Chapter 2 Introduction to the Product
Chapter 2 Introduction to the Product
2.6 Technical Indications
Item
Item
Item Description
Input
Rated Voltage,
Frequency
Single/Three Phase 220 VAC, Three Phase 380VAC,
50Hz/60Hz
Allowable Voltage
Range
Effective Value of Voltage: 180~230V for Grade 220V;
320~460V for Grade 380V
Unbalance Value of Voltage: <3%; Frequency Fluctuation
Output
Rated Voltage
Frequency
Modulation System
Regulating Range
Three Phase: 0~ Input Voltage VAC
0
Magnetic Flux Vector Pulse-Width Modulation (PWM)
1
100
Digital Setting Max. Frequency
Frequency Accuracy Analogue Setting Max. Frequency
0.01%
0.2%
100% rated torque at 0.50Hz.
Torque Lifting
Automatic torque lifting: to lift the torque automatically
according to the output current.
Hand-operated torque lifting: Range: 1~30%
Slip Compensation
Setting range: 0~20%. The inverter output frequency
can be auto-regulated within this range according to the
motor load so as to reduce the speed variation of the
motor due to load fluctuation.
Acceleration/
Deceleration time
0.1~6,000 sec, which can be set in sequence.
Carrier frequency
1.0 13KHz
Braking
Function
Control Function
Digital Setting 0.01Hz;
Frequency Resolution Analogue Setting Max. Frequency 0.1%
Starting Torque
Automatic energysaving operation
Auto Voltage
Regulation
When the network voltage changes, it can regulate
PWM output automatically to maintain constant voltage.
Built-in PID
400Hz
Model G: Permanent if overload<110%; 1 min if
110%<overload<150%; 2 sec if 150%<overload<180%; instant if
overload 200%.
Model P: 1 min if overload<120%; 1 sec if
120%<overload<150%; instant if overload 180%.
Frequency setting
2.quadratic curve
-15-
This can form a convenient closed-loop control
system (CLCS), and is applicable to pressure control,
flow control and other process control.
operator panel control, external terminal control and
COM control
panel potentiometer setting, operator panel
setting,
external terminal up/down setting, analogue voltage
signal or external potentiometer setting, analogue
current signal setting, analogue nest setting and 485
COM setting.
Output signal
Forward/Reverse signal, multiple speed signal, failure
signal, reset signal and etc.
programmable open-collector output impedance, failure
signal output
Analogue output
terminal
This can realize the output of DC 0~10V signal,
frequency, current and other physical quantity.
Dynamic braking
With an external braking resistor, the maximum braking
torque may reach 100%.
This can be selected when the motor starts or stops with
the action frequency of 0~20Hz action voltage level of
0~20% and actuation time of 0~30 sec., and this value
can be set in sequence.
Input Signal
DC braking
Other Function
1.linear curve
V/F curve
Item Description
Auto optimize V/F curve according to load
fluctuation to realize energy-saving operation.
Operating instruction
Operation Function
Overload Capability
5%
Control Function
Table 2-2 Description Summary for Technical Indications
Protection Function
Other functions: Leap frequency, jog function, counter,
trace to rotating speed, instant shutdown restarting,
frequency upper/lower limitation,
acceleration/deceleration mode regulating, frequency
meter and voltmeter output, multiple speed/program
operation, two-wire/three-wire control, dipolar control,
multi-function input terminal selection, failure auto
reset and 485 COM.
Protection function: input open-phase protection, overcurrent protection, overload protection, undervoltage
protection, overheating protection and etc.