Download Owner`s Manual - Forge Distribution

Transcript
J. Correct Baffle & Blanket Placement
INCORRECT POSITIONS
WARNING
Fire Risk
Improper baffle placement may cause:
• Overheating of firebox
• Overheating the chimney
Baffle must be placed properly (see instructions)
Replace baffle if damaged or missing.
NOTE: A missing, damaged or improperly positioned baffle
is dangerous and may cause damage and poor efficiency.
It will also void your warranty.
Ceramic Blanket and Baffle Board are NOT
in contact with the back of the firebox.
Note: This are generic drawings and may
not represent your specific model.
CORRECT POSITION
Ceramic Blanket
Back of Firebox
Ceramic Blanket is NOT in contact with the
back of the firebox and NOT even with the
Baffle Board in the front.
Ceramic Blanket
Back of Firebox
Baffle Board
Ceramic Blanket and Baffle Board MUST be
in contact with the back of the firebox and
even with each other in the front.
Figure 12.1 - Correct Baffle and Blanket Positions
Baffle Board
Ceramic Blanket is bunched up at the back
of the firebox and NOT even with the Baffle
Board in the front.
Figure 12.2 - Incorrect Baffle and Blanket Positions
Heatilator • ECO-WINS18 • 7065-132D • November 22, 2011
11