Download security and access control (dgp

Transcript
Partition 3: Options
Bold = Default setting
SECTION [513] : Partition 3 Options
Option
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
OFF
Partition 3 arms & disarms with Partition 1
N Disabled
Partition 3 arms & disarms with Partition 2
N Disabled
Switch to Stay Arming (if no delay zone opened) N Disabled
Partition 3 arms & disarms with Partition 4
N Disabled
Timed Auto-Arming
N Disabled
“No Movement” Auto-Arming
N Disabled
Arming method for auto arming
N Force Arming
Exit Delay termination
N Disabled
ON
N Enabled
N Enabled
N Enabled
N Enabled
N Enabled
N Enabled
N Stay Arming
N Enabled
SECTION [514] : Partition 3 Options
Option
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
Panic 1 (keys [1] and [3])
Panic 2 (keys [4] and [6])
Panic 3 (keys [7] and [9])
Panic 1 alarm type
Panic 2 alarm type
Panic 3 alarm type
Report Disarming Options
Future Use
OFF
N Disabled
N Disabled
N Disabled
N Report Only
N Report Only
N Report Only
N Always report disarming
N N/A
ON
N Enabled
N Enabled
N Enabled
N Audible Alarm
N Audible Alarm
N Fire Alarm
N Report disarming only after alarm
N N/A
OFF
N Disabled
N Disabled
N Disabled
N Disabled
N Disabled
N Disabled
N Disabled
ON
N Enabled
N Enabled
N Enabled
N Enabled
N Enabled
N Enabled
N Enabled
SECTION [515] : Partition 3 Options
Option
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
Bell Squawk upon Disarming
Bell Squawk upon Arming
Bell Squawk upon Auto-Arming
Bell Squawk during Exit Delay
Bell Squawk during Entry Delay
Bell Squawk upon Remote Arming/Disarming
Ring Back: bell squawk if disarmed after alarm
Ring Back: keypad beeps if disarmed after
alarm
N Disabled
N Enabled
SECTION [516]*: Partition 3 Options
Option
OFF
ON
[1]
One-Touch Regular Arming
N Disabled
N Enabled
[2]
One-Touch Stay Arming
N Disabled
N Enabled
[3]
One-Touch Instant Arming
N Disabled
N Enabled
[4]
One-Touch Force Arming
N Disabled
N Enabled
[5]
One-Touch Stay or Instant Disarming
N Disabled
N Enabled
[6]
One-Touch Bypass Programming
N Disabled
N Enabled
[7]
One-Touch Event Display
N Disabled
N Enabled
[8]
No Exit Delay when arming with remote control N Disabled
N Enabled
* If the keypad is assigned to more than one partition, the feature must be enabled in all the keypad’s partitions.
Digiplex DGP-48
- 21 -
Programming Guide