321-56849-21E Oct. 2008 SHIMADZU ELECTRONIC BALANCE ELB SERIES ELB120, ELB200, ELB300, ELB600, ELB1200, ELB2000, ELB3000, ELB12K, ELB600S, ELB6000S INSTRUCTION MANUAL MO DE 4500-10800-15ATD (374) UN IT TAR E ON/O FF BR EA K SHIMADZU ELECTRONIC BALANCE ELB SERIES ELB120, ELB200, ELB300, ELB600, ELB1200, ELB2000, ELB3000, ELB12K, ELB600S, ELB6000S INSTRUCTION MANUAL Read this manual thoroughly to ensure correct use of the equipment. Save this for reference in use. Safety Precautions NOTICE Precautions in this instruction manual are defined as follows. CAUTION! Failing to observe this may result in light to medium levels of injury or physical damage. NOTICE Information for the correct use of the equipment. Follow the cautions below for safe and proper use of the ELB balance. CAUTION! Do not use the ELB balance in dangerous areas*. Use only the AC adapter provided by the distributor authorized by Shimadzu if using an AC adapter. Use options and peripherals provided by Shimadzu. Use of inadequate attachments and peripherals may cause malfunction of the balance. The ELB balance is a precision instrument. Take enough care and precautions when handling it to ensure proper operation over a long period of time. * Places exposed to flammable gases, liquids or dust. Introduction Thank you for purchasing the Shimadzu ELB Series Electronic Balance. Before using the balance, read this Instruction Manual carefully and store it for reference in use. Declaration Of Conformity Shimadzu Corporation declares that the following products: ELB Series Electronic Balance conform to the following directives. Directives EMC directive 89/336/EEC amended by 92/31/EEC, 93/68/EEC EN55022: EN55024: 1994 /A1: 1995 /A2: 1997 (Class B) 1998 EN61000-3-2: 1995 /A1: 1998 /A2: 1998 EN61000-3-3: 1995 Low Voltage directive 73/23/EEC amended by 93/68/EEC EN60950: 1992 /A1: 1993 /A2: 1993 Weighing Instruments Department Analytical & Measuring Instruments Division SHIMADZU CORPORATION 1, Nishinokyo-Kuwabaracho Nakagyo-ku, Kyoto-shi 604-8511 JAPAN Contents 1. LIST OF COMPONENTS AND NAMES OF UNITS .......................................................................................1 2. FITTING & REPLACING THE DRY BATTERIES...........................................................................................4 3. INSTALLATION...............................................................................................................................................5 4. CAUTIONS AND NOTICES............................................................................................................................6 5. MEASUREMENT PROCEDURE....................................................................................................................6 6. AUTO POWER OFF FUNCTION ...................................................................................................................8 6.1 SETTING THE AUTO POWER OFF FUNCTION .............................................................................................8 6.2 DISABLING THE AUTO POWER OFF FUNCTION ..........................................................................................9 7. MENU SELECTION......................................................................................................................................10 8. REGISTRATION OF UNITS .........................................................................................................................12 8.1 CONDITIONS FOR REGISTRATION ............................................................................................................12 8.2 REGISTRATION PROCEDURES ..................................................................................................................12 8.3 DELETING THE REGISTRATION ................................................................................................................12 9. CALIBRATION ..............................................................................................................................................13 10. PIECE COUNTING.....................................................................................................................................14 11. PERCENTAGE CONVERSION ..................................................................................................................16 12. SPECIFIC GRAVITY MEASUREMENT .....................................................................................................17 13. SWITCHING UNITS ...................................................................................................................................19 14. PERFORMANCE INSPECTION.................................................................................................................20 15. MAINTENANCE..........................................................................................................................................21 16. MALFUNCTION?........................................................................................................................................22 17. SPECIFICATIONS ......................................................................................................................................23 18. PARTS LIST ...............................................................................................................................................25 19. SPECIAL ACCESSORIES (OPTIONS) ......................................................................................................26 19.1 BELOW-BALANCE-WEIGHING HOOK .....................................................................................................26 19.2 PERIPHERALS ........................................................................................................................................27 19.2.1 PRINTER EP-80..................................................................................................................................27 19.2.2 RS-232C INTERFACE IFB-102A ........................................................................................................27 19.2.3 INPUT/OUTPUT FORMAT ....................................................................................................................28 19.2.4 COMMAND CODES ..............................................................................................................................30 1. List of Components and Names of Units List of components The following components (one for each) are contained in the package. Balance main unit (Dry battery holder and dry battery cover are fitted before shipment.) In-use keypad protective cover Pan supporter Instruction manual Operating guide Pan (Dry batteries are not packed.) Names of units Small-pan model Large-pan model ① Balance main unit ② Dry battery cover ④ Pan supporter ⑤ Pan supporter shaft ⑥ Level indicator ⑦ Power jack ⑧ Level screws (3 places) ⑨ In-use keypad protective cover ⑩ Dry battery holder ⑪ DATA I/O connector 1 ③ Pan Key names and functons UNIT key ON/OFF(BREAK) key MODE key TARE key Name of Key Function ON/OFF(BREAK) 1) Turns the power on/ off. 2) Discontinues menu selection. 3) Cancels the Auto Print function. 4) Stops continuous data output to external instruments. TARE 1) Subtracts the weight of the container. 2) Confirms menu selections. 3) Sets the reference values for piece counting and percentage conversion. UNIT 1) Switches the units. 2) Cancels the Auto Print function. 3) Stops continuous data output to external instruments. MODE 1) Selects different menu items. 2) Measures the weight in air during specific gravity measurement. 3) Cancels the Auto Print function. 4) Stops continuous data output to external instruments. 2 Display Auto Print mark: Illuminates when the Auto Print function is turned on. Low Battery mark: Replace the dry batteries when this illuminates. Percentage mark Turn off the power immediately if this mark illuminates. Piece counting mark Negative sign mark Gram mark Stability mark: Illuminates when the display stabilizes. Specific gravity measurement mark Center Zero mark: Illuminates when the display stabilizes within 0 ±0.25 of the minimal increment. Not applicable depending on the local regulations for measuring instruments. 3 2. Fitting & Replacing the Dry Batteries Always use six AA dry batteries. NOTICE The dry batteries are fitted or replaced according to the steps outlined below. Fitting the dry batteries (1) Press down lightly on the part of the dry battery cover and pull it in the indicated direction to remove it. (2) Take out the dry battery holder. (3) Fit six AA batteries in the dry battery holder. When replacing the dry batteries, take the used dry batteries out of the holder. CAUTION! Make sure that the polarities are correct when fitting the batteries. CAUTION! Do not mix and use old dry batteries with new ones. (4) Put the dry battery holder back in place and fit the dry battery cover in the indicated direction. 4 3. Installation Power suppy NOTICE The dry batteries are not included. In addition, the unit will operate off the dry batteries if the AC adaptor is connected. Installation location Avoid the following conditions: CAUTION! Exposure to corrosive or flammable gases. NOTICE Exposure to dust, wind, vibrations, electromagnetic waves and magnetic fields. NOTICE Exposure to direct sunlight, remarkable temperature fluctuations. NOTICE Extremely high/low temperatures or high/low humidity. Installation (1) Remove the protection paper at 2 places on the in-use keypad protective cover and mount the cover over the keypad. (2) Mount the pan supporter and the pan on the pan supporter shaft. (3) Assure the horizontal installation of the balance by rotating the level screw until the air bubble in the level comes to a rest in the center of the red circle. (Also check that the balance is placed steadily.) For quick adjustment, screw in the back left level screw until it does not touch the table. Level the balance using the 2 screws at the rear. Finally, adjust the back left level screw so that it touches the table supporting the balance steadily. * Figures show small-pan model. 5 4. Cautions and Notices Observe the CAUTION! Use only the AC adaptor provided by the distributor authorized following: by Shimadzu if using an AC adaptor. NOTICE Make sure that any foreign objects, including water and metal pieces, do not enter the interior of the balance. NOTICE Do not leave the balance with objects on the pan. NOTICE Do not cause a shock to the pan. 5. Measurement Procedure The procedures are explained using the ELB300 as an example. Turn on the power (1) Check that nothing is placed on the pan. (2) Press the [ON/OFF(BREAK)] key. (3) The Check display will illuminate, indicating that the temperature sensor inside the balance is being checked. Depending on the ambient temperature, this may remain illuminating for about 30 seconds. (4) The all segments illuminate for approximately 6 seconds. (5) Zero is displayed. The zero may be unstable immediately after the power is turned on. Allow the balance to warm up for more than 5 minutes. To conduct accurate measurements, a warm up time of over 30 minutes is recommended. (6) Calibrate sensitivity (refer to “9. Calibration”). 6 Measurement (1) Place the container* on the center of the pan and press the [TARE] key. Check that the Center Zero mark illuminates. (2) Load the sample and read the displayed value when the display stabilizes. To conduct accurate measurements, perform a preliminary loading* before conducting measurements. “oL” will be displayed if the weight of the sample exceeds combined weight the of capacity, the or the sample and container exceeds the total available range of the balance. (3) Dry Batteries consumption can be reduced by activating the Auto Power Off function. Refer to “6. Auto Power Off Function” for information on how to set and disable the Auto Power Off function. *Container: Any container in which the sample is placed. Measurements without any container are also possible. *Preliminary “Preliminary loading” refers to loading and unloading the sample or the weight loading: once before conducting the actual measurement. A preliminary loading improves the accuracy of the measurement. Turn off the power Press the [ON/OFF(BREAK)] key during weight display. CAUTION! Be sure to turn off the power when the balance is not to be used for a long period of time. 7 6. Auto Power Off Function The power is automatically cut when the balance is left unused* for about 5 minutes or more. Effective usage of this function can reduce dry batteries consumption. *The balance is considered to be unused when the following conditions (1) and (2) continue. (1) Keys are not operated. (2) No changes in the measured weight value amounting to “approx. 1g or more over a 0.5 second period” are detected. NOTICE This function is activated at the time of factory shipment. 6.1 Setting the Auto Power Off Function (1) Press the [MODE] key 5 times from weight display. (2) The display shown on the right will appear. (3) Press the [TARE] key. (4) The balance will revert to weight display after the display on the right is shown. CAUTION! The internal values of the balance are being revised while “SEt” is displayed. Never turn off the power while “SEt” is displayed. (5) When the Power Off function is activated, the display will begin to flash approx. 10 seconds before the power is about to be cut. The display will stop flashing if either the keys are operated or an item of about 1g or more is weighed, in which case the balance will return to normal weighing mode. 8 6.2 Disabling the Auto Power Off function (1) Press the [MODE] key 6 times. (2) The display shown on the right will appear. (3) Press the [TARE] key. (4) After the display shown on the right appears, the balance will revert to weight display. CAUTION! The internal values of the balance are being revised while “SEt” is displayed. Never turn off the power while “SEt” is displayed. 9 7. Menu Selection Various functions, including selecting different measurement speeds and setting of the piece counting mode, are available on the ELB-series balance. Selection of these functions is referred to as “Menu Selection”. Procedure (1) Press the [MODE] key. (2) The currently set conditions are displayed in symbols. (Example) Auto Power Off function activated * Zero tracking activated * Stability detection width: Large Normal Response Mode (Items with “*” illuminates when set to on.) (3) The display changes in the order shown in the table on page 11 by pressing the [MODE] key. (4) To select a condition or a mode, press the [TARE] key while the condition or the mode is displayed. When a condition or a mode is selected, “SEt” is displayed, and then it reverts to the weight display. (This does not occur when calibration, piece counting, or percentage conversion is selected.) CAUTION! The internal values of the balance are being revised while “SEt” is displayed. Do not turn off the power while “SEt” is displayed. (5) After displaying “SG” (“Unit kg” for the ELB12K), the balance reverts to the weight display. - Press the [ON/OFF(BREAK)] key to stop menu selection. - Set the response mode to “Normal” (A-2) in ordinary cases. Set the response mode to “Fast” (A-1) when it is necessary to reduce the time required for measurements. (Be acknowledged that measurement accuracy may be sacrificed). 10 - Set the internal stability detection width to “Large” (P-2) when external causes such as vibration hinder smooth output for Auto Printing, or when intending to reduce the time required for output. (Be acknowledged that measurement accuracy may be sacrificed.) - Activating Zero Tracking (d-on) will automatically cancel the minor fluctuation in the zero display. Select “d-off” when measuring slight differences of the weight. Menu Items Display Mode Conditions Mode Units Description Symbol for conditions display Conv PCS Conv % CAL P.C.-on P.C.-oF A-1 A-2 P-1 P-2 d-on d-off IF Piece counting Percentage conversion Calibration Auto Power Off function activated Auto Power Off function disabled P Fast Response Mode Normal Response Mode Internal stability detection width: Small Internal stability detection width: Large Zero tracking: ON Zero tracking: OFF RS-232C communication specification settings 1 2 1 2 d SG *1 Unit kg Unit g Unit ct *2 Unit oz *2 Unit ozt *2 Unit dwt *2 Unit GN *2 UnitH tl *2 UnitS tl *2 Unitt tl *2 Unit mo *2 Unit W *2 Unit k *2 Unit *2 Unit Tct *2 Unitt Ttl *2 Unitt Wtl *2 Unitt WTtl CLEAr Specific gravity measurement Kilogram Gram Carat Ounce Troy ounce Penny weight Grain Hong Kong tael Singapore tael Taiwan tale (1) Momme Pound Kyats Sawaran Custom Taiwan tale (2) Taiwan tale (3) Taiwan tale (4) Canceling registered units *1ELB12K only *2Not applicable depending on the local regulations for measuring instruments. 11 1ct=0.2g 1oz=28.3495g 1ozt=31.1035g 1dwt=1.55517g 1GN=0.0647989g 1tl=37.429g 1tl=37.7994g 1tl=37.5g 1mo=3.75g 1Lb=453.6g 1Ks=16.6g 1S=7.999g 1custom=11.664g 1tl=37.5g 1tl=37.5g 1tl=37.5g 8. Registration of Units Three units can be registered in addition to “gram”. The registered units remain after the power has been turned off. Registered units can be selected by pressing the [UNIT] key. 8.1 Conditions for Registration - Up to three units (including piece counting, % and specific gravity) can be registered in addition to “gram”. - When a new unit is added after three units have been registered, the first-registered unit is deleted and the new unit is added. 8.2 Registration Procedures 1) Repeat pressing the [MODE] key while the balance displays the weight (except for the case of specific gravity measurement) until “Unit xx” is displayed. 2) Press the [TARE] key when the desired unit is displayed. “” is displayed for already registered units. 3) “SEt” appears on the display and it changes to the weight display with the newly registered unit. CAUTION! The internal values of the balance are being revised while “SEt” is displayed. Do not turn off the power while “SEt” is displayed. 8.3 Deleting the Registration - Follow the procedure below to delete registered units one by one. (Piece counting and % cannot be deleted by this method.) 1) Repeat pressing the [MODE] key while the balance displays the weight (except for the case of specific gravity measurement) until “Unit xx” is displayed. 2) Repeat pressing the [MODE] key until the unit to delete is displayed. “” is displayed for already registered units. 3) Press the [TARE] key when the unit to delete is displayed. 4) “SEt” appears on the display and it changes to the weight display. CAUTION! The internal values of the balance are being revised while “SEt” is displayed. Do not turn off the power while “SEt” is displayed. - Follow the procedure below to delete all the units registered. 1) Repeat pressing the [MODE] key while the balance displays the weight (except for the case of specific gravity measurement) until “CLEAr” is displayed. 2) Press the [TARE] key while “CLEAr” is displayed. 3) “SEt” appears on the display and it changes to the weight display. CAUTION! The internal values of the balance are being revised while “SEt” is displayed. Do not turn off the power while “SEt” is displayed. 12 9. Calibration The ELB-series electronic balance measures the weight using the gravity of the earth. Since the acceleration due to gravity varies slightly from region to region, the sensitivity must be calibrated when the balance is installed. Perform sensitivity calibration also in the following cases: (1) when there was a large fluctuation in room temperature, (2) before conducting measurements requiring a high degree of accuracy, (3) when moving the balance from one place to another, and (4) as periodical maintenance once a month. Procedure (1) With nothing on the pan, go through the menu selections to display “CAL” for calibration. (Refer to “7. Menu Selection”.) Press the [TARE] key. (2) The value of the weight to be used for calibration flashes on the display. (3) Place the calibration weight on the pan. (Refer to “17. Specifications” for information on the calibration weight.) (4) Press the [TARE] key when the stability mark illuminates. (5) Zero flashes on the display. (6) Remove the weight from the pan and press the [TARE] key when the stability mark is displayed. (7) “End” appears on the display and it reverts to the weight display. CAUTION! The internal values of the balance are being revised while “End” is displayed. Do not turn off the power while “End” is displayed. - “C E4” is displayed if an improper weight is placed on the pan, disenabling calibration. 13 - Press the [ON/OFF(BREAK)] key to abort calibration. “Abort” is displayed and then the balance reverts to the weight display. Aborting is not possible while “End” is being displayed. 10. Piece Counting The ELB-series balance is capable of counting the number of pieces of the sample by measuring the weight of a single piece of the sample. The number of pieces to determine the weight of the single piece can be selected from 10, 20, 50 and 100 (the larger the number of pieces, the higher the measurement accuracy). The counted number of pieces is displayed with the unit “PCS”. Setting procedure (1) Place the container on the pan and press the [TARE] key. (2) Select piece counting mode (Conv PCS) in menu selection, and press the [TARE] key. (Refer to “5. Menu Selection”.) (3) The number of reference pieces “10” is displayed. Select the intended number by pressing the [MODE] key. The displayed number changes in the following order: 10 -> 20-> 50 -> 100 -> 10… (4) Place the displayed number of sample pieces in the container while the number of reference pieces is displayed. (5) Press the [TARE] key when the stability mark illuminates. (6) After “SEt” is displayed, it changes to the piece counting display with the “PCS” mark illuminating. 14 At the same time, the reference weight and the “PCS” unit are registered on the [UNIT] key. (Refer to “13. Switching Units”). CAUTION! The internal values of the balance are being revised while “SEt” is displayed. Do not turn off the power while “SEt” is displayed. - If the sample weight exceeds the capacity of the balance, or the weight of a piece of the sample is smaller than the minimum increment, “r E4” is displayed and the display reverts to the unit before menu selection. - Press the [ON/OFF(BREAK)] key to abort piece counting settings. “Abort” is displayed and then it reverts to the display before menu selection. Aborting is not possible while “SEt” is being displayed. 15 11. Percentage Conversion The ELB-series balance is capable of calculating and displaying the sample percentage to the reference set as 100%. Setting procedure (1) Place the container on the pan and press the [TARE] key. (2) Select percentage conversion mode (Conv %) in menu selection, and press the [TARE] key. (Refer to “7. Menu Selection”.) (3) “100%” is displayed. (4) Place the sample to be used as reference in the container. (5) Press the [TARE] key when the stability mark illuminates. (6) After “SEt” is displayed, it changes to the percentage display with the “%” mark illuminating. At the same time, the reference weight and the “%” unit are registered on the [UNIT] key. (Refer to “13. Switching Units”) CAUTION! The internal values of the balance are being revised while “SEt” is displayed. Do not turn off the power while “SEt" is displayed. - If the sample weight exceeds the capacity of the balance, or it is smaller than 100 times the minimum increment, “r E4” is displayed and the display reverts to the unit before menu selection. - Press the [ON/OFF(BREAK)] key to 16 abort piece counting settings. “Abort” is displayed and then it reverts to the display before menu selection. Aborting is not possible while “SEt” is being displayed. - % will be displayed with the following number of digits depending on the weight of the reference sample. Less than 1000 times the minimum increment No decimals Less than 10000 times the minimum increment To the 1st decimal place More than 10000 times the minimum increment To the 2nd decimal place 12. Specific Gravity Measurement The ELB-series balance allows easy measurements of the specific gravity of a sample by measuring its weight in air and in water (with the specific gravity of water taken to be one). The optional below-balance-weighing hook facilitates the measurement in water. Described below is the procedure when using the below-balance-weighing hook. (See “19.1 Below-Balance-Weighing Hook”.) The optional “Specific Gravity Measurement Set” is also available. The weight in air during specific gravity measurement is displayed as grams. Procedure (1) Select specific gravity measurement mode (SG) in menu selection. (Refer to “7. Menu Selection”.) (2) Press the [TARE] key. “SEt” is displayed and then “g” and the specific gravity measurement mark (▼) illuminate. CAUTION! The internal values of the balance are being revised while “SEt" is displayed. Do not turn off the power while “SEt" is displayed. (3) Press the [TARE] key when there is no sample on the pan to zero the display. 17 (4) Place the sample on the pan to measure its weight in air. Sample Balance Base Water tank Underwater pan (5) Press the [MODE] key when the display has stabilized. (6) The gram mark disappears with the specific gravity measurement mark remaining illuminating and displaying the specific gravity value. (The display fluctuates. However, this is not a problem.) (7) Unload the sample and place the sample on the underwater pan. (8) Read the displayed value when the stability mark illuminates. - The weight in air has to be more than 100 times the minimum increment to ensure accurate measurements. (9) Press the [UNIT] key to revert to the gram display. - “-OL” is displayed if the calculation results are negative. - The calculation results can be output by the print command while the results are being displayed. (Continuous output is not possible during specific gravity measurement.) - Return to step (3) by pressing the [MODE] key to continue specific gravity measurements. - The specific gravity is calculated using the following equation. (Weight in Air) (Weight in Air) – (Weight in Water) - To stop specific gravity measurement and revert to weight measurement… 18 (a) while displaying specific gravity value: press the [MODE] key and then press the [UNIT] key. (b) while displaying weight in specific gravity mode (while displaying “▼ g”): press the [UNIT] key. - The specific gravity measurement is registered for the [UNIT] key. Specific gravity measurement can be started from step (3) by pressing the [UNIT] key during weight measurement. (10) To cancel specific gravity measurement, follow the procedure below. - Press the [UNIT] key to display another unit (g, PCS, or %). - Press the [MODE] key to display “SG”. - The stability mark illuminates if specific gravity measurement has been set. - Press the [TARE] key. This cancels the specific gravity measurement, and the balance displays ordinary units such as g, PCS and %. 13. Switching Units - Pressing the [UNIT] key switches the unit between “g” and other registered units. (The balance may be shipped from the factory with no units registered. In this case, the unit cannot be switched.) - When piece counting or percentage conversion is registered for the [UNIT] key, the value will be calculated and displayed using the latest reference. - The registered units remain after the power is turned off. The unit registered most recently appears on the display when the power is turned on. - Three units can be registered in addition to grams. 19 14. Performance Inspection Conduct performance inspection in a room at a temperature of approximately 25°C without large fluctuation. Perform this inspection as a guide to judge the proper operation of the balance. - Warm up the balance for more than 30 minutes after turning on the power. Preparation - The inspection should be conducted with the gram display. If another unit is displayed, press the [UNIT] key to switch to the gram display. - Select the following conditions in menu selection. Response mode A-2 (Normal) Internal stability detection width P-1 or P-2 Zero tracking d-oFF (off) - Perform preliminarily loading, and then press the [TARE] key to zero the display. Repeatability (1) Repeat loading and unloading a weight close to the capacity 10 times and record the following values. Xi: the value at which the display stabilizes after loading Yi: the value at which the display stabilizes after unloading (2) Obtain the standard deviation σx and σy using the equation below. 10 σx = ∑ ( Xi − Xi) i =1 9 10 σy = 2 ∑ (Yi − Yi) 2 i =1 9 (3) Both σx and σy should be within 1.5 times the standard deviation indicated in “17. Specifications”. Cornerload error (1) Load a weight of approximately 1/4th the weighing capacity in the order of the numbers in the diagram below and record the values X1 to X5. (2) The differences between the value at the center of the pan (X1) and other values (X2 to X5) should be within 3 times the minimum increment. 20 In the case of a square pan 4 3 1 2 5 In the case of a round pan 3 4 1 5 2 15. Maintenance NOTICE Wipe any dirt away with a soft cloth moistened with a neutral detergent. NOTICE Organic solvents and chemical dusters will damage the coating and membrane panel. NOTICE Use the protective cover (supplied as a standard accessory or as an optional accessory) when using the balance in places where dirt may attach. NOTICE The pan can be washed in water. Be sure that it is completely dry when using. 21 16. Malfunction? Check the following items before contacting our service personnel. When? Phenomenon Before - Nothing is displayed measurement after the power is turned on. - Stops at “CHE t”. Cause and Solution -Dry batteries have not been fitted. -Dry batteries are drained. See “2. Fitting & Replacing the Dry Battery” and either fit the dry batteries or replace with new ones. - Depending on the ambient temperature, “CHE t” may be displayed for about 1 minute. If “CHE t” remains displayed for more than 1 minute, contact our service personnel. During - “OL” is displayed. measurement - An object heavier than the capacity has been placed on the pan. - Sensitivity (span) is not correct. See “9. Calibration”. - “-OL” is displayed. - The display fluctuates. - The pan and/or pan supporter is not mounted correctly. - Affection of vibration or wind. Install the balance at a place without vibration or wind. Set the response speed to normal. - Affection of electromagnetic waves or electrical noise. Place the balance away from the noise source. - The Low Battery mark -Dry batteries are empty. See “2. Fitting & Replacing the Dry Battery”. remains illuminated. - The display goes off. -Dry batteries have not been fitted. -Dry batteries are drained. See “2. Fitting & Replacing the Dry Battery” and either fit the dry batteries or replace with new ones. -The Auto Power Off function was activated. See “6. Auto Power Off Function”. During piece - Number of pieces cannot - There is a large variation in the weight between pieces of counting be counted correctly. the sample. Increase the number of the reference sample pieces. During specific - The specific gravity gravity value fluctuates. - The weight of the sample is too small for the specific gravity. measurement 22 If the following codes display during operation, solve the problem by applying the solution below. Code C E4 Description Solution This appears when an Restart calibration with the correct weight. improper weight is placed on the pan during calibration. C E2 This appears when trying to Restart calibration after removing the object from the start calibration with an object pan. on the pan. r E4 This appears when the Reset the reference with a larger amount of sample. reference value is smaller than the minimum increment in piece counting or percentage conversion mode. Internal temperature sensor Stop using the balance and contact our service Err 1 personnel. error. Err 4 Internal computation error. 17. Specifications Model ELB120 ELB200 ELB300 ELB600 Weighing capacity Minimum display Standard deviation Linearity errors Calibration weight Pan size (mm) Stability of Sensitivity ( 5 to 35°C ) Dimensions of main body (mm) Weight (kg) Temperature range 120g 0.01g σ≤0.01g ±0.01g 100g 200g 0.01g σ≤0.01g ±0.01g 200g φ110 300g 0.01g σ≤0.01g ±0.02g 300g 600g 1200g 0.05g 0.1g σ≤0.05g σ≤0.1g ±0.05g ±0.1g 500g 1000g 170x130 ±20ppm/°C ±15ppm/°C ±10ppm/°C Power supply Continuous operation time AC adapter (Option) ±20ppm/°C Approx. 185(W) x 215(D) x 55(H) Approx. 1.25 5 to 40°C 6 x AA dry batteries 9DCV (1.5DCV x 6) Approx. 40 hours (using alkaline dry batteries) DC output voltage: 9 DCV DC output current: 80mA Shape of the plug: 23 ELB1200 ±20ppm/°C Model ELB2000 ELB3000 ELB12K ELB600S ELB6000S Weighing capacity Minimum display Standard deviation Linearity errors Calibration weight Pan size (mm) Stability of Sensitivity ( 5 to 35°C ) Dimensions of main body (mm) Weight (kg) Temperature range 2000g 0.1g σ≤0.1g ±0.1g 2000g 3000g 0.1g σ≤0.1g ±0.2g 3000g 12kg 1g σ≤1g ±1g 10kg 170 x 130 600g 0.1g σ≤0.1g ±0.1g 500g 6000g 1g σ≤1g ±1g 5000g ±15ppm/°C ±10ppm/°C ±20ppm/°C ±20ppm/°C ±20ppm/°C Power Continuous operation time AC adapter (Option) Approx. 185(W) x 215(D) x 55(H) Approx. 1.25 5 to 40°C 6 x AA dry batteries 9DCV (1.5DCV x 6) Approx. 40 hours (using alkaline dry batteries) DC output voltage: 9 DCV DC output current: 80mA Shape of the plug: 24 18. Parts List Special Accessories (Options) Product Name P/N Remarks Below-weigh hook 321-34532-03 Cannot be used with the ELB12K. Specific gravity measurement kit 321-42253 Use with a balance whose capacity is 600g or SMK-201 more (the measurable weight is reduced by 200g). This set allows specific gravity measurement of samples with a volume of 5 to 500cm3 (the size of the sample must be smaller than 115mm in diameter x 70mm in height). Calibration weight 100g 321-53445-10 200g 321-53446-10 500g 321-53447-10 1kg 321-53448-10 2kg 321-53449-10 5kg 321-53450-10 10kg 321-53451-10 Electronic Printer, EP-80 321-62675-01 RS-232C interface, IFB-102A 321-41167-10 Carrying case 321-50136 Impact dot, Normal paper Maintenance Parts Item P/N Remarks Square pan 321-41419 For large-pan model Pan supporter, square 321-41394-90 For large-pan model Round pan 321-41418-10 For small-pan model Pan supporter, round 321-40910-90 For small-pan model In-use protective cover 321-41617-01 1 piece 321-41617-70 Contains 10 pieces In-use keypad protective cover 321-62243 1 piece Level adjusting feet 321-53530-30 Rubber feet 321-33634-02 Dry battery cover 321-62247-51 Dry battery holder 321-61994-02 25 19. Special Accessories (Options) 19.1 Below-Balance-Weighing Hook With the below-balance-weighing hook, the sample can be suspended below the balance for weighing. This is particularly useful for specific gravity measurements. Attaching the hook to the balance (1) Turn off the power. (2) Remove the pan and pan supporter. (3) Remove the seal on the back of the balance. (4) CAUTION! While holding down the pan supporter shaft, screw the hook into the screw hole on the bottom of the balance by hand. (Do not use any tools such as a monkey wrench to tighten the hook, as it may damage the sensor inside the balance.) (5) Place the balance at a place where no excess force is applied to the hook. (6) Remount the pan supporter and pan onto the pan supporter shaft. Below-balance-weighing hook 26 19.2 Peripherals 19.2.1 Printer EP-80 The EP-80 is a printer connected to the DATA I/O connector of the balance. The EP-80 prints the data displayed on the balance and performs statistical calculations. See the instruction manual for the EP-80 for detailed information. Before using the EP-80, set the baud rate to 1200bps and stop bit to 1. (See “Selecting the Baud Rate” and “Selecting the Stop Bit” on page 29.) 19.2.2 RS-232C Interface IFB-102A The IFB-102A is used to connect the balance to external devices such as a personal computer. Connection After confirming that the power of the balance has been turned off, insert the plug of the IFB-102A into the DATA I/O connector of the balance. Signals Pin No. Signal Name I/O 1 FG 2 TXD Out 3 RXD In 4 RTS 5 CTS 6 DSR 7 SG 20 DTR Description Ground Data output Data input Short circuit In Out 27 Communication possible with polarity (+) Communication impossible with polarity (-) 19.2.3 Input/Output Format Key: “∆” indicates a space and (CR) indicates a carriage return. Input data Output data Command code + (CR) -> See “19.2.4 Command Codes”. - When displaying the weight S - ∆∆ 300.00 g∆ (CR) Unit + space Space, number, decimal point Polarity Positive space (∆) Negative minus (-) Internal stability (when outputting with stability information) Stable S Unstable U - When “oL” or “-OL” is displayed S - ∆∆∆∆ oL ∆∆∆∆ (CR) Unit + space Polarity Positive space (∆) Negative minus (-) Internal stability (when outputting with stability information) Data format Stable S Unstable U - ASCII (JIS) code - Baud rate Select from 300, 600, 1200, 2400, 4800, and 9600. - Parity Select from “EvEn” (even number), “odd” (odd number), and “non” (none). - Data length - Stop bit Without parity 8 bit With parity 7 bit Select from 1 and 2. NOTICE Set the baud rate to 1200 and the stop bit to 1 when using the EP-80. 28 Selecting the baud rate (1) Press the [MODE] key to display “iF” (see “5. Menu Selection”). (2) Press the [TARE] key to display “bPS”. (3) Press the [TARE] key. (4) “300” is displayed. The display changes in the following order by pressing the [MODE] key: 300 -> 600 -> 1200 -> 2400 -> 4800 -> 9600 -> 300… The currently selected baud rate is displayed with the stability mark. (5) Select the desired baud rate and press the [TARE] key. Selecting the (1) Press the [MODE] key to display “iF”. parity (2) Press the [TARE] key to display “bPS”. (3) Press the [MODE] key to display “Prty”. (4) Press the [TARE] key to display “EvEn”. (5) The display changes in the following order by pressing the [MODE] key: EvEn -> odd -> non -> EvEn… The currently selected parity is displayed with the stability mark. (6) Select the desired parity and press the [TARE] key. * The data length becomes 7 bits if “EvEn” or “odd” is selected for the parity. Selecting the (1) Press the [MODE] key to display “iF”. stop bit (2) Press the [TARE] key to display “bPS”. (3) Press the [MODE] key to display “StoP”. 29 (4) Press the [TARE] key to display “1”. (5) The display changes in the following order by pressing the [MODE] key: 1 -> 2 -> 1… The currently selected stop bit is displayed with the stability mark. (6) Select the desired stop bit and press the [TARE] key. 19.2.4 Command Codes Shown below are commands available when the balance is connected to external devices such as a personal computer. See “19.2.3 Input/Output Format” for information on data formats. Inputting characters or control codes that are not listed below may impede the proper operation of the balance or the performance of correct measurements. When connecting the balance to external devices to conduct unattended operation, take appropriate precautionary measures against unexpected communication failure (setting a waiting time for input, for example). Command code T D05 Function Subtraction of the Description Zeros the display. container weight Print (once) Outputs the displayed data. Outputs the displayed data automatically when the display D06 Auto Print * stabilizes after an object is placed on the pan while zero is displayed. Outputs the displayed data continuously at an interval of D01 Continuous output * D09 Output stop Stops Auto Print and continuous output. Single output with Outputs the data once with the internal stability information. D07 D03 approx. 100ms. stability information Continuous output Outputs the data continuously with the internal stability with stability information. information * Commands with “*” are cancelled by pressing the [ON/OFF(BREAK)], [UNIT], or [MODE] key. 30 321-56849-21D M054-E119D May 2008 SHIMADZU ELECTRONIC BALANCE ELB SERIES ELB120, ELB200, ELB300, ELB600, ELB1200, ELB2000, ELB3000, ELB12K, ELB600S, ELB6000S INSTRUCTION MANUAL MO DE 4500-06800-400TD (374) UN IT TAR E ON/O FF BR EA K Operating Guide [Menu Selection] 321-56849-21E Oct. 2008 ELB Series (1) Press the [MODE] key. The currently selected conditions are displayed in symbols. (2) The display changes in the order shown in the table at right each time the [MODE] key is pressed. Press the [TARE] key when the item to set is displayed. (3) “SEt” is displayed and it reverts to the weight display. CAUTION! The internal values of the balance are being revised while “SEt” is displayed. Do not turn off the power while “SEt” is displayed. CAUTION! Menu selection is not possible in the specific gravity measurement mode. Display a different unit by pressing the [UNIT] key to start menu selection. [Registering and Deleting Units] Registration (1) Press the [TARE] key when the desired unit is Display Description Conv PCS Piece counting Conv % Percentage conversion CAL Calibration P.C.-on Auto Power Off function activated P.C.-oF Auto Power Off function disabled A-1 Fast Response Mode A-2 Normal Response Mode P-1 Internal stability detection width: Small P-2 Internal stability detection width: Large d-on Zero tracking: ON d-off Zero tracking: OFF IF RS-232C communication specification settings SG Specific gravity measurement 1 * Unit kg Kilogram Unit g Gram Unit ct Carat 2 * Unit oz Ounce 2 * Unit ozt Troy ounce 2 * Unit dwt Penny weight 2 * Unit GN Grain 2 * UnitH tl Hong Kong tael 2 * UnitS tl Singapore tael 2 * Unitt tl Taiwan tale (1) 2 * Unit mo Momme 2 * Unit W Pound 2 * Unit k Kyats 2 * Unit Sawaran 2 * Unit Tct Custom 2 * Unitt Ttl Taiwan tale (2) 2 * Unitt W tl Taiwan tale (3) 2 * Unitt WTtl Taiwan tale (4) CLEAr Canceling registered units 1 * ELB12K only 2 * Not applicable depending on the local regulations for measuring instruments. displayed. Already registered units are displayed with the “o” mark. (2) “SEt” is displayed and then it changes to the weight display in the registered unit. Deletion (1) Press the [TARE] key when the unit to delete is displayed. Already registered units are displayed with the “o” mark. (2) “SEt” is displayed and then it changes to the weight display. Delete All (1) Select “CLEAr” and press the [TARE] key. (2) “SEt” is displayed and then it changes to the weight display in grams. [Sensitivity Calibration] (1) Select “CAL” (sensitivity (span) calibration) in menu selection with nothing on the pan. (2) Press the [TARE] key. The value of the weight to be used for calibration flashes. (3) Place the calibration weight on the pan. (4) Press the [TARE] key when the stability mark illuminates after placing the weight. (5) Zero flashes on the display. (6) Remove the weight from the pan and press the [TARE] key when the stability mark illuminates. (7) “End” is displayed and then it changes to the weight display. CAUTION! The internal values of the balance are being revised while “End” is displayed. Do not turn off the power while “End” is displayed. [Setting the Piece Counting Mode] (1) Place a container on the pan and press the [TARE] key. (2) Select “Conv PCS” (piece counting settings) in menu selection. (3) The number of reference pieces of sample is displayed as “10”. Select the intended number of pieces by pressing the [MODE] key. The number changes in the following order each time the [MODE] key is pressed: 10 -> 20 -> 50 -> 100 -> 10... (4) Place the displayed number of sample pieces in the container while the number is displayed. (5) Press the [TARE] key when the stability mark illuminates after placing the sample pieces. (6) “SEt” is displayed and then it changes to the piece counting display with the piece counting mark (PCS) illuminating. CAUTION! The internal values of the balance are being revised while “SEt” is displayed. Do not turn off the power while “SEt” is displayed. [Setting the Percent Conversion Mode] (1) Place a container on the pan and press the [TARE] key. (2) Select “Conv %” (percentage conversion settings) in menu selection. (3) “100 %” is displayed. (4) Place the reference sample in the container. (5) Press the [TARE] key when the stability mark illuminates after placing the sample. (6) “SEt” is displayed and then it changes to the percentage display with the percentage mark (%) illuminating.. CAUTION! The internal values of the balance are being revised while “SEt” is displayed. Do not turn off the power while “SEt” is displayed