Download Reliability Bloc Diagram module
Transcript
• reading the results file. 6.2.1. Configuring the computations The computation configuration window can be accessed in two different ways: either via menu Data and Computations - Moca Data or via Data and Computations - Launch Moca 12 .... The difference between the two is that, in the second case, the configuration step is directly followed by the computation launch step. The configuration window which opens is called General Information: This configuration window is divided into five parts: 1. Title: allows you to give a title to the results file. 2. Default computation times for statistic states: • Iterate From A to B step C: the computations will be performed for values of t ranging from A to B with a step of C. • List of times: the computations will be performed for the values of t given in this list. • Computation made at: by default, computations are made immediatly after trantion triggering, but you can do computation at t-Epsilon (just before triggering), or at both. • Unit: default times unit is "hour". You can choose a unit that will be used for computation times. N.b. results are always in hours. 3. General: • Number of histories: Number of histories (NH) to be simulated (each history has a time t indicated below). • First random number: It is the seed of random number generator. • Maximum computation time (MT): The computations are stopped and the results are printed even if the requested number of histories has not been reached. User Manual 51 / 70 Version 31 March 2014