SM Series Heat Pump 9. Remove and retain (2) horizontal blower support brackets by removing (4) screws in each. (Figure #56) Vertical Configurability | 19 11. Remove and retain vertical brackets from blower by removing (4) screws, (2) on each side of the blower. (Figure #58) Upper bracket contains two push-in rubber bump stops. Figure # 58 12. Reinstall vertical brackets in new orientation. (Figure #59) Figure # 56 10. Reinstall brackets removed in Step (9) on the same side of the unit as the blower outlet. (Figure #57) Ensure bracket with push-in rubber bump stops is installed in the top position. Figure # 59 13. Reinstall the blower assembly in the new desired location, using the existing holes. (Figure #60) Be aware of blower housing proximity to air side coil and potential for coil damage. Figure # 57 Figure # 60 Revised 08-13 6 720 220 406 (2013/9)