Download Premier 888/8168 Installation Manual - EZ
Transcript
Quick Reference Guide & System Records Premier 24 Issue 2 Premier 24 Quick Reference & Factory Defaults Factory Defaults 1. Factory Defaults Menu Option User Codes Default Setup Users User 00 (Engineer) User 01 (Master) Users 02 - 16 1234 5678 Not Defined Zones Types 1 2 3-8 Zones 9 - 24 Zone Text All Zones Not Defined Zone Chime All Zones Silent Zone Wiring 1 – 24 Double Pole/EOL Menu 01: Exit Settle Time 02: Double Knock Dly 03: Activity Delay 04: Abort Delay 05: Courtesy Time 06: Pulse Period 1 07: ATS Fault Delay 08: AC Off Delay 09: Batt Test Period 10: Batt Test Time 11: Soak Test Time 12: Service Interval 13: Test Call Every 14: Zone Response 15: Confirmation Dly 008 Seconds 007 Seconds 024 Hours 180 Seconds 030 Seconds 010 Seconds 000 Minutes 005 Minutes 024 Hours 010 Seconds 014 Days 000 Weeks 024 Hours 008 x 8mSec. 060 Minutes System Config 00: Bell on Arm Fail 01: Bell is an SCB 02: Manual BST/GMT 03: Leave Omits 04: Enforce Com Delay 05: NVM is Locked 06: Engineer Only 07: Omit Tampers NO 08: 40 Column Printer 09: View Act. Fault 10: View Zone Faults 11: No Code Tamp 12: Code Tamp Alarms 13: Zone Short = Active 14: R/R=Silence/RST 15: Test Call = CT3 16: Batt Test = Disarm 17: Bell = 2nd Alarm 18: SNDR = 2nd Alarm 19: Abort = User Reset 20: 8XE = Tampers 1-8 21: 1st Zone = Confirm 22: Access = Confirm 23: EN50131 Disabled 24: Panel Grade 3 25: Disable RF PA’s 26: Armed Mask = Alarm 27: RF PA = Silent 28: Periodic Test Calls 1: Advisory Volume 2: Chime Volume 3: No. of Re-Arms 4: Anti-code Resets 5: Quick Count 6: Modem Level No Bell SAB Auto Remove Override Unlocked User + Engineer YES ** 80 Hide Hide Enable Locks Tamper Reset Only Timed Timed 1st Alarm 1st Alarm Eng. Zones 9-16 2nd No Conf. Enabled 2* Enable Fault Audible Dynamic 5 3 03 03 4 0 1: ATS Path Fault 2: Power Failure 3: Aux Fuse Blown 4: Bell Tamper 5: Aux Tamper 6: Panel Lid Tamper Enabled Enabled Enabled Enabled Enabled Enabled 7: Battery Faults Enabled Entry/Exit 1 Guard Access Guard Not Used 2. Arming Options Arming Modes Options 1 Options 2 Options 3 Exit Delay Entry Delay 1 Entry Delay 2 2nd Entry Dly Bell Delay! Bell Duration Coms Delay Part Bell Dly 030 Seconds 045 Seconds 045 Seconds 000 Seconds 000 Minutes 015 Minutes 000 Seconds 000 Seconds Full Arm! Part Arm 1! Part Arm 2! Part Arm 3! Entry/Exit Instant Instant Instant 1: Auto Part Arm! 2: Part Arm Silent! 3: Remote Arm 4: Time Arm CT1 5: Alarm Eng Reset! 6: Confirmation Reset! 7: Tamper Eng Reset! 8: Anti-code Reset! 1: Arm With No ATS! 2: Arm With AC Fail! 3: Part Arm Coms! 4: Unarm Fire Coms 5: Unarm Tamper Coms! 6: Log Part Omits! 7: Confirm In Entry! 8: Conf. After Entry! 1: Faults Eng Reset! 2: No ATS Eng Reset! 3: AC Fail Eng Reset! 4: Anti-Masking When Armed 5: Remote FOB After Entry . Disabled Disabled Enabled Disabled Disabled Enabled Disabled ** Enabled Enabled ** Enabled Disabled Disabled Disabled ** Disabled Disabled Enabled Disabled ** Disabled ** Disabled Disabled System Options Disabled Monitor Hardware 2 Default System Timers 1. Zone Setup Timers Option 3. Global Options INS249 Premier 24 Quick Reference & Factory Defaults Menu Factory Defaults Option Default 3. Global Options - Continued Control Timers System Text 1-4 Reset Message Banner Message Part Armed Banner Printer Header Part Arm 1 Part Arm 2 Part Arm 3 Not Defined Call Engineer to Reset System Call ARC Centre to Reset System Call Alarm Co. For Service No Location Text Has Been Setup Not Defined * PART ARMED * Not Defined Evening Arm Bedtime Arm 1 Bedtime Arm 2 All Tones Enabled Anti-code Message Service Message Location Text Speaker Tones Menu Reset Digi Test Com? Set Call Waiting Program Digi Digi Options UDL Options 4. Keypad Setup Zone Mapping Options Volume Sounder Options All Keypad zones 1: PA Enabled 2: Fire Enable 3: Medical Enabled 4: Tamper Disabled 5: PA Audible 6: PA Delayed 7: Quick Arm Keys 8: Info.LED> Output Not Mapped Disabled Disabled Disabled Enabled Silent Instant Off Armed All Keypads All Tones 5 Enabled Radio/SMS Setup 5. Expander Setup Auxiliary Input Volume Sounder Options All Expanders All Expanders All Tones Not Used 5 Enabled Com Port Setup 6. Output Setup Panel Outputs Com Channels Keypads 1-4 Outputs Expanders 1-2 Outputs PGM Outputs 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 - 10 11 - 16 1 1 2 3 4-8 1 2 3 4 5-8 INS249 Fire PA Alarm Armed Zones Locked Out Fault Present Confirmed Alarm Abort Tamper AC Mains Fail ATS Remote Test Not Used Not Used LED Control Armed Detector Test As Panel Outputs Not Used LED Control LED Control Option 7. UDL/Digi Options N/A N/A Number ARC 1 ARC 2 Digi is Enabled Pulse Dialling Pulse After 3 Blind Dialling Reserved Dial All Numbers Call Back Number 1 Call Back Number 2 UDL Password DL Attended Auto Call-Back Call Defeat Off DL Arm Limited Download When Armed Disable On Line Keypad Rings Required UDL Dial Attempts Pad ARC 1 Pri. No. Pad ARC 1 Sec. No. Pad ARC 1 Prefix Pad ARC 2 Pri. No. Pad ARC 2 Sec. No. Pad ARC 2 Prefix SMS No1 SMS No2 Onboard Digi Com 1 Com 2 Default N/A N/A Not Defined Not Defined Not Defined Disabled Tone Always Tone Wait Dial Tone N/A Dial Any Not Defined Not Defined Not Defined Unattended Manual On At Anytime Fully Armed Enabled 005 003 Not Defined Not Defined Not Defined Not Defined Not Defined Not Defined 07860980480 07785499993 Com300 No Module Fitted No Module Fitted 8. User Codes Setup Users User 00 (Engineer) User 01 (Master) User 02 - 16 1234 5678 *** Not Defined *** * Global option 24 alters the Programming of the control panel as defined below. ** These options are enabled/disabled when Config. Option 24 is programmed as ‘Grade 2/3’. *** All users except the engineer are defaulted to lock out during entry. Armed Detector Test Not Used Zones Locked Out Not Used Not Used Control Timer 4 Not Used 3 Premier 24 Quick Reference & Factory Defaults Quick Reference Guide 2. Quick Reference Guide Log Off Engineer ! "# Press " to log out of the Engineer Programming menu Zone Setup $ "# # # # # # # # # "# # # # # "# Use ! - % to enter zone number, & to edit, ! - % or ' to select a zone type, " to accept ! $ ) * + , . ! ! ! ! ! ! ! Zone Attributes 1 $ ) * + ! ! ! Zone Attributes 2 # # # # (only applicable for keyswitch zone types) "# # # # # "# # # # # # $ ) * + ! ! Key Attributes 2 $ * + ! ! ! Wiring Type ! ! ! ! ! Entry/Exit 2 Guard Guard Access 24Hr Audible Trouble ( % ' ' ' ' ' PA Silent Fire 24Hr Gas Auxiliary Tamper Exit Terminator Key Switch PA Audible O = Omittable F = Force Omit 1 = Part 1 Omit 2 = Part 2 Omit , . ( 3 = Part 3 Omit 1 = Chime 1 2 = Chime 2 G = Guard/Entry 2 D = Double Knock S = Shunt Group T = Soak Test F = Activity , . ( R = Reset I = Inverted Q = Quick Resp. ! = Shock Press & to edit, $ - , to select an attribute, " to accept !) Zone Text Entry/Exit 1 Press & to edit, $ - ( to select an attribute, " to accept # # # # ! ! Not Used Press & to edit, $ - ( to select an attribute, " to accept (not applicable to keyswitch zone types) "# 4 Zone Types I = Instant Arming s = Shunt Key F = Full Disable D = Disarm Only , . ( S = Silent Arming I = Inverted Q = Quick Resp. L = Latching Press & to edit, ! - % to select characters (press the required key the appropriate number of times), " to accept , JKL5 ABC2 - MNO6 DEF3 . PQRS7 GHI4 ( TUV8 Press & to alter wiring type, " to accept ! Normally Closed , $ Normally Open ) Double EOL . iD * ( + Triple EOL # $ ) * + .,?!1@“- % ! ' WXYZ9 0_ Move Cursor 1K/1K/3K 4K7/6K8/12K 2K2/4K7/6K8 4K7/4K7 INS249 Premier 24 Quick Reference & Factory Defaults Arming Options ) ! $ ) Timers Arming Modes Options Options 1 Options 2 Options 3 * !# # # # # # $# # # # # # # # # # # # # # # # )# # # # # INS249 Quick Reference Guide Use ' or " to select a timer, ! - % to enter a value, " to accept * 2nd Entry Delay -!Coms Delay ! Exit Delay $!Entry Delay 1 + Bell Delay! .!Part Bell Delay ! )!Entry Delay 2 , Bell Duration Use ' to select full arm or part arm 1-3, $ - , to select arming an mode, " to accept $# Entry/Exit * Timed Exit ,# Deferred ! )# Exit Term. + Instant Use ' to select option 1, 2 or 3, press & to edit, $ - ( to select option, " to $ Auto Part Arm! + Time Arming CT1 . Tamper Eng Reset! ) Part Arm Silent! , Alarm Eng Reset! ( Anti-code Reset! * Remote Arm/Disarm! - Confirmation Reset! $ Arm With L/Fault! + Unarm Fire Coms . Confirm in Entry ) Arm With AC Fail , Unarm Tamper Coms ( Conf. After Entry * Part Arm Coms - Log Part Omits! Faults Eng Reset $# * AC Fail Eng Reset , FOB After Entry )# No ATS Eng Reset + Mask When Armed Global Options System Timers Use ' to select a timer, ! - % to enter a value, " to accept , Pulse Period 1! ' Soak Test Time Double Knock Dly! - Line Fault Delay! ' Service Interval ! Activity Delay AC Off Delay . ' Test Call Every ! ! Abort Delay! ( Batt Test Period! ' Quick Response ! Courtesy Time! Batt Test Time % ' Confirmation Dly System Config.! Use ' to select an option, & to change the option, " to accept ! $ ) * + Exit Settle Time! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! 00: (No Bell/Bell on) Arm Fail! ! ! ! ! ! Advisory Volume! $ Chime Volume! )#Number Of Re-Arms 15: Test Call = (Timed/Timed) Bell is an (SAB/SCB)! 16: Batt Test = (Timed/Disarm) 02: (Manual/Auto) BST/GMT! 17: Bell = (1st Alarm/2nd Alarm) 03: (Leave/Remove) Omits! 18: SNDR = (1st Alarm/2nd Alarm) 04: Away (Override/Enforce) Delay 19: Abort = (Eng. Reset/User Reset) 05: NVM is (Unlocked/Locked)! 20: 8XE = (Zones 9-16/Tampers 1-8) 06: Engineer (Only/+ User)! 21: (2nd Zone /1st Zone) = Confirm 07: Omit Tampers (NO/YES)! 22: Access (No Conf./= Confirm) 08: (80/40) Column Printer 23: EN50131 (Disabled/Enabled) 09: Activity Fault (View/Hide) 24: Panel Grade 2/Grade 3 10: (Hide/View) Exit Errors 25: RF PA (Disabled/Enabled) 11: (No/Enable) Code Tampers 26: Armed Mask = (Fault/Alarm) 12: Code Tamp (Alarms/Locks) 27: RF PA = (Audible/Silent) 13: Zone Short=(Active/Tamper) 28: Dynamic/Periodic Tests 14: R/R=(Reset Only/Silence/RST) 01: System Options! Use ' to select an Option, ! - % to enter a value, " to accept * + , # Anti-code Resets ! Quick Count Modem Level 5 Premier 24 Quick Reference & Factory Defaults Quick Reference Guide Global Options * *# # # # # ! ! ! ! +# Control Timers ,# System Text (# Speaker Tones + "# "# # # # # "# "# # # # # , "# # # # "# "# # # # 6 Monitor Hardware Press & to edit, ' to select an option, & to change the option, " to accept $ ) * + ATS Path Fault! , . # Mains Power Off Auxiliary Fuse Blown Bell Tamper Auxiliary Tamper Panel Lid Tamper Battery Fault Use ' to select an timer, ! - % to enter the 1st On time, " to accept Use $ - . to select the 1st On time days of operation, " to accept Use ! - % to enter the 1st Off time, " to accept Use $ - . to select the 1st Off time days of operation, " to accept Use ' to select a message, ! - % to select characters (press the required key the appropriate number of times), " to accept Use ' to select a tone type, & to turn the tone on/off, " to accept Keypad Setup Zone Mapping! Press & to edit, $ - ( to enter zone number, " to accept, Repeat for 2nd zone Options! Press & to edit, ' to select an option, & to change the option, " to accept , A = PA is Audible F = Fire Enabled! - D = PA is Delayed M = Medical Enabled! . Q = Quick Arm On T = Tamper Enabled! ( O = Info.LED>Output Volume! Press & to edit, ! - ( to enter a value, " to accept Sounder Options! Press & to edit, ' to select an option, & to change the option, " to accept $ F = Fire Tones Enabled! , E = Entry Tones Enabled ! A = Alarm Tones Enabled ) - X = Exit Tones Enabled ! ! * F = Fault Tones Enabled! . C = Chime Tones Enabled ! S = Service Tones Enabled + ! ! ! ! ! ! $ ) * + P = PA Enabled! Expander Setup Auxiliary Input! Press & to edit, !- . to select an input type, " to accept * Silence Sounders Auxiliary Tamper! + PSU Fault Bell Tamper! , Shunt Key Volume! Press & to edit, ! - ( to enter a value, " to accept Sounder Options! Press & to edit, ' to select an option, & to change the option, " to accept $ F = Fire Tones Enabled! , E = Entry Tones Enabled ! A = Alarm Tones Enabled ) - X = Exit Tones Enabled ! ! * F = Fault Tones Enabled! . C = Chime Tones Enabled ! S = Service Tones Enabled + ! ! ! ! ! ! $ ) Not Used! INS249 Premier 24 Quick Reference & Factory Defaults !# $# +# ,# -# Key !# $# # # # # # # # # # # # # # # # INS249 Quick Reference Guide System Outputs Panel Outputs Com? Channels Keypad Outputs Expander Outputs PGM Outputs Use $ - 7 to select an output, & to edit, $ - . to enter an output group, ! - % to enter output type, " to accept Use $ - ( to select keypad/expander, ! to select network, ' to select an output, & to edit, $ - . to enter an output group, ! - % to enter output type, " to accept Use ! to select output, $ - ( to select a switch, & to edit, $ - . to enter an output group, ! - % to enter output type, " to accept Output Group Not Used: System:! Outputs Types Press " to accept Use ! - % to enter an output type or use ' to search, " to accept 00: ATS Path Fault 15: 01: Mains Power Off 16: Digi Failed! 29:! Com Port 2 Fault 02: Aux Fuse Fault 17: 03: Auxiliary Tamper Digi Active! UDL Lockout! 31:! Prox TAG Accepted 18: 04: 05: Bell Tamper 18: UDL Lockout! 33: Detector Test Panel Lid Tamper 19: UDL Call Active! 34: ATS Remote Test ! 06: ! 07: Engineer Working 20: UDL Enabled 35: No ATS Available Confirm Devices 21: Custom Output 36: CIE Fault ! 08: Service Required 22: Activity Fault 37: PSU Fuse Blown ! 09: Shunt Active 23: No Battery 38: PSU Battery Flt ! 10: Battery Fault! 24: Control Timer 1 39: iD Loop Shorted ! 11: Control Timer 2 40: Radio Plus Tamper 12: Battery Test On! Courtesy Light! 25: ! 26: Control Timer 3 41: GSM No Signal ! 13: PC Output 1! 27: Control Timer 4 ! 14: PC Output 2! 28: Com Port 1 Fault ! Digi Successful! 30:! Code Accepted 32:! Radio Jamming 7 Premier 24 Quick Reference & Factory Defaults Quick Reference Guide Key )# # # # # # # # # # # # # # # # # # # # *# Output Group Alarm: ! 8 Use ! - % to enter an output type or use ' to search, " to accept 00: Alarm 19: 01: Guard Alarm 20: Entry/Exit Mode! 39: Zone On Test 02: Guard Access Alarm 21: Armed! 40: Test Fail 03: Entry Alarm 22: Internal Alarm Confirmed Alarm 23: Full Arm! Part Armed! 41: 04: 42: Time Arming 05: 24Hr Audible 24: Force Armable! 43: Part Armed 1 06: Forced Entry 25: Force Armed! 44: Part Armed 2 07: 24Hr Gas 26: Arm Fail! 45: Part Armed 3 Bell SAB! Strobe! 46: Zones Locked Out 47: Armed/Alarm 48: Full Entry Mode 49: Intruder Alarm 08: PA Audible 27: 09: PA Silent 28: Zone: Attributes "# Attributes! 38: Detector Latch! Detector Reset! DK First Knock Duress 29: 11: Fire Alarm! 30: 12: Medical Alarm! Auxiliary Alarm! 31: Walk Test Active! 50 Sounder Mimic 13: 32: Zones Omitted 51 Detector Fault 14: Tamper Alarm! 33: 24Hr Zones Omit 52 Detector Masked 15: Alarm Abort! 34: Reset Required 53 Fault Present 16: Ready! 35: Door Strike 54 LED Control 17: Entry Mode! 2nd Entry Mode! 36: Chime Mimic 37: Chime Enabled Use ! - % to enter an output type or use ' to search, " to accept 01 – 24 Key Exit Mode! 10: 18: # # # Outputs Types Zone 1 to 24 Mimic 25 – 48 Zone 1 to 24 Alarm Attribute Types Press " to edit, $ - + to select attributes, " to accept $ ) User Test = U Inverted = I * + Latch Until = L Use Pulse Timer 1 =1! INS249 Premier 24 Quick Reference & Factory Defaults Quick Reference Guide UDL/Digi Options . !#Reset Digi $#Start Test Call Press / to reset digimodem *#Program Digi Use $ - ) to select ARC 1 – 2, & to edit Press " to send test call to the ARC, $ - ) to initiate a call to the remote UDL computer (using Call Back numbers 1, 2 or 3) Press & to edit, ! - + to select protocol, " to accept # # # # Protocol # # # Telephone N b Account Number Press & to edit telephone number 2, ! - % to enter the number, " to accept Dialling Attempts Press & to edit, ! - % to enter number, " to accept Reporting Ch l Restoring Ch l Open/Close Ch l Reporting Options Press & to edit, $ - ( to select channels, " to accept (only for Fast Format) # # # # # # # # # Telephone Number 1 Config. # # # ,#UDL Options Call Back Number 1 . # Press & to edit, ! - % to enter number, " to accept Press & to edit, $ - ( to select channels, " to accept (only for Fast Format) Press & to edit, $ - ( to select channels, " to accept (only for Fast Format) Press & to edit, $ - ( to select option, " to accept (only available for Contact ID, SIA Level II, EasyCom Pager and SMS Messaging) P = Priority Alarms , . ( A = Normal Alarms C = Open/Close O = Omits & Reinstates M = Maintenance T = Tamper C = Test Calls R = Restores Press & to edit, $ - ( to select option, " to accept (only available for Contact ID, SIA Level II, EasyCom Pager & SMS Messaging) D = Disable Zone $ * R = Enable RadioPad , F =Use S = Use SIA I ) + G = Enable GSM Press & to edit, ' to select an option, & to change the option, " to accept B = Blind Dialling E = Digi is Enabled $ + P = Pulse Dialling R = Reserved ) , 3 = Pulse after 3 A = Dial All * Press & to edit, ! - % to enter the number, " to accept, pressing & repeatedly Inserts a *#,(3 second pause)W(10 second pause)+R(recall signal) Call Back N b UDL Password Press & to edit call back number 2, ! - % to enter the number, " to accept UDL options Press & to edit, ' to select an option, & to change option, " to accept # # # # # Inserts a *#,(3 second pause)W(10 second pause)+R(recall signal) $ ) * + # # +#Digi Options # # # Disabled !# ) Contact ID + SMS Fast Format * SIA Level II $! Press & to edit, ! - % to enter the number, " to accept, pressing & repeatedly Number of Rings Dialling Attempts Radio/SMS Option # # Press & to edit, ! - % to enter number, " to accept A = DL Attended L = Armed DL $ + M = Manual Call-back A = Only Full ) , D = Call Defeat On K = Online * Press & to edit, ! - % to enter number of rings, " to accept Press & to edit, ! - % to enter number of dialling attempts, " to accept Use ' to select option, & to edit, ! - % to enter numbers, " to accept 1:! Pad ARC1 Pri 4:! Pad ARC2 Pri 2:! Pad ARC1 Sec 5:! Pad ARC2 Sec 3:! Pad ARC1 Prefix 6:! Pad ARC2 Prefix 7:! SMS Centre Pi 8:! SMS Centre S # # INS249 9 Premier 24 Quick Reference & Factory Defaults Quick Reference Guide UDL/Digi Options continued # ( Com Port Setup Use ! - ) to select a com port, & to edit, ' to select an option, " to accept # Options depend on com port Com300 # Nothing Fitted User Code Use ! - % to enter a code, " to accept User Types Use ! - % to select a user type, " to accept ! Engineer * Standard $ ) " # # # # "# # # # # Radio Pad Radio Plus GSM Module Setup Users ( " " Com2400 ComISDN# User Options 1 (only available to Custom users) User Text ! ! ! % !# View System Log Master Manager + , Shunt . Reset Only Door Strike Duress Press & to edit, ' to select an option, & to change option, " to accept $ ) * + Arming , . ( Disarming Omitting Lock TAG by PGM2 Lock CODE by PGM3 Lock USER by PGM4 Auto ‘YES’ Send Open/Close Press & to edit, ! - % to select characters (press the required key the appropriate number of times), " to accept $ ) * + .,?!1@“ABC2 DEF3 GHI4 , . ( JKL5 MNO6 PQRS7 % ! ' WXYZ9 0_ Move Cursor TUV8 Engineer Utils Use ' to move up and down through log (down moves back in time, up moves forward again), 0 to show other information $ - ( to find specific events Use ' to select an option, use $ - ( or " to activate outputs $# Do Bell Test )# Do Walk Test *# View Zone Status Use ! - % to enter zone number or use ' to search, 2 to walk test selected zone, 3 to omit zone temporarily +# ,# -# .# View Version No. Confirm Devices Check RKP Status Check Exp. Status Press " to view hardware information Use ' to select network, " to confirm Devices Use $ - + to select keypad, & to test output, 3 to test sounder, Use $ - ) to select expander, ! to select network, 1 to display zones/voltage/outputs, 2 to test zones, 3 to test sounder, $ - ( to test outputs (# %# '# Set System Time Set System Date Change Eng Code Use ! - % to enter time (24-hour format) 4455, " to accept Use ! - % to enter date 665577, " to accept Use ! - % to enter a code, " to accept 1: Test Bell 5: LCD Display 2: Test Strobe 6: Test Panel 3: Test Speaker 7: Test Comms 4: User Outputs Press 1 to display zones that have been tested/still need testing, 2 to make zones Chime every time they are activated. Alter Part Arms 0 # Press ! - % to enter zone number or use ' to search, 3, 2 or 0 to select Part Arms 1, 2 or 3 2 Part Arm 2 0 Part Arm 3 # 3 Part Arm 1 10 INS249 Premier 24 Quick Reference & Factory Defaults INS249 Notes 11 Texecom Limited, Bradwood Court, St. Crispin Way, Haslingden, Lancashire BB4 4PW, England. Technical Support: UK Customers Tel: 08456 300 600 (Calls charged at 3.36 pence per minute from a BT landline. Calls from other networks may vary.) International Customers Tel: +44 1278 411707 Email: [email protected] © Texecom Limited 2007 INS249-2