4.4 Protections
The SunKeeper is fully protected against system faults
listed below. Recovery is automatic except where
noted below. Refer to section 3.0 for fault LED
indications.
Reverse Polarity Solar (LED OFF) – no charging,
disconnects solar module until wired with correct
polarity.
Reverse Polarity Battery (red blinking LED) – no
charging, displays fault until battery wired with correct
polarity.
Short Circuit Solar (LED OFF) – stops charging until
short clears or will enter Night stage (LED OFF) if fault
persists.
Charging Over-current (red blinking LED) –
charging current has exceeded SunKeeper current
rating; fully automatic recovery; retry every 10
seconds.
High Temperature Condition (red blinking LED) –
ambient temperature is too high; charging
automatically resumes when SunKeeper has cooled to
a safe temperature.
Temperature Sensor Failure (red blinking LED) –
detects a failure in the SunKeeper’s internal
temperature sensor or a disconnect of the Remote
Temperature Sensor (if used). Fault persists until the
problem is corrected.
15