Download THERMAL IMAGER

Transcript
IRI 2010
THERMAL IMAGER
The IRI 2010 is an innovative thermal imager product offering
outstanding imaging and temperature measurement performance
together with the traditional Irisys features of flexibility, ease of use and
minimal cost of ownership.
Irisys has produced an imager which is ideal for maintenance
engineers and can be used to quickly find faults and identify failing
components to save money.
The IRI 2010 comes with a set of innovative features, making it a
unique product at its price:
• Image Fusion lets you view the world in visual, thermal or a blend
of both. Visual mode allows viewing of objects in a familiar manner,
with superimposed temperature measurement. The level of visual
and thermal image blending is adjustable from full visual to full
thermal via a blending of the two views.
• Hot and Cold Tracking: The camera can identify the hottest or
coldest point in the scene automatically. This assists the user in
fast diagnostics.
• Audible and Visual alarms: The camera can issue an alarm when a
point in the scene is outside a set temperature threshold value. The
thresholds can be hot or cold, or both.
• Software suite for off-line analysis and report generation.
The IRI 2010 is a low cost camera combining the features normally
found in high specification products with a robust and easy to use
feel. Typical applications for the IRI 2010 include:
•
•
•
•
Preventative Maintenance; electrical and mechanical.
Domestic & Industrial energy audits.
HVAC & Refrigeration inspection.
Troubleshooting and fault finding.
The IRI 2010 is the thermal imaging product designed for the mass
market.
“
Image fusion lets you view the
world in thermal image, visible image,
or a blend of both. A unique feature in
an imager at this price.
“
• Voice Annotation: The user can add voice messages to saved
images as an aide memoir for later report writing.
IRI 2010
TECHNICAL SPECIFICATION
PERFORMANCE
Field of view (FOV):
Spectral Response:
Sensitivity:
Detector:
Frame rate:
Focus Range:
20° x 20°
8µm to 14µm
≤0.3°C @ 30°C
47 x 47 pixel array
8Hz
0.5m to infinity
IMAGE STORAGE
Number:
Up to 1000 images on micro SD card supplied
DISPLAY
31/2” colour LCD with LED Backlight. 8 colour palettes. Mixed thermal
and visible images.
LASER POINTER
A built in Class 2 laser is supplied to highlight the centre of the thermal
image. (Aligned at 2 metres)
Beam Divergence
<0.2mrad
Maximum Output
<1mW
MEASUREMENT
Temperature range:
Radiometry:
-10°C to +350°C
Two moveable temperature measurement cursors
with temperature difference measurement.
Emissivity Correction: User selectable 0.10 to 1.00 in steps of 0.01 with
reflected ambient temperature compensation
Accuracy:
The greater of ±2°C or ±2% of reading in °C
IMAGER POWER SUPPLY
Battery:
Operation time:
AC operation:
Lithium-ion field rechargeable.
Up to 6 hours continuous operation
AC adaptor supplied
MECHANICAL
Housing:
Dimensions:
Weight:
Mounting:
Impact Resistant Plastic with over moulded soft
plastic and detachable handle
130mmx95mmx90mm (excluding handle)
0.70kg
Handheld & tripod mounting 1/4" BSW
OPTIONAL ACCESSORIES
• 12V car charger
• Light shade.
FEATURES
• Real-time image and temperature measurement display
• Visible/thermal/mixed image fusion
(100%, 75%, 50%, 25%, 0%)
• Simple operation
• Multiple temperature measurement
• Image browser
• Battery Charge indicator
• Lightweight
• Laser Pointer
• Auto hot/cold seeker
• Languages
• Thermal lens focus meter.
• LED illuminator for operation in dark environments
IRI 2010 Includes
IR Camera, Handle, Battery, AC Adaptor, USB cable,
Lanyard and lens cover tie, Quick start guide, Carrying
Case, CD with user manual and software (Analysis and
report writer)
Computer requirements (for PC software)
PC: IBM compatible PC with a minimum of: 300MHz
processor, MS Windows XP, VISTA, 128MB RAM
(see Irisys website for current list of operating systems
supported). Minimum Graphics resolution 16 bit colour
@ 1024 x 768 pixels, Minimum free hard disk space
requirement 10MB
ENVIRONMENT
Temp. operating range: -5°C to +45°C
Humidity: 10% to 90% non condensing
Temp. storage range: -20°C to +60°C
CE Mark (Europe)
IP rating: IP54
Operating temp for stated accuracy: 23 ºC
SETTINGS AND CONTROLS
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
On/Off soft power control
User selectable span & level control
Auto adjust span and level
4 preset thermal / visual alignment distances
Manual thermal / visual alignment
Readout in °C or °F
User selectable image integration
User selectable emissivity setting
User selectable reflected temperature
Two moveable temperature measurement cursors
Area analysis – 3 options
X-Y profiles
Isotherms
Text annotation
Voice annotation
Image capture, time and date
Visual/audio alarm high and low
© 2009 InfraRed Integrated Systems Limited (Irisys). No part of this publication may be reproduced without prior permission in
writing from Irisys. Whilst Irisys will endeavor to ensure that any data contained in this product information is correct, Irisys do
not warrant its accuracy or accept liability for any reliance on it. Irisys reserve the right to change the specification of the
products and descriptions in this data sheet without notice. Prior to ordering products please check with Irisys for current
specification details. This product may be protected by patents EP 0 853 237 B1, US 6,239,433 BI, US 5637871 and
JP3998788 other patents are pending. All brands and product names are acknowledged and may be trademarks or registered
trademarks of their respective holders.
InfraRed Integrated Systems Limited
Park Circle Tithe Barn Way Swan Valley Northampton NN4 9BG UK
Tel:
Fax:
Email:
Web site:
+44 (0) 1604 594 200
+44 (0) 1604 594 210
[email protected]
www.irisys.co.uk
February 2009