Download 2 Switch Access
Transcript
Advanced Configuration Options: Link Up/Link Down Description: After port alarm is enabled, Link Up is displayed for a port connected properly. Link Down is displayed for a port disconnected or connected abnormally. DT-RING Alarm Options: Ring Open/Ring Close Description: After ring alarm is enabled, Ring Open is displayed for an open ring while Ring Close is displayed for a closed ring. 6.20 Port Traffic Alarm 6.20.1 Overview With the port traffic alarm function, the switch generates an alarm if the traffic rate of a port exceeds the specified threshold or a CRC error occurs. Caution: The traffic alarm function is based on a port. An alarm is generated only if the function is enabled on a port. The traffic alarm function is direction-specific. Incoming and outgoing traffic corresponds to different alarms. If a CRC error occurs, then a CRC error alarm is generated. 6.20.2 Web Configuration 1. Configure port traffic alarm, as shown in the following figure. Figure 120 Configuring Port Traffic Alarm 122