Download User Manual - Davis Instruments
Transcript
Second Function: CURRENT HARMONIC MODE There are 52 measurement pages in this mode when an MR probe is connected and 51 measurement pages for all the other current probes. 1 2 3 4 Figure 4-17 ITEM 1. 2. 3. 4. 1st Page Rate of total current harmonic distortion (ATHD-F, also noted as ATHD) Root mean square value (Arms) 2nd Page Number of current harmonic considered 3rd Page Number of current harmonic considered The continuous harmonic component value Effective value of the harmonic component considered Current distortion factor *Percentage of the **Percentage of this continuous value effective value compared (ATHD-R, also noted as compared with the with the effective ADF) effective fundamental fundamental value. In this value example, the fundamental is 100% of itself # of page displayed / total # of pages *With an MR current probe connected **Without an MR current probe connected 42 Power Quality Analyzer Model 8220