HART Program User Manual Device Tag — Enter up to ten characters to identify the HART Point being defined in this screen. Any alphanumeric characters, including spaces, may be used. This field is a read/write field that displays or modifies the tag residing in the HART device. If you change the Device Tag for a multi-drop device, the new Device Tag in the Config Hart Point display is also changed. If you change or enter a new Device Tag, you must perform a Write Changes update. Refer to the Update Flag parameter on page 5-4. Device Num — Indicates the device number of the current Hart Pt Num. In the point-to-point mode, the device number is always 1. In multi-drop mode, the Device Number is a number from 1 to 5, depending on the number of HART devices configured on this channel. Hart Pt Num — When using the HART Interface Card program in a ROC306 or ROC312, this field displays the built-in analog input channel (1 to 3) to which this device is connected. When using the HART Interface Module program in a ROC312, ROC364, or FloBoss 407, this field displays the HART channel number within the module. Channel numbers increment by two for every HART module installed (to a maximum of 12), starting with the first rack location. For example: ♦ ♦ ♦ ♦ Module 1, Channel A = HART Point 1 Module 1, Channel B = HART Point 2 Module 2, Channel A = HART Point 3 Module 2, Channel B = HART Point 4 Soft Point — This enables the HART data to be mapped to one of the ROC Soft Points. A “0” entered into this field disables the writing of HART data to a Soft Point. Entering a number from 1 to 32 allows the HART data to be written to the corresponding Soft Point (1 to 32). Any number entered above 32 is invalid and will be reset to zero. See Appendix A for the mapping of HART data into a Soft Point. Update Counter — This counter updates every time a valid response is received from the HART device connected to this point. Primary Value — The Primary Value (process variable – PV) as read from the HART device. The PV is setup in the HART device and cannot be altered from the ROC. This is a measured quantity originating in the process such as pressure, temperature, flow, or a value derived from these like the HART Dynamic Variables. Primary Units — The units configured in the device for the Primary Value (PV) such as InH2O. Primary Current — The current of the HART device loop in milliamps. In point-to-point mode, this value varies between 4 and 20mA. In the multi-drop mode, this value is fixed typically at 4mA. Primary Percent — This field displays the HART device loop current as a percentage value. 5-2 Rev 3/99