OBLIGATIONS
Under Occupational Health and Safety legislation in each of Australia’s States and
Territories:
Employers must provide and maintain equipment and systems of work that are safe
and without risk to health.
Employers must provide suitable supervision and training to enable works to be carried
out safely.
Employees must take care for the health and safety of themselves and fellow workers
and co-operate with their employer whilst at work.
Building owners must supply a safe means of access for repetitive works such as
window cleaning.
SYSTEM PARAMETERS
Rope access is a manual system of providing access and which, by virtue of diversity of
equipment and specialized use techniques, allows access to many different locations,
such as:
Suspended works on building facades, towers, bridges, and many other structures.
Horizontal works such as under bridges, across roofs, etc.
Lead climbing works where the operator moves beyond the last point of connection.
Confined space works, recovery/access.
The access method relies upon the use of the following:
An access system, which allows the operator to safely access the required area. This
will often be a work rope, however on occasions, it may simply utilize elements of the
structure (e.g. truss members of a tower or bridge), the roof of a building (assuming
slope allows safe access – see AS/NZS 1891.4), or some other reliable form of access.
This is an alternative where fall arrest systems in accordance with AS/NZS 1891 series
are not a practical solution.
A mandatory safety or backup rope/system, which acts as a fall protection system in
the event of failure of the primary access system. This rope and associated hardware
must be used in such a way as to minimize fall distance and to ensure a maximum load
to the user or anchorage of 6kN in the event of a fall.
Two points of connection must be maintained at all times. There must always be a
physical connection to the backup or safety rope, and may also be a connection to the
work rope, the structure etc.
Rope access is used as either permanent systems, such as permanent façade access
systems or temporarily in “one off” locations such as carrying out an inspection on a bridge
or tower.
Whilst this Industry Code generally addresses the permanent use of rope access, it is
intended that the general principles apply to temporary uses and that the site controllers
will exercise judgments to deal with the differences over issues such as marking of anchor
points, documentation etc.
___________________________________________________________________________
ARAA Industry Code September 2005 Compiled by the ARAA (Vic) and ARAA (NSW)
4