Download INVERTER
Transcript
Chapter 2 Introduction to the Product Chapter 2 Introduction to the Product 2.6 Technical Indications Item Item Item Description Input Rated Voltage, Frequency Single/Three Phase 220 VAC, Three Phase 380VAC, 50Hz/60Hz Allowable Voltage Range Effective Value of Voltage: 180~230V for Grade 220V; 320~460V for Grade 380V Unbalance Value of Voltage: <3%; Frequency Fluctuation Output Rated Voltage Frequency Modulation System Regulating Range Three Phase: 0~ Input Voltage VAC 0 Magnetic Flux Vector Pulse-Width Modulation (PWM) 1 100 Digital Setting Max. Frequency Frequency Accuracy Analogue Setting Max. Frequency 0.01% 0.2% 100% rated torque at 0.50Hz. Torque Lifting Automatic torque lifting: to lift the torque automatically according to the output current. Hand-operated torque lifting: Range: 1~30% Slip Compensation Setting range: 0~20%. The inverter output frequency can be auto-regulated within this range according to the motor load so as to reduce the speed variation of the motor due to load fluctuation. Acceleration/ Deceleration time 0.1~6,000 sec, which can be set in sequence. Carrier frequency 1.0 13KHz Braking Function Control Function Digital Setting 0.01Hz; Frequency Resolution Analogue Setting Max. Frequency 0.1% Starting Torque Automatic energysaving operation Auto Voltage Regulation When the network voltage changes, it can regulate PWM output automatically to maintain constant voltage. Built-in PID 400Hz Model G: Permanent if overload<110%; 1 min if 110%<overload<150%; 2 sec if 150%<overload<180%; instant if overload 200%. Model P: 1 min if overload<120%; 1 sec if 120%<overload<150%; instant if overload 180%. Frequency setting 2.quadratic curve -15- This can form a convenient closed-loop control system (CLCS), and is applicable to pressure control, flow control and other process control. operator panel control, external terminal control and COM control panel potentiometer setting, operator panel setting, external terminal up/down setting, analogue voltage signal or external potentiometer setting, analogue current signal setting, analogue nest setting and 485 COM setting. Output signal Forward/Reverse signal, multiple speed signal, failure signal, reset signal and etc. programmable open-collector output impedance, failure signal output Analogue output terminal This can realize the output of DC 0~10V signal, frequency, current and other physical quantity. Dynamic braking With an external braking resistor, the maximum braking torque may reach 100%. This can be selected when the motor starts or stops with the action frequency of 0~20Hz action voltage level of 0~20% and actuation time of 0~30 sec., and this value can be set in sequence. Input Signal DC braking Other Function 1.linear curve V/F curve Item Description Auto optimize V/F curve according to load fluctuation to realize energy-saving operation. Operating instruction Operation Function Overload Capability 5% Control Function Table 2-2 Description Summary for Technical Indications Protection Function Other functions: Leap frequency, jog function, counter, trace to rotating speed, instant shutdown restarting, frequency upper/lower limitation, acceleration/deceleration mode regulating, frequency meter and voltmeter output, multiple speed/program operation, two-wire/three-wire control, dipolar control, multi-function input terminal selection, failure auto reset and 485 COM. Protection function: input open-phase protection, overcurrent protection, overload protection, undervoltage protection, overheating protection and etc.