Download Directed Electronics S 580 E User guide
Transcript
2.7 Emergency Shutdown In the event of an emergency or malfunction, press the Emergency Machine Off (EMO) button. The EMO is the large red button located on the front panel of the dispensing system (Figure 2-3). Activating the EMO vents all pressure in the pneumatic system, de-energizes the servo power supply capacitors, and cuts power to all components except the computer and monitor. If the operator or technician is unable to reach the EMO button, the main power circuit breaker (Figure 2-3), which is located on the back of the system, can be used for emergency shutdown. TIP Front EMO Front View Main Power Circuit Breaker Rear View Figure 2-3 EMO/Main Power Circuit Breaker Locations 2.7.1 Emergency Shutdown Situations WARNING! In an emergency, failure to completely shut down power to the dispensing system can cause serious injury to the user and/or damage to the dispensing system. As a minimum, activate the EMO in the following situations: • If anyone is in immediate danger of being injured by moving parts, hazardous materials, or electrical shock. • If valuable dispensing system components or the workpieces are in danger of being damaged. This can include: - Physical damage to the dispensing valve or workpiece by unexpected dispensing head movement. - Electrical damage to the dispensing system. 16 Safety