Download Operating Instructions Model: JG STATPLUS/TS/V3

Transcript
Operating Instructions
Model:
JG STATPLUS/TS/V3
10/09 Revision 1
Ref: JGSTATPLUS/TS/V3
the nation’s favourite for
PLUMBING & HEATING SUPPLIES
FREE SHIPPING
SECURE PAYMENTS
on all orders over £100 to mainland UK
shop online with confidence
FINANCE AVAILABLE
PRICE MATCH
spread the cost with low interest rates
always get the best deals available
we have
H U G E
R E D U C T I O N S
ON THOUSANDS OF ITEMS
Boilers
Bathroom suites
Radiators
Kitchen sinks & taps
Heating controls
Showers
Pipes & ittings
Wet rooms
Cylinders
Towel warmers
Fires
Bathroom furniture
Renewable energy
& much more
visit our website
plumbnation.co.uk
CALL US ON
0844
800
3460
Contents Page
DisplaySymbolsExplained
TemperatureDisplay
SettingtheClock
ComfortLevelsExplained
SettingtheHotwaterSwitchingTimes
LockingtheKeypad
TemperatureOverride
TemperatureHold
HowaterOverride
Holiday
HeatOn/Off
CleanScreen
FactoryReset
OptionalFeatureSetup
WiringDiagrams
1
7
8
8
9-11
12-13
13
14
14
15
16
17
17
18
19-23
24-25
What is a programmable room thermostat ?
Aprogrammableroomthermostatisbothaprogrammer
andaroomthermostat.Aprogrammerallowsyoutoset
“On”and“Off”timeperiodstosuityourownlifestyle.A
roomthermostatworksbysensingtheairtemperature,
switchingontheheatingwhentheairtemperaturefalls
belowthethermostatsetting,andswitchingitoffoncethis
settemperaturehasbeenreached.
So,aprogrammableroomthermostatletsyouchoosewhat
timesyouwanttheheatingtobeon,andwhattemperature
itshouldreachwhileitison.Itwillallowyoutoselect
differenttemperaturesinyourhomeatdifferenttimesofthe
day(anddaysoftheweek)tomeetyourparticularneeds.
Turningaprogrammableroomthermostattoahighersetting
willnotmaketheroomheatupanyfaster.Howquickly
theroomheatsupdependsonthedesignoftheheating
system,forexample,thesizeoftheboilerandradiators.
Neitherdoesthesettingaffecthowquicklytheroomcools
2
down.Turningaprogrammableroomthermostattoalower
settingwillresultintheroombeingcontrolledatalower
temperature,andsavesenergy.
Thewaytosetanduseyourprogrammableroom
thermostatistoindthelowesttemperaturesettingsthat
youarecomfortablewithatthedifferenttimesyouhave
chosen,andthenleaveitalonetodoitsjob.
Thebestwaytodothisistosetlowtemperaturesirst,say
18ºC,andthenturnthemupbyonedegreeeachdayuntil
youarecomfortablewiththetemperatures.Youwon’thave
toadjustthethermostatfurther.Anyadjustmentabove
thesesettingwillwasteenergyandcostyoumoremoney.
Ifyourheatingsystemisaboilerwithradiators,there
willusuallybeonlyoneprogrammableroomthermostat
tocontrolthewholehouse.Butyoucanhavedifferent
temperaturesinindividualroomsbyinstallingthermostatic
radiatorvalves(TRVs)onindividualradiators.Ifyoudon’t
haveTRVs,youshouldchooseatemperaturethatis
reasonableforthewholehouse.IfyoudohaveTRVs,you
3
canchooseaslightlyhighersettingtomakesurethat
eventhecoldestroomiscomfortable,thenpreventany
overheatinginotherroomsbyadjustingtheTRVs.
Thetimeontheprogrammermustbecorrect.Sometypes
havetobeadjustedinspringandautumnatthechanges
betweenGreenwichMeanTimeandBritishSummerTime.
Youmaybeabletotemporarilyadjusttheheating
programme,forexample,“Override”,“Advance”or“Boost”.
Theseareexplainedinthemanufacturer’sinstructions.
Programmableroomthermostatsneedafreelowofair
tosensethetemperature,sotheymustnotbecovered
bycurtainsorblockedbyfurniture.Nearbyelectricires,
televisions,wallortablelampsmaypreventthethermostat
fromworkingproperly.
4
Installation Procedure
DO’s
1. Domountthethermostatateyelevel.
2. Doreadtheinstructionsfullysothatyougetthebest
fromourproduct.
DON’Ts
1. Donotinstallnearadirectheatsourceasthiswillaffect
theworkingsofthethermostat.
2. DonotpushhardontheLCDotherwiseyouwilldamage
theliquidcrystaldisplayandthisisnotrepairable.
Installation
Thethermostatisdesignedtobelushmount,aback
boxof35mmshouldhavebeensunkinthewallpriorto
installation.
Step1
Carefullyseparatethefronthalfofthethermostatfromthe
backplatebyplacingasmalllatheadterminaldriverinto
theslotsonthebottomfaceofthethermostat.
5
Step2
Carefullyunplugtheribbonconnectorwhichispluggedinto
thefronthalfofthethermostat.
Placethethermostatfronthalfsomewheresafe.Terminate
thethermostatasshowninthediagramsatthebackofthis
booklet.
Screwthethermostatbackplateontothebackbox
Step3
Re-connectthethermostatribboncableandclipthetwo
halvestogether.
6
Display Symbols Explained
Symbol
Description
Heat On Icon
Shown when the heating is On
Flashing When the optimum start is in operation.
HW ON
HW ON / HW OFF
HW OFF Shown to indicate whether the hot water output
ison or off
Frost On Icon (Heating Off)
Shown when the heating is switched off and is
protecting against frost only
Keylock Icon
Shown when the keypad is locked
7
Temperature Display
Room Temp
Thisisthecurrentroomtemperature.
SET=Thisisthetemperatureyouaretryingtoachievein
yourhome.
HW ON / HW OFF=Thisisthestatusofthehotwater.
Setting The Clock
Tosettheclockinyourthermostat,followthestepsbelow:
•
•
•
•
•
Withthethermostatturnedon,pressPROG
PressClock
UsetosetthecorrectTime
PressDaytosetthecorrectDay
PressDonetoacceptandstore
8
Comfort Levels Explained
Comfortlevelsallowyoutosetdifferenttemperatures
throughouttheday.Forexample,youmaywantthehome
warminthemorningwhenyouaregettingreadyforwork,
coolerduringthedaywhenthehouseisunoccupiedand
thenwarmerintheeveningwhenyouarehomerelaxing.
Thethermostatoffers5/2DayProgramming(4levelsfor
theweekday,4fortheweekend)and7dayProgramming(4
levelsforeachday).Seepages19-23fordetailsonhowto
switchbetweenthesemodes.
Tip !Ifyoudon’twanttouseallofthecomfortlevels,just
setthetimeto--.—andthethermostatwillignorethis
setting.
9
Factory Programmed Comfort Levels
Thefollowingcomfortlevelsareprogrammedalready,
howeveryoucanchangethemeasily.
Weekday Level
Wake
Leave
Return Sleep
Time
07.00
09.00
16.00
22.00
Temp
21°C
16°C
21°C
16°C
Weekend Level
Wake
Leave
Return Sleep
Time
09.00
22.00
--.--
--.--
Temp
21°C
16°C
--°C
--°C
10
Changing the Comfort Levels
• PressPROGandselectWake
• Usetosetthetimeforthe1stComfortlevel
• Usetosetthetemperaturein°C
• YoushouldnowrepeatfortheLeave,Return&Sleep
levels.
• PressDaytoselectthenextday.In5/2daymodethe
thermostatwillhighlight“SatSun”promptingyouto
programthetemperaturelevelsfortheweekend.In7day
mode,thethermostatwillhighlightTuesday.
• Whencomplete,pressDonetoStoreandExit.
11
Hot Water Timings Explained
TheJGSTATPLUS/TS/V3offersanadditionaltimedoutput
forthehotwatercylinder.Thethermostatoffers5/2Day
Programming(4levelsfortheweekday,4fortheweekend)
and7dayProgramming(4levelsforeachday).Seepages
19-23fordetailsonhowtoswitchbetweenthesemodes.
Factory Programmed Hot Water Times
Thefollowinghotwaterswitchingtimesareprogrammed
already;howeveryoucanchangethemeasily.
Weekday
Wake
Leave
Return Sleep
On Time
07.00
16.00
--.--
--.--
Off Time
09.00
20.00
--.--
--.--
Weekend
Wake
Leave
Return Sleep
Time
07.00
16.00
--.--
--.--
Temp
09.00
20.00
--.---.--
12
Changing the Hot Water Times
•
•
•
•
PressPROGandselectTimer
YouwillseeTIME1andONlash
Usetosettheontimeforthe1stswitchingtime
PressOffandthenusetosettheoffswitching
time.
• YoushouldnowrepeatfortheTime2-4
• PressDaytoselectthenextday.In5/2daymodethe
thermostatwillhighlight“SatSun”promptingyouto
programtheswitchingtimesfortheweekend.In7day
mode,thethermostatwillhighlightTuesday.
• Whencomplete,pressDonetoStoreandExit.
Locking the Keypad
Thethermostathasakeylockfacility.Toenablethispress
thebottomrightcornerofthedisplayandholdfor10
seconds.
Whenactivated,youwillsee.
Tocancel,repeatthestepsabove.
13
Temperature Override
Usingthekeysallowsyoutoadjusttheset
temperature.Whenyoupresseitherofthesekeys,youwill
seethewordSETandthedesiredtemperature.PressDone
toaccept.
Thissettemperatureistemporaryandishelduntilthenext
programmedcomfortlevel.
Temperature Hold
TheTemperatureHoldfunctionisidealforpartiesorwhen
youwillbegoingoutforanumberofhours.Itallowsyouto
holdatemperatureforadesiredperiod.
•
•
•
•
PressHOLD
SetthedesiredHoldtimeandtemperature
PressDone
TocancelaHoldtime,reducethetimeto00.00
14
Hot Water Override
Thethermostathasanoverridefunctionforthehotwater
outputallowingyoutooverridethehotwaterintothe
oppositestate.
•
•
•
•
PressHold
PressTimer
IfthehotwaterisalreadyOn–pressOff
IfthehotwaterisalreadyOff–pressOn
Youwillthenseethehotwaterstatuschangeandthe
hotwateroutputindicationwilllashtoshowithasbeen
overriddenfromtheprogrammedsetting.
Thehotwaterwillremainintheoverridestateuntilthenext
programmedtime.Tocancel,repeatthestepsabove.
15
Holiday
TheHolidayfunctionreducesthesettemperatureinyour
hometothefrosttemperaturesetting.Thethermostatwill
maintainthistemperatureforthedurationoftheholidayand
willthenautomaticallyreturntotheprogrammodeonyour
return.
AssumeyouprogramaholidayonMondayfor1day,the
holidaywillstartimmediately,butthethermostatwillcount
thenextday(Tuesday)astheholiday.Thethermostatwill
thenrevertbacktoitsprogramatmidnightTuesday.
•
•
•
•
PressHOLIDAY
Enterthedurationofyourholiday
PressDone
TocancelaHoliday,reducetheHolidaytimeto00days.
Duringaholidayprogramthehot-wateroutputisturnedoff.
16
Heat On / Off
Frost Protect Mode:PressingtheOffbuttononcewill
placethethermostatinfrostprotectmode.Inthismode,
thethermostatwilldisplaythefrosticonandwillonlyturn
theheatingonshouldtheroomtemperaturedropbelowthe
setfrosttemperature(seepages19-23).Shouldtheheating
beturnedonwhilstinfrostmode,thelamesymbolwillbe
displayed.Tocancelthefrostprotectmode,presstheOn
button.
Thermostat Off:Toturnthethermostatoffcompletely,
pressandholdtheOffbutton.Thedisplayandheating
outputwillbeturnedoff.Toturnthethermostatbackon,
presstheOnbutton.
Clean Screen
PressingCleanScreenwilldisableallbuttons,allowingyou
30secondstowipethescreenclean.
17
Factory Reset
Thethermostathasafactoryresetfunction.Thiswillreset
allsettingsbacktotheirfactorydefault.
Toperformafactoryreset,followthesesteps:
Turnoffthethermostatbypressingtheoffbutton.
PressandholdthebottomleftcorneroftheLCDfor10
seconds.Youwillseealltheiconsappearfor2seconds
andthendisappear.Thethermostathasthenbeenresetto
thefactorydefaults.
18
THE FOLLOWING SETTINGS ARE OPTIONAL
AND IN MOST CASES NEED NOT BE ADJUSTED
Optional Features Explained
Feature 01 – Temperature Format:Thisfunctionallows
youtoselectbetween°Cor°F.
Feature 02 - Switching Differential:Thisfunctionallows
youtoincreasetheswitchingdifferentialofthethermostat.
Thedefaultis1°Cwhichmeansthethermostatwillswitch
theheatingon0.5°Cbelowthesettemperatureandwill
turnitoff0.5°Cabovethesettemperature.Witha2°C
differential,theheatingwillswitchon1.5°Cbelowthe
settemperatureandwillswitchoff0.5°Cabovetheset
temperature.
Feature 03 - Frost Protect:Youcansetwhetherthe
thermostatwillmaintainthefrosttemperaturewhen
thethermostatdisplayisturnedoff.Asadefault,thisis
enabled.
19
Feature 04 – Frost Protect Temperature:Thisisthe
temperaturemaintainedwhenthethermostatisinfrost
mode.Therangeis07-17°C.Thedefaultis12°Candis
suitableforalmostallapplications.
Feature 05 – Output Delay:Topreventrapidswitching,an
outputdelaycanbeentered.Thiscanbesetfrom00-15
minutes.Thedefaultis00whichmeansthereisnodelay.
Feature 06 – Communication Address:Thissetting
isusedwhenyouhaveconnectedyourthermostattoa
networksystem.Eachthermostatonthenetworkmusthave
auniquecommunicationaddress.Thiscanbesetfrom
01-32.
Feature 07 – Temperature Up/Down Limit:Thisfunction
allowsyoutolimittheuseoftheupanddowntemperature
arrowkeys.Thislimitisalsoapplicablewhenthethermostat
islockedandsoallowsyoutogiveotherslimitedcontrol
overtheheatingsystem.
Feature 08 – Sensor Selection:Thisthermostathasabuilt
inairsensoronly.
20
Feature 09 – Floor Limit Sensor:Thisfunctionisnotused
onthismodel.
Feature 10 – Optimum Start:Optimumstartwillbringthe
heatingonearlyifneeded,sothehouseiswarmwhenyou
wakeup.Thismeansyoudon’tneedtoallowanyextra
heatuptimewhenprogrammingthecomfortlevels.The
thermostatwillautomaticallylearntherequiredheatuptime
andwilladjustitself,ifrequired,throughouttheyear.
Feature 11 – Rate Of Change:Thisisthenumberof
minutesthethermostathascalculatedittakestoraiseyour
building1°C.Thethermostatwillcontinuetolearntheheat
uptimeofyourhomeandwilladjustthissettingtosuit.
Feature 12 – 5/2 Day, 7 Day Programmable:This
functionallowsyoutoswitchbetween5/2dayor7day
programming.5/2daymeansyoucanprogram4comfort
levelsfortheweekdayand4differentlevelsforthe
weekend.7dayprogrammingallowsyoutoprogram4
temperaturelevelsforeachdayoftheweek.
21
Adjusting the Optional Settings
Toadjustthesettings,followthesesteps:
•
•
•
•
Withthethermostatturnedon
PressPROG
PressSETUP
Usetheatthetopofthescreentoselectthe
featurenumber(shownonpage23)andthenusethe
keysinthecentreadjustthesetting.
• PressDonetoacceptandStore
22
Feature Table
Description
Setting
Feature
01
°C/°F
TemperatureFormat
02
Switching
Differential
01=1°C02=2°C3=3°C
1°C=Default
03
FrostProtect
00=Disabled01=Enabled
(01=Default)
04
FrostTemp
05
OutputDelay
Entervalue
00-15minutes(00=Default)
06
Comms#
Enternumber01-32
07
TempLimit
00-10°C
10
OptimumStart
00=Disabled(Default)
01=01hr02=02hr03=03hr
11
RateofChange
Forinformationonly
12
5/2Day
7Day
07-17°C(12=Default)
00Default
01
23
JGSTATPLUS/TS/V3 Model
THE JGSTATPLUS/TS/V3
CONNECTED TO
THE UH1
24
JGSTATPLUS/TS/V3 Model
THE JGSTATPLUS/TS/V3
25
SupportTel:01254870303