GCOS 7 System Operator's Guide
Example
SO System
06
MC06
07
MC07
01
03
04
MC03
MC04
MS01
02
MS02
MSnn
Assume the device MS01 is accessible by 4 access paths through 2 Bi-PSI
controllers.
The DHW MS01 PATH=1 command gives the following result:
MC06.MS01
MC07.MS01
MC03.MS01
MC04.MS01
IN(READY)
IN(SPARE)
IN(READY)
IN(SPARE)
If a serious failure makes the first controller (MC06/MC07) unavailable, the
following messages are displayed:
(AV41)
(AV44)
(AV41)
(AV44)
hh.mm
hh.mm
hh.mm
hh.mm
MC06
MC06
MC07
MC07
PSI06 FAILED
OUT(BY SYSTEM)
PSI07 FAILED
OUT(BY SYSTEM)
The MS01 device remains accessible through the second controller (MC03/MC04).
A display of the MS01 device paths gives the following results:
MC06.MS01
MC07.MS01
MC03.MS01
MC04.MS01
OUT(CONTROLLER OUT)
OUT(CONTROLLER OUT)
IN(READY)
IN(SPARE)
The OLTDs can be used to diagnose the failed unit and the operator can use the
MDHW IN command to reinsert the unit after it has been repaired.
10-26