Download Comtech EF Data SDM-100A Specifications
Transcript
Operation SDM-100A Satellite Modem SDM-100 "TYPE" VER: 14.7.4 FUNCTION SELECT MONITOR RAW BER CORRECTED BER CURRENT RAW BER NO DATA (if carrier not locked) CURRENT CORRECTED BER NO DATA (if carrier not locked) Low limit: based on performance. High limit: based on data/code rate. Low limit: based on performance. High limit: 1.0 E-12. RECEIVE SIGNAL EB/N0 CURRENT Eb/N0 NO DATA (if carrier not locked) Low limit: based on data rate. High limit: 16.0 dB. CURRENT RECEIVE LEVEL ( 25.0 to -60.0 dBm) Key: ACCESS TO SUBMENU CONDITIONAL OR OPTION-DEPENDENT Parameter Information Figure 3-19. Monitor (Type 1 Operation) 3.2.2.2 Monitor: Type 1 Operation When the Monitor level is entered, press [←] or [→] to select the desired monitor function. Each monitor function is displayed in real time as long as it is selected. RAW BER CORRECTED BER Eb/N0 RECEIVE SIGNAL Raw bit error rate Corrected bit error rate Energy (bit)/noise ratio Receive signal level Range: <m.m E-e to >m.m E-e Range: <m.m E-e to >m.m E-e Range: <mm.m to >mm.m Range: <-mm.m to >-mm.m (See Note) (See Note) (See Note) (See Note) Note: When the decoder loses lock, no data is available, and is so indicated. If data is over or under range, “<” or “>” will be indicated. 3–60 Rev. 0