Download GLX Lighting PLB
Transcript
GLX LIGHTING POWER LED BEAM 56 NARROW Replacing the fuse Only replace the fuse by one of same type and rating. Before replacing the fuse, unplug the PLB-56N! Step 1: Open the fuse holder on the rear panel with a fitting screw driver. Step 2: Remove the old fuse from the fuse holder. Step 3: Install the new fuse in the fuse holder Step 4: Remount the fuse holder in the housing Should you need any spare parts, please use genuine parts. If the power supply cable of this device becomes damaged, it has to be replaces by a special power supply cable available at your dealer. Should you have further questions, please contact your dealer. Technical Specifications LIGHT SOURCE LED Illuminance @ 1 m Beam Angle 108 X 10mm (25 red, 25 green, 25 blue) 2550 lux @1meter 25° CONTROL & PROGRAMMING Data input Data output Data pin configuration Protocols Channels locking 3-pin XLR male socket locking 3-pin XLR female socket pin 1 shield, pin 2 (-), pin 3 (+) DMX-512 7 POWER Auto-switching power supply Power consumption Fuse 100V~240 VAC, 50/ 60Hz 22w 20mm 2A fast blow WEIGHT & DIMENSIONS Length Width Height Weight 210mm 220mm 230mm 1,2kg 8