Download Dell UPS 5600R Product Support Quick Notes
Transcript
PRO ODUCT SUPPORT QUIC CK NOTES –– DELL UPS MANAGEM MENT SOFTW WARE PSQ QN – Dell UPS Man nagemen nt Softwaare Con ntents: ‐ ‐ ‐ ‐ Scenaario 1: Single UPS, multiplee servers, USB or RS232 lo ocal connectio on Scenaario 2: Single UPS, multiplee servers, Network Managgement Card connection Scenaario 3: Multip ple redundantt UPS, multiple servers witth redundantt power suppllies Messaaging and Em mail Alerts Assu umptions: Netw work: All servvers should bee connected tto the same LLAN. Firew walls: Provision should be taken to enssure that firew walls are not blocking com mmunication o of the Dell sofftware agents between n networked servers. The po orts required b by the softwaare and netwo ork card (if ap ppropriate) are as follow ws. UDP: 219 98, 2199, 2200 0, 161(NMC), 162(NMC), 3 3369(NMC), TTCP: 2099. Softw ware versionss: The user should be usin ng the very latest software e version befo ore continuing with this gu uide. For more e information n go to http:///support.us.d dell.com/supp port/downloaads/ or equivvalent countryy page, search h by Dell UPS Managementt Software. Operrating System ms: This guidee is written prrimarily for W Windows operrating system ms. For installation on otheer operating systemss please referr to full Dell U UPS Software Users Guide.. ument: Dell UPS Software PSQN_SW‐A0 02 www.DellUP PS.com March, 2010 Docu Page 1 PRO ODUCT SUPPORT QUIC CK NOTES –– DELL UPS MANAGEM MENT SOFTW WARE Scen nario 1: ‐ ‐ ‐ ‐ Server 1 iss powered byy a single UPSSand is connected by USB. Server 2, 3 and 4 are also powered by the UPS. Server 2, 3 and 4 moniitor Server 1’ss agent for no otification of events and sh hutdown. Network M Managementt card is not in nstalled. 1 3 2 4 1 3 2 4 1 3 2 4 1 3 2 4 Gb 1 Gb 2 Gb 3 Gb 4 Gb 1 Gb 2 Gb 3 Gb 4 Gb 1 Gb 2 Gb 3 Gb 4 S econdary S ervers e (S ervers 2, 3, 4) Connected to UP S through UP PS S oftware e Network A gent P rimary S erv er (S erver 1) Connected to UP U S by US B or RS R 232 Gb 1 Gb 2 Gb 3 Gb 4 5 2 0 VAC B A T T .E X T 6V 9 3A 0 10A LS1 Customer LAN LS2 R E P OUT R E P O IN ACN I P UT 2 3 0 V ~ 1 0 A2 5 0 VAC 16A 2 5 0 VAC Po ower Cords RS232 Cab le (not included witth UP S by default) US B Cable e (default , included d) Netwo rk S witch Connectivityy diagram for D Dell UPS with USB or RS232 connection to four Dell servvers. Pow wer cables are ffor illustrativee purposes onlyy. For best pra actice refer to Dell UPS Cabliing Guide, Con nnectivity: Conn nect the Dell U UPS to a server via either tthe USB cablee (supplied) o or DB‐9 RS232 2 cable (custo omer purch hase option). DB‐9 pin‐outt configuratio on, pin # (use), 2 Tx (out from UPS), 3 Rx (in to UPS), 5 ground, 1, 4, 6, 7, 8, 9 unused). other servers are “secondaary” The sserver to whicch you make this connectiion is called the “primary” server. All o serve ers and are asssumed to be e on the samee customer LA AN. ument: Dell UPS Software PSQN_SW‐A0 02 www.DellUP PS.com March, 2010 Docu Page 2 PRO ODUCT SUPPORT QUIC CK NOTES –– DELL UPS MANAGEM MENT SOFTW WARE Quicck Start Su ummary: Shutdown parameters managed from a priimary server,, all others ass secondary. PS Manageme ent software o on all the servvers. On the primary servver the UPS w will be discoveered by Install the Dell UP me in the netw work tree diaagram Auto Search. To cconfigure shutdown settings, first click on the primary server nam and tthen configurre required sh hutdown paraameters. Add secondary sservers in thee Shutdown C Conditions op ptions box by en ntering their IIP address. O On the second dary servers, cclick on the server you waant to configure in the netw work tree diagrram and then in the shutdown parametters configuraation, choosee “Remote Shutdown by Aggent”. Enter the IP addre ess of the primary server tto create a 2‐‐way link betw ween the softtware agents. The softwaare agent on tthe primary server will broadcast sshutdown com mmands to th he secondary servers in the event of a p power failuree. uide Detailed Instaallation Gu Softw ware Installattion for primary server: Install the Dell UP PS Manageme ent software o on the primary server. Geet the latest vversion of the software from support.dell.com :  Drrivers & Down nloads  Cho oose model   Choose R71 10 server or similar  Systtem Firmwaree  Dell CD ISSO Image Once e installation o of the softwaare is complette, add the UPS to the man nagement console: 1. 1 Act as adm ministrator (d default passw word is to leavve the cell em mpty, just presss OK). Note that if at any time using this software you ur options are e grayed out, use “Act as aadministratorr” to restore yyour credentiials. 2. 2 Choose Syystem  Auto o Search UPS (later version ns of the softtware will auttomatically se earch for conn nected UPSs). The software looks for UPSSs attached to th he primary server An nd then when it finds the UPS itt is shown in the e “LAN” tree diaagram under LAN N ‐> PC Name ‐>> Port Name (USSB/COM1 ) ‐> UP PS Name 3. 3 Click on th he green Dell UPS Icon to ssee the poweer metrics. ument: Dell UPS Software PSQN_SW‐A0 02 www.DellUP PS.com March, 2010 Docu Page 3 PRO ODUCT SUPPORT QUIC CK NOTES –– DELL UPS MANAGEM MENT SOFTW WARE 4. 4 To configu ure server shutdown settin ngs click on th he primary se erver ID in thee network treee diagram (SSLOUKWE in this exaample). 5. 5 Edit the sh hutdown parameters: Menu  UPS  Shutdown Paarameter. nsure the corrrect connection method (USB or RS232 2) is selected in the first m menu list. a. En b. Choose your sh hutdown setttings. Availab ble options: i. Allow battery to disscharge for: tthe software begins shutdown of serve ers after x min ns on battery. ii. Shut d down when reemaining batttery time is beelow: the softtware begins the shutdow wn of serverrs x mins befo ore the UPS battery runs out. Note you u should allow w ample time for serverrs to shut dow wn safely. ument: Dell UPS Software PSQN_SW‐A0 02 www.DellUP PS.com March, 2010 Docu Page 4 PRO ODUCT SUPPORT QUIC CK NOTES –– DELL UPS MANAGEM MENT SOFTW WARE iii. Begin shutdown immediately if b battery low: keep this opttion checked. Should the U UPS return n to service affter a power ffailure and haave low battery, a subsequ uent power faailure would leave the UP PS with little b battery power and requiree immediate sshutdown of sservers. To con nfigure the UP PS to restart w when a minim mum charge h has been gain ned, refer to LLoad Segmeent Control. iv. System m: Shutdown//Suspend. Ch hoose Shutdo own unless yo ou have a Win ndows system m which you wo ould like to su uspend (hibernate) instead of shut dow wn. v. Time n needed for sysstem shutdow wn: this is thee approximatte time requirred for the seerver to complete the shutd down processs. The softwaare uses this ttime to calculate a safe duration n the server w will be safely sshut down beefore from rrequesting a ssystem shutdown to when powerring off the UPS output power sockets. vi. Remotte shutdown b by agent: when running th his software o on secondary servers check this box and ch hoose “Add”. Enter the IP P address of the primary seerver. The prrimary server will serverr as the contro oller while the secondary server will function as a grroup memberr. vii. Run co ommand file b before shutdo own: optionaal batch file or exe file proccessing beforre system shutdo own commen nces. viii. Shutdo own condition ns: add each secondary se erver IP addreesses to this list: Add  IP P address of servver. This tellss the UPS agent where to b broadcast shu utdown and ccontrol messaages. NOTE: Configurationss made in this m menu are “OR” co ommands, mean ning that whicheever event happeens first will cau use an action. If timings are in con nflict (e.g. shutdo own 20mins afteer power failure,, but shutdown immediately wh hen battery low ((and battery IS low), the software will begin a shuttdown immediattely. This is designed so that a sserver doesn’t w wait for 20minute es to shut down even though there is no batteryy power remaining. Instaalling the softtware on the secondary se ervers: Instaall the Dell UP PS Managemeent Software on all second dary servers. UPS Auto Seaarch will fail tto find a direcctly attacched Dell UPSS – this is norm mal. he secondaryy server ID in the network tree 1. 1 To configu ure server shutdown settin ngs click on th diagram (SLOUKWE in this example e). 2. 2 Access UP PS Shutdown Parameters: Menu  UPS  Shutdow wn Parameterr. 3. 3 Choose “rremote shutd down by agen nt”  Add  Enter IP addrress of primarry server. General shutdown n parameters do not need to be configu ured here (the ey are already configured on the primary se erver). The only variables to configure here are: a. Check the “Sysstem” box to request systeem shutdown n in the eventt of power failure. Optionss for W Windows platf forms are shu utdown or susspend (hibern nate). b. EEnter the “Tim me needed for system shuttdown” which h is the time required for tthe secondary server to o perform its shutdown prrocess. Be generous with tthis setting (ee.g Time+3 minutes). ument: Dell UPS Software PSQN_SW‐A0 02 www.DellUP PS.com March, 2010 Docu Page 5 PRO ODUCT SUPPORT QUIC CK NOTES –– DELL UPS MANAGEM MENT SOFTW WARE Linking the Agentts: In order to create a secure linkk between both primary an nd secondaryy server softw ware Agents: Prima ary Server: Add tthe secondarry server agen nt information n in the Shutd down Conditiions box: Meenu  Shutdo own Parameteer  Shutd down Conditiions  Add. Enter the IP aaddress(es) o of the secondaary servers ru unning the Deell UPS Managgement Softw ware. Secon ndary Server:: Menu  Shutdow wn Parameterr  Shutdown n Conditions : Check the ““System” boxx, then “Remo ote Shutown b by Agen nt”. Then “Ad dd” to enter the IP addresss of the primaary server (19 92.168.1.35 in n this example). Yourr installation iis complete. To test the ssystem, remove the input p power from tthe Dell UPS and wait unttil the pre‐cconfigured tim me options ellapse. Confirrm systems sh hutdown visu ually and thro ough event lo ogs. Note thiis will causee a shutdown n of servers a and so should d only be carrried out when n the servers are not in livve service! ument: Dell UPS Software PSQN_SW‐A0 02 www.DellUP PS.com March, 2010 Docu Page 6 PRO ODUCT SUPPORT QUIC CK NOTES –– DELL UPS MANAGEM MENT SOFTW WARE Sce enario 2 ‐ ‐ ‐ ‐ Server 1 iss powered byy a single UPSS. Server 2, 3 and 4 are also powered by the same UPS. Server 2, 3 and 4 moniitor the UPS ffor notificatio on of events aand shutdown n. Network M Managementt card is installed. 1 3 2 4 1 3 2 4 Gb 1 Gb 2 Gb 3 Gb 4 A ll s erv ers c ommunicate o with Dell D UP S throu ugh cus tomer LA N 1 3 2 4 1 3 2 4 Gb 1 Gb 2 Gb 3 Gb 4 Gb 1 Gb 2 Gb 3 Gb 4 Gb 1 Gb 2 Gb 3 Gb 4 5 2 0 VAC B A T T .E X T 9V 6 3A 0 10A LS1 R E P O IN P ow wer Cords 1 0 0 M MA C : ET HER NET A C IN P U T 2 3 0 V ~ CT A S te n g i s Customer LAN LS2 R E P OUT 1 0 A2 5 0 VAC 16A 2 5 0 VAC Dell UP S w ith optional H 910P P Network Management Card t (NMC ) ins ta lled. Connec ted to t LA N. cus tomer Networ k S witch 1 Conneectivity diagra am for Dell UPSS with optiona al Network Ma anagement Carrd and four D Dell Servers. Pow wer cables are ffor illustrativee purposes onlyy. For best pra actice refer to Dell UPS Cabliing Guide. Con nnectivity: Conn nect the Dell U UPS Network Managemen nt Card (NMC) to the custo omer networkk through a sttandard Ethernet cablee. The NMC sships with SNMP disabled by default, so o this must bee enabled thrrough the acccess control m menu beforre proceedingg. All other servers should d be connecteed to the sam me LAN. The LLAN must sup pport SNMP vv1 (early 1 Dell part number ffor NMC Card H910P varies b by region. ument: Dell UPS Software PSQN_SW‐A0 02 www.DellUP PS.com March, 2010 Docu Page 7 PRO ODUCT SUPPORT QUIC CK NOTES –– DELL UPS MANAGEM MENT SOFTW WARE card revisions) or v2 (later card d revisions) – so enable thee SNMP serviices on the seerver(s) and set the community stringg (public is de efault on netw work card). Quicck Start Su ummary: All se ervers communicate direcctly with the Dell UPS Network Managgement Card. Enterr the NMC settings througgh a web brow wser (http://[[IP ADDRESS])). The default username aand password d is ‘adm min’, ‘admin’. SNMP functionality of thee NMC is disabled by defau ult, so enablee this in the Access Controll menu. Configure the shu utdown param meters directly on the NMC C. The NMC is read‐only sso changes caan only be maade throu ugh this web interface. Install the Dell UP PS Manageme ent Software o on all serverss. Add the UP PS to the softw ware through h Menu  SN NMP  Searcch Device. Input the IP address of the N NMC. The Deell UPS will bee added in thee SNMP tree menu. Click o on the Dell U UPS to see paarameters. Fo or each serveer (click on current server iin network tree view first) set the follow wing param meters in thee Shutdown Parameters menu: Select thee correct inpu ut from the drrop down boxx (SNMP, and ensure IP ad ddress is correect) Check the e “system” bo ox to enable ssystem shutdo own Enter “Tim me needed fo or system shutdown” Whe en power failu ure occurs, th he NMC will send SNMP siggnals to the D Dell UPS softw ware in accordance with th he param meters configgured on the NMC and thee appropriatee course of action will be taaken. ‐ ‐ ‐ Detailed Instaallation Gu uide Configuring the N Network Management Carrd Referr to the quickk start guide p provided with h the NMC in order to provvide IP addresss and other network settings. The card is DHCP enab bled by defau ult so you should change th his to a static IP address on nce you have access the confiigurations pagge. 1. 1 Access the e NMC contro ol menu through a web brrowser. Inputt the address of http:// folllowed by thee IP address o of the NMC an nd use the default passwords of Usernaame: admin, P Password: admin. ument: Dell UPS Software PSQN_SW‐A0 02 www.DellUP PS.com March, 2010 Docu Page 8 PRO ODUCT SUPPORT QUIC CK NOTES –– DELL UPS MANAGEM MENT SOFTW WARE 2. 2 Enable SN NMP through the Menu  Access Contrrol  SNMP. You will be p prompted to restart the NMC for changes to take effect. To do this, cclick the hypeerlink at the ttop of the pagge, or visit Meenu  System m  Reset Com mmunication.. Note that th he “Reset Com mmunication n” button is close to the “Factory Reset”” button. 3. 3 Edit the sh hutdown parameters that you want to take effect in n the event off a power faillure: Menu   Shutdown n Parameters. Click on “Sh how advanced d Parameterss” to show all shutdown seettings. 4. 4 Refer to the NMC man nual for full information on n the control parameters, b but follows a summary of key points: a. In nverter: referss to the overaall UPS contro ols. b. Lo oad Segmentss 1 & 2: referr to the differeent banks of sockets on th he rear of the UPS which caan be co ontrolled indeependently o of each other (for example to shut down n non essentiial systems eaarly and saave battery fo or essential syystems, or to start some se ervers beforee others when n power returrns). i. Shutdo own if remain ning time und der: send shuttdown command when baattery has x seeconds remain ning. ii. Shutdo own if capacity under: as aabove, but expressed as a percent of baattery power.. iii. After xx min: initiatee the shutdow wn process aftter x secondss on battery. iv. Shutdo own duration n: time requirred for serverrs to safely sh hutdown befo ore UPS turns the outputt sockets off. v. Restarrt if capacity eexceeds: forcees the UPS to o wait until baatteries achieve x% chargee level beforee applying pow wer to the ou utput sockets and allowingg servers to reestart. NOTE: Configurationss made in this m menu are “OR” co ommands, mean ning that whicheever event happeens first will cau use an action. If timings are in con nflict (e.g. shutdo own 20mins afteer power failure,, but shutdown immediately wh hen battery low ((and battery IS low)), the softwaare will begin a shutdown imm mediately. This is designed so th hat a server doeesn’t wait for 20m minutes to shut down even though there is no b battery powerr remaining. ument: Dell UPS Software PSQN_SW‐A0 02 www.DellUP PS.com March, 2010 Docu Page 9 PRO ODUCT SUPPORT QUIC CK NOTES –– DELL UPS MANAGEM MENT SOFTW WARE Shu utdown parameter windo ow of Networrk Managemeent Card Softw ware Installattion: Install the Dell UP PS Manageme ent software o on all serverss. Get the late est version off the software e from support.dell.com :  Drrivers & Down nloads  Cho oose model   Choose R71 10 server or similar  Systtem Firmwaree  Dell CD ISSO Image Once e installation o of the softwaare is complette, add the UPS to the man nagement console: 1. 1 Click on th he SNMP treee item, then A Act as administrator (defau ult password is to leave th he cell empty,, just press OK). Note that iff at any time using this sofftware your o options are grrayed out, usee “Act as administrator” to resto ore your cred dentials. 2. 2 Add the U UPS to the sofftware: Menu u  SNMP   Search Devicce. Enter thee IP address o of the NMC. 3. 3 Click on th he Dell UPS under the SNM MP tree menu u to see the U UPS parameteers. ument: Dell UPS Software PSQN_SW‐A0 02 www.DellUP PS.com March, 2010 Docu Page 10 PRO ODUCT SUPPORT QUIC CK NOTES –– DELL UPS MANAGEM MENT SOFTW WARE 4. 4 To configu ure the shutd down settingss, first click on n the server yyou are configguring in the n network tree diagram (SLOUKW WE in this exam mple), then: M Menu  UPSS  Shutdown n parameterss. Choose SNM MP from the drop down boxx and confirm m this is the co orrect IP addrress in the nexxt box. The ssettings on the NMC prevaail over the default values in th he software so the only ch hanges require ed are: a. Seelect the corrrect input from the drop down box (SNMP, and ensu ure IP addresss is correct) b. Check the “sysstem” box to enable system m shutdown c. En nter “Time neeeded for sysstem shutdow wn” 5. 5 Repeat th he above step ps for each server. ument: Dell UPS Software PSQN_SW‐A0 02 www.DellUP PS.com March, 2010 Docu Page 11 PRO ODUCT SUPPORT QUIC CK NOTES –– DELL UPS MANAGEM MENT SOFTW WARE Masss configuratio ons: Latesst versions of the Dell UPS Managemen nt software su upports silentt installation aand mass con nfiguration pu ush across the n network. Thiss removes thee need to insttall the client and create settings manu ually on each sserver. Referr to the speciific documenttation of thesse features fo or full supportt. power from tthe Dell UPS and wait unttil the Yourr installation iis complete. To test the ssystem, remove the input p pre‐cconfigured tim me options ellapse. Confirrm systems sh hutdown visu ually and thro ough event lo ogs. Note thiis will causee a shutdown n of servers a and so should d only be carrried out when n the servers are not in livve service! ument: Dell UPS Software PSQN_SW‐A0 02 www.DellUP PS.com March, 2010 Docu Page 12 PRO ODUCT SUPPORT QUIC CK NOTES –– DELL UPS MANAGEM MENT SOFTW WARE Sce enario 3 Server 1 iss powered byy UPS 1 and U UPS 2. Server is connected by USB to UP PS 1. Server 2 iss powered byy UPS 1 and U UPS2. Server is connected by USB to UP PS 2. Server 3 cconnects to U UPS 1, Server 4 4 is connecteed to UPS 2. S erver 1 S erver 2 Serv er 3 Serv er 4 ‐ ‐ ‐ 1 3 2 4 1 3 2 4 1 3 2 4 1 3 2 4 Gb 1 Gb 2 Gb 3 Gb 4 Gb 1 Gb 2 Gb 3 Gb 4 Gb 1 Gb 2 Gb 3 Gb 4 Gb 1 Gb 2 Gb 3 Gb 4 S ec ondary S erv ers e Con nec ted to UP S throug gh UP S S oftware Network A gent g P rimary S erv ers e Con nnec ted direc tly to UP P S by US B LS2 R E P OUT UP S 1 LS1 ACN I P UT 2 3 0 V ~ 1 0 A2 5 0 VAC 16A R E P OUT 2 5 0 VAC LS2 LS1 UPS 2 5 2 0 VAC B A T T .E X T 6V 9 3A 0 10A Customer LAN 5 2 0 VAC BATTE . XT 6V 9 3A 0 10A R E P O IN R E P O IN ACN I P UT 2 3 0 V ~ P ower Cords UP S 1 P ower Cords UP S 2 1 0 A2 5 0 VAC 16A 2 5 0 VAC US S B Cable (default , inc c luded) Network S witc w h Connectiviity diagram fo or redundant D Dell UPS config guration and fo our Dell Serverrs. Pow wer cables are ffor illustrativee purposes onlyy. For best pra actice refer to Dell UPS Cabliing Guide. Con nnectivity: Conn nect the Dell U UPS 1 to server 1 using thee supplied USSB cable. Con nnect the Delll UPS 2 to serrver 2 using th he supplied USB cablle. All serverss are connectted to the cusstomer LAN. Servers 1 and d 2 are powerred by both U UPS 1 & 2 and sso are conside ered to be running in “red dundant” conffiguration. Seerver 3 is pow wered by UPSS 1 only. Servver 4 is powe ered by UPS 2 2 only. Servers 3 & 4 are o operating in n non‐redundan nt power conffiguration. ument: Dell UPS Software PSQN_SW‐A0 02 www.DellUP PS.com March, 2010 Docu Page 13 PRO ODUCT SUPPORT QUIC CK NOTES –– DELL UPS MANAGEM MENT SOFTW WARE Quicck Start Su ummary: Serve ers 1 & 2: Maanaging shuttdown condittions with a re edundant UP PS supply. Install the Dell UP PS Manageme ent software o on servers 1 aand 2. Configgure shutd down parameeters on the sservers in keeeping with insstallation notees for scenaario 1 for prim mary servers. Ensure that both UPS 1 aand UPS 2 are e visible on each of server 1 & & 2 through th he LAN or WA AN tree itemss. Now in thee shutdown meters for eaach software installation, cclick on the “R Redundant UPS” Input param Setting box and seelect both UP PS 1 and UPS 2 2 from the menu. The shu utdown settin ngs you applyy will now acccount for the status of botth UPS 1 and UPS 2. In neith her case do yo ou need to en nable “Remotte Shutdown by Agent” as each of Serve er 1 & 2 are d directly conneected to a UPSS. Serve ers 3 & 4: Maanaging shuttdown condittions from a rremote UPS. Install the Dell UP PS Manageme ent software o on servers 3 & & 4. Configurre shutdown parameters o on the servers in when choosing “Shutdown by keeping with instaallation notess for scenario 1 on secondaary servers. EEnsure that w remo ote agent” op ption that the correct Agen nt is selected to ensure thee correct messsaging (i.e. U UPS 1 to serveer 3 and UPS 2 2 to server 4)). Me essaging & & Email A Alerts To prrovide messaging to servers of your cho oice, access the broadcastt settings (Too ols  Broadcast Settings). Add all seervers’ IP addresses that yo ou want to brroadcast messsages to an nd then selectt which eventts you would like to broadcast. Note th hat the more events you select,, the more messages will b be sent. This service uses Microsoft Messsaging Servicee so ensure th hat you start this service to use the bro oadcast feature. To prrovide email aalerts on pow wer events, acccess the configuration me enu: Tools  Email Settings and provide the relevaant SMTP info ormation. Ad dd the recipie ent(s) email addre ess(es) and seelect which eevents to send d via email. FFor more detaailed explanattion of em mail settings rrefer to the D Dell UPS Softw ware Users Gu uide. ument: Dell UPS Software PSQN_SW‐A0 02 www.DellUP PS.com March, 2010 Docu Page 14