Download Siemens GC..M.. Installation manual
Transcript
Installing Primary AC Power Primary AC Power For Installation of AC Power for CE / ATEX units, refer to the Application Drawing Package, and page 17 concerning the special requirements for these systems which will be different from the information contained below. This section is documenting the requirements only for non-CE/ATEX units. The Maxum II operates from 100-130 VAC or 187-264 VAC 47-63Hz, single phase. WARNING Do not apply power to the unit until procedurally instructed to do so (this appears in a later procedure in this manual.) Installation personnel shall adhere to all AC power (Mains) specification requirements; see Application Drawing Package & Utility Diagram sheet. Failure to do so, and operating the equipment in a manner not specified, can impair the safety protection provided by the equipment. Fuses Fuses are located on the Power Entry Control Module located on the left sidewall of the Electronic Enclosure. Fuse requirements are (see page 22 for part numbers and locations): F1-ABH2: 16 Amperes, 115 VAC or 10 Amperes, 230 VAC F2-ABH1: 16 Amperes, 115 VAC or 10 Amperes, 230 VAC F3-FLT AC: 3.15 Amperes, 115 VAC or 230 VAC F4-LWH: 10 Amperes,115 VAC or 230 VAC F5-MWH: 6.3 Amperes,115 VAC or 230 VAC WARNING No substitutes should be used for the fuses noted above. Most of these are sand filled ceramic fuses with a very fast acting fuse to protect the heater relays. A fuse kit is available which contains all of the listed fuses on page 42. Power Consumption Typical maximum power consumption for the analyzer is 1700 Watts (single oven heater) during warmup, and averages 500 to 700 Watts during operation. In addition, a sampling system with a heated cabinet can consume from 30 to 2000 Watts, depending upon its particular arrangement. Refer to Application Drawing Package, Block Diagram Utility Connections sheet for the analyzer’s specific voltage and total power requirements (the wattage for the sampling system, if required, will also be given.) Installation of Components The following customer provided components are required for installation of primary AC power (if this is a CE / ATEX installation, then the user should refer to the Application Drawing Package for specifics): Primary AC Wire Size Customer AC power wiring recommended is three wire 12 AWG for 115 VAC and 14 AWG for 230 VAC with a hot, neutral, and ground. 18