Download ACGS - HKFEMC
Transcript
Emergency stops shall be provided adjacent to each of the pump and fan unit. Local and remote control panels shall be provided for the water scrubber systems at location as shown on the Drawings. Local/remote selector switch shall be provided at the local panels for choice of control mode. In "remote" mode, the water scrubber system shall be started or stopped via manual push buttons at the remote control panel. The scrubber exhaust fan shall be interlocked with the recycle pumps’ operation such that it will not be operative unless the recycle pumps are operating. In "Local" mode, the fan and pumps shall be operated by means of start/stop buttons at the local control panel. The following minimum facilities shall be provided at the local control/starter panel:- t - Power on indication – green; - Local/remote selector; ra f - Recycle pumps sequence selector; - Start and stop push buttons for fan and pumps; - Hour run meters for fan; - Running (blue) and fault (red) indication for fan and pumps; - Ammeters for fan; D - Low level alarms (red) for each chemical tank; - Low level alarm (red) for the water scrubber chamber; and - No flow alarm (red) for the feed-in water pipe section. C1.19 WASHING FACILITIES FOR WASHABLE FILTER Where washable filters are provided, the Contractor shall provide one set of duplicate cleaning tanks (one to wash, one to rinse). These tanks shall be big enough to accommodate the various filters sizes provided, subject to the approval of the Architect or if the Contractor wishes several sets of tanks may be provided to accommodate the various filter sizes provided. The filter cleaning tanks shall be constructed of at least 1 mm thick stainless steel of AISI 316 and suitably stiffened around the top edges by continuous external turned over inverted "U" sections. The tanks shall be 0.4 m deep. They shall be supplied with 18 mm drain down cock for emptying but shall also have external handles to facilitate turning over to clear sludge. Section C1 Page 24 of 25 AC_GS 2012 Edition
Related documents
installation and start-up instructions
USER MANUAL - Websams Central Document Repository
Medical devices and eHealth solutions
Design and Applied Technology (Secondary 4 – 6)
EEGS - HKFEMC
USER MANUAL Financial Monitoring and Planning
Engine Models - Canaline Engines
LFGS - HKFEMC
KEGS - HKFEMC
MIGS - Hong Kong Federation of Electrical and Mechanical
Safety Policy - Gartner Refrigeration
Compendium of innovative health technologies for low