Download CAPL Callback Interface in CANoe
Transcript
CAPL Callback Interface in CANoe 4.1 Example how to use the CCI include files in an ECU simulation The following example shows how to use the CCI reference implementation corresponding to the ISO15765-2 TP on CAN implementation in “osek_tp.dll”: 1. Open the simulation setup and add a new Network Node. 2. From the context menu of the new node, choose “Configuration…” and select the tab “Common”. 3. Optionally assign a network node from your network description database (you may create such a database e.g. with the CANdb++ Editor): 4. Select the tab “Components” and confirm that the necessary TP DLL is already configured for this node based on the added database. If the database does not reference the TP DLL or you did not assign a network node from a database, you may add the DLL manually, choosing the respective DLL (here: “osek_tp.dll”) provided in the EXEC32-folder of your CANoe installation. In this case, the DLL is added to all assigned buses: Application Note AN-IND-1-012 7