 30CDB TC SHC 24.0CWB 32CDB TC SHC 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.7 1.7 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.3 2.3 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.7 1.7 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.4 2.4 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.6 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.8 2.7 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.0 2.0 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.0 2.9 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.0 2.0 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.1 3.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 1.9 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.6 3.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.4 2.4 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.8 3.7 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.4 2.3 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.0 3.9 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.3 2.3 4. Sensible capacity table Slim Duct Type ( MMD-AP***SPH ) 14.0CWB 20CDB TC SHC 16.0CWB 23CDB TC SHC TC : Total capacity [kW] Indoor air temp. 18.0CWB 19.0CWB 20.0CWB 26CDB 27CDB 28CDB TC SHC TC SHC TC SHC 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.6 3.5 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.7 2.7 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.0 3.8 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 2.9 2.8 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.2 4.1 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.1 3.0 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.4 4.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.1 3.0 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.5 4.4 10.0 12.0 14.0 16.0 18.0 20.0 21.0 23.0 25.0 27.0 29.0 31.0 33.0 35.0 37.0 39.0 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.5 4.3 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.3 3.3 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 4.9 4.8 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.6 3.5 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.3 5.1 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.8 3.7 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.4 5.3 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.8 3.7 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.6 5.4 Unit Outdoor size air temp. CDB 015 018 SHC : Sensible capacity [kW] 22.0CWB 30CDB TC SHC 24.0CWB 32CDB TC SHC 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.1 3.0 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.7 4.6 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.1 3.0 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.0 4.8 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.0 2.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.8 3.7 6.1 6.1 6.1 6.1 6.1 6.1 6.1 6.1 6.1 6.1 6.1 6.1 6.1 6.1 5.9 5.7 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.7 3.6 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.2 6.0 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.7 3.6 A-39 13 5. Wiring diagrams MMD-AP0071SPH(SH), AP0091SPH(SH), AP0121SPH(SH), AP0151SPH(SH), AP0181SPH(SH) 14 A-40 6. Fan characteristics MMD-AP0071SPH MMD-AP0091SPH MMD-AP0121SPH Standard air volume : 540m3/h Standard air volume : 600m3/h 60 60 High (50Pa) 50 Upper limit of external static pressure(35Pa) High (35Pa) 40 Lower limit of external static pressure (50Pa) Low (50Pa) Upper limit of external static pressure(20Pa) 30 High (20Pa) Upper limit of external static pressure(10Pa) 20 Low (35Pa) External static pressure (Pa) 50 External static pressure (Pa) High (50Pa) Upper limit of external static pressure(50Pa) Upper limit of external static pressure(50Pa) High (35Pa) 40 Low (50Pa) Upper limit of external static pressure(20Pa) 20 Low (20Pa) 10 Upper limit of external static pressure(10Pa) Lower limit of external static pressure (20Pa) Low (10Pa) 400 500 600 Lower limit of external static pressure (35Pa) High (10Pa) High (10Pa) Low (20Pa) 0 300 High (20Pa) Low (35Pa) Lower limit of external static pressure (35Pa) 10 Lower limit of external static pressure (50Pa) Upper limit of external static pressure(35Pa) 30 700 0 300 Lower limit of external static pressure (20Pa) Low (10Pa) 400 500 600 700 Air Volume (m3/h) Air Volume (m3/h) MMD-AP0151SPH MMD-AP0181SPH Standard air volume : 690m3/h Standard air volume : 780m3/h 60 60 High (50Pa) High (50Pa) Upper limit of external static pressure(50Pa) 50 Upper limit of external static pressure(35Pa) 40 Lower limit of external static pressure (50Pa) Low (50Pa) 30 High (20Pa) 20 10 Low (35Pa) Upper limit of external static pressure(20Pa) Upper limit of external static pressure(10Pa) 0 400 500 Upper limit of external static pressure(50Pa) High (35Pa) Lower limit of external static pressure (35Pa) External static pressure (Pa) External static pressure (Pa) 50 High (35Pa) 40 Low (50Pa) 30 20 10 Low (20Pa) Lower limit of external static pressure (20Pa) 600 Air Volume (m3/h) 700 800 High (20Pa) Low (35Pa) High (10Pa) Low (10Pa) Lower limit of external static pressure (50Pa) Upper limit of external static pressure(35Pa) Upper limit of external static pressure(20Pa) Lower limit of external static pressure (35Pa) Upper limit of external static pressure(10Pa) Low (20Pa) Low (10Pa) 0 400 500 High (10Pa) 600 700 800 Lower limit of external static pressure (20Pa) 900 Air Volume (m3/h) A-41 15 6. Fan characteristics (Filter attached) MMD-AP0071SPH MMD-AP0091SPH MMD-AP0121SPH Standard air volume : 540m3/h Standard air volume : 600m3/h 60 60 High (50Pa) High (50Pa) Upper limit of external static pressure(50Pa) 50 50 Lower limit of external static pressure (50Pa) Upper limit of external static pressure(50Pa) Lower limit of externa static pressure (50Pa) Upper limit of external static pressure(35Pa) 30 Low (50Pa) Lower limit of external static pressure (35Pa) Low (35Pa) 20 High (20Pa) Upper limit of external static pressure(20Pa) External static pressure (Pa) External static pressure (Pa) Low (50Pa) 40 40 Upper limit o external static pressure(35Pa) 30 Low (35Pa) 20 Upper limit o external static pressure(20Pa) High (20Pa) Lower limit of external static pressure (20Pa) Lower limit of extern static pressure (20Pa) Low (20Pa) Low (20Pa) 10 10 Upper limit of external static pressure(10Pa) High (10Pa) Upper limit o external static pressure(10Pa) High (10Pa) Standard filter pressure loss Low (10Pa) 0 300 Lower limit of external static pressure (35Pa) High (35Pa) 400 500 600 Standard filter pressure loss Low (10Pa) 0 300 700 400 Air Volume (m3/h) 500 600 700 Air Volume (m3/h) MMD-AP0151SPH MMD-AP0181SPH Standard air volume : 690m3/h Standard air volume : 780m3/h 60 60 High (50Pa) High (50Pa) Upper limit of external static pressure(50Pa) Upper limit of external static pressure(50Pa) 50 50 Lower limit of external static pressure (50Pa) Upper limit of external static pressure(35Pa) Lower limit of external static pressure (50Pa) Upper limit of external static pressure(35Pa) Lower limit of external static pressure (35Pa) Low (50Pa) 30 Upper limit of external static pressure(20Pa) High (20Pa) Low (35Pa) 20 High (10Pa) 10 Upper limit of external static pressure(10Pa) External static pressure (Pa) External static pressure (Pa) High (35Pa) 40 40 Low (50Pa) Low (35Pa) 20 Upper limit of external static pressure(20Pa) Lower limit of externa static pressure (20Pa) Low (20Pa) Lower limit of external static pressure (35Pa) High (35Pa) 30 10 High (20Pa) Lower limit of external static pressure (20Pa) Upper limit of external static pressure(10Pa) High (10Pa) Low (20Pa) Low (10Pa) 0 400 Standard filter pressure loss 500 600 Air Volume (m3/h) 16 A-42 700 800 0 400 Standard filter pressure loss Low (10Pa) 500 600 700 Air Volume (m3/h) 800 900 6. Fan characteristics CHINA model (Filter attached) MMD-AP0071SPH-C, SH-C MMD-AP0091SPH-C, SH-C MMD-AP0121SPH-C, SH-C Standard air volume : 540m3/h Standard air volume : 600m3/h 60 60 High (50Pa) Upper limit of external static pressure(50Pa) High (50Pa) 50 50 Upper limit of external static pressure(50Pa) High (35Pa) 40 High (35Pa) Lower limit of external static pressure (50Pa) Low (50Pa) Upper limit of external static pressure(35Pa) 30 High (20Pa) 20 Upper limit of external static pressure(20Pa) Low (35Pa) External static pressure (Pa) External static pressure (Pa) Upper limit of external static pressure(35Pa) 40 Low (50Pa) 30 Upper limit of external static pressure(35Pa) 20 Upper limit of external static pressure(20Pa) Lower limit of external static pressure (50Pa) High (20Pa) Low (35Pa) Lower limit of external static pressure (35Pa) Lower limit of external static pressure (35Pa) Low (20Pa) High (10Pa) 10 10 High (10Pa) Low (20Pa) Upper limit of external static pressure(10Pa) 0 300 Lower limit of external static pressure (20Pa) Low (10Pa) 400 500 600 Lower limit of external static pressure (20Pa) Upper limit of external static pressure(10Pa) 0 300 700 Low (10Pa) 400 500 600 MMD-AP0151SPH-C, SH-C MMD-AP0181SPH-C, SH-C Standard air volume : 780m3/h Standard air volume : 690m3/h 60 60 High (50Pa) Upper limit of external static pressure(50Pa) High (50Pa) Upper limit of external static pressure(50Pa) 50 50 Upper limit of external static pressure(35Pa) Upper limit of external static pressure(35Pa) 40 Low (50Pa) Lower limit of external static pressure (50Pa) 30 High (20Pa) 20 Lower limit of extern static pressure (35Pa) Low (35Pa) High (35Pa) 40 Low (50Pa) Lower limit of external static pressure (50Pa) 30 Low (35Pa) 20 Upper limit of external static pressure(20Pa) High (20Pa) Lower limit of extern static pressure (35Pa) High (10Pa) Upper limit of external static pressure(20Pa) 500 Low (20Pa) Lower limit of external static pressure (20Pa) 600 700 800 Lower limit of exte static pressure (20Pa) Upper limit of external static pressure(10Pa) Low (10Pa) Air Volume (m3/h) High (10Pa) 10 Low (20Pa) Upper limit of external static pressure(10Pa) 0 400 External static pressure (Pa) External static pressure (Pa) High (35Pa) 10 700 Air Volume (m3/h) Air Volume (m3/h) 0 400 500 Low (10Pa) 600 700 800 900 Air Volume (m3/h) A-43 17 7. Sound Characteristics (NC Curve) MMD-AP0071SPH/SH , MMD-AP0091SPH/SH Measuring location 2m 1m Duct Duct Air outlet Rear air intake Air inlet Center 1.5m Microphone External static pressure 10Pa H M L 28 26 24 Fan tap Sound pressure level (dB(A)) 70 70 60 60 50 NC-50 40 NC-40 30 NC-30 H M 20 Octave band sound pressure level (dB) Octave band sound pressure level (dB) Fan tap Sound pressure level (dB(A)) External static pressure 20Pa L 29 27 25 50 NC-50 40 NC-40 30 NC-30 H M NC-20 L NC-20 Approximate threshold of hearing for continuous noise Approximate threshold of hearing for continuous noise 10 10 63 125 250 500 1000 2000 4000 63 8000 125 External static pressure 35Pa Fan tap Sound pressure level (dB(A)) 500 1000 2000 4000 8000 External static pressure 50Pa H M L 30 28 26 Fan tap Sound pressure level (dB(A)) 70 60 60 50 NC-50 40 NC-40 30 NC-30 H M L Octave band sound pressure level (dB) 70 20 250 Octave band center frequency (Hz) Octave band center frequency (Hz) Octave band sound pressure level (dB) M 20 L H M L 32 29 27 50 NC-50 40 NC-40 H 30 NC-30 M L 20 NC-20 NC-20 Approximate threshold of hearing for continuous noise Approximate threshold of hearing for continuous noise 10 10 63 125 250 500 1000 2000 Octave band center frequency (Hz) 18 A-44 H 4000 8000 63 125 250 500 1000 2000 Octave band center frequency (Hz) 4000 8000 7. Sound Characteristics (NC Curve) MMD-AP0121SPH/SH Measuring location 2m 1m Duct Duct Air outlet Rear air intake Air inlet Center 1.5m Microphone External static pressure 10Pa H M L 29 27 25 Fan tap Sound pressure level (dB(A)) 70 70 60 60 50 NC-50 40 NC-40 30 H NC-30 M Octave band sound pressure level (dB) Octave band sound pressure level (dB) Fan tap Sound pressure level (dB(A)) External static pressure 20Pa L 20 H M L 30 28 26 50 NC-50 40 NC-40 H 30 NC-30 M L 20 NC-20 NC-20 Approximate threshold of hearing for continuous noise Approximate threshold of hearing for continuous noise 10 10 63 125 250 500 1000 2000 4000 8000 63 125 Octave band center frequency (Hz) External static pressure 35Pa M L 31 29 27 Fan tap Sound pressure level (dB(A)) 70 70 60 60 50 NC-50 40 NC-40 H 30 500 1000 2000 4000 8000 External static pressure 50Pa H NC-30 M Octave band sound pressure level (dB) Octave band sound pressure level (dB) Fan tap Sound pressure level (dB(A)) 250 Octave band center frequency (Hz) H M L 32 30 28 50 NC-50 40 NC-40 H 30 NC-30 M L L 20 20 NC-20 NC-20 Approximate threshold of hearing for continuous noise Approximate threshold of hearing for continuous noise 10 10 63 125 250 500 1000 2000 Octave band center frequency (Hz) 4000 8000 63 125 250 500 1000 2000 4000 8000 Octave band center frequency (Hz) A-45 19 7. Sound Characteristics (NC Curve) MMD-AP0151SPH/SH Measuring location 2m 1m Duct Duct Air outlet Rear air intake Air inlet Center 1.5m Microphone External static pressure 10Pa External static pressure 20Pa H M L 32 30 28 Fan tap Sound pressure level (dB(A)) 70 70 60 60 50 NC-50 40 NC-40 30 H NC-30 M Octave band sound pressure level (dB) Octave band sound pressure level (dB) Fan tap Sound pressure level (dB(A)) L 33 31 29 50 NC-50 40 NC-40 30 M L NC-20 Approximate threshold of hearing for continuous noise Approximate threshold of hearing for continuous noise 10 63 125 250 500 1000 2000 4000 10 8000 63 125 Octave band center frequency (Hz) 500 M L 34 32 30 Fan tap Sound pressure level (dB(A)) 70 60 60 50 NC-50 40 NC-40 H NC-30 M Octave band sound pressure level (dB) 70 M L 35 33 31 NC-50 40 NC-40 H 30 500 NC-30 M 20 NC-20 Approximate threshold of hearing for continuous noise 10 250 8000 50 Approximate threshold of hearing for continuous noise 125 4000 L NC-20 63 2000 H L 20 1000 External static pressure 50Pa H 30 250 Octave band center frequency (Hz) External static pressure 35Pa Fan tap Sound pressure level (dB(A)) NC-30 H 20 NC-20 Octave band sound pressur level (dB) M L 20 1000 2000 Octave band center frequency (Hz) 20 A-46 H 4000 8000 10 63 125 250 500 1000 2000 Octave band center frequency (Hz) 4000 8000 7. Sound Characteristics (NC Curve) MMD-AP0181SPH/SH Measuring location 2m 1m Duct Duct Air outlet Rear air intake Air inlet Center 1.5m Microphone External static pressure 10Pa H M L 33 31 29 Fan tap Sound pressure level (dB(A)) 70 70 60 60 50 NC-50 40 NC-40 H 30 NC-30 M Octave band sound pressure level (dB) Octave band sound pressure level (dB) Fan tap Sound pressure level (dB(A)) External static pressure 20Pa H M L 34 32 30 50 NC-50 40 NC-40 H 30 M L NC-30 L 20 20 NC-20 NC-20 Approximate threshold of hearing for continuous noise Approximate threshold of hearing for continuous noise 10 10 63 125 250 500 1000 2000 4000 8000 63 125 Octave band center frequency (Hz) External static pressure 35Pa 500 1000 2000 4000 8000 External static pressure 50Pa H M L 35 33 31 Fan tap Sound pressure level (dB(A)) 70 70 60 60 50 NC-50 40 NC-40 H 30 NC-30 M L 20 Octave band sound pressure level (dB) Octave band sound pressure level (dB) Fan tap Sound pressure level (dB(A)) 250 Octave band center frequency (Hz) H M L 36 34 32 50 NC-50 40 NC-40 H 30 NC-30 M L 20 NC-20 NC-20 Approximate threshold of hearing for continuous noise Approximate threshold of hearing for continuous noise 10 10 63 125 250 500 1000 2000 Octave band center fequency (Hz) 4000 8000 63 125 250 500 1000 2000 4000 8000 Octave band center frequency (Hz) A-47 21 7. Sound Characteristics (NC Curve) MMD-AP0071SPH/SH , MMD-AP0091SPH/SH 2m Duct Air outlet Measuring location Center 1.5m Under air intake Air inlet Microphone External static pressure 10Pa H M L 36 33 30 Fan tap Sound pressure level (dB(A)) 70 70 60 60 50 NC-50 40 NC-40 H M 30 NC-30 L Octave band sound pressure level (dB) Octave band sound pressure level (dB) Fan tap Sound pressure level (dB(A)) External static pressure 20Pa 20 H M L 37 34 31 50 NC-50 40 NC-40 H M 30 NC-30 L 20 NC-20 NC-20 Approximate threshold of hearing for continuous noise Approximate threshold of hearing for continuous noise 10 10 63 125 250 500 1000 2000 4000 8000 63 125 Octave band center frequency (Hz) External static pressure 35Pa M L 39 36 33 Fan tap Sound pressure level (dB(A)) 70 70 60 60 50 NC-50 40 NC-40 H M 30 500 1000 2000 NC-30 L 20 8000 H M L 41 38 35 50 NC-50 H M 40 NC-40 L 30 NC-30 20 NC-20 NC-20 Approximate threshold of hearing for continuous noise Approximate threshold of hearing for continuous noise 10 10 63 125 250 500 1000 2000 Octave band center frequency (Hz) 22 A-48 4000 External static pressure 50Pa H Octave band sound pressure level (dB) Octave band soune pressure level (dB) Fan tap Sound pressure level (dB(A)) 250 Octave band center frequency (Hz) 4000 8000 63 125 250 500 1000 2000 Octave band center frequency (Hz) 4000 8000 7. Sound Characteristics (NC Curve) 2m MMD-AP0121SPH/SH Measuring location Duct Air outlet Under air intake Center 1.5m Air inlet Microphone External static pressure 20Pa External static pressure 10Pa Fan tap Sound pressure level (dB(A)) H M L 38 35 32 Fan tap Sound pressure level (dB(A)) 70 L 39 36 33 60 50 NC-50 40 NC-40 H M 30 NC-30 L Octave band sound pressure level (dB) Octave band sound pressure level (dB) M 70 60 20 50 NC-50 40 M 30 NC-20 Approximate threshold of hearing for continuous noise 10 125 250 500 1000 2000 4000 10 8000 63 125 Octave band center frequency (Hz) M L 41 38 35 Fan tap Sound pressure level (dB(A)) 70 60 60 50 NC-50 H NC-40 M L NC-30 20 NC-20 Octave band sound pressure frequency (dB) 70 30 250 2000 4000 8000 H M L 43 40 37 NC-50 H 40 NC-40 M L 30 NC-30 20 NC-20 Approximate threshold of hearing for continuous noise 10 125 1000 50 Approximate threshold of hearing for continuous noise 63 500 External static pressure 50Pa H 40 250 Octave band center frequency (Hz) External static pressure 35Pa Fan tap Sound pressure level (dB(A)) NC-30 L 20 NC-20 63 NC-40 H Approximate threshold of hearing for continuous noise Octave band sound pressure level (dB) H 500 1000 2000 Octave band center frequency (Hz) 4000 8000 10 63 125 250 500 1000 2000 4000 8000 Octave band center frequency (Hz) A-49 23 7. Sound Characteristics (NC Curve) MMD-AP0151SPH/SH 2m Measuring location Duct Air outlet Under air intake Center 1.5m Air inlet Microphone External static pressure 10Pa H M L 39 36 33 Fan tap Sound pressure level (dB(A)) 70 70 60 60 50 NC-50 40 NC-40 H M 30 NC-30 L Octave band sound frequency level (dB) Octave band sound pressure level (dB) Fan tap Sound pressure level (dB(A)) External static pressure 20Pa 20 H M L 40 37 34 50 NC-50 40 NC-40 H M 30 NC-30 L 20 NC-20 NC-20 Approximate threshold of hearing for continuous noise Approximate threshold of hearing for continuous noise 10 10 63 125 250 500 1000 2000 4000 8000 63 125 External static pressure 35Pa M L 41 38 35 Fan tap Sound pressure level (dB(A)) 70 70 60 60 50 NC-50 H 40 NC-40 M L 30 500 1000 2000 NC-30 20 8000 H M L 43 40 37 50 NC-50 H 40 NC-40 M L 30 NC-30 20 NC-20 NC-20 Approximate threshold of hearing for continuous noise Approximate threshold of hearing for continuous noise 10 10 63 125 250 500 1000 2000 Octave band center frequency (Hz) 24 A-50 4000 External static pressure 50Pa H Octave band sound frequency level (dB) Octave band sound pressure level (dB) Fan tap Sound pressure level (dB(A)) 250 Octave band center frequency (Hz) Octave band center frequency (Hz) 4000 8000 63 125 250 500 1000 2000 Octave band center frequency (Hz) 4000 8000 7. Sound Characteristics (NC Curve) MMD-AP0181SPH/SH 2m Measuring location Duct Air outlet Under air intake Center 1.5m Air inlet Microphone External static pressure 10Pa H M L 40 38 36 Fan tap Sound pressure level (dB(A)) 70 70 60 60 50 NC-50 40 NC-40 H M 30 NC-30 L Octave band sound pressure level (dB) Octave band sound pressure level (dB) Fan tap Sound pressure level (dB(A)) External static pressure 20Pa H M L 42 40 37 50 NC-50 H 40 NC-40 M L 30 NC-30 20 20 NC-20 NC-20 Approximate threshold of hearing for continuous noise Approximate threshold of hearing for continuous noise 10 10 63 125 250 500 1000 2000 4000 63 8000 125 External static pressure 35Pa 500 1000 2000 4000 8000 External static pressure 50Pa H M L 43 41 38 Fan tap Sound pressure level (dB(A)) 70 70 60 60 50 NC-50 H 40 NC-40 M L 30 NC-30 20 Octave band sound pressure level (dB) Octave band sound pressure level (dB) Fan tap Sound pressure level (dB(A)) 250 Octave band center frequency (Hz) Octave band center frequency (Hz) H M L 44 42 39 50 NC-50 H 40 NC-40 M L 30 NC-30 20 NC-20 NC-20 Approximate threshold of hearing for continuous noise Approximate threshold of hearing for continuous noise 10 10 63 125 250 500 1000 2000 Octave band center frequency (Hz) 4000 8000 63 125 250 500 1000 2000 4000 8000 Octave band center frequency (Hz) A-51 25 8. Fresh air intake (Design guide) Slim Duct Type MMD-AP0071SPH, AP0091SPH, AP0121SPH MMD-AP0071SPH-C, AP0091SPH-C, AP0121SPH-C MMD-AP0071SH-C, AP0091SH-C, AP0121SH-C Caution The fresh air shall be conditioned by heat reclaim ventilator or similar. Ensure the fresh air volume is determined so that mixed suction air and fresh air maintain the operating temperature. *1.Recommended conditioned air temperature is 12 °C to 30 °C. However, Make a fresh air volume within 20% of standard. Model name MMD- Standard air flow (m3/h) AP0071SPH AP0071SPH-C AP0071SH-C 540 AP0091SPH AP0091SPH-C AP0091SH-C 540 AP0121SPH AP0121SPH-C AP0121SH-C 600 Install a air filter within the fresh air duct. ( Fresh air does not pass through the filter of Indoor unit.) Insulate the fresh air duct. Electrically connect the fan of the Heat exchanger unit and the Indoor unit to a single isolator. Static Pressure (Pa) 30 20 10 0 -10 0 20 40 60 80 100 120 140 Fresh Air Volume (m3/h) Indoor unit Duct fan motor Fresh Air Volume Flange Option :TCB-FF101URE Inter - lock circuit Connect the driving relay of the duct fan (DC 12V) between 1 and 6 on the indoor P.C. board. (Rated current of the relay for duct fan should be up to 75mA.) After installation, carry out a trial operation to check that the duct fan of the indoor unit start/stop simultaneously. (Carry out the trial operation following the installation manual of the indoor unit.) 26 A-52 8. Fresh air intake (Design guide) Slim Duct Type MMD-AP0151SPH, AP0181SPH MMD-AP0151SPH-C, AP0181SPH-C MMD-AP0151SH-C, AP0181SH-C Caution The fresh air shall be conditioned by heat reclaim ventilator or similar. Ensure the fresh air volume is determined so that mixed suction air and fresh air maintain the operating temperature. *1.Recommended conditioned air temperature is 12 °C to 30 °C. However, Make a fresh air volume within 20% of standard. Model name MMD- Standard air flow (m3/h) AP0151SPH AP0151SPH-C AP0151SH-C 690 AP0181SPH AP0181SPH-C AP0181SH-C 780 Install a air filter within the fresh air duct. ( Fresh air does not pass through the filter of Indoor unit.) Insulate the fresh air duct. Electrically connect the fan of the Heat exchanger unit and the Indoor unit to a single isolator. Static Pressure (Pa) 60 50 AP0151 40 30 20 AP0181 10 0 -10 0 20 40 60 80 100 120 140 160 180 Fresh Air Volume (m3/h) Indoor unit Duct fan motor Fresh Air Volume Flange Option :TCB-FF101URE Inter - lock circuit Connect the driving relay of the duct fan (DC 12V) between 1 and 6 on the indoor P.C. board. (Rated current of the relay for duct fan should be up to 75mA.) After installation, carry out a trial operation to check that the duct fan of the indoor unit start/stop simultaneously. (Carry out the trial operation following the installation manual of the indoor unit.) A-53 27