Download Operating Instructions Model: JG STATPLUS/TS/V3
Transcript
Operating Instructions Model: JG STATPLUS/TS/V3 10/09 Revision 1 Ref: JGSTATPLUS/TS/V3 the nation’s favourite for PLUMBING & HEATING SUPPLIES FREE SHIPPING SECURE PAYMENTS on all orders over £100 to mainland UK shop online with confidence FINANCE AVAILABLE PRICE MATCH spread the cost with low interest rates always get the best deals available we have H U G E R E D U C T I O N S ON THOUSANDS OF ITEMS Boilers Bathroom suites Radiators Kitchen sinks & taps Heating controls Showers Pipes & ittings Wet rooms Cylinders Towel warmers Fires Bathroom furniture Renewable energy & much more visit our website plumbnation.co.uk CALL US ON 0844 800 3460 Contents Page DisplaySymbolsExplained TemperatureDisplay SettingtheClock ComfortLevelsExplained SettingtheHotwaterSwitchingTimes LockingtheKeypad TemperatureOverride TemperatureHold HowaterOverride Holiday HeatOn/Off CleanScreen FactoryReset OptionalFeatureSetup WiringDiagrams 1 7 8 8 9-11 12-13 13 14 14 15 16 17 17 18 19-23 24-25 What is a programmable room thermostat ? Aprogrammableroomthermostatisbothaprogrammer andaroomthermostat.Aprogrammerallowsyoutoset “On”and“Off”timeperiodstosuityourownlifestyle.A roomthermostatworksbysensingtheairtemperature, switchingontheheatingwhentheairtemperaturefalls belowthethermostatsetting,andswitchingitoffoncethis settemperaturehasbeenreached. So,aprogrammableroomthermostatletsyouchoosewhat timesyouwanttheheatingtobeon,andwhattemperature itshouldreachwhileitison.Itwillallowyoutoselect differenttemperaturesinyourhomeatdifferenttimesofthe day(anddaysoftheweek)tomeetyourparticularneeds. Turningaprogrammableroomthermostattoahighersetting willnotmaketheroomheatupanyfaster.Howquickly theroomheatsupdependsonthedesignoftheheating system,forexample,thesizeoftheboilerandradiators. Neitherdoesthesettingaffecthowquicklytheroomcools 2 down.Turningaprogrammableroomthermostattoalower settingwillresultintheroombeingcontrolledatalower temperature,andsavesenergy. Thewaytosetanduseyourprogrammableroom thermostatistoindthelowesttemperaturesettingsthat youarecomfortablewithatthedifferenttimesyouhave chosen,andthenleaveitalonetodoitsjob. Thebestwaytodothisistosetlowtemperaturesirst,say 18ºC,andthenturnthemupbyonedegreeeachdayuntil youarecomfortablewiththetemperatures.Youwon’thave toadjustthethermostatfurther.Anyadjustmentabove thesesettingwillwasteenergyandcostyoumoremoney. Ifyourheatingsystemisaboilerwithradiators,there willusuallybeonlyoneprogrammableroomthermostat tocontrolthewholehouse.Butyoucanhavedifferent temperaturesinindividualroomsbyinstallingthermostatic radiatorvalves(TRVs)onindividualradiators.Ifyoudon’t haveTRVs,youshouldchooseatemperaturethatis reasonableforthewholehouse.IfyoudohaveTRVs,you 3 canchooseaslightlyhighersettingtomakesurethat eventhecoldestroomiscomfortable,thenpreventany overheatinginotherroomsbyadjustingtheTRVs. Thetimeontheprogrammermustbecorrect.Sometypes havetobeadjustedinspringandautumnatthechanges betweenGreenwichMeanTimeandBritishSummerTime. Youmaybeabletotemporarilyadjusttheheating programme,forexample,“Override”,“Advance”or“Boost”. Theseareexplainedinthemanufacturer’sinstructions. Programmableroomthermostatsneedafreelowofair tosensethetemperature,sotheymustnotbecovered bycurtainsorblockedbyfurniture.Nearbyelectricires, televisions,wallortablelampsmaypreventthethermostat fromworkingproperly. 4 Installation Procedure DO’s 1. Domountthethermostatateyelevel. 2. Doreadtheinstructionsfullysothatyougetthebest fromourproduct. DON’Ts 1. Donotinstallnearadirectheatsourceasthiswillaffect theworkingsofthethermostat. 2. DonotpushhardontheLCDotherwiseyouwilldamage theliquidcrystaldisplayandthisisnotrepairable. Installation Thethermostatisdesignedtobelushmount,aback boxof35mmshouldhavebeensunkinthewallpriorto installation. Step1 Carefullyseparatethefronthalfofthethermostatfromthe backplatebyplacingasmalllatheadterminaldriverinto theslotsonthebottomfaceofthethermostat. 5 Step2 Carefullyunplugtheribbonconnectorwhichispluggedinto thefronthalfofthethermostat. Placethethermostatfronthalfsomewheresafe.Terminate thethermostatasshowninthediagramsatthebackofthis booklet. Screwthethermostatbackplateontothebackbox Step3 Re-connectthethermostatribboncableandclipthetwo halvestogether. 6 Display Symbols Explained Symbol Description Heat On Icon Shown when the heating is On Flashing When the optimum start is in operation. HW ON HW ON / HW OFF HW OFF Shown to indicate whether the hot water output ison or off Frost On Icon (Heating Off) Shown when the heating is switched off and is protecting against frost only Keylock Icon Shown when the keypad is locked 7 Temperature Display Room Temp Thisisthecurrentroomtemperature. SET=Thisisthetemperatureyouaretryingtoachievein yourhome. HW ON / HW OFF=Thisisthestatusofthehotwater. Setting The Clock Tosettheclockinyourthermostat,followthestepsbelow: • • • • • Withthethermostatturnedon,pressPROG PressClock UsetosetthecorrectTime PressDaytosetthecorrectDay PressDonetoacceptandstore 8 Comfort Levels Explained Comfortlevelsallowyoutosetdifferenttemperatures throughouttheday.Forexample,youmaywantthehome warminthemorningwhenyouaregettingreadyforwork, coolerduringthedaywhenthehouseisunoccupiedand thenwarmerintheeveningwhenyouarehomerelaxing. Thethermostatoffers5/2DayProgramming(4levelsfor theweekday,4fortheweekend)and7dayProgramming(4 levelsforeachday).Seepages19-23fordetailsonhowto switchbetweenthesemodes. Tip !Ifyoudon’twanttouseallofthecomfortlevels,just setthetimeto--.—andthethermostatwillignorethis setting. 9 Factory Programmed Comfort Levels Thefollowingcomfortlevelsareprogrammedalready, howeveryoucanchangethemeasily. Weekday Level Wake Leave Return Sleep Time 07.00 09.00 16.00 22.00 Temp 21°C 16°C 21°C 16°C Weekend Level Wake Leave Return Sleep Time 09.00 22.00 --.-- --.-- Temp 21°C 16°C --°C --°C 10 Changing the Comfort Levels • PressPROGandselectWake • Usetosetthetimeforthe1stComfortlevel • Usetosetthetemperaturein°C • YoushouldnowrepeatfortheLeave,Return&Sleep levels. • PressDaytoselectthenextday.In5/2daymodethe thermostatwillhighlight“SatSun”promptingyouto programthetemperaturelevelsfortheweekend.In7day mode,thethermostatwillhighlightTuesday. • Whencomplete,pressDonetoStoreandExit. 11 Hot Water Timings Explained TheJGSTATPLUS/TS/V3offersanadditionaltimedoutput forthehotwatercylinder.Thethermostatoffers5/2Day Programming(4levelsfortheweekday,4fortheweekend) and7dayProgramming(4levelsforeachday).Seepages 19-23fordetailsonhowtoswitchbetweenthesemodes. Factory Programmed Hot Water Times Thefollowinghotwaterswitchingtimesareprogrammed already;howeveryoucanchangethemeasily. Weekday Wake Leave Return Sleep On Time 07.00 16.00 --.-- --.-- Off Time 09.00 20.00 --.-- --.-- Weekend Wake Leave Return Sleep Time 07.00 16.00 --.-- --.-- Temp 09.00 20.00 --.---.-- 12 Changing the Hot Water Times • • • • PressPROGandselectTimer YouwillseeTIME1andONlash Usetosettheontimeforthe1stswitchingtime PressOffandthenusetosettheoffswitching time. • YoushouldnowrepeatfortheTime2-4 • PressDaytoselectthenextday.In5/2daymodethe thermostatwillhighlight“SatSun”promptingyouto programtheswitchingtimesfortheweekend.In7day mode,thethermostatwillhighlightTuesday. • Whencomplete,pressDonetoStoreandExit. Locking the Keypad Thethermostathasakeylockfacility.Toenablethispress thebottomrightcornerofthedisplayandholdfor10 seconds. Whenactivated,youwillsee. Tocancel,repeatthestepsabove. 13 Temperature Override Usingthekeysallowsyoutoadjusttheset temperature.Whenyoupresseitherofthesekeys,youwill seethewordSETandthedesiredtemperature.PressDone toaccept. Thissettemperatureistemporaryandishelduntilthenext programmedcomfortlevel. Temperature Hold TheTemperatureHoldfunctionisidealforpartiesorwhen youwillbegoingoutforanumberofhours.Itallowsyouto holdatemperatureforadesiredperiod. • • • • PressHOLD SetthedesiredHoldtimeandtemperature PressDone TocancelaHoldtime,reducethetimeto00.00 14 Hot Water Override Thethermostathasanoverridefunctionforthehotwater outputallowingyoutooverridethehotwaterintothe oppositestate. • • • • PressHold PressTimer IfthehotwaterisalreadyOn–pressOff IfthehotwaterisalreadyOff–pressOn Youwillthenseethehotwaterstatuschangeandthe hotwateroutputindicationwilllashtoshowithasbeen overriddenfromtheprogrammedsetting. Thehotwaterwillremainintheoverridestateuntilthenext programmedtime.Tocancel,repeatthestepsabove. 15 Holiday TheHolidayfunctionreducesthesettemperatureinyour hometothefrosttemperaturesetting.Thethermostatwill maintainthistemperatureforthedurationoftheholidayand willthenautomaticallyreturntotheprogrammodeonyour return. AssumeyouprogramaholidayonMondayfor1day,the holidaywillstartimmediately,butthethermostatwillcount thenextday(Tuesday)astheholiday.Thethermostatwill thenrevertbacktoitsprogramatmidnightTuesday. • • • • PressHOLIDAY Enterthedurationofyourholiday PressDone TocancelaHoliday,reducetheHolidaytimeto00days. Duringaholidayprogramthehot-wateroutputisturnedoff. 16 Heat On / Off Frost Protect Mode:PressingtheOffbuttononcewill placethethermostatinfrostprotectmode.Inthismode, thethermostatwilldisplaythefrosticonandwillonlyturn theheatingonshouldtheroomtemperaturedropbelowthe setfrosttemperature(seepages19-23).Shouldtheheating beturnedonwhilstinfrostmode,thelamesymbolwillbe displayed.Tocancelthefrostprotectmode,presstheOn button. Thermostat Off:Toturnthethermostatoffcompletely, pressandholdtheOffbutton.Thedisplayandheating outputwillbeturnedoff.Toturnthethermostatbackon, presstheOnbutton. Clean Screen PressingCleanScreenwilldisableallbuttons,allowingyou 30secondstowipethescreenclean. 17 Factory Reset Thethermostathasafactoryresetfunction.Thiswillreset allsettingsbacktotheirfactorydefault. Toperformafactoryreset,followthesesteps: Turnoffthethermostatbypressingtheoffbutton. PressandholdthebottomleftcorneroftheLCDfor10 seconds.Youwillseealltheiconsappearfor2seconds andthendisappear.Thethermostathasthenbeenresetto thefactorydefaults. 18 THE FOLLOWING SETTINGS ARE OPTIONAL AND IN MOST CASES NEED NOT BE ADJUSTED Optional Features Explained Feature 01 – Temperature Format:Thisfunctionallows youtoselectbetween°Cor°F. Feature 02 - Switching Differential:Thisfunctionallows youtoincreasetheswitchingdifferentialofthethermostat. Thedefaultis1°Cwhichmeansthethermostatwillswitch theheatingon0.5°Cbelowthesettemperatureandwill turnitoff0.5°Cabovethesettemperature.Witha2°C differential,theheatingwillswitchon1.5°Cbelowthe settemperatureandwillswitchoff0.5°Cabovetheset temperature. Feature 03 - Frost Protect:Youcansetwhetherthe thermostatwillmaintainthefrosttemperaturewhen thethermostatdisplayisturnedoff.Asadefault,thisis enabled. 19 Feature 04 – Frost Protect Temperature:Thisisthe temperaturemaintainedwhenthethermostatisinfrost mode.Therangeis07-17°C.Thedefaultis12°Candis suitableforalmostallapplications. Feature 05 – Output Delay:Topreventrapidswitching,an outputdelaycanbeentered.Thiscanbesetfrom00-15 minutes.Thedefaultis00whichmeansthereisnodelay. Feature 06 – Communication Address:Thissetting isusedwhenyouhaveconnectedyourthermostattoa networksystem.Eachthermostatonthenetworkmusthave auniquecommunicationaddress.Thiscanbesetfrom 01-32. Feature 07 – Temperature Up/Down Limit:Thisfunction allowsyoutolimittheuseoftheupanddowntemperature arrowkeys.Thislimitisalsoapplicablewhenthethermostat islockedandsoallowsyoutogiveotherslimitedcontrol overtheheatingsystem. Feature 08 – Sensor Selection:Thisthermostathasabuilt inairsensoronly. 20 Feature 09 – Floor Limit Sensor:Thisfunctionisnotused onthismodel. Feature 10 – Optimum Start:Optimumstartwillbringthe heatingonearlyifneeded,sothehouseiswarmwhenyou wakeup.Thismeansyoudon’tneedtoallowanyextra heatuptimewhenprogrammingthecomfortlevels.The thermostatwillautomaticallylearntherequiredheatuptime andwilladjustitself,ifrequired,throughouttheyear. Feature 11 – Rate Of Change:Thisisthenumberof minutesthethermostathascalculatedittakestoraiseyour building1°C.Thethermostatwillcontinuetolearntheheat uptimeofyourhomeandwilladjustthissettingtosuit. Feature 12 – 5/2 Day, 7 Day Programmable:This functionallowsyoutoswitchbetween5/2dayor7day programming.5/2daymeansyoucanprogram4comfort levelsfortheweekdayand4differentlevelsforthe weekend.7dayprogrammingallowsyoutoprogram4 temperaturelevelsforeachdayoftheweek. 21 Adjusting the Optional Settings Toadjustthesettings,followthesesteps: • • • • Withthethermostatturnedon PressPROG PressSETUP Usetheatthetopofthescreentoselectthe featurenumber(shownonpage23)andthenusethe keysinthecentreadjustthesetting. • PressDonetoacceptandStore 22 Feature Table Description Setting Feature 01 °C/°F TemperatureFormat 02 Switching Differential 01=1°C02=2°C3=3°C 1°C=Default 03 FrostProtect 00=Disabled01=Enabled (01=Default) 04 FrostTemp 05 OutputDelay Entervalue 00-15minutes(00=Default) 06 Comms# Enternumber01-32 07 TempLimit 00-10°C 10 OptimumStart 00=Disabled(Default) 01=01hr02=02hr03=03hr 11 RateofChange Forinformationonly 12 5/2Day 7Day 07-17°C(12=Default) 00Default 01 23 JGSTATPLUS/TS/V3 Model THE JGSTATPLUS/TS/V3 CONNECTED TO THE UH1 24 JGSTATPLUS/TS/V3 Model THE JGSTATPLUS/TS/V3 25 SupportTel:01254870303